1
|
Ho KJ, Devlin PM, Madenci AL, Semel ME, Gravereaux EC, Nguyen LL, Belkin M, Menard MT. High dose-rate brachytherapy for the treatment of lower extremity in-stent restenosis. J Vasc Surg 2016; 65:734-743. [PMID: 27986482 DOI: 10.1016/j.jvs.2016.10.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Accepted: 10/03/2016] [Indexed: 11/19/2022]
Abstract
OBJECTIVE Historically, edge stenosis and late thrombosis limited the effectiveness of adjunctive endovascular brachytherapy (EVBT) for in-stent restenosis (ISR) after percutaneous transluminal angioplasty (PTA) and stenting. We evaluated an updated protocol of PTA and EVBT for ISR among patients with lower extremity occlusive disease. METHODS This is a retrospective, single-center review of patients treated with PTA and EVBT for ISR in the iliac and femoropopliteal segments between 2004 and 2012. A dose of 20 Gy was given at a depth of 0.5 mm beyond the radius of the largest PTA balloon using iridium 192, with at least 2-cm-long margins of radiation coverage proximal and distal to the injured area. Stents were assessed for patency by duplex ultrasound imaging at 1, 3, 6, 9, 12, and 18 months and then yearly. The primary end point was freedom from ≥50% restenosis in the treated segment at 6 months, 1 year, and 2 years. Patency data were estimated using the Kaplan-Meier method. Secondary end points were early and late thrombotic occlusion. RESULTS Among 42 consecutive cases in 35 patients of EVBT for ISR in common or external iliac (9 [20.8%]) and superficial femoral or popliteal (33 [76.7%]) arteries, or both, 21 patients (50%) had claudication, asymptomatic hemodynamically significant stenoses were identified on duplex ultrasound imaging in 16 (38.1%), and 4 (9.8%) had critical limb ischemia. Mean treated length was 23.5 ± 12.3 cm over a mean duration of 16.1 ± 9.6 minutes. There was one technical failure (2.3%). Median post-EVBT follow-up time was 682 days (range, 1-2262 days). There were two (4.9%) and five (11.9%) cases of early and late thrombotic occlusions, respectively. There was one death, believed to be secondary to acute coronary syndrome. Primary, assisted primary, and secondary patency in the entire cohort was 75.2%, 89.1%, and 89.1%, respectively, at 1 year and 63.7%, 80.6%, and 85.6%, respectively, at 2 years. CONCLUSIONS This contemporary protocol of PTA and adjunctive EVBT for lower extremity ISR, which is updated from those used in prior trials and includes a surveillance strategy that identifies at-risk stents for reintervention before occlusion, may be a promising treatment for lower extremity ISR at institutions where a close collaboration between vascular surgeons and radiation oncologists is feasible.
Collapse
Affiliation(s)
- Karen J Ho
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, Ill
| | - Phillip M Devlin
- Department of Radiation Oncology, Brigham and Women's Hospital, Boston, Mass
| | - Arin L Madenci
- Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Boston, Mass
| | - Marcus E Semel
- Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Boston, Mass
| | - Edwin C Gravereaux
- Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Boston, Mass
| | - Louis L Nguyen
- Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Boston, Mass
| | - Michael Belkin
- Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Boston, Mass
| | - Matthew T Menard
- Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Boston, Mass.
| |
Collapse
|
2
|
Russo G, Rotondo M, Punzo A, Di Napoli D. Excimer Laser Assisted Non-occlusive Anastomosis (ELANA). Our experience with a training model in vivo. J Neurosurg Sci 2007; 51:11-6. [PMID: 17369786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
AIM In this study the ELANA Technique has been reproduced in our experimental laboratory in order to verify its feasibility and reproducibility, the percentage of patent anastomosis in acute at different steps along the learning curve of the surgical team, specific problems related to the surgical technique. METHODS In 20 rabbits New Zealand 4kg body weight the training model in vivo proposed by Tulleken and coworkers has been reproduced, realizing 40 ELANA anastomosis. The model consists in the realization of two different end-to-side anastomosis on the abdominal aorta of each experimental animal, assisted by a special designed suction/excimer laser catheter, then connected by an end-to-end suture. After a few hours the animals are sacrificed and the by-pass site withdrawn and examined in order to verify the percentage of patency in acute. RESULTS In the first 5 animals (group A), the anastomosis were realized using a jugular vein graft and the procedure results successful in only 3 cases out of ten (30%). For the following experiments - groups B, C and D where an aorta artery graft was used, the percentage of arterial flap retrieval was respectively 50%, 60% and 80%. CONCLUSIONS ELANA is a feasible fascinating microsurgical technique for the realization of high flow, non-occlusive anastomosis. The rate of success results progressively higher along the learning curve of the surgical team. In our opinion, before the application of the ELANA technique on humans, a period of propaedeutic training in vivo on laboratory animals is essential for the dedicated team.
