1
|
RevCore thrombectomy system for treatment of chronic left external and common iliac vein stent occlusion. J Vasc Surg Cases Innov Tech 2024; 10:101482. [PMID: 38633580 PMCID: PMC11022097 DOI: 10.1016/j.jvscit.2024.101482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 02/27/2024] [Indexed: 04/19/2024] Open
Abstract
In recent years, deep venous stenting has increasingly become a treatment strategy for post-thrombotic syndrome. Stent thrombosis can occur, resulting in symptom recurrence despite medical therapy, and there are few options available for durable stent patency restoration. We present a case of a 50-year-old male with prior iliocaval reconstruction that experienced recurrent left lower extremity swelling secondary to occlusion of left external iliac and common iliac vein stents during follow-up. Mechanical thrombectomy with the RevCore System and angioplasty was performed. One month later, the patient demonstrated widely patent bilateral iliac vein stents and complete symptomatic resolution. The RevCore System is a feasible alternative for treatment of chronic in-stent thrombosis.
Collapse
|
2
|
Early results of transcatheter electrosurgical aortic septotomy for endovascular repair of chronic dissecting aortoiliac aneurysms. J Vasc Surg Cases Innov Tech 2024; 10:101467. [PMID: 38591014 PMCID: PMC10999806 DOI: 10.1016/j.jvscit.2024.101467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 02/22/2024] [Indexed: 04/10/2024] Open
Abstract
Objective Endovascular repair of chronic dissecting aortoiliac aneurysms is challenging given the rigid septum, compressed true lumen (TL), and target vessels frequently originating in the false lumen. We have used transcatheter electrosurgical aortic septotomy (TEAS) before stent graft implantation under intravascular ultrasound (IVUS) and fusion guidance. The purpose of this study is to assess the outcomes of TEAS during complex endovascular repair of dissecting aneurysms. Methods From 2021 to 2023, 17 patients underwent TEAS. The primary end point was technical success, with secondary end points of proximal and distal seals, target vessel instability, aortic and iliac TL and cross-sectional area (CSA) expansion, and aortic-related death. During the procedure, the aortic septum is crossed through a pre-existing entry or via electrocautery-activated 0.018-in. Astato XS20 wire (Asahi-Intecc) under IVUS and fusion guidance. The penetrated wire is then snared in the false lumen and pulled through the ipsilateral femoral access. A 1-cm length of the middle of the Astato wire coating is kinked in a three-sided polygonal configuration, denuded the inner surface of the wire using a no. 15 blade, and positioned at the apex of the septum. Both ends of the Astato wire are insulated with 0.018-in. microcatheters, and the back end of the wire is denuded and connected to cautery. Gentle traction is applied to the wire, and short bursts of electrocautery cutting are applied at 60 to 80 W. Results The technical success of the septotomy was 100%. No incidence of visceral or lower extremity malperfusion, vascular injury, or distal embolization occurred. Of the 17 patients, 4 underwent thoracic endovascular aneurysm repair, 2 underwent endovascular aortic repair, and 11 underwent fenestrated/branched endovascular aneurysm repair after septotomy. All target vessels were successfully stented. A distal landing zone seal with exclusion of the false lumen was achieved in 16 of the 17 patients (94.1%). One patient required embolization of the false lumen of the celiac artery after septotomy. The TL mean diameter and CSA of the descending thoracic aorta after septotomy was expanded by 7.01 ± 1.9 mm (relative mean diameter expansion, 42.3%; P < .0001) and 2.71 ± 0.4 cm2 (relative mean CSA expansion, 57.3%, P<.0001). For patients who required septotomy through the common iliac arteries, the mean TL was expanded by 8.1 ± 3.7 mm (relative mean diameter expansion, 76%; P < .0001) and 1.76 ± 0.91 cm2 (relative mean CSA expansion, 209%; P < .0001). The 1-year freedom from target vessel instability was 91%. Conclusions The use of IVUS and fusion-guided TEAS offers a promising technique to facilitate TL expansion and false lumen exclusion in chronic dissecting aortic aneurysms before repair. The durability and long-term outcomes of this technique in a larger cohort remain to be elucidated.
Collapse
|
3
|
Up and over staged endoconduit technique for endovascular aortic aneurysm repair. J Vasc Surg Cases Innov Tech 2024; 10:101449. [PMID: 38510089 PMCID: PMC10951543 DOI: 10.1016/j.jvscit.2024.101449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2024] Open
Abstract
Adverse iliofemoral anatomy can preclude complex endovascular aortic aneurysm repair. This study aims to describe the "up-and-over" staged endoconduit technique to improve access and avoid vascular injury before complex endovascular aneurysm repair. A staged procedure for complex endovascular aortic aneurysm repair is performed using an endoconduit (W.L. Gore & Associates). After obtaining contralateral femoral access, the extension of iliofemoral disease is assessed using angiography. The endoconduit is advanced "up and over" the aortic bifurcation and delivered percutaneously into the common femoral artery to treat a diseased access site and maintain intact the ipsilateral femoral access for future stent graft deployment. Internal iliac artery patency is maintained when feasible. During complex aneurysm repair, the endoconduit is accessed directly under ultrasound guidance using sequential dilation to avoid vascular injury. PerClose sutures (Abbott Vascular) are used to close the endoconduit femoral access site. This study found that staged "up and over" endoconduit creation is a useful technique before complex endovascular aneurysm repair in patients with adverse iliofemoral anatomy. Avoiding accessing the main femoral access site during the first stage prevents vascular or access site injuries and allows for both iliac and femoral disease to be addressed.
