Garcia MM, Oliveira TR, Papoti D, Chaim KT, Otaduy MCG, Erni D, Zylka W. Experimental and numerical investigations of a small animal coil for ultra-high field magnetic resonance imaging (7T). Current Directions in Biomedical Engineering 2019. [DOI: 10.1515/cdbme-2019-0132] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
The purpose of this work was to develop and investigate a radiofrequency (RF) coil to perform image studies on small animals using the 7T magnetic resonance imaging (MRI) system, installed in the imaging platform in the autopsy room (Portuguese acronym PISA), at the University of Sao Paulo, Brazil, which is the unique 7T MRI scanner installed in South America. Due to a high demand to create new specific coils for this 7T system, it is necessary to carefully assess the distribution of electromagnetic (EM) fields generated by the coils and evaluate the patient/object safety during MRI procedures. To achieve this goal 3D numerical methods were used to design and analyse a 8-rungs transmit/receive linearly driven birdcage coil for small animals. Calculated magnetic field (B1) distributions generated by the coil were crosschecked with measured results, indicating good confidence in the simulated results. Electric field results were post-processed and predictions of local specific absorption rate (SAR) values were achieved for a spherical phantom filled with muscle-like tissue, indicating that the sample would not suffer any unsafe deposition of energy. Post mortem abdomen images obtained from a rat presented good image quality and no artifacts related to field non-homogeneity were observed.
Collapse
Affiliation(s)
- Maíra M. Garcia
- Faculty of Electrical Engineering and Applied Natural Sciences, Westphalian University, Neidenburger Straße 43, Campus Gelsenkirchen , Germany
- General and Theoretical Electrical Engineering (ATE), Faculty of Engineering, University of Duisburg-Essen, Bismarck Straße 81, Campus Duisburg , Germany
| | - Tiago R. Oliveira
- Department of Biomedical Engineering, Federal University of ABC, Campus Sao Bernardo do Campo , Brazil
| | - Daniel Papoti
- Department of Biomedical Engineering, Federal University of ABC, Campus Sao Bernardo do Campo , Brazil
| | - Khallil T. Chaim
- Department and Institute of Radiology, University of Sao Paulo, Campus Sao Paulo , Brazil
| | - Maria C. G. Otaduy
- Department and Institute of Radiology, University of Sao Paulo, Campus Sao Paulo , Brazil
| | - Daniel Erni
- General and Theoretical Electrical Engineering (ATE), Faculty of Engineering, University of Duisburg-Essen, and CENIDE – Center for Nanointegration Duisburg-Essen, Duisburg , Germany
| | - Waldemar Zylka
- Faculty of Electrical Engineering and Applied Natural Sciences, Westphalian University, Campus Gelsenkirchen , Germany
| |
Collapse
|
2
|
Rozenfeld JHK, Duarte EL, Oliveira TR, Lamy MT. Structural insights on biologically relevant cationic membranes by ESR spectroscopy. Biophys Rev 2017; 9:633-647. [PMID: 28836112 PMCID: PMC5662045 DOI: 10.1007/s12551-017-0304-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Accepted: 07/28/2017] [Indexed: 12/26/2022] Open
Abstract
Cationic bilayers have been used as models to study membrane fusion, templates for polymerization and deposition of materials, carriers of nucleic acids and hydrophobic drugs, microbicidal agents and vaccine adjuvants. The versatility of these membranes depends on their structure. Electron spin resonance (ESR) spectroscopy is a powerful technique that employs hydrophobic spin labels to probe membrane structure and packing. The focus of this review is the extensive structural characterization of cationic membranes prepared with dioctadecyldimethylammonium bromide or diC14-amidine to illustrate how ESR spectroscopy can provide important structural information on bilayer thermotropic behavior, gel and fluid phases, phase coexistence, presence of bilayer interdigitation, membrane fusion and interactions with other biologically relevant molecules.
