Using Electroporation to Improve and Accelerate Zebrafish Embryo Toxicity Testing. MICROMACHINES 2023; 15:49. [PMID: 38258168 PMCID: PMC10819337 DOI: 10.3390/mi15010049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/17/2023] [Accepted: 12/19/2023] [Indexed: 01/24/2024]
Abstract
Zebrafish have emerged as a useful model for biomedical research and have been used in environmental toxicology studies. However, the presence of the chorion during the embryo stage limits cellular exposure to toxic elements and creates the possibility of a false-negative or reduced sensitivity in fish embryo toxicity testing (FET). This paper presents the use of electroporation as a technique to improve the delivery of toxic elements inside the chorion, increasing the exposure level of the toxins at an early embryo stage (<3 h post-fertilization). A custom-made electroporation device with the required electrical circuitry has been developed to position embryos between electrodes that provide electrical pulses to expedite the entry of molecules inside the chorion. The optimized parameters facilitate material entering into the chorion without affecting the survival rate of the embryos. The effectiveness of the electroporation system is demonstrated using Trypan blue dye and gold nanoparticles (AuNPs, 20-40 nm). Our results demonstrate the feasibility of controlling the concentration of dye and nanoparticles delivered inside the chorion by optimizing the electrical parameters, including pulse width, pulse number, and amplitude. Next, we tested silver nanoparticles (AgNPs, 10 nm), a commonly used toxin that can lower mortality, affect heart rate, and cause phenotypic defects. We found that electroporation of AgNPs reduces the exposure time required for toxicity testing from 4 days to hours. Electroporation for FET can provide rapid entry of potential toxins into zebrafish embryos, reducing the time required for toxicity testing and drug delivery experiments.
Collapse
|
2
|
Transgenic expression in zebrafish embryos with an intact chorion by electroporation and microinjection. BIOTECHNOLOGY REPORTS (AMSTERDAM, NETHERLANDS) 2023; 40:e00814. [PMID: 37840570 PMCID: PMC10569972 DOI: 10.1016/j.btre.2023.e00814] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 09/26/2023] [Accepted: 09/30/2023] [Indexed: 10/17/2023]
Abstract
Electroporation is regularly used to deliver agents into cells, including transgenic materials, but it is not used for mutating zebrafish embryos due to the lack of suitable systems, information on appropriate operating parameters, and the challenges posed by the protective chorion. Here, a novel method for gene delivery in zebrafish embryos was developed by combining microinjection into the space between the chorion and the embryo followed by electroporation. This method eliminates the need for chorion removal and injecting into the space between the chorion and embryo eliminates the need for finding and identifying key cell locations before performing an injection, making the process much simpler and more automatable. We also developed a microfluidic electroporation system and optimized electric pulse parameters for transgenesis of embryos. The study provided a novel method for gene delivery in zebrafish embryos that can be potentially implemented in a high throughput transgenesis or mutagenesis system.
Collapse
|
3
|
Characterizing a Silver Nanoparticle-Based Electrochemical Biosensor for Shiga Toxin Detection. ACS OMEGA 2023; 8:40898-40903. [PMID: 37929116 PMCID: PMC10620918 DOI: 10.1021/acsomega.3c06083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 09/28/2023] [Indexed: 11/07/2023]
Abstract
Shiga toxins (1, 2) regularly cause outbreaks and food recalls and pose a significant health risk to the infected population. Therefore, new reliable tools are needed to rapidly detect Shiga toxin cost-effectively in food, water, and wastewater before human consumption. Enzyme immunoassay and polymerase chain reaction approaches are the gold standard detection methods for the Shiga toxin. However, these methods require expensive instruments along with expensive reagents, which makes them hard to convert into point-of-use and low-cost systems. This study introduces an electrochemical biosensing method that utilizes silver nanoparticles (AgNPs) as electrochemical tags and commercially available low-cost screen-printed carbon electrodes for detection. This study introduces the modification of reference electrodes on commercially available screen-printed carbon electrodes to detect AgNPs dissolved in nitric acid. This biosensor achieved a 2 ng/mL lowest measured concentration for Shiga toxin-1 in less than 3 h. These biosensor results also showed that the AgNP-based sensor has better linearity (for graph between peak current vs concentration) and lower standard deviation compared to gold nanoparticles (AuNP)-based electrochemical biosensors.
Collapse
|
4
|
Utilizing ChatGPT to assist CAD design for microfluidic devices. LAB ON A CHIP 2023; 23:3778-3784. [PMID: 37577834 DOI: 10.1039/d3lc00518f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
ChatGPT is a generative AI model that has garnered tremendous public interest due to its ability to solve diverse problems through high-level reasoning and analysis. Among its features is an ability to create and debug code. While this capability has been explored with conventional programming languages such as Python, it has yet to be applied to computer-aided design (CAD). In this work, we utilized GPT-4 to create functional microfluidic components using OpenSCAD, an open-source CAD software package. Through an iterative dialogue, GPT-4 created functional designs for a helix/spiral, a valve, a t-junction, and a serpentine channel. This concept could facilitate CAD in the future for both technical and non-technical users and can be reasonably extended to other fields.
Collapse
|
5
|
Insight into the formation and biological effects of natural organic matter corona on silver nanoparticles in water environment using biased cyclical electrical field-flow fractionation. WATER RESEARCH 2023; 228:119355. [PMID: 36423551 DOI: 10.1016/j.watres.2022.119355] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/08/2022] [Accepted: 11/12/2022] [Indexed: 06/16/2023]
Abstract
Natural organic matter (NOM) readily interacts with nanoparticles, leading to the formation of NOM corona structures on their surface. NOM corona formation is closely related to the surface coatings and bioavailability of nanoparticles. However, the mechanism underlying NOM corona formation on silver nanoparticles (AgNPs) remains largely unknown due to the lack of effective analytical methods for identifying the changes in the AgNP surface. Herein, the separation ability of biased cyclical electrical field-flow fractionation (BCyElFFF) for same-sized polyvinyl pyrrolidone-coated and poly(ethylene glycol)-coated silver nanoparticles (AgNPs) with different electrophoretic mobilities was evaluated under various electrical conditions. Then, the mechanism behind the NOM corona formation on these AgNP surfaces was elucidated based on the changes in the elution time and off-line characterization of the collected fractions during their elution time in a BCyElFFF run. Finally, the survival rates of E. coli exposed to polyvinyl pyrrolidone-coated and poly(ethylene glycol)-coated AgNPs with or without NOM collected during repeated BCyElFFF runs were observed to increase with increasing NOM concentration, clearly demonstrating the negative effect of NOM corona structures on the bioavailability of AgNPs. These findings highlight the powerful separation and isolation ability of BCyElFFF in studying the transformation and fate of nanoparticles in aqueous environments.