Collapse
|
4
|
Practice Patterns of Antiplatelet and Anticoagulant Therapy After Fenestrated/Branched Endovascular Aortic Repair. J Vasc Surg 2024:S0741-5214(24)01220-5. [PMID: 38796031 DOI: 10.1016/j.jvs.2024.05.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 04/02/2024] [Accepted: 05/20/2024] [Indexed: 05/28/2024]
Abstract
OBJECTIVE Antiplatelet and/or anticoagulant therapy are commonly prescribed after fenestrated/branched endovascular aortic repair (F/BEVAR). However, the optimal regimen remains unknown. We sought to characterize practice patterns and outcomes of antiplatelet and anticoagulant use in patients who underwent F/BEVAR. METHODS Consecutive patients enrolled (2012-2023) as part of the United States Aortic Research Consortium (US-ARC) from ten independent physician-sponsored investigational device exemption (PS-IDE) studies were evaluated. The cohort was characterized by medication regimen on discharge from index F/BEVAR: 1. Aspirin alone OR p2y12 alone (single-antiplatelet therapy, SAPT), 2. Anticoagulant Alone, 3. Aspirin+p2y12 (dual-antiplatelet therapy, DAPT), 4. Aspirin+anticoagulant OR p2y12+anticoagulant (SAPT+Anticoagulant), 5. Aspirin+p2y12+anticoagulant (triple therapy, TT), and 6. No Therapy. Kaplan-Meier analysis and Cox proportional hazards modeling were used to compare 1-year outcomes including survival, target artery patency, freedom from bleeding complication, freedom from all reinterventions, and freedom from stent-specific reintervention. RESULTS Of the 1525 patients with complete exposure and outcome data, 49.6% were discharged on DAPT, 28.8% on SAPT, 13.6% on SAPT+Anticoagulant, 3.2% on TT, 2.6% on Anticoagulant Alone, and 2.2% on No Therapy. Discharge medication regimen was not associated with differences in 1-year survival, bleeding complications, composite reintervention rate, or stent-specific reintervention rate. However, there was a significant difference in 1-year target artery patency. On multivariable analysis comparing to SAPT, DAPT conferred a lower hazard of loss of target artery patency (HR 0.48, 95% CI 0.27-0.84, p=0.01). On sub-analyses of renal stents alone or visceral stents alone, DAPT no longer had a significantly lower hazard of loss of target artery patency (Renal: HR 0.66, 95% CI 0.35-1.27, p=0.22. Visceral: HR 0.31, 95% 0.05-1.9, p=0.21). Lastly, duration of DAPT therapy (1 month, 6 months, or 1 year) did not significantly affect target artery patency. CONCLUSIONS Practice patterns for antiplatelet and anticoagulant regimens after F/BEVAR vary widely across the US-ARC. There were no differences in bleeding complications, survival or reintervention rates among different regimens, but higher branch vessel patency was noted in the DAPT cohort. These data suggest there is a benefit in DAPT therapy. However, the generalizability of this finding is limited by the retrospective nature of this data, and the clinical significance of this finding is unclear, as there is no difference in survival, bleeding, or reintervention rates amongst the different regimens. Hence, an "optimal" regimen, including the duration of such regimen, could not be clearly discerned. This suggests equipoise for a randomized trial, nested within this cohort, to identify the most effective antiplatelet/anticoagulant regimen for the growing number of patients being treated globally with F/BEVAR.
Collapse
|
5
|
Impact of chronic kidney disease and end-stage renal disease on outcomes after complex endovascular and open aortic aneurysm repair. J Vasc Surg 2024; 79:1034-1043. [PMID: 38157993 DOI: 10.1016/j.jvs.2023.12.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/21/2023] [Accepted: 12/22/2023] [Indexed: 01/03/2024]
Abstract
OBJECTIVE Chronic kidney disease (CKD) and end-stage renal disease are traditionally associated with worse outcomes after endovascular aortic repair (EVAR) and open aneurysm repair (OAR) of abdominal aortic aneurysms (AAAs). However, there needs to be more data on complex AAA repair involving the aorta's visceral segment. This study stratifies complex AAA repair outcomes by CKD severity and dialysis dependence. METHODS All patients undergoing elective OAR and fenestrated/branched EVAR (F-BEVAR) for complex AAA with preoperative renal function data captured by the Vascular Quality Initiative between January 2003 and September 2020 were analyzed. Patients were stratified by CKD class as follows: normal/mild (CKD 1 and 2), moderate (CKD class 3a), moderate to severe (CKD 3b), severe (CKD class 4 and 5), and dialysis. Only patients with clamp sites above one of the renal arteries were included for complex OAR. For F-BEVAR, patients with proximal landing zones below zone 5 (above celiac artery) were included, and distal landing zones between zones 1 and 5 were excluded. Primary outcomes were perioperative and 1-year mortality. Predictors of mortality were identified by Cox multivariate regression models. RESULTS We identified 7849 elective complex AAA repairs: 4230 (54%) complex OARs and 3619 (46%) F-BEVARs. Most patients were White (89%) and male (74%), with an average age of 72 ± 8 years. The patients who underwent F-BEVAR were older and had more comorbidities. Elective F-BEVAR for complex AAA started in 2012 and increased from 1.4% in 2012 to 58% in 2020 (P < .001). The OAR cohort had more perioperative complications, but less 1-year mortality. The normal/mild CKD cohort had the highest 1-year survival compared with other groups after both complex OAR and F-BEVAR. On Cox regression analysis, when compared with CKD 1-2, worsening CKD stage (CKD 3b: hazard ratio [HR], 2.5; 95% confidence interval [CI], 1.82-3.40; P < .001; CKD 4-5: HR, 1.9; 95% CI, 1.16-3.26; P = .011; and dialysis: HR, 4.4; 95% CI, 2.53-7.72; P < .001) were independently associated with 1-year survival after F-BEVAR. After complex OAR, worsening CKD stage but not dialysis was associated with 1-year mortality compared with CKD 1-2 (CKD 3b: HR, 1.6; 95% CI, 1.13-2.35; P = .009; CKD 4-5: HR, 3.4; 95% CI, 2.03-5.79; P < .001). CONCLUSIONS CKD severity is an essential predictor of perioperative and 1-year mortality after complex AAA repair, irrespective of the treatment modality, which may reflect the natural history of CKD. Consideration should be given to raising the threshold for elective AAA repair in patients with moderate to severe CKD and end-stage renal disease, given the high 1-year mortality rate.
Collapse
MESH Headings
- Humans
- Male
- Middle Aged
- Aged
- Aged, 80 and over
- Risk Factors
- Blood Vessel Prosthesis Implantation/adverse effects
- Treatment Outcome
- Endovascular Procedures/adverse effects
- Time Factors
- Kidney Failure, Chronic/complications
- Kidney Failure, Chronic/diagnosis
- Kidney Failure, Chronic/therapy
- Renal Insufficiency, Chronic/complications
- Renal Insufficiency, Chronic/diagnosis
- Renal Insufficiency, Chronic/therapy
- Aortic Aneurysm, Abdominal/complications
- Aortic Aneurysm, Abdominal/diagnostic imaging
- Aortic Aneurysm, Abdominal/surgery
- Retrospective Studies
Collapse
|
6
|
Impact of a Quality Improvement Initiative on Medical Management of Veterans With Peripheral Artery Disease. Am J Cardiol 2024; 221:44-49. [PMID: 38636628 DOI: 10.1016/j.amjcard.2024.03.044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 03/15/2024] [Indexed: 04/20/2024]
Abstract
Guideline-directed medical therapy (GDMT) for peripheral artery disease (PAD) remains severely underused. Prevention of Amputation in Veterans Everywhere (PAVE) is a screening program designed to prevent or delay major lower extremity amputation. This study aimed to determine whether diagnosis of PAD through the PAVE program improves the prescription of GDMT in veterans with asymptomatic PAD. Patients enrolled into the PAVE program from our institution from 2020 to 2021 were included. Patients with an abnormal ankle-brachial index (ABI), defined as ABI <0.9 or >1.2, were selected for further analysis. Primary outcome was adherence to GDMT, following class I and class IIa recommendations. Secondary outcomes included changes in low-density lipoprotein (LDL), blood pressure, and hemoglobin A1c (HbA1c). A total of 6,313 patients were enrolled into the PAVE program between 2020 and 2021. Of these, 211 had abnormal ABI and were included in our analysis. With enrollment into PAVE, there was significant increase in the prescription of aspirin (74.4% vs 64.9%, p = 0.044) and statins (91.5% vs 82%, p = 0.006). The overall adherence to GDMT significantly increased (56.9% vs 38.9%, p <0.001). The number of patients needed to enroll in PAVE to improve GDMT adherence is 5.6 (95% confidence interval 3.6 to 12.3). Patients enrolled into PAVE program saw significant decreases in HbA1c, with mean decrease of 0.3 (p = 0.012) and a decrease in LDL, with a mean decrease of 6.2 (p = 0.01). In conclusion, enrollment into an amputation prevention program secondarily increased adherence to GDMT, driven by increases in the prescription of statins and aspirin, with resulting decreases in HbA1c and LDL.
