1
|
Determination of Vegetal Proteins in Milk Powder by Enzyme-Linked Immunosorbent Assay: Interlaboratory Study. J AOAC Int 2019. [DOI: 10.1093/jaoac/85.6.1390] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Abstract
Eight laboratories participated in a collaborative study to evaluate an enzyme-linked immunosorbent assay (ELISA) to determine soy, pea, and wheat proteins in pasteurized or ultra-high temperature (UHT) milk powders. To perform this assay, polyclonal antibodies for soy, pea, and wheat proteins were obtained from rabbit sera. Collaborators received calibration standards composed of milk powder containing 0–8% (w/w) vegetal protein in total protein and blind test samples containing approximately 1, 2, and 5% (w/w) vegetal protein. An indirect competitive ELISA was performed with a kit prepared by a participating laboratory; the kit contained plates coated with soy, pea, or wheat proteins, the corresponding specific antisera, enzyme-labeled second antibody, and substrate solution. Test samples and calibrants were extracted with phosphate-buffered saline, pH 7.4, containing 0.05% Tween and assayed with the ELISA kits. The degree of adulteration was affected by the type of heat treatment applied to the samples. The estimated percentage of vegetal protein addition was close to the theoretical value for pasteurized samples but much lower for UHT samples. For pasteurized samples, intralaboratory relative standard deviations ranged from 5 to 22% and interlaboratory relative standard deviations ranged from 14 to 34%.
Collapse
|
2
|
Development of a One Step Strip Test for the Detection of (Dihydro)streptomycin Residues in Raw Milk. FOOD AGR IMMUNOL 2010. [DOI: 10.1080/09540100099607] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022] Open
|
3
|
Nanoscale Affinity Chip Interface for Coupling Inhibition SPR Immunosensor Screening with Nano-LC TOF MS. Anal Chem 2008; 80:1159-68. [DOI: 10.1021/ac071564p] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
4
|
Spreeta-based biosensor assays for endocrine disruptors. Biosens Bioelectron 2007; 22:1908-15. [PMID: 16971108 DOI: 10.1016/j.bios.2006.08.005] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2006] [Revised: 07/28/2006] [Accepted: 08/09/2006] [Indexed: 11/21/2022]
Abstract
The construction and performance of an automated low-cost Spreeta-based prototype biosensor system for the detection of endocrine disrupting chemicals (EDCs) is described. The system consists primarily of a Spreeta miniature liquid sensor incorporated into an aluminum flow cell holder, dedicated to support a Biacore chip frame, in combination with a simple pressurized air-driven fluid system. During the optimization, a monoclonal antibody (MAb)-based immunoassay for the estrogenic compound bisphenol A (BPA) was used as a model. After the optimization two thyroxine transport protein inhibition assays for thyroid endocrine disruptors were implemented. The average noise of the system for 1 min of baseline was 1.1 microRIU (refractive index units) and it could be operated in the range of 18-22 degrees C with a minimum baseline drift (5-10 microRIU/100 min). Optimum signal to noise ratio (S/N R) was obtained using a flow cell height of 100 microm and a flow rate of 180 microl/min. The sensitivity of the Spreeta-based biosensor inhibition assays implemented (50% inhibition concentration (IC50) of 30.2 nM for BPA using MAb12 and 12.3 and 11.6 nM for thyroxine (T4) using thyroxine-binding globulin (TBG) and recombinant transthyretin (rTTR), respectively) was comparable to the sensitivity previously obtained using a Biacore 3000 (IC50 of 39.9 nM for BPA and 8.6 and 13.7 nM, respectively, for T4). The results indicate that the alternative prototype system can be used in combination with ready-to-use biosensor chip surfaces and it is potentially a useful tool for the bioeffect-related screening of EDCs.