Collapse
Affiliation(s)
- Julio H K Rozenfeld
- Departamento de Biofísica, Escola Paulista de Medicina, Universidade Federal de São Paulo, R. Botucatu 862, São Paulo, SP, 04023-062, Brazil
| | - Evandro L Duarte
- Instituto de Física, Universidade de São Paulo, R. do Matão 1371, São Paulo, SP, 05508-090, Brazil
| | - Tiago R Oliveira
- Centro de Engenharia, Modelagem e Ciências Sociais Aplicadas, Universidade Federal do ABC, R. Arcturus (Jd Antares), São Bernardo do Campo, SP, Brazil
| | - M Teresa Lamy
- Instituto de Física, Universidade de São Paulo, R. do Matão 1371, São Paulo, SP, 05508-090, Brazil.
| |
Collapse
|
3
|
Rodrigues DB, Maccarini PF, Salahi S, Oliveira TR, Pereira PJS, Limao-Vieira P, Snow BW, Reudink D, Stauffer PR. Design and optimization of an ultra wideband and compact microwave antenna for radiometric monitoring of brain temperature. IEEE Trans Biomed Eng 2014; 61:2154-60. [PMID: 24759979 DOI: 10.1109/tbme.2014.2317484] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We present the modeling efforts on antenna design and frequency selection to monitor brain temperature during prolonged surgery using noninvasive microwave radiometry. A tapered log-spiral antenna design is chosen for its wideband characteristics that allow higher power collection from deep brain. Parametric analysis with the software HFSS is used to optimize antenna performance for deep brain temperature sensing. Radiometric antenna efficiency (η) is evaluated in terms of the ratio of power collected from brain to total power received by the antenna. Anatomical information extracted from several adult computed tomography scans is used to establish design parameters for constructing an accurate layered 3-D tissue phantom. This head phantom includes separate brain and scalp regions, with tissue equivalent liquids circulating at independent temperatures on either side of an intact skull. The optimized frequency band is 1.1-1.6 GHz producing an average antenna efficiency of 50.3% from a two turn log-spiral antenna. The entire sensor package is contained in a lightweight and low-profile 2.8 cm diameter by 1.5 cm high assembly that can be held in place over the skin with an electromagnetic interference shielding adhesive patch. The calculated radiometric equivalent brain temperature tracks within 0.4 °C of the measured brain phantom temperature when the brain phantom is lowered 10 °C and then returned to the original temperature (37 °C) over a 4.6-h experiment. The numerical and experimental results demonstrate that the optimized 2.5-cm log-spiral antenna is well suited for the noninvasive radiometric sensing of deep brain temperature.
Collapse
|
4
|
Stauffer PR, Snow BW, Rodrigues DB, Salahi S, Oliveira TR, Reudink D, Maccarini PF. Non-invasive measurement of brain temperature with microwave radiometry: demonstration in a head phantom and clinical case. Neuroradiol J 2014; 27:3-12. [PMID: 24571829 DOI: 10.15274/nrj-2014-10001] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2013] [Accepted: 12/14/2013] [Indexed: 12/27/2022] Open
Abstract
This study characterizes the sensitivity and accuracy of a non-invasive microwave radiometric thermometer intended for monitoring body core temperature directly in brain to assist rapid recovery from hypothermia such as occurs during surgical procedures. To study this approach, a human head model was constructed with separate brain and scalp regions consisting of tissue equivalent liquids circulating at independent temperatures on either side of intact skull. This test setup provided differential surface/deep tissue temperatures for quantifying sensitivity to change in brain temperature independent of scalp and surrounding environment. A single band radiometer was calibrated and tested in a multilayer model of the human head with differential scalp and brain temperature. Following calibration of a 500MHz bandwidth microwave radiometer in the head model, feasibility of clinical monitoring was assessed in a pediatric patient during a 2-hour surgery. The results of phantom testing showed that calculated radiometric equivalent brain temperature agreed within 0.4°C of measured temperature when the brain phantom was lowered 10°C and returned to original temperature (37°C), while scalp was maintained constant over a 4.6-hour experiment. The intended clinical use of this system was demonstrated by monitoring brain temperature during surgery of a pediatric patient. Over the 2-hour surgery, the radiometrically measured brain temperature tracked within 1-2°C of rectal and nasopharynx temperatures, except during rapid cooldown and heatup periods when brain temperature deviated 2-4°C from slower responding core temperature surrogates. In summary, the radiometer demonstrated long term stability, accuracy and sensitivity sufficient for clinical monitoring of deep brain temperature during surgery.