Collapse
Affiliation(s)
- G Russo
- Unit of Neurosurgery, AORN A. Cardarelli, Naples, Italy. giuseppe.russo@ospesdale/cardarelli.it
| | | | | | | |
Collapse
|
3
|
Lin CC, Chang CF, Lai MY, Chen TW, Lee PC, Yang WC. Far-infrared therapy: a novel treatment to improve access blood flow and unassisted patency of arteriovenous fistula in hemodialysis patients. J Am Soc Nephrol 2007; 18:985-92. [PMID: 17267744 DOI: 10.1681/asn.2006050534] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
Vascular access malfunction, usually presenting with an inadequate access flow (Qa), is the leading cause of morbidity and hospitalization in hemodialysis (HD) patients. Many methods of thermal therapy have been tried for improving Qa but with limited effects. This randomized trial was designed to evaluate the effect of far-infrared (FIR) therapy on access flow and patency of the native arteriovenous fistula (AVF). A total of 145 HD patients were enrolled with 73 in the control group and 72 in the FIR group. A WS TY101 FIR emitter was used for 40 min, and hemodynamic parameters were measured by the Transonic HD(02) monitor during HD. The Qa(1)/Qa(2) and Qa(3)/Qa(4) were defined as the Qa measured at the beginning/at 40 min later in the HD session before the initiation and at the end of the study, respectively. The incremental change of Qa in the single HD session with FIR therapy was significantly higher than that without FIR therapy (13.2 +/- 114.7 versus -33.4 +/- 132.3 ml/min; P = 0.021). In comparison with control subjects, patients who received FIR therapy for 1 yr had (1) a lower incidence (12.5 versus 30.1%; P < 0.01) and relative incidence (one episode per 67.7 versus one episode per 26.7 patient-months; P = 0.03) of AVF malfunction; (2) higher values of the following parameters, including Delta(Qa(4) - Qa(3)) (36.2 +/- 82.4 versus -12.7 +/- 153.6 ml/min; P = 0.027), Delta(Qa(3) - Qa(1)) (36.3 +/- 166.2 versus -51.7 +/- 283.1 ml/min; P = 0.035), Delta(Qa(4) - Qa(2)) (99.2 +/- 144.4 versus -47.5 +/- 244.5 ml/min; P < 0.001), and Delta(Qa(4) - Qa(2)) - Delta(Qa(3) - Qa(1)) (62.9 +/- 111.6 versus 4.1 +/- 184.5 ml/min; P = 0.032); and (3) a better unassisted patency of AVF (85.9 versus 67.6%; P < 0.01). In conclusion, FIR therapy, a noninvasive and convenient therapeutic modality, can improve Qa and survival of the AVF in HD patients through both its thermal and its nonthermal effects.
Collapse
Affiliation(s)
- Chih-Ching Lin
- Division of Nephrology, Institute of Clinical Medicine and School of Medicine, National Yang-Ming University, Taipei, Taiwan, Republic of China
| | | | | | | | | | | |
Collapse
|
4
|
Haywood LJ. Acute myocardial infarction with normal coronary arteries in a patient with Hodgkin's disease. Tex Heart Inst J 2007; 34:135. [PMID: 17420816 PMCID: PMC1847911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
|
5
|
Ribichini F, Ferrero V, Piessens M, Heyndrickx GR, de Bruyne B, Verbeke L, Matullo G, Büchi M, Piazza A, Guarrera S, Lüscher TF, Wijns W. Intracoronary β-irradiation prevents excessive in-stent neointimal proliferation in de novo lesions of patients with high plasma ACE levels. The BetAce randomized trial. Cardiovascular Revascularization Medicine 2005; 6:7-13. [PMID: 16263350 DOI: 10.1016/j.carrev.2005.02.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2005] [Accepted: 02/22/2005] [Indexed: 10/25/2022]
Abstract
BACKGROUND This study evaluated vascular brachytherapy (VBT) as a potent antiproliferative treatment to prevent in-stent restenosis (ISR) after coronary angioplasty of de novo lesions in patients carrying the D allele of the I/D polymorphism of the ACE gene and high ACE plasma levels (>34 U/l). METHODS AND MATERIALS A prospective randomized trial was designed to detect a 30% improvement in the minimal lumen diameter (MLD) of the stenotic artery, as measured by quantitative coronary analysis (QCA), 6 months following VBT at the time of stented angioplasty. All patients were carriers of the D allele of the ACE gene, with plasma ACE levels >34 U/l. RESULTS Thirty-one patients (33 stenoses) were allocated to stent implantation (control group) and 30 patients (31 stenoses) to VBT and stented angioplasty. After angioplasty, in-stent MLD was similar in the two groups. At 6 months in the control group, in-stent MLD had decreased to 1.74+/-0.8 versus 2.25+/-1.05 mm in the VBT group (P=.04). The mean in-stent diameter was 2.3+/-0.8 mm in the control group versus 2.9+/-1.05 mm after VBT (P=.02), and the restenosis rate was 37.5% versus 17.9%, respectively (P=.08). At 6 months, a higher need for target vessel revascularization (TVR) was observed in the control group: 35.5% versus 13.3% (P=.04). CONCLUSIONS This randomized study confirms that patients with high plasma ACE concentrations are exposed to an increased risk for ISR after coronary stenting. The preventive use of VBT in these patients reduced neointimal formation by 65% such that the MLD at follow-up was increased by 29% compared with the control group.