Collapse
|
5
|
Immunoaffinity chromatography for the sample pretreatment of Taxus plant and cell extracts prior to analysis of taxanes by high-performance liquid chromatography. J Chromatogr A 2002; 948:177-85. [PMID: 12831195 DOI: 10.1016/s0021-9673(01)01456-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The application of immunoaffinity chromatography for the purification of Taxus plant and cell extracts prior to the HPLC analysis is described. Polyclonal antibodies raised against 10-deacetylbaccatin III (10-DAB III), paclitaxel's main precursor in plant, were characterised by enzymed-linked immunosorbent assay. Immunoglobulins from selected antisera were immobilised on CNBr-activated Sepharose 4B. The immunoaffinity column was used for the purification of plant and plant cell culture extracts prior to their analysis by HPLC. Immunoaffinity chromatography enabled the selective concentration of taxoids and enhanced sample clean-up.
Collapse
|
6
|
Direct biosensor immunoassays for the detection of nonmilk proteins in milk powder. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2001; 49:5201-5206. [PMID: 11714303 DOI: 10.1021/jf010440p] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The low prices of some nonmilk proteins make them attractive as potential adulterants in dairy products. An optical biosensor (BIACORE 3000) was used to develop a direct and combined biosensor immunoassay (BIA) for the simultaneous detection of soy, pea, and soluble wheat proteins in milk powders. Affinity-purified polyclonal antibodies raised against the three protein sources were immobilized in different flow channels (Fcs) on the biosensor chip (CM5). Dissolved milk powders were injected (20 microL injections at 20 microL min(-1)) through the serially connected Fcs, and the antibody-bound plant proteins were detected directly. The total run time between samples, including a regeneration step with 5 microL of 10 mM HCl, was 5 min. The limits of detection in milk powder were below 0.1% of plant protein in the total milk protein content. The antibodies also recognized some proteins from other plant sources, which made this BIA even more suitable as a broad screening assay for nonmilk proteins.
Collapse
|
7
|
Production and characterization of polyclonal antibodies to sulfamethazine and their potential use in immunoaffinity chromatography for urine sample pre-treatment. Analyst 1999; 124:1569-75. [PMID: 10746315 DOI: 10.1039/a904732h] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An immunoaffinity chromatographic (IAC) method for isolating sulfamethazine (SMZ) from incurred urine samples was developed. This was achieved by (i) generating polyclonal antibodies that recognize equally well SMZ and its major urinary metabolites, (ii) evaluating in an ELISA procedure the influence of methanol, salt and pH on the antigen-antibody interaction in order to determine the optimum conditions for IAC and (iii) covalent coupling of the IgG fractions of anti-SMZ to CNBr activated Sepharose for the preparation of re-usable immunoaffinity columns, having a high capacity for SMZ (1900 ng SMZ mL-1 gel). For desorbing SMZ from the immunoaffinity column, different elution modes were evaluated, with 40% MeOH-0.1 mol L-1 HOAc-0.5 mol L-1 NaCl being the most efficient combination. Using the IAC column for processing SMZ spiked urine samples resulted in high recoveries, ranging from 92 to 100%. Because of the high cross-reactivity with the major metabolites of SMZ present in urine of treated animals, the antibodies show excellent properties for use in both IAC and ELISA. For the isolation and concentration of the parent drug and its major metabolites, the urine could be applied directly to the IAC column, without the time-consuming step of deconjugation. Moreover, the use of IAC prior to ELISA for the analysis of incurred urine samples showed good efficiency for the elimination of matrix interferences. Owing to the urine-tissue relationship, the urine concentrations can be used to predict the presence of the parent drug in tissues and so possible violations of the maximum residue limit (MRL) can be controlled.
