1
|
1H Spin-Lattice Relaxation Processes in Solutions of H 2N-Fe 3O 4 Nanoparticles: Insights from NMR Relaxometry. J Phys Chem B 2024; 128:2773-2781. [PMID: 38461422 DOI: 10.1021/acs.jpcb.3c07617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
1H spin-lattice relaxation experiments have been performed for water and glycerol/water solutions of H2N-Fe3O4 superparamagnetic nanoparticles (NPs) of about 7 nm diameter. The experiments encompass a broad frequency range covering 3 orders of magnitude, from 10 kHz to 10 MHz (referring to 1H resonance frequency), and have been performed in the temperature range from 298 to 313 K, varying the concentration of the superparamagnetic species. This extensive dataset has been used for twofold purposes. The first one is to serve as a challenge for thorough tests of theoretical models describing nuclear relaxation in solutions of superparamagnetic NPs, depending on their magnetic properties and dynamics of the solvent molecules. The challenge is posed by the wish to reproduce the data in a broad range of magnetic fields (not only at high fields) and by the need to explain the differences in the relaxation scenarios for water and glycerol/water solutions by varying only the solvent parameters. The second purpose is to get insights into the magnetic properties (electronic relaxation properties) of the nanoparticles due to their high applicational potential.
Collapse
|
2
|
X-ray-Sensitive Doped CaF 2-Based MRI Contrast Agents for Local Radiation Dose Measurement. ACS APPLIED MATERIALS & INTERFACES 2024; 16:13453-13465. [PMID: 38445594 DOI: 10.1021/acsami.3c16336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/07/2024]
Abstract
Ionizing radiation has become widely used in medicine, with application in diagnostic techniques, such as computed tomography (CT) and radiation therapy (RT), where X-rays are used to diagnose and treat tumors. The X-rays used in CT and, in particular, in RT can have harmful side effects; hence, an accurate determination of the delivered radiation dose is of utmost importance to minimize any damage to healthy tissues. For this, medical specialists mostly rely on theoretical predictions of the delivered dose or external measurements of the dose. To extend the practical use of ionizing radiation-based medical techniques, such as magnetic resonance imaging (MRI)-guided RT, a more precise measurement of the internal radiation dose internally is required. In this work, a novel approach is presented to measure dose in liquids for potential future in vivo applications. The strategy relies on MRI contrast agents (CAs) that provide a dose-sensitive signal. The demonstrated materials are (citrate-capped) CaF2 nanoparticles (NPs) doped with Eu3+ or Fe2+/Fe3+ ions. Free electrons generated by ionizing radiation allow the reduction of Eu3+, which produces a very small contrast in MRI, to Eu2+, which induces a strong contrast. Oxidative species generated by high-energy X-rays can be measured indirectly using Fe2+ because it oxidizes to Fe3+, increasing the contrast in MRI. Notably, in the results, a strong increase in the proton relaxation rates is observed for the Eu3+-doped NPs at 40 kV. At 6 MV, a significant increase in proton relaxation rates is observed using CaF2 NPs doped with Fe2+/Fe3+ after irradiation. The presented concept shows great promise for use in the clinic to measure in vivo local ionizing radiation dose, as these CAs can be intravenously injected in a saline solution.
Collapse
|
3
|
Fe 3O 4 Magnetic Nanoparticles Obtained by the Novel Aerosol-Based Technique for Theranostic Applications. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6483. [PMID: 37834621 PMCID: PMC10573611 DOI: 10.3390/ma16196483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/20/2023] [Accepted: 09/25/2023] [Indexed: 10/15/2023]
Abstract
This work is aimed at presenting a novel aerosol-based technique for the synthesis of magnetite nanoparticles (Fe3O4 NPs) and to assess the potential medical application of their dispersions after being coated with TEA-oleate. Refinement of the processing conditions led to the formation of monodispersed NPs with average sizes of ∼5-6 nm and narrow size distribution (FWHM of ∼3 nm). The NPs were coated with Triethanolammonium oleate (TEA-oleate) to stabilize them in water dispersion. This allowed obtaining the dispersion, which does not sediment for months, although TEM and DLS studies have shown the formation of small agglomerates of NPs. The different behaviors of cancer and normal cell lines in contact with NPs indicated the diverse mechanisms of their interactions with Fe3O4 NPs. Furthermore, the studies allowed assessment of the prospective theranostic application of magnetite NPs obtained using the aerosol-based technique, particularly magnetic hyperthermia and magnetic resonance imaging (MRI).
Collapse
|
4
|
Contrast Enhancement in MRI Using Combined Double Action Contrast Agents and Image Post-Processing in the Breast Cancer Model. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3096. [PMID: 37109931 PMCID: PMC10142138 DOI: 10.3390/ma16083096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/02/2023] [Accepted: 04/11/2023] [Indexed: 06/19/2023]
Abstract
Gd- and Fe-based contrast agents reduce T1 and T2 relaxation times, respectively, are frequently used in MRI, providing improved cancer detection. Recently, contrast agents changing both T1/T2 times, based on core/shell nanoparticles, have been introduced. Although advantages of the T1/T2 agents were shown, MR image contrast of cancerous versus normal adjacent tissue induced by these agents has not yet been analyzed in detail as authors considered changes in cancer MR signal or signal-to-noise ratio after contrast injection rather than changes in signal differences between cancer and normal adjacent tissue. Furthermore, the potential advantages of T1/T2 contrast agents using image manipulation such as subtraction or addition have not been yet discussed in detail. Therefore, we performed theoretical calculations of MR signal in a tumor model using T1-weighted, T2-weighted, and combined images for T1-, T2-, and T1/T2-targeted contrast agents. The results from the tumor model are followed by in vivo experiments using core/shell NaDyF4/NaGdF4 nanoparticles as T1/T2 non-targeted contrast agent in the animal model of triple negative breast cancer. The results show that subtraction of T2-weighted from T1-weighted MR images provides additional increase in the tumor contrast: over two-fold in the tumor model and 12% in the in vivo experiment.
