1
|
Lu Q, Kong L, Peng G, Jia W, Jin S, Dai C, Zhu Q. Algorithm for Automatic Rod Feeding and Positioning Error Compensation for Underground Drilling Robots in Coal Mines. Sensors (Basel) 2023; 23:7530. [PMID: 37687984 PMCID: PMC10490727 DOI: 10.3390/s23177530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 08/19/2023] [Accepted: 08/28/2023] [Indexed: 09/10/2023]
Abstract
In the pursuit of automating the entire underground drilling process in coal mines, the automatic rod feeding technology of drilling robots plays a crucial role. However, the current lack of positional accuracy in automatic rod feeding leads to frequent accidents. To address this issue, this paper presents an algorithm for compensating positioning errors in automatic rod feeding. The algorithm is based on a theoretical mathematical model and manual teaching methods. To enhance the positioning accuracy, we first calibrate the pull rope sensor to correct its measurement precision. Subsequently, we establish a theoretical mathematical model for rod feeding positions by employing spatial coordinate system transformations. We determine the target rod feeding position using a manual teaching-based approach. Furthermore, we analyze the relationship between the theoretical rod delivery position and the target rod delivery position and propose an anisotropic spatial difference compensation technique that considers both distance and direction. Finally, we validate the feasibility of our proposed algorithm through automatic rod feeding tests conducted on a coal mine underground drilling robot. The results demonstrate that our algorithm significantly improves the accuracy of rod feeding positions for coal mine underground drilling robots.
Collapse
Affiliation(s)
- Qianhai Lu
- School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology, Xi’an 710048, China
- CCTEG Xi’an Research Institute (Group) Co., Ltd., Xi’an 710077, China
| | - Lingfei Kong
- School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology, Xi’an 710048, China
| | - Guangyu Peng
- CCTEG Xi’an Research Institute (Group) Co., Ltd., Xi’an 710077, China
| | - Wang Jia
- CCTEG Xi’an Research Institute (Group) Co., Ltd., Xi’an 710077, China
| | - Sun Jin
- School of Mechanical and Precision Instrument Engineering, Xi’an University of Technology, Xi’an 710048, China
| | - Chenyu Dai
- CCTEG Xi’an Research Institute (Group) Co., Ltd., Xi’an 710077, China
| | - Qianxiang Zhu
- CCTEG Xi’an Research Institute (Group) Co., Ltd., Xi’an 710077, China
| |
Collapse
|
2
|
Wan B, Luo S, Feng X, Qin W, Sun H, Hou L, Zhang K, Zhou SWZ, Xiao Z, Chen D, Feng Q, Wang X, Huan F, Bi N, Wang J. Corrigendum: Superiority of integrated cervicothoracic immobilization in the setup of lung cancer patients treated with supraclavicular station irradiation. Front Oncol 2023; 13:1276782. [PMID: 37692842 PMCID: PMC10491891 DOI: 10.3389/fonc.2023.1276782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Accepted: 08/14/2023] [Indexed: 09/12/2023] Open
Abstract
[This corrects the article DOI: 10.3389/fonc.2023.1135879.].
