1
|
Abushab KM, Herraiz JL, Vicente E, Cal-Gonzalez J, Espana S, Vaquero JJ, Jakoby BW, Udias JM. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners. IEEE Trans Nucl Sci 2016. [DOI: 10.1109/tns.2016.2527789] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
2
|
Abstract
In Positron Emission Tomography, there are several causes of quantitative inaccuracy, such as partial volume or spillover effects. The impact of these effects is greater when using radionuclides that have a large positron range, e.g. (68)Ga and (124)I, which have been increasingly used in the clinic. We have implemented and evaluated a local projection algorithm (LPA), originally evaluated for SPECT, to compensate for both partial-volume and spillover effects in PET. This method is based on the use of a high-resolution CT or MR image, co-registered with a PET image, which permits a high-resolution segmentation of a few tissues within a volume of interest (VOI) centered on a region within which tissue-activity values need to be estimated. The additional boundary information is used to obtain improved activity estimates for each tissue within the VOI, by solving a simple inversion problem. We implemented this algorithm for the preclinical Argus PET/CT scanner and assessed its performance using the radionuclides (18)F, (68)Ga and (124)I. We also evaluated and compared the results obtained when it was applied during the iterative reconstruction, as well as after the reconstruction as a postprocessing procedure. In addition, we studied how LPA can help to reduce the 'spillover contamination', which causes inaccurate quantification of lesions in the immediate neighborhood of large, 'hot' sources. Quantification was significantly improved by using LPA, which provided more accurate ratios of lesion-to-background activity concentration for hot and cold regions. For (18)F, the contrast was improved from 3.0 to 4.0 in hot lesions (when the true ratio was 4.0) and from 0.16 to 0.06 in cold lesions (true ratio = 0.0), when using the LPA postprocessing. Furthermore, activity values estimated within the VOI using LPA during reconstruction were slightly more accurate than those obtained by post-processing, while also visually improving the image contrast and uniformity within the VOI.
Collapse
Affiliation(s)
- J. Cal-González
- Grupo de Física Nuclear, Dpto. de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Spain
| | - S. C. Moore
- Division of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women’s Hospital. Boston, USA
| | - M.-A. Park
- Division of Nuclear Medicine, Department of Radiology, Harvard Medical School and Brigham and Women’s Hospital. Boston, USA
| | - J. L. Herraiz
- Grupo de Física Nuclear, Dpto. de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Spain
- Madrid-MIT M+Visión Consortium, Research Lab. of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
| | - J. J. Vaquero
- Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Spain
| | - M. Desco
- Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Spain
- Unidad de Medicina y Cirugía Experimental, Hospital General Universitario Gregorio Marañón, CIBERSAM, Madrid, Spain
| | - J. M. Udias
- Grupo de Física Nuclear, Dpto. de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Spain
| |
Collapse
|
3
|
Cal-González J, Moore SC, Park MA, Herraiz JL, Vaquero JJ, Desco M, Udias JM. Improved quantification for local regions of interest in preclinical PET imaging. Phys Med Biol 2015. [DOI: https://doi.org/10.1088/0031-9155/60/18/7127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
4
|
Abstract
Although current PET scanners are designed and optimized to detect double coincidence events, there is a significant amount of triple coincidences in any PET acquisition. Triple coincidences may arise from causes such as: inter-detector scatter (IDS), random triple interactions (RT), or the detection of prompt gamma rays in coincidence with annihilation photons when non-pure positron-emitting radionuclides are used (β(+)γ events). Depending on the data acquisition settings of the PET scanner, these triple events are discarded or processed as a set of double coincidences if the energy of the three detected events is within the scanner's energy window. This latter option introduces noise in the data, as at most, only one of the possible lines-of-response defined by triple interactions corresponds to the line along which the decay occurred. Several novel works have pointed out the possibility of using triple events to increase the sensitivity of PET scanners or to expand PET imaging capabilities by allowing differentiation between radiotracers labeled with non-pure and pure positron-emitting radionuclides. In this work, we extended the Monte Carlo simulator PeneloPET to assess the proportion of triple coincidences in PET acquisitions and to evaluate their possible applications. We validated the results of the simulator against experimental data acquired with a modified version of a commercial preclinical PET/CT scanner, which was enabled to acquire and process triple-coincidence events. We used as figures of merit the energy spectra for double and triple coincidences and the triples-to-doubles ratio for different energy windows and radionuclides. After validation, the simulator was used to predict the relative quantity of triple-coincidence events in two clinical scanners assuming different acquisition settings. Good agreement between simulations and preclinical experiments was found, with differences below 10% for most of the observables considered. For clinical scanners and pure positron emitters, we found that around 10% of the processed double events come from triple coincidences, increasing this ratio substantially for non-pure emitters (around 25% for (124)I and > 50% for (86)Y). For radiotracers labeled with (18)F we found that the relative quantity of IDS events in standard acquisitions is around 18% for the preclinical scanner and between 14 and 22% for the clinical scanners. For non-pure positron emitters like (124)I, we found a β(+)γ triples-to-doubles ratio of 2.5% in the preclinical scanner and of up to 4% in the clinical scanners.