Collapse
|
5
|
A truncated twisted solenoid RF phase gradient transmit coil for TRASE MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 347:107361. [PMID: 36599255 DOI: 10.1016/j.jmr.2022.107361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 11/19/2022] [Accepted: 12/18/2022] [Indexed: 06/17/2023]
Abstract
Transmit array spatial encoding (TRASE) is an MR imaging technique that achieves k-space encoding through the use of phase gradients in the RF transmit field. Without requiring B0 gradient fields, TRASE MRI can be performed using significantly cheaper bi-planar permanent magnets or Halbach arrays. For TRASE encoding with these magnets, the twisted solenoid has been demonstrated as the most efficient RF transmit coil; however, this specific geometry results in a long coil with a relatively short imaging volume. We introduce a new truncated design to increase the usable imaging volume relative to the coil length. Based on simulations of optimal parameters, a 200 mm long, 100 mm inner diameter coil pair was constructed with an imaging volume 100 mm in length and 80 mm in diameter. The coil pair was tested using an un-shimmed 2.84 MHz Halbach array. Results indicate the truncated design can create a similar imaging volume and quality to the untruncated version whilst significantly reducing the length of the coil by as much as a half.
Collapse
|
6
|
Target-Specific Magnetic Resonance Imaging of Human Prostate Adenocarcinoma Using NaDyF 4-NaGdF 4 Core-Shell Nanoparticles. ACS APPLIED MATERIALS & INTERFACES 2021; 13:24345-24355. [PMID: 34024098 DOI: 10.1021/acsami.0c19273] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
We illustrate the development of NaDyF4-NaGdF4 core-shell nanoparticles (NPs) for targeting prostate cancer cells using a preclinical 9.4 T magnetic resonance imaging (MRI) of live animals. The NPs composed of paramagnetic Dy3+ and Gd3+ (T2- and T1-contrast agents, respectively) demonstrate proton relaxivities of r1 = 20.2 mM-1 s-1 and r2 = 32.3 mM-1 s-1 at clinical 3 T and r1 = 9.4 mM-1 s-1 and r2 = 144.7 mM-1 s-1 at preclinical 9.4 T. The corresponding relaxivity values per NP are r1 = 19.4 × 105 mMNP-1 s-1 and r2 = 33.0 × 105 mMNP-1 s-1 at 3 T and r1 = 9.0 × 105 mMNP-1 s-1 and r2 = 147.0 × 105 mMNP-1 s-1 at 9.4 T. In vivo active targeting of human prostate tumors grown in nude mice revealed docking of anti-prostate-specific membrane antigen (PSMA) antibody-tagged NPs at tumor sites post-24 h of their intravenous injection. On the other hand, in vivo passive targeting showed preferential accumulation of NPs at tumor sites only within 2 h of their injection, ascribed to the enhanced permeation and retention effect of the tumor. A biodistribution study employing the harvested organs of mice, post-24 h injection of NPs, quantified active targeting as nearly twice as efficient as passive targeting. These outcomes provide potential opportunities for noninvasive diagnosis using NaDyF4-NaGdF4 core-shell NPs for target-specific MRI.
Collapse
|
7
|
Simple compensation method for improved half-pulse excitation profile with rephasing gradient. Magn Reson Med 2020; 84:1796-1805. [PMID: 32129544 DOI: 10.1002/mrm.28233] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 01/14/2020] [Accepted: 02/07/2020] [Indexed: 12/21/2022]
Abstract
PURPOSE To improve the slice profile quality obtained by RF half-pulse excitation for 2D-UTE applications. METHODS The overall first-order and zero-order phase errors along the slice-selection direction were obtained with the help of an optimization task to minimize the out-of-slice signal contamination from the calibration 1-dimenisonal (1D) profile data. The time-phase-error evolution was approximated from the k-space readout data, which were acquired primarily for correction of the readout trajectories during data regridding to the rectilinear grids. The correction of the slice profile was achieved by rephasing gradient pulses applied immediately after the end of excitation. The total prescan calibration typically took less than 2 minutes. RESULTS The improved image quality using the proposed calibration method was demonstrated both on phantoms and on ankle images obtained from healthy volunteers. It was demonstrated that calibration can be performed either as a separate water phantom measurement or directly as a prescan procedure. CONCLUSION The slice-profile distortion from the half-pulse excitation could substantially affect the overall fidelity of 2D-UTE images. The presented experiments proved that the image quality could be substantially increased by application of the proposed slice-correction method.
Collapse
|
8
|
Bifunctional Pyrrolidin-2-one Terminated Manganese Oxide Nanoparticles for Combined Magnetic Resonance and Fluorescence Imaging. ACS APPLIED MATERIALS & INTERFACES 2019; 11:13069-13078. [PMID: 30883086 DOI: 10.1021/acsami.8b21762] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Multimodal probes are an asset for simplified, improved medical imaging. In particular, fluorescence and magnetic resonance imaging (MRI) are sought-after combined capabilities. Here, we show that pyrrolidin-2-one-capped manganese oxide nanoparticles (MnOpyrr NPs) combine MRI with fluorescence microscopy to function as efficient bifunctional bio-nanoprobes. We employ a one-pot synthesis for ca. 10 nm MnO NPs, wherein manganese(II) 2,4-pentadionate is thermally decomposed using pyrrolidin-2-one as a solvent and capping ligand. The MnOpyrr NPs are soluble in water without any further postsynthetic modifications. The r1 relaxivity and r2 /r1 ratio indicate that these NPs are potential T1 MRI contrast agents at clinical (3 T) and ultrahigh (9.4 T) magnetic fields. Serendipitously, the as-prepared NPs are photoluminescent. The unexpected luminescence is ascribed to the modification of the pyrrolidin-2-one during the thermal treatment. MnOpyrr NPs are successfully used to enable fluorescence microscopy of HeLa cells, demonstrating bifunctional imaging capabilities. A low cytotoxic response in two distinct cell types (HeLa, HepG2) supports the suitability of MnOpyrr NPs for biological imaging applications.
Collapse
|
9
|
Challenges in developing a magnetic resonance-compatible haptic hand-controller for neurosurgical training. Proc Inst Mech Eng H 2018; 232:954411918806934. [PMID: 30355029 DOI: 10.1177/0954411918806934] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
A haptic device is an actuated human-machine interface utilized by an operator to dynamically interact with a remote environment. This interaction could be virtual (virtual reality) or physical such as using a robotic arm. To date, different mechanisms have been considered to actuate the haptic device to reflect force feedback from the remote environment. In a low-force environment or limited working envelope, the control of some actuation mechanisms such as hydraulic and pneumatic may be problematic. In the development of a haptic device, challenges include limited space, high accuracy or resolution, limitations in kinematic and dynamic solutions, points of singularity, dexterity as well as control system development/design. Furthermore, the haptic interface designed to operate in a magnetic resonance imaging environment adds additional challenges related to electromagnetic interference, static/variable magnetic fields, and the use of magnetic resonance-compatible materials. Such a device would allow functional magnetic resonance imaging to obtain information on the subject's brain activity while performing a task. When used for surgical trainees, functional magnetic resonance imaging could provide an assessment of surgical skills. In this application, the trainee, located supine within the magnet bore while observing the task environment on a graphical user interface, uses a low-force magnetic resonance-compatible haptic device to perform virtual surgical tasks in a limited space. In the quest to develop such a device, this review reports the multiple challenges faced and their potential solutions. The review also investigates efforts toward prototyping such devices and classifies the main components of a magnetic resonance-compatible device including actuation and sensory systems and materials used.
