1
|
Hermans BP, Li WWL, Roozen EA, van Dort DIM, Vos S, van der Heide SM, van der Heijden EHFM, ten Broek RPG, van Goor H, Verhagen AFTM. Intrinsic pulmonary sealing, its mechanisms and impact on validity and translational value of lung sealant studies: a pooled analysis of animal studies. J Thorac Dis 2023; 15:4703-4716. [PMID: 37868902 PMCID: PMC10586971 DOI: 10.21037/jtd-23-180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 07/28/2023] [Indexed: 10/24/2023]
Abstract
Background No validated and standardized animal models of pulmonary air leakage (PAL) exist for testing aerostatic efficacy of lung sealants. Lack of negative control groups in published studies and intrinsic sealing mechanisms of healthy animal lungs might contribute to a translational gap, leading to poor clinical results. This study aims to address the impact of intrinsic sealing mechanisms on the validity of PAL models, and investigate the conditions required for an ovine model of PAL for lung sealant testing. Methods An ovine acute aerostasis model was developed, consisting of a bilateral thoracotomy with lesion creation, chest tube insertion and monitoring of air leaks using digital drains (≥80 minutes), under spontaneous respiration. Healthy mixed-breed adult female sheep were used and all in vivo procedures were performed under terminal anesthesia. Superficial parenchymal lesions were tested post-mortem and in vivo, extended lesions including bronchioles (deep bowl-shaped and sequential lung amputation lesions) were tested in vivo. Experiment outcomes include air leakage (AL), minimal leaking pressure (MLP) and histology. Results Two post-mortem (N=4 superficial parenchymal lesions) and 10 in vivo experiments (N=5 superficial parenchymal and N=16 lesions involving bronchioles) were performed. In contrast to the post-mortem model, superficial parenchymal lesions in vivo showed less air leak [mean flow ± standard deviation (SD): 760±693 vs. 42±33 mL/min, P=0.055]. All superficial parenchymal lesions in vivo sealed intrinsically within a median time of 20 minutes [interquartile range (IQR), 10-75 minutes]. Histology of the intrinsic sealing layer revealed an extended area of alveolar collapse below the incision with intra-alveolar hemorrhage. Compared to superficial parenchymal lesions in vivo, lesions involving bronchioles induced significantly higher air leak post-operatively (normalized mean flow ± SD: 459±221 mL/min, P=0.003). At termination, 5/9 (55.6%) were still leaking (median drain time: 273 minutes, IQR, 207-435 minutes), and intrinsic sealing for the remaining lungs occurred within a median of 115 minutes (IQR, 52-245 minutes). Conclusions Lung parenchyma of healthy sheep shows a strong intrinsic sealing mechanism, explained pathologically by an extended area of alveolar collapse, which may contribute to a translational gap in lung sealant research. A meaningful ovine model has to consist of deep lesions involving bronchioles of >⌀1.5 mm. Further research is needed to develop a standardized PAL model, to improve clinical effectiveness of lung sealants.