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | | | - Nan Bi
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianyang Wang
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
3
|
Hirotaki K, Tomizawa K, Moriya S, Ito M, Sakae T. Impact of Anatomical Position Errors on Dose Distribution in Head and Neck Radiotherapy and Robust Image Registration Against Anatomical Changes. Anticancer Res 2023; 43:1827-1834. [PMID: 36974799 DOI: 10.21873/anticanres.16336] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/05/2023] [Accepted: 02/09/2023] [Indexed: 03/29/2023]
Abstract
BACKGROUND/AIM This study pursued two goals: Firstly, to search for anatomical structures strongly correlating with dose deterioration, and secondly to investigate the effectiveness of image registration focusing on critical anatomy by comparing it with a conventional method. The aim was to achieve robust image registration to correct for anatomical changes during treatment. PATIENTS AND METHODS Twenty patients with head and neck cancer were enrolled, and 68 simulation computed tomography (CT) and rescan CT image sets were retrospectively analyzed. Forty volumetric-modulated arc therapy and intensity-modulated proton therapy plans were generated and recalculated according to the rescan CT to evaluate the dose effects of anatomical changes. Correlation coefficients were calculated for the relationships between the six-axis motion of the anatomy and the dose indices for the clinical target volume (CTV) and organs at risk. In the image registration, we compared a conventional method and target-based registration that limited the registration range to the CTV and vertebrae. RESULTS The CTV coverage and spinal cord dose were correlated with the position error associated with the pitch and vertical position of the vertebrae, and the parotid gland and oral cavity dose were strongly correlated with the position error associated with the roll of the clivus and mandible. The target registration improved CTV coverage and suppressed the increase in dose to organs at risk compared with conventional methods. CONCLUSION Monitoring vertebral alignment, the assessment and correction of positioning errors associated with the clivus and mandible position errors are important to ensure the quality of daily treatment. Target-based registration may allow for more robust image registration.
Collapse
Affiliation(s)
- Kouta Hirotaki
- Doctoral Program in Medical Sciences, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki, Japan
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba, Japan
| | - Kento Tomizawa
- Department of Radiation Oncology, National Cancer Center Hospital East, Chiba, Japan;
| | | | - Masashi Ito
- Department of Radiological Technology, National Cancer Center Hospital East, Chiba, Japan
| | - Takeji Sakae
- Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| |
Collapse
|
4
|
Wan B, Luo S, Feng X, Qin W, Sun H, Hou L, Zhang K, Wu S, Zhou Z, Xiao Z, Chen D, Feng Q, Wang X, Huan F, Bi N, Wang J. Superiority of integrated cervicothoracic immobilization in the setup of lung cancer patients treated with supraclavicular station irradiation. Front Oncol 2023; 13:1135879. [PMID: 37020878 PMCID: PMC10067865 DOI: 10.3389/fonc.2023.1135879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Accepted: 03/01/2023] [Indexed: 03/22/2023] Open
Abstract
Objective To investigate the superiority of the integrated cervicothoracic immobilization devices (ICTID) on the mobility of the supraclavicular station in lung cancer patients requiring both primary lung lesion and positive supraclavicular lymph nodes irradiation. Methods One hundred patients with lung cancer were prospectively enrolled in the study. The following four different fixation methods are used for CT simulation positioning: thoracoabdominal flat immobilization device fixation with arms lifting (TAFID group), head-neck-shoulder immobilization device fixation with arms on the body sides (HNSID group), ICTID fixation with arms on the body sides (ICTID arms-down group), and n ICTID fixation with arms lifting (ICTID arms-up group). Cone-beam computed tomography (CBCT) images are taken daily or weekly before treatment, to assess anatomical changes during the radiotherapy course. Results The translation errors in X (left-right direction), Y (head-foot direction), and Z (abdomen-back direction) directions of the ICTID arms-up, TAFID, ICTID arms-down and HNSID groups were (0.15 ± 0.18) cm, (0.15 ± 0.16) cm, (0.16 ± 0.16) cm, and (0.15 ± 0.20) cm; (0.15 ± 0.15) cm, (0.21 ± 0.25) cm, (0.28 ± 0.23) cm, and (0.27 ± 0.21) cm; (0.13 ± 0.14) cm, (0.15 ± 0.14) cm, (0.17 ± 0.13) cm, and (0.16 ± 0.14) cm, respectively. Among them, the ICTID arms-up group had the minimal setup errors in X direction than those in ICTID arms-down (p=0.001) and HNSID groups (p=0.001), and in Y direction than those in TAFID (p<0.001), and in Z direction than those in ICTID arms-down (p<0.001) and TAFID groups (p=0.034). For the rotational errors of the four groups in the directions of sagittal plane, transverse plane, and coronal plane, the ICTID arms-up group had the smallest setup errors in the sagittal plane than that of TAFID groups and similar rotation setup errors with those of the other three groups. Conclusion For patients requiring radiation of primary lung lesion and positive supraclavicular lymph nodes, an integrated frame fixation device is preferred the ICTID arms-up methods provide the smallest set up error and satisfied repeatability of body position, compared with TAFID and HNSID.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | - Nan Bi
