Okumura Y, Inomata T, Fujimoto K, Fujio K, Zhu J, Yanagawa A, Shokirova H, Saita Y, Kobayashi Y, Nagao M, Nishio H, Sung J, Midorikawa-Inomata A, Eguchi A, Nagino K, Akasaki Y, Hirosawa K, Huang T, Kuwahara M, Murakami A. Biological effects of stored platelet-rich plasma eye-drops in corneal wound healing. Br J Ophthalmol 2023; 108:37-44. [PMID: 36162968 DOI: 10.1136/bjo-2022-322068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Accepted: 09/08/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND/AIMS This study aimed to assess the efficacy and sterility of stored platelet-rich plasma (PRP) eye-drops for corneal epithelial wound healing compared with those of autologous serum (AS) eye-drops. METHODS At our single institution, PRP and AS eye-drops were prepared using peripheral blood obtained from six healthy volunteers and stored at 4°C. Platelet and leucocyte counts and transforming growth factor (TGF)-β1, epidermal growth factor (EGF), and fibronectin levels were assessed during storage for up to 4 weeks. Sterility was assessed by culturing 4-week poststorage samples. PRP, AS, and phosphate-buffered saline (PBS) eye-drop efficacies were compared using corneal epithelial wound healing assays in vitro and in vivo and monitoring wound areas under a microscope every 3 hours. RESULTS Higher platelet and lower leucocyte counts were seen in PRP than in whole blood on the day of preparation. After storage, TGF-β1, EGF, and fibronectin levels were significantly higher in PRP than in AS eye-drops. In vitro and in vivo, PRP eye-drops used on the day of preparation significantly promoted corneal epithelial wound healing compared with PBS. Moreover, PRP eye-drops stored for 4 weeks significantly promoted corneal wound healing compared with PBS and AS eye-drops. CONCLUSION PRP eye-drops stored at 4°C for 4 weeks promoted corneal epithelial wound healing with higher levels of growth factors than those observed in AS eye-drops, while maintaining sterility, suggesting that this preparation satisfies the unmet medical needs in the treatment of refractory keratoconjunctival epithelial disorders.
Collapse
Affiliation(s)
- Yuichi Okumura
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Takenori Inomata
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- AI Incubation Farm, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Keiichi Fujimoto
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Kenta Fujio
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Jun Zhu
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Ai Yanagawa
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Hurramhon Shokirova
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Yoshitomo Saita
- Department of Sports and Regenerative Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Japan
| | - Yohei Kobayashi
- Department of Sports and Regenerative Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Japan
| | - Masahi Nagao
- Department of Sports and Regenerative Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Japan
- Department of Medical Technology Innovation Center, Juntendo University, Bunkyo-ku, Japan
| | - Hirofumi Nishio
- Department of Sports and Regenerative Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Japan
| | - Jaemyoung Sung
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- University of South Florida College of Medicine, Tampa, Florida, USA
| | - Akie Midorikawa-Inomata
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Atsuko Eguchi
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Ken Nagino
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Hospital Administration, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Yasutsugu Akasaki
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Kunihiko Hirosawa
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Tianxiang Huang
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Mizu Kuwahara
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| | - Akira Murakami
- Department of Ophthalmology, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
- Department of Digital Medicine, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
2
|
Rabensteiner DF, Rabensteiner J, Faschinger C. The influence of electromagnetic radiation on the measurement behaviour of the triggerfish® contact lens sensor. BMC Ophthalmol 2018; 18:338. [PMID: 30587178 PMCID: PMC6307119 DOI: 10.1186/s12886-018-1013-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 12/18/2018] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND To assess a possible signal drift, noise and influences of electromagnetic radiation on the measurement behaviour of the Triggerfish® contact lens sensor, which might be mistaken as IOP fluctuations. METHODS Contact lens sensors (Triggerfish®, SENSIMED AG, Lausanne, Switzerland) were fixed in a water bath. To reduce any external electromagnetic impulses, all plugs were removed from the sockets, no lights were switched on and no electronic devices, except a temperature logger were left in the test room. For 24 h signal drift, noise and the influences of a cordless telephone (Ascom d43 DECT Handset, EU DECT 1880-1900 MHz, Ascom Wireless, Baar, Switzerland), a smartphone (Sony Xperia Go ST27i, Sony Corporation, Tokyo, Japan) and a computer (Hewlett-Packard ProBook 650 15,6″ - D9S33AV, Hewlett-Packard Inc., Palo Alto, USA) on the measuring profile were analysed. RESULTS Twenty-four-hour measurements without provoked external electromagnetic impulses yielded a profile without any signal drift and 8.2 mV eq noise. During the activation of the cordless telephone a maximum measurement variation of 3.2 mV eq. (4.1-7.3), smartphone 1.8 mV eq. (4.7-6.5) and computer 1.4 mV eq. (6.3-7.7) were observed. CONCLUSIONS During 24-h measurements there was no signal drift and a very low noise. Patients concerned about electronic devices possibly interfering with the measurements of the contact lens sensor, can be informed, that the use of their cordless telephone, smartphone or computer does not cause any problems. The amount of the signal noise might help to define actual IOP fluctuations. Temperature fluctuations might influence the measuring profile.
Collapse
Affiliation(s)
| | - Jasmin Rabensteiner
- Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Auenbruggerplatz 15, 8036, Graz, Austria
| | - Christoph Faschinger
- Department of Ophthalmology, Medical University of Graz Auenbruggerplatz 4, 8036, Graz, Austria
| |