Collapse
Affiliation(s)
- J Cal-González
- Grupo de Física Nuclear, Dpto. de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Spain
| | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Popota FD, Aguiar P, España S, Lois C, Udias JM, Ros D, Pavia J, Gispert JD. Monte Carlo simulations versus experimental measurements in a small animal PET system. A comparison in the NEMA NU 4-2008 framework. Phys Med Biol 2015; 60:151-62. [PMID: 25479341 DOI: 10.1088/0031-9155/60/1/151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
In this work a comparison between experimental and simulated data using GATE and PeneloPET Monte Carlo simulation packages is presented. All simulated setups, as well as the experimental measurements, followed exactly the guidelines of the NEMA NU 4-2008 standards using the microPET R4 scanner. The comparison was focused on spatial resolution, sensitivity, scatter fraction and counting rates performance. Both GATE and PeneloPET showed reasonable agreement for the spatial resolution when compared to experimental measurements, although they lead to slight underestimations for the points close to the edge. High accuracy was obtained between experiments and simulations of the system's sensitivity and scatter fraction for an energy window of 350-650 keV, as well as for the counting rate simulations. The latter was the most complicated test to perform since each code demands different specifications for the characterization of the system's dead time. Although simulated and experimental results were in excellent agreement for both simulation codes, PeneloPET demanded more information about the behavior of the real data acquisition system. To our knowledge, this constitutes the first validation of these Monte Carlo codes for the full NEMA NU 4-2008 standards for small animal PET imaging systems.
Collapse
Affiliation(s)
- F D Popota
- Unitat de Biofisica i Bioenginyeria, Universitat de Barcelona, Barcelona, Spain. Universidad de Pompeu Fabra, Barcelona, Spain
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Cal-González J, Lage E, Herranz E, Vicente E, Udias JM, Moore SC, Park MA, Dave SR, Parot V, Herraiz JL. Simulation of triple coincidences in PET. Phys Med Biol 2014. [DOI: https://doi.org/10.1088/0031-9155/60/1/117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
7
|
Abstract
Technical advances towards high resolution PET imaging try to overcome the inherent physical limitations to spatial resolution. Positrons travel in tissue until they annihilate into the two gamma photons detected. This range is the main detector-independent contribution to PET imaging blurring. To a large extent, it can be remedied during image reconstruction if accurate estimates of positron range are available. However, the existing estimates differ, and the comparison with the scarce experimental data available is not conclusive. In this work we present positron annihilation distributions obtained from Monte Carlo simulations with the PeneloPET simulation toolkit, for several common PET isotopes ((18)F, (11)C, (13)N, (15)O, (68)Ga and (82)Rb) in different biological media (cortical bone, soft bone, skin, muscle striated, brain, water, adipose tissue and lung). We compare PeneloPET simulations against experimental data and other simulation results available in the literature. To this end the different positron range representations employed in the literature are related to each other by means of a new parameterization for positron range profiles. Our results are generally consistent with experiments and with most simulations previously reported with differences of less than 20% in the mean and maximum range values. From these results, we conclude that better experimental measurements are needed, especially to disentangle the effect of positronium formation in positron range. Finally, with the aid of PeneloPET, we confirm that scaling approaches can be used to obtain universal, material and isotope independent, positron range profiles, which would considerably simplify range correction.
