1
|
Systematic Review Between Resting-State fMRI and Task fMRI in Planning for Brain Tumour Surgery. J Multidiscip Healthc 2024; 17:2409-2424. [PMID: 38784380 PMCID: PMC11111578 DOI: 10.2147/jmdh.s470809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Accepted: 05/13/2024] [Indexed: 05/25/2024] Open
Abstract
As an alternative to task-based functional magnetic resonance imaging (T-fMRI), resting-state functional magnetic resonance imaging (Rs-fMRI) is suggested for preoperative mapping of patients with brain tumours, with an emphasis on treatment guidance and neurodegeneration prediction. A systematic review was conducted of 18 recent studies involving 1035 patients with brain tumours and Rs-fMRI protocols. This was accomplished by searching the electronic databases PubMed, Scopus, and Web of Science. For clinical benefit, we compared Rs-fMRI to standard T-fMRI and intraoperative direct cortical stimulation (DCS). The results of Rs-fMRI and T-fMRI were compared and their correlation with intraoperative DCS results was examined through a systematic review. Our exhaustive investigation demonstrated that Rs-fMRI is a dependable and sensitive preoperative mapping technique that detects neural networks in the brain with precision and identifies crucial functional regions in agreement with intraoperative DCS. Rs-fMRI comes in handy, especially in situations where T-fMRI proves to be difficult because of patient-specific factors. Additionally, our exhaustive investigation demonstrated that Rs-fMRI is a valuable tool in the preoperative screening and evaluation of brain tumours. Furthermore, its capability to assess brain function, forecast surgical results, and enhance decision-making may render it applicable in the clinical management of brain tumours.
Collapse
|
2
|
Review - Plant nutritional status analysis employing the visible and near-infrared spectroscopy spectral sensor. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 304:123273. [PMID: 37666099 DOI: 10.1016/j.saa.2023.123273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 08/12/2023] [Accepted: 08/16/2023] [Indexed: 09/06/2023]
Abstract
Experiments demonstrated that visible and near-infrared (Vis-NIR) spectroscopy is a highly reliable tool for determining the nutritional status of plants. Although numerous studies on various kinds of plants have been conducted, there are only a few summaries of the research findings regarding the absorbance bands in the visible and near-infrared region and how they relate to the nutritional status of plants. This article will discuss the application of Vis-NIR spectroscopy for monitoring the nutrient conditions of plants, with a particular emphasis on three major components required by plants, namely nitrogen (N), phosphorus (P), and potassium (K), or NPK. Each section discussed different topics, for instance, the essential nutrients needed by plants, the application of Vis-NIR spectroscopy in nutrient status analysis, chemometrics tools, and absorbance bands related to the nutrient status, respectively. Deduction made concluded that factors affecting the plant's structure are contributed by several circumstances like the age of leaves, concentration of pigments, and water content. These factors are intertwined, strongly correlated, and can be observed in the visible and near-infrared regions. While the visible region is commonly utilised for nutritional analysis in plants, the literature review performed in this paper shows that the near-infrared region as well contains valuable information about the plant's nutritional status. A few wavelengths related to the direct estimation of nutrients in this review explained that information on nutrients can be linked with chlorophyll and water absorption bands such that N and P are the components of chlorophyll and protein; on the other hand, K exists in the form of cationic carbohydrates which are sensitive to water region.
Collapse
|
3
|
Optical absorbance of RGB LEDs in pH measurement of colorimetric solution with phenol red reagent. INDONESIAN JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE 2022; 27:1330. [DOI: 10.11591/ijeecs.v27.i3.pp1330-1337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
The use of red, green, and blue ( RGB ) light-emitting-diode ( LED ) is a new trend in monochromatic colorimetric sensing due to cost-effective implementation. However, the application of RGB LED in pH measurement depends on the performance of the LED colour towards the colorimetric solution of interest, hence, needs to be evaluated. This work evaluated the performance of RGB LED for pH measurement system based on colorimetric approach using phenol red as a reagent. The main objective was to identify the LED colour with the best performance in terms of signal response and a bsorbance behavior. In this work, LED and photodiode were used as optical components and NI USB DAQ with LabView as the processing software. Four samples with known pH values were prepared and tested to obtain the voltage and absorbance behavior of each LED colour. Among all, the blue LED with wavelength ranged between 450 - 495 nm showed the best sensing behavior based on its linearity and error. Both voltage response and absorbance produced linear correlation with R 2=0.883 and R 2=0.9803, respectively. The significant finding from this study is useful in selecting the best RGB LED that is suitable for colorimetric pH measurement with phenol red as its colorimetric reagent.