Collapse
|
8
|
Abstract
In 1996, the European Union established provisional maximum residue limits (MRL) for gentamicin, neomycin, streptomycin and dihydrostreptomycin in milk and tissue (0.1-5 mg kg-1). For the detection of these four aminoglycosides, three enzyme linked immunosorbent assays (ELISA) for applications in milk and kidney were developed. The screening of defatted and diluted milk resulted in limits of determination (LDM) of < 0.01 mg l-1. Kidney samples were deproteinized with a trichloroacetic acid solution (3%) and after filtration and the addition of buffer, aliquots were used in the ELISA. The LDM of the four aminoglycosides in kidney were < 0.05 mg kg-1. The ELISA were found suitable for the semi-quantitative screening of milk and kidney for the presence of the four aminoglycosides far below the MRL levels. In randomly taken milk samples (n = 776) and in kidneys derived from healthy pigs (n = 124), the aminoglycoside residues found were far below their established MRL. In eight out of the 94 kidney samples obtained from diseased animals after emergency slaughter, aminoglycoside residues were above the MRL.
Collapse
|
9
|
Abstract
Hair has been shown to be an excellent site for the accumulation of clenbuterol residues. Compared with other matrices, hair sampling is very easy and this might result in large numbers of samples. In this study, a simple digestion-extraction procedure was combined with a sensitive clenbuterol ELISA, which resulted in an easy screening procedure suitable for the detection of at least four beta-agonists. Hair from untreated cows (n = 40) resulted in low blank levels (0.9 +/- 0.7 and 0.5 +/- 0.2 ng g-1 for black and white hair, respectively). The detection limits for clenbuterol, bromobuterol, mapenterol and mabuterol were determined as 1-1.5 ng g-1 for white and 3-4 ng g-1 for black hair. The accumulation of mabuterol and mapenterol in black and white hair from treated calves was demonstrated by GC-MS. The screening assay is not suitable for the detection of cimbuterol (owing to the low extraction efficiency) and for salbutamol and terbutaline (owing to the low cross-reactivity of the antibodies used for the ELISA and the low extraction efficiency). Black hair samples from cows treated with clenbuterol were still found to be positive (> 5 ng g-1) at 23 weeks after treatment. The fast screening procedure is a powerful means to detect and track the illegal use of clenbuterol, bromobuterol, mabuterol and mapenterol in animal production.
Collapse
|
10
|
Abstract
The one step strip test described is a competitive immunoassay in which the detector reagent consists of colloidal gold particles coated with affinity purified polyclonal anti-sulfadimidine (SDD) antibodies. The capture reagent in the assay is an SDD-ovalbumin conjugate which is immobilised on the lateral flow membrane of the test device. In the test procedure, 150 microliters (four drops) of a liquid sample (buffer, urine or milk) are brought into the sample well of the test device and allowed to migrate over the membrane. The more analyte present in the sample, the more effectively it will compete with the SDD immobilised on the membrane for binding to the limited amount of antibodies of the detector reagent. A sufficient amount of SDD in the sample will therefore prevent the binding of the detector reagent to the SDD immobilised on the membrane. Therefore, a positive sample will not show a test line in the read-out zone. With spiked buffer or calf urine this was obtained at a level of > 10 ng ml-1 of SDD and with spiked (diluted) fresh cow milk at a level > 20 ng ml-1 of SDD. At these levels, the test is applicable only as a qualitative assay. The presence or absence of a test line indicates lower or higher levels of SDD, respectively. The major advantages of the one step strip test are that results can be obtained within 10 min and that all reagents are included in the test device.
