1
|
Anatomical and radiological description of ligament insertions on the radial aspect of the scaphoid bone. HAND SURGERY & REHABILITATION 2022; 41:445-451. [PMID: 35660467 DOI: 10.1016/j.hansur.2022.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 05/15/2022] [Accepted: 05/24/2022] [Indexed: 06/15/2023]
Abstract
Anatomical studies on the radial side of the scaphoid mention inter-ligamentous connections, but without detailed description of their relations to one another. The purpose of this study was to provide an anatomical and radiological description of the ligamentous structure on the radial side of the scaphoid. High-field 3-Tesla 3D MRI scans of 7 cadaveric formaldehyde-fixed wrists were performed to assess the presence and location of each ligament. Dissection was performed in 10 wrists under microscopy on the radial side to assess the dimensions, anatomical variations and angles between ligaments in various wrist positions during in intracarpal pronation/supination, flexion/extension and ulnar/radial deviation. This study confirmed that the same ligament configuration was found on MRI and on dissection. The scaphotrapezial ligament, dorsal intercarpal ligament and radial collateral ligament fibers merge along the dorsal ridge of the scaphoid. The fibers of the radial collateral and radioscaphocapitate ligaments could be distinguished in only 4/10 specimens. Wrist position changes from intracarpal pronation to supination produced major changes in angle between the scaphotrapezial and dorsal intercarpal ligaments, while other position changes affected this angle only slightly. 3D MRI sequences allow these structures to be systematically analyzed in case of scapholunate instability. Further studies should be conducted to assess the biomechanical properties of these ligaments and the clinical consequences of isolated injury in this region.
Collapse
|
2
|
Diffusion-Weighted Imaging to Assess HPV-Positive versus HPV-Negative Oropharyngeal Squamous Cell Carcinoma: The Importance of b-Values. AJNR Am J Neuroradiol 2022; 43:905-912. [PMID: 35618419 DOI: 10.3174/ajnr.a7521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 03/26/2022] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Controversy exists as to whether ADC histograms are capable to distinguish human papillomavirus-positive (HPV+) from human papillomavirus-negative (HPV-) oropharyngeal squamous cell carcinoma. We investigated how the choice of b-values influences the capability of ADC histograms to distinguish between the two tumor types. MATERIALS AND METHODS Thirty-four consecutive patients with histologically proved primary oropharyngeal squamous cell carcinoma (11 HPV+ and 23 HPV-) underwent 3T MR imaging with a single-shot EPI DWI sequence with 6 b-values (0, 50, 100, 500, 750, 1000 s/mm2). Monoexponentially calculated perfusion-sensitive (including b=0 s/mm2) and perfusion-insensitive/true diffusion ADC maps (with b ≥ 100 s/mm2 as the lowest b-value) were generated using Matlab. The choice of b-values included 2 b-values (ADCb0-1000, ADCb100-1000, ADCb500-1000, ADCb750-1000) and 3-6 b-values (ADCb0-750-1000, ADCb0-500-750-1000, ADCb0-50-100-1000, ADCb0-50-100-750-1000, ADCb0-50-100-500-750-1000). Readers blinded to the HPV- status contoured all tumors. ROIs were then copied onto ADC maps, and their histograms were compared. RESULTS ADC histogram metrics in HPV+ and HPV- oropharyngeal squamous cell carcinoma changed significantly depending on the b-values. The mean ADC was lower, and skewness was higher in HPV+ than in HPV- oropharyngeal squamous cell carcinoma only for ADCb0-1000, ADCb0-750-1000, and ADCb0-500-750-1000 (P < .05), allowing distinction between the 2 tumor types. Kurtosis was significantly higher in HPV+ versus HPV- oropharyngeal squamous cell carcinoma for all b-value combinations except 2 perfusion-insensitive maps (ADCb500-1000 and ADCb750-1000). Among all b-value combinations, kurtosis on ADCb0-1000 had the highest diagnostic performance to distinguish HPV+ from HPV- oropharyngeal squamous cell carcinoma (area under the curve = 0.893; sensitivity = 100%, specificity = 82.6%). Acquiring multiple b-values for ADC calculation did not improve the distinction between HPV+ and HPV- oropharyngeal squamous cell carcinoma. CONCLUSIONS The choice of b-values significantly affects ADC histogram metrics in oropharyngeal squamous cell carcinoma. Distinguishing HPV+ from HPV- oropharyngeal squamous cell carcinoma is best possible on the ADCb0-1000 map.