Collapse
|
4
|
Expired EBT3 Films’ Sensitivity for the Measurement of X-ray and UV Radiation: An Optical Analysis. MATERIALS 2022; 15:ma15082903. [PMID: 35454597 PMCID: PMC9027090 DOI: 10.3390/ma15082903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 03/15/2022] [Accepted: 04/13/2022] [Indexed: 11/25/2022]
Abstract
The aim of this study is to compare the optical responses of external beam therapy 3 (EBT3) films exposed to X-rays and solar ultraviolet rays (SUV-rays), as a dose control technique in the clinical sector for various radiation types, energies, and absorbed doses up to 4 Gy. In this study, EBT3 films with three different expiry dates were prepared and cut into pieces of size 2 by 2 cm2. The first group was exposed to 90 kVp X-rays, while the second group was exposed to the SUV-rays at noon. The analysis was performed using a visible Jaz spectrometer and an EPSON Perfection V370 Photo scanner to obtain the absorbance, the net reflective optical density (ROD) and the red-green-blue (RGB) values of the samples. The results have shown that spectroscopic measurements of the exposed expired EBT3 films with these radiation sources are able to produce primary peaks and secondary peaks at λ = 641.74 nm and λ = 585.98 nm for X-rays, and at λ = 637.93 nm and λ = 584.45 nm for SUV-rays, respectively. According to these findings, compared to 2021 films that expired shortly before the trial start date; 2018 films responded better to the absorbed dose than 2016 films when exposed to both X-ray and SUV-rays. In terms of energy dependence, the expired EBT3 2018 had the largest net ROD value. Using L*a*b* indices extracted from the RGB data, and despite that EBT3 films have expiry dates according to the manufacturer; all the films exhibited a substantial colour change, indicating that these films are still usable for clinical and research purposes.
Collapse
|
5
|
Identification of Stingless Bee Honey Adulteration Using Visible-Near Infrared Spectroscopy Combined with Aquaphotomics. Molecules 2022; 27:molecules27072324. [PMID: 35408723 PMCID: PMC9000493 DOI: 10.3390/molecules27072324] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 03/28/2022] [Accepted: 04/01/2022] [Indexed: 11/17/2022] Open
Abstract
Honey is a natural product that is considered globally one of the most widely important foods. Various studies on authenticity detection of honey have been fulfilled using visible and near-infrared (Vis-NIR) spectroscopy techniques. However, there are limited studies on stingless bee honey (SBH) despite the increase of market demand for this food product. The objective of this work was to present the potential of Vis-NIR absorbance spectroscopy for profiling, classifying, and quantifying the adulterated SBH. The SBH sample was mixed with various percentages (10−90%) of adulterants, including distilled water, apple cider vinegar, and high fructose syrup. The results showed that the region at 400−1100 nm that is related to the color and water properties of the samples was effective to discriminate and quantify the adulterated SBH. By applying the principal component analysis (PCA) on adulterants and honey samples, the PCA score plot revealed the classification of the adulterants and adulterated SBHs. A partial least squares regression (PLSR) model was developed to quantify the contamination level in the SBH samples. The general PLSR model with the highest coefficient of determination and lowest root means square error of cross-validation (RCV2=0.96 and RMSECV=5.88 %) was acquired. The aquaphotomics analysis of adulteration in SBH with the three adulterants utilizing the short-wavelength NIR region (800−1100 nm) was presented. The structural changes of SBH due to adulteration were described in terms of the changes in the water molecular matrix, and the aquagrams were used to visualize the results. It was revealed that the integration of NIR spectroscopy with aquaphotomics could be used to detect the water molecular structures in the adulterated SBH.
