1
|
Wakamatsu Y, Nagashima K, Watanabe I, Watanabe R, Arai M, Otsuka N, Yagyu S, Kurokawa S, Ohkubo K, Nakai T, Okumura Y. The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation. J Interv Card Electrophysiol 2019; 55:277-285. [PMID: 30607666 DOI: 10.1007/s10840-018-0501-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2018] [Accepted: 12/17/2018] [Indexed: 10/27/2022]
Abstract
BACKGROUND Although pulmonary vein isolation (PVI) guided by the ablation index (AI) has been well-developed, acute PV reconnections (PVRs) still occur. This study aimed to compare the prognostic performance of the modified AI and its optimal cut-off value for the prediction of acute PVRs to ensure durable PVI. METHODS Three-dimensional left atrium (LA) voltage maps created before an extensive encircling PVI in 64 patients with atrial fibrillation (AF) (45 men, 62 ± 10 years) were examined for an association between electrogram voltage amplitude recorded from the PV-LA junction and acute post-PVI PVRs (spontaneous PVRs and/or ATP-provoked dormant PV conduction). RESULTS Acute PVRs were observed in 22 patients (34%) and 33 (3%) of the 1012 PV segments. Acute PVRs were significantly associated with segments with higher bipolar voltage zones (3.23 ± 1.17 vs. 1.97 ± 1.20 mV, P < 0.0001), lower mean AI values (449 [428-450] vs. 460 [437-486], P = 0.05), and radiofrequency lesion gaps ≥ 6 mm (48 vs. 32%, P = 0.04), but not with contact force, force-time integral, or power. We created the modified AI calculated as AI/LA bipolar voltage, and found it to be significantly lower in areas with acute PVRs than in those without (152 [109-185] vs. 256 [176-413] AU/mV, P < 0.0001). Univariate analysis showed the prognostic performance of the modified AI, with an area under the curve of 0.801 (0.775-0.825), to be the highest of all the significant parameters. CONCLUSIONS Low values of the novel modified AI on the PV-encircling ablation line were strongly associated with acute PVRs.
Collapse
Affiliation(s)
- Yuji Wakamatsu
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Koichi Nagashima
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan.
| | - Ichiro Watanabe
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Ryuta Watanabe
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Masaru Arai
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Naoto Otsuka
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Seina Yagyu
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Sayaka Kurokawa
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Kimie Ohkubo
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Toshiko Nakai
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| | - Yasuo Okumura
- Division of Cardiology, Department of Medicine, Nihon University School of Medicine, 30-1 Ohyaguchi-Kamicho, Itabashi-ku, Tokyo, 173-8610, Japan
| |
Collapse
|