Collapse
Affiliation(s)
- Paul R Stauffer
- Departments of Radiation Oncology and Biomedical Engineering, Duke University; Durham, NC, USA - Department of Radiation Oncology, Thomas Jefferson University; Philadelphia PA, USA -
| | - Brent W Snow
- Department of Surgery and Urology, University of Utah; Salt Lake City, UT, USA - Thermimage Inc.; Salt Lake City, UT, USA
| | - Dario B Rodrigues
- Departments of Radiation Oncology and Biomedical Engineering, Duke University; Durham, NC, USA - CEFITEC, FCT, New University of Lisbon; Caparica, Portugal
| | - Sara Salahi
- Departments of Radiation Oncology and Biomedical Engineering, Duke University; Durham, NC, USA - ANSYS, Inc.; Irvine, CA, USA
| | - Tiago R Oliveira
- Departments of Radiation Oncology and Biomedical Engineering, Duke University; Durham, NC, USA - Institute of Physics, University of São Paulo; São Paulo, Brazil
| | | | - Paolo F Maccarini
- Departments of Radiation Oncology and Biomedical Engineering, Duke University; Durham, NC, USA
| |
Collapse
|
5
|
Oliveira TR, Stauffer PR, Lee CT, Landon CD, Etienne W, Ashcraft KA, McNerny KL, Mashal A, Nouls J, Maccarini PF, Beyer WF, Inman B, Dewhirst MW. Magnetic fluid hyperthermia for bladder cancer: a preclinical dosimetry study. Int J Hyperthermia 2013; 29:835-44. [PMID: 24050253 DOI: 10.3109/02656736.2013.834384] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE This paper describes a preclinical investigation of the feasibility of thermotherapy treatment of bladder cancer with magnetic fluid hyperthermia (MFH), performed by analysing the thermal dosimetry of nanoparticle heating in a rat bladder model. MATERIALS AND METHODS The bladders of 25 female rats were instilled with magnetite-based nanoparticles, and hyperthermia was induced using a novel small animal magnetic field applicator (Actium Biosystems, Boulder, CO). We aimed to increase the bladder lumen temperature to 42 °C in <10 min and maintain that temperature for 60 min. Temperatures were measured within the bladder lumen and throughout the rat with seven fibre-optic probes (OpSens Technologies, Quebec, Canada). An MRI analysis was used to confirm the effectiveness of the catheterisation method to deliver and maintain various nanoparticle volumes within the bladder. Thermal dosimetry measurements recorded the temperature rise of rat tissues for a variety of nanoparticle exposure conditions. RESULTS Thermal dosimetry data demonstrated our ability to raise and control the temperature of rat bladder lumen ≥1 °C/min to a steady state of 42 °C with minimal heating of surrounding normal tissues. MRI scans confirmed the homogenous nanoparticle distribution throughout the bladder. CONCLUSION These data demonstrate that our MFH system with magnetite-based nanoparticles provides well-localised heating of rat bladder lumen with effective control of temperature in the bladder and minimal heating of surrounding tissues.
Collapse
Affiliation(s)
- Tiago R Oliveira
- Department of Radiation Oncology, Duke University Medical Center , Durham, North Carolina , USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Rozenfeld JHK, Duarte EL, Oliveira TR, Lonez C, Ruysschaert JM, Lamy MT. Oligonucleotide adsorption affects phase transition but not interdigitation of diC14-amidine bilayers. Langmuir 2013; 29:11102-11108. [PMID: 23926901 DOI: 10.1021/la4016004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this work, we investigate the effect of a small single-stranded oligonucleotide (ODN) on the colloid stability and structure of cationic diC14-amidine liposomes. Dynamic light scattering (DLS) shows that small, stable, anionic assemblies are formed in presence of excess ODN negative charge. This charge overcompensation condition was further characterized. A less cooperative bilayer phase transition is observed by differential scanning calorimetry (DSC). Electron spin resonance (ESR) spectra of probes at different bilayer depths show that ODN electrostatic adsorption increases the rigidity of both interdigitated gel and lamellar fluid phases. The increase in gel phase rigidity could be explained by the transformation of an adjacent to an interpenetrated interdigitation. Interdigitated fusogenic bilayers may find interesting applications in delivery of therapeutic oligonucleotides.