Collapse
Affiliation(s)
- J Cal-González
- Grupo de Física Nuclear, Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Spain
| | | | | | | | | | | | | |
Collapse
|
8
|
Cal-González J, Herraiz JL, España S, Corzo PMG, Vaquero JJ, Desco M, Udias JM. Positron range estimations with PeneloPET. Phys Med Biol 2013. [DOI: https://doi.org/10.1088/0031-9155/58/15/5127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
Abella M, Vicente E, Rodríguez-Ruano A, España S, Lage E, Desco M, Udias JM, Vaquero JJ. Misalignments calibration in small-animal PET scanners based on rotating planar detectors and parallel-beam geometry. Phys Med Biol 2012; 57:7493-518. [DOI: 10.1088/0031-9155/57/22/7493] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Janssen J, Alemán-Gómez Y, Reig S, Schnack HG, Parellada M, Graell M, Moreno C, Moreno D, Mateos-Pérez JM, Udias JM, Arango C, Desco M. Regional specificity of thalamic volume deficits in male adolescents with early-onset psychosis. Br J Psychiatry 2012; 200:30-6. [PMID: 22116979 DOI: 10.1192/bjp.bp.111.093732] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
BACKGROUND Thalamic volume deficits are associated with psychosis but it is unclear whether the volume reduction is uniformly distributed or whether it is more severe in particular thalamic regions. AIMS To quantify whole and regional thalamic volume in males with early-onset psychosis and healthy male controls. METHOD Brain scans were obtained for 80 adolescents: 46 individuals with early-onset psychosis with a duration of positive symptoms less than 6 months and 34 healthy controls. All participants were younger than 19 years. Total thalamic volumes were assessed using FreeSurfer and FSL-FIRST, group comparisons of regional thalamic volumes were studied with a surface-based approach. RESULTS Total thalamic volume was smaller in participants with early-onset psychosis relative to controls. Regional thalamic volume reduction was most significant in the right anterior mediodorsal area and pulvinar. CONCLUSIONS In males with minimally treated early-onset psychosis, thalamic volume deficits may be most pronounced in the anterior mediodorsal and posterior pulvinar regions, adding strength to findings from post-mortem studies in adults with psychosis.
Collapse
Affiliation(s)
- Joost Janssen
- Unidad de Medicina y Cirugía Experimental, Child and Adolescent Psychiatry Department, Hospital General Universitario Gregorio Marañón and Centro de Investigación Biomédica en Red de Salud Mental, CIBERSAM, Madrid, Spain.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Herraiz JL, España S, Cabido R, Montemayor AS, Desco M, Vaquero JJ, Udias JM. GPU-Based Fast Iterative Reconstruction of Fully 3-D PET Sinograms. IEEE Trans Nucl Sci 2011. [DOI: 10.1109/tns.2011.2158113] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
12
|
Malace SP, Paolone M, Strauch S, Albayrak I, Arrington J, Berman BL, Brash EJ, Briscoe B, Camsonne A, Chen JP, Christy ME, Chudakov E, Cisbani E, Craver B, Cusanno F, Ent R, Garibaldi F, Gilman R, Glamazdin O, Glister J, Higinbotham DW, Hyde-Wright CE, Ilieva Y, de Jager CW, Jiang X, Jones MK, Keppel CE, Khrosinkova E, Kuchina E, Kumbartzki G, Lee B, Lindgren R, Margaziotis DJ, Meekins D, Michaels R, Park K, Pentchev L, Perdrisat CF, Piasetzky E, Punjabi VA, Puckett AJR, Qian X, Qiang Y, Ransome RD, Saha A, Sarty AJ, Schulte E, Solvignon P, Subedi RR, Tang L, Tedeschi D, Tvaskis V, Udias JM, Ulmer PE, Vignote JR, Wesselmann FR, Wojtsekhowski B, Zhan X. Precise extraction of the induced polarization in the 4He(e,e'p)3H reaction. Phys Rev Lett 2011; 106:052501. [PMID: 21405386 DOI: 10.1103/physrevlett.106.052501] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2010] [Indexed: 05/30/2023]
Abstract
We measured with unprecedented precision the induced polarization P(y) in (4)He(e,e'p)(3)H at Q(2)=0.8 and 1.3 (GeV/c)(2). The induced polarization is indicative of reaction-mechanism effects beyond the impulse approximation. Our results are in agreement with a relativistic distorted-wave impulse approximation calculation but are overestimated by a calculation with strong charge-exchange effects. Our data are used to constrain the strength of the spin-independent charge-exchange term in the latter calculation.
