1
|
Dong X, Zhang X, Du Y, Liu J, Zeng Q, Cao W, Wei Q, Ju H. Zirconium dioxide as electrochemiluminescence emitter for D-dimer determination based on dual-quenching sensing strategy. Biosens Bioelectron 2023; 236:115437. [PMID: 37263052 DOI: 10.1016/j.bios.2023.115437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 05/04/2023] [Accepted: 05/26/2023] [Indexed: 06/03/2023]
Abstract
The ECL emission of simple and stable zirconium dioxide nanomaterials has always been a blank slate in the ECL sensors field. In this work, zirconium dioxide (ZrO2)-titanium dioxide (TiO2)-gold nanoparticle (AuNPs) composite (ZT-Au), a novel self-enhanced ECL emitter, was introduced the system of dual-quenching ECL immunosensor. The anodic luminescence of ZrO2 in the system of tripropylamine (TPrA) as a co-reagent was first reported and explored. Meanwhile, TiO2 was designed into the ECL scheme as a co-reaction accelerator to form the ZrO2/TPrA/TiO2 ternary system, which can efficiently amplify the ECL signal of the emitter. In addition, cuprous oxide-triaminophenol (Cu2O-APF) as the quencher was devoted to the dual-quenching sensing strategy. The dual-quenching mechanism that effectively boosted the immunosensor sensitivity was adequately investigated and conjectured in this paper. The sensing model based on the luminophor ZT-Au and the quencher Cu2O-APF was utilized for the detection of D-dimer, a reliable marker for the diagnosis and evaluation of thrombotic diseases. The short peptide ligands NARKFYKGC (NFC) with efficient biological affinity were used to site-directionally capture antibodies for adequately protecting the activity of antigen binding sites during the construction of the immunosensor. The implemented immunosensor was equipped with a broad linear range of 0.01-500 ng/mL and a low detection limit of 3.6 pg/mL. The original methodology opens up the field of vision for the detection of additional biomarkers.
Collapse
Affiliation(s)
- Xue Dong
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Xiaoyue Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Yu Du
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Jiajun Liu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qingze Zeng
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Wei Cao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
| | - Huangxian Ju
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, PR China
| |
Collapse
|
2
|
Hu L, Shi T, Chen J, Cui Q, Yu H, Wu D, Ma H, Wei Q, Ju H. Dual-quenching electrochemiluminescence resonance energy transfer system from CoPd nanoparticles enhanced porous g-C 3N 4 to FeMOFs-sCuO for neuron-specific enolase immunosensing. Biosens Bioelectron 2023; 226:115132. [PMID: 36791617 DOI: 10.1016/j.bios.2023.115132] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Revised: 02/02/2023] [Accepted: 02/05/2023] [Indexed: 02/09/2023]
Abstract
For the diagnosis and therapy of small cell lung cancer (SCLC), the accurate and sensitive determination of neuron-specific enolase (NSE) content is crucial. This work outlines a dual-quenching electrochemiluminescence resonance energy transfer (ECL-RET) immunosensor based on the double quenching effects of iron base metal organic frameworks (FeMOFs) loaded with small sized CuO nanoparticles (FeMOFs-sCuO) towards CoPd nanoparticles (CoPdNPs) enhanced porous g-C3N4 (P-C3N4-CoPdNPs). To be specific, we prepared a porous g-C3N4 (P-C3N4) which has a rich porous structure, and significantly increased the specific surface area and the number of reaction sites of P-C3N4. Meanwhile, the CoPdNPs were loaded onto P-C3N4 to improve the ECL luminescence property of P-C3N4/K2S2O8 system through acting as a coreaction accelerator. In addition, the ultraviolet-visible (UV-vis) absorption spectra of FeMOFs and small sized CuO nanoparticles (sCuO) showed considerable overlap with the ECL emission spectra of P-C3N4 appropriately. Therefore, FeMOFs with high specific surface area were prepared and well combined with sCuO to effectively dual-quenching the ECL emission of P-C3N4 based on resonance energy transfer. Hence, a new type ECL-RET couple made up of P-C3N4-CoPdNPs (donor) and FeMOFs-sCuO (acceptor) were developed for the first time. A certain amount of P-C3N4-CoPdNPs, Ab1, BSA, NSE were modified layer by layer onto the electrode surface. Then FeMOFs-sCuO-Ab2 bioconjugates was incubated through the immune recognition binding. As a result, a sandwich-type ECL biosensor was manufactured successfully for NSE immunoassay. Under optimal experimental conditions, the limit of detection (LOD) and the limit of quantitation (LOQ) of the prepared ECL sensor for NSE analysis was 20.4 fg mL-1 and 7.99 fg mL-1, respectively, with the relative standard deviation (RSD) of 1.68%. The linear detection range was 0.0000500-100 ng mL-1. The studied immunosensor had satisfactory sensitivity, specificity and reproducibility, manifesting the suggested sensing strategy might offer a good technical means and theoretical basis for the sensitivity analysis of NSE and has a potential application in clinical diagnosis analysis.
Collapse
Affiliation(s)
- Lihua Hu
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
| | - Tengfei Shi
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Jiye Chen
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qianqian Cui
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Hao Yu
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Dan Wu
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Hongmin Ma
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qin Wei
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Huangxian Ju
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, PR China
| |
Collapse
|