Collapse
|
7
|
Prospective randomized pilot trial comparing prophylactic vs therapeutic cerebrospinal fluid drainage during complex endovascular thoracoabdominal aortic aneurysm repair. J Vasc Surg 2024:S0741-5214(24)00429-4. [PMID: 38614137 DOI: 10.1016/j.jvs.2024.02.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/07/2024] [Accepted: 02/09/2024] [Indexed: 04/15/2024]
Abstract
BACKGROUND Endovascular techniques have transformed the management of thoracoabdominal aortic aneurysms (TAAAs). However, spinal cord ischemia (SCI) remains a prevalent and devastating complication. Prophylactic drainage of cerebrospinal fluid (CSF) is among the proposed strategies for prevention of SCI. Although prophylactic CSF drainage is widely used and conceptually attractive, prophylactic CSF drains have not been demonstrated to definitively prevent the occurrence nor mitigate the severity of SCI in endovascular TAAA repair. Whether or not outcomes of prophylactic drains are superior to therapeutic drains remains unknown. This pilot study was performed to determine the feasibility of a randomized clinical trial designed to investigate the role of prophylactic vs therapeutic CSF drains in the prevention of SCI in patients undergoing endovascular TAAA repair using branched and fenestrated endovascular aortic repair (FBEVAR). METHODS This was a prospective multicenter randomized pilot clinical trial conducted at The University of Alabama at Birmingham and The University of Massachusetts. Twenty patients were enrolled and randomized to either the prophylactic drainage or therapeutic drainage groups, prior to undergoing FBEVAR for extensive TAAAs and arch aortic aneurysms. This was a pilot feasibility study that was not powered to detect statistical differences in clinical outcomes. The primary outcome was feasibility of randomization and compliance with a shared lumbar drain protocol. Secondary outcomes included rate of drain complications and SCI. RESULTS Twenty patients were enrolled and successfully randomized, without any crossovers, to either the control cohort (n = 10), without prophylactic drains, or the experimental cohort (n = 10), with prophylactic drains. There were no differences in age, comorbidities, or history of prior aortic surgery across the cohorts. All patients were treated with FBEVAR. Aneurysm classifications were as follows: Extent I (10%), Extent II (50%), Extent III (35%), and Extent IV (5%). The average length of aortic coverage was 207 ± 21.6 mm. The length of aortic coverage did not vary across cohorts, nor did procedural times or blood loss volume. Compliance with the SCI prevention protocol was 100% across both groups. Within the prophylactic drain cohort, one patient experienced an adverse event related to lumbar drain placement, manifested as an epidural hematoma requiring laminectomy, without neurologic deficit (n = 1/10; 10%). There was one SCI event (n = 1/20; 5%), which occurred in the prophylactic drain cohort on postoperative day 9 following an episode of hypotension related to a gastrointestinal bleed. CONCLUSIONS The role of prophylactic CSF drains for the prevention of SCI following endovascular TAAA repair is a topic of ongoing research, with many current practices based on expert opinion and experience, rather than rigorous scientific data. This study demonstrates the feasibility of a multicenter randomized clinical trial to evaluate the role of prophylactic vs therapeutic CSF drains in the prevention of SCI in patients undergoing endovascular TAAA repair.
Collapse
|
8
|
Transcatheter electrosurgical septotomy technique for chronic postdissection aortic aneurysms. J Vasc Surg Cases Innov Tech 2024; 10:101402. [PMID: 38304296 PMCID: PMC10830870 DOI: 10.1016/j.jvscit.2023.101402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2024] Open
Abstract
Aortic dissection often results in chronic aneurysmal degeneration due to progressive false lumen expansion. Thoracic endovascular aortic repair and other techniques of vessel incorporation such as fenestrated-branched or parallel grafts have been increasingly used to treat chronic postdissection aneurysms. True lumen compression or a vessel origin from the false lumen can present considerable technical challenges. In these cases, the limited true lumen space can result in inadequate stent graft expansion or restrict the ability to reposition the device or manipulate catheters. Reentrance techniques can be used selectively to assist with target vessel catheterization. Transcatheter electrosurgical septotomy is a novel technique that has evolved from the cardiology experience with transseptal or transcatheter aortic valve procedures. This technique has been applied in select patients with chronic dissection to create a proximal or distal landing zone, disrupt the septum in patients with an excessively compressed true lumen, or connect the true and false lumen in patients with vessels that have separate origins. In the present report, we summarize the indications and technical pitfalls of transcatheter electrosurgical septotomy in patients treated by endovascular repair for chronic postdissection aortic aneurysms.
Collapse
|
9
|
The addition of a leaded arm sleeve to leaded aprons further decreases operator upper outer quadrant chest wall radiation dose during fluoroscopically guided interventions. J Vasc Surg 2024; 79:948-953. [PMID: 38040201 DOI: 10.1016/j.jvs.2023.11.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/20/2023] [Accepted: 11/23/2023] [Indexed: 12/03/2023]
Abstract
OBJECTIVE Breast cancer most commonly occurs in the upper outer quadrant (UOQ) chest wall (CW). The effectiveness of routine leaded aprons to protect this region of the body in interventionalists during fluoroscopically guided interventions (FGIs) is unknown. Given the high lifetime attributable risks of prolonged occupational exposure to ionizing radiation and the increasing number of practicing female vascular surgeons and interventionalists, we sought to determine if the use of a leaded arm shield would offer additional protection to the lateral CW and axilla in operators compared with routine leaded aprons. METHODS Effectiveness of leaded sleeves in attenuating radiation dose to the axilla and UOQ was evaluated in clinical practice and simulated scenarios. In the clinical setting, optically stimulated luminescence nanoDot detectors were placed at the UOQ lateral CW position, both over and under a standard leaded apron vest with and without the addition of an antimony/bismuth Enviro-Lite sleeve on two vascular surgeons performing FGIs. In the simulation, nanoDots were similarly placed on an anthropomorphic phantom positioned to represent a primary operator performing right femoral access. Fluorography was performed on 12-inch-thick acrylic scatter phantom at 80 kVp for an exposure of 3 Gy reference air kerma. Experiments were done with and without the sleeve. Paired Wilcoxon and χ2 tests were performed to identify the statistical significance of radiation attenuation. RESULTS Operator UOQ CW dose was measured during 61 FGIs: 33 cases (54%) with and 28 cases (46%) without the sleeve. Median procedure reference air kerma and fluoroscopy time was 180 mGy (interquartile range [IQR], 85-447 mGy) and 21 minutes (IQR, 11-39 minutes) when the sleeve was worn vs 100 mGy (IQR, 67-270 mGy) and 11 minutes (IQR, 6.3-25 minutes) without the sleeve. Radiation dose to the operator's UOQ was reduced by 96% (IQR, 85%-96%) when the sleeve was present and by 62% (IQR, 44%-82%; P < .001) without the sleeve. In the simulated setting, the sleeve reduced the radiation dose to the UOQ compared with the apron alone (96% vs 67%; P < .001). CONCLUSIONS Routine leaded aprons do attenuate the majority of UOQ chest wall radiation dose; however, the addition of a lead-equivalent sleeve further significantly reduces this dose. Because this area of the body has a high incidence of cancer formation, additional protection, especially to female interventionalists, seems prudent. Vascular surgeons should consider using a protective sleeve with their personal protective equipment when performing complex fluoroscopically guided procedures.
