1
|
Elamin MB, Chrouda A, Ali SMA, Alhaidari LM, Jabli M, Alrouqi RM, Renault NJ. Electrochemical sensor based on gum Arabic nanoparticles for rapid and in-situ detection of different heavy metals in real samples. Heliyon 2024; 10:e26364. [PMID: 38420384 PMCID: PMC10900941 DOI: 10.1016/j.heliyon.2024.e26364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 02/10/2024] [Accepted: 02/12/2024] [Indexed: 03/02/2024] Open
Abstract
The key solution to combat trace metal pollution and keep the environment, ecosystem, animals, and humans safe is earlier and rapid trace metal detection. For all these reasons, we propose in this work the design of a simple electrochemical sensor functionalized with green nanoparticles for electrochemical detection of the fourth most dangerous heavy metal ions namely copper, zinc, lead, and mercury. The green nanoparticles are fabricated by a one-step, consisting of reducing platinum nanoparticles by a natural gum Arabic polymer. To guarantee the success of these nanoparticles' design, the nanoparticles have been characterized by Fourier-transform infrared spectroscopy FTIR, and thermogravimetric TGA techniques. While, for the electrochemical characterization, we have adopted cyclic voltammetry CV and electrochemical impedance spectroscopy EIS to control different steps of surface modification, and the differential pulse anodic stripping DPAS was monitored to follow up the electrochemical detection of different heavy metals. Results have confirmed the good chemical and physical properties of the elaborated nanoparticles. As, the developed sensor showed a specific electrochemical response toward the heavy metal ions separately, with a lower limit of detection lower LOD than that recommended by the World Health Organization, in order of 9.6 ppb for Cu2+, 1.9 ppb for Zn2+, 0.9 ppb for Hg2+, and 4.2 ppb for Pb2+. Impressively, the elaborated sensor has demonstrated also high stability, outstanding sensitivity, and excellent analytical performance.In addition, the elaborated analytical tool has been successfully applied to the determination of various heavy metal ions in real samples, reflecting then its promising prospect in practical application.
Collapse
Affiliation(s)
- Manahil Babiker Elamin
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, 11952, Saudi Arabia
| | - Amani Chrouda
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, 11952, Saudi Arabia
| | | | - Laila M. Alhaidari
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, 11952, Saudi Arabia
| | - Mahjoub Jabli
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, 11952, Saudi Arabia
| | - Rahaf Mutlaq Alrouqi
- Department of Chemistry, Faculty of Science Al-Zulfi, Majmaah University, 11952, Saudi Arabia
| | - Nicole Jaffrezic Renault
- Institute of Analytical Sciences, UMR CNRS-UCBL-ENS 5280, 5 Rue la Doua, 69100, Villeurbanne, CEDEX, France
| |
Collapse
|
2
|
Zinoubi K, Chrouda A, Soltane R, Al‐Ghamdi YO, Garallah Almalki S, Osman G, Barhoumi H, Jaffrezic Renault N. Highly Sensitive Impedimetric Biosensor Based on Thermolysin Immobilized on a GCE Modified with AuNP‐decorated Graphene for the Detection of Ochratoxin A. ELECTROANAL 2020. [DOI: 10.1002/elan.202060247] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Khaoula Zinoubi
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences University of Monastir Monastir Tunisia
| | - Amani Chrouda
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences University of Monastir Monastir Tunisia
- Department of chemistry, College of Science at Zulfi Majmaah University Zulfi 11932 Saudi Arabia
- Institute of Analytical Sciences, UMR CNRS-UCBL 5280 5 Rue la Doua 69100 Villeurbanne Cedex France
| | - Raya Soltane
- Department Faculty of Sciences of Tunis Tunis El Manar University Tunisia
- Department of Basic Sciences, Adham University college Umm Al-Qura University Adham 21971 Saudi Arabia
| | - Youssef O. Al‐Ghamdi
- Department of chemistry, College of Science at Zulfi Majmaah University Zulfi 11932 Saudi Arabia
| | - Sami Garallah Almalki
- Department of Biology, College of Science Al-zulfi Majmaah University Al-Majmaah 11952 Saudi Arabia
| | - Gamal Osman
- Department of Biology, Faculty of Applied Sciences Umm Al-Qura University Makkah Saudi Arabia
- Research Laboratories Center, Faculty of Applied Science Umm Al-Qura University Mecca Saudi Arabia
- Agricultural Genetic Engineering Research Institute (AGERI), ARC 12619 Giza Egypt
| | - Houcine Barhoumi
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences University of Monastir Monastir Tunisia
- Institute of Analytical Sciences, UMR CNRS-UCBL 5280 5 Rue la Doua 69100 Villeurbanne Cedex France
| | - Nicole Jaffrezic Renault
- Institute of Analytical Sciences, UMR CNRS-UCBL 5280 5 Rue la Doua 69100 Villeurbanne Cedex France
| |
Collapse
|
3
|
