1
|
Günther-Müller S, Azizy R, Strehle S. Droplet Motion Driven by Liquid Dielectrophoresis in the Low-Frequency Range. Micromachines (Basel) 2024; 15:151. [PMID: 38276850 DOI: 10.3390/mi15010151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/09/2024] [Accepted: 01/17/2024] [Indexed: 01/27/2024]
Abstract
Electrohydrodynamic wetting manipulation plays a major role in modern microfluidic technologies such as lab-on-a-chip applications and digital microfluidics. Liquid dielectrophoresis (LDEP) is a common driving mechanism, which induces hydrodynamic motion in liquids by the application of nonhomogeneous electrical fields. Among strategies to analyze droplet movement, systematic research on the influence of different frequencies under AC voltage is missing. In this paper, we therefore present a first study covering the motion characteristics of LDEP-driven droplets of the dielectric liquids ethylene glycol and glycerol carbonate in the driving voltage frequency range from 50 Hz to 1600 Hz. A correlation between the switching speed of LDEP-actuated droplets in a planar electrode configuration and the frequency of the applied voltage is shown. Hereby, motion times of different-sized droplets could be reduced by up to a factor of 5.3. A possible excitation of the droplets within their range of eigenfrequencies is investigated using numerical calculations. The featured fluidic device is designed using larger-sized electrodes rather than typical finger or strip electrodes, which are commonly employed in LDEP devices. The influence of the electrode shape is considered simulatively by studying the electric field gradients.
Collapse
Affiliation(s)
- Sarah Günther-Müller
- Institute of Micro- and Nanotechnologies (IMN) MacroNano®, Microsystems Technology Group, Technische Universität Ilmenau, Max-Planck-Ring 12, 98693 Ilmenau, Germany
| | - Raschid Azizy
- Institute of Micro- and Nanotechnologies (IMN) MacroNano®, Microsystems Technology Group, Technische Universität Ilmenau, Max-Planck-Ring 12, 98693 Ilmenau, Germany
| | - Steffen Strehle
- Institute of Micro- and Nanotechnologies (IMN) MacroNano®, Microsystems Technology Group, Technische Universität Ilmenau, Max-Planck-Ring 12, 98693 Ilmenau, Germany
| |
Collapse
|
2
|
Xu M, Vidler C, Wang J, Chen X, Pan Z, Harley WS, Lee PVS, Collins DJ. Micro-Acoustic Holograms for Detachable Microfluidic Devices. Small 2024:e2307529. [PMID: 38174594 DOI: 10.1002/smll.202307529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 11/24/2023] [Indexed: 01/05/2024]
Abstract
Acoustic microfluidic devices have advantages for diagnostic applications, therapeutic solutions, and fundamental research due to their contactless operation, simple design, and biocompatibility. However, most acoustofluidic approaches are limited to forming simple and fixed acoustic patterns, or have limited resolution. In this study,a detachable microfluidic device is demonstrated employing miniature acoustic holograms to create reconfigurable, flexible, and high-resolution acoustic fields in microfluidic channels, where the introduction of a solid coupling layer makes these holograms easy to fabricate and integrate. The application of this method to generate flexible acoustic fields, including shapes, characters, and arbitrarily rotated patterns, within microfluidic channels, is demonstrated.
Collapse
Affiliation(s)
- Mingxin Xu
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Callum Vidler
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Jizhen Wang
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Xi Chen
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Zijian Pan
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - William S Harley
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Peter V S Lee
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
- Graeme Clarke Institute, University of Melbourne, Parkville, Victoria, 3052, Australia
| | - David J Collins
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
- Graeme Clarke Institute, University of Melbourne, Parkville, Victoria, 3052, Australia
| |
Collapse
|
3
|
Gucluer S. A Miniaturized Archimedean Screw Pump for High-Viscosity Fluid Pumping in Microfluidics. Micromachines (Basel) 2023; 14:1409. [PMID: 37512720 PMCID: PMC10384537 DOI: 10.3390/mi14071409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 07/05/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023]
Abstract
Microfluidic devices have revolutionized the field of lab-on-a-chip by enabling precise manipulation of small fluid volumes for various biomedical applications. However, most existing microfluidic pumps struggle to handle high-viscosity fluids, limiting their applicability in certain areas that involve bioanalysis and on-chip sample processing. In this paper, the design and fabrication of a miniaturized Archimedean screw pump for pumping high-viscosity fluids within microfluidic channels are presented. The pump was 3D-printed and operated vertically, allowing for continuous and directional fluid pumping. The pump's capabilities were demonstrated by successfully pumping polyethylene glycol (PEG) solutions that are over 100 times more viscous than water using a basic mini-DC motor. Efficient fluid manipulation at low voltages was achieved by the pump, making it suitable for point-of-care and field applications. The flow rates of water were characterized, and the effect of different screw pitch lengths on the flow rate was investigated. Additionally, the pump's capacity for pumping high-viscosity fluids was demonstrated by testing it with PEG solutions of increasing viscosity. The microfluidic pump's simple fabrication and easy operation position it as a promising candidate for lab-on-a-chip applications involving high-viscosity fluids.
