1
|
Imam MZ, Kuo A, Ghassabian S, Cai Y, Qin Y, Li T, Smith MT. CYX-5, a G-protein biassed MOP receptor agonist, DOP receptor antagonist and KOP receptor agonist, evokes constipation but not respiratory depression relative to morphine in rats. Pharmacol Rep 2023; 75:634-646. [PMID: 36637684 PMCID: PMC10227131 DOI: 10.1007/s43440-023-00446-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 01/02/2023] [Accepted: 01/03/2023] [Indexed: 01/14/2023]
Abstract
BACKGROUND Strong opioid analgesics such as morphine alleviate moderate to severe acute nociceptive pain (e.g. post-surgical or post-trauma pain) as well as chronic cancer pain. However, they evoke many adverse effects and so there is an unmet need for opioid analgesics with improved tolerability. Recently, a prominent hypothesis has been that opioid-related adverse effects are mediated by β-arrestin2 recruitment at the µ-opioid (MOP) receptor and this stimulated research on discovery of G-protein biassed opioid analgesics. In other efforts, opioids with MOP agonist and δ-opioid (DOP) receptor antagonist profiles are promising for reducing side effects c.f. morphine. Herein, we report on the in vivo pharmacology of a novel opioid peptide (CYX-5) that is a G-protein biassed MOP receptor agonist, DOP receptor antagonist and kappa opioid (KOP) receptor agonist. METHODS Male Sprague-Dawley received intracerebroventricular bolus doses of CYX-5 (3, 10, 20 nmol), morphine (100 nmol) or vehicle, and antinociception (tail flick) was assessed relative to constipation (charcoal meal and castor oil-induced diarrhoea tests) and respiratory depression (whole body plethysmography). RESULTS CYX-5 evoked naloxone-sensitive, moderate antinociception, at the highest dose tested. Although CYX-5 did not inhibit gastrointestinal motility, it reduced stool output markedly in the castor oil-induced diarrhoea test. In contrast to morphine that evoked respiratory depression, CYX-5 increased tidal volume, thereby stimulating respiration. CONCLUSION Despite its lack of recruitment of β-arrestin2 at MOP, DOP and KOP receptors, CYX-5 evoked constipation, implicating a mechanism other than β-arrestin2 recruitment at MOP, DOP and KOP receptors, mediating constipation evoked by CYX-5 and potentially other opioid ligands.
Collapse
Affiliation(s)
- Mohammad Zafar Imam
- School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, St Lucia Campus, Brisbane, QLD, 4072, Australia
| | - Andy Kuo
- School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, St Lucia Campus, Brisbane, QLD, 4072, Australia
| | - Sussan Ghassabian
- School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, St Lucia Campus, Brisbane, QLD, 4072, Australia
| | - Yunxin Cai
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Yajuan Qin
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu, China
| | - Tingyou Li
- School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu, China.
| | - Maree T Smith
- School of Biomedical Sciences, Faculty of Medicine, The University of Queensland, St Lucia Campus, Brisbane, QLD, 4072, Australia.
| |
Collapse
|
2
|
Gawlitza J, Haubenreisser H, Henzler T, Akin I, Schönberg S, Borggrefe M, Trinkmann F. Finding the right spot: Where to measure airway parameters in patients with COPD. Eur J Radiol 2018; 104:87-93. [PMID: 29857872 DOI: 10.1016/j.ejrad.2018.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2018] [Revised: 04/30/2018] [Accepted: 05/03/2018] [Indexed: 11/17/2022]
Abstract
PURPOSE The importance of spirometry for management of COPD was reduced in the 2017 revision of the GOLD report. CT derived airway measurements show strong correlations with lung function tests and symptoms. However, these correlations are specific to the airway localization, and currently there is no evidence for the ideal spot. Therefore, the aim of this prospective study was to systematically correlate CT derived airway measurements with extensive lung function testing. METHODS AND MATERIALS 65 patients with diagnosed COPD underwent body plethysmography, impulse oscillometry and dose optimized qCT examination (Somatom Force, Healthineers, Germany) in inspiration and expiration. Eight airway parameters (e.g. outer diameter, maximal wall thickness) were acquired for both scans in every lobe for the third to fifth generation bronchus and correlated with the lung function tests. RESULTS The most significant correlations between airway parameters were found for the third generation bronchus of the upper left lobe during expiration (25 out of 48 correlation pairs, mean r = -0.39) and for the third generation bronchus of the upper right lobe during inspiration (9 out of 48 correlation pairs, mean r = -0.25). No significant correlations were for example found for the upper right lobe in expiration. CONCLUSION Correlations between airway parameters and lung function tests vary widely between lobes, bronchus generations and breathing states. Our work suggests that the third generation bronchus of the upper left lobe in expiration could be the preferred localization for airway quantification in future studies.