Collapse
Affiliation(s)
- Bob P. Hermans
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Wilson W. L. Li
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Edwin A. Roozen
- Department of General Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Daniël I. M. van Dort
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Shoko Vos
- Department of Pathology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Stefan M. van der Heide
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Erik H. F. M. van der Heijden
- Department of Pulmonology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Richard P. G. ten Broek
- Department of General Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Harry van Goor
- Department of General Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Ad F. T. M. Verhagen
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| |
Collapse
|
2
|
D'Hondt M, Roozen EA, Nuytens F, Bender J, Mottrie A, Bauwens K, Head SJ. NHS-POx-loaded patch versus fibrin sealant patch in a porcine robotic liver bleeding model. BMC Surg 2023; 23:257. [PMID: 37641071 PMCID: PMC10463878 DOI: 10.1186/s12893-023-02159-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 08/18/2023] [Indexed: 08/31/2023] Open
Abstract
BACKGROUND The management of bleeding is paramount to any surgical procedure. With the increased use of less invasive laparoscopic and robotic methods, achieving hemostasis can be challenging since the surgeons cannot manually apply hemostatic agents directly onto bleeding tissue. In this study, we assessed the use of a pliable hemostatic sealant patch comprising fibrous gelatin carrier impregnated with poly(2-oxazoline) (NHS-POx) for hemostasis in robotic liver resection in a porcine bleeding model. METHODS The NHS-POx-loaded patch (GATT-Patch), was first evaluated in a Feasibility Study to treat surgical bleeding in 10 lesions, followed by a Comparative Study in which the NHS-POx patch was compared to a standard-of-care fibrin sealant patch (TachoSil), in 36 lesions (superficial, resection, or deep injuries mimicking metastasectomies). For each lesion type, the NHS-POx and fibrin sealant patches were used in an alternating fashion with 18 lesions treated with NHS-POx and 18 with the fibrin patch. Animal preparation and surgical procedures were consistent across studies. The primary outcome was time to hemostasis (TTH) within 3 min for the Feasibility Study and within 5 min for the Comparative Study. RESULTS In the Feasibility Study, 8 of the 10 NHS-POx-treated lesions achieved hemostasis at 30 s and 3 min. In the Comparative Study, all 18 NHS-POx patch-treated lesions and 9 of the 18 fibrin sealant patch-treated lesions achieved hemostasis at 5 min. Median TTH with NHS-POx vs fibrin sealant patch was 30 vs 300 s (P < 0.001). CONCLUSIONS In this animal study, hemostasis during robotic liver surgery was achieved faster and more often with the NHS-POx loaded vs fibrin sealant patch.
Collapse
Affiliation(s)
- Mathieu D'Hondt
- Department of Digestive and Hepatobiliary/Pancreatic Surgery, AZ Groeninge Hospital, President Kennedylaan 4, 8500, Kortrijk, Belgium.
| | | | - Frederiek Nuytens
- Department of Digestive and Hepatobiliary/Pancreatic Surgery, AZ Groeninge Hospital, President Kennedylaan 4, 8500, Kortrijk, Belgium
| | | | | | | | | |
Collapse
|
3
|
Hermans BP, Li WWL, Roozen EA, van Dort DIM, Evers J, van der Heijden EHFM, van der Heide SM, van Goor H, Verhagen AFTM. Sealing effectiveness of a novel NHS-POx based patch: experiments in a dynamic ex vivo porcine lung. J Thorac Dis 2023; 15:3580-3592. [PMID: 37559645 PMCID: PMC10407471 DOI: 10.21037/jtd-22-1821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 05/12/2023] [Indexed: 08/11/2023]
Abstract
Background Sealants are used to prevent prolonged pulmonary air leakage (PAL) after lung resections (incidence 5.6-30%). However, clinical evidence to support sealant use is insufficient, with an unmet need for a more effective product. We compared a novel gelatin patch impregnated with functionalized polyoxazolines (NHS-POx) (GATT-Patch) to commercially available sealant products. Methods GATT-Patch Single/Double layers were compared to Progel®, Coseal®, Hemopatch® and TachoSil® in an ex vivo porcine lung model (first experiment). Based on these results, a second head-to-head comparison between GATT-Patch Single and Hemopatch® was performed. Air leakage (AL) was assessed in three settings using increasing ventilatory pressures (max =70 cmH2O): (I) baseline, (II) with 25 mm × 25 mm superficial pleural defect, and (III) after sealant application. Lungs floating on saline (37 ℃) were video recorded for visual AL assessment. Pressure and tidal volumes were collected from the ventilator, and bursting pressure (BP), AL and AL-reduction were determined. Results Per sealant 10 measurements were performed (both experiments). In the first experiment, BP was superior for GATT-Patch Double (60±24 cmH2O) compared to TachoSil® (30±11 cmH2O, P<0.001), Hemopatch® (33±6 cmH2O, P=0.006), Coseal® (25±13 cmH2O, P=0.001) and Progel® (33±11 cmH2O, P=0.005). AL-reduction was superior for GATT-Patch Double (100%±1%) compared to Hemopatch® (46%±50%, P=0.010) and TachoSil® (31%±29%, P<0.001), and also for GATT-Patch Single (100%±14%, P=0.004) and Progel (89%±40%, P=0.027) compared to TachoSil®. In the second experiment, GATT-Patch Single was superior regarding BP (45±10 vs. 40±6 cmH2O, P=0.043) and AL-reduction (100%±11% vs. 68%±40%, P=0.043) when compared to Hemopatch®. Conclusions The novel NHS-POx patch shows promise as a lung sealant, demonstrating elevated BP, good adhesive strength and a superior AL-reduction.
