1
|
Wan D, Xia X, Wang H, He S, Dong J, Dai J, Guan D, Zheng J, Yang X, Zi Y. A Compact-Sized Fully Self-Powered Wireless Flowmeter Based on Triboelectric Discharge. Small Methods 2024:e2301670. [PMID: 38634248 DOI: 10.1002/smtd.202301670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/29/2024] [Indexed: 04/19/2024]
Abstract
Flow sensing exhibits significant potential for monitoring, controlling, and optimizing processes in industries, resource management, and environmental protection. However, achieving wireless real-time and omnidirectional sensing of gas/liquid flow on a simple, self-contained device without external power support has remained a formidable challenge. In this study, a compact-sized, fully self-powered wireless sensing flowmeter (CSWF) is introduced with a small size diameter of down to less than 50 mm, which can transmit real-time and omnidirectional wireless signals, as driven by a rotating triboelectric nanogenerator (R-TENG). The R-TENG triggers the breakdown discharge of a gas discharge tube (GDT), which enables flow rate wireless sensing through emitted electromagnetic waves. Importantly, the performance of the CSWF is not affected by the R-TENG's varied output, while the transmission distance is greater than 10 m. Real-time wireless remote monitoring of wind speed and water flow rate is successfully demonstrated. This research introduces an approach to achieve a wireless, self-powered environmental monitoring system with a diverse range of potential applications, including prolonged meteorological observations, marine environment monitoring, early warning systems for natural disasters, and remote ecosystem monitoring.
Collapse
Affiliation(s)
- Dong Wan
- Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou, Guangdong, 511400, China
| | - Xin Xia
- Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou, Guangdong, 511400, China
| | - Haoyu Wang
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Shaoshuai He
- Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou, Guangdong, 511400, China
| | - Jiadan Dong
- State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan, 430079, China
| | - Jinhong Dai
- Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou, Guangdong, 511400, China
| | - Dong Guan
- College of Mechanical Engineering, Yangzhou University, Yangzhou, Jiangsu, 225127, China
| | - Junyu Zheng
- Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou, Guangdong, 511400, China
| | - Xiya Yang
- Institute of New Energy Technology, College of Information Science and Technology, Jinan University, Guangzhou, 510632, China
| | - Yunlong Zi
- Thrust of Sustainable Energy and Environment, The Hong Kong University of Science and Technology (Guangzhou), Nansha, Guangzhou, Guangdong, 511400, China
- HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute, Futian, Shenzhen, Guangdong, 518048, China
- Guangzhou HKUST Fok Ying Tung Research Institute, Guangzhou, Guangdong, 511400, China
| |
Collapse
|
2
|
Siddiq S, Murray V, Tyagi N, Borman P, Gui C, Crane C, Wu C, Otazo R. MR signature matching (MRSIGMA) implementation for true real-time free-breathing volumetric imaging with sub-200 ms latency on an MR-Linac. Magn Reson Med 2024. [PMID: 38576131 DOI: 10.1002/mrm.30097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 02/20/2024] [Accepted: 03/14/2024] [Indexed: 04/06/2024]
Abstract
PURPOSE Develop a true real-time implementation of MR signature matching (MRSIGMA) for free-breathing 3D MRI with sub-200 ms latency on the Elekta Unity 1.5T MR-Linac. METHODS MRSIGMA was implemented on an external computer with a network connection to the MR-Linac. Stack-of-stars with partial kz sampling was used to accelerate data acquisition and ReconSocket was employed for simultaneous data transmission. Movienet network computed the 4D MRI motion dictionary and correlation analysis was used for signature matching. A programmable 4D MRI phantom was utilized to evaluate MRSIGMA with respect to a ground-truth translational motion reference. In vivo validation was performed on patients with pancreatic cancer, where 15 patients were employed to train Movienet and 7 patients to test the real-time implementation of MRSIGMA. Dice coefficients between real-time MRSIGMA and a retrospectively computed 4D reference were used to evaluate motion tracking performance. RESULTS Motion dictionary was computed in under 5 s. Signature acquisition and matching presented 173 ms latency on the phantom and 193 ms on patients. MRSIGMA presented a mean error of 1.3-1.6 mm for all phantom experiments, which was below the 2 mm acquisition resolution along the motion direction. The Dice coefficient over time between MRSIGMA and reference contours was 0.88 ± 0.02 (GTV), 0.87 ± 0.02(duodenum-stomach), and 0.78 ± 0.02(small bowel), demonstrating high motion tracking performance for both tumor and organs at risk. CONCLUSION The real-time implementation of MRSIGMA enabled true real-time free-breathing 3D MRI with sub-200 ms imaging latency on a clinical MR-Linac system, which can be used for treatment monitoring, adaptive radiotherapy and dose accumulation mapping in tumors affected by respiratory motion.