Collapse
|
10
|
Influence of k-space trajectory corrections on proton density mapping with ultrashort echo time imaging: Application for imaging of short T2 components in white matter. Magn Reson Imaging 2018; 51:87-95. [PMID: 29729437 DOI: 10.1016/j.mri.2018.04.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 04/30/2018] [Accepted: 04/30/2018] [Indexed: 12/19/2022]
Abstract
PURPOSE To evaluate the impact of MR gradient system imperfections and limitations for the quantitative mapping of short T2* signals performed by ultrashort echo time (UTE) acquisition approach. MATERIALS AND METHODS The measurement of short T2* signals from a phantom and a healthy volunteer study (8 subjects of average age 28 ± 4 years) were performed on a 3T scanner. The characteristics of the gradient system were obtained using calibration method performed directly on the measured subject or phantom. This information was used to calculate the actual sampling trajectory with the help of a parametric eddy current model. The actual sample positions were used to reconstruct corrected images and compared with uncorrected data. RESULTS Comparison of both approaches, i.e., without and with correction of k-space sampling trajectories revealed substantial improvement when correction was applied. The phantom experiments demonstrate substantial in-plane signal intensity variations for uncorrected sampling trajectories. In the case of the volunteer study, this led to significant differences in relative proton density (RPD) estimation between the uncorrected and corrected data (P = 0.0117 by Wilcoxon matched-pairs test) and provides for about ~15% higher values for short T2* components of white matter (WM) in the case of uncorrected images. CONCLUSION The imperfection of the applied gradients could induce errors in k-space data sampling which further propagates into the fidelity of the UTE images and jeopardizes precision of quantification. However, the study proved that measurement of gradient errors together with correction of sample positions can contribute to increased accuracy and unbiased characterization of short T2* signals.
Collapse
|
11
|
Correction to: LyP-1 Conjugated Nanoparticles for Magnetic Resonance Imaging of Triple Negative Breast Cancer. Mol Imaging Biol 2018; 20:436. [PMID: 29556946 DOI: 10.1007/s11307-018-1189-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
This article was updated to correct the spelling of B. Gino Fallone's name; it is correct as displayed above. Correction to: Mol Imaging Biol (2017). DOI: https://doi.org/10.1007/s11307-017-1140-4.
Collapse
|
12
|
LyP-1 Conjugated Nanoparticles for Magnetic Resonance Imaging of Triple Negative Breast Cancer. Mol Imaging Biol 2017; 20:428-435. [DOI: 10.1007/s11307-017-1140-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
13
|
Synthesis, characterization, and evaluation of PEGylated first-row transition metal ferrite nanoparticles as T2contrast agents for high-field MRI. RSC Adv 2017. [DOI: 10.1039/c7ra05495e] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
PEGylated MFe2O4(M = Mn through Zn) spinel ferrite preparedviaa novel one-pot synthesis were evaluated for high-field (B0= 9.4 T) magnetic resonance imaging.
Collapse
|
14
|
Site-specific conjugation of the quencher on peptide's N-terminal for the synthesis of a targeted non-spreading activatable optical probe. J Pept Sci 2016; 22:415-20. [DOI: 10.1002/psc.2884] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2015] [Revised: 03/14/2016] [Accepted: 03/16/2016] [Indexed: 11/06/2022]
|
15
|
Evaluation of blood-brain barrier-stealth nanocomposites for in situ glioblastoma theranostics applications. NANOSCALE 2016; 8:7866-7870. [PMID: 27035391 DOI: 10.1039/c6nr00280c] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The blood-brain barrier (BBB) is a physiological structure of the blood vessels in the brain. The BBB efficiently traps most therapeutic drugs in the blood vessels and stops them from entering the brain tissue, resulting in a decreased therapeutic efficiency. In this study, we developed BBB-stealth nanocomposites composed of iron oxide (Fe3O4) nanoparticles (NPs) as a safe nanocarrier for glioblastoma therapy. We showed the antitumor activity of Dox/alg-Fe3O4 NPs using in vitro and in vivo tests. We demonstrated that G23-alg-Fe3O4 NPs crossed the BBB and entered the brain. In situ glioblastoma tumor-bearing mice were used to successfully evaluate the antitumor activity of G23-Dox/alg-Fe3O4 NPs. Magnetic resonance imaging (MRI) and bioluminescence imaging (BLI) confirmed the BBB crossing. The BBB-stealth nanocomposites show great potential for a proof-of-concept clinical trial as a theranostics platform for human brain tumor therapy.
Collapse
|
16
|
HyperCEST detection of cucurbit[6]uril in whole blood using an ultrashort saturation Pre-pulse train. CONTRAST MEDIA & MOLECULAR IMAGING 2016; 11:285-90. [DOI: 10.1002/cmmi.1690] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Revised: 02/02/2016] [Accepted: 02/14/2016] [Indexed: 01/23/2023]
|
17
|
NI-08 * OPTIMIZATION OF MOLECULAR MR IMAGING OF GLIOMA. Neuro Oncol 2014. [DOI: 10.1093/neuonc/nou264.8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
18
|
|
19
|
White and gray matter contrast enhancement in MR images of the mouse brain in vivo using IR UTE with a cryo-coil at 9.4T. J Neurosci Methods 2014; 232:30-5. [DOI: 10.1016/j.jneumeth.2014.04.019] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 04/12/2014] [Accepted: 04/14/2014] [Indexed: 11/30/2022]
|
20
|
Tractography of Meyer's Loop asymmetries. Epilepsy Res 2014; 108:872-82. [PMID: 24725809 DOI: 10.1016/j.eplepsyres.2014.03.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Revised: 01/24/2014] [Accepted: 03/16/2014] [Indexed: 11/20/2022]
|
21
|
Abstract
Brain metabolism is thought to be maintained by neuronal-glial metabolic coupling. Glia take up glutamate from the synaptic cleft for conversion into glutamine, triggering glial glycolysis and lactate production. This lactate is shuttled into neurons and further metabolized. The origin and role of lactate in severe traumatic brain injury (TBI) remains controversial. Using a modified weight drop model of severe TBI and magnetic resonance (MR) spectroscopy with infusion of (13)C-labeled glucose, lactate, and acetate, the present study investigated the possibility that neuronal-glial metabolism is uncoupled following severe TBI. Histopathology of the model showed severe brain injury with subarachnoid and hemorrhage together with glial cell activation and positive staining for Tau at 90 min post-trauma. High resolution MR spectroscopy of brain metabolites revealed significant labeling of lactate at C-3 and C-2 irrespective of the infused substrates. Increased (13)C-labeled lactate in all study groups in the absence of ischemia implied activated astrocytic glycolysis and production of lactate with failure of neuronal uptake (i.e. a loss of glial sensing for glutamate). The early increase in extracellular lactate in severe TBI with the injured neurons rendered unable to pick it up probably contributes to a rapid progression toward irreversible injury and pan-necrosis. Hence, a method to detect and scavenge the excess extracellular lactate on site or early following severe TBI may be a potential primary therapeutic measure.
