1
|
Chappuis V, Rahman L, Buser R, Janner S, Belser U, Buser D. Effectiveness of Contour Augmentation with Guided Bone Regeneration: 10-Year Results. J Dent Res 2017; 97:266-274. [DOI: 10.1177/0022034517737755] [Citation(s) in RCA: 81] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Affiliation(s)
- V. Chappuis
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - L. Rahman
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - R. Buser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - S.F.M. Janner
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - U.C. Belser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - D. Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Wittneben J, Gavric J, Belser U, Bornstein M, Joda T, Chappuis V, Sailer I, Brägger U. Esthetic and Clinical Performance of Implant-Supported All-Ceramic Crowns Made with Prefabricated or CAD/CAM Zirconia Abutments: A Randomized, Multicenter Clinical Trial. J Dent Res 2016; 96:163-170. [DOI: 10.1177/0022034516681767] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
Patients’ esthetic expectations are increasing, and the options of the prosthetic pathways are currently evolving. The objective of this randomized multicenter clinical trial was to assess and compare the esthetic outcome and clinical performance of anterior maxillary all-ceramic implant crowns (ICs) based either on prefabricated zirconia abutments veneered with pressed ceramics or on CAD/CAM zirconia abutments veneered with hand buildup technique. The null hypothesis was that there is no statistically significant difference between the 2 groups. Forty implants were inserted in sites 14 to 24 (FDI) in 40 patients in 2 centers, the Universities of Bern and Geneva, Switzerland. After final impression, 20 patients were randomized into group A, restored with a 1-piece screw-retained single crown made of a prefabricated zirconia abutment with pressed ceramic as the veneering material using the cut-back technique, or group B using an individualized CAD/CAM zirconia abutment (CARES abutment; Institut Straumann AG) with a hand buildup technique. At baseline, 6 mo, and 1 y clinical, esthetic and radiographic parameters were assessed. Group A exhibited 1 dropout patient and 1 failure, resulting in a survival rate of 94.7% after 1 y, in comparison to 100% for group B. No other complications occurred. Clinical parameters presented stable and healthy peri-implant soft tissues. Overall, no or only minimal crestal bone changes were observed with a mean DIB (distance from the implant shoulder to the first bone-to-implant contact) of −0.15 mm (group A) and 0.12 mm (group B) at 1 y. There were no significant differences at baseline, 6 mo, and 1 y for DIB values between the 2 groups. Pink esthetic score (PES) and white esthetic score (WES) values at all 3 examinations indicated stability over time for both groups and pleasing esthetic outcomes. Both implant-supported prosthetic pathways represent a valuable treatment option for the restoration of single ICs in the anterior maxilla ( ClinicalTrials.gov NCT02905838).
Collapse
Affiliation(s)
- J.G. Wittneben
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA, USA
| | - J. Gavric
- Division of Fixed Prosthodontics and Biomaterials, School of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - U.C. Belser
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - M.M. Bornstein
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - T. Joda
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Section for Digital Reconstructive Technology + Implant Dentistry [DiRecT+ID], School of Dental Medicine, University of Bern, Bern, Switzerland
| | - V. Chappuis
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - I. Sailer
- Division of Fixed Prosthodontics and Biomaterials, School of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - U. Brägger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
3
|
Abstract
Dimensional alterations of the facial soft and bone tissues following tooth extraction in the esthetic zone play an essential role to achieve successful outcomes in implant therapy. This prospective study is the first to investigate the interplay between the soft tissue dimensions and the underlying bone anatomy during an 8-wk healing period. The analysis is based on sequential 3-dimensional digital surface model superimpositions of the soft and bone tissues using digital impressions and cone beam computed tomography during an 8-wk healing period. Soft tissue thickness in thin and thick bone phenotypes at extraction was similar, averaging 0.7 mm and 0.8 mm, respectively. Interestingly, thin bone phenotypes revealed a 7-fold increase in soft tissue thickness after an 8-wk healing period, whereas in thick bone phenotypes, the soft tissue dimensions remained unchanged. The observed spontaneous soft tissue thickening in thin bone phenotypes resulted in a vertical soft tissue loss of only 1.6 mm, which concealed the underlying vertical bone resorption of 7.5 mm. Because of spontaneous soft tissue thickening, no significant differences were detected in the total tissue loss between thin and thick bone phenotypes at 2, 4, 6, and 8 wk. More than 51% of these dimensional alterations occurred within 2 wk of healing. Even though the observed spontaneous soft tissue thickening in thin bone phenotypes following tooth extraction conceals the pronounced underlying bone resorption pattern by masking the true bone deficiency, spontaneous soft tissue thickening offers advantages for subsequent bone regeneration and implant therapies in sites with high esthetic demand (Clinicaltrials.gov NCT02403700).