Collapse
|
10
|
Impact of head and neck radiation on long-term outcomes after carotid revascularization. J Vasc Surg 2024:S0741-5214(24)00928-5. [PMID: 38570175 DOI: 10.1016/j.jvs.2024.03.441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/21/2024] [Accepted: 03/25/2024] [Indexed: 04/05/2024]
Abstract
OBJECTIVE Radiation-induced carotid artery stenosis (RICS) is a well-described phenomenon seen after head and neck cancer radiation. Previously published literature suggests that, compared with atherosclerotic disease, RICS may result in worse long-term outcomes and early restenosis. This study aims to evaluate the effect of radiation on long-term outcomes after various carotid revascularization techniques using a multi-center registry database. METHODS Patients in the Society for Vascular Surgery (SVS) Vascular Quality Initiative (VQI) registry for carotid artery intervention (carotid endarterectomy [CEA]; transfemoral carotid artery stenting [CAS]; transcarotid artery revascularization [TCAR]), who are 65 years or older were included in the study. VQI Vascular Implant Surveillance and Interventional Outcomes Network (VISION) Medicare-linked database was used to obtain long-term procedure-specific outcomes. Primary endpoints were 3-year death, stroke, and reintervention. We performed propensity matching between patients with prior radiation and those without. Kaplan-Meier analysis and a multivariate logistic regression model were used to analyze the outcome variables. RESULTS A total of 56,472 patients had undergone carotid revascularization (CEA, n = 48,307; TCAR, n = 4593; CAS, n = 3572), 1244 patients with prior radiation and 54,925 patients without prior radiation. The prior radiation group was more likely to be male (71.9% vs 60.3%; P < .01), to receive a stent (47.5% vs 13.5%; P < .01), and to be on P2Y12 inhibitor (55.2% vs 38.3%; P < .01). Propensity matching was performed on 1223 patients (CEA, n = 655; TCAR, n = 292; CAS, n = 287). There were no significant differences in 30-day outcomes for death, stroke, or major adverse cardiovascular events for all three procedures. The prior radiation group had higher rates of cranial nerve injury (3.7% vs 1.8%; P = .04) and 90-day readmission (23.5% vs 18.3%; P = .01) after CEA. For long-term outcomes, prior radiation significantly increased mortality risk for CEA and CAS (hazard ratio [HR], 1.77; 95% confidence interval [CI], 1.38-2.27 and HR, 1.56; 95% CI, 1.02-2.36, respectively). The 3-year risk of stroke for CEA in radiated patients was also significantly higher (HR, 1.47; 95% CI, 1.03-2.09) compared with non-radiated patients. Prior radiation did not significantly affect death and stroke in patients undergoing TCAR. Prior radiation also did not impact the rates of short and long-term reintervention after CEA, CAS, or TCAR. CONCLUSIONS Prior head and neck radiation significantly increases the risk for mortality and stroke for CEA and the risk for mortality after CAS. Long-term outcomes for TCAR are not significantly affected by prior radiation. TCAR may be the preferred treatment modality for patients with radiation-induced carotid stenosis.
Collapse
|
11
|
Long-term outcomes of staged iliofemoral endoconduits prior to complex endovascular aortic aneurysm repair. J Vasc Surg 2024:S0741-5214(24)00276-3. [PMID: 38336105 DOI: 10.1016/j.jvs.2024.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 01/22/2024] [Accepted: 02/01/2024] [Indexed: 02/12/2024]
Abstract
OBJECTIVE Adverse iliofemoral anatomy may preclude complex endovascular aortic aneurysm repair (EVAR). In our practice, staged iliofemoral endoconduits (ECs) are planned prior to complex EVAR to improve vascular access and decrease operative time while allowing the stented vessel to heal. This study describes the long-term results of iliofemoral ECs prior to complex EVAR. METHODS Between 2012 and 2023, 59 patients (44% male; median age, 75 ± 6 years) underwent ECs before complex EVAR using self-expanding covered stents (Viabahn). For common femoral artery (CFA) disease, ECs were delivered percutaneously from contralateral femoral access and extended into the CFA to preserve the future access site for stent graft delivery. Internal iliac artery patency was maintained when feasible. During complex EVAR, the EC extended into the CFA was directly accessed and sequentially dilated until it could accommodate the endograft. Technical success was defined as successful access, closure, and delivery of the endograft during complex EVAR. Endpoints were vascular injury or EC disruption, secondary interventions, and EC patency. RESULTS Unilateral EC was performed in 45 patients (76%). ECs were extended into the CFA in 21 patients (35%). Median diameters of the native common iliac, external iliac, and CFA were 7 mm (interquartile range [IQR], 6-8 mm), 6 mm (IQR, 5-7 mm), and 6 mm (IQR, 6-7 mm), respectively. Internal iliac artery was inadvertently excluded in 10 patients (17%). Six patients (10%) had an intraoperative vascular injury during the EC procedure, and six patients (10%) had EC disruption during complex EVAR, including five EC collapses requiring re-stenting and one EC fracture requiring open cut-down and reconstruction with patch angioplasty. In 23 patients (39%), 22 Fr OD devices were used; 20 Fr were used in 22 patients (37%), and 18 Fr in 14 patients (24%). Technical success for accessing EC was 89%. There was no difference in major adverse events at 30 days between the iliac ECs and iliofemoral ECs. Primary patency by Kaplan-Meier estimates at 1, 3, and 5 years were 97.5%, 89%, and 82%, respectively. There was no difference in primary patency between iliac and iliofemoral ECs. Six secondary interventions (10%) were required. The mean follow-up was 34 ± 27 months; no limb loss or amputations occurred during the follow-up. CONCLUSIONS ECs improve vascular access, and their use prior to complex EVAR is associated with low rates of vascular injury, high technical success, and optimal long-term patency. Complex EVAR procedures can be performed percutaneously by accessing the EC directly under ultrasound guidance and using sequential dilation to avoid EC disruption.