Collapse
|
3
|
Relaxation time of brain tissue in the elderly assessed by synthetic MRI. Brain Behav 2022; 12:e2449. [PMID: 34862855 PMCID: PMC8785630 DOI: 10.1002/brb3.2449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 10/12/2021] [Accepted: 10/31/2021] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Synthetic MRI (SyMRI) is a quantitative technique that allows measurements of T1 and T2 relaxation times (RTs). Brain RT evolution across lifespan is well described for the younger population. The aim was to study RTs of brain parenchyma in a healthy geriatric population in order to define the normal value of structures in this group population. Normal values for geriatric population could help find biomarker for age-related brain disease. MATERIALS AND METHODS Fifty-four normal-functioning individuals (22 females, 32 males) with mean age of 83 years (range 56-98) underwent SyMRI. RT values in manually defined ROIs (centrum semiovale, middle cerebellar peduncles, thalamus, and insular cortex) and in segmented whole-brain components (brain parenchyma, gray matter, white matter, myelin, CSF, and stromal structures) were extracted from the SyMRI segmentation software. Patients' results were combined into the group age. Main ROI-based and whole-brain results were compared for the all dataset and for age group results as well. RESULTS For white matter, RTs between ROI-based analyses and whole-brain results for T2 and for T1 were statistically different and a trend of increasing T1 in centrum semiovale and cerebellar peduncle was observed. For gray matter, thalamic T1 was statistically different from insular T1. A difference was also found between left and right insula (p < .0001). T1 RTs of ROI-based and whole-brain-based analyses were statistically different (p < .0001). No significant difference in T1 and T2 was found between age groups on ROI-based analysis, but T1 in centrum semiovale and thalamus increased with age. No statistical difference between age groups was found for the various segmented volumes except for myelin between 65-74 years of age and the 95-105 years of age groups (p = .038). CONCLUSIONS SyMRI is a new tool that allows faster imaging and permits to obtain quantitative T1 and T2. By defining RT values of different brain components of normal-functioning elderly individuals, this technique may be used as a biomarker for clinical disorders like dementia.
Collapse
|
4
|
Comparing dynamic susceptibility contrast perfusion post-processing with different clinically available software among patients affected of a high-grade glioma. J Neuroradiol 2020; 49:412-420. [PMID: 33065197 DOI: 10.1016/j.neurad.2020.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 09/03/2020] [Accepted: 09/24/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND AND PURPOSE The main purpose of this retrospective study was to evaluate inter-software variability in patients affected of a high-grade glioma for the post-processing of dynamic susceptibility contrast (DSC1) perfusion imaging in MRI.2 MATERIALS AND METHODS: The included patients were either anaplastic astrocytoma (WHO3 grade III) or glioblastoma (WHO grade IV) located in the cerebral parenchyma. The postprocessing of 54 MRI-DSC imaging from 46 patients using both Intellispace© (Philips) and Olea© (Olea Medical) software was performed. The hemodynamic parameter studied was the normalised relative cerebral blood volume corrected for the T1 leakage effect (nrCBVc4). The inter-operator variabilities were also evaluated. RESULTS Regarding inter-software reproducibility, Cohen's Kappa from therapeutic follow-up obtained were 0.61, close to the recommended limit (0.60). Subgroups were created to complete the analysis and to evaluate the partial volume effect. Even if necrosis or vascular structures from regions of interest (ROI5) were avoided, results did not improve. ROI of a minimum area of 250 mm2 yielded a Cohen's Kappa of 0.65. The inter-operator reproducibility on Intellispace and Olea were 0.90 and 0.73 respectively, which is satisfactory. CONCLUSION The reproducibility between Intellispace and Olea was below recommended threshold in a clinical context. This discrepancy can be explained by the partial volume effect and the models used. ROI with an area of at least 250 mm2 improves this reproducibility and becomes acceptable.