Collapse
|
7
|
Inman BA, Etienne W, Rubin R, Owusu RA, Oliveira TR, Rodriques DB, Maccarini PF, Stauffer PR, Mashal A, Dewhirst MW. The impact of temperature and urinary constituents on urine viscosity and its relevance to bladder hyperthermia treatment. Int J Hyperthermia 2013; 29:206-10. [PMID: 23489163 DOI: 10.3109/02656736.2013.775355] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE The aim of this study was to determine the kinematic viscosity of human urine and factors associated with its variability. This value is necessary for accurate modelling of fluid mechanics and heat transfer during hyperthermia treatments of bladder cancer. MATERIALS AND METHODS Urine samples from 64 patients undergoing routine clinical testing were subject to dipstick urinalysis and measurement of viscosity with a Cannon-Fenske viscometer. Viscosity measurements were taken at relevant temperatures for hyperthermia studies: 20 °C (room temperature), 37 °C (body temperature), and 42 °C (clinical hyperthermia temperature). Factors that might affect viscosity were assessed, including glucosuria, haematuria, urinary tract infection status, ketonuria and proteinuria status. The correlation of urine specific gravity and viscosity was measured with Spearman's rho. RESULTS Urine kinematic viscosity at 20 °C was 1.0700 cSt (standard deviation (SD) = 0.1076), at 37 °C 0.8293 cSt (SD = 0.0851), and at 42 °C 0.6928 cSt (SD = 0.0247). Proteinuria appeared to increase urine viscosity, whereas age, gender, urinary tract infection, glucosuria, ketonuria, and haematuria did not affect it. Urine specific gravity was only modestly correlated with urine viscosity at 20 °C (rho = 0.259), 37 °C (rho = 0.266), and 42 °C (rho = 0.255). CONCLUSIONS The kinematic viscosity of human urine is temperature dependent and higher than water. Urine specific gravity was not a good predictor of viscosity. Of factors that might affect urine viscosity, only proteinuria appeared to be clinically relevant. Estimates of urine viscosity provided in this manuscript may be useful for temperature modelling of bladder hyperthermia treatments with regard to correct prediction of the thermal conduction effects.
Collapse
Affiliation(s)
- Brant A Inman
- Division of Urology, Duke University Medical Center, Durham, NC 27710, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Stauffer PR, Rodriques DB, Salahi S, Topsakal E, Oliveira TR, Prakash A, D'Isidoro F, Reudink D, Snow BW, Maccarini PF. Stable Microwave Radiometry System for Long Term Monitoring of Deep Tissue Temperature. Proc SPIE Int Soc Opt Eng 2013; 8584. [PMID: 24244830 DOI: 10.1117/12.2003976] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND There are numerous clinical applications for non-invasive monitoring of deep tissue temperature. We present the design and experimental performance of a miniature radiometric thermometry system for measuring volume average temperature of tissue regions located up to 5cm deep in the body. METHODS We constructed a miniature sensor consisting of EMI-shielded log spiral microstrip antenna with high gain on-axis and integrated high-sensitivity 1.35GHz total power radiometer with 500 MHz bandwidth. We tested performance of the radiometry system in both simulated and experimental multilayer phantom models of several intended clinical measurement sites: i) brown adipose tissue (BAT) depots within 2cm of the skin surface, ii) 3-5cm deep kidney, and iii) human brain underlying intact scalp and skull. The physical models included layers of circulating tissue-mimicking liquids controlled at different temperatures to characterize our ability to quantify small changes in target temperature at depth under normothermic surface tissues. RESULTS We report SAR patterns that characterize the sense region of a 2.6cm diameter receive antenna, and radiometric power measurements as a function of deep tissue temperature that quantify radiometer sensitivity. The data demonstrate: i) our ability to accurately track temperature rise in realistic tissue targets such as urine refluxed from prewarmed bladder into kidney, and 10°C drop in brain temperature underlying normothermic scalp and skull, and ii) long term accuracy and stability of ∓0.4°C over 4.5 hours as needed for monitoring core body temperature over extended surgery or monitoring effects of brown fat metabolism over an extended sleep/wake cycle. CONCLUSIONS A non-invasive sensor consisting of 2.6cm diameter receive antenna and integral 1.35GHz total power radiometer has demonstrated sufficient sensitivity to track clinically significant changes in temperature of deep tissue targets underlying normothermic surface tissues for clinical applications like the detection of vesicoureteral reflux, and long term monitoring of brown fat metabolism or brain core temperature during extended surgery.
