1
|
Espona-Noguera A, Etxebarria-Elezgarai J, Saenz Del Burgo L, Cañibano-Hernández A, Gurruchaga H, Blanco FJ, Orive G, Hernández RM, Benito-Lopez F, Ciriza J, Basabe-Desmonts L, Pedraz JL. Type 1 Diabetes Mellitus reversal via implantation of magnetically purified microencapsulated pseudoislets. Int J Pharm 2019; 560:65-77. [PMID: 30742984 DOI: 10.1016/j.ijpharm.2019.01.058] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 01/24/2019] [Accepted: 01/25/2019] [Indexed: 01/13/2023]
Abstract
Microencapsulation of pancreatic islets for the treatment of Type I Diabetes Mellitus (T1DM) generates a high quantity of empty microcapsules, resulting in high therapeutic graft volumes that can enhance the host's immune response. We report a 3D printed microfluidic magnetic sorting device for microcapsules purification with the objective to reduce the number of empty microcapsules prior transplantation. In this study, INS1E pseudoislets were microencapsulated within alginate (A) and alginate-poly-L-lysine-alginate (APA) microcapsules and purified through the microfluidic device. APA microcapsules demonstrated higher mechanical integrity and stability than A microcapsules, showing better pseudoislets viability and biological function. Importantly, we obtained a reduction of the graft volume of 77.5% for A microcapsules and 78.6% for APA microcapsules. After subcutaneous implantation of induced diabetic Wistar rats with magnetically purified APA microencapsulated pseudoislets, blood glucose levels were restored into normoglycemia (<200 mg/dL) for almost 17 weeks. In conclusion, our described microfluidic magnetic sorting device represents a great alternative approach for the graft volume reduction of microencapsulated pseudoislets and its application in T1DM disease.
Collapse
Affiliation(s)
- A Espona-Noguera
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain
| | - J Etxebarria-Elezgarai
- BIOMICs-microfluidics Research Group, Microfluidics Cluster UPV/EHU, University of the Basque Country, Spain
| | - L Saenz Del Burgo
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain
| | - A Cañibano-Hernández
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain
| | - H Gurruchaga
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain
| | - F J Blanco
- INIBIC-Hospital Universitario La Coruña, La Coruña, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), La Coruña, Spain
| | - G Orive
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain; University Institute for Regenerative Medicine and Oral Implantology - UIRMI (UPV/EHU-Fundación Eduardo Anitua), BTI Biotechnology Institute, Vitoria-Gasteiz, Spain
| | - Rosa M Hernández
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain
| | - F Benito-Lopez
- AMMa LOAC Research Group, Microfluidics Cluster UPV/EHU, University of the Basque Country, Spain
| | - J Ciriza
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain
| | - L Basabe-Desmonts
- BIOMICs-microfluidics Research Group, Microfluidics Cluster UPV/EHU, University of the Basque Country, Spain; Basque Foundation of Science, IKERBASQUE, Spain.
| | - J L Pedraz
- NanoBioCel Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), Paseo de la Universidad 7, 01006 Vitoria-Gasteiz, Spain; Biomedical Research Networking Center in Bioengineering, Biomaterials, and Nanomedicine (CIBER-BBN), Vitoria-Gasteiz, Spain.
| |
Collapse
|
2
|
Tijero M, Díez-Ahedo R, Benito-Lopez F, Basabe-Desmonts L, Castro-López V, Valero A. Biomolecule storage on non-modified thermoplastic microfluidic chip by ink-jet printing of ionogels. Biomicrofluidics 2015; 9:044124. [PMID: 26339323 PMCID: PMC4552694 DOI: 10.1063/1.4928300] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Accepted: 07/29/2015] [Indexed: 05/07/2023]
Abstract
This paper reports an innovative technique for reagents storage in microfluidic devices by means of a one-step UV-photoprintable ionogel-based microarray on non-modified polymeric substrates. Although the ionogel and the ink-jet printing technology are well published, this is the first study where both are used for long-term reagent storage in lab-on-a-chip devices. This technology for reagent storage is perfectly compatible with mass production fabrication processes since pre-treatment of the device substrate is not necessary and inkjet printing allows for an efficient reagent deposition process. The functionality of this microarray is demonstrated by testing the release of biotin-647 after being stored for 1 month at room temperature. Analysis of the fluorescence of the ionogel-based microarray that contains biotin-647 demonstrated that 90% of the biotin-647 present was released from the ionogel-based microarray after pumping PBS 0.1% Tween at 37 °C. Moreover, the activity of biotin-647 after being released from the ionogel-based microarray was investigated trough the binding capability of this biotin to a microcontact printed chip surface with avidin. These findings pave the way for a novel, one-step, cheap and mass production on-chip reagents storage method applicable to other reagents such as antibodies and proteins and enzymes.