Collapse
Affiliation(s)
- S P Malace
- University of South Carolina, Columbia, South Carolina 29208, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Riordan S, Abrahamyan S, Craver B, Kelleher A, Kolarkar A, Miller J, Cates GD, Liyanage N, Wojtsekhowski B, Acha A, Allada K, Anderson B, Aniol KA, Annand JRM, Arrington J, Averett T, Beck A, Bellis M, Boeglin W, Breuer H, Calarco JR, Camsonne A, Chen JP, Chudakov E, Coman L, Crowe B, Cusanno F, Day D, Degtyarenko P, Dolph PAM, Dutta C, Ferdi C, Fernández-Ramírez C, Feuerbach R, Fraile LM, Franklin G, Frullani S, Fuchs S, Garibaldi F, Gevorgyan N, Gilman R, Glamazdin A, Gomez J, Grimm K, Hansen JO, Herraiz JL, Higinbotham DW, Holmes R, Holmstrom T, Howell D, de Jager CW, Jiang X, Jones MK, Katich J, Kaufman LJ, Khandaker M, Kelly JJ, Kiselev D, Korsch W, LeRose J, Lindgren R, Markowitz P, Margaziotis DJ, Beck SMT, Mayilyan S, McCormick K, Meziani ZE, Michaels R, Moffit B, Nanda S, Nelyubin V, Ngo T, Nikolenko DM, Norum B, Pentchev L, Perdrisat CF, Piasetzky E, Pomatsalyuk R, Protopopescu D, Puckett AJR, Punjabi VA, Qian X, Qiang Y, Quinn B, Rachek I, Ransome RD, Reimer PE, Reitz B, Roche J, Ron G, Rondon O, Rosner G, Saha A, Sargsian MM, Sawatzky B, Segal J, Shabestari M, Shahinyan A, Shestakov Y, Singh J, Sirca S, Souder P, Stepanyan S, Stibunov V, Sulkosky V, Tajima S, Tobias WA, Udias JM, Urciuoli GM, Vlahovic B, Voskanyan H, Wang K, Wesselmann FR, Vignote JR, Wood SA, Wright J, Yao H, Zhu X. Measurements of the electric form factor of the neutron up to Q2=3.4 GeV2 using the reaction 3He(e,e'n)pp. Phys Rev Lett 2010; 105:262302. [PMID: 21231649 DOI: 10.1103/physrevlett.105.262302] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2010] [Indexed: 02/05/2023]
Abstract
The electric form factor of the neutron was determined from studies of the reaction 3He(e,e'n)pp in quasielastic kinematics in Hall A at Jefferson Lab. Longitudinally polarized electrons were scattered off a polarized target in which the nuclear polarization was oriented perpendicular to the momentum transfer. The scattered electrons were detected in a magnetic spectrometer in coincidence with neutrons that were registered in a large-solid-angle detector. More than doubling the Q2 range over which it is known, we find G(E)(n)=0.0236±0.0017(stat)±0.0026(syst), 0.0208±0.0024±0.0019, and 0.0147±0.0020±0.0014 for Q(2)=1.72, 2.48, and 3.41 GeV2, respectively.