Collapse
|
11
|
Pour on application of growth promoters in veal calves: analytical and histological results. Analyst 1998; 123:2665-70. [PMID: 10435321 DOI: 10.1039/a805225e] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
To investigate the possibilities for screening and confirmation methods when the 'pour on' method of application is used for administration of growth promoters, an animal experiment was performed using a cocktail of a combination of growth promoters derived from (illegal) practice. Two cocktails were used, cocktail A consisting of stanozolol and estradiol benzoate and cocktail B consisting of stanozolol, estradiol benzoate and beclomethasone dipropionate. The intended dose per animal was 110 mg stanozolol, 25 mg estradiol and 10 mg beclomethasone. The experiment was performed on 20 male veal calves, 16 treated and 4 vehicle treated controls and 3 female veal calves, 2 treated and 1 vehicle treated control. Half of the animals were shaven prior to the application of the drugs. The cocktails were administered using two types of vehicles: vehicle A; Miglyol 840 with butylated hydroxytoluene and vehicle B; di(ethyleneglycol) monobutylether. During a 28 day treatment period, one group of animals was treated once a week, another group of animals was treated once every two weeks and slaughtered. Preliminary results showed that pour on application of anabolic steroids markedly increased growth performance of veal calves, the animals treated with cocktail A performed better than the animals treated with cocktail B. Macroscopically, the thymus was reduced in weight and size in the B animals. The bulbo-urethral glands were enlarged in all treated animals. Histologically all treated animals showed squamous metaplasia in the prostate, bulbo-urethral gland and Bartholins glands. Moreover, a changed secretion pattern was observed in both the prostate and the bulbo-urethral gland. Severe cortical atrophy was observed in the thymus and to a lesser extent the adrenals of the beclomethasone treated animals. The recently discovered 16 beta-hydroxy-metabolite of stanozolol was detected in urine, in relatively high concentrations. This is the first report of the excretion of this metabolite in urine after pour on administration showing the prospect for detection of dermal treatment. Estradiol levels were remarkably elevated (up to 200 micrograms l-1) exceeding the endogenous levels (< 1 microgram l-1).
Collapse
|
12
|
Combinations of growth promoters in veal calves: consequences for screening and confirmation methods. ZENTRALBLATT FUR VETERINARMEDIZIN. REIHE A 1998; 45:425-40. [PMID: 9793473 DOI: 10.1111/j.1439-0442.1998.tb00845.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This study investigates the influence of low dosages of beta-agonists combined with other growth promoters on screening and confirmation methods in male veal calves. Five groups of four calves were treated for 6 weeks with combinations of low dosages of beta-agonists (beta AG, clenbuterol, mabuterol and mapenterol, 0.4 microgram/kg each twice daily) in combination with 17 beta-estradiol (E2, 5 mg per animal per 14 days), methylthiouracil (MTU, 2.857 mg/kg bw twice daily) and dexamethasone (DEX, 4 mg per animal per 10 days during the last 20 days of treatment). Another group of four untreated animals served as controls. The weight and size of the thymus was reduced in the DEX group, the MTU group showed enlarged thyroids. Histologically the prostates showed vacuolar degeneration in the beta AG animals and metaplasia in the E2 group. Some vacuolization was also observed in the controls. The testis showed impaired development in all treatment groups, E2 leading to the most severe changes. DEX led to cortical atrophy of the thymus. MTU induced hyperplastic changes in the thyroid. These results indicate that comedication does not markedly affect the histological changes induced in the hormonal target tissues. For screening purposes histology of the prostate can be used as a marker for oestrogens, whereas the weight of the thymus and thyroid can be used as an indication for the use of corticosteroids and thyreostatics, respectively. Vacuolization in the prostate appeared no reliable indication for beta-agonists. Samples of urine, faeces, liver and eye (retina/choroid) were analysed for beta-agonists. E2 significantly increased the levels of all beta-agonists in the liver and faeces, whereas DEX significantly reduced these levels. These observations show that additional medication with different groups of growth promoters can markedly alter the excretion of beta-agonists and thus influence (regulatory) control.