Collapse
Affiliation(s)
| | | | | | | | | | - A Valero
- CIC microGUNE , 20500 Arrasate-Mondragón, Spain
| |
Collapse
|
4
|
Basabe-Desmonts L, Ramstrom S, Meade G, O'Neill S, Riaz A, Lee LP, Ricco AJ, Kenny D. Single-step separation of platelets from whole blood coupled with digital quantification by interfacial platelet cytometry (iPC). Langmuir 2010; 26:14700-6. [PMID: 20108942 DOI: 10.1021/la9039682] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We report the efficient single-step separation of individual platelets from unprocessed whole blood, enabling digital quantification of platelet function using interfacial platelet cytometry (iPC) on a chip. iPC is accomplished by the precision micropatterning of platelet-specific protein surfaces on solid substrates. By separating platelets from whole blood using specific binding to protein spots of a defined size, iPC implements a simple incubate-and-rinse approach, without sample preparation, that enables (1) the study of platelets in the physiological situation of interaction with a protein surface, (2) the choice of the number of platelets bound on each protein spot, from one to many, (3) control of the platelet-platelet distance, including the possibility to study noninteracting single platelets, (4) digital quantification (counting) of platelet adhesion to selected protein matrices, enabling statistical characterization of platelet subpopulations from meaningfully large numbers of single platelets, (5) the study of platelet receptor expression and spatial distribution, and (6) a detailed study of the morphology of isolated single platelets at activation levels that can be manipulated. To date, we have demonstrated 1-4 of the above list. Platelets were separated from whole blood using iPC with fibrinogen, von Willebrand factor (VWF), and anti-CD42b antibody printed "spots" ranging from a fraction of one to several platelet diameters (2-24 μm). The number of platelets captured per spot depends strongly on the protein matrix and the surface area of the spot, together with the platelet volume, morphology, and activation state. Blood samples from healthy donors, a May-Hegglin-anomaly patient, and a Glanzmann's Thrombasthenia patient were analyzed via iPC to confirm the specificity of the interaction between protein matrices and platelets. For example, the results indicate that platelets interact with fibrinogen spots only through the fibrinogen receptor (αIIbβ3) and, relevant to diagnostic applications, platelet adhesion correlates strongly with normal versus abnormal platelet function. A critical function of platelets is to adhere to regions of damage on blood vessel walls; in contrast to conventional flow cytometry, where platelets are suspended in solution, iPC enables physiologically relevant platelet bioassays based on platelet/protein-matrix interactions on surfaces. This technology should be inexpensive to implement in clinical assay format, is readily integrable into fluidic microdevices, and paves the way for high-throughput platelet assays from microliter volumes of whole blood.
Collapse
Affiliation(s)
- L Basabe-Desmonts
- Biomedical Diagnostics Institute, Dublin City University, Dublin, Ireland
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Volcke C, Gandhiraman RP, Basabe-Desmonts L, Iacono M, Gubala V, Cecchet F, Cafolla AA, Williams DE. Protein pattern transfer for biosensor applications. Biosens Bioelectron 2009; 25:1295-300. [PMID: 19900799 DOI: 10.1016/j.bios.2009.10.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2009] [Revised: 09/24/2009] [Accepted: 10/13/2009] [Indexed: 10/20/2022]
Abstract
This paper presents a very simple, industrially scalable method for transferring a high-resolution, biologically active protein pattern from one substrate to another. We demonstrate the transfer of a protein pattern formed initially by microcontact printing from a silicon surface (to which this form of printing is applicable) onto a glass or polymer substrate, almost independently of the surface/bulk properties of the second substrate. A very thin, spin-coated layer of a sugar is used to preserve the structure and organization of proteins during the subsequent plasma deposition of a siloxane polymer, after which the protein pattern could simply be peeled off the silicon substrate and glued onto any other desired substrate.
Collapse
Affiliation(s)
- C Volcke
- Biomedical Diagnostics Institute (BDI), Dublin City University, Dublin, Ireland.
| | | | | | | | | | | | | | | |
Collapse
|