Chrouda A, Zinoubi K, Soltane R, Alzahrani N, Osman G, Al-Ghamdi YO, Qari S, Al Mahri A, Algethami FK, Majdoub H, Jaffrezic Renault N. An Acetylcholinesterase Inhibition-Based Biosensor for Aflatoxin B 1 Detection Using Sodium Alginate as an Immobilization Matrix. Toxins (Basel) 2020; 12:E173. [PMID: 32168976 PMCID: PMC7150741 DOI: 10.3390/toxins12030173] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 03/02/2020] [Accepted: 03/05/2020] [Indexed: 01/08/2023] Open
Abstract
In this study, we investigated a novel aflatoxin biosensor based on acetylcholinesterase (AChE) inhibition by aflatoxin B1 (AFB1) and developed electrochemical biosensors based on a sodium alginate biopolymer as a new matrix for acetylcholinesterase immobilization. Electrochemical impedance spectroscopy was performed as a convenient transduction method to evaluate the AChE activity through the oxidation of the metabolic product, thiocholine. Satisfactory analytical performances in terms of high sensitivity, good repeatability, and long-term storage stability were obtained with a linear dynamic range from 0.1 to 100 ng/mL and a low detection limit of 0.1 ng/mL, which is below the recommended level of AFB1 (2 µg/L). The suitability of the proposed method was evaluated using the samples of rice supplemented with AFB1 (0.5 ng/mL). The selectivity of the AChE-biosensor for aflatoxins relative to other sets of toxic substances (OTA, AFM 1) was also investigated.
Collapse
Affiliation(s)
- Amani Chrouda
- Department of Chemistry, College of Science Al-Zulfi, Majmaah University, Al-Majmaah 11952, Saudi Arabia; (A.C.); (Y.O.A.-G.)
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, Monastir University, Monastir 5000, Tunisia; (K.Z.); (H.M.)
- Institute of Analytical Sciences, UMR CNRS-UCBL-ENS 5280, 5 Rue la Doua, 69100 Villeurbanne, CEDEX, France;
| | - Khouala Zinoubi
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, Monastir University, Monastir 5000, Tunisia; (K.Z.); (H.M.)
| | - Raya Soltane
- Faculty of Sciences of Tunis, Tunis El Manar University, El Manar, Tunis 1068, Tunis;
- Department of Basic Sciences, Adham University College, Umm Al-Qura University, Adham 21971, Saudi Arabia;
| | - Noof Alzahrani
- Department of Basic Sciences, Adham University College, Umm Al-Qura University, Adham 21971, Saudi Arabia;
| | - Gamal Osman
- Department of Biology, Faculty of Applied Sciences, Umm Al-Qura University, Makkah 21955, Saudi Arabia
- Research Laboratories Center, Faculty of Applied Science, Umm Al-Qura University, Mecca 21955, Saudi Arabia
- Agricultural Genetic Engineering Research Institute (AGERI), ARC, Giza 12915, Egypt
| | - Youssef O. Al-Ghamdi
- Department of Chemistry, College of Science Al-Zulfi, Majmaah University, Al-Majmaah 11952, Saudi Arabia; (A.C.); (Y.O.A.-G.)
| | - Sameer Qari
- Department of Biology, Aljumum University College, Umm Al-Qura University, Makkah Aljumum 21955, Saudi Arabia;
| | - Albandary Al Mahri
- Department of Biology, Faculty of Sciences and Arts, King Khalid University, Dhahran Aljanoub 61421, Saudi Arabia;
| | - Faisal K. Algethami
- Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia;
| | - Hatem Majdoub
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences, Monastir University, Monastir 5000, Tunisia; (K.Z.); (H.M.)
| | - Nicole Jaffrezic Renault
- Institute of Analytical Sciences, UMR CNRS-UCBL-ENS 5280, 5 Rue la Doua, 69100 Villeurbanne, CEDEX, France;
| |
Collapse
|
4
|
Tertiş M, Florea A, Adumitrăchioaie A, Cernat A, Bogdan D, Barbu-Tudoran L, Jaffrezic Renault N, Săndulescu R, Cristea C. Detection of Dopamine by a Biomimetic Electrochemical Sensor Based on Polythioaniline-Bridged Gold Nanoparticles. Chempluschem 2016; 82:561-569. [PMID: 31961589 DOI: 10.1002/cplu.201600539] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Indexed: 12/19/2022]
Abstract
A new biomimetic electrochemical sensor was developed for the detection of dopamine based on a glassy carbon electrode modified with electrochemically generated gold nanoparticles. The preparation of the polymer is simple and cost-effective, achieving the polymerization of thioaniline and generation of gold nanoparticles in a single step by cyclic voltammetry, in the presence of the target molecule, dopamine. After extraction, the imprinted polymer exhibits high sensitivity and selectivity for dopamine. Moreover, the developed imprinted polymer film allows the fast, direct detection of dopamine without the need of a redox mediator. The formation of a self-assembled monolayer of the monomer prior to electropolymerization ensures the adherence of the film onto the electrode surface, conferring good stability to the sensor (over two weeks). Cyclic voltammetry, electrochemical impedance spectroscopy, atomic force microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy were used for the complete characterization of the developed sensor, and differential pulse voltammetry was used for its testing.