Collapse
|
13
|
Application of an enzyme immunoassay for the determination of sulphamethazine (sulphadimidine) residues in swine urine and plasma and their use as predictors of the level in edible tissue. FOOD ADDITIVES AND CONTAMINANTS 1996; 13:811-21. [PMID: 8885321 DOI: 10.1080/02652039609374468] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The potential of an enzyme immunoassay (EIA) with high cross-reactivity towards the major metabolite (N4-acetyl-sulphamethazine) of sulphamethazine was tested for screening fluids and tissues. Healthy pigs were given 20 mg sulphamethazine per kg body weight per day in their drinking water for 2 days. Groups of four pigs were slaughtered after 3, 4 and 7 days withdrawal. The results were compared with liquid chromatographic analysis for urine, plasma, kidney, liver, gluteal muscle and diaphragm. In general, concentrations found by the EIA were higher than those found by liquid chromatography (LC) because sulphamethazine metabolites were detected by the EIA and not by LC. Using the EIA for the detection of sulphamethazine and the major metabolite in urine and plasma, predictive relationships (tissue-fluid ratios) for the concentration of the parent drug in tissue, determined by LC, were calculated. The tissue-plasma ratios for muscle, liver and kidney were 0.1, 0.2 and 0.1, respectively. The tissue-urine ratios for muscle, liver and kidney were 0.02, 0.03 and 0.03, respectively. Owing to the higher concentration of the parent drug in both fluids, the presence of the major metabolite in urine and the sensitivity of the EIA, tissue can be screened for low concentrations of sulphamethazine.
Collapse
|
14
|
Development of a tube enzyme immunoassay for "on-site' screening of urine samples in the presence of beta-agonists. Analyst 1996; 121:1111-4. [PMID: 8800016 DOI: 10.1039/an9962101111] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
An on-site screening test for the detection of beta-agonistic drugs in urine was developed. The test is based on the principle of an enzyme immunoassay in polystyrene tubes. Results can be obtained by visual interpretation or by measurement with a differential photometer. The total time required to perform the test for a set of samples (five samples+one cut-off standard) is about 20 min (visual interpretation) with an additional 2 min for an instrumental interpretation. Owing to its speed and simplicity, the test can be performed in slaughter- and farmhouses. In the tube test, a mixture of antibodies raised against clenbuterol and salbutamol is used, which makes this test sensitive towards a range of beta-agonists (multi-test). In this study, the test was applied to the screening of 269 bovine urine samples. Bovine urine samples with a level of 3 ng ml-1 of clenbuterol and higher were found positive with this on-site test. Owing to fewer matrix effects, a lower level (1 ng ml-1) could be detected in calf urine. The detection of positive samples at the place of sampling can result in more effective control of the illegal use of beta-agonists.
Collapse
|
15
|
Abstract
Fenoterol and ractopamine are phenethanolamines with beta-adrenergic agonist activity. An enzyme immunoassay (EIA) for these compounds was developed using antibodies raised in a New Zealand white rabbit against fenoterol-bovine serum albumin and fenoterol coupled to horseradish peroxidase (HRP). The calibration graphs of fenoterol and ractopamine showed linearity over the concentration ranges 0.1-5 and 0.2-25 ng ml-1, respectively. Isoxsuprine showed a cross-reactivity of 0.7% while the cross-reactivity of other beta-agonists was < 0.1%. The screening assay was used to detect fenoterol in urine samples obtained from an animal experiment in which male calves were treated with fenoterol (100 micrograms of fenoterol per kg of bodymass per meal for a period of four weeks). Using a direct method, without sample preparation, fenoterol concentrations ranged from 22 to 210 ng ml-1. The mean concentration of fenoterol after extraction in isobutanol was 3.5 times lower compared with the direct method. On applying enzymic hydrolysis in combination with isobutanol extraction, the mean concentration was eight times higher than that obtained when using extraction only. Gas chromatography-mass spectrometry (GC-MS) analysis confirmed the presence of fenoterol in most of these samples. However, probably owing to the absence of a proper GC-MS internal standard, the correlation between GC-MS and EIA concentrations was low (r = 0.7976). In general, the concentrations found by the EIA are much higher than those found by GC-MS, which might be caused by the presence of metabolites detected with the EIA. Fenoterol is excreted in urine mostly (about 85%) as glucuronidated-sulfated conjugate. The antibodies partly recognize the conjugated fenoterol, which makes it possible to use a direct screening assay. In blank calf urine the detection limits, mean background +3 times the standard deviation, are 1.3 (fenoterol) and 2.6 ng ml-1 (ractopamine). In bovine urine, however, owing to matrix effects, the detection limits are 20 times higher.