Collapse
|
5
|
Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter. AJNR Am J Neuroradiol 2020; 41:488-494. [PMID: 32054620 DOI: 10.3174/ajnr.a6413] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2019] [Accepted: 12/23/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Flow diverter-induced hemodynamic change plays an important role in the mechanism of intracranial aneurysm occlusion. Our aim was to explore the relationship between aneurysm features and flow-diverter treatment of unruptured sidewall intracranial aneurysms. MATERIALS AND METHODS MR imaging, 4D phase-contrast, was prospectively performed before flow diverter implantation in each patient with unruptured intracranial aneurysm. Two postprocedure follow-ups were scheduled at 6 and 12 months. Responses were grouped according to whether the aneurysms were occluded or remnant. Preprocedural aneurysm geometries and ostium hemodynamics in 38 patients were compared between the 2 groups at 6 and 12 months. Receiver operating characteristic curve analyses were performed for significant geometric and hemodynamic continuous parameters. RESULTS After the 6-month assessment, 21 of 41 intracranial aneurysms were occluded, and 9 additional aneurysms were occluded at 12 months. Geometrically, the ostium maximum diameter was significantly larger in the remnant group at 6 and 12 months (both P < .001). Hemodynamically, the proximal inflow zone was more frequently observed in the remnant group at 6 months. Several preprocedural ostium hemodynamic parameters were significantly higher in the remnant group. As a prediction for occlusion, the areas under the curve of the ostium maximum diameter (for 6 and 12 months), systolic inflow rate ratio (for 6 months), and systolic inflow area (for 12 months) reached 0.843, 0.883, 0.855, and 0.860, respectively. CONCLUSIONS Intracranial aneurysms with a large ostium and strong ostium inflow may need a longer time for occlusion. Preprocedural 4D flow MR imaging can well illustrate ostium hemodynamics and characterize aneurysm treatment responses.
Collapse
|
6
|
|
7
|
How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study. AJNR Am J Neuroradiol 2019; 40:2117-2123. [PMID: 31727755 DOI: 10.3174/ajnr.a6312] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 09/20/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND AND PURPOSE Flow-diverter stents are widely used for the treatment of wide-neck intracranial aneurysms. Various parameters may influence intracranial aneurysm thrombosis, including the flow reduction induced by flow-diverter stent implantation, which is assumed to play a leading role. However, its actual impact remains unclear due to the lack of detailed intra-aneurysmal flow measurements. This study aimed to clarify this relationship by quantitatively measuring the intra-aneurysmal flow using 4D phase-contrast MR imaging. MATERIALS AND METHODS We acquired prospective pre- and post-stent implantation 4D phase-contrast MR imaging data of a consecutive series of 23 patients treated with flow-diverter stents. Velocity field data were combined with the intraprocedural 3D angiogram vessel geometries for precise intracranial aneurysm extraction and partial volume correction. Intra-aneurysmal hemodynamic modifications were compared with occlusion outcomes at 6 and 12 months. RESULTS The averaged velocities at systole were lower after flow-diverter stent implantation for all patients and ranged from 21.7 ± 7.1 cm/s before to 7.2 ± 2.9 cm/s after stent placement. The velocity reduction was more important for the group of patients with aneurysm thrombosis at 6 months (68.8%) and decreased gradually from 66.2% to 55% for 12-month thrombosis and no thrombosis, respectively (P = .08). CONCLUSIONS We propose an innovative approach to measure intracranial flow changes after flow-diverter stent implantation. We identified a trend between flow reduction and thrombosis outcome that brings a new insight into current understanding of the flow-diversion treatment response.
