1
|
Hu YJ, Chines A, Shi Y, Seeman E, Guo XE. The effect of denosumab and alendronate on trabecular plate and rod microstructure at the distal tibia and radius: A post-hoc HR-pQCT study. Bone 2022; 154:116187. [PMID: 34530172 DOI: 10.1016/j.bone.2021.116187] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 09/02/2021] [Accepted: 09/09/2021] [Indexed: 01/23/2023]
Abstract
BACKGROUND Age-related trabecular microstructural deterioration and conversion from plate-like trabeculae to rod-like trabeculae occur because of unbalanced rapid remodeling. As denosumab achieves greater remodeling suppression and lower cortical porosity than alendronate, we hypothesized that denosumab might also preserve trabecular plate microstructure, bone stiffness and strength more effectively than alendronate. METHODS In this post hoc analysis of a phase 2 study, postmenopausal women randomized to placebo (P, n = 74), denosumab (D, n = 72), or alendronate (A, n = 68). HR-pQCT scans of the distal radius and tibia were performed at baseline and Month-12 (M12). Trabecular compartment was subjected to Individual Trabecula Segmentation while finite element analysis was performed to estimate stiffness and strength. Percent change from baseline at M12 of each parameter was compared between patient groups. RESULTS At the distal tibia, in the placebo group, plate surface area (pTb.S, -1.3%) decreased while rod bone volume fraction (rBV/TV, +4.5%) and number (rTb.N, +2.1%) increased. These changes were prevented by denosumab but persisted despite alendronate therapy (pTb.S: -1.7%; rBV/TV: +6.9%; rTb.N: +3.0%). Both treatments improved whole bone stiffness (D: +3.1%; A: +1.8%) and failure load (D: +3.0%; A: +2.2%); improvements using denosumab was significant compared to placebo (stiffness: p = 0.004; failure load: p = 0.003). At the distal radius, denosumab increased total trabecular bone volume fraction (BV/TV, +3.4%) and whole bone failure load (+4.0%), significantly different from placebo (BV/TV: p = 0.044; failure load: p = 0.046). Significantly different effects of either drug on plate and rod microstructure were not detected. CONCLUSIONS Denosumab preserved trabecular plate microstructure. Alendronate did not. However, estimated strength did not differ between denosumab and alendronate treated groups.
Collapse
Affiliation(s)
- Yizhong Jenny Hu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | | | | | - Ego Seeman
- Departments of Endocrinology and Medicine, Austin Health, University of Melbourne, Melbourne, Australia; Mary MacKillop Institute of Healthy Aging, Australian Catholic University, Melbourne, Australia
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
2
|
Chu L, He Z, Qu X, Liu X, Zhang W, Zhang S, Han X, Yan M, Xu Q, Zhang S, Shang X, Yu Z. Different subchondral trabecular bone microstructure and biomechanical properties between developmental dysplasia of the hip and primary osteoarthritis. J Orthop Translat 2019; 22:50-57. [PMID: 32440499 PMCID: PMC7231963 DOI: 10.1016/j.jot.2019.09.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 08/29/2019] [Accepted: 09/03/2019] [Indexed: 01/21/2023] Open
Abstract
Objective Developmental dysplasia of the hip (DDH) is recognized as a frequent cause of secondary osteoarthritis (OA). The purpose in this study was to compare structural and biomechanical properties of subchondral trabecular bone and its relationship with cartilage damage between patients with DDH and patients with primary hip OA. Methods Forty-three femoral head specimens obtained from patients who underwent total hip arthroplasty [DDH, n = 17; primary OA, n = 16; and normal control (NC), n = 10] were scanned by microcomputed tomography and analyzed by individual trabecula segmentation to obtain the microstructural types of subchondral trabecular bone. The biomechanical properties were analyzed by micro-finite element analysis, and cartilage damage was evaluated by histology. The linear regression analysis was used to indicate the association between microstructures, biomechanical property, and articular cartilage. Results The DDH group showed the lowest total bone volume fractions (BV/TV) and plate BV/TV in the three groups (p < 0.05). There were also different discrepancies between the three groups in plate/rod trabecular number, plate/rod trabecular thickness, trabecular plate surface area/trabecular rod length, and junction density with different modes (plate-plate, rod-rod, and plate-rod junction density). The micro-finite element analysis, histology, and linear regression revealed that the subchondral trabecular bone in the DDH group had inferior biomechanical properties and cartilage damage of patients with DDH was more serious with different subchondral trabecular bone microstructures. Conclusion Our findings detected deteriorating subchondral trabecular bone microstructures in patients with DDH. The mass and type of subchondral trabecular bone play a key role in mechanical properties in DDH, which might be related to cartilage damage. The translational potential of this article Our findings suggested that changes of subchondral trabecular bone play a critical role in DDH progression and that the improvement on subchondral trabecular bone may be a sensitive and promising way in treatment of DDH.
