1
|
Hu Y, Nguyen H, Smith C, Chen T, Byrne M, Archibald-Heeren B, Rijken J, Aland T. Clinical assessment of a novel machine-learning automated contouring tool for radiotherapy planning. J Appl Clin Med Phys 2023:e13949. [PMID: 36871161 DOI: 10.1002/acm2.13949] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 12/11/2022] [Accepted: 02/13/2023] [Indexed: 03/06/2023] Open
Abstract
Contouring has become an increasingly important aspect of radiotherapy due to inverse planning. Several studies have suggested that the clinical implementation of automated contouring tools can reduce inter-observer variation while increasing contouring efficiency, thereby improving the quality of radiotherapy treatment and reducing the time between simulation and treatment. In this study, a novel, commercial automated contouring tool based on machine learning, the AI-Rad Companion Organs RT™ (AI-Rad) software (Version VA31) (Siemens Healthineers, Munich, Germany), was assessed against both manually delineated contours and another commercially available automated contouring software, Varian Smart Segmentation™ (SS) (Version 16.0) (Varian, Palo Alto, CA, United States). The quality of contours generated by AI-Rad in Head and Neck (H&N), Thorax, Breast, Male Pelvis (Pelvis_M), and Female Pelvis (Pevis_F) anatomical areas was evaluated both quantitatively and qualitatively using several metrics. A timing analysis was subsequently performed to explore potential time savings achieved by AI-Rad. Results showed that most automated contours generated by AI-Rad were not only clinically acceptable and required minimal editing, but also superior in quality to contours generated by SS in multiple structures. In addition, timing analysis favored AI-Rad over manual contouring, indicating the largest time saving (753s per patient) in the Thorax area. AI-Rad was concluded to be a promising automated contouring solution that generated clinically acceptable contours and achieved time savings, thereby greatly benefiting the radiotherapy process.
Collapse
Affiliation(s)
- Yunfei Hu
- Icon Cancer Centre Concord, Rusty Priest Building, Concord Repatriation Hospital, Concord NSW, Australia
| | | | | | - Tom Chen
- Icon Cancer Centre Springfield, Cancer Care Centre Mater Private Hospital, 30 Health Care Dr, Springfield, Queensland, Australia
| | - Mikel Byrne
- Icon Cancer Centre Wahroonga, Sydney Adventist Hospital, Sydney, Australia
| | - Ben Archibald-Heeren
- Icon Cancer Centre Concord, Rusty Priest Building, Concord Repatriation Hospital, Concord NSW, Australia
| | - James Rijken
- Icon Cancer Centre Windsor Gardens, Windsor Gardens, South Australia, Australia
| | - Trent Aland
- ICON Core Office, South Brisbane QLD, Australia
| |
Collapse
|
2
|
Hernandez S, Nguyen C, Parkes J, Burger H, Rhee DJ, Netherton T, Mumme R, Vega JGDL, Duryea J, Leone A, Paulino AC, Cardenas C, Howell R, Fuentes D, Pollard-Larkin J, Court L. Automating the treatment planning process for 3D-conformal pediatric craniospinal irradiation therapy. Pediatr Blood Cancer 2023; 70:e30164. [PMID: 36591994 DOI: 10.1002/pbc.30164] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 11/23/2022] [Accepted: 11/28/2022] [Indexed: 01/03/2023]
Abstract
PURPOSE Pediatric patients with medulloblastoma in low- and middle-income countries (LMICs) are most treated with 3D-conformal photon craniospinal irradiation (CSI), a time-consuming, complex treatment to plan, especially in resource-constrained settings. Therefore, we developed and tested a 3D-conformal CSI autoplanning tool for varying patient lengths. METHODS AND MATERIALS Autocontours were generated with a deep learning model trained:tested (80:20 ratio) on 143 pediatric medulloblastoma CT scans (patient ages: 2-19 years, median = 7 years). Using the verified autocontours, the autoplanning tool generated two lateral brain fields matched to a single spine field, an extended single spine field, or two matched spine fields. Additional spine subfields were added to optimize the corresponding dose distribution. Feathering was implemented (yielding nine to 12 fields) to give a composite plan. Each planning approach was tested on six patients (ages 3-10 years). A pediatric radiation oncologist assessed clinical acceptability of each autoplan. RESULTS The autocontoured structures' average Dice similarity coefficient ranged from .65 to .98. The average V95 for the brain/spinal canal for single, extended, and multi-field spine configurations was 99.9% ± 0.06%/99.9% ± 0.10%, 99.9% ± 0.07%/99.4% ± 0.30%, and 99.9% ± 0.06%/99.4% ± 0.40%, respectively. The average maximum dose across all field configurations to the brainstem, eyes (L/R), lenses (L/R), and spinal cord were 23.7 ± 0.08, 24.1 ± 0.28, 13.3 ± 5.27, and 25.5 ± 0.34 Gy, respectively (prescription = 23.4 Gy/13 fractions). Of the 18 plans tested, all were scored as clinically acceptable as-is or clinically acceptable with minor, time-efficient edits preferred or required. No plans were scored as clinically unacceptable. CONCLUSION The autoplanning tool successfully generated pediatric CSI plans for varying patient lengths in 3.50 ± 0.4 minutes on average, indicating potential for an efficient planning aid in a resource-constrained settings.
