Orchard GE, Gabriel J, Shams M, Fernando P, Satoc J, Nwokie T, Ismail F, d'Amico C. Semi-automated standardisation of melanin bleaching procedures of heavily pigmented melanocytic lesions for immunohistochemical analysis on an automated platform. Br J Biomed Sci 2019; 76:172-177. [PMID: 31144600 DOI: 10.1080/09674845.2019.1624083] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Accepted: 05/17/2019] [Indexed: 10/26/2022]
Abstract
Background: The diagnosis of heavily pigmented melanocytic lesions is problematic. This is often compounded by lack of visibility of nuclear detail of tumour cells due to physical masking by melanin pigment. Similarly, there can be colour merging of chromogenic final reaction products with melanin, making an evidence of antigenic localisation problematic. There are a number of melanin bleaching techniques available for immunohistochemical assessments.Material and methods: All methods to date have involved the bleaching of melanin as a manually performed primary step before loading subsequently bleached slides onto automated immunohistochemical platforms. Here we define a semi-automated bleaching procedure that allows full integration on one of the most widely employed automated IHC staining platforms (Roche Ventana BenchMark Ultra). The bleaching protocol was defined on the BenchMark Ultra and involved the assessment of 24 histological cases of heavily pigmented malignant melanoma lesions (13 cutaneous and 11 metastatic) routinely fixed processed and paraffin wax embedded.Results: Completion of the bleaching was assessed on H&E preparations performed following the semi-automated bleaching step and employing the Roche Ventana BenchMark Ultra machine for 60 min at 42°C. Complete immunohistochemical staining was achieved on the automated platform within 5-6 h including the bleaching step. Results were consistent across all tissue evaluated.Discussion: This data provides evidence that the hydrogen peroxide bleaching procedure can be adapted for integration on one of the most widely employed automated IHC staining platforms and as a result, improve the efficiency and reproducibility of the technique.
Collapse
Affiliation(s)
- G E Orchard
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - J Gabriel
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - M Shams
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - P Fernando
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - J Satoc
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - T Nwokie
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - F Ismail
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| | - C d'Amico
- St. John's Histopathology, Tissue Sciences, Viapath Analytics, St. Thomas' Hospital, London, United Kingdom
| |
Collapse
|
2
|
Orchard GE, Shams M, Nwokie T, Fernando P, Bulut C, Quaye CJ, Gabriel J, Ramji Z, Georgaki A, Watt M, Cole Z, Stewart K, McTaggart V, Padayachy S, Long AM, Ogden A, Andrews C, Birchall A, Shams F, Neesam H, Haine N. A multicentre study of the precision and accuracy of the TruSlice and TruSlice Digital histological dissection devices. Br J Biomed Sci 2016; 73:163-167. [PMID: 27922431 DOI: 10.1080/09674845.2016.1233791] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND Five key factors enabling a good surgical grossing technique include a flat uniformly perpendicular specimen cutting face, appropriate immobilisation of the tissue specimen during grossing, good visualisation of the cutting tissue face, sharp cutting knives and the grossing knife action. TruSlice and TruSlice Digital are new innovative tools based on a guillotine configuration. The TruSlice has plastic inserts whilst the TruSlice Digital has an electronic micrometre attached: both features enable these dissection factors to be controlled. The devices were assessed in five hospitals in the UK. MATERIAL AND METHODS A total of 267 fixed tissue samples from 23 tissue types were analysed, principally the breast (n = 32) skin (30), rectum (28), colon (27) and cervix (17). Precision and accuracy were evaluated by measuring the defined thickness, and the consistency of achieving the defined thickness of tissue samples taken respectively. Both parameters were expressed as a total percentage of compliance for the cohort of samples accessed. RESULTS Overall, the mean (standard deviation) score for precision was 81 (11) % whilst the accuracy score was 82 (11) % (both p < 0.05, chi-squared test), although this varied with type of tissue. Accuracy and precision were strongly correlated (rp = 0.83, p < 0.001). CONCLUSION The TruSlice Digital devices offer an assured precision and accuracy performance which is reproducible across an assortment of tissue types. The use of a micrometre to set tissue slice thickness is innovative and should comply with laboratory accreditation requirements, alleviating concerns of how to tackle issues such as the 'measurement of uncertainty' at the grossing bench.
Collapse
Affiliation(s)
- G E Orchard
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - M Shams
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - T Nwokie
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - P Fernando
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - C Bulut
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - C J Quaye
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - J Gabriel
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - Z Ramji
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - A Georgaki
- a Viapath, St John's Institute of Dermatology , St. Thomas' Hospital , London , UK
| | - M Watt
- b Crosshouse Hospital , Kilmarnock , UK
| | - Z Cole
- b Crosshouse Hospital , Kilmarnock , UK
| | - K Stewart
- b Crosshouse Hospital , Kilmarnock , UK
| | | | - S Padayachy
- c Southampton General Hospital , Southampton , UK
| | - A M Long
- c Southampton General Hospital , Southampton , UK
| | - A Ogden
- c Southampton General Hospital , Southampton , UK
| | - C Andrews
- d Heartlands Hospital , Birmingham , UK
| | - A Birchall
- e Wythenshawe Hospital , Manchester , UK
| | - F Shams
- f Barts and the London School of Medicine, Queen Mary University of London , London , UK
| | | | - N Haine
- g CellPath Ltd. , Powys , UK
| |
Collapse
|
3
|
Orchard GE, Shams M, Nwokie T, Bulut C, D'Amico C, Gabriel J, Ramji Z, Georgaki A, Neichcial A, Shams F, Neesam H, Haine N, Brewer C. Development of new and accurate measurement devices (TruSlice and TruSlice Digital) for use in histological dissection: an attempt to improve specimen dissection precision. Br J Biomed Sci 2016; 72:140-5. [DOI: 10.1080/09674845.2015.11666811] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
4
|
Orchard GE, Torres J, Poirier A, Sounthararajah R, Webster J, Notini L, Hacker L, Ismail F, Nwokie T, Humphrey P, Spigler E, Missaghian-Cully S, Brewer C, Meredith-Jones A. Investigation into a new softening agent for use on formalin-fixed, paraffin wax-embedded tissue. Br J Biomed Sci 2009; 66:63-6. [PMID: 19637645 DOI: 10.1080/09674845.2009.11730246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The use of tissue softening agents to improve microtomy of keratotic tissues is employed widely. Many of these softeners contain hazardous constituents such as phenol. In this study, the use of non-ionic surfactants or non-toxic ingredients are investigated with the aim of creating a new softening agent. The new agent should be more effective in facilitating the sectioning of hardened tissue while reducing toxicity and complications associated with sectioning hard tissue compared to a commercially available phenol-based formulation. Four formulations are compared against the commercial product for their capability to section routinely processed paraffin-embedded tissue under standard operating procedure parameters. The trial formulations were shown to be fast acting and enabled improved serial sectioning of hard keratotic tissue in nearly all the cases tested. There was no evidence of adverse staining using either tinctorial or immunohistochemical methods. The new formulations had advantages over the commercially available solutions, improving on the number and quality of sections attainable from the tissue blocks, as well as offering a composition less toxic than phenol-based products.
Collapse
Affiliation(s)
- G E Orchard
- St. John's Histopathology Department, St. Thomas' Hospital, London SE 7EH, UK.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|