Collapse
Affiliation(s)
- Flavio Ribichini
- Division of Cardiology, Università del Piemonte Orientale, Ospedale Maggiore della Carita', Novara, Italy.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Abstract
OBJECTIVE Extracranial carotid stenosis is a complication of external head and neck irradiation. The safety and durability of carotid artery revascularization through a radiated field has been debated. We describe the immediate and long-term results in a series of 27 consecutive patients who received treatment over 12 years. METHODS From May 1990 to May 2002, 27 consecutive patients underwent 30 primary carotid artery revascularization procedures. All patients had received previous radiation therapy within a mean interval of 10 years (range, 1-26 years), with average radiation dose of 62 Gy (range, 50-70 Gy). Moderate to severe scarring of the skin or radiation fibrosis was present in three fourths of patients. Thirteen patients (48%) had undergone radical neck dissection, and 2 patients had a permanent tracheotomy. The indications for carotid surgery included high-grade (>70%) symptomatic stenosis in 18 patients (60%) and high-grade asymptomatic stenosis in 12 patients (40%). General anesthesia with systematic shunting was used in 18 patients (60%), and regional anesthesia with selective shunting was used in 12 patients (40%). Operations included standard carotid endarterectomy (n = 20), with patch angioplasty (n = 12) or direct closure (n = 8); carotid interposition bypass grafting (n = 7); and subclavian to carotid bypass grafting (n = 3). Primary closure of the surgical wound was performed in all procedures without any special muscular or skin flaps. All patients were followed up for a mean of 40 months (range, 3-99 months). RESULTS There was one (3.3%) perioperative death, from massive intracerebral hemorrhage; and 1 patient had a transient ischemic attack. In-hospital complications included neck hematoma in 2 patients, which required surgical drainage in 1 patient. There was neither delayed wound healing nor infection. Twelve patients died during follow-up, of causes not related to treatment. None of the surviving patients had further stroke, and all remained asymptomatic. Follow-up duplex scans showed asymptomatic recurrent stenosis greater than 60% in 3 patients, 2 of whom with stenosis greater than 80% underwent repeat operation. Risk for recurrent stenosis greater than 60% at 18 months was 16.6%. Recurrent stenosis occurred in 2 of these patients after saphenous vein bypass, and in 1 patient after endarterectomy with vein patch angioplasty. CONCLUSION The clinical results and sustained freedom from symptoms and stroke over 40-month follow-up suggests that carotid revascularization through a radiated field is a safe and durable procedure in patients at high surgical risk, despite a marked incidence of recurrent stenosis.
Collapse
Affiliation(s)
- Guy Lesèche
- Service de Chirurgie Vasculaire et Thoracique, Hôpital Beaujon, Assistance Publique des Hôpitaux de Paris, 100 Boulevard du Général Leclerc, 92110 Clichy, France.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Popma JJ, Suntharalingam M, Lansky AJ, Heuser RR, Speiser B, Teirstein PS, Massullo V, Bass T, Henderson R, Silber S, von Rottkay P, Bonan R, Ho KKL, Osattin A, Kuntz RE. Randomized trial of 90Sr/90Y beta-radiation versus placebo control for treatment of in-stent restenosis. Circulation 2002; 106:1090-6. [PMID: 12196334 DOI: 10.1161/01.cir.0000027814.96651.72] [Citation(s) in RCA: 163] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND After conventional treatment of in-stent restenosis, the incidence of recurrent clinical restenosis may approach 40%. We report the first multicenter, blinded, and randomized trial of intracoronary radiation with the use of a 90Sr/90Y beta-source for the treatment of in-stent restenosis. METHODS AND RESULTS After successful catheter-based treatment of in-stent restenosis, 476 patients were randomly assigned to receive an intracoronary catheter containing either 90Sr/90Y (n=244) or placebo (n=232) sources. The prescribed dose 2 mm from the center of the source was 18.4 Gy for vessels between 2.70 and 3.35 mm in diameter and 23.0 Gy for vessels between 3.36 and 4.0 mm. The primary end point, ie, clinically driven target-vessel revascularization by 8 months, was observed in 56 (26.8%) of the patients assigned to placebo and 39 (17.0%) of the patients assigned to radiation (P=0.015). The incidence of the composite including death, myocardial infarction, and target-vessel revascularization was observed in 60 (28.7%) of the patients assigned to placebo and 44 (19.1%) of the patients assigned to radiation (P=0.024). Binary 8-month angiographic restenosis (> or =50% diameter stenosis) within the entire segment treated with radiation was reduced from 45.2% in the placebo-treated patients to 28.8% in the 90Sr/90Y-treated patients (P=0.001). Stent thromboses occurred in 1 patient assigned to placebo <24 hours after the procedure and in 1 patient assigned to 90Sr/90Y at day 244. CONCLUSIONS The results of this study demonstrated that beta-radiation using 90Sr/90Y is both safe and effective for preventing recurrence in patients with in-stent restenosis.