Collapse
|
22
|
Molecular susceptibility weighted imaging of the glioma rim in a mouse model. J Neurosci Methods 2014; 226:132-138. [DOI: 10.1016/j.jneumeth.2014.01.034] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 01/09/2014] [Accepted: 01/31/2014] [Indexed: 11/15/2022]
|
23
|
Symmetry of the fornix using diffusion tensor imaging. J Magn Reson Imaging 2013; 40:929-36. [PMID: 24923980 DOI: 10.1002/jmri.24424] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2013] [Accepted: 08/30/2013] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To: 1) Present fornix tractography in its entirety for 20 healthy individuals to assess variability. 2) Provide individual and groupwise whole tract diffusion parameter symmetry assessments prior to clinical application. 3) Compare whole tract diffusion parameter assessments with tract-based spatial statistics (TBSS). MATERIALS AND METHODS Diffusion tensor imaging (DTI) data were acquired on a 3T Siemens magnetic resonance imaging (MRI) system using a single-shot spin echo planar imaging (EPI) sequence. Individual fornix tractography was conducted and whole tract diffusion parameter symmetries assessed. Whole tract results were compared with asymmetry contrasts conducted with voxelwise statistical analysis of diffusion parameters using TBSS. RESULTS The fornix tract could be visualized in its entirety including the columns, body, crura, and fimbria. Contrary to the crus and body, there were some tractography inconsistencies of the columns and fimbria across subjects. Although whole tract diffusion parameter asymmetries were nonsignificant, fractional anisotropy (FA) values bordered on statistical significance (P = 0.052). Using TBSS, significant FA asymmetries were identified (P ≤ 0.01, corrected). CONCLUSION The findings demonstrate consistency of fornix tractography as well as some variability in the columns and fimbria. While parametric assessment demonstrates diffusion parameter symmetry, permutation-based TBSS analysis reveals significant FA asymmetries in the crura and fimbriae.
Collapse
|
24
|
High-resolution MRI encoding using radiofrequency phase gradients. NMR IN BIOMEDICINE 2013; 26:1602-1607. [PMID: 24019215 DOI: 10.1002/nbm.3023] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2013] [Revised: 06/28/2013] [Accepted: 08/10/2013] [Indexed: 06/02/2023]
Abstract
Although MRI offers highly diagnostic medical imagery, patient access to this modality worldwide is very limited when compared with X-ray or ultrasound. One reason for this is the expense and complexity of the equipment used to generate the switched magnetic fields necessary for MRI encoding. These field gradients are also responsible for intense acoustic noise and have the potential to induce nerve stimulation. We present results with a new MRI encoding principle which operates entirely without the use of conventional B0 field gradients. This new approach--'Transmit Array Spatial Encoding' (TRASE)--uses only the resonant radiofrequency (RF) field to produce Fourier spatial encoding equivalent to conventional MRI. k-space traversal (image encoding) is achieved by spin refocusing with phase gradient transmit fields in spin echo trains. A transmit coil array, driven by just a single transmitter channel, was constructed to produce four phase gradient fields, which allows the encoding of two orthogonal spatial axes. High-resolution two-dimensional-encoded in vivo MR images of hand and wrist were obtained at 0.2 T. TRASE exploits RF field phase gradients, and offers the possibility of very low-cost diagnostics and novel experiments exploiting unique capabilities, such as imaging without disturbance of the main B0 magnetic field. Lower field imaging (<1 T) and micro-imaging are favorable application domains as, in both cases, it is technically easier to achieve the short RF pulses desirable for long echo trains, and also to limit RF power deposition. As TRASE is simply an alternative mechanism (and technology) of moving through k space, there are many close analogies between it and conventional B0 -encoded techniques. TRASE is compatible with both B0 gradient encoding and parallel imaging, and so hybrid sequences containing all three spatial encoding approaches are possible.
Collapse
|
25
|
Comparison of T2 and T2*-weighted MR molecular imaging of a mouse model of glioma. BMC Med Imaging 2013; 13:20. [PMID: 23865826 PMCID: PMC3726375 DOI: 10.1186/1471-2342-13-20] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2013] [Accepted: 07/17/2013] [Indexed: 12/13/2022] Open
Abstract
Background Standard MRI has been used for high-grade gliomas detection, albeit with limited success as it does not provide sufficient specificity and sensitivity to detect complex tumor structure. Therefore targeted contrast agents based on iron oxide, that shorten mostly T2 relaxation time, have been recently applied. However pulse sequences for molecular imaging in animal models of gliomas have not been yet fully studied. The aim of this study was therefore to compare contrast-to-noise ratio (CNR) and explain its origin using spin-echo (SE), gradient echo (GE), GE with flow compensation (GEFC) as well as susceptibility weighted imaging (SWI) in T2 and T2* contrast-enhanced molecular MRI of glioma. Methods A mouse model was used. U87MGdEGFRvIII cells (U87MG), derived from a human tumor, were injected intracerebrally. A 9.4 T MRI system was used and MR imaging was performed on the 10 day after the inoculation of the tumor. The CNR was measured prior, 20 min, 2 hrs and 24 hrs post intravenous tail administration of glioma targeted paramagnetic nanoparticles (NPs) using SE, SWI, GE and GEFC pulse sequences. Results The results showed significant differences in CNR among all pulse sequences prior injection. GEFC provided higher CNR post contrast agent injection when compared to GE and SE. Post injection CNR was the highest with SWI and significantly different from any other pulse sequence. Conclusions Molecular MR imaging using targeted contrast agents can enhance the detection of glioma cells at 9.4 T if the optimal pulse sequence is used. Hence, the use of flow compensated pulse sequences, beside SWI, should to be considered in the molecular imaging studies.