Collapse
Affiliation(s)
- Paul R Stauffer
- Radiation Oncology Dept., Duke University, Durham NC USA 27705
| | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Oliveira TR, Stauffer PR, Lee CT, Landon C, Etienne W, Maccarini PF, Inman B, Dewhirst MW. Preclinical Dosimetry of Magnetic Fluid Hyperthermia for Bladder Cancer. Proc SPIE Int Soc Opt Eng 2013; 8584:1656985. [PMID: 23837123 DOI: 10.1117/12.2005623] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND Despite positive efficacy, thermotherapy is not widely used in clinical oncology. Difficulties associated with field penetration and controlling power deposition patterns in heterogeneous tissue have limited its use for heating deep in the body. Heat generation using iron-oxide super-paramagnetic nanoparticles excited with magnetic fields has been demonstrated to overcome some of these limitations. The objective of this preclinical study is to investigate the feasibility of treating bladder cancer with magnetic fluid hyperthermia (MFH) by analyzing the thermal dosimetry of nanoparticle heating in a rat bladder model. METHODS The bladders of 25 female rats were injected with 0.4 ml of Actium Biosystems magnetite-based nanoparticles (Actium Biosystems, Boulder CO) via catheters inserted in the urethra. To assess the distribution of nanoparticles in the rat after injection we used the 7 T small animal MRI system (Bruker ClinScan, Bruker BioSpin MRI GmbH, Ettlingen, Germany). Heat treatments were performed with a small animal magnetic field applicator (Actium Biosystems, Boulder CO) with a goal of raising bladder temperature to 42°C in <10min and maintaining for 60min. Temperatures were measured throughout the rat with seven fiberoptic temperature probes (OpSens Technologies, Quebec Canada) to characterize our ability to localize heat within the bladder target. RESULTS The MRI study confirms the effectiveness of the catheterization procedure to homogenously distribute nanoparticles throughout the bladder. Thermal dosimetry data demonstrate our ability to controllably raise temperature of rat bladder ≥1°C/min to a steady-state of 42°C. CONCLUSION Our data demonstrate that a MFH system provides well-localized heating of rat bladder with effective control of temperature in the bladder and minimal heating of surrounding tissues.
Collapse
Affiliation(s)
- Tiago R Oliveira
- Radiation Oncology Department, Duke University, Durham, NC, 27710 ; Instituto de Física, Universidade de São Paulo, São Paulo, Brazil 05508-090
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Oliveira TR, Duarte EL, Lamy MT, Vandenbranden M, Ruysschaert JM, Lonez C. Temperature-dependence of cationic lipid bilayer intermixing: possible role of interdigitation. Langmuir 2012; 28:4640-4647. [PMID: 22332736 DOI: 10.1021/la3001569] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
In this work, we investigated the properties of a fusogenic cationic lipid, diC14-amidine, and show that this lipid possesses per se the capacity to adopt either an interdigitated structure (below and around its transition temperature) or a lamellar structure (above the transition temperature). To provide experimental evidence of this lipid bilayer organization, phospholipids spin-labeled at different positions of the hydrocarbon chain were incorporated into the membrane and their electron spin resonance (ESR) spectra were recorded at different temperatures. For comparison, similar experiments were performed with dimyristoyl phosphatidylcholine, a zwitterionic lipid (DMPC) which adopts a bilayer organization over a broad temperature range. Lipid mixing between diC14-amidine and asolectin liposomes was more efficient below (10-15 °C) than above the transition temperature (above 25 °C). This temperature-dependent "fusogenic" activity of diC14-amidine liposomes is opposite to what has been observed so far for peptides or virus-induced fusion. Altogether, our data suggest that interdigitation is a highly fusogenic state and that interdigitation-mediated fusion occurs via an unusual temperature-dependent mechanism that remains to be deciphered.