Collapse
Affiliation(s)
- Bob P. Hermans
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Wilson W. L. Li
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Edwin A. Roozen
- Department of General Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Daniël I. M. van Dort
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Jort Evers
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Erik H. F. M. van der Heijden
- Department of Pulmonology, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Stefan M. van der Heide
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Harry van Goor
- Department of General Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Ad F. T. M. Verhagen
- Department of Cardio-Thoracic Surgery, Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| |
Collapse
|
4
|
Roozen EA, Lomme RMLM, Calon NUB, Ten Broek RPG, van Goor H. Efficacy of a novel polyoxazoline-based hemostatic patch in liver and spleen surgery. World J Emerg Surg 2023; 18:19. [PMID: 36918896 PMCID: PMC10012589 DOI: 10.1186/s13017-023-00483-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 02/19/2023] [Indexed: 03/15/2023] Open
Abstract
BACKGROUND A new hemostatic sealant based on a N-hydroxy-succinimide polyoxazoline (NHS-POx) polymer was evaluated to determine hemostatic efficacy and long-term wound healing and adverse effects in a large animal model of parenchymal organ surgical bleeds. METHODS Experiment 1 included 20 pigs that were treated with two NHS-POx patch prototypes [a gelatin fibrous carrier (GFC) with NHS-POx and an oxidized regenerated cellulose (ORC) with poly(lactic-co-glycolic acid)-NHS-POx:NU-POx (nucleophilically activated polyoxazoline)], a blank gelatin patch (GFC Blank), TachoSil® and Veriset™ to stop moderate liver and spleen punch bleedings. After various survival periods (1-6 weeks), pigs were re-operated to evaluate patch degradation and parenchymal healing. During the re-operation, experiment 2 was performed: partial liver and spleen resections with severe bleeding, and hemostatic efficacy was evaluated under normal and heparinized conditions of the two previous prototypes and one additional NHS-POx patch. In the third experiment an improved NHS-POx patch (GATT-Patch; GFC-NHS-POx and added 20% as nucleophilically activated polyoxazoline; NU-POx) was compared with TachoSil®, Veriset™ and GFC Blank on punch bleedings and partial liver and spleen resections for rapid (10s) hemostatic efficacy. RESULTS NHS-POx-based patches showed better (GFC-NHS-POx 83.1%, ORC-PLGA-NHS-POx: NU-POx 98.3%) hemostatic efficacy compared to TachoSil® (25.0%) and GFC Blank (43.3%), and comparable efficacy with Veriset™ (96.7%) on moderate standardized punch bleedings on liver and spleen. All patches demonstrated gradual degradation over 6 weeks with a reduced local inflammation rate and an improved wound healing. For severe bleedings under non-heparinized conditions, hemostasis was achieved in 100% for Veriset™, 40% for TachoSil and 80-100% for the three NHS-POx prototypes; similar differences between patches remained for heparinized conditions. In experiment 3, GATT-Patch, Veriset™, TachoSil and GFC Blank reached hemostasis after 10s in 100%, 42.8%, 7.1% and 14.3%, respectively, and at 3 min in 100%, 100%, 14.3% and 35.7%, respectively, on all liver and spleen punctures and resections. CONCLUSIONS NHS-POx-based patches, and particularly the GATT-Patch, are fast in achieving effective hemostatic sealing on standardized moderate and severe bleedings without apparent long-term adverse events.