Collapse
|
8
|
Feasibility of a Synthetic MR Imaging Sequence for Spine Imaging. AJNR Am J Neuroradiol 2018; 39:1756-1763. [PMID: 30072367 DOI: 10.3174/ajnr.a5728] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 05/29/2018] [Indexed: 02/06/2023]
Abstract
BACKGROUND AND PURPOSE Synthetic MR imaging is a method that can produce multiple contrasts from a single sequence, as well as quantitative maps. Our aim was to determine the feasibility of a synthetic MR image for spine imaging. MATERIALS AND METHODS Thirty-eight patients with clinical indications of infectious, degenerative, and neoplastic disease underwent an MR imaging of the spine (11 cervical, 8 dorsal, and 19 lumbosacral MR imaging studies). The SyntAc sequence, with an acquisition time of 5 minutes 40 seconds, was added to the usual imaging protocol consisting of conventional sagittal T1 TSE, T2 TSE, and STIR TSE. RESULTS Synthetic T1-weighted, T2-weighted, and STIR images were of adequate quality, and the acquisition time was 53% less than with conventional MR imaging. The image quality was rated as "good" for both synthetic and conventional images. Interreader agreement concerning lesion conspicuity was good with a Cohen κ of 0.737. Artifacts consisting of white pixels/spike noise across contrast views, as well as flow artifacts, were more common in the synthetic sequences, particularly in synthetic STIR. There were no statistically significant differences between readers concerning the scores assigned for image quality or lesion conspicuity. CONCLUSIONS Our study shows that synthetic MR imaging is feasible in spine imaging and produces, in general, good image quality and diagnostic confidence. Furthermore, the non-negligible time savings and the ability to obtain quantitative measurements as well as to generate several contrasts with a single acquisition should promise a bright future for synthetic MR imaging in clinical routine.
Collapse
|
9
|
Neurovascular stent artifacts in 3D-TOF and 3D-PCMRI: Influence of stent design on flow measurement. Magn Reson Med 2018; 81:560-572. [DOI: 10.1002/mrm.27352] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Revised: 03/22/2018] [Accepted: 04/19/2018] [Indexed: 11/10/2022]
|
10
|
Advanced magnetic resonance imaging (MRI) techniques of the spine and spinal cord in children and adults. Insights Imaging 2018; 9:549-557. [PMID: 29858818 PMCID: PMC6108966 DOI: 10.1007/s13244-018-0626-1] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 03/19/2018] [Accepted: 04/05/2018] [Indexed: 12/14/2022] Open
Abstract
Abstract In this article, we illustrate the main advanced magnetic resonance imaging (MRI) techniques used for imaging of the spine and spinal cord in children and adults. This work focuses on daily clinical practice and aims to address the most common questions and needs of radiologists. We will also provide tips to solve common problems with which we were confronted. The main clinical indications for each MR technique, possible pitfalls and the challenges faced in spine imaging because of anatomical and physical constraints will be discussed. The major advanced MRI techniques dealt with in this article are CSF, (cerebrosopinal fluid) flow, diffusion, diffusion tensor imaging (DTI), MRA, dynamic contrast-enhanced T1-weighted perfusion, MR angiography, susceptibility-weighted imaging (SWI), functional imaging (fMRI) and spectroscopy. Teaching Points • DWI is essential to diagnose cord ischaemia in the acute stage. • MRA is useful to guide surgical planning or endovascular embolisation of AVMs. • Three Tesla is superior to 1.5 T for spine MR angiography and spectroscopy. • Advanced sequences should only be used together with conventional morphological sequences.
