1
|
An application example of the likelihood ratio approach to the evaluation of organic gunshot residues using a fictional scenario and recently published data. Forensic Sci Int 2022; 335:111267. [DOI: 10.1016/j.forsciint.2022.111267] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/02/2022] [Accepted: 03/04/2022] [Indexed: 11/04/2022]
|
2
|
Use of ion mobility-high resolution mass spectrometry in metabolomics studies to provide near MS/MS quality data in a single injection. JOURNAL OF MASS SPECTROMETRY : JMS 2021; 56:e4718. [PMID: 33813797 DOI: 10.1002/jms.4718] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 03/03/2021] [Accepted: 03/06/2021] [Indexed: 06/12/2023]
Abstract
The use of ion mobility separations (IMSs) in metabolomics approaches has started to be deeply explored in the last years. In this work, the use of liquid chromatography (LC) coupled to IMS-quadrupole time-of-flight mass spectrometry (QTOF MS) has been evaluated in a metabolomics experiments using single injection of the samples. IMS has allowed obtaining cleaner fragmentation spectra, of nearly tandem MS quality, in data-independent acquisition mode. This is much useful in this research area as a second injection, generally applied in LC-QTOF MS workflows to obtain tandem mass spectra, is not necessary, saving time and evading possible compound degradation. As a case study, the smoke produced after combustion of herbal blends used to spray synthetic cannabinoids has been selected as study matrix. The smoke components were trapped in carbon cartridges, desorbed and analyzed by LC-IMS-QTOF MS using different separation mechanisms (reversed phase and HILIC) and acquiring in both positive and negative mode to widen the chemical domain. Partial Least Squares-Discriminant Analysis highlighted several compounds, and ratio between N-Isopropyl-3-(isoquinolinyl)-2-propen-1-amine and quinoline allowed differentiating between tobacco and herbal products. These two compounds were tentatively identified using the cleaner fragmentation spectra from a single injection in the IMS-QTOF MS, with additional confidence obtained by retention time (Rt) and collisional cross section (CCS) prediction using artificial neural networks. Data from this work show that LC-IMS-QTOF is an efficient technique in untargeted metabolomics, avoiding re-injection of the samples for elucidation purposes. In addition, the prediction models for Rt and CCS resulted of help in the elucidation process of potential biomarkers.
Collapse
|
3
|
Prevalence of organic gunshot residues in police vehicles. Sci Justice 2020; 60:136-144. [PMID: 32111286 DOI: 10.1016/j.scijus.2019.09.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 09/13/2019] [Accepted: 09/22/2019] [Indexed: 11/15/2022]
Abstract
The present study investigated the organic gunshot residue (OGSR) background level of police vehicles in Switzerland. Specimens from 64 vehicles belonging to two regional police services were collected and analysed by LC-MS in positive mode. The driver's and back seats were sampled separately to monitor potential differences between locations and to assess the risks of a suspect being contaminated by OGSR during transportation to a police station. The results showed that most of the 64 vehicles were uncontaminated (44 driver's seats and 38 back seats respectively). Up to six of the seven targeted compounds were detected in a single sample, once on a driver's seat and twice on back seats. The contamination frequency generally decreased as the number of compounds detected together increased. The amounts detected were in the low ng range and less than amounts generally detected just after discharge on a shooter. Our data indicated that detecting a combination of four or more compounds on a police vehicle seat appears to be a relatively rare occurrence. The background contamination observed was most probably due to secondary transfer from police officers (e.g. through recent participation in a shooting session or firearm manipulation) or from firearms stored in the vehicles. The present results might be used as a recommendation to minimize contact of a suspect with contaminated surfaces if OGSR is implemented in routine work in parallel to IGSR analysis.