Collapse
Affiliation(s)
- Edwin A Roozen
- Department of Surgery, RadboudUMC, Geert Grooteplein 10, 6525 GA, Nijmegen, the Netherlands.,GATT Technologies BV, Nijmegen, the Netherlands
| | - Roger M L M Lomme
- Department of Surgery, RadboudUMC, Geert Grooteplein 10, 6525 GA, Nijmegen, the Netherlands.
| | - Nicole U B Calon
- Department of Surgery, RadboudUMC, Geert Grooteplein 10, 6525 GA, Nijmegen, the Netherlands
| | - Richard P G Ten Broek
- Department of Surgery, RadboudUMC, Geert Grooteplein 10, 6525 GA, Nijmegen, the Netherlands
| | - Harry van Goor
- Department of Surgery, RadboudUMC, Geert Grooteplein 10, 6525 GA, Nijmegen, the Netherlands
| |
Collapse
|
5
|
van Erk M, Lomme RMLM, Roozen EA, van Oirschot BAJA, van Goor H. A novel ex vivo perfusion-based mandibular pig model for dental product testing and training. BMC Oral Health 2023; 23:122. [PMID: 36823579 PMCID: PMC9948382 DOI: 10.1186/s12903-023-02794-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Accepted: 02/07/2023] [Indexed: 02/25/2023] Open
Abstract
BACKGROUND A translational ex vivo perfusion-based mandibular pig model was developed as an alternative to animal experiments, for initial assessment of biomaterials in dental and maxillofacial surgery and training. This study aimed to assess the face and content validity of the novel perfusion-based model. METHODS Cadaveric porcine heads were connected to an organ assist perfusion device for blood circulation and tissue oxygenation. Dental professionals and dental trainees performed a surgical procedure on the mandibula resembling a submandibular extraoral incision to create bone defects. The bone defects were filled and covered with a commercial barrier membrane. All participants completed a questionnaire using a 5-point Likert scale to assess the face and content validity of the model. Validation data between the two groups of participants were compared with Mann-Whitney U test. RESULTS Ten dental professionals and seven trainees evaluated the model for face and content validity. Participants reported model realism, with a mean face validity score of 3.9 ± 1.0 and a content validity of 4.1 ± 0.8. No significant differences were found for overall face and content validity between experts and trainees. CONCLUSION We established face and content validity in a novel perfusion-based mandibular surgery model. This model can be used as an alternative for animal studies evaluating new biomaterials and related dental and maxillofacial surgical procedural training.
Collapse
Affiliation(s)
- Machteld van Erk
- Department of Surgery (Route 618), Radboud University Medical Centre, PO Box 9101, 6500 HB, Nijmegen, The Netherlands.
| | - Roger M. L. M. Lomme
- grid.10417.330000 0004 0444 9382Department of Surgery (Route 618), Radboud University Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Edwin A. Roozen
- grid.10417.330000 0004 0444 9382Department of Surgery (Route 618), Radboud University Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| | - Bart A. J. A. van Oirschot
- grid.10417.330000 0004 0444 9382Department of Dentistry – Regenerative Biomaterials, Radboud University Medical Centre, Philips van Leydenlaan 25, 6525 EX Nijmegen, The Netherlands
| | - Harry van Goor
- grid.10417.330000 0004 0444 9382Department of Surgery (Route 618), Radboud University Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands
| |
Collapse
|
6
|
Roozen EA, Lomme RMLM, Calon NUB, Warlé MC, Van Goor H. Validity of a novel ex vivo porcine liver perfusion model for studying haemostatic products. Lab Anim 2022:236772221138398. [DOI: 10.1177/00236772221138398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Introduction We developed a novel normothermic ex vivo porcine liver perfusion model with whole blood in order to have alternatives for animal experiments in the research and development of new local haemostatic agents. This study aims to assess the construct and content validity of this model. Methods In this study we performed two ex vivo experiments using nine livers and