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianyang Wang
- Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
5
|
Martin-Escalona I, Zola E. Improving Fingerprint-Based Positioning by Using IEEE 802.11mc FTM/RTT Observables. Sensors (Basel) 2022; 23:267. [PMID: 36616863 PMCID: PMC9824134 DOI: 10.3390/s23010267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 12/14/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
Received signal strength (RSS) has been one of the most used observables for location purposes due to its availability at almost every wireless device. However, the volatile nature of RSS tends to yield to non-reliable location solutions. IEEE 802.11mc enabled the use of the round trip time (RTT) for positioning, which is expected to be a more consistent observable for location purposes. This approach has been gaining support from several companies such as Google, which introduced that feature in the Android O.S. As a result, RTT estimation is now available in several recent off-the-shelf devices, opening a wide range of new approaches for computing location. However, RTT has been traditionally addressed to multilateration solutions. Few works exist that assess the feasibility of the RTT as an accurate feature in positioning methods based on classification algorithms. An attempt is made in this paper to fill this gap by investigating the performance of several classification models in terms of accuracy and positioning errors. The performance is assessed using different AP layouts, distinct AP vendors, and different frequency bands. The accuracy and precision of the RTT-based position estimation is always better than the one obtained with RSS in all the studied scenarios, and especially when few APs are available. In addition, all the considered ML algorithms perform pretty well. As a result, it is not necessary to use more complex solutions (e.g., SVM) when simpler ones (e.g., nearest neighbor classifiers) achieve similar results both in terms of accuracy and location error.
Collapse
|
6
|
Song Y, Peng J, Chen Q, Luo H. Compare of Interfractional Setup Reproducibility Between Vacuum-Lock Bag and Thermoplastic Mask in Radiotherapy for Breast Cancer. Technol Cancer Res Treat 2021; 20:15330338211043037. [PMID: 34554027 PMCID: PMC8490727 DOI: 10.1177/15330338211043037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Background: This study aimed to analyze the difference of setup
reproducibility between Vacuum-lock bag and Thermoplastic mask in the
radiotherapy for breast cancer. Methods: A total of 100 invasive
breast carcinoma patients were collected, among whom 50 patients were
immobilized with Vacuum-lock bag (VB group), and the other 50 patients were
immobilized with Thermoplastic mask (TM group). Set up reproducibility in
different axes and comfort levels between two groups at three treatment progress
points during the radiation therapy were collected and analyzed.
Results: The linear regression model showed that fixed device
was an independent factor of radiotherapy setup error (SE). Further subgroup
analysis based on different axes showed that the SE caused by the fixed device
was obvious in all directions. The comfort level in the VB group was
significantly larger than that in the TM group at the beginning of treatment,
reduced as the treatment progress going on, and finally disappeared within three
weeks. Conclusions: Thermoplastic mask could significantly reduce
positioning errors in the radiotherapy of breast cancer. Although more
discomfort was found in the TM group, it could be eliminated as the treatment
progresses.
Collapse
Affiliation(s)
- Yaqi Song
- The Affiliated Huaian No.1 People’s Hospital of Nanjing Medical
University, Huaian, Jiangsu, China
| | - Jin Peng
- The Affiliated Huaian No.1 People’s Hospital of Nanjing Medical
University, Huaian, Jiangsu, China
| | - Qianfeng Chen
- The Affiliated Huaian No.1 People’s Hospital of Nanjing Medical
University, Huaian, Jiangsu, China
| | - Honglei Luo
- The Affiliated Huaian No.1 People’s Hospital of Nanjing Medical
University, Huaian, Jiangsu, China
- Honglei Luo, Department of Radiation
Oncology, The Affiliated Huaian No.1 People’s Hospital of Nanjing Medical
University, Jiangsu, Huaian 223300, China.
