Elvira Ruiz G, Penafiel-Verdu P, Munoz-Esparza C, Martinez-Sanchez J, Sanchez-Munoz JJ, Garcia-Almagro F, Salar-Alcaraz M, Pastor-Perez FJ, Fernandez-Villa N, Veas-Porlan M, Martinez-Herrera M, Vazquez-Andres DJ, Jimenez-Aceituna A, Pascual-Figal DA, Garcia-Alberola A. Efficacy of left bundle branch area pacing in patients with indication for cardiac resynchronization therapy. Eur Heart J 2021. [DOI: 10.1093/eurheartj/ehab724.0400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Cardiac resynchronization therapy (CRT) with biventricular pacing has demonstrated clinical benefits in heart failure patients with left bundle branch block (LBBB) and ventricular dysfunction. Left bundle branch area pacing (LBBAP) results in a relatively short QRS duration (QRSd) with fast left ventricular activation and could be considered as an alternative to conventional CRT.
Purpose
The aim of the present study was to evaluate the feasibility and outcomes of LBBAP in patients with indications for CRT.
Methods
Consecutive patients with indications for CRT were included. LBBAP was performed via transventricular septal approach (1–3). We aimed to achieve a paced QRS with right bundle branch conduction delay morphology, a stimulus to peak left ventricular activation time (S-LVAT) <100ms and/or a QRSd ≤130ms. AV delay programming was individualized in patients in sinus rhythm, taking consideration of the AV conduction, programming the one that generated the shortest QRSd at rest. Rate adaptive AV was also activated in these patients. Pacing electrical and echocardiographic parameters were recorded at baseline and during follow-up.
Results
LBBAP was achieved in 19 of 21 (90.5%) patients with indication for CRT. Indications were heart failure with LBBB and left ventricular ejection fraction (LVEF) ≤35% in 8 (42%), AV node ablation or AV block with LVEF <50% and high expected RV pacing burden in 9 (47%), 1 pacing-induced cardiomyopathy and 1 patient with biventricular pacemaker malfunction (high LV capture threshold).
The mean follow-up was 4.6±1.7 months and the percentage of ventricular pacing was 93.4±13.9%. There were no device-related complications during this period.
LBBA capture threshold was 0.6±0.3V at 0.4ms at the implantation, and remained stable (0.7±0.1 V, p=0.17). The lead impedance and R-wave amplitude at implantation were 636±106 ohms and 13.4±6.8 mV, and 541±88 ohms and 13.0±5.1 mV during the follow-up (p<0.001 and p=0.27, respectively).
Mean S-LVAT was 85.5±13.9 ms, and mean QRSd was 122±9 ms, that remained stable during follow-up (122 vs 124 ms, p=0.21). In patients with LBBB, a significant narrowing of paced QRSd was achieved (160.9±16.7 vs. 123.9±9.7 ms, p<0.001).
Mean LVEF increased by 15.9%, from 35.4±8.9% at baseline to 51.3±9.8% at follow-up (p<0.001) in the overall population, and 14.5% (from 32.7±4.8% to 47.2±10.7%, p=0.001) in patients with LBBB.
After one month, estimated time for elective replacement was 11.9±0.4 years.
Conclusions
LBBPA was successfully achieved in 90.5% of the patients with indication for CRT, with good and stable pacing electrical parameters, long estimated battery longevity and relatively narrow QRS, and was associated with improvement in cardiac function. LBBAP may be considered as a first-line option for patients with indications for CRT.
Funding Acknowledgement
Type of funding sources: None.
Collapse
Affiliation(s)
- G Elvira Ruiz
- Hospital Universitario Virgen Arrixaca, Murcia, Spain
| | | | | | | | | | | | | | | | | | - M Veas-Porlan
- Hospital Universitario Virgen Arrixaca, Murcia, Spain
| | | | | | | | | | | |
Collapse
|
2
|
Muñoz-Esparza C, García-Molina E, Salar-Alcaraz M, Peñafiel-Verdú P, Sánchez-Muñoz JJ, Martínez Sánchez J, Cabañas-Perianes V, Valdés Chávarri M, García Alberola A, Gimeno-Blanes JR. Heterogeneous Phenotype of Long QT Syndrome Caused by the KCNH2-H562R Mutation: Importance of Familial Genetic Testing. ACTA ACUST UNITED AC 2015; 68:861-8. [PMID: 25819988 DOI: 10.1016/j.rec.2014.10.022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2014] [Accepted: 10/27/2014] [Indexed: 11/15/2022]
Abstract
INTRODUCTION AND OBJECTIVES Long QT syndrome is an inherited ion channelopathy that leads to syncope and sudden death. Because of the heterogeneous phenotype of this disease, genetic testing is fundamental to detect individuals with concealed long QT syndrome. In this study, we determined the features of a family with 13 carriers of the KCNH2-H562R missense mutation, which affects the pore region of the HERG channel. METHODS We identified the KCNH2-H562R mutation in a 65-year-old man with a prolonged QTc interval who had experienced an episode of torsade de pointes. Subsequently, a total of 13 mutation carriers were identified in the family. Carriers (age 48 [26] years; 46% males) underwent clinical evaluation, electrocardiography and echocardiography. RESULTS The mean (standard deviation) QTc in carriers was 493 (42) ms (3 [23%] showed normal QTc); 6 (46%) had symptoms (4, syncope; 1, sudden death; 1, aborted sudden death [proband]). While under treatment with beta-blockers, 11 of 12 carriers (92%) remained asymptomatic at 5 years of follow-up (1 patient required left cardiac sympathectomy). The QTc shortening with beta-blockers was 50 (37) ms. There was 1 sudden death in a patient who refused treatment. CONCLUSIONS Family study is essential in the interpretation of a genetic testing result. This article describes the heterogeneous and variable phenotype of a large family with the KCNH2-H562R mutation and highlights the role of genetic study for the appropriate identification of at-risk individuals who would benefit from treatment.
Collapse
Affiliation(s)
- Carmen Muñoz-Esparza
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Esperanza García-Molina
- Servicio de Análisis Clínicos, Hospital Clínico Universitario Virgen de la Arrixaca, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Mariela Salar-Alcaraz
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Pablo Peñafiel-Verdú
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Juan J Sánchez-Muñoz
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Juan Martínez Sánchez
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Valentín Cabañas-Perianes
- Servicio de Hematología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Mariano Valdés Chávarri
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Arcadio García Alberola
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain
| | - Juan R Gimeno-Blanes
- Servicio de Cardiología, Hospital Clínico Universitario Virgen de la Arrixaca, Universidad de Murcia, IMIB-Arrixaca, El Palmar, Murcia, Spain.
| |
Collapse
|
3
|
Peñafiel-Verdú P, Salar-Alcaraz M, Fernández-Fernández A, Martínez-Sánchez J, Sánchez-Muñoz JJ, García-Alberola A, Valdés-Chávarri M. Multiple interatrial electrical connection after heart transplantation. Pacing Clin Electrophysiol 2011; 35:e73-5. [PMID: 21281316 DOI: 10.1111/j.1540-8159.2011.03028.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
A 62-year-old woman who underwent heart transplantation 6 years later presented a regular atrial tachycardia. Electrophysiologic evaluation showed an atrial arrhythmia in the recipient atrium with 2:1 conduction to the donor atrium, with a confusing electroanatomical map. With the suspect of alternant conduction through two different breakthroughs, the map was split in two concordant maps, corresponding to two connections that were successfully ablated. Later on, a third connection was detected and therefore ablated.