Collapse
|
26
|
Detection of (19)F-labeled biopharmaceuticals in cell cultures with magnetic resonance. Adv Drug Deliv Rev 2013; 65:1056-64. [PMID: 23603212 DOI: 10.1016/j.addr.2013.04.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2012] [Revised: 03/18/2013] [Accepted: 04/09/2013] [Indexed: 02/06/2023]
Abstract
Magnetic resonance (MR) studies of the therapeutic efficacy of fluorinated drugs have recently become possible due to improvements in detection including the application of very strong magnetic fields up to 9.4Tesla (T). These advances allow tracking, identification, and quantification of (19)F-labeled biopharmaceuticals using (19)F MR imaging ((19)F MRI) and spectroscopy ((19)F MRS). Both techniques are noninvasive, are nondestructive, and enable serial measurements. They also allow for controlled and systematic studies of cellular metabolism in cancerous tissue in vivo (small animals and humans) and in vitro (body fluids, cells culture, tissue extracts and isolated tissues). Here we provide an overview of the (19)F MRI and (19)F MRS techniques used for tracking (19)F labeled anticancer chemotherapeutics and antibodies which allow quantification of drug uptake in cancer cells in vitro.
Collapse
|
27
|
B1 transmit phase gradient coil for single-axis TRASE RF encoding. Magn Reson Imaging 2013; 31:891-9. [DOI: 10.1016/j.mri.2013.03.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2012] [Revised: 03/06/2013] [Accepted: 03/09/2013] [Indexed: 11/30/2022]
|
28
|
Abstract
BACKGROUND Precise lesion localization is necessary for neurosurgical procedures not only during the operative approach, but also during the preoperative planning phase. OBJECTIVE To evaluate the advantages of 3-dimensional (3-D) brain surface visualization over conventional 2-dimensional (2-D) magnetic resonance images for surgical planning and intraoperative guidance in brain tumor surgery. METHODS Preoperative 3-D brain surface visualization was performed with neurosurgical planning software in 77 cases (58 gliomas, 7 cavernomas, 6 meningiomas, and 6 metastasis). Direct intraoperative navigation on the 3-D brain surface was additionally performed in the last 20 cases with a neurosurgical navigation system. For brain surface reconstruction, patient-specific anatomy was obtained from MR imaging and brain volume was extracted with skull stripping or watershed algorithms, respectively. Three-dimensional visualization was performed by direct volume rendering in both systems. To assess the value of 3-D brain surface visualization for topographic lesion localization, a multiple-choice test was developed. To assess accuracy and reliability of 3-D brain surface visualization for intraoperative orientation, we topographically correlated superficial vessels and gyral anatomy on 3-D brain models with intraoperative images. RESULTS The rate of correct lesion localization with 3-D was significantly higher (P = .001, χ), while being significantly less time consuming (P < .001, χ) compared with 2-D images. Intraoperatively, visual correlation was found between the 3-D images, superficial vessels, and gyral anatomy. CONCLUSION The proposed method of 3-D brain surface visualization is fast, clinically reliable for preoperative anatomic lesion localization and patient-specific planning, and, together with navigation, improves intraoperative orientation in brain tumor surgery and is relatively independent of brain shift.
Collapse
|
29
|
Default mode network functional connectivity altered in failed back surgery syndrome. THE JOURNAL OF PAIN 2013; 14:483-91. [PMID: 23498869 DOI: 10.1016/j.jpain.2012.12.018] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2012] [Revised: 12/13/2012] [Accepted: 12/27/2012] [Indexed: 10/27/2022]
Abstract
UNLABELLED The purpose of this study was to identify alterations in the default mode network of failed back surgery syndrome patients as compared to healthy subjects. Resting state functional magnetic resonance imaging was conducted at 3 Tesla and data were analyzed with an independent component analysis. Results indicate an overall reduced functional connectivity of the default mode network and recruitment of additional pain modulation brain regions, including dorsolateral prefrontal cortex, insula, and additional sensory motor integration brain regions, including precentral and postcentral gyri, for failed back surgery syndrome patients. PERSPECTIVE This article presents alterations in the default mode network of chronic low back pain patients with failed back surgery syndrome as compared to healthy participants.
Collapse
|
30
|
Optimal dye-quencher pairs for the design of an “activatable” nanoprobe for optical imaging. Photochem Photobiol Sci 2013; 12:1824-9. [DOI: 10.1039/c3pp50118c] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
31
|
In vivo open-bore MRI reveals region- and sub-arc-specific lengthening of the unloaded human posterior cruciate ligament. PLoS One 2012; 7:e48714. [PMID: 23144939 PMCID: PMC3492418 DOI: 10.1371/journal.pone.0048714] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2012] [Accepted: 09/28/2012] [Indexed: 11/25/2022] Open
Abstract
Open-bore MRI scanners allow joint soft tissue to be imaged over a large, uninterrupted range of flexion. Using an open-bore scanner, 3D para-sagittal images of the posterior cruciate ligament (PCL) were collected from seven healthy subjects in unloaded, recumbent knee extension and flexion. PCL length was measured from one 2D MRI slice partition per flexion angle, per subject. The anterior surface of the PCL lengthened significantly between extension and flexion (p<0.001). Conversely, the posterior surface did not. Changes were not due to the PCL moving relative to the 2D slice partition; measurements made from 3D reconstructions, which compensated for PCL movement, did not differ significantly from measurements made from 2D slice partitions. In a second experiment, videos of knee flexion were made by imaging two subjects at several flexion angles. Videos allowed soft tissue tracking; examples are included. In a third experiment, unloaded knees of seven healthy, recumbent subjects were imaged at extension and at 40°, 70°, 90°, 100°, 110° and 120° flexion. The distance between PCL attachments increased between extension and 100°, and then decreased (p<0.001). The anterior surface of the PCL lengthened over the flexion angles measured (p<0.01). The posterior surface of the PCL lengthened between extension and 40° and then shortened (p<0.001). Both attachment separation and anterior surface length increased dramatically between extension and 40°, but varied less afterwards. Results indicate that PCL dynamics differ between terminal extension and active function sub-arcs. Also, attachment separation cannot predict the lengthening of all parts of the PCL, nor can lengthening of one part of the PCL predict the lengthening of another part. A potential connection between lengthening and loading is discussed. We conclude that low-field MRI can assess ligament lengthening during flexion, and that the dynamics of the PCL for any given region and sub-arc should be measured directly.
