1
|
Burkhardt F, Schirmeister CG, Wesemann C, Baur L, Vach K, Nutini M, Licht EH, Metzger MC, Mülhaupt R, Spies BC. Dimensional accuracy and simulation-based optimization of polyolefins and biocopolyesters for extrusion-based additive manufacturing and steam sterilization. J Mech Behav Biomed Mater 2024; 153:106507. [PMID: 38503082 DOI: 10.1016/j.jmbbm.2024.106507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 03/04/2024] [Accepted: 03/12/2024] [Indexed: 03/21/2024]
Abstract
Polyolefins exhibit robust mechanical and chemical properties and can be applied in the medical field, e.g. for the manufacturing of dentures. Despite their wide range of applications, they are rarely used in extrusion-based printing due to their warpage tendency. The aim of this study was to investigate and reduce the warpage of polyolefins compared to commonly used filaments after additive manufacturing (AM) and sterilization using finite element simulation. Three types of filaments were investigated: a medical-grade polypropylene (PP), a glass-fiber reinforced polypropylene (PP-GF), and a biocopolyester (BE) filament, and they were compared to an acrylic resin (AR) for material jetting. Square specimens, standardized samples prone to warpage, and denture bases (n = 10 of each group), as clinically relevant and anatomically shaped reference, were digitized after AM and steam sterilization (134 °C). To determine warpage, the volume underneath the square specimens was calculated, while the deviations of the denture bases from the printing file were measured using root mean square (RMS) values. To reduce the warpage of the PP denture base, a simulation of the printing file based on thermomechanical calculations was performed. Statistical analysis was conducted using the Kruskal-Wallis test, followed by Dunn's test for multiple comparisons. The results showed that PP exhibited the greatest warpage of the square specimens after AM, while PP-GF, BE, and AR showed minimal warpage before sterilization. However, warpage increased for PP-GF, BE and AR during sterilization, whereas PP remained more stable. After AM, denture bases made of PP showed the highest warpage. Through simulation-based optimization, warpage of the PP denture base was successfully reduced by 25%. In contrast to the reference materials, PP demonstrated greater dimensional stability during sterilization, making it a potential alternative for medical applications. Nevertheless, reducing warpage during the cooling process after AM remains necessary, and simulation-based optimization holds promise in addressing this issue.
Collapse
Affiliation(s)
- Felix Burkhardt
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
| | - Carl G Schirmeister
- Freiburg Materials Research Center FMF and Institute for Macromolecular Chemistry, Albert-Ludwigs-University Freiburg, Stefan-Meier-Str. 21, 79104, Freiburg, Germany; Basell Sales & Marketing B.V., LyondellBasell Industries, Industriepark Höchst, 65926, Frankfurt a.M, Germany
| | - Christian Wesemann
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany
| | - Lukas Baur
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany
| | - Kirstin Vach
- Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Stefan-Meier-Str. 26, 79104, Freiburg, Germany
| | - Massimo Nutini
- Basell Poliolefine Italia Srl, LyondellBasell Industries, P. le Privato G. Donegani 12, 44122, Ferrara, Italy
| | - Erik H Licht
- Basell Sales & Marketing B.V., LyondellBasell Industries, Industriepark Höchst, 65926, Frankfurt a.M, Germany
| | - Marc C Metzger
- Medical Center - University of Freiburg, Center of Dental Medicine, Department of Oral and Maxillofacial Surgery, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany
| | - Rolf Mülhaupt
- Freiburg Materials Research Center FMF and Institute for Macromolecular Chemistry, Albert-Ludwigs-University Freiburg, Stefan-Meier-Str. 21, 79104, Freiburg, Germany; Sustainability Center Freiburg, Ecker-Str. 4, 79104, Freiburg, Germany
| | - Benedikt C Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany
| |
Collapse
|
2
|
Burkhardt F, Spies BC, Wesemann C, Schirmeister CG, Licht EH, Beuer F, Steinberg T, Pieralli S. Cytotoxicity of polymers intended for the extrusion-based additive manufacturing of surgical guides. Sci Rep 2022; 12:7391. [PMID: 35513701 PMCID: PMC9072356 DOI: 10.1038/s41598-022-11426-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 04/19/2022] [Indexed: 11/09/2022] Open
Abstract
Extrusion-based printing enables simplified and economic manufacturing of surgical guides for oral implant placement. Therefore, the cytotoxicity of a biocopolyester (BE) and a polypropylene (PP), intended for the fused filament fabrication of surgical guides was evaluated. For comparison, a medically certified resin based on methacrylic esters (ME) was printed by stereolithography (n = 18 each group). Human gingival keratinocytes (HGK) were exposed to eluates of the tested materials and an impedance measurement and a tetrazolium assay (MTT) were performed. Modulations in gene expression were analyzed by quantitative PCR. One-way ANOVA with post-hoc Tukey tests were applied. None of the materials exceeded the threshold for cytotoxicity (< 70% viability in MTT) according to ISO 10993-5:2009. The impedance-based cell indices for PP and BE, reflecting cell proliferation, showed little deviations from the control, while ME caused a reduction of up to 45% after 72 h. PCR analysis after 72 h revealed only marginal modulations caused by BE while PP induced a down-regulation of genes encoding for inflammation and apoptosis (p < 0.05). In contrast, the 72 h ME eluate caused an up-regulation of these genes (p < 0.01). All evaluated materials can be considered biocompatible in vitro for short-term application. However, long-term contact to ME might induce (pro-)apoptotic/(pro-)inflammatory responses in HGK.
Collapse
Affiliation(s)
- Felix Burkhardt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Benedikt C Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| | - Christian Wesemann
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.,Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité -Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität Zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197, Berlin, Germany
| | - Carl G Schirmeister
- Freiburg Materials Research Center FMF and Institute for Macromolecular Chemistry, Albert-Ludwigs-University Freiburg, Stefan-Meier-Str. 21, 79104, Freiburg, Germany.,Basell Sales & Marketing B.V., LyondellBasell Industries, Industriepark Höchst, 65926, Frankfurt, Germany
| | - Erik H Licht
- Basell Sales & Marketing B.V., LyondellBasell Industries, Industriepark Höchst, 65926, Frankfurt, Germany
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité -Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität Zu Berlin and Berlin Institute of Health, Assmanshauser Str. 4-6, 14197, Berlin, Germany
| | - Thorsten Steinberg
- Division of Oral Biotechnology, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| | - Stefano Pieralli
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center, Center for Dental Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany
| |
Collapse
|