Collapse
Affiliation(s)
- Joshua Gawlitza
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
| | - Holger Haubenreisser
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
| | - Thomas Henzler
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
| | - Ibrahim Akin
- 1st Department of Medicine (Cardiology, Angiology, Pulmonary and Intensive Care), University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Mannheim, Germany.
| | - Stefan Schönberg
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Mannheim, Germany.
| | - Martin Borggrefe
- 1st Department of Medicine (Cardiology, Angiology, Pulmonary and Intensive Care), University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Mannheim, Germany.
| | - Frederik Trinkmann
- 1st Department of Medicine (Cardiology, Angiology, Pulmonary and Intensive Care), University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
| |
Collapse
|
3
|
Kurhanewicz N, Ledbetter A, Farraj A, Hazari M. TRPA1 mediates the cardiac effects of acrolein through parasympathetic dominance but also sympathetic modulation in mice. Toxicol Appl Pharmacol 2018; 347:104-114. [PMID: 29627347 DOI: 10.1016/j.taap.2018.03.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Revised: 02/27/2018] [Accepted: 03/22/2018] [Indexed: 12/12/2022]
Abstract
Numerous studies have demonstrated that short-term air pollution exposure causes cardiac autonomic imbalance as measured by heart rate variability (HRV). We previously showed that a single exposure to acrolein, a ubiquitous gaseous component of air pollution, not only causes autonomic imbalance, but also increases arrhythmia through transient receptor potential A1 (TRPA1) cation channels. Thus, the goal of this study was to characterize acrolein-induced autonomic changes in both normal and TRPA1-knockout mice (KO). Conscious, unrestrained C57BL/6 (WT) and KO mice were exposed to 3 ppm acrolein for 3 h. Separate groups were treated with either atenolol (sympathetic blocker), atropine (parasympathetic blocker) or hexamethonium (autonomic neurotransmission blocker), immediately before exposure. Electrocardiogram (ECG) and heart rate (HR) were recorded continuously before, during and after exposure. Exposure to acrolein produced significant increases in standard deviation of normal-to-normal R-R intervals (SDNN), Root Mean Square of the Successive Differences (RMSSD) and Low-Frequency (LF), as well as an increase in arrhythmia in WT mice. Treatment with atenolol reduced this response while atropine enhanced it, and both drugs blocked the acrolein-induced increase in arrhythmia; hexamethonium had no effect. On the other hand, neither acrolein nor any drug had an effect in the KO mice. Thus, acrolein-induced HRV responses appear to be mediated by a combined parasympathetic and sympathetic modulation. KO mice did not demonstrate any increases in HRV with exposure to acrolein. These data demonstrate that the cardiac effects of irritant air pollutants likely involve disruption of homeostatic balance and altered regulation even in healthy animals.
Collapse
Affiliation(s)
- Nicole Kurhanewicz
- Curriciulm in Toxicology, School of Medicine, University of North Carolina, Chapel Hill, NC 27599, United States
| | - Allen Ledbetter
- Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, NC 27711, United States
| | - Aimen Farraj
- Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, NC 27711, United States
| | - Mehdi Hazari
- Environmental Public Health Division, National Health and Environmental Effects Research Laboratory, US Environmental Protection Agency, Research Triangle Park, NC 27711, United States.
| |
Collapse
|
4
|
Lai YT, Huang YS. Modification and Application of a Commercial Whole-body Plethysmograph to Monitor Respiratory Abnormalities in Neonatal Mice. Bio Protoc 2017; 7:e2343. [PMID: 34541095 DOI: 10.21769/bioprotoc.2343] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 05/18/2017] [Accepted: 05/22/2017] [Indexed: 11/02/2022] Open
Abstract
Proper breathing is essential for mammals to acquire oxygen after birth and requires coordinated actions among several tissues, including diaphragm, intercostal muscles, trachea, bronchi, lung and respiration-regulating neurons located in the medulla oblongata. Genetically modified mice that die early postnatally may have respiratory defects caused by maldevelopment of any one of these tissues (Turgeon and Meloche, 2009). Because of the small body size of neonatal pups, whole-body plethysmography can be used to monitor their respiratory activities. In this protocol, we modified the commercial whole-body plethysmograph by increasing metal filters in the pneumotach, connecting an extension tube to the pneumotach and removing the bias flow supply. With these modifications, the sensitivity of this device is significantly increased to enable the detection of rhythmic respiration in neonatal mice as early as postnatal day 1 (P1).