one in vivo experiment using six female Norsvin Topigs pigs: (1) ex vivo liver perfusion for establishing physiological blood parameters of the perfused liver and controlled heparinization, (2) ex vivo liver perfusion with a surgical injury and (3) a surgical liver injury in anaesthetized pigs with and without heparin. Results Ex vivo coagulation parameters were comparable to in vivo with heparin. Blood gas values and metabolic parameters were comparable between ex vivo and in vivo with heparin, but significantly different compared with in vivo baseline, with the exception of (partial pressure of oxygen (PO2). Activated clotting time (ACT) values significantly differed depending on the heparin doses. The coagulation parameters fibrinogen, activated partial thromboplastin time, prothrombin time and ACT were rather constant during the 4 h ex vivo perfusion. Haemostatic efficacy of commercially available products was comparable between in vivo with heparin and the ex vivo liver perfusion experiment. Conclusion This novel ex vivo liver perfusion model demonstrates good construct and content validity for at least 4 h of perfusion. The model is an easily accessible, table-top, tunable and effective alternative for the in vivo testing of (new) haemostatic products on their haemostatic properties. Validité d'un nouveau modèle de perfusion hépatique porcin ex-vivo pour l'étude des produits hémostatiques Résumé
Collapse
Affiliation(s)
| | | | | | | | - Harry Van Goor
- Radboud University Medical Centre, Department of Surgery, Nijmegen, The Netherlands
| |
Collapse
|
7
|
Roozen EA, Warlé MC, Lomme RMLM, Félix Lanao RP, van Goor H. New polyoxazoline loaded patches for hemostasis in experimental liver resection. J Biomed Mater Res B Appl Biomater 2021; 110:597-605. [PMID: 34536065 PMCID: PMC9290804 DOI: 10.1002/jbm.b.34938] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 08/14/2021] [Accepted: 08/30/2021] [Indexed: 12/29/2022]
Abstract
A new cost‐effective NHS functionalized polyoxazoline (POx) loaded polymer with strong hemostatic properties has been developed. In this study, we investigate POx loaded hemostatic patches regarding hemostatic efficacy, local inflammatory reaction and wound‐healing, as compared to the non‐POx treated blanks and commercially available hemostatic products. Hundred and ten rats divided into 11 groups of 10 animals underwent partial liver lobe resection. Eight groups received experimental patches, two groups commercially available hemostatic patches (TachoSil® and Veriset™, positive controls), one group with gauzes (negative control). Each animal received twice a patch with a size 1.5 × 2.5 cm, on each partially resected lobe. Primary endpoint was time to hemostasis (TTH). The rats were sacrificed at different time points (1, 3, or 7 days) to measure local inflammatory response and early wound healing. Of the POx loaded patches, GFC NHS‐POx (TTH 20.4 s, p = .019) and GFC‐NHS‐POx1.5 (TTH 0.0 s, p = .003) showed significantly faster TTH compared to TachoSil® (TTH 95.4 s), and were comparable to Veriset™ (TTH 17.0 s). Three patches, GFC‐NHS‐POx 1.5 (TTH 0.0 s, p = .016), ORC NHS‐POx:NU‐POx (TTH 91.4 s, p = .033), and ORC‐PLGA NHS‐POx:NU‐POx (TTH 105.6 s, p = .04) had a lower TTH compared to their own blank carrier (TTH 74.9, 157.8, and 195.7 s, respectively). With regard to biocompatibility, all POx loaded patches showed results comparable to TachoSil® and Veriset™. NHS‐POx‐loaded hemostatic patch demonstrate fast and effective hemostasis, comparable or better than commercially available hemostatic patches, with similar early biocompatibility.
Collapse
Affiliation(s)
- Edwin A Roozen
- Department of Surgery, RadboudUMC, Nijmegen, The Netherlands
| | - Michiel C Warlé
- Department of Surgery, RadboudUMC, Nijmegen, The Netherlands
| | | | - Rosa P Félix Lanao
- Department of Surgery, RadboudUMC, Nijmegen, The Netherlands.,GATT Technologies BV, Nijmegen, The Netherlands
| | - Harry van Goor
- Department of Surgery, RadboudUMC, Nijmegen, The Netherlands
| |
Collapse
|