1
|
Botsford A, Tradi F, Loubet A, Tantawi S, Soulez G, Giroux MF, Faughnan ME, Gauthier A, Perreault P, Bouchard L, Holderbaum do Amaral R, Chartrand-Lefebvre C, Therasse E. Transarterial Embolization of Simple Pulmonary Arteriovenous Malformations: Long-Term Outcomes of 0.018-Inch Coils versus Vascular Plugs. J Vasc Interv Radiol 2024; 35:349-360. [PMID: 38013007 DOI: 10.1016/j.jvir.2023.11.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 10/24/2023] [Accepted: 11/17/2023] [Indexed: 11/29/2023] Open
Abstract
PURPOSE To compare the safety, effectiveness, and persistence rates of 0.018-inch coils with those of Amplatzer vascular plugs (AVPs; Abbott Vascular, Abbott Park, Illinois) for the treatment of pulmonary arteriovenous malformations (PAVMs) in response to a growing concern that 0.018-inch coil embolization would increase the long-term persistence rate. MATERIALS AND METHODS This is a retrospective, single-center study of a database (2002-2020) of 633 PAVM embolizations. Complex PAVMs and those not embolized with 0.018-inch coils or plugs were excluded. PAVM embolization material was classified into 4 groups: (a) 0.018-inch nonfibered coils (NFCs), (b) 0.018-inch fibered coils (FCs), (c) NFCs and FCs, or (d) plugs. Persistence was defined as flow through the PAVM on digital subtraction angiography (DSA) or as <30% diameter reduction of the aneurysmal sac on unenhanced computed tomography (CT). Kaplan-Meier analysis and Cox regression were used to assess PAVM's persistence-free survival. RESULTS A total of 312 PAVM embolizations with NFCs (43 PAVMs), FCs (127 PAVMs), NFCs and FCs (12 PAVMs), or plugs (130 PAVMs) in 109 patients (28% men; mean age = 49 years) were included. All PAVM embolizations were technically successful without any major adverse events. PAVM persistence-free survival rates at 10 years' follow-up were 40.8% versus 44.7% in the NFC and FC groups (P = .22) and 47.3% versus 81.0% in the 0.018-inch coil (NFC or FC) and plug groups (P < .0001), respectively. There were 0.43 (79/182) and 0.08 (10/130) re-embolization procedures per PAVM in the 0.018-inch coil and plug groups, respectively (P < .001). CONCLUSIONS PAVM embolization with 0.018-inch coils was safe, but persistence rate with PAVM embolization was significantly higher than that with plugs, with no significant differences between FCs and NFCs.
Collapse
Affiliation(s)
- Alexander Botsford
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada; Department of Radiology, QEII Health Sciences Centre, Halifax, Nova Scotia, Canada
| | - Farouk Tradi
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada; Assistance publique-hôpitaux de Marseille, Hôpital de la Timone, Service d'imagerie diagnostic et interventionnelle, Marseille, France; Laboratoire d'imagerie interventionnelle expérimentale (LIIE), Faculté de Médecine, CERIMED, Université Aix-Marseille Marseille, France
| | - Antoine Loubet
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada; Department of Radiology, Université de Montpellier, France
| | - Suhad Tantawi
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada
| | - Gilles Soulez
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada; Centre de recherche du CHUM (CRCHUM), Pavillon R, Montréal Quebec, Canada
| | - Marie-France Giroux
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada
| | - Marie E Faughnan
- Montreal HHT Centre, Division of Pneumology, Centre Hospitalier de l'Université de Montreal (CHUM), Montreal, Quebec, Canada; Division of Respirology, Department of Medicine, University of Toronto, Toronto, Ontario, Canada; St. Michael's Hospital and Li Ka Shing Knowledge Institute Toronto, Ontario, Canada
| | - Andréanne Gauthier
- Montreal HHT Centre, Division of Pneumology, Centre Hospitalier de l'Université de Montreal (CHUM), Montreal, Quebec, Canada
| | - Pierre Perreault
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada
| | - Louis Bouchard
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada
| | | | - Carl Chartrand-Lefebvre
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada
| | - Eric Therasse
- Department of Radiology, Centre Hospitalier de l'Université de Montréal (CHUM), Montréal, Quebec, Canada; Centre de recherche du CHUM (CRCHUM), Pavillon R, Montréal Quebec, Canada.
| |
Collapse
|
2
|
Nanni E, Tantawi S, Loo B, Snively E, Schulte R, Faddegon B, Pankuch M, Li Z, Dolgashev V, Ramos J. FLASH Modalities Track (Oral Presentations) 3D HIGH SPEED RF BEAM SCANNER FOR HADRON THERAPY OF CANCER. Phys Med 2022. [DOI: 10.1016/s1120-1797(22)01532-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
3
|
Trovati S, Borchard P, King GJ, Limborg CG, Loo BW, Maxim P, McCormick D, Nicolas LY, Schueler E, Tantawi S, Wang J, Wang L. TU-H-BRC-09: Validation of a Novel Therapeutic X-Ray Array Source and Collimation System. Med Phys 2016. [DOI: 10.1118/1.4957616] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
4
|
Whelan B, Keall P, Holloway L, Gierman S, Schmerge J, Tantawi S, Tremaine A, Trautwein A, Scott B, Fahrig R. TU-H-BRA-07: Design, Construction, and Installation of An Experimental Beam Line for the Development of MRI-Linac Compatible Electron Accelerator. Med Phys 2016. [DOI: 10.1118/1.4957629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
6
|
Bazalova M, Hardemark B, Hynning E, Dunning M, McCormick D, Liu M, Tantawi S, Dolgashev A, Koong A, Maxim P, Loo B. WE-C-108-01: JUNIOR INVESTIGATOR WINNER - Towards Radiation Therapy with Very High-Energy Electron Beams. Med Phys 2013. [DOI: 10.1118/1.4815524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
8
|
Tajima T, Haberkorn NF, Civale L, Schulze RK, Inoue H, Guo J, Dolgashev VA, Martin D, Tantawi S, Yoneda C, Moeckly B, Yung C, Proslier T, Pellin M, Matsumoto A, Watanabe E. Studies on thin film MgB2 for applications to RF structures for particle accelerators. ACTA ACUST UNITED AC 2012. [DOI: 10.1063/1.4712109] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
|