Collapse
|
16
|
Test strip enzyme immunoassays and the fast screening of nortestosterone and clenbuterol residues in urine samples at the parts per billion level. JOURNAL OF CHROMATOGRAPHY 1991; 564:413-27. [PMID: 1874846 DOI: 10.1016/0378-4347(91)80510-j] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The preliminary results of an investigation into the development of "on-site" test strip enzyme immunoassays for the screening of urine samples for the presence of growth promoters, such as 17 beta, 19-nortestosterone and clenbuterol at the parts per billion level are described. Urine samples, enzyme-labelled analyte and a nitrocellulose test strip, containing immobilized antibodies, are incubated together, after which the strip is placed in a chromogen-containing substrate solution for colour reaction. Using prefabricated strips, the tests can be performed in 45-60 min. A similar assay was worked out using a dot-blotting device, allowing the test to be performed in 20-50 min. The tests are simple and easy to perform outside the laboratory. Urine samples identified positive by gas chromatography mass spectrometry were also found to be positive with these test strips and, so far, no false-positive results have been encountered. With standard additions to blank urine samples, positive samples could be distinguished above the 5 ng ml level. However, samples from treated calves contain one or more metabolites of the parent compound, which increase the sensitivity of the assays. Although the tests described can be improved and still have to be evaluated further by analysing more urine samples, the preliminary results are very promising and give a lead to further research into the applicability of such "on-site" tests in residue analysis.
Collapse
|
17
|
Determination of clenbuterol in urine of calves by high-performance liquid chromatography with in series ultraviolet and electrochemical detection. J Pharm Biomed Anal 1991; 9:485-92. [PMID: 1747401 DOI: 10.1016/0731-7085(91)80250-d] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
A method for the determination of clenbuterol in calf urine is described. After a simple two-step sample pretreatment, involving an Extrelut-3 column and a solid-phase extraction column (C2), the separation of clenbuterol from interfering compounds present in urine samples was performed with ion-pair chromatography on a LiChrospher RP-Select-B column with a mixture of acetonitrile and sodium dodecyl sulphate/acetate buffer (pH 3.5) as mobile phase. To obtain a higher specificity, two different physico-chemical detection techniques, i.e. UV-absorption (244 nm) and electrochemical detection (+1250 mV), were applied in series. The lowest limit of determination was 0.5 ng ml-1 and the mean recovery of clenbuterol spiked at 10 ng ml-1 level was 79.9% (RSD = 6.3%; n = 9). The analysis of one urine sample, including sample preparation, took less than 2 h. Results obtained with this method correlated well with GC-MS analysis. With the described method about 400 urine samples were analysed. In a pilot experiment, in which a calf received orally 4 micrograms clenbuterol.HCl per kilogram body weight twice a day (five times the therapeutic dose for oral application) for 5 days, the highest concentration of clenbuterol found in urine was 73 ng ml-1. In a second experiment, in which two calves received the therapeutic dose of clenbuterol.HCl twice a day over a period of 2 weeks, the highest concentration of clenbuterol was 75 ng ml-1 of urine. Eight days after the final application, concentrations of clenbuterol were lower than 0.5 ng ml-1. From this excretion study for clenbuterol a half-life value of approximately 1.5 days was calculated.
