1
|
Tarantini G, Cardaioli F, De Iaco G, Tuccillo B, De Angelis MC, Mauro C, Boccalatte M, Trivisonno A, Ribichini F, Vadalà G, Caramanno G, Caruso M, Lombardi M, Fischetti D, Danesi A, Abbracciavento L, Lorenzoni G, Gregori D, Panza A, Nai Fovino L, Esposito G. A more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: an Italian post-maRketing study (the CAESAR registry). Front Cardiovasc Med 2024; 10:1326091. [PMID: 38299080 PMCID: PMC10828965 DOI: 10.3389/fcvm.2023.1326091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 12/11/2023] [Indexed: 02/02/2024] Open
Abstract
Introduction The use of contemporary drug-eluting stents (DES) has significantly improved outcomes of patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, concerns exist regarding the long-term proinflammatory effects of durable polymer coatings used in most DES, potentially leading to long-term adverse events. First-generation polymer-free stent technologies, such as sirolimus- and probucol-eluting stents (PF-SES), have shown an excellent safety and efficacy profile. The aim of this study was to evaluate the safety and efficacy of the new ultrathin Coroflex ISAR NEO PF-SES, in a more-comers PCI population. Methods The CAESAR (a more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: An Italian post-maRketing study) registry is a multicenter, prospective study conducted in Italy, enrolling more-comers CAD patients undergoing PCI with the Coroflex ISAR NEO stent. Patients with left main (LM) disease, cardiogenic shock (CS), or severely reduced left-ventricular ejection fraction (LVEF) were excluded. The primary endpoint was target-lesion revascularization (TLR) at 1 year. Results A total of 425 patients were enrolled at 13 centers (mean age 66.9 ± 11.6 years, Diabetes mellitus 29%, acute coronary syndrome 67%, chronic total occlusion 9%). Of these, 40.9% had multivessel disease (MVD) and in 3.3% cases, the target lesion was in-stent restenosis (ISR). Clinical device success was reached in 422 (99.6%) cases. At 1 year, only two (0.5%) subjects presented ischemia-driven TLR. The 1-year rates of target vessel revascularization and MACE were 0.5% and 5.1%, respectively. Major bleeding was observed in four (1.0%) patients. Conclusion In this multicenter, prospective registry, the use of a new ultrathin Coroflex ISAR NEO PF-SES in a more-comers PCI population showed good safety and efficacy at 1 year.
Collapse
Affiliation(s)
- Giuseppe Tarantini
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padova, Italy
| | - Francesco Cardaioli
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padova, Italy
| | - Giuseppe De Iaco
- Department of Cardiology, Hospital “Cardinal G. Panico”, Tricase, Italy
| | | | | | - Ciro Mauro
- Department of Cardiology, Hospital Cardarelli, Naples, Italy
| | - Marco Boccalatte
- Interventional Cardiology Unit, Ospedale Santa Maria Delle Grazie Pozzuoli, Napoli, Italy
| | - Antonio Trivisonno
- Department of Cardiovascular Disease, “Antonio Cardarelli” Hospital, Campobasso, Italy
| | | | - Giuseppe Vadalà
- Division of Cardiology, University Hospital Paolo Giaccone, Palermo, Italy
| | - Giuseppe Caramanno
- Interventional Cardiology, San Giovanni di Dio Hospital, Agrigento, Italy
| | - Marco Caruso
- Interventional Cardiology Unit, ARNAS Civico, G. Di Cristina Benfratelli, Palermo, Italy
| | - Mario Lombardi
- Interventional Cardiology Unit, A.O. Riuniti Villa Sofia-Cervello, Palermo, Italy
| | | | | | | | - Giulia Lorenzoni
- Unit of Biostatistics, Epidemiology and Public Health, University of Padova, Padova, Italy
| | - Dario Gregori
- Unit of Biostatistics, Epidemiology and Public Health, University of Padova, Padova, Italy
| | - Andrea Panza
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padova, Italy
| | - Luca Nai Fovino
- Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padova, Italy
| | - Giovanni Esposito
- Division of Cardiology, Università Degli Studi di Napoli Federico II, Napoli, Italy
| |
Collapse
|
2
|
Grundeken MJ, Beijk MAM. A Narrative Review of Ultrathin-strut Drug-eluting Stents: The Thinner the Better? Heart Int 2021; 15:84-93. [PMID: 36277831 PMCID: PMC9524587 DOI: 10.17925/hi.2021.15.2.84] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Accepted: 10/15/2021] [Indexed: 08/05/2023] Open
Abstract
Second-generation drug-eluting stents (DES) are considered standard of care for revascularization of patients undergoing percutaneous coronary intervention. Besides the polymer and antiproliferative drug used, the metallic backbone of DES is an attractive target for further development. Ultrathin-strut DES (≤70 μm strut thickness) are more flexible, have an improved trackability and crossability compared to conventional second-generation DES. Importantly, ultrathin-strut DES reduce the risk of in-stent restenosis, thereby decreasing the risk of angiographic and clinical restenosis. In this narrative review, we will discuss the clinical outcomes of the commercially available ultrathin-strut DES.
Collapse
Affiliation(s)
- Maik J Grundeken
- Department of Cardiology, Amsterdam University Medical Centre – location AMC, Amsterdam, The Netherlands
| | - Marcel AM Beijk
- Department of Cardiology, Amsterdam University Medical Centre – location AMC, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Milewski K, Gąsior P, Samborski S, Buszman PP, Błachut A, Wojtaszczyk A, Młodziankowski A, Mendyk A, Król M, Wojakowski W, Buszman PE. Evaluation of safety and efficacy of NexGen - an ultrathin strut and hybrid cell design cobalt-chromium bare metal stent implanted in a real life patient population - the Polish NexGen Registry. Postepy Kardiol Interwencyjnej 2016; 12:217-23. [PMID: 27625684 DOI: 10.5114/aic.2016.61642] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Accepted: 03/01/2016] [Indexed: 01/15/2023] Open
Abstract
INTRODUCTION Despite the dominance of drug-eluting stents in modern interventional cardiology, there is still a niche for bare metal stents. AIM The aim of the Polish NexGen registry was to evaluate the safety and efficacy of a new generation cobalt-chromium NexGen stent in a real life patient population. MATERIAL AND METHODS A prospective multi-center registry was conducted in five clinical sites of American Heart of Poland. Three hundred and eighty-three patients who underwent percutaneous coronary intervention (PCI) with NexGen stent implantation were included. Clinical follow-up was performed at 1, 6 and 12 months. Additionally, a group of 42 randomly selected patients underwent control angiography at 6 months (10.96% of study population). The primary endpoint was occurrence of target vessel revascularization (TVR) at 6-month follow-up. Angiographic endpoints included rates of binary restenosis and late lumen loss at 6-month follow-up based on QCA analysis. Multivessel disease was present in more than 70% of patients, and 52.4% of lesions were complex. The main indications for angiography were non-ST elevation acute coronary syndromes (54.8%) and ST elevation myocardial infarction (34.99%). RESULTS At 6-month follow-up 47 (12.7%) patients reached the primary endpoint of TVR. The composite of major acute cardiac event rates at 30-day and 6- and 12-month follow-up was 6.01% (n = 23), 18.5% (n = 69) and 25.21% (n = 92) respectively. Control angiography performed after 6 months showed in-stent late loss of 0.66 ±0.71 mm and a binary restenosis rate of 16.7%. CONCLUSIONS Our study showed that PCI with the NexGen stent is safe and effective at 6- and 12-month follow-up. Angiographic results showed a satisfactory restenosis rate and low late lumen loss.
Collapse
|