| |
Collapse
|
7
|
Lu Y, Ji S, Tu R, Weng D, Lu X, Chen W. An Improved Long-Period Precise Time-Relative Positioning Method Based on RTS Data. Sensors (Basel) 2020; 21:s21010053. [PMID: 33374254 PMCID: PMC7794687 DOI: 10.3390/s21010053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/19/2020] [Accepted: 12/21/2020] [Indexed: 11/29/2022]
Abstract
The high precision positioning can be easily achieved by using real-time kinematic (RTK) and precise point positioning (PPP) or their augmented techniques, such as network RTK (NRTK) and PPP-RTK, even if they also have their own shortfalls. A reference station and datalink are required for RTK or NRTK. Though the PPP technique can provide high accuracy position data, it needs an initialisation time of 10–30 min. The time-relative positioning method estimates the difference between positions at two epochs by means of a single receiver, which can overcome these issues within short period to some degree. The positioning error significantly increases for long-period precise positioning as consequence of the variation of various errors in GNSS (Global Navigation Satellite System) measurements over time. Furthermore, the accuracy of traditional time-relative positioning is very sensitive to the initial positioning error. In order to overcome these issues, an improved time-relative positioning algorithm is proposed in this paper. The improved time-relative positioning method employs PPP model to estimate the parameters of current epoch including position vector, float ionosphere-free (IF) ambiguities, so that these estimated float IF ambiguities are used as a constraint of the base epoch. Thus, the position of the base epoch can be estimated by means of a robust Kalman filter, so that the position of the current epoch with reference to the base epoch can be obtained by differencing the position vectors between the base epoch and the current one. The numerical results obtained during static and dynamic tests show that the proposed positioning algorithm can achieve a positioning accuracy of a few centimetres in one hour. As expected, the positioning accuracy is highly improved by combining GPS, BeiDou and Galileo as a consequence of a higher amount of used satellites and a more uniform geometrical distribution of the satellites themselves. Furthermore, the positioning accuracy achieved by using the positioning algorithm here described is not affected by the initial positioning error, because there is no approximation similar to that of the traditional time-relative positioning. The improved time-relative positioning method can be used to provide long-period high precision positioning by using a single dual-frequency (L1/L2) satellite receiver.
Collapse
Affiliation(s)
- Yangwei Lu
- National Time Service Center, Chinese Academy of Sciences, Shu Yuan Road, Xi’an 710600, China; (Y.L.); (R.T.); (X.L.)
| | - Shengyue Ji
- Department of Surveying and Mapping, China University of Petroleum (East China), Qingdao 266580, China;
| | - Rui Tu
- National Time Service Center, Chinese Academy of Sciences, Shu Yuan Road, Xi’an 710600, China; (Y.L.); (R.T.); (X.L.)
| | - Duojie Weng
- Shenzhen Research Institute, The Hong Kong Polytechnic University, Shenzhen 518057, China;
- Correspondence:
| | - Xiaochun Lu
- National Time Service Center, Chinese Academy of Sciences, Shu Yuan Road, Xi’an 710600, China; (Y.L.); (R.T.); (X.L.)
| | - Wu Chen
- Shenzhen Research Institute, The Hong Kong Polytechnic University, Shenzhen 518057, China;
- Department of Land Surveying and Geo-Informatics, The Hong Kong Polytechnic University, Hong Kong 999077, China
| |
Collapse
|
8
|
Rychlicki M, Kasprzyk Z, Rosiński A. Analysis of Accuracy and Reliability of Different Types of GPS Receivers. Sensors (Basel) 2020; 20:E6498. [PMID: 33203054 DOI: 10.3390/s20226498] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 11/08/2020] [Accepted: 11/11/2020] [Indexed: 11/16/2022]
Abstract
There are several known cases of positioning error, leading to serious consequences, sometimes also deadly. Therefore, obtaining accurate position data by means of GPS receivers is paramount. With this perspective, the aim of this study was to test the within-field accuracy of different types of GPS receivers, and to determine their reliability. A proprietary software was used to determine the positioning accuracy of nine different types of satellite receivers. In addition, their reliability was investigated, by including tests aimed at measuring their positioning accuracy in field conditions. Thus, it was possible to determine the probability that these GPS receivers can be in some states (reliability). The developed software solution could be used for further research on a wider group of the same types of satellite receivers. The results of this study could lead to draft a procedure for evaluating and selecting GPS receivers, based on their quality, prior to use. This could have a paramount importance for uses in special purpose vehicles or transport telematics systems.