Collapse
Affiliation(s)
- Saad Siddiq
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Victor Murray
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Neelam Tyagi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Pim Borman
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Chengcheng Gui
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Christopher Crane
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Can Wu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
3
|
Wagner MG, Kutlu AZ, Davis B, Raval AN, Laeseke PF, Speidel MA. Topology observing 3D device reconstruction from continuous-sweep limited angle fluoroscopy. Med Phys 2024; 51:2882-2892. [PMID: 38308822 DOI: 10.1002/mp.16954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 12/20/2023] [Accepted: 01/12/2024] [Indexed: 02/05/2024] Open
Abstract
BACKGROUND Minimally invasive procedures usually require navigating a microcatheter and guidewire through endoluminal structures such as blood vessels and airways to sites of the disease. For numerous clinical applications, two-dimensional (2D) fluoroscopy is the primary modality used for real-time image guidance during navigation. However, 2D imaging can pose challenges for navigation in complex structures. Real-time 3D visualization of devices within the anatomic context could provide considerable benefits for these procedures. Continuous-sweep limited angle (CLA) fluoroscopy has recently been proposed to provide a compromise between conventional rotational 3D acquisitions and real-time fluoroscopy. PURPOSE The purpose of this work was to develop and evaluate a noniterative 3D device reconstruction approach for CLA fluoroscopy acquisitions, which takes into account endoluminal topology to avoid impossible paths between disconnected branches. METHODS The algorithm relies on a static 3D roadmap (RM) of vessels or airways, which may be generated from conventional cone beam CT (CBCT) acquisitions prior to navigation. The RM is converted to a graph representation describing its topology. During catheter navigation, the device is segmented from the live 2D projection images using a deep learning approach from which the centerlines are extracted. Rays from the focal spot to detector pixels representing 2D device points are identified and intersections with the RM are computed. Based on the RM graph, a subset of line segments is selected as candidates to exclude device paths through disconnected branches of the RM. Depth localization for each point along the device is then performed by finding the point closest to the previous 3D reconstruction along the candidate segments. This process is repeated as the projection angle changes for each CLA image frame. The approach was evaluated in a phantom study in which a catheter and guidewire were navigated along five pathways within a complex vessel phantom. The result was compared to static cCBCT acquisitions of the device in the final position. RESULTS The average root mean squared 3D distance between CLA reconstruction and reference centerline was1.87 ± 0.30 $1.87 \pm 0.30$ mm. The Euclidean distance at the device tip was2.92 ± 2.35 $2.92 \pm 2.35$ mm. The correct pathway was identified during reconstruction in100 % $100\%$ of frames (n = 1475 $n=1475$ ). The percentage of 3D device points reconstructed inside the 3D roadmap was91.83 ± 2.52 % $91.83 \pm 2.52\%$ with an average distance of0.62 ± 0.30 $0.62 \pm 0.30$ mm between the device points outside the roadmap and the nearest point within the roadmap. CONCLUSIONS This study demonstrates the feasibility of reconstructing curvilinear devices such as catheters and guidewires during endoluminal procedures including intravascular and transbronchial interventions using a noniterative reconstruction approach for CLA fluoroscopy. This approach could improve device navigation in cases where the structure of vessels or airways is complex and includes overlapping branches.