Collapse
Affiliation(s)
- V. Chappuis
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - O. Engel
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - K. Shahim
- Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland
| | - M. Reyes
- Institute for Surgical Technology and Biomechanics, University of Bern, Bern, Switzerland
| | - C. Katsaros
- Department of Orthodontics and Dentofacial Orthopedics, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - D. Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
4
|
Abstract
Dimensional alterations of the facial bone wall following tooth extractions in the esthetic zone have a profound effect on treatment outcomes. This prospective study in 39 patients is the first to investigate three-dimensional (3D) alterations of facial bone in the esthetic zone during the initial 8 wks following flapless tooth extraction. A novel 3D analysis was carried out, based on 2 consecutive cone beam computed tomographies (CBCTs). A risk zone for significant bone resorption was identified in central areas, whereas proximal areas yielded only minor changes. Correlation analysis identified a facial bone wall thickness of ≤ 1 mm as a critical factor associated with the extent of bone resorption. Thin-wall phenotypes displayed pronounced vertical bone resorption, with a median bone loss of 7.5 mm, as compared with thick-wall phenotypes, which decreased by only 1.1 mm. For the first time, 3D analysis has allowed for documentation of dimensional alterations of the facial bone wall in the esthetic zone of humans following extraction. It also characterized a risk zone prone to pronounced bone resorption in thin-wall phenotypes. Vertical bone loss was 3.5 times more severe than findings reported in the existing literature.
Collapse
Affiliation(s)
- V. Chappuis
- University of Berne, Freiburgstrasse 7, Berne, 3010, Switzerland
| | - O. Engel
- University of Berne, Freiburgstrasse 7, Berne, 3010, Switzerland
| | - M. Reyes
- University of Berne, Freiburgstrasse 7, Berne, 3010, Switzerland
| | - K. Shahim
- University of Berne, Freiburgstrasse 7, Berne, 3010, Switzerland
| | - L.-P. Nolte
- University of Berne, Freiburgstrasse 7, Berne, 3010, Switzerland
| | - D. Buser
- University of Berne, Freiburgstrasse 7, Berne, 3010, Switzerland
| |
Collapse
|
5
|
Buser D, Chappuis V, Kuchler U, Bornstein MM, Wittneben JG, Buser R, Cavusoglu Y, Belser UC. Long-term stability of early implant placement with contour augmentation. J Dent Res 2013; 92:176S-82S. [PMID: 24158332 DOI: 10.1177/0022034513504949] [Citation(s) in RCA: 132] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.
Collapse
Affiliation(s)
- D Buser
- Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Vandenbos F, Gal J, Dandine M, Six C, Veyres P, Chappuis V, Diez M, Mazzoni L, Daideri G, Bodokh I, Carassou-Maillan A, Chamorey E. [Assessing the wearing of jewellery by French healthcare professionals]. Med Mal Infect 2011; 41:192-6. [PMID: 21251781 DOI: 10.1016/j.medmal.2010.12.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2010] [Revised: 05/27/2010] [Accepted: 12/14/2010] [Indexed: 11/25/2022]
Abstract
OBJECTIVE A prospective observation study was undertaken in seven medical centers, in the French region Alpes-Maritime, to assess nail hygiene of healthcare professionals and how often they wear hand jewellery. METHOD Seven hundred and six healthcare workers in seven medical centers were interviewed from March to April 2008. RESULTS Among the 706 professionals, 306 (43%) were wearing one or several pieces of jewellery. The nails of 81 (11.5%) were non-standard according to guidelines. Three hundred and forty-four health care professionals (49%) were wearing one or several pieces of jewellery and/or presented with non-standard nails. In univariate analysis, the wearing of jewellery was linked to the medical centre (P<0.001), to the professional category (p<0.001), to the number of times people washed their hands or used hand gel per day (ABHR) by categories (<10 times per day or ≥10 times per day) (P<0.017). In the multivariate analysis, the risk factors linked to the wearing of jewellery were the medical centers, the professional category, and the age. CONCLUSION There are still too many healthcare professionals who do not comply to French recommendations on hand hygiene concerning the wearing of jewellery and nail hygiene standards.
Collapse
Affiliation(s)
- F Vandenbos
- Centre de réhabilitation cardiorespiratoire, centre de soins de suite et de rééducation La Maison du Mineur, 577 avenue Henri-Giraud, Vence, France.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|