Collapse
|
18
|
Rapid determination of clenbuterol residues in urine by high-performance liquid chromatography with on-line automated sample processing using immunoaffinity chromatography. J Chromatogr A 1990; 519:323-35. [PMID: 2262529 DOI: 10.1016/0021-9673(90)85161-n] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
A liquid chromatographic column-switching system for automated sample pretreatment and determination of clenbuterol in calf urine, using an immunoaffinity precolumn with Sepharose-immobilized polyclonal antibodies against clenbuterol, is described. A second precolumn packed with C18-bonded silica was used for the reconcentration of desorbed clenbuterol prior to the analytical separation. Urine, after 2-fold dilution with buffer (pH 7.4), was loaded directly onto the immuno precolumn, where clenbuterol was trapped by the immobilized antibodies. This immuno precolumn has been used for more than 200 runs with standard solutions and samples. Bound analyte was desorbed with 0.01 M acetic acid and transferred, via the second precolumn, to the analytical column. The total runtime per sample was 35 min. Using a sample load of 27 ml of dilute urine and UV detection at 244 nm, the detection limit was 0.5 ng/ml. The mean recovery of clenbuterol added to a blank urine sample at the 5 ng/ml level was 82 +/- 2% (n = 5) as determined with standard solutions loaded onto the same system. Urine samples from treated animals were analysed and the clenbuterol concentrations were comparable to those obtained by high-performance liquid chromatography using solid-phase extraction for sample clean-up.
Collapse
|
19
|
Screening and confirmation of thyreostatics in urine by gas chromatography with nitrogen-phosphorus detection and gas chromatography-mass spectrometry after sample clean-up with a mercurated affinity column. JOURNAL OF CHROMATOGRAPHY 1989; 489:127-37. [PMID: 2745644 DOI: 10.1016/s0378-4347(00)82890-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Methods are described for the screening and confirmation of residues of the thyreostatics thiouracil, methylthiouracil and propylthiouracil in urine samples of cattle at levels down to 25 micrograms/l. After a selective preconcentration of the thiol-containing thyreostatics on a mercurated affinity column, the analytes are derivatized by extractive alkylation and analysed by gas chromatography with nitrogen-phosphorus or mass spectrometric detection.
Collapse
|
20
|
Determination of beta-19-nortestosterone and its metabolite alpha-19-nortestosterone in biological samples at the sub parts per billion level by high-performance liquid chromatography with on-line immunoaffinity sample pretreatment. JOURNAL OF CHROMATOGRAPHY 1989; 489:157-71. [PMID: 2745646 DOI: 10.1016/s0378-4347(00)82892-3] [Citation(s) in RCA: 61] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
An immunoaffinity precolumn (immuno precolumn) packed with Sepharose-immobilized polyclonal antibodies against the anabolic hormone 17 beta-19-nortestosterone (beta-19-NT) was used for the selective on-line pretreatment of raw extracts of urine, bile and tissue samples by high-performance liquid chromatography. Using UV detection (247 nm), beta-19-NT and its metabolite 17 alpha-19-nortestosterone (alpha-19-NT) can be determined in biological samples with a detection limit of 0.05 microgram/kg. Owing to the high clean-up efficiency of the immuno precolumn and the large sample volumes used, confirmation by gas chromatography-mass spectrometry is possible at this level. In urine samples from a calf treated with 19-nortestosterone 17 beta-laurate, the maximum concentrations of beta-19-NT (1.3 micrograms/l) and alpha-19-NT (3.1 micrograms/l) were found seven days after intramuscular administration. In a bile sample from this calf only alpha-19-NT (55 microgram/l) was detected. In meat samples from three treated calves, the concentration of beta-19-NT varied from 0.1 to 1.6 micrograms/kg and no alpha-19-NT could be detected. In liver samples from these calves, the concentrations of beta-19-NT and alpha-19-NT were less than 0.05-0.1 and 0.5-0.9 micrograms/kg, respectively. In the corresponding kidney samples, the concentrations of beta-19-NT and alpha-19-NT were 0.4-0.5 and 0.5-1.6 micrograms/kg, respectively. The application of the same immuno precolumn to the determination of 17 beta- and 17 alpha-trenbolone, two structurally related steroids, is also demonstrated.
