1
|
Baldan N, Munegato G, Di Leo A, Lauro E, Morpurgo E, Pianigiani S, Briscolini D, Ferrara R, Fiscon V, Brolese A, De Manzoni G, Baldazzi G, Snidero D, Merigliano S, Ricci F, Laterza E, Merenda R, Gianesini R. Lessons learned from 227 biological meshes used for the surgical treatment of ventral abdominal defects. Hernia 2019; 24:57-65. [PMID: 30661179 DOI: 10.1007/s10029-019-01883-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Accepted: 10/25/2018] [Indexed: 01/07/2023]
Abstract
PURPOSE The advantages of biological meshes for ventral hernia repair are still under debate. Given the high financial cost, the proper indications for biological meshes should be clarified to restrict their use to properly selected patients. METHODS A retrospective database was instituted to register all cases of abdominal wall defect treated with biological meshes from 1/2010 to 3/2016. RESULTS A total of 227 patients (mean age: 64 years) whose ventral abdominal defects were reconstructed with a biological mesh were included in the study. Patients were divided according to the 2010 four-level surgical-site complication risk grading system proposed by the Ventral Hernia Working Group (VHWG): Grade 1 (G1, 12 cases), Grade 2 (G2, 68 cases), Grade 3 (G3, 112 cases), and Grade 4 (G4, 35 cases). The surgical site complication rate was higher in patients with one or more risk factors (33.6% vs 19% in patients with no risk factors) (P = 0.68). Statistically significant risk factors associated with the onset of one or more postoperative surgical site complications included: diabetes, coronary artery disease, immunosuppression, and obesity. Recurrence was more common in patients with surgical site complications and mainly associated with infection (38.9%) and wound necrosis (44.4%), and in cases of inlay positioning of the mesh (36%). CONCLUSIONS Due to their high costs, biological mesh should not be used in G1 patients. In infected fields (G4), they should only be used if no other surgical solution is feasible. There is a clear need to prospectively evaluate the performance of biological meshes.
Collapse
Affiliation(s)
- N Baldan
- Clinica Chirurgica 3, Azienda Ospedaliera Università di Padova, Padua, Italy.
| | - G Munegato
- Ospedale "S. Maria dei Battuti", Conegliano, TV, Italy
| | - A Di Leo
- Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - E Lauro
- Ospedale "S. Maria del Carmine" di Rovereto, Rovereto, TV, Italy
| | - E Morpurgo
- Ospedale di Camposampiero, Camposampiero, PD, Italy
| | - S Pianigiani
- Department of Industrial Engineering, Centre for Mechanics of Biological Materials, Università di Padova, Padua, Italy
| | - D Briscolini
- Clinica Chirurgica 3, Azienda Ospedaliera Università di Padova, Padua, Italy
| | | | - V Fiscon
- Ospedale di Cittadella, Cittadella, PD, Italy
| | - A Brolese
- Ospedale "Santa Chiara", Trento, Italy
| | - G De Manzoni
- Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - G Baldazzi
- ASST NORD MILANO Presidio Ospedaliero di Sesto San Giovanni, Sesto San Giovanni, MI, Italy
| | - D Snidero
- Ospedale di San Daniele del Friuli, San Daniele del Friuli, UD, Italy
| | - S Merigliano
- Clinica Chirurgica 3, Azienda Ospedaliera Università di Padova, Padua, Italy
| | - F Ricci
- Ospedale "S. Maria del Carmine" di Rovereto, Rovereto, TV, Italy
| | - E Laterza
- Ospedale di Legnago, Legnago, VR, Italy
| | - R Merenda
- Ospedale "SS. Giovanni e Paolo", Venice, Italy
| | | | | |
Collapse
|
2
|
Pianigiani S, Croce D, Pascale W, Innocenti B. Sensitivity analysis of the material properties of different soft-tissues: implications for a subject-specific knee arthroplasty. Muscles Ligaments Tendons J 2019. [DOI: 10.32098/mltj.04.2017.09] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- S. Pianigiani
- BEAMS Department, École polytechnique de Bruxelles, Université Libre de Bruxelles, Belgium
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - D. Croce
- Dipartimento di Chimica, Materiali ed Ingegneria Chimica “G. Natta”, Politecnico di Milano, Milan, Italy
| | - W. Pascale
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
| | - B. Innocenti
- BEAMS Department, École polytechnique de Bruxelles, Université Libre de Bruxelles, Belgium
| |
Collapse
|
3
|
Innocenti B, Larrieu JC, Lambert P, Pianigiani S. Automatic characterization of soft tissues material properties during mechanical tests. Muscles Ligaments Tendons J 2019. [DOI: 10.32098/mltj.04.2017.07] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- B. Innocenti
- BEAMS Department, Université Libre de Bruxelles, Brussels, Belgium
| | - J.-C. Larrieu
- BEAMS Department, Université Libre de Bruxelles, Brussels, Belgium
| | - P. Lambert
- BEAMS Department, Université Libre de Bruxelles, Brussels, Belgium
| | - S. Pianigiani
- BEAMS Department, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|