Collapse
Affiliation(s)
- Linyang Chu
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Zihao He
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Xinhua Qu
- Department of Bone and Joint Surgery, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200011, PR China
| | - Xuqiang Liu
- Department of Orthopedics, The First Affiliated Hospital of Nanchang University, The Artificial Joint Engineering and Technology Research Center of Jiangxi Province, Nanchang, PR China
| | - Weituo Zhang
- Clinical Research Center, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, PR China
| | - Shuo Zhang
- Clinical Research Center, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, PR China
| | - Xuequan Han
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Mengning Yan
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Qi Xu
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Shuhong Zhang
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| | - Xifu Shang
- Department of Orthopedics, The Affiliated Provincial Hospital of China Science and Technology University, Hefei, 230001, Anhui Province, PR China
| | - Zhifeng Yu
- Shanghai Key Laboratory of Orthopedic Implants, Department of Orthopedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, PR China
| |
Collapse
|
3
|
Kepley AL, Nishiyama KK, Zhou B, Wang J, Zhang C, McMahon DJ, Foley KF, Walker MD, Guo XE, Shane E, Nickolas TL. Differences in bone quality and strength between Asian and Caucasian young men. Osteoporos Int 2017; 28:549-558. [PMID: 27638138 DOI: 10.1007/s00198-016-3762-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 08/31/2016] [Indexed: 10/21/2022]
Abstract
UNLABELLED This is a cross-sectional study to assess differences in bone quality in young Asian and Caucasian (n = 30/group) men between 25 and 35 years. We found that Asians had smaller bones, thicker and denser cortices, and more plate-like trabeculae, but stiffness did not differ between groups. INTRODUCTION We conducted a cross-sectional study to assess differences in bone quality in young Asian and Caucasian (n = 30/group) men between 25 and 35 years. METHODS We measured bone mineral density (BMD) at the spine, total hip (TH), femoral neck (FN), and forearm by dual energy X-ray absorptiometry (DXA), and bone geometry, density, microarchitecture, and mechanical competence at the radius and tibia by high-resolution peripheral quantitative computed tomography (HR-pQCT) with application of individual trabecula segmentation (ITS) and trabecular and whole bone finite element analysis (FEA). We measured load-to-strength ratio to account for differences in bone size and height, respectively. We used Wilcoxon rank sum and generalized linear models adjusted for height, weight, and their interaction for comparisons. RESULTS Asians were 3.9 % shorter and weighed 6.5 % less than Caucasians. In adjusted models: by DXA, there were no significant race-based differences in areal BMD; by HR-pQCT, at the radius, Asians had smaller total and trabecular area (p = 0.003 for both), and denser (p = 0.01) and thicker (p = 0.04) cortices at the radius; by ITS, at the radius Asians, had more plate-like than rod-like trabeculae (PR ratio p = 0.01), greater plate trabecular surface (p = 0.009) and longer rod length (p = 0.002). There were no significant race-based differences in FEA or the load-to-strength ratio. CONCLUSIONS Asians had smaller bones, thicker and denser cortices, and more plate-like trabeculae, but biomechanical estimates of bone strength did not differ between groups. Studies are needed to determine whether these differences persist later in life.