Collapse
Affiliation(s)
- Martin G Wagner
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Ayca Z Kutlu
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Brian Davis
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
| | - Amish N Raval
- Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA
| | - Paul F Laeseke
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA
| | - Michael A Speidel
- Department of Medical Physics, University of Wisconsin, Madison, Wisconsin, USA
- Department of Medicine, University of Wisconsin, Madison, Wisconsin, USA
| |
Collapse
|
4
|
Li B, Liu Y, Li G, Zhang Z, Feng Y, Mao B. A real-time patient-specific treatment strategy for enhanced external counterpulsation. Int J Numer Method Biomed Eng 2024; 40:e3808. [PMID: 38409940 DOI: 10.1002/cnm.3808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 01/23/2024] [Accepted: 02/11/2024] [Indexed: 02/28/2024]
Abstract
Diastolic/systolic blood pressure ratio (D/S) ≥ 1.2 is the gold standard of enhanced external counterpulsation (EECP) treatment, but it does not show a clear clinical correspondence with the configuration of the EECP mode. As such, a single target results in different treatment effects in different individuals. The local haemodynamic effect (wall shear stress, WSS) of EECP on vascular endothelial cells is conducive to promote the growth of collateral circulation vessels and restore the blood supply distal to the stenosis lesion. Considering the haemodynamic effects of WSS on human arteries, this study developed a real-time patient-specific treatment strategy of EECP for patients with cardio-cerebrovascular diseases. Based on patient-specific haemodynamic data from 113 individuals, an optimization algorithm was developed to achieve the individualization of a 0D lumped-parameter model of the human circulatory system, thereby simulating the patient-specific global haemodynamic effects. 0D/3D coupled cardio-cerebrovascular models of two subjects were established to simulate the local WSS. We then established statistical models to evaluate clinically unmeasurable WSS based on measurable global haemodynamic indicators. With the aim of attaining appropriate area- and time-averaged WSS (ATAWSS, 4-7 Pa), as evaluated by global haemodynamic indicators, a closed-loop feedback tuning method was developed to provide patient-specific EECP treatment strategies. Results showed that for clinical data collected from 113 individuals, the individualized 0D model can accurately simulate patient-specific global haemodynamic effects (average error <5%). Based on two subjects, the statistical models can be used to evaluate local ATAWSS (error <6%) for coronary arteries and for cerebral arteries. An EECP mode planned by the patient-specific treatment strategy can promote an appropriate ATAWSS within a 16 s calculation time. The real-time patient-specific treatment strategy of EECP is expected to improve the long-term outcome for each patient and have potential clinical significance.
Collapse
Affiliation(s)
- Bao Li
- Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
| | - Youjun Liu
- Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
| | - Guangfei Li
- Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China
| | - Zhe Zhang
- Department of Cardiac Surgery, Peking University Third Hospital, Beijing, China
| | - Yue Feng
- Medical Equipment Department, Peking University First Hospital, Beijing, China
| | - Boyan Mao
- Department of Biological Engineering, School of Life Sciences, Beijing University of Chinese Medicine, Beijing, China
| |
Collapse
|
5
|
Posse S, Binkofski F, Schneider F, Gembris D, Frings W, Habel U, Salloum JB, Mathiak K, Wiese S, Kiselev V, Graf T, Elghahwagi B, Grosse-Ruyken ML, Eickermann T. A new approach to measure single-event related brain activity using real-time fMRI: feasibility of sensory, motor, and higher cognitive tasks. Hum Brain Mapp 2000; 12:25-41. [PMID: 11198103 PMCID: PMC6871962 DOI: 10.1002/1097-0193(200101)12:1<25::aid-hbm30>3.0.co;2-h] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Real-time fMRI is a rapidly emerging methodology that enables monitoring changes in brain activity during an ongoing experiment. In this article we demonstrate the feasibility of performing single-event sensory, motor, and higher cognitive tasks in real-time on a clinical whole-body scanner. This approach requires sensitivity optimized fMRI methods: Using statistical parametric mapping we quantified the spatial extent of BOLD contrast signal changes as a function of voxel size and demonstrate that sacrificing spatial resolution and readout bandwidth improves the detection of signal changes in real time. Further increases in BOLD contrast sensitivity were obtained by using real-time multi-echo EPI. Real-time image analysis was performed using our previously described Functional Imaging in REal time (FIRE) software package, which features real-time motion compensation, sliding window correlation analysis, and automatic reference vector optimization. This new fMRI methodology was validated using single-block design paradigms of standard visual, motor, and auditory tasks. Further, we demonstrate the sensitivity of this method for online detection of higher cognitive functions during a language task using single-block design paradigms. Finally, we used single-event fMRI to characterize the variability of the hemodynamic impulse response in primary and supplementary motor cortex in consecutive trials using single movements. Real-time fMRI can improve reliability of clinical and research studies and offers new opportunities for studying higher cognitive functions.
Collapse
Affiliation(s)
- S Posse
- Institute of Medicine, Research Center Jülich GmbH, Germany.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|