Collapse
|
21
|
High-performance liquid chromatography determination of the extent of proteolysis in gouda cheese. J Chromatogr A 1989. [DOI: 10.1016/s0021-9673(01)93131-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
Immunoaffinity pre-column for selective on-line sample pre-treatment in high-performance liquid chromatography determination of 19-nortestosterone. J Chromatogr A 1988; 452:419-33. [PMID: 3072346 DOI: 10.1016/s0021-9673(01)81465-5] [Citation(s) in RCA: 70] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
A liquid chromatographic column-switching system for automated sample pretreatment and determination of the anabolic hormone beta-19-nortestosterone (beta-19-NT) and its metabolite alpha-19-nortestosterone (19-norepitestosterone) in calf urine is described. The system consists of an immunoaffinity pre-column (immuno pre-column) packed with Sepharose-immobilized polyclonal antibodies against beta-19-NT, a second pre-column packed with C18 bonded silica and an analytical C18 column. Urine (25 ml) is directly loaded on the immuno pre-column, where the analytes of interest are trapped by the immobilized antibodies. Next the analytes are desorbed selectively with a solution containing an excess of the cross-reacting steroid hormone norgestrel and transferred, via the second pre-column, to the analytical column. The recovery of beta-19-NT in spiked urine samples was over 95%. The detection limit was 50 ng/l for a 25-ml urine injection. The system showed no loss of analytical performance over a 6-month period, during which about 100 samples were analysed with the same immuno pre-column. The general applicability of this sample pretreatment method is discussed.
Collapse
|
23
|
The actin content of different muscles from beef and pork. Meat Sci 1988; 22:293-302. [PMID: 22055413 DOI: 10.1016/0309-1740(88)90068-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/1988] [Revised: 03/03/1988] [Accepted: 03/16/1988] [Indexed: 11/24/2022]
Abstract
In the literature 3-methylhistidine (3-MeHis) is mentioned as a parameter for the determination of meat content. Because of the variable molar ratio of 3-MeHis in the myofibrillar protein myosin, this indicator cannot be used without some restriction. However, the content of 3-MeHis in the myofibrillar protein actin is constant. Moreover, actin is relatively heat-stable in comparison with other muscle proteins. These facts made actin an interesting parameter for determination of the meat (protein) content of heated and raw meat products. Fast protein liquid chromatography (FPLC) was used to separate from a meat extract an actin-containing fraction without myosin. The actin content of the meat was calculated from its content in the fraction. The latter was determined by means of a 3-MeHis method. Several muscles of the beef and pig carcass were examined for their actin contents. Generally, the actin values were comparable with the data reported in the literature. The influence of heat treatment was also studied on one type of beef muscle. The determined actin content was not affected up to a temperature of 85°C.
Collapse
|
24
|
Rapid determination of aflatoxin B1 in Dutch feeding stuffs by high-performance liquid chromatography and post-column derivatization. J Chromatogr A 1983; 282:457-62. [PMID: 6425347 DOI: 10.1016/s0021-9673(00)91622-4] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Concentrated feeding-stuff samples are extracted with chloroform. Clean-up of the extract is carried out by applying six samples in the middle of a thin-layer plate and developing it first with diethylether. After drying and cutting off a part of the plate, development is carried out in the opposite direction with a mixture of chloroform, acetone and water. The aflatoxin-containing part of the chromatogram is removed and extracted with a mixture of dichloromethane and acetone. In subsequent high-performance liquid chromatography (HPLC), the use of post-column derivatization with iodine in water results in a 50-fold increase in sensitivity, permitting determinations at the microgram/kg level. Recovery is better than 80%, and the detection limit is better than 1 microgram/kg. In the HPLC system described extracts from citrus pulp are eluted after aflatoxin B1.
Collapse
|
25
|
Rapid HPLC method for the determination of aflatoxin MI in milk at the ng/kg level. ACTA ACUST UNITED AC 1982. [DOI: 10.1007/bf00492066] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|