Collapse
Affiliation(s)
- Jeffrey J Popma
- Interventional Cardiology, Brigham and Women's Hospital, Boston, Mass 02115, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Meerkin D, Joyal M, Tardif JC, Lespérance J, Arsenault A, Lucier G, Bonan R. Two-year angiographic follow-up of intracoronary Sr90 therapy for restenosis prevention after balloon angioplasty. Circulation 2002; 106:539-43. [PMID: 12147533 DOI: 10.1161/01.cir.0000023897.49599.6a] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Postcoronary angioplasty vascular brachytherapy (VBT) has emerged as a successful intervention for restenosis prevention in some clinical scenarios. Longer-term follow-up after VBT in de novo nonstented lesions has not been reported. METHODS AND RESULTS Thirty patients treated with post-percutaneous transluminal coronary angioplasty (PTCA) VBT with Sr90 underwent clinical and angiographic follow-up at 6 and 24 months. Specific vessel segment quantitative coronary angiographic analyses were performed to identify radiation edge effects. Nineteen patients who had not undergone index procedure stenting or target vessel revascularization (TVR) over the 2-year period were analyzed separately. Of the 30 patients, 3 underwent TVR by 6-month follow-up. An additional 4 patients required TVR between 6 and 24 months. In the total cohort of 26 patients undergoing angiographic follow-up at 6 and 24 months, an increase in minimal lumen diameter of the initial target segment was noted at 6 months compared with postprocedure analysis (2.31+/-0.48 versus 2.04+/-0.43 mm, P<0.05). At 24 months, this was no longer significant (2.19+/-0.61 mm). In the proximal segments of the entire cohort and the nonintervened subgroup, the principal late loss occurred over the first 6 months with no additional late loss at 2-year follow-up. The distal segments remained stable over the entire follow-up period. CONCLUSIONS Although some late failures of post-PTCA VBT are seen between 6 and 24 months, most treated vessels remain stable with no late loss or additional luminal increase beyond the 6-month period. This suggests that late aneurysm formation and significant late edge restenosis are unlikely in VBT after PTCA of de novo lesions for up to 2 years.
Collapse
|
9
|
Burgher JM, Barton JM, Farooq MM, Vasek J, Scott RW, Freischlag JA, Grove RI. PhotoPoint photodynamic therapy with local drug delivery eliminates vessel wall cells in arteriovenous graft models. Cardiovasc Radiat Med 2002; 3:163-8. [PMID: 12974367 DOI: 10.1016/s1522-1865(03)00080-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE To demonstrate the feasibility of PhotoPoint photodynamic therapy (PDT) with local drug delivery, optimize dosimetry in a rabbit jugular vein model, and investigate its ability to deplete potential neointimal precursor cells in the vessel wall in a canine arteriovenous graft (AVG) model. METHODS AND MATERIALS Photosensitizer MV2101 was administered locally in rabbit veins, incubated for 0-40 min and activated with external laser light. In canine veins, MV2101 was incubated for 30 min and activated by light. Tissues were excised at acute and chronic timepoints. RESULTS PhotoPoint PDT reduced cell populations in both models with maximum depletions occurring at 20 min (> or = 100 J/cm2) in rabbit veins (> 90% depletion) and 30 min (200 J/cm2) in canine veins (> 85% depletion). Chronic veins revealed no evidence of PhotoPoint PDT-related abnormalities. CONCLUSIONS PhotoPoint PDT with local MV2101 dramatically depleted potential neointimal precursor cells in the vessel wall. This suggests local drug delivery is feasible and that PhotoPoint PDT may be an efficacious treatment that could prolong AVG patency in the clinic.
Collapse
Affiliation(s)
- Julie M Burgher
- Miravant Medical Technologies, 336 Bollay Drive, Santa Barbara, CA 93117-5550, USA
| | | | | | | | | | | | | |
Collapse
|
10
|
Morino Y, Limpijankit T, Honda Y, Lansky AJ, Waksman R, Bonneau HN, Yock PG, Mintz GS, Fitzgerald PJ. Late vascular response to repeat stenting for in-stent restenosis with and without radiation: an intravascular ultrasound volumetric analysis. Circulation 2002; 105:2465-8. [PMID: 12034650 DOI: 10.1161/01.cir.0000018949.39445.40] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Re-stenting of in-stent restenosis (ISR) improves acute angiographic results. Methods and Results- Volumetric intravascular ultrasound analysis was performed in 70 ISR lesions that received either placebo (n=36) or (192)Ir radiation (n=34). ISR lesions treated by re-stenting were divided into 3 groups: old stent not re-stented (A), old/new stent overlap (B), and new stent only (C). ISR lesions treated without re-stenting were categorized as D. In placebo patients, postintervention lumen volume index (LVI) was significantly greater in re-stented segments B and C than in non-re-stented segment A (P<0.05).At follow-up, however, LVI was similar in all 4 segments secondary to the increased intimal hyperplasia (IH) reaccumulation within the re-stented segments. In patients treated with (192)Ir radiation, LVI was maintained from baseline to follow-up only in non-re-stented segments A and D. Conversely, there was a significant decrease in LVI in re-stented segments B and C (P<0.05). Qualitatively, 79% of patients in the irradiated group had stent struts with undetectable neointimal versus only 27% in the placebo group (P<0.001). Coefficient of variation of IH reaccumulation was greater in re-stented segments of (192)Ir patients (B=57.3% and C=58.9%) than in re-stented segments in placebo patients (B=27.3% and C 26.8%) and non-re-stented segments in irradiated patients. CONCLUSIONS Additional lumen gain from re-stenting ISR lesions is counteracted by exaggerated neointimal proliferation in placebo patients. Maximum effectiveness and safety of radiation can be achieved for ISR lesions when treated without re-stenting. Thus, regardless of supplementary intravascular brachytherapy, repeat stenting strategies provided little long-term advantage.