Collapse
|
9
|
Zhu Q, Zheng H, Wang Y, Cao Y, Guo S. Study on the Evaluation Method of Sound Phase Cloud Maps Based on an Improved YOLOv4 Algorithm. Sensors (Basel) 2020; 20:E4314. [PMID: 32748865 DOI: 10.3390/s20154314] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 07/27/2020] [Accepted: 07/30/2020] [Indexed: 11/21/2022]
Abstract
Most sound imaging instruments are currently used as measurement tools which can provide quantitative data, however, a uniform method to directly and comprehensively evaluate the results of combining acoustic and optical images is not available. Therefore, in this study, we define a localization error index for sound imaging instruments, and propose an acoustic phase cloud map evaluation method based on an improved YOLOv4 algorithm to directly and objectively evaluate the sound source localization results of a sound imaging instrument. The evaluation method begins with the image augmentation of acoustic phase cloud maps obtained from the different tests of a sound imaging instrument to produce the dataset required for training the convolutional network. Subsequently, we combine DenseNet with existing clustering algorithms to improve the YOLOv4 algorithm to train the neural network for easier feature extraction. The trained neural network is then used to localize the target sound source and its pseudo-color map in the acoustic phase cloud map to obtain a pixel-level localization error. Finally, a standard chessboard grid is used to obtain the proportional relationship between the size of the acoustic phase cloud map and the actual physical space distance; then, the true lateral and longitudinal positioning error of sound imaging instrument can be obtained. Experimental results show that the mean average precision of the improved YOLOv4 algorithm in acoustic phase cloud map detection is 96.3%, the F1-score is 95.2%, and detection speed is up to 34.6 fps. The improved algorithm can rapidly and accurately determine the positioning error of sound imaging instrument, which can be used to analyze and evaluate the positioning performance of sound imaging instrument.
Collapse
|
10
|
Spinsante S, Stallo C. Hybridized-GNSS Approaches to Train Positioning: Challenges and Open Issues on Uncertainty. Sensors (Basel) 2020; 20:s20071885. [PMID: 32235292 PMCID: PMC7181200 DOI: 10.3390/s20071885] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 03/24/2020] [Accepted: 03/25/2020] [Indexed: 12/01/2022]
Abstract
In recent years, the development of advanced systems and applications has propelled the adoption of autonomous railway traffic and train positioning, with several ongoing initiatives and experimental testbeds aimed at proving the suitability and reliability of the Global Navigation Satellite System signals and services, in this specific application domain. To satisfy the strict safety and accuracy requirements aimed at assuring the position solution’s integrity, availability, accuracy and reliability, recent proposals suggest the hybridization of the Global Navigation Satellite System with other technologies. The integration with localization techniques that are expected to be available with the upcoming fifth generation mobile communication networks is among the most promising approaches. In this work, different approaches to the design of hybrid positioning solutions for the railway sector are examined, under the perspective of the uncertainty evaluation of the attained results and performance. In fact, the way the uncertainty associated to the positioning measurements performed by different studies is reported is often not consistent with the Guide to the Expression of Uncertainty in Measurement, and this makes it very difficult to fairly compare the different approaches in order to identify the best emerging solution. Under this perspective, the review provided by this work highlights a number of open issues that should drive future research activities in this field.