Collapse
|
4
|
Comparison of three collection methods for the sodium rhodizonate detection of gunshot residues on hands. Sci Justice 2020; 60:63-71. [PMID: 31924290 DOI: 10.1016/j.scijus.2019.09.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 08/05/2019] [Accepted: 09/15/2019] [Indexed: 11/28/2022]
Abstract
The aim of this study was to compare three gunshot residue (GSR) collection methods used in conjunction with chemographic detection applied by different regional Swiss police services. The specimens were collected from the hands of a shooter with either filter paper (Filter method) or adhesive foil. The adhesive foil was then either applied against photographic paper during visualisation (AF Photo method) or coated with a layer of polyvinyl alcohol (AF PVAL method). The experiments involved two conditions of the examined hands, i.e. dry and humidified. The residues were revealed using the sodium rhodizonate test (SRT). Preliminary tests assessing the possibility of conducting a confirmatory Scanning Electron Microscopy coupled to Energy Dispersive X-ray spectroscopy (SEM/EDX) analysis after the chemographic test were performed on a number of specimens by cutting positive spots and mounting them on stubs. Obtained results were compared in terms of effectiveness - number of positive spots, time requirements, quality of subsequent SEM-EDX analysis, ease of use and cost. The Filter method generally yielded a high-quality detection with both dry and humidified hands, as well as a simple, quick and efficient confirmation by SEM/EDX. The AF Photo performed well on dry hands, but not on humidified hands. The AF PVAL method performance was lower compared to the other methods in both examined conditions of the hands. The SEM/EDX analysis showed that the Filter and AF PVAL method provided satisfactory results when a sufficient carbon coating thickness was applied to the cuttings. It was also observed that the thinner the PVAL layer, the better the quality of the spectra and obtained images in SEM/EDX. Furthermore, the surface of the photographic paper did not seem to be conductive, even after the application of a thick layer of carbon. In conclusion, the Filter method gave the best overall results, but its application required slightly more time and expertise than the two other methods.
Collapse
|
5
|
Surveys of organic gunshot residue prevalence: Comparison between civilian and police populations. Forensic Sci Int 2019; 298:48-57. [DOI: 10.1016/j.forsciint.2019.02.050] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 02/21/2019] [Accepted: 02/25/2019] [Indexed: 10/27/2022]
|
6
|
Abstract
Discrepant results have been reported regarding an intramuscular mechanism underlying the ergogenic effect of caffeine on neuromuscular function in humans. Here, we reevaluated the effect of caffeine on muscular force production in humans and combined this with measurements of the caffeine dose-response relationship on force and cytosolic free [Ca2+] ([Ca2+]i) in isolated mouse muscle fibers. Twenty-one healthy and physically active men (29 ± 9 yr, 178 ± 6 cm, 73 ± 10 kg, mean ± SD) took part in the present study. Nine participants were involved in two experimental sessions during which supramaximal single and paired electrical stimulations (at 10 and 100 Hz) were applied to the femoral nerve to record evoked forces. Evoked forces were recorded before and 1 h after ingestion of 1) 6 mg caffeine/kg body mass or 2) placebo. Caffeine plasma concentration was measured in 12 participants. In addition, submaximal tetanic force and [Ca2+]i were measured in single mouse flexor digitorum brevis (FDB) muscle fibers exposed to 100 nM up to 5 mM caffeine. Six milligrams of caffeine per kilogram body mass (plasma concentration ~40 µM) did not increase electrically evoked forces in humans. In superfused FDB single fibers, millimolar caffeine concentrations (i.e., 15- to 35-fold above usual concentrations observed in humans) were required to increase tetanic force and [Ca2+]i. Our results suggest that toxic doses of caffeine are required to increase muscle contractility, questioning the purported intramuscular ergogenic effect of caffeine in humans.
Collapse
|
7
|
A study of transfer and prevalence of organic gunshot residues. Forensic Sci Int 2017; 277:241-251. [DOI: 10.1016/j.forsciint.2017.06.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Revised: 06/09/2017] [Accepted: 06/12/2017] [Indexed: 11/26/2022]
|
8
|
Organic gunshot residues: Observations about sampling and transfer mechanisms. Forensic Sci Int 2016; 266:369-378. [DOI: 10.1016/j.forsciint.2016.06.029] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2016] [Revised: 06/13/2016] [Accepted: 06/20/2016] [Indexed: 10/21/2022]
|
9
|
Validation of the Mass-Extraction-Window for Quantitative Methods Using Liquid Chromatography High Resolution Mass Spectrometry. Anal Chem 2016; 88:3264-71. [DOI: 10.1021/acs.analchem.5b04689] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
10
|
Treatment with KLEPTOSE® CRYSMEB reduces mouse atherogenesis by impacting on lipid profile and Th1 lymphocyte response. Vascul Pharmacol 2015; 72:197-208. [PMID: 25921922 DOI: 10.1016/j.vph.2015.04.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Revised: 03/05/2015] [Accepted: 04/20/2015] [Indexed: 02/08/2023]
Abstract