Collapse
Affiliation(s)
- Tiago R Oliveira
- Instituto de Física, Universidade de São Paulo, São Paulo, Brazil
| | | | | | | | | | | |
Collapse
|
11
|
Oliveira TR, Benatti CR, Lamy MT. Structural characterization of the interaction of the polyene antibiotic Amphotericin B with DODAB bicelles and vesicles. Biochimica et Biophysica Acta (BBA) - Biomembranes 2011; 1808:2629-37. [DOI: 10.1016/j.bbamem.2011.07.042] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2011] [Revised: 07/27/2011] [Accepted: 07/28/2011] [Indexed: 10/18/2022]
|
12
|
Silva AC, Oliveira TR, Mamani JB, Malheiros SMF, Malavolta L, Pavon LF, Sibov TT, Amaro E, Tannús A, Vidoto ELG, Martins MJ, Santos RS, Gamarra LF. Application of hyperthermia induced by superparamagnetic iron oxide nanoparticles in glioma treatment. Int J Nanomedicine 2011; 6:591-603. [PMID: 21674016 PMCID: PMC3107718 DOI: 10.2147/ijn.s14737] [Citation(s) in RCA: 97] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Indexed: 11/23/2022] Open
Abstract
Gliomas are a group of heterogeneous primary central nervous system (CNS) tumors arising from the glial cells. Malignant gliomas account for a majority of malignant primary CNS tumors and are associated with high morbidity and mortality. Glioblastoma is the most frequent and malignant glioma, and despite the recent advances in diagnosis and new treatment options, its prognosis remains dismal. New opportunities for the development of effective therapies for malignant gliomas are urgently needed. Magnetic hyperthermia (MHT), which consists of heat generation in the region of the tumor through the application of magnetic nanoparticles subjected to an alternating magnetic field (AMF), has shown positive results in both preclinical and clinical assays. The aim of this review is to assess the relevance of hyperthermia induced by magnetic nanoparticles in the treatment of gliomas and to note the possible variations of the technique and its implication on the effectiveness of the treatment. We performed an electronic search in the literature from January 1990 to October 2010, in various databases, and after application of the inclusion criteria we obtained a total of 15 articles. In vitro studies and studies using animal models showed that MHT was effective in the promotion of tumor cell death and reduction of tumor mass or increase in survival. Two clinical studies showed that MHT could be applied safely and with few side effects. Some studies suggested that mechanisms of cell death, such as apoptosis, necrosis, and antitumor immune response were triggered by MHT. Based on these data, we could conclude that MHT proved to be efficient in most of the experiments, and that the improvement of the nanocomposites as well as the AMF equipment might contribute toward establishing MHT as a promising tool in the treatment of malignant gliomas.
Collapse
Affiliation(s)
- André C Silva
- Instituto Israelita de Ensino e Pesquisa Albert Einstein, IIEPAE, São Paulo, Brazil
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Oliveira TR, Lamy MT, De Paula UM, Guimarães LL, Toledo MS, Takahashi HK, Straus AH, Lindsey CJ, Paiva TB. Structural properties of lipid reconstructs and lipid composition of normotensive and hypertensive rat vascular smooth muscle cell membranes. ACTA ACUST UNITED AC 2009; 42:844-53. [PMID: 19649392 DOI: 10.1590/s0100-879x2009005000012] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2008] [Accepted: 06/10/2009] [Indexed: 11/22/2022]
Abstract
Multiple cell membrane alterations have been reported to be the cause of various forms of hypertension. The present study focuses on the lipid portion of the membranes, characterizing the microviscosity of membranes reconstituted with lipids extracted from the aorta and mesenteric arteries of spontaneously hypertensive (SHR) and normotensive control rat strains (WKY and NWR). Membrane-incorporated phospholipid spin labels were used to monitor the bilayer structure at different depths. The packing of lipids extracted from both aorta and mesenteric arteries of normotensive and hypertensive rats was similar. Lipid extract analysis showed similar phospholipid composition for all membranes. However, cholesterol content was lower in SHR arteries than in normotensive animal arteries. These findings contrast with the fact that the SHR aorta is hyporeactive while the SHR mesenteric artery is hyperreactive to vasopressor agents when compared to the vessels of normotensive animal strains. Hence, factors other than microviscosity of bulk lipids contribute to the vascular smooth muscle reactivity and hypertension of SHR. The excess cholesterol in the arteries of normotensive animal strains apparently is not dissolved in bulk lipids and is not directly related to vascular reactivity since it is present in both the aorta and mesenteric arteries. The lower cholesterol concentrations in SHR arteries may in fact result from metabolic differences due to the hypertensive state or to genes that co-segregate with those that determine hypertension during the process of strain selection.