Collapse
|
6
|
Investigations into Ag nanoparticles–carbon–poly(9,9-di-n-octylfluorenyl-2,7-diyl) (PFO) composite: morphological, structural, optical, and electrical characterization. Polym Bull (Berl) 2021. [DOI: 10.1007/s00289-021-03938-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
7
|
Development and characterization of an LED-based detector for dosimetry in diagnostic radiology. Phys Med Biol 2021; 66. [PMID: 33725685 DOI: 10.1088/1361-6560/abef44] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 03/16/2021] [Indexed: 11/12/2022]
Abstract
Light-emitting diodes (LEDs) could be a potential dosimetry candidate because they are radiation hard, spectrally selective, direct band gap, and low-cost devices. Thus, an LED-based detector prototype was designed and characterized for dosimetry. A 20 × 20 cm2 array of surface mount device LED chips was sandwiched in photovoltaic mode between two intensifying screens to form a dosimetric system. The system was enclosed in a light-tight air cavity using black vinyl tape. The screens converted diagnostic X-ray beams into fluorescent blue light. LEDs, applied in detector mode, converted the fluorescent light into radiation-induced currents. A digital multimeter converted the analog currents into digital voltage signals. Prototype characterization was executed using (a) IEC 61267's RQR 7 (90 kVp) and RQR 8 (100 kVp) beam qualities, and (b) low (25 mAs) and high (80 mAs) beam quantities. A standard dosimeter probe was simultaneously exposed with the prototype to measure the prototype's absorbed dose. In all exposures, the X-ray beams were perpendicularly incident on both the dosimeter and prototype, at a fixed source to detector distance-60 cm. The LED array prototype's minimum detectable dose was 0.139 mGy, and the maximum dose implemented herein was ~ 13 mGy. The prototype was 99.18 % and 98.64 % linearly sensitive to absorbed dose and tube current-time product (mAs), respectively. The system was ± 4.69 % energy, ± 6.8 % dose, and ± 7.7 % dose rate dependent. Two prototype data sets were 89.93 % repeatable. We fabricated an ultrathin (5 mm), lightweight (130 g), and a relatively low-cost LED-based dosimetric prototype. The prototype executed a simple, efficient, and accurate real-time dosimetric mechanism. It could thus be an alternative to the current passive dosimetric systems.
Collapse
|
8
|
Application of Bpw34 photodiode and cold white LED as diagnostic X-ray detectors: A comparative analysis. Appl Radiat Isot 2021; 170:109622. [PMID: 33592486 DOI: 10.1016/j.apradiso.2021.109622] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 12/17/2020] [Accepted: 01/26/2021] [Indexed: 11/25/2022]
Abstract
This study compares the real-time dosimetric performance of a bpw34 photodiode (PD) and cold white light-emitting diodes (LEDs) based on diagnostic X-ray-induced signals. Signals were extracted when both the transducers were under identical exposure settings, including source-to-detector distance (SDD), tube voltage (kVp), and current-time product (mAs). The transducers were in a photovoltaic configuration, and black vinyl tape was applied on transducer active areas as a form of optical shielding. X-ray beam spectra and energies were simulated using Matlab-based Spektr functions. Transducer performance analysis was based on signal linearity to mAs and air kerma, and sensitivity dependence on absorbed dose, energy, and dose rate. Bpw34 PD and cold white LED output signals were 84.8% and 85.5% precise, respectively. PD signals were 94.7% linear to mAs, whereas LED signals were 91.9%. PD and LED signal linearity to dose coefficients were 0.9397 and 0.9128, respectively. Both transducers exhibited similar dose and energy dependence. However, cold white LEDs were 0.73% less dose rate dependent than the bpw34 PD. Cold white LEDs demonstrated potential in detecting diagnostic X-rays because their performance was similar to that of the bpw34 PD. Moreover, the cold white LED array's dosimetric response was independent of the heel effect. Although cold white LED signals were lower than bpw34 PD signals, they were quantifiable and electronically amplifiable.
Collapse
|
9
|
Current-Voltage Response of Cold White LED Strip to Radiotherapeutic Electron and Photon Beams: A Preliminary Study. ACTA ACUST UNITED AC 2020. [DOI: 10.1088/1742-6596/1505/1/012008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
VIS-NIR spectral signature and quantitative analysis of HeLa and DU145 cell line. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 222:117241. [PMID: 31216502 DOI: 10.1016/j.saa.2019.117241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 06/01/2019] [Accepted: 06/05/2019] [Indexed: 06/09/2023]
Abstract
Cancer is increasing in incidence and the leading cause of death worldwide. Controlling and reducing cancer requires early detection and technique to accurately detect and quantify predictive biomarkers. Optical spectroscopy has shown promising non-destructive ability to display distinctive spectral characteristics between cancerous and normal tissues from different part of human organ. Nonetheless, not many information is available on spectroscopic properties of cancer cell lines. In this research, the visible-near infrared (VIS-NIR) absorbance spectroscopy measurement of cultured cervical cancer (HeLa) and prostate cancer cells (DU145) lines has been performed to develop spectral signature of cancer cells and to generate algorithm to quantify cancer cells. Spectroscopic measurement on mouse skin fibroblast (L929) was also taken for comparative purposes. In visible region, the raw cells' spectra do not produce any noticeable peak absorbance that provides information on color because the medium used for cells is colorless and transparent. NIR wavelength between 950 and 975 nm exhibit significant peak due to water absorbance by the medium. Development of spectral signature for the cells through the application of regression technique significantly enhances the diverse characteristics between L929, HeLa and DU145. The application of multiple linear regression allows high measurement accuracy of the cells with coefficient of determination above 0.94.