Collapse
Affiliation(s)
- Mihaela Tertiş
- Analytical Chemistry Department, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Louis Pasteur St, 400349, Cluj-Napoca, Romania
| | - Anca Florea
- Analytical Chemistry Department, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Louis Pasteur St, 400349, Cluj-Napoca, Romania
| | - Alina Adumitrăchioaie
- Analytical Chemistry Department, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Louis Pasteur St, 400349, Cluj-Napoca, Romania
| | - Andreea Cernat
- Analytical Chemistry Department, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Louis Pasteur St, 400349, Cluj-Napoca, Romania
| | - Diana Bogdan
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat St, 400293, Cluj-Napoca, Romania
| | - Lucian Barbu-Tudoran
- National Institute for Research and Development of Isotopic and Molecular Technologies, 67-103 Donat St, 400293, Cluj-Napoca, Romania
| | - Nicole Jaffrezic Renault
- Institute of Analytical Sciences, UMR-CNRS 5280, University of Lyon, 5 La Doua St, 69100, Villeurbanne, France
| | - Robert Săndulescu
- Analytical Chemistry Department, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Louis Pasteur St, 400349, Cluj-Napoca, Romania
| | - Cecilia Cristea
- Analytical Chemistry Department, Iuliu Haţieganu University of Medicine and Pharmacy, 4 Louis Pasteur St, 400349, Cluj-Napoca, Romania
| |
Collapse
|
5
|
Nacer H, Afia L, Salghi R, Touzani R, Bouzenada L, Hammouti B, Renault NJ. Characterisation by electrochemical impedance spectroscopy of a pet membrane electrode based on zeolithe. Res Chem Intermed 2015. [DOI: 10.1007/s11164-013-1430-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Anh TM, Dzyadevych SV, Van MC, Renault NJ, Duc CN, Chovelon JM. Conductometric tyrosinase biosensor for the detection of diuron, atrazine and its main metabolites. Talanta 2012; 63:365-70. [PMID: 18969441 DOI: 10.1016/j.talanta.2003.11.008] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2003] [Revised: 10/23/2003] [Accepted: 11/05/2003] [Indexed: 10/26/2022]
Abstract
The determination of diuron, atrazine, desisopropylatrazine (DIA) and desethylatrazine (DEA) were investigated using conductometric tyrosinase biosensor. Tyrosinase was immobilised on the biosensor sensitive part by allowing it to mix with bovine serum albumin (BSA) and then cross-linking in saturated glutaraldehyde (GA) vapour for 30min. The determination of pollutants in a solution was performed by comparison of the output signal (i.e percentage of the enzymatic activity) of the biosensor before and after contact with pollutants. The measurement of the enzymatic activity was performed using 4-chlorophenol, phenol and catechol substrates and response times ranging from 1 to 5min were observed. A 4-chlorophenol substrate was used to detect pesticides. A 30min contact time of the biosensor in the pollutant solution was used. Under the experimental conditions employed, detection limits for diuron and atrazine were about 1ppb and dynamic range of 2.3-2330 and 2.15-2150ppb were obtained for diuron and atrazine, respectively. A relative standard deviation (n=3) of the output signal was estimated to be 5% and a slight drift of 1.5muSh(-1) was observed. The 90% of the enzyme activity was still maintained after 23 days of storage in a buffer solution at 4 degrees C.
