1
|
Zagzoog N, Rastgarjazi S, Ramjist J, Lui J, Hopfgartner A, Jivraj J, Yeretsian T, Zadeh G, Lin V, Yang VXD. Pilot Study of Optical Topographic Imaging Based Neuronavigation for Mastoidectomy. World Neurosurg 2022; 166:e790-e798. [PMID: 35953033 DOI: 10.1016/j.wneu.2022.07.150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 07/21/2022] [Accepted: 07/22/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND Mastoidectomy involves drilling the temporal bone while avoiding the facial nerve, semicircular canals, sigmoid sinus, and tegmen. Optical topographic imaging (OTI) is a novel registration technique that allows rapid registration with minimal navigational error. To date, no studies have examined the use of OTI in skull-base procedures. METHODS In this cadaveric study, 8 mastoidectomies were performed in 2 groups-4 free-hand (FH) and 4 OTI-assisted mastoidectomies. Registration accuracy for OTI navigation was quantified with root mean square (RMS) and target registration error (TRE). Procedural time, percent of mastoid resected, and the proximity of the mastoidectomy cavity to critical structures were determined. RESULTS The average RMS and TRE associated with OTI-based registration were 1.44 mm (±0.83 mm) and 2.17 mm (±0.89 mm), respectively. The volume removed, expressed as a percentage of the total mastoid volume, was 37.5% (±10.2%) versus 31.2% (±2.3%), P = 0.31, for FH and OTI-assisted mastoidectomy. There were no statistically significant differences between FH and OTI-assisted mastoidectomies with respect to proximity to critical structures or procedural time. CONCLUSIONS This work is the first examining the application of OTI neuronavigation in lateral skull-base procedures. This pilot study revealed the RMS and TRE for OTI-based navigation in the lateral skull base are 1.44 mm (±0.83 mm) and 2.17 mm (±0.89 mm), respectively. This pilot study demonstrates that an OTI-based system is sufficiently accurate and may address barriers to widespread adoption of navigation for lateral skull-base procedures.
Collapse
Affiliation(s)
- Nirmeen Zagzoog
- Institute of Medical Science, School of Graduate Studies, Faculty of Medicine, Toronto, Ontario, Canada; Brain Sciences Program/Imaging Research, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada; Division of Neurosurgery, Department of Surgery, McMaster University, Hamilton, Ontario, Canada; Bioengineering and Biophotonics Laboratory, Ryerson University, Toronto, Ontario, Canada.
| | - Siavash Rastgarjazi
- Bioengineering and Biophotonics Laboratory, Ryerson University, Toronto, Ontario, Canada
| | - Joel Ramjist
- Brain Sciences Program/Imaging Research, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada; Bioengineering and Biophotonics Laboratory, Ryerson University, Toronto, Ontario, Canada
| | - Justin Lui
- Department of Otolaryngology - Head and Neck Surgery, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada; Division of Otolaryngology, Head and Neck Surgery, University of Calgary, Calgary, Alberta, Canada
| | - Adam Hopfgartner
- Orthopedic Biomechanics Laboratory, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Jamil Jivraj
- Bioengineering and Biophotonics Laboratory, Ryerson University, Toronto, Ontario, Canada
| | - Tiffany Yeretsian
- Brain Sciences Program/Imaging Research, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Gelareh Zadeh
- Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada; Division of Neurosurgery, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada
| | - Vincent Lin
- Department of Otolaryngology - Head and Neck Surgery, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada; Department of Otolaryngology - Head and Neck Surgery, University of Toronto, Toronto, Ontario, Canada
| | - Victor X D Yang
- Brain Sciences Program/Imaging Research, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada; Bioengineering and Biophotonics Laboratory, Ryerson University, Toronto, Ontario, Canada; Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada; Division of Neurosurgery, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| |
Collapse
|
2
|
Chiragzada S, Hellman E, Michael D, Narayanan R, Nacev A, Kumar D. Initial phantom studies for an office-based low-field MR system for prostate biopsy. Int J Comput Assist Radiol Surg 2021; 16:741-8. [PMID: 33891253 DOI: 10.1007/s11548-021-02364-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 04/01/2021] [Indexed: 11/25/2022]
Abstract
Purpose Prostate cancer is the second most prevalent cancer in US men, with about 192,000 new cases and 33,000 deaths predicted for 2020. With only a 31% 5-year survival rate for patients with an initial diagnosis of stage-four prostate cancer, the necessity for early screening and diagnosis is clear. In this paper, we present navigation accuracy results for Promaxo’s MR system intended to be used in a physician’s office for image-guided transperineal prostate biopsy. Methods The office-based low-field MR system was used to acquire images of prostate phantoms with needles inserted through a transperineal template. Coordinates of the estimated sample core locations in the office-based MR system were compared to ground truth needle coordinates identified in a 1.5T external reference scan. The error was measured as the distance between the planned target and the ground truth core center and as the shortest perpendicular distance between the planned target and the ground truth trajectory of the whole core. Results The average error between the planned target and the ground truth core center was 2.57 ± 1.02 mm, [1.93–3.21] 95% CI. The average error between the planned target to the actual core segment was 2.05 ± 1.24 mm, [1.53–2.56] 95% CI. Conclusion The average navigation errors were below the clinically significant threshold of 5 mm. The initial phantom results demonstrate the feasibility of the office-based system for prostate biopsy.