Collapse
|
6
|
Multiple-Streams Focusing-Based Cell Separation in High Viscoelasticity Flow. ACS OMEGA 2022; 7:41759-41767. [PMID: 36406492 PMCID: PMC9670260 DOI: 10.1021/acsomega.2c06021] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Accepted: 10/25/2022] [Indexed: 06/16/2023]
Abstract
Viscoelastic flow has been widely used in microfluidic particle separation processes, in which particles get focused on the channel center in diluted viscoelastic flow. In this paper, the transition from single-stream focusing to multiple-streams focusing (MSF) in high viscoelastic flow is observed, which is applied for cell separation processes. Particle focusing stream bifurcation is caused by the balance between elastic force and viscoelastic secondary flow drag force. The influence of cell physical properties, such as cell dimension, shape, and deformability, on the formation of multiple-streams focusing is studied in detail. Particle separation is realized utilizing different separation criteria. The size-based separation of red (RBC) and white (WBC) blood cells is demonstrated in which cells get focused in different streams based on their dimension difference. Cells with different deformabilities get stretched in the viscoelastic flow, leading to the change of focusing streams, and this property is harnessed to separate red blood cells infected with the malaria parasite, Plasmodium falciparum. The achieved results promote our understanding of particle movement in the high viscoelastic flow and enable new particle manipulation and separation processes for sample treatment in biofluids.
Collapse
|
7
|
Separation of U87 glioblastoma cell-derived small and medium extracellular vesicles using elasto-inertial flow focusing (a spiral channel). Sci Rep 2022; 12:6146. [PMID: 35414673 PMCID: PMC9005724 DOI: 10.1038/s41598-022-10129-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 04/01/2022] [Indexed: 11/09/2022] Open
Abstract
Nanoscale and microscale cell-derived extracellular vesicle types and subtypes are of significant interest to researchers in biology and medicine. Extracellular vesicles (EVs) have diagnostic and therapeutic potential in terms of biomarker and nanomedicine applications. To enable such applications, EVs must be isolated from biological fluids or separated from other EV types. Developing methods to fractionate EVs is of great importance to EV researchers. Our goal was to begin to develop a device that would separate medium EVs (mEVs, traditionally termed microvesicles or shedding vesicles) and small EVs (sEVs, traditionally termed exosomes) by elasto-inertial effect. We sought to develop a miniaturized technology that works similar to and provides the benefits of differential ultracentrifugation but is more suitable for EV-based microfluidic applications. The aim of this study was to determine whether we could use elasto-inertial focusing to re-isolate and recover U87 mEVs and sEVs from a mixture of mEVs and sEVs isolated initially by one round of differential ultracentrifugation. The studied spiral channel device can continuously process 5 ml of sample fluid per hour. Using the channel, sEVs and mEVs were recovered and re-isolated from a mixture of U87 glioma cell-derived mEVs and sEVs pre-isolated by one round of differential ultracentrifugation. Following two passes through the spiral channel, approximately 55% of sEVs were recovered with 6% contamination by mEVs (the recovered sEVs contained 6% of the total mEVs). In contrast, recovery of U87 mEVs and sEVs re-isolated using a typical second centrifugation wash step was only 8% and 53%, respectively. The spiral channel also performed similar to differential ultracentrifugation in reisolating sEVs while significantly improving mEV reisolation from a mixture of U87 sEVs and mEVs. Ultimately this technology can also be coupled to other microfluidic EV isolation methods in series and/or parallel to improve isolation and minimize loss of EV subtypes.
Collapse
|
8
|
High efficiency rare sperm separation from biopsy samples in an inertial focusing device. Analyst 2021; 146:3368-3377. [PMID: 33871507 DOI: 10.1039/d1an00480h] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Immotile and rare sperm isolation from a complex cell background is an essential process for infertility treatment. The traditional sperm collection process from a biopsy sample requires long, tedious searches, yet still results in low sperm retrieval. In this work, a high recovery, high throughput sperm separation process is proposed for the clinical biopsy sperm retrieval process. It is found that sperm have different focusing positions compared with non-sperm cells in the inertial flow, which is explained by a sperm alignment phenomenon. Separation in the spiral channel device results in a 95.6% sperm recovery in which 87.4% of non-sperm cells get removed. Rare sperm isolation from a clinical biopsy sample is performed with the current approach. The chance of finding sperm is shown to increase 8.2 fold in the treated samples. The achieved results highly support this method being used for the development of a rapid biopsy sperm sorting process. In addition, the mechanism was proposed and can be applied for the high-efficiency separation of non-spherical particles in general.
Collapse
|
9
|
Development and Testing of a Continuous Flow-Electrical-Split-Flow Lateral Transport Thin Separation System (Fl-El-SPLITT). Anal Chem 2021; 93:2888-2897. [PMID: 33476126 DOI: 10.1021/acs.analchem.0c04345] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
In this work, a new high-volume, continuous particle separation device that separates based upon size and charge is described. Two continuous flow-electrical-split-flow lateral transport thin (Fl-El-SPLITT) device architectures (a platinum electrode on a porous membrane and a porous graphite electrode under a membrane) were developed and shown to improve particle separations over a purely electrical-SPLITT device. The graphite FL-El-SPLITT device architecture achieved the best separation of approximately 60% of small (28 nm) vs large (1000 nm) polystyrene particles. Fl-El-SPLITT (platinum) achieved a 75% separation on a single pass using these same particles. Fl-El-SPLITT (platinum) achieved a moderate 26% continuous separation of U87 glioma cell-derived small extracellular vesicles (EVs) from medium EVs. Control parameter testing showed that El-SPLITT continuously directed particle motility within a channel to exit a selected port based upon the applied voltage using either direct current or alternating current. The transition from one port to the other was dependent upon the voltage applied. Both large and small polystyrene particles transitioned together rather than separating at each of the applied voltages. These data present the first ever validation of El-SPLITT in continuous versus batch format. The Fl-El-SPLITT device architecture, monitoring, and electrical and fluid interfacing systems are described in detail for the first time. Capabilities afforded to the system by the flow addition include enhanced particle separation as well as the ability to filter out small particles or desalinate fluids. High-throughput continuous separations based upon electrophoretic mobility will be streamlined by this new technique that combines electrical and flow fields into a single device.