Collapse
Affiliation(s)
- T R Oliveira
- Departamento de Física Geral, Instituto de Física, Universidade de São Paulo, SP, Brasil
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Duarte EL, Oliveira TR, Alves DS, Micol V, Lamy MT. On the interaction of the anthraquinone barbaloin with negatively charged DMPG bilayers. Langmuir 2008; 24:4041-4049. [PMID: 18318556 DOI: 10.1021/la703896w] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Barbaloin is a bioactive glycosilated 1,8-dihydroxyanthraquinone present in several exudates from plants, such as Aloe vera, which are used for cosmetic or food purposes. It has been shown that barbaloin interacts with DMPG (dimyristoylphosphatidylglycerol) model membranes, altering the bilayer structure (Alves, D. S.; Pérez-Fons, L.; Estepa, A.; Micol, V. Biochem. Pharm. 2004, 68, 549). Considering that ESR (electron spin resonance) of spin labels is one of the best techniques to monitor structural properties at the molecular level, the alterations caused by the anthraquinone barbaloin on phospholipid bilayers will be discussed here via the ESR signal of phospholipid spin probes intercalated into the membranes. In DMPG at high ionic strength (10 mM Hepes pH 7.4 + 100 mM NaCl), a system that presents a gel-fluid transition around 23 degrees C, 20 mol % barbaloin turns the gel phase more rigid, does not alter much the fluid phase packing, but makes the lipid thermal transition less sharp. However, in a low-salt DMPG dispersion (10 mM Hepes pH 7.4 + 2 mM NaCl), which presents a rather complex gel-fluid thermal transition (Lamy-Freund, M. T.; Riske, K. A. Chem. Phys. Lipids 2003, 122, 19), barbaloin strongly affects bilayer structural properties, both in the gel and fluid phases, extending the transition region to much higher temperature values. The position of barbaloin in DMPG bilayers will be discussed on the basis of ESR results, in parallel with data from sample viscosity, DSC (differential scanning calorimetry), and SAXS (small-angle X-ray scattering).
Collapse
Affiliation(s)
- Evandro L Duarte
- Instituto de Física, Universidade de São Paulo, CEP 05315-970, São Paulo, SP, Brazil.
| | | | | | | | | |
Collapse
|
15
|
Medugno CC, de M Lessa M, Oliveira TR, Lamy MT. Double-chain cationic surfactant and n-pentanol: an L3 phase in the rich-water domain? J Phys Chem B 2007; 111:11892-4. [PMID: 17927272 DOI: 10.1021/jp074810+] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A ternary system containing water, pentanol and a quaternary cationic surfactant, dioctadecyldimethylammonium bromide (DODAB) was investigated. We present the phase diagram and ESR studies that demonstrate the existence of the well-known L3 or sponge phase in the water-rich domain of the diagram. The remarkable fact is the existence of some kind of order in such diluted conditions.
Collapse
Affiliation(s)
- Claudia C Medugno
- Embrapa Meio Ambiente, Rodovia Campinas Mogi Mirim, Tanquinho Velho, CP 69, BR-13820000, Jaguariúna, SP, Brazil
| | | | | | | |
Collapse
|