1
|
Pigorsch SU, Kampfer S, Oechsner M, Mayinger MC, Mozes P, Devecka M, Kessel KK, Combs SE, Wilkens JJ. Report on planning comparison of VMAT, IMRT and helical tomotherapy for the ESCALOX-trial pre-study. Radiat Oncol 2020; 15:253. [PMID: 33138837 PMCID: PMC7607845 DOI: 10.1186/s13014-020-01693-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 10/21/2020] [Indexed: 12/12/2022] Open
Abstract
Background The ESCALOX trial was designed as a multicenter, randomized prospective dose escalation study for head and neck cancer. Therefore, feasibility of treatment planning via different treatment planning systems (TPS) and radiotherapy (RT) techniques is essential. We hypothesized the comparability of dose distributions for simultaneous integrated boost (SIB) volumes respecting the constraints by different TPS and RT techniques. Methods CT data sets of the first six patients (all male, mean age: 61.3 years) of the pre-study (up to 77 Gy) were used for comparison of IMRT, VMAT, and helical tomotherapy (HT). Oropharynx was the primary tumor location. Normalization of the three step SIB (77 Gy, 70 Gy, 56 Gy) was D95% = 77 Gy. Coverage (CVF), healthy tissue conformity index (HTCI), conformation number (CN), and dose homogeneity (HI) were compared for PTVs and conformation index (COIN) for parotids. Results All RT techniques achieved good coverage. For SIB77Gy, CVF was best for IMRT and VMAT, HT achieved highest CN followed by VMAT and IMRT. HT reached good HTCI value, and HI compared to both other techniques. For SIB70Gy, CVF was best by IMRT. HTCI favored HT, consequently CN as well. HI was slightly better for HT. For SIB56Gy, CVF resulted comparably. Conformity favors VMAT as seen by HTCI and CN. Dmean of ipsilateral and contralateral parotids favor HT. Conclusion Different TPS for dose escalation reliably achieved high plan quality. Despite the very good results of HT planning for coverage, conformity, and homogeneity, the TPS also achieved acceptable results for IMRT and VMAT. Trial registration ClinicalTrials.gov Identifier: NCT 01212354, EudraCT-No.: 2010-021139-15. ARO: ARO 14-01
Collapse
Affiliation(s)
- Steffi U Pigorsch
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany.
| | - Severin Kampfer
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| | - Markus Oechsner
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| | - Michael C Mayinger
- Department of Radiation Oncology, University Hospital Zurich, Rämistrasse 100, Zurich, Switzerland
| | - Petra Mozes
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| | - Michal Devecka
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| | - Kerstin K Kessel
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| | - Stephanie E Combs
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany.,Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Ingolstädter Landstraße 1, Neuherberg, Germany
| | - Jan J Wilkens
- Department of Radiation Oncology, Technical University of Munich (TUM), School of Medicine, Klinikum Rechts Der Isar, Ismaninger Straße 22, 81675, Munich, Germany
| |
Collapse
|