Collapse
Affiliation(s)
- Soleil Hernandez
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.,Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Callistus Nguyen
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jeannette Parkes
- Department of Radiation Oncology, Groote Schuur Hospital and University of Cape Town, Cape Town, South Africa
| | - Hester Burger
- Department Medical Physics, Groote Schuur Hospital and University of Cape Town, Cape Town, South Africa
| | - Dong Joo Rhee
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Tucker Netherton
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.,Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Raymond Mumme
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jean Gumma-De La Vega
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Jack Duryea
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Alexandrea Leone
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Arnold C Paulino
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Carlos Cardenas
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Rebecca Howell
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.,Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - David Fuentes
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.,Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Julianne Pollard-Larkin
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.,Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Laurence Court
- The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, Texas, USA.,Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
3
|
Rauseo E, Omer M, Amir-Khalili A, Sojoudi A, Le TT, Cook SA, Hausenloy DJ, Ang B, Toh DF, Bryant J, Chin CWL, Paiva JM, Fung K, Cooper J, Khanji MY, Aung N, Petersen SE. A Systematic Quality Scoring Analysis to Assess Automated Cardiovascular Magnetic Resonance Segmentation Algorithms. Front Cardiovasc Med 2022; 8:816985. [PMID: 35242820 PMCID: PMC8886212 DOI: 10.3389/fcvm.2021.816985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 12/22/2021] [Indexed: 12/29/2022] Open
Abstract
Background The quantitative measures used to assess the performance of automated methods often do not reflect the clinical acceptability of contouring. A quality-based assessment of automated cardiac magnetic resonance (CMR) segmentation more relevant to clinical practice is therefore needed. Objective We propose a new method for assessing the quality of machine learning (ML) outputs. We evaluate the clinical utility of the proposed method as it is employed to systematically analyse the quality of an automated contouring algorithm. Methods A dataset of short-axis (SAX) cine CMR images from a clinically heterogeneous population (n = 217) were manually contoured by a team of experienced investigators. On the same images we derived automated contours using a ML algorithm. A contour quality scoring application randomly presented manual and automated contours to four blinded clinicians, who were asked to assign a quality score from a predefined rubric. Firstly, we analyzed the distribution of quality scores between the two contouring methods across all clinicians. Secondly, we analyzed the interobserver reliability between the raters. Finally, we examined whether there was a variation in scores based on the type of contour, SAX slice level, and underlying disease. Results The overall distribution of scores between the two methods was significantly different, with automated contours scoring better than the manual (OR (95% CI) = 1.17 (1.07–1.28), p = 0.001; n = 9401). There was substantial scoring agreement between raters for each contouring method independently, albeit it was significantly better for automated segmentation (automated: AC2 = 0.940, 95% CI, 0.937–0.943 vs manual: AC2 = 0.934, 95% CI, 0.931–0.937; p = 0.006). Next, the analysis of quality scores based on different factors was performed. Our approach helped identify trends patterns of lower segmentation quality as observed for left ventricle epicardial and basal contours with both methods. Similarly, significant differences in quality between the two methods were also found in dilated cardiomyopathy and hypertension. Conclusions Our results confirm the ability of our systematic scoring analysis to determine the clinical acceptability of automated contours. This approach focused on the contours' clinical utility could ultimately improve clinicians' confidence in artificial intelligence and its acceptability in the clinical workflow.