Collapse
|
10
|
SARS-CoV-2 pandemic: a review of molecular diagnostic tools including sample collection and commercial response with associated advantages and limitations. Anal Bioanal Chem 2021; 413:49-71. [PMID: 33073312 PMCID: PMC7568947 DOI: 10.1007/s00216-020-02958-1] [Citation(s) in RCA: 80] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 09/03/2020] [Accepted: 09/16/2020] [Indexed: 12/18/2022]
Abstract
The unprecedented global pandemic known as SARS-CoV-2 has exercised to its limits nearly all aspects of modern viral diagnostics. In doing so, it has illuminated both the advantages and limitations of current technologies. Tremendous effort has been put forth to expand our capacity to diagnose this deadly virus. In this work, we put forth key observations in the functionality of current methods for SARS-CoV-2 diagnostic testing. These methods include nucleic acid amplification-, CRISPR-, sequencing-, antigen-, and antibody-based detection methods. Additionally, we include analysis of equally critical aspects of COVID-19 diagnostics, including sample collection and preparation, testing models, and commercial response. We emphasize the integrated nature of assays, wherein issues in sample collection and preparation could impact the overall performance in a clinical setting.
Collapse
|
11
|
Optimization of a microfluidic spiral channel used to separate sperm from blood cells. BIOMICROFLUIDICS 2020; 14:064103. [PMID: 33193937 PMCID: PMC7647613 DOI: 10.1063/5.0029508] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Accepted: 10/25/2020] [Indexed: 06/11/2023]
Abstract
Assisted reproductive technology includes medical procedures that confront the problem of infertility. In some cases of male infertility, blood cells are present in the sperm containing samples and must be removed. Spiral-channel devices have been developed to perform this task, but there is a strong need to increase their throughput. In this work, the theory behind the separation is employed to optimize the device for increased throughput. An existing device that is known to separate sperm and blood cells with a rectangular cross section of 600 × 100 μm2 was used as the baseline. Using its physics, theoretical models were generated to explore theoretical performances of larger-size channels. The models suggested that a channel of size 800 × 133 μm2 would likely work. This geometry enabled the throughput to be increased by 50%, from 2 ml/min in the case of the baseline-size to 3 ml/min in the designed device. Experiments using the larger device resulted in a recovery of more than 90% of sperm cells while removing 89% of red blood cells (RBCs). In comparison, the reference device results in a 90% recovery of sperm cells while removing 74% of white blood cells (WBCs). The length of the channel was also reduced to reduce the pressure required to operate the chip. Literature has shown the removal of WBCs to be higher than that of RBCs due to their larger size, spherical shape, and comparatively low deformability, suggesting that the revised chip would be faster and better for the separation of sperm and all blood cells.
Collapse
|
12
|
Characterization of Human Glioblastoma versus Normal Plasma-Derived Extracellular Vesicles Preisolated by Differential Centrifugation Using Cyclical Electrical Field-Flow Fractionation. Anal Chem 2020; 92:9866-9876. [DOI: 10.1021/acs.analchem.0c01373] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
13
|
Microfluidic System for Rapid Isolation of Sperm From Microdissection TESE Specimens. Urology 2020; 140:70-76. [DOI: 10.1016/j.urology.2019.12.053] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 11/12/2019] [Accepted: 12/18/2019] [Indexed: 01/28/2023]
|
14
|
Towards a better testicular sperm extraction: novel sperm sorting technologies for non-motile sperm extracted by microdissection TESE. Transl Androl Urol 2020; 9:S206-S214. [PMID: 32257861 PMCID: PMC7108989 DOI: 10.21037/tau.2019.08.36] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Non-obstructive azoospermia (NOA) is the most severe form of male factor infertility. It is characterized by a lack of spermatogenesis in the seminiferous tubules. Microdissection testicular sperm extraction (microTESE) has significantly improved testicular sperm retrieval rates compared to conventional techniques for NOA. Following testicular biopsy, the sperm is usually non-motile and contained within seminiferous tubules requiring extensive laboratory processing to find individual sperm sufficient for artificial reproductive technologies (ART). Current techniques include mechanical and enzymatic processing which is time-consuming and often damaging to sperm. We review novel techniques that may help improve sperm retrieval rates after microTESE including microfluidics (dielectrophoretic cell sorting, spiral channel sorting, and pinched flow fractionation), fluorescence-activated cell sorting (FACS), and magnetic-activated cell sorting (MACS).
Collapse
|
15
|
A Tunable Microfluidic Device Enables Cargo Encapsulation by Cell- or Organelle-Sized Lipid Vesicles Comprising Asymmetric Lipid Bilayers. ACTA ACUST UNITED AC 2019; 3. [PMID: 31428671 DOI: 10.1002/adbi.201900010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Cellular membranes play host to a wide variety of morphologically and chemically complex processes. Although model membranes, like liposomes, are already widely used to reconstitute and study these processes, better tools are needed for making model bilayers that faithfully mimic cellular membranes. Existing methods for fabricating cell-sized (μm) or organelle-sized (tens to hundreds of nanometers) lipid vesicles have distinctly different requirements. Of particular note for biology, it remains challenging for any technique to efficiently encapsulate fragile cargo molecules or to generate liposomes with stable, asymmetric lipid leaflets within the bilayer. Here a tunable microfluidic device and protocol for fabricating liposomes with desired diameters ranging from ≈10 μm to ≈100 nm are described. Lipid vesicle size is templated by the simple inclusion of a polycarbonate filter within the microfluidic system and tuned with flow rate. It is shown that the vesicles made with this device are stable, unilamellar, lipid asymmetric, and capable of supporting transmembrane protein assembly, peripheral membrane protein binding, as well as soluble cargo encapsulation (including designer nanocages for biotechnology applications). These fabricated vesicles provide a new platform for studying the biophysically rich processes found within lipid-lipid and lipid-protein systems typically associated with cellular membranes.