Collapse
|
12
|
Impact of routine surveillance duplex ultrasound and subsequent reintervention after superficial femoral artery stenting. J Vasc Surg 2024; 79:102-110. [PMID: 37704092 DOI: 10.1016/j.jvs.2023.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 09/05/2023] [Accepted: 09/07/2023] [Indexed: 09/15/2023]
Abstract
OBJECTIVE Superficial femoral artery (SFA) stenting is a common treatment for peripheral artery disease. It is effective in the short term; however, in-stent restenosis (ISR) limits long-term success. Surveillance with duplex ultrasound (DUS) can identify patients who develop ISR leading to early reintervention, but data to support this practice is sparce. The purpose of this study was to evaluate whether surveillance and subsequent reintervention improves outcomes in patients with SFA stents. METHODS A single-center, retrospective study was performed with patients undergoing SFA stenting between 2005 and 2020 who had a follow-up with DUS. Five groups were identified based on the presence of ISR on DUS (ISR vs no ISR [NISR]), recurrence of symptoms (symptomatic [SX] vs asymptomatic [ASX]), and if any reintervention was performed (reintervention [R] vs no reintervention [NR]): (1) ISR+SX+R; (2) ISR+SX+NR; (3) ISR+ASX+R; (4) ISR+ASX+NR; and (5) NISR+NR. The primary endpoint was amputation-free survival, and the secondary endpoint was patency. Predictors of mortality and surveillance were identified by multivariable logistic regressions and Cox multivariate regression models. Survival curves were presented as Kaplan-Meier plots using log-rank test for subgroup comparison. RESULTS Two hundred fifty-seven patients were included in the analysis. The indication for intervention was claudication in 28% and chronic limb-threatening ischemia in 72%. A total of 161 patients (63%) underwent reintervention for ISR. Of patients who had restenosis on DUS, those who were symptomatic and did not undergo reintervention (ISR+SX+NR) did the worst, with 50% amputation rate. In contrast, those who were asymptomatic but did undergo reintervention (ISR+ASX+R) had the lowest amputation rate of 13%. Active smoking was a predictor of both loss of patency and amputation (1.72; 95% confidence interval [CI], 1.00-2.98; P = .050; 3.55; 95% CI, 1.53-8.25; P = .003). Post procedure dual antiplatelet therapy had a positive association with limb salvage (hazard ratio [HR], 0.23; 95% CI, 0.09-0.58; P = .001), whereas diabetes (HR, 2.61; 95% CI, 1.21-6.01; P = .019), stent occlusion (HR, 17.0; 95% CI, 5.93-63.1; P < .001), and chronic limb-threatening ischemia presentations (HR, 4.31; 95% CI, 1.86-11.7; P=.002) were negatively associated with limb salvage. CONCLUSIONS Routine surveillance DUS and subsequent reintervention on ISR after SFA stenting is associated with improved patency and amputation-free survival. Surveillance DUS should be routine for patients after stenting, with reintervention strongly considered if ISR is identified for both symptomatic and asymptomatic.
Collapse
|
13
|
Abstract
Failed fenestrated-branched endovascular aortic repair (F-BEVAR) requiring a redo F-BEVAR is a rare event. In this study, we report 2 cases of a failed F-BEVAR secondary to a type IIIb endoleak from tears on the fabric graft successfully treated with redo F-BEVAR. This is a technically challenging procedure that requires meticulous planning, advanced imaging technologies and experienced operators. Redo F-BEVAR appears to be a feasible and safe treatment option. However, larger series and long-term follow-up are needed to confirm effectiveness and durability.
Collapse
|
14
|
Severity of acute kidney injury is associated with decreased survival after fenestrated and branched endovascular aortic aneurysm repair. J Vasc Surg 2023; 78:892-901. [PMID: 37330702 DOI: 10.1016/j.jvs.2023.05.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 05/19/2023] [Accepted: 05/22/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE Acute kidney injury (AKI) occurs frequently in complex aortic surgery and has been implicated in perioperative and long-term survival. This study sought to characterize the relationship between AKI severity and mortality after fenestrated and branched endovascular aortic aneurysm repair (F/B-EVAR). METHODS Consecutive patients enrolled by the US Aortic Research Consortium in 10, prospective, nonrandomized, physician-sponsored investigational device exemption studies evaluating F/B-EVAR, between 2005 and 2023, were included in this study. Perioperative AKI during hospitalization was defined by and staged using the 2012 Kidney Disease Improving Global Outcomes criteria. Determinants of AKI were evaluated with backward stepwise mixed effects multivariable ordinal logistic regression. Survival was analyzed with conditionally adjusted survival curves and backward stepwise mixed effects Cox proportional hazards modelling. RESULTS In the study period, 2413 patients with a median (interquartile range [IQR]) age of 74 years (IQR, 69-79 years) underwent F/B-EVAR. The median follow-up duration was 2.2 years (IQR, 0.7-3.7 years). The median baseline estimated glomerular filtration rate (eGFR) and creatinine were 68 mL/min/1.73 m2 (IQR, 53-84 mL/min/1.73 m2) and 1.1 mg/dL (IQR, 0.9-1.3 mg/dL), respectively. Stratification of AKI identified 316 patients (13%) with stage 1 injury, 42 (2%) with stage 2 injury, and 74 (3%) with stage 3 injury. Renal replacement therapy was initiated during the index hospitalization in 36 patients (1.5% of cohort, 49% of stage 3 injuries). Thirty-day major adverse events were associated with AKI severity (all P ≤ .0001). Multivariable predictors of AKI severity included baseline eGFR (proportional odds ratio, 0.9 per 10 mL/min/1.73 m2 [95% confidence interval (CI), 0.85-0.95 per 10 mL/min/1.73 m2]; P < .0001), baseline serum hematocrit (0.58 per 10% [95% CI, 0.48-0.71 per 10%]; P < .0001), renal artery technical failure during aneurysm repair (3 [95% CI,1.61-5.72]; P = .0006), and total operating time (1.05 per 10 minutes [95% CI, 1.04-1.07 per 10 minutes]; P < .0001). One-year unadjusted survivals for AKI severity strata were 91% (95% CI, 90%-92%) for no injury, 80% (95% CI, 76%-85%) for stage 1 injury, 72% (95% CI, 59-87%) for stage 2 injury, and 46% (95% CI, 35-59%) for stage 3 injury (P<.0001). Multivariable determinants of survival included AKI severity (stage 1, hazard ratio [HR], 1.6 [95% CI, 1.3-2]); stage 2, HR, 2.2 [95% CI, 1.4-3.4]); stage 3 HR, 4 [95% CI, 2.9-5.5]; P < .0001), decreased eGFR (HR, 1.1 [95% CI, 0.9-1.3]; P = .4), patient age (HR, 1.6 per 10 years [95% CI, 1.4-1.8 per 10 years]; P < .0001), baseline chronic obstructive pulmonary disease (HR, 1.5 [95% CI, 1.3-1.8]; P < .0001), baseline congestive heart failure (HR, 1.7 [95% CI, 1.6-2.1]; P < .0001), postoperative paraplegia (HR, 2.1 [95% CI, 1.1-4]; P = .02), and procedural technical success (HR, 0.6 [95% CI, 0.4-0.8]; P = .003). CONCLUSIONS AKI, as defined by the 2012 Kidney Disease Improving Global Outcomes criteria, occurred in 18% of patients after F/B-EVAR. Greater severity of AKI after F/B-EVAR was associated with decreased postoperative survival. The predictors of AKI severity identified in these analyses suggest a role for improved preoperative risk mitigation and staging of interventions in complex aortic repair.