Collapse
Affiliation(s)
- Elisa Rauseo
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom
| | | | | | | | - Thu-Thao Le
- National Heart Centre Singapore, Singapore, Singapore
| | - Stuart Alexander Cook
- National Heart Centre Singapore, Singapore, Singapore.,Cardiovascular and Metabolic Disorders Program, Duke-National University of Singapore, Singapore, Singapore
| | - Derek John Hausenloy
- National Heart Centre Singapore, Singapore, Singapore.,Cardiovascular and Metabolic Disorders Program, Duke-National University of Singapore, Singapore, Singapore.,Yong Loo Lin School of Medicine, National University Singapore, Singapore, Singapore.,The Hatter Cardiovascular Institute, University College London, London, United Kingdom.,Cardiovascular Research Center, College of Medical and Health Sciences, Asia University, Taichung, Taiwan
| | - Briana Ang
- National Heart Centre Singapore, Singapore, Singapore
| | | | | | | | | | - Kenneth Fung
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom
| | - Jackie Cooper
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom
| | - Mohammed Yunus Khanji
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.,Department of Cardiology, Newham University Hospital, Barts Health NHS Trust, London, United Kingdom
| | - Nay Aung
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom
| | - Steffen Erhard Petersen
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.,Health Data Research UK, London, United Kingdom.,Alan Turing Institute, London, United Kingdom
| |
Collapse
|
4
|
Dai X, Lei Y, Wynne J, Janopaul-Naylor J, Wang T, Roper J, Curran WJ, Liu T, Patel P, Yang X. Synthetic CT-aided multiorgan segmentation for CBCT-guided adaptive pancreatic radiotherapy. Med Phys 2021; 48:7063-7073. [PMID: 34609745 PMCID: PMC8595847 DOI: 10.1002/mp.15264] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 09/15/2021] [Accepted: 09/17/2021] [Indexed: 12/19/2022] Open
Abstract
PURPOSE The delineation of organs at risk (OARs) is fundamental to cone-beam CT (CBCT)-based adaptive radiotherapy treatment planning, but is time consuming, labor intensive, and subject to interoperator variability. We investigated a deep learning-based rapid multiorgan delineation method for use in CBCT-guided adaptive pancreatic radiotherapy. METHODS To improve the accuracy of OAR delineation, two innovative solutions have been proposed in this study. First, instead of directly segmenting organs on CBCT images, a pretrained cycle-consistent generative adversarial network (cycleGAN) was applied to generating synthetic CT images given CBCT images. Second, an advanced deep learning model called mask-scoring regional convolutional neural network (MS R-CNN) was applied on those synthetic CT to detect the positions and shapes of multiple organs simultaneously for final segmentation. The OAR contours delineated by the proposed method were validated and compared with expert-drawn contours for geometric agreement using the Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95), mean surface distance (MSD), and residual mean square distance (RMS). RESULTS Across eight abdominal OARs including duodenum, large bowel, small bowel, left and right kidneys, liver, spinal cord, and stomach, the geometric comparisons between automated and expert contours are as follows: 0.92 (0.89-0.97) mean DSC, 2.90 mm (1.63-4.19 mm) mean HD95, 0.89 mm (0.61-1.36 mm) mean MSD, and 1.43 mm (0.90-2.10 mm) mean RMS. Compared to the competing methods, our proposed method had significant improvements (p < 0.05) in all the metrics for all the eight organs. Once the model was trained, the contours of eight OARs can be obtained on the order of seconds. CONCLUSIONS We demonstrated the feasibility of a synthetic CT-aided deep learning framework for automated delineation of multiple OARs on CBCT. The proposed method could be implemented in the setting of pancreatic adaptive radiotherapy to rapidly contour OARs with high accuracy.
Collapse
Affiliation(s)
- Xianjin Dai
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Jacob Wynne
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - James Janopaul-Naylor
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Justin Roper
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Walter J Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Pretesh Patel
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, Georgia, USA
| |
Collapse
|