Collapse
|
16
|
Hydrodynamic cavitation for the rapid separation and electrochemical detection of Cryptosporidium parvum and Escherichia coli O157:H7 in ground beef. Biosens Bioelectron 2019; 135:137-144. [PMID: 31005765 DOI: 10.1016/j.bios.2019.04.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 03/13/2019] [Accepted: 04/01/2019] [Indexed: 11/30/2022]
Abstract
Foodborne illnesses are a major contributor to misery and health challenges in both rich and poor nations. Illnesses from pathogens such as Escherichia coli and Cryptosporidium parvum oocysts account for most of the cases of diarrhea in the world. Many standard methods exist for detecting these pathogens in water. However, these standard methods do not readily translate to the detection of the same pathogens in food. Detection techniques for pathogens in food are often inadequate, due to their inability to completely separate pathogens from food matrices. In this paper, we present a technique to separate and detect both Escherichia coli cells and Cryptosporidium parvum oocysts that have been embedded in ground meat. We achieve this objective by combining enzymatic digestion of the meat, hydrodynamic cavitation to disassemble pathogens from the meat, immunomagnetic separation to purify meat samples and indirect electrochemical detection of the target pathogens. Our use of hydrodynamic cavitation to separate pathogens is compared against an industry standard separation technique. Results indicate that the use of hydrodynamic cavitation amplifies the detection capabilities of our sensing technique and is overall comparable to or better than conventional stomacher sample preparation.
Collapse
|
17
|
Skeletal muscle interstitial fluid metabolomics at rest and associated with an exercise bout: application in rats and humans. Am J Physiol Endocrinol Metab 2019; 316:E43-E53. [PMID: 30398905 PMCID: PMC6417688 DOI: 10.1152/ajpendo.00156.2018] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Blood or biopsies are often used to characterize metabolites that are modulated by exercising muscle. However, blood has inputs derived from multiple tissues, biopsies cannot discriminate between secreted and intracellular metabolites, and their invasive nature is challenging for frequent collections in sensitive populations (e.g., children and pregnant women). Thus, minimally invasive approaches to interstitial fluid (IF) metabolomics would be valuable. A catheter was designed to collect IF from the gastrocnemius muscle of acutely anesthetized adult male rats at rest or immediately following 20 min of exercise (~60% of maximal O2 uptake). Nontargeted, gas chromatography-time-of-flight mass spectrometry analysis was used to detect 299 metabolites, including nonannotated metabolites, sugars, fatty acids, amino acids, and purine metabolites and derivatives. Just 43% of all detected metabolites were common to IF and blood plasma, and only 20% of exercise-modified metabolites were shared in both pools, highlighting that the blood does not fully reflect the metabolic outcomes in muscle. Notable exercise patterns included increased IF amino acids (except leucine and isoleucine), increased α-ketoglutarate and citrate (which may reflect tricarboxylic acid cataplerosis or shifts in nonmitochondrial pathways), and higher concentration of the signaling lipid oleamide. A preliminary study of human muscle IF was conducted using a 20-kDa microdialysis catheter placed in the vastus lateralis of five healthy adults at rest and during exercise (65% of estimated maximal heart rate). Approximately 70% of commonly detected metabolites discriminating rest vs. exercise in rats were also changed in exercising humans. Interstitium metabolomics may aid in the identification of molecules that signal muscle work (e.g., exertion and fatigue) and muscle health.
Collapse
|
18
|
Exosome Isolation: Cyclical Electrical Field Flow Fractionation in Low-Ionic-Strength Fluids. Anal Chem 2018; 90:12783-12790. [PMID: 30346136 DOI: 10.1021/acs.analchem.8b03146] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
The influence of buffer substitution and dilution effects on exosome size and electrophoretic mobility were shown for the first time. Cyclical electrical field flow fractionation (Cy-El-FFF) in various substituted fluids was applied to exosomes and other particles. Tested carrier fluids of deionized (DI) water, 1× phosphate buffered saline (PBS), 0.308 M trehalose, and 2% isopropyl alcohol (IPA) influenced Cy-El-FFF-mediated isolation of A375 melanoma exosomes. All fractograms revealed a crescent-shaped trend in retention times with increasing voltage with the maximum retention time at ∼1.3 V AC. A375 melanoma exosome recovery was approximately 70-80% after each buffer substitution, and recovery was independent of whether the sample was substituted into 1× PBS or DI water. Exosome dilution in deionized water produced a U-shaped dependence on electrophoretic mobility. The effect of dilution using 1× PBS buffer revealed a very gradual change in electrophoretic mobility of exosomes from ∼-1.6 to -0.1 μm cm/s V, as exosome concentration was decreased. This differed from the use of DI water, where a large change from ∼-5.5 to -0.1 μm cm/s V over the same dilution range was observed. Fractograms of separated A375 melanoma exosomes in two substituted low-ionic-strength buffers were compared with synthetic particle fractograms. Overall, the ability of Cy-El-FFF to separate exosomes based on their size and charge is a highly promising, label-free approach to initially catalogue and purify exosome subtypes for biobanking as well as to enable further exosome subtype interrogations.
Collapse
|
19
|
Abstract
Transparent surfaces within microfluidic devices are essential for accurate quantification of chemical, biological, and mechanical interactions. Here, we report how to create low-cost, rapid 3D-printed microfluidic devices that are optically free from artifacts and have transparent surfaces suitable for visualizing a variety of fluid phenomenon. The methodology described here can be used for creating high-pressure microfluidic systems (significantly higher than PDMS-glass bonding). We develop methods for annealing Poly-Lactic Acid (PLA) microfluidic devices demonstrating heat resistance typically not achievable with other plastic materials. We show DNA melting and subsequent fluorescent imaging analysis, opening the door to other high-temperature applications. The FDM techniques demonstrated here allow for fabrication of microfluidic devices for precise visualization of interfacial dynamics, whether mixing between two laminar streams or droplet tracking. In addition to these characterizations, we include a printer troubleshooting guide and printing recipes for device fabrication to facilitate FDM printing for microfluidic device development.