Collapse
|
15
|
Multicenter trans-Atlantic experience with fenestrated-branched endovascular aortic repair of chronic post-dissection thoracoabdominal aortic aneurysms. J Vasc Surg 2023; 78:854-862.e1. [PMID: 37321524 DOI: 10.1016/j.jvs.2023.05.053] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 05/22/2023] [Accepted: 05/23/2023] [Indexed: 06/17/2023]
Abstract
OBJECTIVE This multicenter international study aimed to describe outcomes of fenestrated-branched endovascular aortic repairs (FB-EVAR) in a cohort of patients treated for chronic post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs). METHODS We reviewed the clinical data of all consecutive patients treated by FB-EVAR for repair of extent I to III PD-TAAAs in 16 centers from the United States and Europe (2008-2021). Data were extracted from institutional prospectively maintained databases and electronic patient records. All patients received off-the-shelf or patient-specific manufactured fenestrated-branched stent grafts. Endpoints were any cause mortality and major adverse events at 30 days, technical success, target artery (TA) patency, freedom from TA instability, minor (endovascular with <12 Fr sheath) and major (open or ≥12 Fr sheath) secondary interventions, patient survival, and freedom from aortic-related mortality (ARM). RESULTS A total of 246 patients (76% male; median age, 67 years [interquartile range, 61-73 years]) were treated for extent I (7%), extent II (55%), and extent III (35%) PD-TAAAs by FB-EVAR. The median aneurysm diameter was 65 mm (interquartile range, 59-73 mm). Eighteen patients (7%) were octogenarians, 212 (86%) were American Society of Anesthesiologists class ≥3, and 21 (9%) presented with contained ruptured or symptomatic aneurysms. There were 917 renal-mesenteric vessels targeted by 581 fenestrations (63%) and 336 directional branches (37%), with a mean of 3.7 vessels per patient. Technical success was 96%. Mortality and rate of major adverse events at 30 days was 3% and 28%, including disabling complications such as new onset dialysis in 1%, major stroke in 1%, and permanent paraplegia in 2%. Mean follow-up was 24 months. Kaplan-Meier (KM) estimated patient survival at 3 and 5 years was 79% ± 6% and 65% ± 10%. KM estimated freedom from ARM was 95% ± 3% and 93% ± 5% at the same intervals. Unplanned secondary interventions were needed in 94 patients (38%), including minor procedures in 64 (25%) and major procedures in 30 (12%). There was one conversion to open surgical repair (<1%). KM estimated freedom from any secondary intervention was 44% ± 9% at 5 years. KM estimated primary and secondary TA patency were 93% ± 2% and 96% ± 1% at 5 years, respectively. CONCLUSIONS FB-EVAR for chronic PD-TAAAs was associated with high technical success and a low rate of mortality (3%) and disabling complications at 30 days. Although the procedure is effective in the prevention of ARM, patient survival was low at 5 years (65%), likely due to the significant comorbidities in this cohort of patients. Freedom from secondary interventions at 5 years was 44%, although most procedures were minor. The significant rate of reinterventions highlights the need for continued patient surveillance.
Collapse
|
16
|
Mid-term Renal and Mesenteric Artery Outcomes During Fenestrated and Branched Endovascular Aortic Repair for Complex Abdominal and Thoracoabdominal Aortic Aneurysms in the United States Aortic Research Consortium. Ann Surg 2023; 278:e893-e902. [PMID: 37051912 DOI: 10.1097/sla.0000000000005859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
OBJECTIVE To report mid-term outcomes of renal-mesenteric target arteries (TAs) after fenestrated-branched endovascular aortic repair (FB-EVAR) of complex abdominal and thoracoabdominal aortic aneurysm. BACKGROUND TA instability (TAI) is the most frequent indication for reintervention after FB-EVAR. METHODS Data from consecutive patients enrolled in 9 prospective nonrandomized physician-sponsored investigational device exemption studies between 2005 and 2020 were reviewed. TA outcomes through 5 years of follow-up were analyzed for vessels incorporated by fenestrations or directional branches (DBs), including TA patency, endoleak, integrity failure, reintervention, and instability. RESULTS A total of 1681 patients had 6349 renal-mesenteric arteries were targeted using 3720 fenestrations (59%), 2435 DBs (38%), and 194 scallops (3%). Mean follow was 23 ± 21 months. At 5 years, TAs incorporated by fenestrations had higher primary (95 ± 1% vs 91 ± 1%, P < 0.001) and secondary patency (98 ± 1% vs 94 ± 1%, P < 0.001), and higher freedom from TAI (87 ± 2% vs 84 ± 2%, P = 0.002) compared with TAs incorporated by DBs, with no differences in other TA events. DBs targeted by balloon-expandable stent-grafts had significantly lower freedom from TAI (78 ± 4% vs 88 ± 1%, P = 0.006), TA endoleak (87 ± 3% vs 97 ± 1%, P < 0.001), and TA reintervention (83 ± 4% vs 95 ± 1%, P < 0.001) compared with those targeted by self-expandable stent-grafts. CONCLUSIONS Incorporation of renal and mesenteric TA during FB-EVAR is safe and durable with high 5-year patency rates and low freedom from TAI. DBs have lower patency rates and lower freedom from TAI than fenestrations, with better performance for self-expandable stent grafts as compared with balloon-expandable stent grafts.
Collapse
|
17
|
Superior mesenteric artery aneurysm endovascular repair. J Vasc Surg Cases Innov Tech 2023; 9:101227. [PMID: 37799846 PMCID: PMC10547738 DOI: 10.1016/j.jvscit.2023.101227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 05/08/2023] [Indexed: 10/07/2023] Open
Abstract
Superior mesenteric artery aneurysms are rare and associated with high mortality rates in cases of rupture. Current Society for Vascular Surgery guidelines recommend treatment of all superior mesenteric artery aneurysms regardless of size. A 53-year-old woman who was admitted for abdominal pain was found with a 14-cm, ruptured superior mesenteric artery branch aneurysm. Endovascular approach was performed with microvascular plug embolization of a feeding branch and aneurysm sac exclusion with a stent graft. Four months later, the patient demonstrated a 21% regression of the aneurysm and stent patency. Thus, timely diagnosis and treatment of superior mesenteric artery aneurysms with endovascular techniques can reduce potential complications.