Collapse
|
11
|
Normal Values of Magnetic Relaxation Parameters of Spine Components with the Synthetic MRI Sequence. AJNR Am J Neuroradiol 2018; 39:788-795. [PMID: 29496723 DOI: 10.3174/ajnr.a5566] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 12/12/2017] [Indexed: 12/27/2022]
Abstract
BACKGROUND AND PURPOSE SyMRI is a technique developed to perform quantitative MR imaging. Our aim was to analyze its potential use for measuring relaxation times of normal components of the spine and to compare them with values found in the literature using relaxometry and other techniques. MATERIALS AND METHODS Thirty-two spine MR imaging studies (10 cervical, 5 dorsal, 17 lumbosacral) were included. A modified multiple-dynamic multiple-echo sequence was added and processed to obtain quantitative T1 (millisecond), T2 (millisecond), and proton density (percentage units [pu]) maps for each patient. An ROI was placed on representative areas for CSF, spinal cord, intervertebral discs, and vertebral bodies, to measure their relaxation. RESULTS Relaxation time means are reported for CSF (T1 = 4273.4 ms; T2 = 1577.6 ms; proton density = 107.5 pu), spinal cord (T1 = 780.2 ms; T2 = 101.6 ms; proton density = 58.7 pu), normal disc (T1 = 1164.9 ms; T2 = 101.9 ms; proton density = 78.9 pu), intermediately hydrated disc (T1 = 723 ms; T2 = 66.8 ms; proton density = 60.8 pu), desiccated disc (T1 = 554.4 ms; T2 = 55.6 ms; proton density = 47.6 ms), and vertebral body (T1 = 515.3 ms; T2 = 100.8 ms; proton density = 91.1 pu). Comparisons among the mean T1, T2, and proton density values showed significant differences between different spinal levels (cervical, dorsal, lumbar, and sacral) for CSF (proton density), spinal cord (T2 and proton density), normal disc (T1, T2, and proton density), and vertebral bodies (T1 and proton density). Significant differences were found among mean T1, T2, and proton density values of normal, intermediately hydrated, and desiccated discs. CONCLUSIONS Measurements can be easily obtained on SyMRI and correlated with previously published values obtained using conventional relaxometry techniques.
Collapse
|
12
|
Vessel calibre and flow splitting relationships at the internal carotid artery terminal bifurcation. Physiol Meas 2017; 38:2044-2057. [DOI: 10.1088/1361-6579/aa92bf] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels. Magn Reson Med 2017; 79:129-140. [PMID: 28244132 DOI: 10.1002/mrm.26637] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Revised: 01/19/2017] [Accepted: 01/19/2017] [Indexed: 11/11/2022]
Abstract
PURPOSE Recent advances in 3D-PCMRI (phase contrast MRI) sequences allow for measuring the complex hemodynamics in cerebral arteries. However, the small size of these vessels vs spatial resolution can lead to non-negligible partial volume artifacts, which must be taken into account when computing blood flow rates. For this purpose, we combined the velocity information provided by 3D-PCMRI with vessel geometry measured with 3DTOF (time of flight MRI) or 3DRA (3D rotational angiography) to correct the partial volume effects in flow rate assessments. METHODS The proposed methodology was first tested in vitro on cylindrical and patient specific vessels subject to fully controlled pulsatile flows. Both 2D- and 3D-PCMRI measurements using various spatial resolutions ranging from 20 to 1.3 voxels per vessel diameter were analyzed and compared with flowmeter baseline. Second, 3DTOF, 2D- and 3D-PCMRI measurements were performed in vivo on 35 patients harboring internal carotid artery (ICA) aneurysms indicated for endovascular treatments requiring 3DRA imaging. RESULTS The in vitro 2D- and 3D-PCMRI mean flow rates assessed with partial volume correction showed very low sensitivity to the acquisition resolution above ≈2 voxels per vessel diameter while uncorrected flow rates deviated critically when decreasing the spatial resolution. 3D-PCMRI flow rates measured in vivo in ICA agreed very well with 2D-PCMRI data and a good flow conservation was observed at the C7 bifurcation. Globally, partial volume correction led to 10-15% lower flow rates than uncorrected values as those reported in most of the published studies on intracranial flows. CONCLUSION Partial volume correction may improve the accuracy of PCMRI flow rate measurements especially in small vessels such as intracranial arteries. Magn Reson Med 79:129-140, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