Collapse
Affiliation(s)
- S Riordan
- Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Paolone M, Malace SP, Strauch S, Albayrak I, Arrington J, Berman BL, Brash EJ, Briscoe B, Camsonne A, Chen JP, Christy ME, Chudakov E, Cisbani E, Craver B, Cusanno F, Ent R, Garibaldi F, Gilman R, Glamazdin O, Glister J, Higinbotham DW, Hyde-Wright CE, Ilieva Y, de Jager CW, Jiang X, Jones MK, Keppel CE, Khrosinkova E, Kuchina E, Kumbartzki G, Lee B, Lindgren R, Margaziotis DJ, Meekins D, Michaels R, Park K, Pentchev L, Perdrisat CF, Piasetzky E, Punjabi VA, Puckett AJR, Qian X, Qiang Y, Ransome RD, Saha A, Sarty AJ, Schulte E, Solvignon P, Subedi RR, Tang L, Tedeschi D, Tvaskis V, Udias JM, Ulmer PE, Vignote JR, Wesselmann FR, Wojtsekhowski B, Zhan X. Polarization transfer in the 4He(e,e'p)3H reaction at Q2=0.8 and 1.3 (GeV/c)2. Phys Rev Lett 2010; 105:072001. [PMID: 20868031 DOI: 10.1103/physrevlett.105.072001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2010] [Indexed: 05/29/2023]
Abstract
Proton recoil polarization was measured in the quasielastic 4He(e,e'p)3H reaction at Q{2}=0.8 and 1.3 (GeV/c){2} with unprecedented precision. The polarization-transfer coefficients are found to differ from those of the 1H(e,e'p) reaction, contradicting a relativistic distorted-wave approximation and favoring either the inclusion of medium-modified proton form factors predicted by the quark-meson coupling model or a spin-dependent charge-exchange final-state interaction. For the first time, the polarization-transfer ratio is studied as a function of the virtuality of the proton.
Collapse
Affiliation(s)
- M Paolone
- University of South Carolina, Columbia, South Carolina 29208, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Janssen J, Reig S, Alemán Y, Schnack H, Udias JM, Parellada M, Graell M, Moreno D, Zabala A, Balaban E, Desco M, Arango C. Gyral and sulcal cortical thinning in adolescents with first episode early-onset psychosis. Biol Psychiatry 2009; 66:1047-54. [PMID: 19717139 DOI: 10.1016/j.biopsych.2009.07.021] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2009] [Revised: 07/10/2009] [Accepted: 07/19/2009] [Indexed: 10/20/2022]
Abstract
BACKGROUND Psychosis is associated with volumetric decreases of cortical structures. Whether these volumetric decreases imply abnormalities in cortical thickness, surface, or cortical folding is not clear. Due to differences in cytoarchitecture, cortical gyri and sulci might be differentially affected by psychosis. Therefore, we examined differences in gyral and sulcal cortical thickness, surface, folding, and volume between a minimally treated male adolescent population with early-onset first-episode psychosis (EOP) and a healthy control group, with surface-based morphometry. METHODS Magnetic resonance imaging brain scans were obtained from 49 adolescent EOP patients and 34 healthy control subjects. Subjects were younger than 18 years (age range 12 years-18 years), and EOP patients had a duration of positive symptoms of <6 months. RESULTS Early-onset first-episode psychosis was associated with local bilateral cortical thinning and volume deficits in both the gyri and sulci of the superior temporal cortex and the inferior, middle, medial, and superior prefrontal cortex. In the pars triangularis and opercularis cortex of patients, gyral cortical thickness was thinner, whereas sulcal thickness was not. Patients exhibited cortical thinning together with a decreased degree of cortical folding in the right superior frontal cortex. CONCLUSIONS Cortical thinning of both gyri and sulci seem to underlie most cortical volume deficits in adolescent patients with EOP. Except for the right superior frontal region, the degree of cortical folding was normal in regions showing decreased cortical thickness, suggesting that the process of cortical thinning in adolescent patients with EOP primarily takes place after the formation of cortical folds.
Collapse
Affiliation(s)
- Joost Janssen
- Department of Experimental Medicine and Surgery, Hospital General Universitario Gregorio Marañón, CIBERSAM, Spain.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
España S, Herraiz JL, Vicente E, Vaquero JJ, Desco M, Udias JM. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation. Phys Med Biol 2009; 54:1723-42. [PMID: 19242053 DOI: 10.1088/0031-9155/54/6/021] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.