Collapse
Affiliation(s)
- Yoshihiro Morino
- Center for Research in Cardiovascular Interventions, Stanford University Medical Center, Stanford, CA, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Abstract
Ongoing advances in peripheral endovascular technology have been met with disappointing results because of restenosis within the treated vessel. In particular, stent balloon angioplasty of peripheral vessels has yet to achieve patency rates that approximate conventional treatment in the long term. Recent advances in stent, balloon, and wire construction include the incorporation of radioactive substances in an attempt to ameliorate the inflammatory response provoked by typical endovascular manipulation, a technique termed vascular brachytherapy. gamma- and beta-isotopes and external beam radiation target the very cell population whose activity results in the development of neointimal hyperplasia. Although most clinical research examining the efficacy of vascular brachytherapy has emerged from the coronary artery literature, the use of vascular brachytherapy also has been examined in the peripheral arterial tree and has shown promising results. Current data indicate that vascular brachytherapy is a safe and accessible adjunctive endovascular maneuver that may improve the short-term patency rate of peripheral endovascular applications. The effects on long-term patency rates remain indeterminate compared to conventional therapy.
Collapse
Affiliation(s)
- Anton N Sidawy
- Veterans Affairs Medical Center, 50 Irving Street NW (112), Washington, DC 20422.
| | | | | |
Collapse
|
12
|
Ajani AE, Waksman R, Zimarino M, Kim HS, Pichard AD, Satler LF, Kent KM, White RL, Pinnow E, Mehran R, Lansky A, Lindsay J. Device selection in the treatment of in-stent restenosis with and without radiation (from the Gamma Radiation Trials). Am J Cardiol 2002; 89:137-44. [PMID: 11792331 DOI: 10.1016/s0002-9149(01)02189-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
In-stent restenosis (ISR) is a major limitation of coronary stenting and is associated with high recurrence rates after intervention with all available devices. Intracoronary gamma (gamma) radiation was proved to reduce the recurrence rate after conventional therapy. The purpose of this study was to compare the different devices utilized for the treatment of ISR with and without gamma radiation. To search for the optimal device for the treatment of ISR, 685 patients from the radiation trials for ISR who were randomized to either iridium-192 gamma radiation (559 patients) or placebo (126 patients) following intervention were evaluated. Devices used included balloon percutaneous transluminal coronary angioplasty, excimer laser coronary angioplasty (ELCA), rotational atherectomy, and additional stent implantation. Baseline clinical and angiographic characteristics were similar between the gamma radiation and placebo groups. One- and 6-month clinical and angiographic outcomes were compared. The use of stenting compared with other devices was associated with increased late loss. Device selection used as adjunctive therapy did not influence the 30-day outcome. Patients treated with gamma radiation and placebo therapy had similar rates of composite major adverse coronary events (MACE) (death, Q-wave myocardial infarction, target vessel revascularization) (3% vs 2%, p = NS). At 6 months, MACE rates in irradiated patients were similar among POBA (29%), ELCA (28%), rotational atherectomy (18%), and additional stent implantation (30%, p = NS), and were significantly lower compared with placebo for the entire cohort and for each device subgroup. The overall recurrence rate of ISR was lower in patients treated with gamma radiation using iridium-192 compared with placebo. Device selection did not influence late clinical outcomes in irradiated and nonirradiated groups.
Collapse
Affiliation(s)
- Andrew E Ajani
- Vascular Brachytherapy Institute, Cardiology Research Institute, Washington Hospital Center, Washington, DC 20010, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Hehrlein C, DeVries JJ, Arab A, Haller SD, Schloesser K, Tio FO, Fischell TA. Failure of a novel balloon-expandable gamma-emitting ((103)Pd) stent to prevent edge effects. Circulation 2001; 104:2358-62. [PMID: 11696478 DOI: 10.1161/hc4401.098469] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Balloon-expandable beta-particle-emitting ((32)P) stents inhibit within-stent neointimal hyperplasia but induce lumen narrowing beyond the stent margins, ie, the so-called "edge effects." METHODS AND RESULTS We prospectively investigated the performance of novel stents impregnated with the gamma-emitting isotope (103)Pd, designed to reduce edge effects, in 24 rabbits. The stents had a length of 18 mm and were mounted on 20-mm-long delivery balloons for deployment. Angiograms were obtained immediately and 1 month after direct implantation of control and 1-, 2-, and 4-mCi (103)Pd stents into the iliac arteries without predilatation or postdilatation. Late lumen loss was measured with quantitative angiography. Neointimal hyperplasia and vascular remodeling were evaluated by histomorphometry. Late lumen loss was inhibited within (103)Pd stents (control 0.18 mm, 1 mCi 0.08 mm, 2 mCi 0.05 mm, and 4 mCi -0.03 mm, P<0.05 all activities versus control). Conversely, late lumen loss occurred at the edges of (103)Pd stents, correlating with areas of high balloon/artery ratios and vessel overstretch injury. Edge effects were primarily due to neointimal hyperplasia but were also caused by negative vessel remodeling at high stent activities. CONCLUSIONS Edge effects after implantation of radioisotope stents can occur independently of the isotope chosen for stent impregnation.