Collapse
|
20
|
|
21
|
Electrochemical Detection of E. coli O157:H7 in Water after Electrocatalytic and Ultraviolet Treatments Using a Polyguanine-Labeled Secondary Bead Sensor. SENSORS 2018; 18:s18051497. [PMID: 29747467 PMCID: PMC5981196 DOI: 10.3390/s18051497] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 05/01/2018] [Accepted: 05/07/2018] [Indexed: 12/16/2022]
Abstract
The availability of clean drinking water is a significant problem worldwide. Many technologies exist for purifying drinking water, however, many of these methods require chemicals or use simple methods, such as boiling and filtering, which may or may not be effective in removing waterborne pathogens. Present methods for detecting pathogens in point-of-use (POU) sterilized water are typically time prohibitive or have limited ability differentiating between active and inactive cells. This work describes a rapid electrochemical sensor to differentially detect the presence of active Escherichia coli (E. coli) O157:H7 in samples that have been partially or completely sterilized using a new POU electrocatalytic water purification technology based on superradicals generated by defect laden titania (TiO2) nanotubes. The sensor was also used to detect pathogens sterilized by UV-C radiation for a comparison of different modes of cell death. The sensor utilizes immunomagnetic bead separation to isolate active bacteria by forming a sandwich assay comprised of antibody functionalized secondary magnetic beads, E. coli O157:H7, and polyguanine (polyG) oligonucleotide functionalized secondary polystyrene beads as an electrochemical tag. The assay is formed by the attachment of antibodies to active receptors on the membrane of E. coli, allowing the sensor to differentially detect viable cells. Ultravioloet (UV)-C radiation and an electrocatalytic reactor (ER) with integrated defect-laden titania nanotubes were used to examine the sensors’ performance in detecting sterilized cells under different modes of cell death. Plate counts and flow cytometry were used to quantify disinfection efficacy and cell damage. It was found that the ER treatments shredded the bacteria into multiple fragments, while UV-C treatments inactivated the bacteria but left the cell membrane mostly intact.
Collapse
|
22
|
An automated system for rapid cellular extraction from live zebrafish embryos and larvae: Development and application to genotyping. PLoS One 2018; 13:e0193180. [PMID: 29543903 PMCID: PMC5854293 DOI: 10.1371/journal.pone.0193180] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Accepted: 02/06/2018] [Indexed: 01/31/2023] Open
Abstract
Zebrafish are a valuable model organism in biomedical research. Their rapid development, ability to model human diseases, utility for testing genetic variants identified from next-generation sequencing, amenity to CRISPR mutagenesis, and potential for therapeutic compound screening, has led to their wide-spread adoption in diverse fields of study. However, their power for large-scale screens is limited by the absence of automated genotyping tools for live animals. This constrains potential drug screen options, limits analysis of embryonic and larval phenotypes, and requires raising additional animals to adulthood to ensure obtaining an animal of the desired genotype. Our objective was to develop an automated system that would rapidly obtain cells and DNA from zebrafish embryos and larvae for genotyping, and that would keep the animals alive. We describe the development, testing, and validation of a zebrafish embryonic genotyping device, termed “ZEG” (Zebrafish Embryo Genotyper). Using microfluidic harmonic oscillation of the animal on a roughened glass surface, the ZEG is able to obtain genetic material (cells and DNA) for use in genotyping, from 24 embryos or larvae simultaneously in less than 10 minutes. Loading and unloading of the ZEG is performed manually with a standard pipette tip or transfer pipette. The obtained genetic material is amplified by PCR and can be used for subsequent analysis including sequencing, gel electrophoresis, or high-resolution melt-analysis. Sensitivity of genotyping and survival of animals are both greater than 90%. There are no apparent effects on body morphology, development, or motor behavior tests. In summary, the ZEG device enables rapid genotyping of live zebrafish embryos and larvae, and animals are available for downstream applications, testing, or raising.
Collapse
|
23
|
|
24
|
Separation of sperm cells from samples containing high concentrations of white blood cells using a spiral channel. BIOMICROFLUIDICS 2017; 11:054106. [PMID: 29034050 PMCID: PMC5617737 DOI: 10.1063/1.4994548] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Accepted: 08/24/2017] [Indexed: 05/21/2023]
Abstract
Microfluidic technology has potential to separate sperm cells from unwanted debris while improving the effectiveness of assisted reproductive technologies (ART). Current clinical protocol limitations regarding the separation of sperm cells from other cells/cellular debris can lead to low sperm recovery when the sample contains a low concentration of mostly low motility sperm cells and a high concentration of unwanted cells/cellular debris, such as in semen samples from patients with pyospermia [high white blood cell (WBC) semen]. This study demonstrates label-free separation of sperm cells from such semen samples using inertial microfluidics. The approach does not require any externally applied forces except the movement of the fluid sample through the instrument. Using this approach, it was possible to recover not only any motile sperm, but also viable less-motile and non-motile sperm cells with high recovery rates. Our results demonstrate the ability of inertial microfluidics to significantly reduce WBC concentration by flow focusing of target WBCs within a spiral channel flow. The estimated sample process time was more rapid (∼5 min) and autonomous than the conventional method (gradient centrifuge sperm wash; ∼1 h). A mixture of sperm/WBC was injected as the device input and 83% of sperm cells and 93% of WBCs were collected separately from two distinct outlets. The results show promise for enhancing sperm samples through inertial flow processing of WBCs and sperm cells that can provide an advantage to ART procedures such as sample preparation for intrauterine insemination.
Collapse
|
25
|
|
26
|
Abstract
Non-obstructive azoospermia (NOA) is a severe form of infertility accounting for 10% of infertile men. Microdissection testicular sperm extraction (microTESE) includes a set of clinical protocols from which viable sperm are collected from patients (suffering from NOA), for intracytoplasmic sperm injection (ICSI). Clinical protocols associated with the processing of a microTESE sample are inefficient and significantly reduce the success of obtaining a viable sperm population. In this review we highlight the sources of these inefficiencies and how these sources can possibly be removed by microfluidic technology and single-cell Raman spectroscopy.