Collapse
Affiliation(s)
- Sinan Gucluer
- Department of Mechanical Engineering, Aydin Adnan Menderes University, Aydin 09010, Turkey
| |
Collapse
|
4
|
Shen S, Wang X, Niu Y. Multi-Vortex Regulation for Efficient Fluid and Particle Manipulation in Ultra-Low Aspect Ratio Curved Microchannels. Micromachines (Basel) 2021; 12:mi12070758. [PMID: 34199145 PMCID: PMC8303296 DOI: 10.3390/mi12070758] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Revised: 06/02/2021] [Accepted: 06/23/2021] [Indexed: 01/02/2023]
Abstract
Inertial microfluidics enables fluid and particle manipulation for biomedical and clinical applications. Herein, we developed a simple semicircular microchannel with an ultra-low aspect ratio to interrogate the unique formations of the helical vortex and Dean vortex by introducing order micro-obstacles. The purposeful and powerful regulation of dimensional confinement in the microchannel achieved significantly improved fluid mixing effects and fluid and particle manipulation in a high-throughput, highly efficient and easy-to-use way. Together, the results offer insights into the geometry-induced multi-vortex mechanism, which may contribute to simple, passive, continuous operations for biochemical and clinical applications, such as the detection and isolation of circulating tumor cells for cancer diagnostics.
Collapse
Affiliation(s)
- Shaofei Shen
- Correspondence: (S.S.); (Y.N.); Tel./Fax: +86-354-6287205 (S.S. & Y.N.)
| | | | - Yanbing Niu
- Correspondence: (S.S.); (Y.N.); Tel./Fax: +86-354-6287205 (S.S. & Y.N.)
| |
Collapse
|
5
|
Kim TH, Hahn YK, Kim MS. Recent Advances of Fluid Manipulation Technologies in Microfluidic Paper-Based Analytical Devices (μPADs) toward Multi-Step Assays. Micromachines (Basel) 2020; 11:mi11030269. [PMID: 32143468 PMCID: PMC7142896 DOI: 10.3390/mi11030269] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Revised: 02/27/2020] [Accepted: 03/03/2020] [Indexed: 12/16/2022]
Abstract
Microfluidic paper-based analytical devices (μPADs) have been suggested as alternatives for developing countries with suboptimal medical conditions because of their low diagnostic cost, high portability, and disposable characteristics. Recently, paper-based diagnostic devices enabling multi-step assays have been drawing attention, as they allow complicated tests, such as enzyme-linked immunosorbent assay (ELISA) and polymerase chain reaction (PCR), which were previously only conducted in the laboratory, to be performed on-site. In addition, user convenience and price of paper-based diagnostic devices are other competitive points over other point-of-care testing (POCT) devices, which are more critical in developing countries. Fluid manipulation technologies in paper play a key role in realizing multi-step assays via μPADs, and the expansion of biochemical applications will provide developing countries with more medical benefits. Therefore, we herein aimed to investigate recent fluid manipulation technologies utilized in paper-based devices and to introduce various approaches adopting several principles to control fluids on papers. Fluid manipulation technologies are classified into passive and active methods. While passive valves are structurally simple and easy to fabricate, they are difficult to control in terms of flow at a specific spatiotemporal condition. On the contrary, active valves are more complicated and mostly require external systems, but they provide much freedom of fluid manipulation and programmable operation. Both technologies have been revolutionized in the way to compensate for their limitations, and their advances will lead to improved performance of μPADs, increasing the level of healthcare around the world.
Collapse
Affiliation(s)
| | - Young Ki Hahn
- Biomedical Convergence Science & Technology, Industrial Technology Advances, Kyungpook National University, 80 Daehakro, Bukgu, Daegu 41566, Korea
- Correspondence: (Y.K.H.); (M.S.K.); Tel.: +82-53-950-2338 (Y.K.H.); +82-53-785-1740 (M.S.K.)
| | - Minseok S. Kim
- Department of New Biology, Daegu Gyeongbuk Institute of Science & Technology (DGIST), 333 Techno jungang-daero, Daegu 42988, Korea
- Correspondence: (Y.K.H.); (M.S.K.); Tel.: +82-53-950-2338 (Y.K.H.); +82-53-785-1740 (M.S.K.)
| |
Collapse
|
6
|
Abstract
In microfluidic devices, it is necessary to propel samples and reagents from one part of the device to another, stir fluids, and detect the presence of chemical and biological targets. Given the small size of these devices, the above tasks are far from trivial. Magnetohydrodynamics (MHD) offers an elegant means to control fluid flow in microdevices without a need for mechanical components. In this paper, we review the theory of MHD for low conductivity fluids and describe various applications of MHD such as fluid pumping, flow control in fluidic networks, fluid stirring and mixing, circular liquid chromatography, thermal reactors, and microcoolers.
Collapse
Affiliation(s)
- Shizhi Qian
- Department of Aerospace Engineering, Old Dominion University, Norfolk, VA 23529-0247, USA
| | - Haim H. Bau
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104-6315, USA
| |
Collapse
|