Collapse
Affiliation(s)
- C Hehrlein
- Department of Cardiology, University of Freiburg, and the Forschungszentrum Karlsruhe, Germany.
| | | | | | | | | | | | | |
Collapse
|
14
|
Kwok PC, Wong KM, Ngan RK, Chan SC, Wong WK, Wong KY, Wong AK, Chau KF, Li CS. Prevention of recurrent central venous stenosis using endovascular irradiation following stent placement in hemodialysis patients. Cardiovasc Intervent Radiol 2001; 24:400-6. [PMID: 11907747 DOI: 10.1007/s00270-001-0034-6] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
This study was done to evaluate the outcome after brachytherapy (BT) given to prevent restenosis after stent insertion for central venous stenosis in patients with ipsilateral hemodialysis arteriovenous fistulas (AVF). Angioplasty and stenting were performed on 9 primary central venous stenoses in 8 patients with AVF followed by BT, delivering Iridium-192 radiation using an afterloading technique. BT was also administered to three patients with five recurrent stenoses at the stent margins. There was no residual stenosis after angioplasty and stenting. Venographic follow-up (77-644 days, mean 272 days) showed no restenosis in seven primary stenoses. New strictures (45%-100%) developed at the stent margin in six veins (five patients). Angioplasty or stenting was performed for five margin stenoses in three patients, followed by a second BT. Residual stenosis before BT was 0-30%. In our venographic follow-up (140-329 days, mean 215 days), three restenoses occurred (35%-100%). All progressed to complete occlusion on later venographic follow-up irrespective of whether BT was given to the stent margin or not. The mean primary and assisted primary patency of the central veins were 359 days and 639 days, respectively. Endovascular irradiation with a noncentering source does not prolong the patency after angioplasty and stenting of central venous stenosis in hemodialysis patients.
Collapse
Affiliation(s)
- P C Kwok
- Department of Radiology and Imaging, Queen Elizabeth Hospital, Kowloon, Hong Kong
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
van Der Giessen WJ, Regar E, Harteveld MS, Coen VL, Bhagwandien R, Au A, Levendag PC, Ligthart J, Serruys PW, den Boer A, Verdouw PD, Boersma E, Hu T, van Beusekom HM. "Edge Effect" of (32)p radioactive stents is caused by the combination of chronic stent injury and radioactive dose falloff. Circulation 2001; 104:2236-41. [PMID: 11684637 DOI: 10.1161/hc4301.097873] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called "edge effect." To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactive dose-falloff zone next to a nonradioactive stent-artery transition at one side and a radioactive stent-artery transition at the other side. METHODS AND RESULTS Half-radioactive stents (n=20) and nonradioactive control stents (n=10) were implanted in the coronary arteries of Yucatan micropigs. Animals received aspirin and clopidogrel as antithrombotics. After 4 weeks, a significant midstent stenosis was observed by angiography in the half-radioactive stents. Two animals died suddenly because of coronary occlusion at this mid zone at 8 and 10 weeks. At 12-week follow-up angiography, intravascular ultrasound and histomorphometry showed a significant neointimal thickening at the midstent dose-falloff zone of the half-radioactive stents, but not at the stent-to-artery transitions at both extremities. Such a midstent response (mean angiographic late loss 1.0 mm) was not observed in the nonradioactive stents (mean loss 0.4 to 0.6 mm; P< 0.01). CONCLUSIONS The edge effect of high-dose radioactive stents in porcine coronary arteries is associated with the combination of stent injury and radioactive dose falloff.
Collapse
Affiliation(s)
- W J van Der Giessen
- Department of Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Illig KA, Williams JP, Lyden SP, Hernady E, Soni A, Davies MG, Schell M, Okunieff P, Rubin P, Green RM. External beam irradiation for inhibition of intimal hyperplasia following prosthetic bypass: preliminary results. Ann Vasc Surg 2001; 15:533-8. [PMID: 11665436 DOI: 10.1007/s10016-001-0004-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
To determine whether external beam irradiation delivered immediately after graft implantation can inhibit anastomotic intimal hyperplasia (IH) 1 month following polytetrafluoroethylene (PTFE) bypass in a sheep carotid artery model, 23 sheep underwent bilateral bypass of the ligated common carotid artery with 8-mm PTFE immediately followed by a single dose of irradiation (15, 21, or 30 Gy) to one side. The 15 animals with bilaterally patent grafts were euthanized at 1 month and graft-arterial anastomoses harvested. Using computer-aided image analysis, IH areas and thicknesses were measured. Graft patency in this model was 83% at 1 month and did not differ according to treatment administered. In the control animals, IH was greatest at mid-anastomosis, but minimal within the native vessel. All three radiation doses markedly inhibited mid-anastomotic IH area and thickness. At the proximal anastomosis, 30 Gy reduced the IH area 20-fold, from 2.06 to 0.14 mm2 (p < 0.0001 by ANOVA), and IH thickness 70-fold, from 29.0 to 0.4 micron (p < 0.0002); similar effects were seen at the distal anastomosis. No adverse effects of radiation treatment were observed. External beam irradiation in doses of 15 to 30 Gy delivered in a single fraction immediately after operation markedly inhibits development of intimal hyperplasia 1 month following end-to-side anastomosis with PTFE in sheep.