Collapse
|
18
|
Effect of bridging stent graft selection for directional branches on target artery outcomes of fenestrated-branched endovascular aortic repair in the United States Aortic Research Consortium. J Vasc Surg 2023; 78:10-28.e3. [PMID: 36948277 DOI: 10.1016/j.jvs.2023.03.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 03/05/2023] [Accepted: 03/07/2023] [Indexed: 03/24/2023]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effect of directional branches (DBs) bridging stent choice on target artery (TA) outcomes during fenestrated-branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms. METHODS Patients enrolled in nine prospective physician-sponsored investigational device exemption studies in the United States between 2005 and 2020 were analyzed. All patients who had at least one TA incorporated by DB using either self-expandable (SESGs), balloon-expandable (BESGs), or hybrid stent graft combinations (HSGs). Endpoints were TA patency and freedom from TA endoleak, instability, and reintervention. RESULTS There were 800 patients with 2426 renal-mesenteric arteries incorporated by DBs. DB stent selection was SESGs in 1205 TAs (50%), BESGs in 1095 TAs (45%), and HSGs in 126 TAs (5%). SESGs were predominantly used in the first three quartiles of the study period, whereas BESGs comprised 75% of all stents between 2017 and 2020. The median follow-up was 15 months (interquartile range, 6-35 months). At 5 years, BESGs had significantly lower freedom from TA instability (78% ± 4% vs 88% ± 1% vs 96% ± 2%; log-rank P =.010), freedom from TA endoleaks (87% ± 3% vs 97% ± 1% vs 99% ± 1%; log-rank P < .001), and freedom from TA reintervention (83% ± 4% vs 95% ± 1% vs 99% ± 2%; log-rank P <.001) compared with SESGs or HSGs, respectively. For renal arteries, there was no difference in freedom from TA instability for BESGs, SESGs, or HSGs. However, freedom from TA endoleaks and reintervention were lower for renal arteries targeted by BESGs compared with DBs targeted by SESGs and HSGs (83% ± 6% vs 98% ± 1% vs 100%; log-rank P < .001; and 70% ± 10% vs 92% ± 1% vs 96% ± 4%; log-rank P = .022). For mesenteric arteries, DBs targeted by BESGs had lower freedom from TA instability, endoleak, and reintervention than SESGs or HSGs. In stent-specific analysis, iCAST BESGs had the lowest freedom from TA instability either for renal or mesenteric arteries, primarily due to higher rates of TA endoleaks. There was no difference in patency in any scenario. Independent predictors of TA instability were age (+1-year: hazard ratio [HR], 0.97; 95% confidence interval [CI], 0.94-0.99), stent diameter (+1 mm: HR, 0.67; 95% CI, 0.57-0.80), and BESG (HR, 1.8; 95% CI, 1.1-2.9). CONCLUSIONS DBs incorporated using BESGs had lower freedom from TA instability, TA endoleak, and TA reintervention compared with SESGs and HSGs. The patency of DBs was not affected by the type of stent construction. The observed performance disadvantage associated with BESGs appears to have largely been driven by iCAST usage.
Collapse
|
19
|
Aneurysm extent-based mortality differences in complex endovascular repair of thoracoabdominal aneurysms in the Vascular Quality Initiative and the United States Aortic Research Consortium. J Vasc Surg 2023; 78:1-9.e3. [PMID: 36921644 DOI: 10.1016/j.jvs.2023.02.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 02/10/2023] [Accepted: 02/15/2023] [Indexed: 03/16/2023]
Abstract
BACKGROUND Endovascular management of thoracoabdominal aneurysms (TAAA) is becoming more common. Technological advances including custom devices under the Physician-Sponsored Investigational Device Exemption (PS-IDE), physician-modified endografts (PMEG), and parallel stenting techniques have expanded the extent of disease that is amenable to endovascular treatment. Patients within the PS-IDE studies are a highly selected group of patients, whereas patients treated with PMEG as captured within the Society for Vascular Surgery Vascular Quality Initiative (SVS VQI) represent a real-world experience. Research within both the SVS VQI on PMEG and the US Aortic Research Consortium (US-ARC) has demonstrated a relationship between extent of aneurysmal disease and mortality after complex endovascular TAAA repair, but no direct comparison of these cohorts has been conducted. In this study, we sought to compare outcomes of custom PS-IDE devices with off-label uses of commercially available devices for the endovascular management of TAAAs. METHODS A retrospective review of patients presenting for elective endovascular TAAA repair for asymptomatic disease between 2011 and 2019 was conducted within both the SVS VQI registry and the US-ARC. Patients within the SVS VQI registry were treated with either PMEG or with parallel stenting techniques. Patients within the US-ARC were treated with PS-IDE custom devices. The extent of aneurysm disease was defined by the deployment zones documented for the devices entered in the registry using Crawford extents I to V. Primary outcomes were 30-day and 1-year mortality rates. RESULTS A total of 3212 patients were included in the study: 1571 PMEG/parallel stenting within the VQI registry and 1641 with PS-IDE within the US-ARC database. The majority of patients presented with extent IV aneurysms (n = 1827 [57%]), with extent IV aneurysms being slightly more prevalent within the US-ARC cohort. Maximal aneurysm diameter within each extent did not vary between the US-ARC and VQI cohorts. Across all patients, the 30-day mortality was 4.4% and the 1-year mortality was 12.2%. Unadjusted mortality at 30-days was 6.7% within the VQI, and 2.2% in the US-ARC (P < .001). The unadjusted 1-year mortality was 14.3% within the VQI and 10.2% within the US-ARC (P < .001). When adjusted for aneurysm extent, similar differences in 30-day and 1-year survivals were identified. CONCLUSIONS Patients treated in PS-IDE studies had better 30-day and 1-year survival rates compared with those treated with a similar extent of disease using off-label approaches in a real-world registry. These differences are complex and likely associated with a number of factors, including arterial anatomy, patient comorbidities, device construct, and volume outcomes, as well as complex and unmeasurable surgeon- and patient-specific factors.
Collapse
|
20
|
Fiber Optic RealShape imaging using upper extremity and transfemoral access for fenestrated-branched endovascular aortic aneurysm repair. J Vasc Surg Cases Innov Tech 2023; 9:101191. [PMID: 37334157 PMCID: PMC10275972 DOI: 10.1016/j.jvscit.2023.101191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 03/30/2023] [Indexed: 06/20/2023] Open
Abstract
We report our initial experience using Fiber Optic RealShape (FORS), an innovative real-time three-dimensional visualization technology that uses light instead of radiation, to achieve upper extremity (UE) access during fenestrated/branched endovascular aortic aneurysm repair (FBEVAR). An 89-year-old male patient with a type III thoracoabdominal aortic aneurysm, unfit for open aortic repair, underwent FBEVAR. Dual fluoroscopy, intravascular ultrasound, and three-dimensional fusion overlay were used, in addition to FORS. All target artery catheterizations were successfully accomplished using FORS, from UE access, without radiation. Our experience demonstrates that FBEVAR with FORS using UE access can be used for target artery catheterization without radiation.
