1
|
López A, García B, Gómez A, González L, González N, Martín L, Jaime G. Concordance of the ions and GAP anion obtained by gasometry vs standard laboratory in critical care. Med Intensiva 2018; 43:521-527. [PMID: 30193741 DOI: 10.1016/j.medin.2018.06.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 06/22/2018] [Accepted: 06/25/2018] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To evaluate the differences observed in ion and GAP anion determinations obtained by point-of-care (POC) blood gas versus laboratory biochemical testing, and to analyze the possible errors according to the limits of normality. MATERIAL AND METHODS A descriptive, cross-sectional retrospective study was made to assess concordance between two diagnostic tests in patients admitted to the Critical Care Unit of Ourense University Hospital Complex (Spain), between July and November 2015, involving at least one coinciding biochemical test and POC determination. Patients under 18years of age were excluded. RESULTS A total of 1,073 samples were analyzed. Lin's concordance correlation coefficients for sodium, potassium and chlorine were 0.87, 0.84 and 0.72, respectively. Kappa concordance of the normality limits for sodium, potassium and chlorine was 0.63, 0.74 and 0.32. The results indicated poor correlation of the anion GAP and null concordance between POC and biochemical testing, including the value corrected for albumin. CONCLUSIONS Poor concordance was observed between the ion values as determined by biochemistry and blood gases; the two methods are therefore not interchangeable. Kappa agreement with normality limits was good for sodium and potassium, and weak for chlorine. Possible validity was noted in orienting the classification within the ion limits, with the exception of chlorine. No agreement was recorded in relation to the anion GAP, even that corrected for albumin.
Collapse
Affiliation(s)
- A López
- Grupo de Investigación en Anestesia y Cuidados Críticos, Instituto de Investigación Sanitaria Galicia SUR (ISS Galicia Sur), SERGAS-UVIGO, Vigo, Pontevedra, España; Servicio de Anestesia y Reanimación, Complexo Hospitalario Universitario de Ourense (CHUO), SERGAS, Ourense, España.
| | - B García
- Grupo de Investigación en Anestesia y Cuidados Críticos, Instituto de Investigación Sanitaria Galicia SUR (ISS Galicia Sur), SERGAS-UVIGO, Vigo, Pontevedra, España; Servicio de Anestesiología, Reanimación y Terapia del Dolor, Hospital Costa del Sol, Marbella, Málaga, España
| | - A Gómez
- Grupo de Investigación en Anestesia y Cuidados Críticos, Instituto de Investigación Sanitaria Galicia SUR (ISS Galicia Sur), SERGAS-UVIGO, Vigo, Pontevedra, España; Servicio de Anestesia y Reanimación, Complexo Hospitalario Universitario de Ourense (CHUO), SERGAS, Ourense, España
| | - L González
- Grupo de Investigación en Anestesia y Cuidados Críticos, Instituto de Investigación Sanitaria Galicia SUR (ISS Galicia Sur), SERGAS-UVIGO, Vigo, Pontevedra, España; Servicio de Anestesia y Reanimación, Complexo Hospitalario Universitario de Ourense (CHUO), SERGAS, Ourense, España
| | - N González
- Grupo de Investigación en Anestesia y Cuidados Críticos, Instituto de Investigación Sanitaria Galicia SUR (ISS Galicia Sur), SERGAS-UVIGO, Vigo, Pontevedra, España; Servicio de Anestesia y Reanimación, Complexo Hospitalario Universitario de Ourense (CHUO), SERGAS, Ourense, España
| | - L Martín
- Grupo de Investigación en Anestesia y Cuidados Críticos, Instituto de Investigación Sanitaria Galicia SUR (ISS Galicia Sur), SERGAS-UVIGO, Vigo, Pontevedra, España; Servicio de Anestesia y Reanimación, Complexo Hospitalario Universitario de Ourense (CHUO), SERGAS, Ourense, España
| | - G Jaime
- Servicio de Análisis Clínicos, Complexo Hospitalario Universitario de Ourense (CHUO), SERGAS, Ourense, España
| |
Collapse
|