Collapse
Affiliation(s)
- Yen-Ting Lai
- Institute of Biomedical Sciences, Academia Sinica, 11529, Taipei, Taiwan
| | - Yi-Shuian Huang
- Institute of Biomedical Sciences, Academia Sinica, 11529, Taipei, Taiwan
| |
Collapse
|
5
|
Quindry JC, Ballmann CG, Epstein EE, Selsby JT. Plethysmography measurements of respiratory function in conscious unrestrained mice. J Physiol Sci 2016; 66:157-64. [PMID: 26459291 PMCID: PMC10717823 DOI: 10.1007/s12576-015-0408-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Accepted: 09/25/2015] [Indexed: 10/23/2022]
Abstract
Whole body plethysmography (WBP) is used to quantify pulmonary function in conscious, unrestrained mice. We determined currently whether time of day and environmental lighting influence day-to-day reproducibility of pulmonary function, and quantifed the necessary habituation time in the WBP chamber. Two-month-old male C57BL6 and mdx mice (n = 8/group, reverse light cycle), were examined on consecutive days using a calibrated WBP chamber and manufacturer software was used to calculate respiratory measures. Respiratory data stabilized between 5-10 min for all variables. Mice exhibited time of day respiratory differences, performing more forceful and less frequent breaths midday (11:45 a.m. and 3:00 p.m.) compared to 7:30 a.m. WBP performed in darkened conditions elicited more forceful breathing than lit conditions. Day-to-day reproducibility during controlled conditions ranged from r(2) = 0.58 to 0.62 for the functional measures. Findings indicate reproducible respiratory data are obtainable following a 15-min chamber habituation and standardization of time of day and room lighting.
Collapse
Affiliation(s)
- John C Quindry
- Cardioprotection Laboratory, School of Kinesiology, Auburn University, Auburn, AL, 36830, USA.
| | - Christopher G Ballmann
- Cardioprotection Laboratory, School of Kinesiology, Auburn University, Auburn, AL, 36830, USA
| | - Erin E Epstein
- Cardioprotection Laboratory, School of Kinesiology, Auburn University, Auburn, AL, 36830, USA
| | | |
Collapse
|
6
|
de Mir Messa I, Sardón Prado O, Larramona H, Salcedo Posadas A, Villa Asensi JR. [Body plethysmography (I): Standardisation and quality criteria]. An Pediatr (Barc) 2015; 83:136.e1-7. [PMID: 25797588 DOI: 10.1016/j.anpedi.2014.10.029] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2014] [Accepted: 10/29/2014] [Indexed: 11/24/2022] Open
Abstract
Whole body plethysmography is used to measure lung volumes, capacities and resistances. It is a well standardised technique, and although it is widely used in paediatric chest diseases units, it requires specific equipment, specialist staff, and some cooperation by the patient. Plethysmography uses Boyle's law in order to measure the intrathoracic gas volume or functional residual capacity, and once this is determined, the residual volume and total lung capacity is extrapolated. The measurement of total lung capacity is necessary for the diagnosis of restrictive diseases. Airway resistance is a measurement of obstruction, with the total resistance being able to be measured, which includes chest wall, lung tissue and airway resistance, as well as the specific airway resistance, which is a more stable parameter that is determined by multiplying the measured values of airway resistance and functional residual capacity. The complexity of this technique, the reference equations, the differences in the equipment and their variability, and the conditions in which it is performed, has led to the need for its standardisation. Throughout this article, the practical aspects of plethysmography are analysed, specifying recommendations for performing it, its systematic calibration and the calculations that must be made, as well as the interpretation of the results obtained. The aim of this article is to provide a better understanding of the principles of whole body plethysmography with the aim of optimising the interpretation of the results, leading to improved management of the patient, as well as a consensus among the speciality.
Collapse
Affiliation(s)
- I de Mir Messa
- Sección de Neumología Pediátrica y Fibrosis Quística, Hospital Universitario Vall d́Hebron, Barcelona, España.
| | - O Sardón Prado
- Sección de Neumología Pediátrica, Hospital Universitario Donostia, San Sebastián, Guipúzcoa, España; Departamento de Pediatría, Facultad de Medicina y Odontología, UPV/EHU, San Sebastián, España
| | - H Larramona
- Sección de Neumología Pediátrica, Consorci Hospitalari Parc Taulí, Sabadell, Barcelona, España
| | - A Salcedo Posadas
- Sección de Neumología, Hospital Maternoinfantil Gregorio Marañón, Madrid, España
| | - J R Villa Asensi
- Sección de Neumología, Hospital Infantil Universitario Niño Jesús, Madrid, España
| | | |
Collapse
|