Collapse
|
3
|
Lin Q, Yang R, Yang L, Chen H, Li B, Cai K. Optimization Model for the Distribution of Fiducial Markers in Liver Intervention. J Med Syst 2020; 44:83. [PMID: 32152742 DOI: 10.1007/s10916-020-01548-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Accepted: 02/18/2020] [Indexed: 10/24/2022]
Abstract
The distribution of fiducial markers is one of the main factors affected the accuracy of optical navigation system. However, many studies have been focused on improving the fiducial registration accuracy or the target registration accuracy, but few solutions involve optimization model for the distribution of fiducial markers. In this paper, we propose an optimization model for the distribution of fiducial markers to improve the optical navigation accuracy. The strategy of optimization model is reducing the distribution from three dimensional to two dimensional to obtain the 2D optimal distribution by using optimization algorithm in terms of the marker number and the expectation equation of target registration error (TRE), and then extend the 2D optimal distribution in two dimensional to three dimensional to calculate the optimal distribution according to the distance parameter and the expectation equation of TRE. The results of the experiments show that the averaged TRE for the human phantom is approximately 1.00 mm by applying the proposed optimization model, and the averaged TRE for the abdominal phantom is 0.59 mm. The experimental results of liver simulator model and ex-vivo porcine liver model show that the proposed optimization model can be effectively applied in liver intervention.
Collapse
|
4
|
Carl B, Bopp M, Saß B, Nimsky C. Intraoperative computed tomography as reliable navigation registration device in 200 cranial procedures. Acta Neurochir (Wien) 2018; 160:1681-9. [PMID: 30051160 DOI: 10.1007/s00701-018-3641-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 07/20/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND Registration accuracy is a main factor influencing overall navigation accuracy. Standard fiducial- or landmark-based patient registration is user dependent and error-prone. Intraoperative imaging offers the possibility for user-independent patient registration. The aim of this paper is to evaluate our initial experience applying intraoperative computed tomography (CT) for navigation registration in cranial neurosurgery, with a special focus on registration accuracy and effective radiation dose. METHODS A total of 200 patients (141 craniotomy, 19 transsphenoidal, and 40 stereotactic burr hole procedures) were investigated by intraoperative CT applying a 32-slice movable CT scanner, which was used for automatic navigation registration. Registration accuracy was measured by at least three skin fiducials that were not part of the registration process. RESULTS Automatic registration resulted in high registration accuracy (mean registration error: 0.93 ± 0.41 mm). Implementation of low-dose scanning protocols did not impede registration accuracy (registration error applying the full dose head protocol: 0.87 ± 0.36 mm vs. the low dose sinus protocol 0.72 ± 0.43 mm) while a reduction of the effective radiation dose by a factor of 8 could be achieved (mean effective radiation dose head protocol: 2.73 mSv vs. sinus protocol: 0.34 mSv). CONCLUSION Intraoperative CT allows highly reliable navigation registration with low radiation exposure.
Collapse
|
5
|
Soteriou E, Grauvogel J, Laszig R, Grauvogel TD. Prospects and limitations of different registration modalities in electromagnetic ENT navigation. Eur Arch Otorhinolaryngol 2016; 273:3979-3986. [PMID: 27149874 DOI: 10.1007/s00405-016-4063-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 04/19/2016] [Indexed: 01/03/2023]
Abstract
The present study examined electromagnetic tracking technology for ENT navigation. Five different registration modalities were compared and navigation accuracy was assessed. Four skull models were individually fabricated with a three-dimensional printer, based on patients' computer tomography datasets. Individual silicone masks were fitted for skin and soft tissue simulation. Five registration modalities were examined: (1) invasive marker, (2) automatic, (3) surface matching (AccuMatch), (4) anatomic landmarks, and (5) oral splint registration. Overall navigation accuracy and accuracy on selected anatomic locations were assessed by targeting 26 titanium screws previously placed over the skull. Overall navigation accuracy differed significantly between all registration modalities. The target registration error was 0.94 ± 0.06 mm (quadratic mean ± standard deviation) for the invasive marker registration, 1.41 ± 0.04 mm for the automatic registration, 1.59 ± 0.14 mm for the surface matching registration, and 5.15 ± 0.66 mm (four landmarks) and 4.37 ± 0.73 mm (five landmarks) for the anatomic landmark registration. Oral splint registration proved itself to be inapplicable to this navigation system. Invasive marker registration was superior on most selected anatomic locations. However, on the ethmoid and sphenoid sinus the automatic registration process revealed significantly lower target registration error values. Only automatic and surface registration met the accuracy requirements for noninvasive registration. Particularly, the automatic image-to-world registration reaches target registration error values on the anterior skull base which are comparable with the gold standard of invasive screw registration.
Collapse
Affiliation(s)
- Eric Soteriou
- Department of Otorhinolaryngology-Head and Neck Surgery, Albert-Ludwigs-University Medical School Freiburg, Killianstr. 5, 79106, Freiburg, Germany
| | - Juergen Grauvogel
- Department of Neurosurgery, Albert-Ludwigs-University Medical School Freiburg, Freiburg, Germany
| | - Roland Laszig
- Department of Otorhinolaryngology-Head and Neck Surgery, Albert-Ludwigs-University Medical School Freiburg, Killianstr. 5, 79106, Freiburg, Germany
| | - Tanja Daniela Grauvogel
- Department of Otorhinolaryngology-Head and Neck Surgery, Albert-Ludwigs-University Medical School Freiburg, Killianstr. 5, 79106, Freiburg, Germany.
| |
Collapse
|