Collapse
Affiliation(s)
- Tuan Mai Anh
- Laboratoire d'Application de la Chimie à l'Environnement, UMR CNRS 5634, Université Claude Bernard Lyon I, 43 Boulevard du 11 Novemvre 1918, Villeurbanne Cedex 69622, France; International Training Institute for Materials Science (ITIMS), Hanoi University of Technology, 1 Dai Co Viet, Hanoi, Viet Nam
| | | | | | | | | | | |
Collapse
|
7
|
Bourigua S, El Ichi S, Korri-Youssoufi H, Maaref A, Dzyadevych S, Jaffrezic Renault N. Electrochemical sensing of trimethylamine based on polypyrrole-flavin-containing monooxygenase (FMO3) and ferrocene as redox probe for evaluation of fish freshness. Biosens Bioelectron 2011; 28:105-11. [PMID: 21802279 DOI: 10.1016/j.bios.2011.07.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2011] [Accepted: 07/04/2011] [Indexed: 10/18/2022]
Abstract
Amperometric and impedimetric biosensor for detecting trimethylamine (TMA) which represents good parameters for estimating fish freshness has been developed. The biosensor is based on a conducting polypyrrole substituted with ferrocenyl, where flavin-containing monooxygenase 3 (FMO3) enzyme was immobilised by covalent bonding. FMO3 catalyzes the monooxygenation TMA to trimethylamine N-oxide (TMO). For catalysis FMO require flavin adenine (FAD) as a prosthetic group, NADPH as a cofactor and molecular oxygen as cosubstrate. Ferrocenyl group substituted on the polypyrrole matrix will serve as redox probe for monitoring the response of the biosensor to TMA. The construction of the biosensor was characterized by FT-IR, cyclic voltammetry and impedance measurements. Detection is done through the analysis of the current of oxidation signal of the ferrocenyl groups and compared to the measurement of impedance related to the electrical properties of the layers. Amperometric and impedimetric response were measured as a function of TMA concentration in range of 0.4 μgm L(-1)-80 μgm L(-1) (6.5 μmol L(-1)-1.5 mmol L(-1)). Amperometric measurements show a decrease in current response which is in correlation with the increase of the charge transfer resistance demonstrated by impedance. Calibration curve obtained by impedance spectroscopy shows a high sensitivity with a dynamic range from (0.4 μgm L(-1) to 80 μgm L(-1)). We demonstrated, using ferrocene as redox probe for catalytic reaction of FMO3, that high sensitivity and dynamic range was obtained. The biosensor was stable during 16 days. The biosensor shows high selectivity and its sensitivity to TMA in real samples was evaluated using fish extract after deterioration during storage.
Collapse
Affiliation(s)
- Sondes Bourigua
- Université de Lyon, Laboratoire des Sciences Analytiques, Université Claude Bernard, Lyon 1, 43 Boulevard du 11 Novembre 1918, 69622 Villeurbanne Cedex, France
| | | | | | | | | | | |
Collapse
|
8
|
McMurray AA, Ali Z, Kyselovik J, Mills CA, Renault NJ, Santha H, Strohhöfer C. A novel point of care diagnostic device: impedimetric detection of a biomarker in whole blood. Annu Int Conf IEEE Eng Med Biol Soc 2008; 2007:115-8. [PMID: 18001902 DOI: 10.1109/iembs.2007.4352236] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
There is an unmet medical need for a more reliable and earlier assessment of patients suspected of having a deep vein thrombosis. We describe a novel approach which is developing a highly reliable, accurate, portable and handheld prototype medical diagnostic device to improve radically the speed, accuracy and reliability with which DVT and related blood clotting conditions can be assessed. The device will measure whole blood concentration of D-dimer, a recognized biomarker of increased blood clotting activity, and through innovation in the development of a novel detection, measurement and reporting system, will offer the opportunity to use the test in the point of care setting. The device combines innovation in antibody bio-engineering for high specificity immunoassay-based diagnostics and nano/micro engineered impedimetric analysis electrodes incorporating a biocompatible polymer substrate with development of a disposable microfluidic manifold specifically enabling diagnostics at the point-of-first-contact.
Collapse
Affiliation(s)
- Amanda A McMurray
- Cenamps, The Centre of Excellence in Nano and Micro Photonic Systems, Fabriam Centre, Newcastle upon Tyne, NE28 9NZ, UK.
| | | | | | | | | | | | | |
Collapse
|
9
|
Renault NJ, Korri-Youssoufi H, Kyselovik J, Auger V, Errachid A, Mills CA, Strohhöfer C, Ali Z. Impedimetric microanalysis system for deep vein thrombosis point-of-care testing. Annu Int Conf IEEE Eng Med Biol Soc 2008; 2008:1856. [PMID: 19163047 DOI: 10.1109/iembs.2008.4649544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Affiliation(s)
- N J Renault
- Laboratory of Analytical Chemistry, Claude Bernard University, Lyon, France
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Anh TM, Dzyadevych SV, Prieur N, Duc CN, Pham T, Renault NJ, Chovelon JM. Detection of toxic compounds in real water samples using a conductometric tyrosinase biosensor. Materials Science and Engineering: C 2006. [DOI: 10.1016/j.msec.2005.10.025] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
11
|
Wang X, Dzyadevych SV, Chovelon JM, Renault NJ, Chen L, Xia S, Zhao J. Development of a conductometric nitrate biosensor based on Methyl viologen/Nafion® composite film. Electrochem commun 2006. [DOI: 10.1016/j.elecom.2005.11.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
|