Collapse
Affiliation(s)
- K A Illig
- Division of Vascular Surgery, University of Rochester Medical Center, 601 Elmwood Avenue, Box 652, Rochester, NY 14642, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Ahmed JM, Mintz GS, Waksman R, Mehran R, Leiboff B, Pichard AD, Satler LF, Kent KM, Weissman NJ. Serial intravascular ultrasound assessment of the efficacy of intracoronary gamma-radiation therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions. Circulation 2001; 104:856-9. [PMID: 11514368 DOI: 10.1161/hc3301.095285] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The efficacy of coronary gamma-irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. METHODS AND RESULTS We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma-irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P=0.0064 and P=0.0125, respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0+/-1.4 mm(2)); areas were 2.9+/-1.0 mm(2) in irradiated patients in Long WRIST and 1.9+/-1.1 mm(2) in placebo patients in Long WRIST (P<0.005 for all comparisons). CONCLUSIONS - Serial IVUS analysis shows that gamma-irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.
Collapse
Affiliation(s)
- J M Ahmed
- Intravascular Ultrasound Imaging and Cardiac Catheterization Laboratories, Cardiovascular Research Institute, Washington Hospital Center, Washington, DC 20010, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Waksman R, Ajani AE, White RL, Pinnow E, Mehran R, Bui AB, Deible R, Gruberg L, Mintz GS, Satler LF, Pichard AD, Kent KM, Lindsay J. Two-year follow-up after beta and gamma intracoronary radiation therapy for patients with diffuse in-stent restenosis. Am J Cardiol 2001; 88:425-8. [PMID: 11545769 DOI: 10.1016/s0002-9149(01)01694-0] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- R Waksman
- Washington Hospital Center, Washington, DC 20010, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Rectenwald JE, Pretus HA, Seeger JM, Huber TS, Mendenhall NP, Zlotecki RA, Palta JR, Li ZF, Hook SY, Sarac TP, Welborn MB, Klingman NV, Abouhamze ZS, Ozaki CK. External-beam radiation therapy for improved dialysis access patency: feasibility and early safety. Radiat Res 2001; 156:53-60. [PMID: 11418073 DOI: 10.1667/0033-7587(2001)156[0053:ebrtfi]2.0.co;2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Rectenwald, J. E., Pretus, H. A., Seeger, J. M., Huber, T. S., Mendenhall, N. P., Zlotecki, R. A., Palta, J. R., Li, Z. F., Hook, S. Y., Sarac, T. P., Welborn, M. B., Klingman, N. V., Abouhamze, Z. S. and Ozaki, C. K. External-Beam Radiation Therapy for Improved Dialysis Access Patency: Feasibility and Early Safety. Radiat. Res. 156, 53-60 (2001).Prosthetic dialysis access grafts fail secondary to neointimal hyperplasia at the venous anastomosis. We hypothesized that postoperative single-fraction external-beam radiation therapy to the venous anastomosis of hemodialysis grafts can be used safely in an effort to improve access patency. Dogs (n = 8) underwent placement of expanded polytetrafluoroethylene grafts from the right carotid artery to the left jugular vein. Five dogs received single-fraction external-beam photon irradiation (8 Gy) to the venous anastomosis after surgery. Controls were not irradiated. Shunt angiograms were completed 3 and 6 months postoperatively. Anastomoses, mid-graft, and the surrounding tissues were analyzed. Immunohistochemistry for smooth muscle cell alpha-actin, proliferating cellular nuclear antigen (PCNA), and apoptosis was performed. Incisions healed well, though all animals developed wound seromas. One control suffered graft thrombosis 4 months postoperatively. Angiography/histology confirmed severe neointimal hyperplasia at the venous anastomosis. The remaining seven dogs developed similar amounts of neointimal hyperplasia. PCNA studies showed no accelerated fibroproliferative response at irradiated anastomoses compared to controls. Skin incisions and soft tissues over irradiated anastomoses revealed no radiation-induced changes or increase in apoptosis. Thus we conclude that postoperative single-fraction external-beam irradiation of the venous anastomosis of a prosthetic arteriovenous graft that mimics the situation in humans is feasible and safe with regard to early wound healing.