Collapse
|
27
|
Transdermal Delivery of siRNA through Microneedle Array. Sci Rep 2016; 6:21422. [PMID: 26888011 PMCID: PMC4757825 DOI: 10.1038/srep21422] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 01/22/2016] [Indexed: 01/07/2023] Open
Abstract
Successful development of siRNA therapies has significant potential for the treatment of skin conditions (alopecia, allergic skin diseases, hyperpigmentation, psoriasis, skin cancer, pachyonychia congenital) caused by aberrant gene expression. Although hypodermic needles can be used to effectively deliver siRNA through the stratum corneum, the major challenge is that this approach is painful and the effects are restricted to the injection site. Microneedle arrays may represent a better way to deliver siRNAs across the stratum corneum. In this study, we evaluated for the first time the ability of the solid silicon microneedle array for punching holes to deliver cholesterol-modified housekeeping gene (Gapdh) siRNA to the mouse ear skin. Treating the ear with microneedles showed permeation of siRNA in the skin and could reduce Gapdh gene expression up to 66% in the skin without accumulation in the major organs. The results showed that microneedle arrays could effectively deliver siRNA to relevant regions of the skin noninvasively.
Collapse
|
28
|
Abstract
This paper introduces an innovative method for genotyping 1-2 days old zebrafish embryos, without sacrificing the life/health of the embryos. The method utilizes microfluidic technology to extract and collect a small amount of genetic material from the chorionic fluid or fin tissue of the embryo. Then, using conventional DNA extraction, PCR amplification, and high resolution melt analysis with fluorescent DNA detection techniques, the embryo is genotyped. The chorionic fluid approach was successful 78% of the time while the fin clipping method was successful 100% of the time. Chorionic fluid was shown to only contain DNA from the embryo and not from the mother. These results suggest a novel method to genotype zebrafish embryos that can facilitate high-throughput screening, while maintaining 100% viability of the embryo.
Collapse
|
29
|
|
30
|
Optimization and Evaluation of a Vascular Coupling Device for End-to-End Anastomosis: A Finite-Element Analysis. J Med Device 2015. [DOI: 10.1115/1.4031810] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Currently, end-to-end anastomosis of blood vessels is performed using suturing, which is time consuming, expensive, and subject to large degrees of human error. One promising alternative is a ring–pin coupling device. This device has been shown to be useful for venous anastomosis, but lacks the versatility necessary for arterial applications. The purpose of this study was to optimize a vascular coupling design that could be used for arteries and veins of various sizes. To achieve this, finite-element (FE) analysis was used to simulate the vessel–device interaction during anastomosis. Parametric simulations were performed to optimize the number of pins, the wing pivot point, and the pin offset of the design. The interaction of the coupler with various blood vessel sizes was also evaluated. Maximum strain in the vessel wall increased with the number of pins. The positions of the wings and pins were also important in dictating maximum strain, and improper dimensions lead to failure of the installation process. Extra force applied to the distal end of the vessel, or a supplementary tool, will be required during the coupler installation process to prevent vessels less than 3 mm inner diameter (0.5 mm wall thickness) from slipping off the coupler.
Collapse
|
31
|
A New Vascular Coupler Design for End-to-End Anastomosis: Fabrication and Proof-of-Concept Evaluation. J Med Device 2015. [DOI: 10.1115/1.4029924] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Traditional hand-suturing for vascular connection techniques is time consuming, expensive, and requires highly complex instruments and technical expertise. The aim of this study is to develop a new vascular coupler that can be used in end-to-end anastomosis surgery in an easier and more efficient way for both arteries and veins. The vascular coupler has four rotatable wings and one translatable spike in each wing. Prototypes were manufactured using polytetrafluoroethylene (PTFE) and high-density polyethylene (HDPE). A set of installation tools was designed to facilitate the anastomosis process. Proof-of-concept testing with the vascular coupler using plastic tubes and porcine cadaver vessels showed that the coupler should work as designed. A simplified finite element (FE) model assisted in the evaluation of the tearing likelihood of human vessels during installation of the coupler. Results of tests on the coupler showed that the vascular coupler could be efficiently attached to blood vessels, did not leak after the anastomosis was performed, had sufficient joint strength, and had little impact on flow in the vessel. The entire anastomosis process can be completed in 3 min when using the vascular coupler to join porcine cadaver vessels.
Collapse
|
32
|
Field and flow-based separations. Anal Bioanal Chem 2015; 407:4299-300. [DOI: 10.1007/s00216-015-8690-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
33
|
Highly sensitive bacteria quantification using immunomagnetic separation and electrochemical detection of guanine-labeled secondary beads. SENSORS (BASEL, SWITZERLAND) 2015; 15:12034-52. [PMID: 26007743 PMCID: PMC4481928 DOI: 10.3390/s150512034] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Accepted: 05/07/2015] [Indexed: 12/26/2022]
Abstract
In this paper, we report the ultra-sensitive indirect electrochemical detection of E. coli O157:H7 using antibody functionalized primary (magnetic) beads for capture and polyguanine (polyG) oligonucleotide functionalized secondary (polystyrene) beads as an electrochemical tag. Vacuum filtration in combination with E. coli O157:H7 specific antibody modified magnetic beads were used for extraction of E. coli O157:H7 from 100 mL samples. The magnetic bead conjugated E. coli O157:H7 cells were then attached to polyG functionalized secondary beads to form a sandwich complex (magnetic bead/E. coli secondary bead). While the use of magnetic beads for immuno-based capture is well characterized, the use of oligonucleotide functionalized secondary beads helps combine amplification and potential multiplexing into the system. The antibody functionalized secondary beads can be easily modified with a different antibody to detect other pathogens from the same sample and enable potential multiplexing. The polyGs on the secondary beads enable signal amplification up to 10⁸ guanine tags per secondary bead (7.5 x 10⁶ biotin-FITC per secondary bead, 20 guanines per oligonucleotide) bound to the target (E. coli). A single-stranded DNA probe functionalized reduced graphene oxide modified glassy carbon electrode was used to bind the polyGs on the secondary beads. Fluorescent imaging was performed to confirm the hybridization of the complex to the electrode surface. Differential pulse voltammetry (DPV) was used to quantify the amount of polyG involved in the hybridization event with tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) as the mediator. The amount of polyG signal can be correlated to the amount of E. coli O157:H7 in the sample. The method was able to detect concentrations of E. coli O157:H7 down to 3 CFU/100 mL, which is 67 times lower than the most sensitive technique reported in literature. The signal to noise ratio for this work was 3. We also demonstrate the use of the protocol for detection of E. coli O157:H7 seeded in waste water effluent samples.