Collapse
Affiliation(s)
- Susanna Spinsante
- Dipartimento di Ingegneria dell’Informazione, Università Politecnica delle Marche, Via Brecce Bianche 12, 60131 Ancona, Italy
- Correspondence: ; Tel.: +39-071-220-4102
| | | |
Collapse
|
11
|
Qiu G, Song X, Zhang X, Tu J, Chen T. Pure SH1 Guided-Wave Generation Method with Dual Periodic-Permanent-Magnet Electromagnetic Acoustic Transducers for Plates Inspection. Sensors (Basel) 2019; 19:E3019. [PMID: 31323975 DOI: 10.3390/s19133019] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 07/04/2019] [Accepted: 07/05/2019] [Indexed: 11/16/2022]
Abstract
High frequency guided-waves offer a trade-off between the high sensitivity of local bulk ultrasonic thickness measurements and the large area scanning of lower frequency guided-waves, so it has been a growing interest for corrosion inspection with the dispersive SH1 mode. However, according to the dispersive curve, it is hard to generate the pure SH1 mode since the non-dispersive SH0 mode will be excited simultaneously. Thus, this paper investigates a transducer design method to generate a pure SH1 guided-wave, where the dual periodic-permanent-magnet electromagnetic acoustic transducers (PPM EMATs) are placed on exactly opposite positions either side of the plate symmetrically. The suppression effect for SH0 and the enhancement effect for SH1 of the dual PPM EMATs are mainly discussed by theoretical analysis and simulation analysis, and the influence of positioning errors of PPM EMATs placed on opposite sides of the plate on its performances are analyzed. Employing the proposed dual PPM EMATs, some experiments are performed to verify the reliability of finite element simulation. The results indicate that the dual PPM EMATs can suppress the SH0 mode and generate the pure SH1 mode effectively. Moreover, the longitudinal and lateral positioning errors can affect the dual PPM EMATs performances significantly.
Collapse
|
12
|
Popoola OR, Sinanović S, Ramirez-Iniguez R, Popoola WO. LED-based indoor positioning system using novel optical pixelation technique. Healthc Technol Lett 2019; 6:76-81. [PMID: 31341632 PMCID: PMC6595537 DOI: 10.1049/htl.2018.5039] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 02/20/2019] [Accepted: 04/04/2019] [Indexed: 11/20/2022] Open
Abstract
At present, about 47 million people worldwide have Alzheimer's disease (AD), and because there is no treatment currently available to cure AD, people with AD (PWAD) are cared for. The estimated cost of care for PWAD in 2016 alone is about $236 billion, which puts a huge burden on relatives of PWAD. This work aims to reduce this burden by proposing an inexpensive indoor positioning system that can be used to monitor PWAD. For the positioning, freeform lenses are used to enable a novel optically pixeled LED luminaire (OPLL) that focuses beams from LEDs to various parts of a room, thereby creating uniquely identifiable regions which are used to improve positioning accuracy. Monte Carlo simulation with the designed OPLL in a room with dimensions 5 m × 5 m × 3 m is used to compute the positioning error and theoretical analysis and experiments are used to validate the time for positioning. Results show that by appropriate LED beam design, OPLL has a positioning error and time for positioning of 0.735 m and 187 ms which is 55.1% lower and 1.2 times faster than existing multiple LED estimation model proximity systems.