Collapse
Affiliation(s)
- J E Rectenwald
- Department of Surgery, University of Florida College of Medicine, Gainesville, FL 32610, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
De Scheerder IK, Wang K, Kaul U, Singh B, Sahota H, Keelan MH, Kipshidze NN, Moses J. Intravascular low-power laser irradiation after coronary stenting: long-term follow-up. Lasers Surg Med 2001; 28:212-5. [PMID: 11295754 DOI: 10.1002/lsm.1040] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND AND OBJECTIVE A high restenosis rate remains a limiting factor for percutaneous transluminal coronary angioplasty and stenting. The objective of this study was to evaluate the effect of intravascular red laser therapy (IRLT) on restenosis after stenting procedures in de novo lesions. STUDY DESIGN/MATERIALS AND METHODS A total of 68 consecutive patients were treated with IRLT in conjunction with coronary stenting procedures. Mean lesion length was 16.5 +/- 2.4 mm. Reference vessel diameter (RVD) and pre-minimal lumen diameter (MLD) were 2.90 +/- 0.15 mm and 1.12 +/- 0.26 mm, respectively. RESULTS After treatment, MLD was 2.76 +/- 0.32 mm with no procedural complications or in-hospital adverse events. Angiographic follow-up (n = 61) revealed restenosis in nine patients (14.7%) with rate by artery size of > 3 mm (n = 21) 0%; 2.5--3.0 mm (n = 28) 14.2%; and < 2.5 mm (n = 12) 41.6%. CONCLUSION Intravascular red light therapy is safe, feasible, and reduces expected restenosis rate after coronary stenting.
Collapse
|
21
|
Kałuza GL, Raizner AE, Mazur W, Schulz DG, Buergler JM, Fajardo LF, Tio FO, Ali NM. Long-term effects of intracoronary beta-radiation in balloon- and stent-injured porcine coronary arteries. Circulation 2001; 103:2108-13. [PMID: 11319203 DOI: 10.1161/01.cir.103.16.2108] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The data on the long-term safety and efficacy of intracoronary beta-radiation in animal models are limited. METHODS AND RESULTS A total of 30 coronary arteries in 15 swine were subjected to balloon or stent injury followed by beta-radiation from a centered 32P source (2000 cGy to 1 mm beyond lumen surface) or a sham radiation procedure. The animals received aspirin for 6 months and ticlopidine for 30 days. Five of the 10 animals subjected to radiation died (at 5 days, 7 days, 3 months [n = 2], and 4 months) as a result of layered, occlusive thrombus at the intervention site (3 stent and 2 balloon injury sites). No deaths occurred in the control group. In the surviving animals, balloon-injured and irradiated vessels showed a trend toward larger lumens than controls (2.15 +/- 0.17 versus 1.80 +/- 0.08 mm2, P=0.06) and larger external elastic lamina areas (3.32 +/- 0.21 versus 2.62 +/- 0.10 mm2, P=0.003). In the stent-injured vessels from surviving animals, lumen, neointimal, and external elastic lamina areas were 3.58 +/- 0.33, 3.16 +/- 0.35, and 8.12 +/- 0.42 mm2 for irradiated vessel segments; these values were not different from those in controls (3.21 +/- 0.15, 2.84 +/- 0.27, and 7.76 +/- 0.28 mm2, respectively). Histologically, healing was complete in most survivors, although intramural fibrin and hemorrhage were occasionally seen. CONCLUSION In the long-term (6 month) porcine model of restenosis, the inhibition by intracoronary beta-radiotherapy of the neointimal formation that is known to be present at 1 month is not sustained. This lack of effect on neointimal formation after balloon and stent arterial injury is accompanied by subacute and late thrombosis that leads to cardiac death on a background of continuous aspirin but relatively brief ticlopidine treatment.
Collapse
Affiliation(s)
- G L Kałuza
- Department of Medicine, Veterans Affairs Medical Center and Baylor College of Medicine, Houston, TX 77030, USA
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Bass LS, Oz MC, Libutti SK, Treat MR. Alternative wavelengths for sutureless laser microvascular anastomosis: a preliminary study on acute samples. J Clin Laser Med Surg 1992; 10:207-10. [PMID: 10147865 DOI: 10.1089/clm.1992.10.207] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Attempts to improve the speed and patency of microvascular anastomosis with laser-assisted techniques have provided a modest reduction in operative time and comparable success rates. Using sutureless microvascular anastomoses, 30 end-to-end anastomoses were created in the rat carotid artery using the gallium-aluminum-arsenide diode laser (808 nm). Indocyanine green and fibrinogen were applied to enhance tissue absorption of the laser energy and strengthen the bond created. These were compared with previously reported welds using the THC:YAG laser (2150 nm). Mean welding times were 140 and 288 s, and mean bursting pressures immediately after welding were 515 and 400 mmHg for the diode and THC:YAG laser groups, respectively. Histologically, both lateral and vertical spread of thermal damage was limited. Since both lasers create welds of adequate initial strength without stay sutures and are faster and easier to use than existing systems, evaluation of long-term patency would be worthwhile.
Collapse
Affiliation(s)
- L S Bass
- Institute of Reconstructive Plastic Surgery, NYU Medical Center
| | | | | | | |
Collapse
|