Collapse
Affiliation(s)
- S España
- Grupo de Física Nuclear, Departmento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid, Spain
| | | | | | | | | | | |
Collapse
|
17
|
España S, Herraiz JL, Vicente E, Vaquero JJ, Desco M, Udias JM. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation. Phys Med Biol 2009. [DOI: https://doi.org/10.1088/0031-9155/54/6/021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
18
|
Caballero JA, Amaro JE, Barbaro MB, Donnelly TW, Maieron C, Udias JM. Superscaling in charged current neutrino quasielastic scattering in the relativistic impulse approximation. Phys Rev Lett 2005; 95:252502. [PMID: 16384453 DOI: 10.1103/physrevlett.95.252502] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2005] [Indexed: 05/05/2023]
Abstract
Superscaling of the quasielastic cross section in charged-current neutrino-nucleus reactions at energies of a few GeV is investigated within the framework of the relativistic impulse approximation. Several approaches are used to describe final-state interactions and comparisons are made with the plane-wave approximation. Superscaling is very successful in all cases. The scaling function obtained using a relativistic mean field for the final states shows an asymmetric shape with a long tail extending towards positive values of the scaling variable, in excellent agreement with the behavior presented by the experimental scaling function.
Collapse
Affiliation(s)
- J A Caballero
- Departamento de Física Atómica, Molecular y Nuclear, Universidad de Sevilla, 41080 Sevilla, Spain
| | | | | | | | | | | |
Collapse
|
19
|
Strauch S, Dieterich S, Aniol KA, Annand JRM, Baker OK, Bertozzi W, Boswell M, Brash EJ, Chai Z, Chen JP, Christy ME, Chudakov E, Cochran A, De Leo R, Ent R, Epstein MB, Finn JM, Fissum KG, Forest TA, Frullani S, Garibaldi F, Gasparian A, Gayou O, Gilad S, Gilman R, Glashausser C, Gomez J, Gorbenko V, Gueye PLJ, Hansen JO, Higinbotham DW, Hu B, Hyde-Wright CE, Ireland DG, Jackson C, de Jager CW, Jiang X, Jones C, Jones MK, Kellie JD, Kelly JJ, Keppel CE, Kumbartzki G, Kuss M, LeRose JJ, Livingston K, Liyanage N, Malov S, Margaziotis DJ, Meekins D, Michaels R, Mitchell JH, Nanda SK, Nappa J, Perdrisat CF, Punjabi VA, Ransome RD, Roché R, Rosner G, Rvachev M, Sabatie F, Saha A, Sarty A, Udias JM, Ulmer PE, Urciuoli GM, van den Brand JFJ, Vignote JR, Watts DP, Weinstein LB, Wijesooriya K, Wojtsekhowski B. Polarization transfer in the 4He(e-->,e'p-->)3H reaction up to Q2=2.6 (GeV/c)2. Phys Rev Lett 2003; 91:052301. [PMID: 12906589 DOI: 10.1103/physrevlett.91.052301] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2002] [Revised: 05/05/2003] [Indexed: 05/24/2023]
Abstract
We have measured the proton recoil polarization in the 4He(e-->,e(')p-->)4H reaction at Q(2)=0.5, 1.0, 1.6, and 2.6 (GeV/c)(2). The measured ratio of polarization transfer coefficients differs from a fully relativistic calculation, favoring the inclusion of a medium modification of the proton form factors predicted by a quark-meson coupling model. In addition, the measured induced polarizations agree reasonably well with the fully relativistic calculation indicating that the treatment of final-state interactions is under control.
Collapse
Affiliation(s)
- S Strauch
- Rutgers, The State University of New Jersey, Piscataway, New Jersey 08854, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Umino Y, Udias JM. Exchange current corrections to neutrino-nucleus scattering. I. Nuclear matter. Phys Rev C Nucl Phys 1995; 52:3399-3415. [PMID: 9970885 DOI: 10.1103/physrevc.52.3399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
|
21
|
|