Collapse
|
34
|
Abstract
Of the diverse analytical tools used in proteomics, protein microarrays possess the greatest potential for providing fundamental information on protein, ligand, analyte, receptor, and antibody affinity-based interactions, binding partners and high-throughput analysis. Microarrays have been used to develop tools for drug screening, disease diagnosis, biochemical pathway mapping, protein-protein interaction analysis, vaccine development, enzyme-substrate profiling, and immuno-profiling. While the promise of the technology is intriguing, it is yet to be realized. Many challenges remain to be addressed to allow these methods to meet technical and research expectations, provide reliable assay answers, and to reliably diversify their capabilities. Critical issues include: (1) inconsistent printed microspot morphologies and uniformities, (2) low signal-to-noise ratios due to factors such as complex surface capture protocols, contamination, and static or no-flow mass transport conditions, (3) inconsistent quantification of captured signal due to spot uniformity issues, (4) non-optimal protocol conditions such as pH, temperature, drying that promote variability in assay kinetics, and lastly (5) poor protein (e.g., antibody) printing, storage, or shelf-life compatibility with common microarray assay fabrication methods, directly related to microarray protocols. Conventional printing approaches, including contact (e.g., quill and solid pin), non-contact (e.g., piezo and inkjet), microfluidics-based, microstamping, lithography, and cell-free protein expression microarrays, have all been used with varying degrees of success with figures of merit often defined arbitrarily without comparisons to standards, or analytical or fiduciary controls. Many microarray performance reports use bench top analyte preparations lacking real-world relevance, akin to "fishing in a barrel", for proof of concept and determinations of figures of merit. This review critiques current protein-based microarray preparation techniques commonly used for analytical and function-based proteomics and their effects on array-based assay performance.
Collapse
|
35
|
Quasi-digital PCR: Enrichment and quantification of rare DNA variants. Biomed Microdevices 2015; 16:639-44. [PMID: 24781884 DOI: 10.1007/s10544-014-9866-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Rare variant enrichment and quantification was achieved by allele-specific, competitive blocker, digital PCR for aiming to provide a noninvasive method for detecting rare DNA variants from circulating cells. The allele-specific blocking chemistry improves sensitivity and lowers assay cost over previously described digital PCR methods while the instrumentation allowed for rapid thermal cycling for faster turnaround time. Because the digital counting of the amplified variants occurs in the presence of many wild-type templates in each well, the method is called "quasi-digital PCR". A spinning disk was used to separate samples into 1000 wells, followed by rapid-cycle, allele-specific amplification in the presence of a molecular beacon that serves as both a blocker and digital indicator. Monte Carlo simulations gave similar results to Poisson distribution statistics for mean number of template molecules and provided an upper and lower bound at a specified confidence level and accounted for input DNA concentration variation. A 111 bp genomic DNA fragment including the BRAF p.V600E mutation (c.T1799A) was amplified with quasi-digital PCR using cycle times of 23 s. Dilution series confirmed that wild-type amplification was suppressed and that the sensitivity for the mutant allele was <0.01 % (43 mutant alleles amongst 500,000 wild-type alleles). The Monte Carlo method presented here is publically available on the internet and can calculate target concentration given digital data or predict digital data given target concentration.
Collapse
|
36
|
Design, fabrication, and testing of a novel end-to-end vascular coupling system. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:6593-6. [PMID: 25571507 DOI: 10.1109/embc.2014.6945139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Microvascular anastomosis is common and necessary during reconstructive and free tissue transfer surgeries. Traditional hand suturing techniques are time consuming, subject to human error, and require complex instruments. Prior attempts including staples, ring-pin devices, cuffing devices, and clips were either more cumbersome, were unable to maintain a tight seal, or did not work for both arteries and veins. To provide a more efficient and reliable vessel anastomosis, a pin-free vascular coupling system that can be used for both arteries and veins was designed and manufactured. A set of corresponding instruments were developed to facilitate the anastomosis process. Both bench testing and ex vivo testing were performed to evaluate the operating abilities of the vascular coupling system. Preliminary studies were performed on cadaver pigs.
Collapse
|
37
|
Microfluidic devices for rapid and sensitive identification of organisms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:774-7. [PMID: 25570073 DOI: 10.1109/embc.2014.6943705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Microfluidic devices for rapid and highly sensitive detection of living organisms were developed for two applications. First, a zebrafish embryo genotyping system was developed and shown to be able to genotype embryos in the first 48 hours of the embryos life without damaging the embryos in any apparent way. Second, a highly sensitive bacteria detection platform has been developed for the rapid detection of pathogens. The system relies on a magnetic bead extraction followed by secondary bead attachment. The secondary beads are barcoded with DNA sequences highly enriched for Gs. The guanine molecules generate an electrochemical response after they are released from the secondary beads and detected at a sensing location downstream from the beads. The amplification with the efficient washing procedures leads to a limit of detection of 3 CFU in 100 mL of water.
Collapse
|
38
|
Optimal tube length for the submerged printing of ovarian cancer cells. BIOMEDICAL SCIENCES INSTRUMENTATION 2015; 51:17-23. [PMID: 25996694] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Ovarian cancer is the fifth most common cancer affecting US women, killing more women each year than all other gynecologic cancers combined. Treatment of ovarian cancer is challenging with an overall 5-year survival rates of only 28-46% based on the metastatic state of the disease. While overall survival has improved with modern chemotherapy, poor outcomes have persisted. One of the greatest challenges in cancer therapeutic research remains that late-stage drug development trials for drug candidates have high attrition rates, up to 70% in Phase II and 59% in Phase III trials. The development of in vitro, high-throughput, cell based assays could provide a tool to overcome the challenges associated with high attrition rates by allowing for controlled cell deposition with a defined, controlled phenotype. Submerged, three-dimensional (3D) microfluidic printing technology is uniquely capable of controlling cell deposition without sacrificing the viability of cells for cell-based assays. Here, we investigate the phenotypic effects of tube length during printing on the cells. We observe that the length of the tube has minimal effects on the viability and density of A2780 ovarian cancer cells different cell lines. This study details foundational information for developing a high-throughput cell-based assays (CBA) for screening effective cancer drug candidates.