|
14
|
Abstract
Breast cancer is an international public health concern in which an optimal treatment plan requires a precise staging. Both MRI and PET imaging techniques have made significant progress in the last decades with constant improvements that made both modalities clinically relevant in several stages of breast cancer management and follow-up. On one hand, specific breast MRI permits high diagnostic accuracy for local tumor staging, and whole-body MRI can also be of great use in distant staging, eventually accompanied by organ-specific MRI sequences. Moreover, many different MRI sequences can be performed, including functional MRI, letting us foresee important improvements in breast cancer characterization in the future. On the contrary, (18)F-FDG-PET has a high diagnostic performance for the detection of distant metastases, and several other tracers currently under development may profoundly affect breast cancer management in the future with better determination of different types of breast cancers allowing personalized treatments. As a consequence PET/MR is a promising emerging technology, and it is foreseeable that in cases where both PET and MRI data are needed, a hybrid acquisition is justified when available. However, at this stage of deployment of such hybrid scanners in a clinical setting, more data are needed to demonstrate their added value beyond just patient comfort of having to undergo a single examination instead of two, and the higher confidence of diagnostic interpretation of these co-registered images. Optimized imaging protocols are still being developed and are prone to provide more efficient hybrid protocols with a potential improvement in diagnostic accuracy. More convincing studies with larger number of patients as well as cost-effectiveness studies are needed. This article provides insights into the current state-of-the-art of PET/MR in patients with breast cancer and gives an outlook on future developments of both imaging techniques and potential applications in the future.
Collapse
|
15
|
Diffusion in prostate cancer detection on a 3T scanner: How many b-values are needed? J Magn Reson Imaging 2016; 44:601-9. [DOI: 10.1002/jmri.25206] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Accepted: 02/09/2016] [Indexed: 12/30/2022] Open
|
16
|
Sequential whole-body PET/MR scanner: concept, clinical use, and optimisation after two years in the clinic. The manufacturer’s perspective. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2012; 26:5-23. [DOI: 10.1007/s10334-012-0330-y] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 07/10/2012] [Accepted: 07/11/2012] [Indexed: 01/08/2023]
|
17
|
Manganese kinetics demonstrated double contrast in acute but not in chronic infarction in a mouse model of myocardial occlusion reperfusion. NMR IN BIOMEDICINE 2012; 25:489-497. [PMID: 21796712 DOI: 10.1002/nbm.1759] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2011] [Revised: 04/11/2011] [Accepted: 05/10/2011] [Indexed: 05/31/2023]
Abstract
Manganese (Mn(2+)) is considered as a specific MRI contrast agent that enters viable cardiomyocytes through calcium pathways. Compared to extracellular gadolinium based contrast agents, it has the potential to assess cell viability. To date, only information from the washout phase after recirculation has been used for the detection and characterization of myocardial infarct. This study showed for the first time that in a mouse model of coronary occlusion-reperfusion, Mn(2+) wash-in kinetics are different at 24 h after surgery (acute infarction) than at eight days after surgery (chronic infarction). A fast but transient entry of Mn(2+) into the acute infarct area led to a double contrast between infarct and remote areas, whereas entry of Mn(2+) into the chronic infarct area remained reduced compared to remote regions during both wash-in and washout phases. The main hypothesis is that extracellular space is largely enhanced in acute infarction due to cell membrane rupture and interstitial edema, whereas scar tissue is densely composed of collagen fibers that reduce the distribution volume of free Mn(2+) ions. In addition to its ability to accurately depict the infarct area during the redistribution phase, Mn(2+) is also able to discriminate acute versus chronic injury by the observation of double-contrast kinetics in a mouse model of ischemia reperfusion.