Collapse
|
11
|
Potential colorimetric detection of cancer cells using Phenol Red. Photodiagnosis Photodyn Ther 2019; 27:380-384. [PMID: 31301437 DOI: 10.1016/j.pdpdt.2019.07.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 05/23/2019] [Accepted: 07/08/2019] [Indexed: 02/04/2023]
Abstract
The objective of this research is to examine the relationship between the color changes of phenol red and the growth of cancer cells, i.e., HeLa and DU145 cells, over a specific period of time. Normal mouse skin fibroblasts (L929 cells) were used as a reference. In this research, the color changes of phenol red due to the acidification of the cell culture medium from the growth of the cells over a period of nine hours showed potential colorimetric characteristics of cancer cells. The color changes of phenol red were observed using visible absorbance spectroscopy. The transformation of the absorbance spectra into coefficients of determination against the examined range of wavelengths created a distinctive spectral signature that signifies phenol red discoloration in cancer and normal cell culture lines.
Collapse
|
12
|
A Review: Photonic Devices Used for Dosimetry in Medical Radiation. SENSORS 2019; 19:s19102226. [PMID: 31091779 PMCID: PMC6567371 DOI: 10.3390/s19102226] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Revised: 05/08/2019] [Accepted: 05/09/2019] [Indexed: 11/28/2022]
Abstract
Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) are used to measure and monitor radiation in medical applications. Of recent, photonic devices have also been adopted. This article evaluates recent research and advancements in the applications of photonic devices in medical radiation detection primarily focusing on four types; photodiodes – including light-emitting diodes (LEDs), phototransistors—including metal oxide semiconductor field effect transistors (MOSFETs), photovoltaic sensors/solar cells, and charge coupled devices/charge metal oxide semiconductors (CCD/CMOS) cameras. A comprehensive analysis of the operating principles and recent technologies of these devices is performed. Further, critical evaluation and comparison of their benefits and limitations as dosimeters is done based on the available studies. Common factors barring photonic devices from being used as radiation detectors are also discussed; with suggestions on possible solutions to overcome these barriers. Finally, the potentials of these devices and the challenges of realizing their applications as quintessential dosimeters are highlighted for future research and improvements.
Collapse
|
13
|
EBT3 Films in Low Solar Ultraviolet and X-Ray Dose Measurement: A Comparative Analysis. Dose Response 2019; 17:1559325819855532. [PMID: 31236089 PMCID: PMC6572892 DOI: 10.1177/1559325819855532] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Revised: 04/27/2019] [Accepted: 05/14/2019] [Indexed: 11/14/2022] Open
Abstract
The purpose of this study is to investigate the potentiality of Gafchromic external beam therapy 3 (EBT3) film to measure low dosage of solar ultraviolet (SUV; 0-10 600 mJ/cm2) and x-ray (0-750 mGy) radiation. In this experiment, 2 groups of EBT3 films were prepared with size 2 cm × 1 cm. The first group of films was exposed by incremental SUV dose in the middle of the day. The other group was irradiated by x-ray at 100 kVp, 100 mA, and 2 S of tube voltage, tube current, and exposure time, respectively. The measured SUV consists of 90% ultraviolet A (UVA) and 10% ultraviolet B. The film discoloration was represented by visible absorbance spectroscopy technique using Jaz spectrometer from Ocean Optics Inc. Simple linear regression produced high accuracy with coefficients of determination, r 2 of 0.9804 and root mean square error (RMSE) of 434.88 mJ/cm2 for the measurement of SUV dose. On the other hand, r 2 of 0.98 and RMSE of 31 mGy was produced for the measurement of x-ray dose. The application of multiple linear regression enhanced the measurement accuracy with R 2 of 99% and 99.7% and RMSE of 327.06 mJ/cm2 and 15.045 mGy for SUV and x-ray dose, respectively. The spectral analysis shows a promising measurement at selected wavelengths for SUV and x-ray dose.
Collapse
|
14
|
Sensing mechanism of water turbidity using LED for in situ monitoring system. 2017 IEEE 7TH INTERNATIONAL CONFERENCE ON UNDERWATER SYSTEM TECHNOLOGY: THEORY AND APPLICATIONS (USYS) 2017. [DOI: 10.1109/usys.2017.8309443] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
15
|
Visible Spectral Linearisation, Gradient Shift and Normalisation in Quantifying Carambola Acidity. FOOD BIOPHYS 2012. [DOI: 10.1007/s11483-012-9267-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|