1
|
Du K, Cai H, Park M, Wall TA, Stott MA, Alfson KJ, Griffiths A, Carrion R, Patterson JL, Hawkins AR, Schmidt H, Mathies RA. Multiplexed efficient on-chip sample preparation and sensitive amplification-free detection of Ebola virus. Biosens Bioelectron 2017; 91:489-496. [PMID: 28073029 DOI: 10.1016/j.bios.2016.12.071] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Revised: 12/26/2016] [Accepted: 12/30/2016] [Indexed: 12/23/2022]
Abstract
An automated microfluidic sample preparation multiplexer (SPM) has been developed and evaluated for Ebola virus detection. Metered air bubbles controlled by microvalves are used to improve bead-solution mixing thereby enhancing the hybridization of the target Ebola virus RNA with capture probes bound to the beads. The method uses thermally stable 4-formyl benzamide functionalized (4FB) magnetic beads rather than streptavidin coated beads with a high density of capture probes to improve the target capture efficiency. Exploiting an on-chip concentration protocol in the SPM and the single molecule detection capability of the antiresonant reflecting optical waveguide (ARROW) biosensor chip, a detection limit of 0.021pfu/mL for clinical samples is achieved without target amplification. This RNA target capture efficiency is two orders of magnitude higher than previous results using streptavidin beads and the limit of detection (LOD) improves 10×. The wide dynamic range of this technique covers the whole clinically applicable concentration range. In addition, the current sample preparation time is ~1h which is eight times faster than previous work. This multiplexed, miniaturized sample preparation microdevice establishes a key technology that intended to develop next generation point-of-care (POC) detection system.
Collapse
Affiliation(s)
- K Du
- Department of Chemistry, University of California at Berkeley, Berkeley, CA 94720, USA
| | - H Cai
- School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA
| | - M Park
- Department of Chemistry, University of California at Berkeley, Berkeley, CA 94720, USA
| | - T A Wall
- ECEn Department, Brigham Young University, 459 Clyde Building, Provo, UT 84602, USA
| | - M A Stott
- ECEn Department, Brigham Young University, 459 Clyde Building, Provo, UT 84602, USA
| | - K J Alfson
- Department of Virology and Immunology, Texas Biomedical Research Institute, 7620 NW Loop 410, San Antonio, TX 78227, USA
| | - A Griffiths
- Department of Virology and Immunology, Texas Biomedical Research Institute, 7620 NW Loop 410, San Antonio, TX 78227, USA
| | - R Carrion
- Department of Virology and Immunology, Texas Biomedical Research Institute, 7620 NW Loop 410, San Antonio, TX 78227, USA
| | - J L Patterson
- Department of Virology and Immunology, Texas Biomedical Research Institute, 7620 NW Loop 410, San Antonio, TX 78227, USA
| | - A R Hawkins
- ECEn Department, Brigham Young University, 459 Clyde Building, Provo, UT 84602, USA
| | - H Schmidt
- School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA.
| | - R A Mathies
- Department of Chemistry, University of California at Berkeley, Berkeley, CA 94720, USA.
| |
Collapse
|