The ability of pharmacological agents to target both "classical" risk factors and inflammation may be key for successful outcomes in the prevention and treatment of atherogenesis. Among the promising drugs interfering with cholesterol metabolism, we investigated whether methyl beta-cyclodextrin (KLEPTOSE® CRYSMEB) could positively impact on atherogenesis, lipid profile and atherosclerotic plaque inflammation in ApoE-/- mice. Eleven-week old ApoE-/- mice were fed either a normal diet (N.D.) or a high-cholesterol diet (H.D.), resulting in different levels of hypercholesterolemia. KLEPTOSE® CRYSMEB (40mg/kg) or vehicle was intraperitoneally administrated 3 times per week in the last 16weeks before euthanasia in mice under N.D. and in the last 11weeks under H.D. Treatment with KLEPTOSE® CRYSMEB reduced triglyceride serum levels in both atherogenesis mouse models. In H.D. mice, treatment with KLEPTOSE® CRYSMEB increased HDL-cholesterol levels and reduced free fatty acids and spleen weight. In both mouse models, treatment with KLEPTOSE® CRYSMEB reduced atherosclerotic plaque size in thoraco-abdominal aortas and intraplaque T lymphocyte content, but did not induce relevant improvements in other histological parameters of vulnerability (macrophage, neutrophil, MMP-9 and collagen content). Conversely and more markedly in H.D. mice, treatment with KLEPTOSE® CRYSMEB was associated with a reduction in genetic markers of Th1-mediated immune response. In vitro, KLEPTOSE® CRYSMEB dose-dependently abrogated Th1 proliferation and IFNγ release. In conclusion, treatment with KLEPTOSE® CRYSMEB reduced atherosclerotic plaque size by improving triglyceride serum levels and Th1-mediated response. These results indicate this drug as a potential tool for blocking atheroprogression associated with different severity degrees of hypercholesterolemia.
Collapse
|
11
|
Derivation of uncertainty functions from validation studies in biological fluids: application to the analysis of caffeine and its major metabolites in human plasma samples. J Chromatogr A 2014; 1353:121-30. [PMID: 24925447 DOI: 10.1016/j.chroma.2014.05.047] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 05/06/2014] [Accepted: 05/18/2014] [Indexed: 11/18/2022]
Abstract
Procedures for estimating the measurement uncertainty (MU) of the concentration of a given analyte in a sample are of major concern for analytical chemists. Unfortunately, it is still unclear how and why MU should be assessed. While several possibilities exist, an appropriate approach consists in using method validation data for the evaluation of MU. This was demonstrated by a validation study achieved in the framework of a clinical study related to caffeine in sports medicine, where the results were used for the evaluation of MU. After validation of the method developed using ultra-high pressure liquid chromatography-mass spectrometry for caffeine and its three main metabolites, accuracy profiles were built for each analyte. The first important conclusion is that the developed method was valid for all compounds and met the given specifications for the application (fit for purpose). Relevant estimates of combined standard uncertainty were computed to obtain uncertainty functions, which allow obtaining values of MU as a function of the concentration of the analyte. The great advantage of both uncertainty function and uncertainty profile is the development of a continuous model that enables easy calculation of the standard, expanded and relative expanded uncertainty at any concentration within the validation domain. In fact, the expanded uncertainty interval is assumed to contain 95% of all possible measurements, regardless of the concentration. Finally, the uncertainty function enables the determination of the lowest limit of quantification by selecting adequate acceptance limits, with the limit of quantification being defined as the point where the relative uncertainty equals the acceptance limit threshold. It has to be noted that further discussions remain mandatory to establish which criteria should be applied to define an adequate decision threshold, and the proposal afforded in this work may open new avenues in this direction.
Collapse
|
12
|
Static coatings for the analysis of intact monoclonal antibody drugs by capillary zone electrophoresis. Electrophoresis 2013; 34:2718-24. [DOI: 10.1002/elps.201300070] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2013] [Revised: 06/12/2013] [Accepted: 06/12/2013] [Indexed: 01/28/2023]
|
13
|
|
14
|
Allergy Diagnostics Using Magnetic Beads in a GRAVI TM- Cell Microfluidic Device. Chimia (Aarau) 2012. [DOI: 10.2533/chimia.2012.950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
15
|
Analysis of major milk whey proteins by immunoaffinity capillary electrophoresis coupled with MALDI-MS. Electrophoresis 2012; 33:2390-8. [DOI: 10.1002/elps.201200079] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
16
|
LEPA: From Proteomics to Energy Conversion. Chimia (Aarau) 2011; 65:672-6. [DOI: 10.2533/chimia.2011.672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
This review article summarizes the different fields of research at the Laboratoire d'Electrochimie Physique et Analytique at the Ecole Polytechnique Fédérale de Lausanne. The research areas covered include charge transfer reactions at soft interfaces, bio-analytical microchips
and electrophoretic methods, electrochemical ionization methods for mass spectrometry and Scanning Electrochemical Microscopy (SECM).