Collapse
|
32
|
Functional MRI of the thoracic spinal cord during vibration sensation. J Magn Reson Imaging 2012; 37:981-5. [PMID: 23011888 DOI: 10.1002/jmri.23819] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Accepted: 08/14/2012] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To demonstrate that it is possible to acquire accurate functional magnetic resonance images from thoracic spinal cord neurons. MATERIALS AND METHODS The lower thoracic spinal dermatomes (T7-T11) on the right side of the body were mechanically stimulated by vibration for 15 participants. Neuronal responses to vibration sensation were measured in the thoracic spinal cord using a HASTE sequence on a 3 Tesla MRI system. RESULTS Signal increases were observed in the corresponding lower thoracic spinal cord segments ipsilateral to the side of stimulation in the dorsal aspect of the spinal cord. CONCLUSION This is the first study to provide proof of principle that functional imaging of the entire thoracic spinal cord is possible, by detecting neuronal activity in the thoracic spinal cord during sensory stimulation using spinal fMRI.
Collapse
|
33
|
NaDyF4 Nanoparticles as T2 Contrast Agents for Ultrahigh Field Magnetic Resonance Imaging. J Phys Chem Lett 2012; 3:524-529. [PMID: 26286058 DOI: 10.1021/jz201664h] [Citation(s) in RCA: 90] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A major limitation of the commonly used clinical MRI contrast agents (CAs) suitable at lower magnetic field strengths (<3.0 T) is their inefficiency at higher fields (>7 T), where next-generation MRI scanners are going. We present dysprosium nanoparticles (β-NaDyF4 NPs) as T2 CAs suitable at ultrahigh fields (9.4 T). These NPs effectively enhance T2 contrast at 9.4 T, which is 10-fold higher than the clinically used T2 CA (Resovist). Evaluation of the relaxivities at 3 and 9.4 T show that the T2 contrast enhances with an increase in NP size and field strength. Specifically, the transverse relaxivity (r2) values at 9.4 T were ∼64 times higher per NP (20.3 nm) and ∼6 times higher per Dy(3+) ion compared to that at 3 T, which is attributed to the Curie spin relaxation mechanism. These results and confirming phantom MR images demonstrate their effectiveness as T2 CAs in ultrahigh field MRIs.
Collapse
|
34
|
Evaluation of brain tumor vessels specific contrast agents for glioblastoma imaging. Neuro Oncol 2012; 14:53-63. [PMID: 22013169 PMCID: PMC3245996 DOI: 10.1093/neuonc/nor183] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2011] [Accepted: 09/02/2011] [Indexed: 11/12/2022] Open
Abstract
A mouse model of glioblastoma multiforme was used to determine the accumulation of a targeted contrast agent in tumor vessels. The contrast agent, consisting of superparamagnetic iron oxide coated with dextran, was functionalized with an anti-insulin-like-growth-factor binding protein 7 (anti-IGFBP7) single domain antibody. The near infrared marker, Cy5.5, was also attached for an in vivo fluorescence study. A 9.4T magnetic resonance imaging (MRI) system was used for in vivo studies on days 10 and 11 following tumor inoculation. T(2) relaxation time was used to measure the accumulation of the contrast agent in the tumor. Changes in tumor to brain contrast because of active targeting were compared with a nontargeted contrast agent. Effective targeting was confirmed with near infrared measurements and fluorescent microscopic analysis. The results showed that there was a statistically significant (P < .01) difference in normalized T(2) between healthy brain and tumor tissue 10 min, 1 h, and 2 h point postinjection of the anti-IGFBP7 single domain antibody targeted and nontargeted iron oxide nanoparticles. A statistical difference remained in animals treated with targeted nanoparticles 24 h postinjection only. The MRI, near infrared imaging, and fluorescent microscopy studies showed corresponding spatial and temporal changes. We concluded that the developed anti-IGFBP7-iron oxide single domain antibody-targeted MRI contrast agent selectively binds to abnormal vessels within a glioblastoma. T(2)-weighted MRI and near infrared imaging are able to detect the targeting effects in brain tumors.
Collapse
|
35
|
|
36
|
Improvements in MR imaging of solids through gradient waveform optimization. CAN J CHEM 2011. [DOI: 10.1139/v11-022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Magnetic resonance imaging (MRI) is known to provide a useful approach for the exploration of the chemistry and dynamics of a wide range of soft condensed materials. However, its application to solids has been limited to those materials with relatively narrow resonances. The time needed to obtain an image of a solid with a given resolution and signal-to-noise ratio (SNR) is directly proportional to the line width of the resonance. For MRI to become practical for the imaging of solids it will have to rely on the development and use of MR sequences that avoid the issues raised by line broadening of the resonance. In this paper we review the latest contributions towards MR imaging of solids from our laboratory, in particular, applications using optimized gradient waveforms. Acoustic noise reduction and SNR improvement obtained with modifications of the standard single-point imaging sequence are presented and discussed using examples.
Collapse
|
37
|
Alterations in glycopeptides associated with herceptin treatment of human breast carcinoma mcf-7 and T-lymphoblastoid cells. Mol Cell Proteomics 2011; 10:M111.007765. [PMID: 21610100 DOI: 10.1074/mcp.m111.007765] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
The therapeutic humanized monoclonal antibody IgG1 known as Herceptin® has shown remarkable antitumor effects. Although this type of therapy has increased the cancer-free survival of patients, not all tumors respond to this treatment and cancers often develop resistance to the antibody. Despite the fact that Herceptin function has been extensively studied, the precise mechanism underlying its antitumor activity still remains incompletely defined. We previously demonstrated on human breast MCF-7 carcinoma and T-lymphoblastoid CEM cells that monoclonal antibody in combination with Lipoplex consisting of Lipofectamine mixed with plasmid DNA showed a more profound effect on cancer cell viability than antibody alone. The analyses of N-glycans isolated from cancer cells showed dramatic differences in profiles when cells were exposed to Herceptin. Moreover, the investigation of glycosylated peptides from the same cancer cell models after treatment revealed further alterations in the post-translational modifications. Tandem mass spectra obtained from the samples treated confirmed the presence of a series of glycopeptides bearing characteristic oligosaccharides as described in IgG1. However some of them differed by mass differences that corresponded to peptide backbones not described previously and more of them were detected from Herceptin treated samples than from cells transfected with Heceptin/Lipoplex. The results indicate that the presence of Lipoplex prevents antibody transformation and elongates its proper function. The better understanding of the multipart changes described in the glycoconjugates could provide new insights into the mechanism by which antibody induces regression in cancers.