Collapse
Affiliation(s)
- A L Kepley
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - K K Nishiyama
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - B Zhou
- Biomedical Engineering, Department of Medicine, Columbia University, New York, NY, USA
| | - J Wang
- Biomedical Engineering, Department of Medicine, Columbia University, New York, NY, USA
| | - C Zhang
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - D J McMahon
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - K F Foley
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - M D Walker
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - X Edward Guo
- Biomedical Engineering, Department of Medicine, Columbia University, New York, NY, USA
| | - E Shane
- Department of Medicine, Endocrinology, Columbia Univeristy Medical Center, New York, NY, USA
| | - T L Nickolas
- Department of Medicine, Nephrology, Columbia University Medical Center, 622 West 168th Street, PH4-124, New York, NY, 10032, USA.
| |
Collapse
|
4
|
Putman MS, Greenblatt LB, Sicilian L, Uluer A, Lapey A, Sawicki G, Gordon CM, Bouxsein ML, Finkelstein JS. Young adults with cystic fibrosis have altered trabecular microstructure by ITS-based morphological analysis. Osteoporos Int 2016; 27:2497-505. [PMID: 26952010 PMCID: PMC4947435 DOI: 10.1007/s00198-016-3557-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 03/01/2016] [Indexed: 01/22/2023]
Abstract
UNLABELLED Young adults with cystic fibrosis have compromised plate-like trabecular microstructure, altered axial alignment of trabeculae, and reduced connectivity between trabeculae that may contribute to the reduced bone strength and increased fracture risk observed in this patient population. INTRODUCTION The risk of fracture is increased in patients with cystic fibrosis (CF). Individual trabecular segmentation (ITS)-based morphological analysis of high-resolution peripheral quantitative computed tomography (HR-pQCT) images segments trabecular bone into individual plates and rods of different alignment and connectivity, which are important determinants of trabecular bone strength. We sought to determine whether alterations in ITS variables are present in patients with CF and may help explain their increased fracture risk. METHODS Thirty patients with CF ages 18-40 years underwent DXA scans of the hip and spine and HR-pQCT scans of the radius and tibia with further assessment of trabecular microstructure by ITS. These CF patients were compared with 60 healthy controls matched for age (±2 years), race, and gender. RESULTS Plate volume fraction, thickness, and density as well as plate-plate and plate-rod connectivity were reduced, and axial alignment of trabeculae was lower in subjects with CF at both the radius and the tibia (p < 0.05 for all). At the radius, adjustment for BMI eliminated most of these differences. At the tibia, however, reductions in plate volume fraction and number, axially aligned trabeculae, and plate-plate connectivity remained significant after adjustment for BMI alone and for BMI and aBMD (p < 0.05 for all). CONCLUSIONS Young adults with CF have compromised plate-like and axially aligned trabecular morphology and reduced connectivity between trabeculae. ITS analysis provides unique information about bone integrity, and these trabecular deficits may help explain the increased fracture risk in adults with CF not accounted for by BMD and/or traditional bone microarchitecture measurements.
Collapse
Affiliation(s)
- M S Putman
- Endocrine Unit, Department of Medicine, Massachusetts General Hospital, 50 Blossom Street, THR-1051, Boston, MA, 02114, USA.
- Division of Endocrinology, Boston Children's Hospital, Boston, MA, USA.