Collapse
|
17
|
Magnetic core shell nanoparticles trapping in a microdevice generating high magnetic gradient. LAB ON A CHIP 2011; 11:833-40. [PMID: 21253647 DOI: 10.1039/c0lc00510j] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Magnetic core shell nanoparticles (MCSNPs) 30 nm diameter with a magnetic weight of 10% are usually much too small to be trapped in microfluidic systems using classical external magnets. Here, a simple microchip for efficient MCSNPs trapping and release is presented. It comprises a bed of micrometric iron beads (6-8 μm diameter) packed in a microchannel against a physical restriction and presenting a low dead volume of 0.8 nL. These beads of high magnetic permeability are used to focus magnetic field lines from an external permanent magnet and generate local high magnetic gradients. The nanoparticles magnetic trap has been characterised both by numerical simulations and fluorescent MCSNPs imaging. Numerical simulations have been performed to map both the magnetic flux density and the magnetic force, and showed that MCSNPs are preferentially trapped at the iron bead magnetic poles where the magnetic force is increased by 3 orders of magnitude. The trapping efficiency was experimentally determined using fluorescent MCSNPs for different flow rates, different iron beads and permanent magnet positions. At a flow rate of 100 μL h(-1), the nanoparticles trapping/release can be achieved within 20 s with a preconcentration factor of 4000.
Collapse
|
18
|
Ring magnets for magnetic beads trapping in a capillary. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2011; 3:614-621. [PMID: 32938081 DOI: 10.1039/c0ay00596g] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
This paper introduces the concept of ring magnets for magnetic beads (MBs) trapping in a capillary. Such magnets enable an easy insertion of a capillary simply like a pearl on a string. With this system, high magnetic forces are obtained thanks to the proximity between the magnet and the capillary, giving the opportunity to work at higher flow rates than with classical setups using two magnets with their magnetization perpendicular to the capillary. Moreover, by alternating magnets and non-magnetic spacers either in attraction or repulsion configuration, it is possible to form a chain and as a consequence to adapt the number of magnets to the desired number of plugs, thus controlling the surface available for molecule binding. Magnetic force mapping was first carried out by numerical simulations for a single ring magnet. The usefulness of this concept was then demonstrated with the achievement of an immunoassay and an online preconcentration experiment. To study the formation of multiplugs, the magnetic force was first simulated for a chain of four magnets in repulsion. This force was then introduced into a convection-diffusion model to understand the influence of the flow velocity on their size and position. The numerical simulations were qualitatively corroborated by microscopic visualizations, carried out in a capillary placed between rectangular magnets having a magnetization parallel to the capillary, and quantitatively by bead capture efficiency experiments.
Collapse
|
19
|
Magnetic forces produced by rectangular permanent magnets in static microsystems. LAB ON A CHIP 2009; 9:2356-2363. [PMID: 19636467 DOI: 10.1039/b901865d] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Finite element numerical simulations were carried out in 2D geometries to map the magnetic field and force distribution produced by rectangular permanent magnets as a function of their size and position with respect to a microchannel. A single magnet, two magnets placed in attraction and in repulsion have been considered. The goal of this work is to show where magnetic beads are preferentially captured in a microchannel. These simulations were qualitatively corroborated, in one geometrical case, by microscopic visualizations of magnetic bead plug formation in a capillary. The results show that the number of plugs is configuration dependent with: in attraction, one plug in the middle of the magnets; in repulsion, two plugs near the edges of the magnets; and with a single magnet, a plug close to the center of the magnet. The geometry of the magnets (h and l are the height and length of the magnets respectively) and their relative spacing s has a significant impact on the magnetic flux density. Its value inside a magnet increases with the h/l ratio. Consequently, bar magnets produce larger and more uniform values than flat magnets. The l/s ratio also influences the magnetic force value in the microchannel, both increasing concomitantly for all the configurations. In addition, a zero force zone in the middle appears in the attraction configuration as the l/s ratio increases, while with a single magnet, the number of maxima and minima goes from one to two, producing two focusing zones instead of only one.
Collapse
|
20
|
|
21
|
|
22
|
Remarkable Tuning of the Photophysical Properties of Bifunctional Lanthanide tris(Dipicolinates) and its Consequence on the Design of Bioprobes. Inorg Chem 2008; 47:7802-12. [DOI: 10.1021/ic800842f] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|