Collapse
|
38
|
Quantitative assessment of cardiac output and left ventricular function by noninvasive phase-contrast and cine MRI: validation study with invasive pressure-volume loop analysis in a swine model. J Magn Reson Imaging 2011; 34:203-10. [PMID: 21598342 DOI: 10.1002/jmri.22587] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2010] [Accepted: 03/04/2011] [Indexed: 01/20/2023] Open
Abstract
PURPOSE To validate noninvasive cardiac output measurements of phase-contrast magnetic resonance imaging (PC-MRI) and cine MRI using an invasive pressure-volume (PV) loop technique on a swine model. MATERIALS AND METHODS We compared three methods for evaluating cardiac function at rest and under pharmaceutical low-dose inotropic infusion conditions: 1) phase-contrast MRI, 2) cine MRI, and 3) PV loop relationship. These measurements were made in 14 domestic pigs under rest conditions. Identical MRI acquisitions and PV loop analysis were performed on six pigs from the same group that received an infusion of dobutamine 2.5 μg/kg/min. Cardiac outputs from all measurements were analyzed and compared using linear regression and Bland-Altman analysis. RESULTS Noninvasive PC-MRI and cine MRI did not show any significant differences compared to an invasive PV loop technique for measurement of cardiac output under both rest (PC-MRI, cine MRI, and PV loop, 3.17 ± 0.45, 3.18 ± 0.61, 3.45 ± 0.41 L/min, respectively) and pharmaceutical low-dose inotropic infusion conditions (PC-MRI, cine MRI, and PV loop, 4.78 ± 0.53, 4.7 ± 0.6, 4.96 ± 0.48 L/min, respectively). Statistical analysis showed good agreement of cardiac output measurements at rest (R(2) = 0.83) and under low-dose inotropic infusion conditions (R(2) = 0.74) using PC-MRI and PV loop techniques. Cardiac output measurement using cine MRI and PV loop techniques also showed good agreement at rest (R(2) = 0.85) and under low-dose inotropic infusion conditions (R(2) = 0.76). Furthermore, cardiac outputs determined with the three modalities showed good agreement over a wide range of heart rates (90-180 bpm). CONCLUSION MRI can provide a reliable, noninvasive measurement of cardiac output that can be carried out without the complications that are inherent with current invasive procedures.
Collapse
|
39
|
Corrigendum to ‘Alternate antegrade/retrograde perfusion: an effective technique to preserve hypertrophied hearts during valvular surgery’ [Eur. J. Cardiothorac. Surg. 35 (2009) 69–76]. Eur J Cardiothorac Surg 2011. [DOI: 10.1016/j.ejcts.2011.01.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
40
|
Kinetic analysis of novel mono- and multivalent VHH-fragments and their application for molecular imaging of brain tumours. Br J Pharmacol 2010; 160:1016-28. [PMID: 20590596 DOI: 10.1111/j.1476-5381.2010.00742.x] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND AND PURPOSE The overexpression of epidermal growth factor receptor (EGFR) and its mutated variant EGFRvIII occurs in 50% of glioblastoma multiforme. We developed antibody fragments against EGFR/EGFRvIII for molecular imaging and/or therapeutic targeting applications. EXPERIMENTAL APPROACH An anti-EGFR/EGFRvIII llama single-domain antibody (EG(2)) and two higher valency format constructs, bivalent EG(2)-hFc and pentavalent V2C-EG(2) sdAbs, were analysed in vitro for their binding affinities using surface plasmon resonance and cell binding studies, and in vivo using pharmacokinetic, biodistribution, optical imaging and fluorescent microscopy studies. KEY RESULTS Kinetic binding analyses by surface plasmon resonance revealed intrinsic affinities of 55 nM and 97 nM for the monovalent EG(2) to immobilized extracellular domains of EGFR and EGFRvIII, respectively, and a 10- to 600-fold increases in apparent affinities for the multivalent binders, V2C-EG(2) and EG(2)-hFc, respectively. In vivo pharmacokinetic and biodistribution studies in mice revealed plasma half-lives for EG(2), V2C-EG(2) and EG(2)-hFc of 41 min, 80 min and 12.5 h, respectively, as well as a significantly higher retention of EG(2)-hFc compared to the other two constructs in EGFR/EGFRvIII-expressing orthotopic brain tumours, resulting in the highest signal in the tumour region in optical imaging studies. Time domain volumetric optical imaging fusion with high-resolution micro-computed tomography of microvascular brain network confirmed EG(2)-hFc selective accumulation/retention in anatomically defined tumour regions. CONCLUSIONS Single domain antibodies can be optimized for molecular imaging applications by methods that improve their apparent affinity and prolong plasma half-life and, at the same time, preserve their ability to penetrate tumour parenchyma.
Collapse
|
41
|
|
42
|
N-glycomic changes in human breast carcinoma MCF-7 and T-lymphoblastoid cells after treatment with herceptin and herceptin/Lipoplex. J Proteome Res 2010; 9:1533-40. [PMID: 20063903 DOI: 10.1021/pr9010266] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The humanized monoclonal antibody IgG1 in combination with chemotherapy has been demonstrated to enhance survival benefit in cancer treatment. Despite positive outcomes, some cancer cells develop multidrug resistance. Numerous mechanisms in cancers can be involved in the process of treatment therapy and most of them are not still well understood. To address how the carbohydrate moieties of cells are affected during treatment, the glycan profiles from the two most common cancer cell lines - human breast MCF-7 carcinoma and T-lymphoblastoid CEM cells - were studied here and compared with profiles after treatment with Herceptin alone or in combination with Lipofectamine mixed with plasmid DNA to form Lipoplex. N-Glycans were released from total cells by digestion with PNGaseF and analyzed by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). In summary, both original cell lines showed a dominant occurrence of high-mannose glycans. After treatment, these structures were suppressed and biantennary core-fucosylated glycans originating from IgG1 were the major carbohydrate products identified in cells. The high incidence of additional fucosylated or nonfucosylated galactosylated oligosaccharides, which were not detected in original cells or Herceptin, varied with conditions and time of exposure of cells to the antibody. The results presented in this study provide strong evidence for a role of glycosylation during antibody treatment.