Collapse
Affiliation(s)
- Olaoluwa R. Popoola
- School of Engineering and Built Environment, Glasgow Caledonian University, Glasgow, G4 0BA, UK
| | - Sinan Sinanović
- School of Engineering and Built Environment, Glasgow Caledonian University, Glasgow, G4 0BA, UK
| | - Roberto Ramirez-Iniguez
- School of Engineering and Built Environment, Glasgow Caledonian University, Glasgow, G4 0BA, UK
| | - Wasiu O. Popoola
- Institute for Digital Communications, University of Edinburgh, Edinburgh, EH9 3JL, UK
| |
Collapse
|
13
|
Wang G, Wang WL, Liu YQ, Dong HM, Hu YX. Positioning error and expanding margins of planning target volume with kilovoltage cone beam computed tomography for prostate cancer radiotherapy. Onco Targets Ther 2018; 11:1981-1988. [PMID: 29670373 PMCID: PMC5898597 DOI: 10.2147/ott.s152915] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Objective In this study, prostate cancer patients were treated with image-guided radiotherapy (IGRT). The translational positioning errors were discussed to provide the basis for determining margins of the planning target volume (PTV). Methods Thirty prostate cancer patients were treated with radical radiotherapy using the IGRT system. Patients were placed in the supine position and underwent kilovoltage cone beam computed tomography (KVCBCT) scans before radiotherapy. A total of 447 images were acquired. The translational positioning errors were obtained in three linear directions which were X (left-to-right), Y (superior-to-inferior) and Z (anterior-to-posterior) axes (denoted as Lx, Ly and Lz) through the contrast between images adjusted with gray and manual registrations and the planning CT images. Rotational errors were denoted as Rx, Ry and Rz. Results Uncorrected translational errors Lx, Ly and Lz in the 251 positioning images were all higher than those after correction, and the differences were all statistically significant (P=0.000, 0.037 and 0.004, respectively). For rotational errors Rx, Ry and Rz, only Rx had a significant difference before and after correction (P=0.044). Before correction, PTV margins in the X, Y and Z directions were 0.61, 0.78 and 0.41 cm, respectively; after correction, these were 0.17, 0.12 and 0.17 cm, respectively. Conclusion KVCBCT can be applied to measure positioning errors in prostate cancer radiotherapy and correct these errors in real time through the 6° robotic patient positioning system, in order to improve patient positioning accuracy. The application of IGRT with KVCBCT may reduce PTV margins.
Collapse
Affiliation(s)
- Gang Wang
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Wen-Ling Wang
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Yi-Qun Liu
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Hong-Min Dong
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| | - Yin-Xiang Hu
- Department of Abdominal Oncology, Affiliated Hospital of Guizhou Medical University, Guizhou Cancer Hospital, Guiyang, People's Republic of China
| |
Collapse
|
14
|
Imtiaz Ul Haq M, Kim D. Greedy Successive Anchorization for Localizing Machine Type Communication Devices. Sensors (Basel) 2016; 16:s16122115. [PMID: 27983576 PMCID: PMC5191095 DOI: 10.3390/s16122115] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 12/05/2016] [Accepted: 12/07/2016] [Indexed: 11/16/2022]
Abstract
Localization of machine type communication (MTC) devices is essential for various types of location-based applications. In this paper, we investigate a distributed localization problem in noisy networks, where an estimated position of blind MTC machines (BMs) is obtained by using noisy measurements of distance between BM and anchor machines (AMs). We allow positioned BMs also to work as anchors that are referred to as virtual AMs (VAMs) in this paper. VAMs usually have greater position errors than (original) AMs, and, if used as anchors, the error propagates through the whole network. However, VAMs are necessary, especially when many BMs are distributed in a large area with an insufficient number of AMs. To overcome the error propagation, we propose a greedy successive anchorization process (GSAP). A round of GSAP consists of consecutive two steps. In the first step, a greedy selection of anchors among AMs and VAMs is done by which GSAP considers only those three anchors that possibly pertain to the localization accuracy. In the second step, each BM that can select three anchors in its neighbor determines its location with a proposed distributed localization algorithm. Iterative rounds of GSAP terminate when every BM in the network finds its location. To examine the performance of GSAP, a root mean square error (RMSE) metric is used and the corresponding Cramér-Rao lower bound (CRLB) is provided. By numerical investigation, RMSE performance of GSAP is shown to be better than existing localization methods with and without an anchor selection method and mostly close to the CRLB.
Collapse
Affiliation(s)
- Mian Imtiaz Ul Haq
- Department of Electronics and Communication Engineering, Hanyang University, Ansan 15588, Korea.
| | - Dongwoo Kim
- Department of Electronics and Communication Engineering, Hanyang University, Ansan 15588, Korea.
| |
Collapse
|