[Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 08/21/2017] [Accepted: 08/21/2017] [Indexed: 11/15/2022]
Abstract
SUBJECT
The main objective of our study is to evaluate the contribution of automated conjunctival recognition in the alignment of toric implants by comparing the automatic alignment optimized with Callisto™ to the manual marking of the horizontal axis.
MATERIALS AND METHODS
We performed a prospective, descriptive, and monocentric study on patients undergoing cataract surgery with toric implantation (Asphina 709 Zeiss), operated by a surgeon with good experience in toricity, between September 2016 and March 2017. We analyzed the agreement between the manual marking of the 0°-180° axis versus the one automatically generated by the Callisto™, as well as the alignment of the IOL and the refractive results at 1 month.
RESULTS
We included 50 eyes of 26 patients. The corrected mean astigmatism was 1.9 D. The mean difference between the 2 axes was 4.7° [0°-12.3°]. Only 50 % of the preoperative manual markings were consistent with the automatic measurement (<5°). At one month, the average rotation recorded was 4.3° [0°-29°]. The alignment was identical for 70 % (n=35) of the IOL (≤5°). As for residual subjective astigmatism, it was on average 0.58 D. The mean visual acuity without correction was 8/10 and 55 % had 10/10 without correction.
DISCUSSION
The refractive performance depends on the preoperative measurement, the correct alignment of the IOL and its stability in the bag. Our study shows the value of automatic conjunctival recognition in the determination of the axis of peroperative alignment, even in an experienced operator. This precision is essential for a good refractive result, especially since the residual astigmatism in case of misalignment will increase with the power of the implant.
CONCLUSION
Our study shows excellent refractive results, whatever the initial astigmatism, using the automatic alignment. The precision of the toric implantation opens the way to the toric multifocal implantation under the best conditions.