Collapse
|
43
|
19F MRI of 3D CEM cells to study the effects of tocopherols and tocotrienols. J Pharm Biomed Anal 2010; 53:599-602. [PMID: 20439143 DOI: 10.1016/j.jpba.2010.04.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2009] [Revised: 04/06/2010] [Accepted: 04/08/2010] [Indexed: 11/15/2022]
Abstract
Oximetry of the human T-Lymphoblastoid (CEM) cells was measured using (19)F magnetic resonance imaging ((19)F MRI). The cells were treated with the analogues of vitamin E, alpha-, gamma-, delta-tocopherols and corresponding tocotrienols, ex vivo in three-dimensional (3D) cell culture. The study showed that (19)F MRI allows to measure the effect of the analogues due to changes of oxygenation, which were detected using MRI. Hexafluorobenzene was used as a (19)F MRI probe sensitive to oxygen concentrations. After 72h of treatment in HFBR with alpha-, gamma-, delta-tocopherols the oxygen concentration was 19.9+/-0.8%, 19.3+/-1.4%, 16+/-3.5%, respectively. The oxygen concentration in cells treated with alpha-, gamma-, delta-tocotrienols was found to be 14+/-1.5%, 10+/-1.2% and 8.8+/-1.1%, respectively whereas for the control cells it was 22.1+/-1%. The results show that delta-tocopherol and delta-tocotrienol are the most effective treatments in CEM cells among all the tested analogues.
Collapse
|
44
|
Human cervical spinal cord funiculi: Investigation with magnetic resonance diffusion tensor imaging. J Magn Reson Imaging 2010; 31:829-37. [DOI: 10.1002/jmri.22101] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
45
|
Ex vivo assays of CEM cells cultured and treated in the three dimensional cultures. Biomed Pharmacother 2010; 64:390-5. [PMID: 20347572 DOI: 10.1016/j.biopha.2010.02.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2009] [Accepted: 02/21/2010] [Indexed: 01/06/2023] Open
Abstract
This study was aimed at the applications of an ex vivo assays to characterization of CEM (Human T-Lymphoblastoid) cells. CEM cells were cultured in three dimensional (3-D) geometry in the Hollow Fibre Bioreactor (HFB) device. The cells were treated with Herceptin, anti-HER-2 (clone CB-11) and lipoplex containing lipofectamine (LipA) and plasmid DNA. To identify the response to treatment, the viability was established using Trypan blue assays. Magnetic resonance imaging (MRI) at 9.4Tesla (T) was applied for localization of the cells in the HFB device. The structural changes in the cells associated with treatment were examined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The tryptic peptides and glycopeptides detected in treated cells provided evidence of the efficacy of antibody binding to the receptor. The results of the study confirmed that cells growth significantly decreased after treatment with antibodies and transfection with lipoplex.
Collapse
|
46
|
Magnetic resonance molecular imaging of post-stroke neuroinflammation with a P-selectin targeted iron oxide nanoparticle. CONTRAST MEDIA & MOLECULAR IMAGING 2010; 4:305-11. [PMID: 19941323 DOI: 10.1002/cmmi.292] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
We have developed a magnetic resonance molecular imaging method using a novel iron-oxide contrast agent targeted towards P-selectin - MNP-PBP (magnetic nanoparticle-P-selectin binding peptide) - to image endothelial activation following cerebral ischemia/reperfusion. MNP-PBP consists of approximately 1000 PBP ligands (primary sequence: GSIQPRPQIHNDGDFEEIPEEYLQ GGSSLVSVLDLEPLDAAWL) conjugated to a 50 nm diameter aminated dextran iron oxide particle. In vitro P- and E-selectin binding was assessed by competition ELISA. Transient focal cerebral ischemia was induced in male C57/BL 6 mice followed by contrast injection (MNP-PBP; MNP-NH2; Feridex; MNP-PBP-FITC) at 24 h after reperfusion and T(2) magnetic resonance imaging at 9.4 T was performed. Infarction and microvasculature accumulation of contrast agent was assessed in coronal brain sections. MNP-PBP attenuated antibody binding to P-selectin by 34.8 +/- 1.7%. P-selectin was preferentially increased in the infarct hemisphere and MNP-PBP-FITC accumulation in the infarct hemisphere microvasculature was observed. Compared with the nontargeted iron oxide agents MNP-NH2 and Feridex, MNP-PBP showed a significantly greater T(2) effect within the infarction. MR imaging of P-selectin expression with a targeted iron oxide nanoparticle contrast agent may reveal early endothelial activation in stroke and other neuroinflammatory states.
Collapse
|
47
|
Detection of fluorine labeled Herceptin using cellular 19F MRI ex vivo. J Pharm Biomed Anal 2010; 51:894-900. [DOI: 10.1016/j.jpba.2009.10.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2009] [Revised: 10/06/2009] [Accepted: 10/06/2009] [Indexed: 11/30/2022]
|
48
|
Bloch simulations with intra-voxel spin dephasing. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2010; 203:44-51. [PMID: 20022273 DOI: 10.1016/j.jmr.2009.11.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Revised: 11/25/2009] [Accepted: 11/27/2009] [Indexed: 05/28/2023]
Abstract
A common problem in simulations of MRI-experiments based on the numerical solution of the Bloch equations is the finite number of isochromats used in the calculations. This usually results in false or spurious signals and is a source of various differences between calculated and experimentally obtained data. In this paper, we are proposing a technique representing each sample voxel by a central and three additional isochromats, slightly shifted in orthogonal directions from center, thus providing a linear approximation of intra-voxel dephasing. This approach allows for further improvement and precision of the calculated NMR signal and virtually avoids the problem related to an finite set of isochromats. Here we provide details of the algorithm together with examples of simulations which prove the efficiency of this approach.
Collapse
|
49
|
Derivatives of thiocolchicine and its applications to CEM cells treatment using 19F Magnetic Resonance ex vivo. Bioorg Chem 2010; 38:1-6. [DOI: 10.1016/j.bioorg.2009.10.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2009] [Revised: 10/22/2009] [Accepted: 10/26/2009] [Indexed: 11/26/2022]
|
50
|
Combined treatment of human MCF-7 breast carcinoma with antibody, cationic lipid and hyaluronic acid using ex vivo assays. J Pharm Biomed Anal 2010; 51:192-201. [DOI: 10.1016/j.jpba.2009.07.032] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2009] [Revised: 07/22/2009] [Accepted: 07/23/2009] [Indexed: 02/02/2023]
|