| | - L B Greenblatt
- Endocrine Unit, Department of Medicine, Massachusetts General Hospital, 50 Blossom Street, THR-1051, Boston, MA, 02114, USA
| | - L Sicilian
- Pulmonary Division, Department of Medicine, Massachusetts General Hospital, Boston, MA, USA
| | - A Uluer
- Division of Respiratory Diseases, Boston Children's Hospital, Boston, MA, USA
| | - A Lapey
- Pulmonary Division, Department of Pediatrics, Massachusetts General Hospital, Boston, MA, USA
| | - G Sawicki
- Division of Respiratory Diseases, Boston Children's Hospital, Boston, MA, USA
| | - C M Gordon
- Division of Adolescent and Transition Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - M L Bouxsein
- Endocrine Unit, Department of Medicine, Massachusetts General Hospital, 50 Blossom Street, THR-1051, Boston, MA, 02114, USA
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center, Boston, MA, USA
- Department of Orthopedic Surgery, Harvard Medical School, Boston, MA, USA
| | - J S Finkelstein
- Endocrine Unit, Department of Medicine, Massachusetts General Hospital, 50 Blossom Street, THR-1051, Boston, MA, 02114, USA
| |
Collapse
|
5
|
Wang J, Stein EM, Zhou B, Nishiyama KK, Yu YE, Shane E, Guo XE. Deterioration of trabecular plate-rod and cortical microarchitecture and reduced bone stiffness at distal radius and tibia in postmenopausal women with vertebral fractures. Bone 2016; 88:39-46. [PMID: 27083398 PMCID: PMC4899124 DOI: 10.1016/j.bone.2016.04.003] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Revised: 03/07/2016] [Accepted: 04/04/2016] [Indexed: 10/21/2022]
Abstract
Postmenopausal women with vertebral fractures have abnormal bone microarchitecture at the distal radius and tibia by HR-pQCT, independent of areal BMD. However, whether trabecular plate and rod microarchitecture is altered in women with vertebral fractures is unknown. This study aims to characterize the abnormalities of trabecular plate and rod microarchitecture, cortex, and bone stiffness in postmenopausal women with vertebral fractures. HR-pQCT images of distal radius and tibia were acquired from 45 women with vertebral fractures and 45 control subjects without fractures. Trabecular and cortical compartments were separated by an automatic segmentation algorithm and subjected to individual trabecula segmentation (ITS) analysis for measuring trabecular plate and rod morphology and cortical bone evaluation for measuring cortical thickness and porosity, respectively. Whole bone and trabecular bone stiffness were estimated by finite element analysis. Fracture and control subjects did not differ according to age, race, body mass index, osteoporosis risk factors, or medication use. Women with vertebral fractures had thinner cortices, and larger trabecular area compared to the control group. By ITS analysis, fracture subjects had fewer trabecular plates, less axially aligned trabeculae and less trabecular connectivity at both the radius and the tibia. Fewer trabecular rods were observed at the radius. Whole bone stiffness and trabecular bone stiffness were 18% and 22% lower in women with vertebral fractures at the radius, and 19% and 16% lower at the tibia, compared with controls. The estimated failure load of the radius and tibia were also reduced in the fracture subjects by 13% and 14%, respectively. In summary, postmenopausal women with vertebral fractures had both trabecular and cortical microstructural deterioration at the peripheral skeleton, with a preferential loss of trabecular plates and cortical thinning. These microstructural deficits translated into lower whole bone and trabecular bone stiffness at the radius and tibia. Our results suggest that abnormalities in trabecular plate and rod microstructure may be important mechanisms of vertebral fracture in postmenopausal women.