Collapse
|
39
|
Contact lens biofuel cell tested in a synthetic tear solution. Biosens Bioelectron 2014; 68:142-148. [PMID: 25562741 DOI: 10.1016/j.bios.2014.12.034] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Revised: 12/14/2014] [Accepted: 12/15/2014] [Indexed: 11/29/2022]
Abstract
A contact lens biofuel cell was fabricated using buckypaper electrodes cured on a silicone elastomer soft contact lens. The buckypaper anode consisted of poly(methylene green) and a hydrogel matrix containing lactate dehydrogenase and nicotinamide adenine dinucleotide hydrate (NAD(+)). The buckypaper cathode was modified with 1-pyrenemethyl anthracene-2-carboxylate, and then bilirubin oxidase was immobilized within a polymer. Contact lens biofuel cell testing was performed in a synthetic tear solution at 35°C. The open circuit voltage was 0.413±0.06 V and the maximum current and power density were 61.3±2.9 µA cm(-2) and 8.01±1.4 µWc m(-2), respectively. Continuous operation for 17h revealed anode instability as output current rapidly decreased in the first 4h and then stabilized for the next 13 h. The contact lens biofuel cell presented here is a step toward achieving self-powered electronic contact lenses and ocular devices with an integrated power source.
Collapse
|
40
|
The submerged printing of cells onto a modified surface using a continuous flow microspotter. J Vis Exp 2014. [PMID: 24796939 DOI: 10.3791/51273] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
The printing of cells for microarray applications possesses significant challenges including the problem of maintaining physiologically relevant cell phenotype after printing, poor organization and distribution of desired cells, and the inability to deliver drugs and/or nutrients to targeted areas in the array. Our 3D microfluidic printing technology is uniquely capable of sealing and printing arrays of cells onto submerged surfaces in an automated and multiplexed manner. The design of the microfluidic cell array (MFCA) 3D fluidics enables the printhead tip to be lowered into a liquid-filled well or dish and compressed against a surface to form a seal. The soft silicone tip of the printhead behaves like a gasket and is able to form a reversible seal by applying pressure or backing away. Other cells printing technologies such as pin or ink-jet printers are unable to print in submerged applications. Submerged surface printing is essential to maintain phenotypes of cells and to monitor these cells on a surface without disturbing the material surface characteristics. By printing onto submerged surfaces, cell microarrays are produced that allow for drug screening and cytotoxicity assessment in a multitude of areas including cancer, diabetes, inflammation, infections, and cardiovascular disease.
Collapse
|
41
|
Vaccine Delivery: Nanocomposite-Strengthened Dissolving Microneedles for Improved Transdermal Delivery to Human Skin (Adv. Healthcare Mater. 4/2014). Adv Healthc Mater 2014. [DOI: 10.1002/adhm.201470018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
42
|
Nanocomposite-strengthened dissolving microneedles for improved transdermal delivery to human skin. Adv Healthc Mater 2014; 3:555-64. [PMID: 24173960 DOI: 10.1002/adhm.201300312] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Indexed: 01/03/2023]
Abstract
Delivery of drugs and biomolecules into skin has significant advantages. To achieve this, herein, a nanomaterial-strengthened dissolving microneedle patch for transdermal delivery is reported. The patch comprises thousands of microneedles, which are composed of dissolving polymers, nanomaterials, and drug/biomolecules in their interior. With the addition of nanomaterials, the mechanical property of generally weak dissolving polymers can be dramatically improved without sacrificing dissolution rate within skin. In this experiments, layered double hydroxides (LDH) nanoparticles are incorporated into sodium carboxymethylcellulose (CMC) to form a nanocomposite. The results show that, by adding 5 wt% of LDH nanoparticles into CMC, the mechanical strength significantly increased. Small and densely packed CMC-LDH microneedles penetrate human and pig skin more reliably than pure CMC ones and attractively the nanocomposite-strengthened microneedles dissolve in skin and release payload within only 1 min. Finally, the application of using the nanocomposite-strengthened microneedle arrays is tested for in vivo vaccine delivery and the results show that significantly stronger antibody response could be induced when compared with subcutaneous injection. These data suggest that nanomaterials could be useful for fabricating densely packed and small polymer microneedles that have robust mechanical properties and rapid dissolution rates and therefore potential use in clinical applications.
Collapse
|
43
|
Improved polyvinylpyrrolidone microneedle arrays with non-stoichiometric cyclodextrin. J Mater Chem B 2014; 2:1699-1705. [DOI: 10.1039/c3tb21698e] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Improved polyvinylpyrrolidone (PVP) microneedle arrays can be fabricated by adding cyclodextrin (CD) to form PVP–CD inclusion complexes.
Collapse
|
44
|
Biased Cyclical Electrical Field Flow Fractionation for Separation of Sub 50 nm Particles. Anal Chem 2013; 85:11225-32. [DOI: 10.1021/ac401331z] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
45
|
Abstract
Diagnostic assays implemented in microfluidic devices have developed rapidly over the past decade and are expected to become commonplace in the next few years. Hundreds of microfluidics-based approaches towards clinical diagnostics and pathogen detection have been reported with a general theme of rapid and customizable assays that are potentially cost-effective. This chapter reviews microfluidics in molecular diagnostics based on application areas with a concise review of microfluidics in general. Basic principles of microfabrication are briefly reviewed and the transition to polymer fabricated devices is discussed. Most current microfluidic diagnostic devices are designed to target a single disease, such as a given cancer or a variety of pathogens, and there will likely be a large market for these focused devices; however, the future of molecular diagnostics lies in highly multiplexed microfluidic devices that can screen for potentially hundreds of diseases simultaneously.
Collapse
|
46
|
Characterization of Polymerized Liposomes Using a Combination of dc and Cyclical Electrical Field-Flow Fractionation. Anal Chem 2012; 84:8323-9. [DOI: 10.1021/ac301424b] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
47
|
Diffusion Split-Flow Thin Cell (SPLITT) system for protein separations. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 902:78-83. [DOI: 10.1016/j.jchromb.2012.06.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2011] [Revised: 06/18/2012] [Accepted: 06/24/2012] [Indexed: 11/28/2022]
|
48
|
|
49
|
A novel method for effective field measurements in electrical field-flow fractionation. Electrophoresis 2012; 33:1040-7. [DOI: 10.1002/elps.201100530] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
50
|
Characterization of a microscale thermal–electrical field-flow fractionation system. J Chromatogr A 2012; 1225:174-81. [DOI: 10.1016/j.chroma.2011.12.060] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2011] [Revised: 12/18/2011] [Accepted: 12/19/2011] [Indexed: 11/28/2022]
|