Collapse
|
18
|
Head-to-head comparison of eight late gadolinium-enhanced cardiac MR (LGE CMR) sequences at 1.5 tesla: from bench to bedside. J Magn Reson Imaging 2011; 34:1374-87. [PMID: 21972032 DOI: 10.1002/jmri.22783] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2011] [Accepted: 07/28/2011] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To compare-theoretically and experimentally-clinically available two-dimensional/three-dimensional (2D/3D), breathhold and non-breathhold, inversion-recovery (IR) gradient-echo (GRE) sequences used to differentiate between nonviable injured and normal myocardium with late gadolinium-enhanced techniques (IR-GRE2D sequence is used as a reference), and to evaluate their respective clinical benefit. MATERIALS AND METHODS Six breathhold (2D-IR-GRE, 3D-IR-GRE, balanced steady-state free precession 2D-IR-bSSFP and 3D-IR-bSSFP, phase-sensitive 2D-PSIR-GRE, and 2D-PSIR-bSSFP) and two non-breathhold late gadolinium-enhanced techniques (single-shot 2D-ssbSSFP and 2D-PSIR-ssbSSFP) were consecutively performed in 32 coronary artery disease patients with chronic myocardial infarction. Qualitative assessment and manual planimetry were performed by two independent observers. Quantitative assessment was based on percentage signal intensity elevation between injured and normal myocardium and contrast-to-noise ratio. Theoretical simulations were compared with experimental measurements performed on phantoms with various concentrations of gadolinium. RESULTS The 3D-IR-GRE image quality appeared better than the other 2D and 3D sequences, showing better delineation of complex nontransmural lesions, with significantly higher percentage signal intensity and contrast-to-noise ratio. PSIR techniques appeared more limited in differentiating sub-endocardial lesions and intracavity blood pool, but in all other cases were comparable to the other techniques. Single-shot PSIR-ssbSSFP appeared to be a valuable alternative technique when breathhold cannot be achieved. CONCLUSION We recommend 3D-IR-GRE as the method of choice for late gadolinium-enhanced cardiac magnetic resonance imaging in clinical practice.
Collapse
|
19
|
Myocardial infarction quantification with Manganese-Enhanced MRI (MEMRI) in mice using a 3T clinical scanner. NMR IN BIOMEDICINE 2010; 23:503-513. [PMID: 20175138 DOI: 10.1002/nbm.1489] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Manganese (Mn(2+)) was recognized early as an efficient intracellular MR contrast agent to assess cardiomyocyte viability. It had previously been used for the assessment of myocardial infarction in various animal models from pig to mouse. However, whether Manganese-Enhanced MRI (MEMRI) is also able to assess infarction in the acute phase of a coronary occlusion reperfusion model in mice has not yet been demonstrated. This model is of particular interest as it is closer to the situation encountered in the clinical setting. This study aimed to measure infarction volume taking TTC staining as a gold standard, as well as global and regional function before and after Mn(2+) injection using a clinical 3T scanner. The first step of this study was to perform a dose-response curve in order to optimize the injection protocol. Infarction volume measured with MEMRI was strongly correlated to TTC staining. Ejection fraction (EF) and percent wall thickening measurements allowed evaluation of global and regional function. While EF must be measured before Mn(2+) injection to avoid bias introduced by the reduction of contrast in cine images, percent wall thickening can be measured either before or after Mn(2+) injection and depicts accurately infarct related contraction deficit. This study is the first step for further longitudinal studies of cardiac disease in mice on a clinical 3T scanner, a widely available platform.
Collapse
|
20
|
Spiral demystified. Magn Reson Imaging 2010; 28:862-81. [PMID: 20409660 DOI: 10.1016/j.mri.2010.03.036] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2009] [Revised: 02/24/2010] [Accepted: 03/05/2010] [Indexed: 10/19/2022]
Abstract
Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging such as cardiac imaging and functional brain imaging. However, these advantages are counterbalanced by practical difficulties that render spiral imaging quite challenging. Firstly, the design of gradient waveforms and its hardware requires specific attention. Secondly, the reconstruction of such data is no longer straightforward because k-space samples are no longer aligned on a Cartesian grid. Thirdly, to take advantage of parallel imaging techniques, the common generalized autocalibrating partially parallel acquisitions (GRAPPA) or sensitivity encoding (SENSE) algorithms need to be extended. Finally, and most notably, spiral images are prone to particular artifacts such as blurring due to gradient deviations and off-resonance effects caused by B(0) inhomogeneity and concomitant gradient fields. In this article, various difficulties that spiral imaging brings along, and the solutions, which have been developed and proposed in literature, will be reviewed in detail.
Collapse
|