Collapse
Affiliation(s)
- Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Emily M Stein
- Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | - Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Kyle K Nishiyama
- Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | - Y Eric Yu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Elizabeth Shane
- Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
6
|
Wang J, Zhou B, Liu XS, Fields AJ, Sanyal A, Shi X, Adams M, Keaveny TM, Guo XE. Trabecular plates and rods determine elastic modulus and yield strength of human trabecular bone. Bone 2015; 72:71-80. [PMID: 25460571 PMCID: PMC4282941 DOI: 10.1016/j.bone.2014.11.006] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Revised: 11/10/2014] [Accepted: 11/12/2014] [Indexed: 10/24/2022]
Abstract
The microstructure of trabecular bone is usually perceived as a collection of plate-like and rod-like trabeculae, which can be determined from the emerging high-resolution skeletal imaging modalities such as micro-computed tomography (μCT) or clinical high-resolution peripheral quantitative CT (HR-pQCT) using the individual trabecula segmentation (ITS) technique. It has been shown that the ITS-based plate and rod parameters are highly correlated with elastic modulus and yield strength of human trabecular bone. In the current study, plate-rod (PR) finite element (FE) models were constructed completely based on ITS-identified individual trabecular plates and rods. We hypothesized that PR FE can accurately and efficiently predict elastic modulus and yield strength of human trabecular bone. Human trabecular bone cores from proximal tibia (PT), femoral neck (FN) and greater trochanter (GT) were scanned by μCT. Specimen-specific ITS-based PR FE models were generated for each μCT image and corresponding voxel-based FE models were also generated in comparison. Both types of specimen-specific models were subjected to nonlinear FE analysis to predict the apparent elastic modulus and yield strength using the same trabecular bone tissue properties. Then, mechanical tests were performed to experimentally measure the apparent modulus and yield strength. Strong linear correlations for both elastic modulus (r(2) = 0.97) and yield strength (r(2) = 0.96) were found between the PR FE model predictions and experimental measures, suggesting that trabecular plate and rod morphology adequately captures three-dimensional (3D) microarchitecture of human trabecular bone. In addition, the PR FE model predictions in both elastic modulus and yield strength were highly correlated with the voxel-based FE models (r(2) = 0.99, r(2) = 0.98, respectively), resulted from the original 3D images without the PR segmentation. In conclusion, the ITS-based PR models predicted accurately both elastic modulus and yield strength determined experimentally across three distinct anatomic sites. Trabecular plates and rods accurately determine elastic modulus and yield strength of human trabecular bone.
Collapse
Affiliation(s)
- Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - X Sherry Liu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA; McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
| | - Aaron J Fields
- Department of Orthopaedic Surgery, University of California San Francisco, San Francisco, CA, USA; Department of Mechanical Engineering, University of California Berkeley, Berkeley, CA, USA.
| | - Arnav Sanyal
- Department of Mechanical Engineering, University of California Berkeley, Berkeley, CA, USA.
| | - Xiutao Shi
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Mark Adams
- Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY, USA.
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California Berkeley, Berkeley, CA, USA.
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
7
|
Zhou B, Liu XS, Wang J, Lu XL, Fields AJ, Guo XE. Dependence of mechanical properties of trabecular bone on plate-rod microstructure determined by individual trabecula segmentation (ITS). J Biomech 2013; 47:702-8. [PMID: 24360196 DOI: 10.1016/j.jbiomech.2013.11.039] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Accepted: 11/24/2013] [Indexed: 12/01/2022]
Abstract
Individual trabecula segmentation (ITS) technique can decompose the trabecular bone network into individual trabecular plates and rods and is capable of quantifying the plate/rod-related microstructural characteristics of trabecular bone. This novel technique has been shown to be able to provide in-depth insights into micromechanics and failure mechanisms of human trabecular bone, as well as to distinguish the fracture status independent of area bone mineral density in clinical applications. However, the plate/rod microstructural parameters from ITS have never been correlated to experimentally determined mechanical properties of human trabecular bone. In this study, on-axis cylindrical trabecular bone samples from human proximal tibia (n=22), vertebral body (n=10), and proximal femur (n=21) were harvested, prepared, scanned using micro computed-tomography (µCT), analyzed with ITS and mechanically tested. Regression analyses showed that the plate bone volume fraction (pBV/TV) and axial bone volume fraction (aBV/TV) calculated by ITS analysis correlated the best with elastic modulus (R(2)=0.96-0.97) and yield strength (R(2)=0.95-0.96). Trabecular plate-related microstructural parameters correlated highly with elastic modulus and yield strength, while most rod-related parameters were found inversely and only moderately correlated with the mechanical properties. In addition, ITS analysis also identified that trabecular bone at human femoral neck had the highest trabecular plate-related parameters while the other sites were similar with each other in terms of plate-rod microstructure.
Collapse
Affiliation(s)
- Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - X Sherry Liu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA; McKay Orthopaedic Research Laboratory, University of Pennsylvania, Philadelphia, PA, USA
| | - Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - X Lucas Lu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA; Cartilage Bioengineering Laboratory, Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - Aaron J Fields
- Department of Orthopaedic Surgery, University of California, San Francisco, CA, USA; Orthopaedic Biomechanics Laboratory, Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|