Mesnard T, Pruvot L, Oliver Patterson B, Préville AD, Azzaoui R, Sobocinski J. Early Institutional Experience with One-Piece Bifurcated-Fenestrated Stentgraft in the Treatment of Abdominal Aortic Aneurysms.
J Endovasc Ther 2024;
31:241-247. [PMID:
36112831 DOI:
10.1177/15266028221119612]
[Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
PURPOSE
To review the early experience of the use of a bifurcated-fenestrated endograft (Bif-FEVAR) to treat abdominal aortic aneurysms (AAA) in a high-volume aortic center.
METHODS
A retrospective single-center analysis was conducted between March 2019 and April 2021 including consecutive patients that underwent Bif-FEVAR. Only patients without a proper infrarenal neck and a distance <70 mm between the lowest target artery and the native or prosthetic aortic bifurcation were considered. All Bif-FEVAR custom-made devices were manufactured by Cook Medical (Inc., Bloomington, Indiana). Demographics, anatomical features, technical success, major adverse events, 30-day mortality, and survival according to Kaplan-Meier were analyzed according to Society for Vascular Surgery standards.
RESULTS
Overall, 10 patients (100% male with median age 78) were included. The median preoperative maximal aneurysm diameter was 68 mm [51-84]. Eight patients were treated for a proximal type I endoleak after endovascular aneurysm repair. A total of 36 fenestrations were planned. The median operative time was 144 min [127-168], with a median fluoro time of 40.5 min [34-54] and a median dose area product of 73 Gy cm2 [61-89]. Technical success rate was 100%. No patients experienced a major postoperative adverse event. Median follow-up time was 8 months [6-13].
CONCLUSION
Bif-FEVAR is technically feasible when there is a short distance below the lowest target artery and the aortic bifurcation, with favorable short-term results.
CLINICAL IMPACT
This study assessed the use of an innovative one-piece bifurcated fenestrated stent-graft as a primary procedure or in the treatment of proximal endoleak after standard infrarenal EVAR. We demonstrated these custom-made devices can be used safely with favorable short-term results. One-piece bifurcated fenestrated stent-grafts extend the indications of FEVAR for patients with an unusually short distance between the lowest renal artery and the aorto-iliac bifurcation or the diverter flow of a preexisting bifurcated infrarenal stent-graft.
Collapse