Medranda GA, Rogers T, Case BC, Zhang C, Cellamare M, Shea C, Rappaport H, Cohen JE, Shults CC, Ben-Dor I, Satler LF, Waksman R. The impact of cusp overlap on permanent pacemaker requirement following self-expanding transcatheter aortic valve replacement. Cardiovasc Revasc Med 2024; 59:9-13. [PMID: 37550124 DOI: 10.1016/j.carrev.2023.07.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 07/24/2023] [Indexed: 08/09/2023]
Abstract
BACKGROUND/PURPOSE The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.
Collapse
Affiliation(s)
- Giorgio A Medranda
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Toby Rogers
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America; Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, United States of America
| | - Brian C Case
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Cheng Zhang
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Matteo Cellamare
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Corey Shea
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Hank Rappaport
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Jeffrey E Cohen
- Department of Cardiac Surgery, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Christian C Shults
- Department of Cardiac Surgery, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Itsik Ben-Dor
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Lowell F Satler
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America
| | - Ron Waksman
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, United States of America.
| |
Collapse
|
2
|
Asmarats L, Gutiérrez-Alonso L, Nombela-Franco L, Regueiro A, Millán X, Tirado-Conte G, Cepas P, Li CHP, Fernández-Peregrina E, Jiménez-Quevedo P, Freixa X, Arzamendi D. Cusp-overlap technique during TAVI using the self-expanding Portico FlexNav system. Rev Esp Cardiol (Engl Ed) 2023; 76:767-773. [PMID: 36804557 DOI: 10.1016/j.rec.2023.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
INTRODUCTION AND OBJECTIVES The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.
Collapse
Affiliation(s)
- Lluis Asmarats
- Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Lola Gutiérrez-Alonso
- Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Luis Nombela-Franco
- Servicio de Cardiología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - Ander Regueiro
- Servicio de Cardiología, Hospital Clínic Barcelona, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Xavier Millán
- Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Gabriela Tirado-Conte
- Servicio de Cardiología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - Pedro Cepas
- Servicio de Cardiología, Hospital Clínic Barcelona, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Chi Hion Pedro Li
- Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Estefanía Fernández-Peregrina
- Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain
| | - Pilar Jiménez-Quevedo
- Servicio de Cardiología, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - Xavier Freixa
- Servicio de Cardiología, Hospital Clínic Barcelona, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Dabit Arzamendi
- Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain.
| |
Collapse
|
3
|
Gada H, Vora AN, Tang GHL, Mumtaz M, Forrest JK, Laham RJ, Yakubov SJ, Deeb GM, Rammohan C, Huang J, Reardon MJ. Site-Level Variation and Predictors of Permanent Pacemaker Implantation Following TAVR in the Evolut Low-Risk Trial. Cardiovasc Revasc Med 2023; 47:48-54. [PMID: 36266154 DOI: 10.1016/j.carrev.2022.10.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 10/10/2022] [Accepted: 10/11/2022] [Indexed: 01/28/2023]
Abstract
We evaluated predictors of permanent pacemaker implantation (PPI) following self-expanding transcatheter aortic valve replacement (TAVR), examined site-to-site variability of PPI rates, and explored the relationship of implantation methods on the need for PPI. Despite the benefits of TAVR compared to surgical aortic valve replacement, increased PPI remains a limitation. A total of 699 patients without baseline PPI were included in the study. Clinical, echocardiographic, and procedural characteristics were compared in patient with and without new PPI. Clinical outcomes were assessed at 30 days and 1 year. Funnel plots were constructed to display site-to- site variability and identify outliers in PPI. Clinical outcomes were similar in patients with and without PPI. Predictors of a new PPI within 7 days included a baseline right bundle branch block (p < 0.001) and not using general anesthesia (p = 0.003). There was substantial site to site variability in the rate of PPI. Patients at sites with a lower PPI rate had shallower implantation depth at the non-coronary (p < 0.001) and the left coronary sinus (p < 0.001), and fewer patients with an implantation depth > 5 mm below the annulus (p = 0.004). In low-risk patients undergoing TAVR with Evolut valves, baseline conduction disorders and implant depth were important predictors of PPI. Implantation method may have contributed to this variability in PPI rates across clinical sites.
Collapse
Affiliation(s)
- Hemal Gada
- Department of Interventional Cardiology, University of Pittsburgh Medical Center Pinnacle, Wormleysburg, PA, United States of America.
| | - Amit N Vora
- Department of Interventional Cardiology, University of Pittsburgh Medical Center Pinnacle, Wormleysburg, PA, United States of America
| | - Gilbert H L Tang
- Department of Cardiovascular Surgery, Mount Sinai Health System, NY, New York, United States of America
| | - Mubashir Mumtaz
- Department of Interventional Cardiology, University of Pittsburgh Medical Center Pinnacle, Wormleysburg, PA, United States of America
| | - John K Forrest
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, United States of America
| | - Roger J Laham
- Department of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, United States of America
| | - Steven J Yakubov
- Department of Interventional Cardiology, Riverside Methodist-Ohio Health, Columbus, OH, United States of America
| | - G Michael Deeb
- Department of Cardiac Surgery, University of Michigan Hospitals, Ann Arbor, MI, United States of America
| | - Chad Rammohan
- El Camino Hospital, Department of Interventional Cardiology, Mountain View, CA, United States of America
| | - Jian Huang
- Department of Statistics, Medtronic, Minneapolis, MN, United States of America
| | - Michael J Reardon
- Department of Cardiothoracic Surgery, Houston Methodist DeBakey Heart and Vascular Institute, Houston, TX, United States of America
| |
Collapse
|