Collapse
|
21
|
Predictors and Outcomes of Spinal Cord Injury following Complex Branched/Fenestrated Endovascular Aortic Repair in the US Aortic Research Consortium. J Vasc Surg 2023; 77:1578-1587. [PMID: 37059239 DOI: 10.1016/j.jvs.2023.01.205] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/22/2023] [Accepted: 01/23/2023] [Indexed: 04/16/2023]
Abstract
OBJECTIVE Spinal cord ischemia (SCI) is a well-known complication of thoracoabdominal aortic aneurysm (TAAA) repair and is associated with profound morbidity and mortality. The purpose of this study was to describe predictors for the development of SCI, as well as outcomes for patients who develop SCI, after branched/fenestrated endovascular aortic repair (FB-EVAR) in a large cohort of centers with adjudicated physician-sponsored investigational device exemption studies. METHODS We utilized a pooled dataset from 9 United States Aortic Research Consortium (US ARC) centers involved in investigational device exemption (IDE) trials for treatment of suprarenal and thoracoabdominal aortic aneurysms. SCI was defined as new transient weakness (paraparesis) or permanent paraplegia after repair without other potential neurologic etiologies. Multivariable analysis was performed to identify predictors of SCI, and life-table analysis and Kaplan-Meier methodology were used to evaluate survival differences. RESULTS A total of 1,681 patients underwent FB-EVAR over the period 2005-2020. The overall rate of SCI was 7.1% (3% transient and 4.1% permanent). Predictors of SCI on multivariable analysis were Crawford Extent I, II, and III distribution of aortic disease (OR 4.79 95% CI 4.77- 4.81, P<.001), age ≥70 (OR 1.64, 95% CI, 1.63-1.64, P=.029), packed red blood cell transfusion (OR 2.00, 95% CI, 1.99-2.00, P=.001), and history of PVD (OR 1.65, 95% CI, 1.64-1.65, P=.034). Median survival was significantly worse for patients with any degree of SCI compared to those without SCI (any SCI - 40.4 vs no SCI - 60.3 months, Log Rank <.001), and also worse in those with a permanent deficit (24.1 months) vs. those with a transient deficit (62.4 months) (Log Rank <0.001). One year survival for patients who developed no SCI was 90.8%, compared to 73.9% in patients who developed any SCI. When stratified by degree of deficit, survival was 84.8% at one year for those who developed paraparesis, and 66.2% for those who developed permanent deficits. CONCLUSIONS The overall rates of any SCI at 7.1% and permanent deficit at 4.1% observed in this study compare favorably to those reported in contemporary literature. Our findings confirm that increased length of aortic disease is associated with SCI and those with Crawford Extent I-III TAAAs are at highest risk. The long-term impact on patient mortality underscores the importance of preventive measures and rapid implementation of rescue protocols if and when deficits develop.
Collapse
|
22
|
Early Results and Feasibility of Total Endovascular Aortic Arch Repair Using 3-Vessel Company-Manufactured and Physician-Modified Stent-Grafts. J Endovasc Ther 2023:15266028231163069. [PMID: 36978289 DOI: 10.1177/15266028231163069] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
Abstract
OBJECTIVE Total endovascular repair of aortic arch aneurysms is feasible in select patients. This study aims to evaluate the feasibility and early outcomes of total endovascular arch repair using 3-vessel company-manufactured devices (CMDs) and physician-modified endo grafts (PMEGs). METHODS Patients unfit for open repair who underwent 3-vessel total arch repair at a single institution from 2018 to 2021 were reviewed. Patients received either 3-vessel inner-branch CMDs or PMEGs. Three-vessel designs were used to incorporate the innominate, left common carotid, and left subclavian arteries. The antegrade inner branches in both devices were accessed via right brachial or carotid approach. The left carotid was accessed via carotid cutdown or femoral approach. The left subclavian artery was accessed via transfemoral approach. The study endpoints included procedural technical success, patient survival, neurologic events, cardiac complications, reinterventions, and target artery patency. RESULTS Nine patients underwent treatment. Four patients were treated with PMEGs, and 5 with CMDs. Procedural technical success was 100%. There were no in-hospital deaths. There were no strokes, transient ischemic attacks, myocardial infarction, or spinal ischemia in the perioperative period. Major adverse events occurred in 3 patients (33%). Two (22%) vascular access complications and one (11%) acute kidney injury occurred. One (11%) patient required early reintervention for an access complication. The median follow-up period was 358 days (CMD, 392 days; PMEG, 198 days). There was a late reintervention and conversion to open repair at 142 days of follow-up in a patient with a PMEG that developed an aortic infection, leading to death on postoperative day 239. The mean length of stay was 7±4 days. Computed tomography imaging obtained during the immediate postoperative period revealed endoleak in 6 (66%) patients, out of which 5 resolved spontaneously and 1 required reintervention via left subclavian artery stenting. Target artery patency was 100% at the end of the follow-up period. CONCLUSIONS Three-vessel total endovascular aortic arch repair using a CMD or PMEG is feasible with optimal early outcomes. Physician-modified stent-grafts are a feasible option for patients who do not meet anatomic criteria for CMDs. CLINICAL IMPACT Management of aortic arch disease remains a significant challenge in vascular surgery. This study showcases the feasibility and safety of using a total endovascular approach to repair the aortic arch, which could potentially reduce morbidity and mortality associated with traditional surgical approaches. The results suggest that this minimally invasive technique could be an alternative treatment option for high-risk patients and could significantly improve outcomes for those requiring aortic arch repair. Overall, this study represents a promising development in the field of endovascular surgery and highlights the potential to improve patient outcomes.
Collapse
|
23
|
Outcomes of carotid stenting in patients with fibromuscular dysplasia. J Vasc Surg 2023; 77:829-835. [PMID: 36400362 DOI: 10.1016/j.jvs.2022.10.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 10/25/2022] [Accepted: 10/26/2022] [Indexed: 11/17/2022]
Abstract
OBJECTIVE Fibromuscular dysplasia (FMD) is a noninflammatory arterial disease that affects the extracranial carotid arteries in young patients. The ideal treatment of FMD has continued to be debated, and the role of carotid artery stenting (CAS) is controversial. The aim of the present study was to assess the feasibility and outcomes of CAS for patients with FMD. METHODS A retrospective analysis of patients who had undergone CAS was performed using the Vascular Quality Initiative database from December 2012 to May 2021. Patients who had undergone CAS for atherosclerosis and FMD were included and matched 1:1 by age, gender, and clinical presentation. The demographics, clinical parameters, and procedural data were analyzed. The end points included postoperative stroke and transient ischemic attack (TIA), and adverse events (perioperative and 1-year mortality, neurologic changes, access site complications, hematoma or bleeding, infection, congestive heart failure, arrhythmia, myocardial infarction, reperfusion symptoms), and hospital length of stay. RESULTS After matching, 55 patients had undergone CAS for FMD (mean age, 58.7 ± 14 years; 62% women; 69% White; mean body mass index, 28 ± 6 kg/m2). Most of these procedures (69%) were elective. The FMD group had had a lower rate of hypertension (55% vs 82%; P = .002), smoking (35% vs 80%; P < .001), diabetes (13% vs 45%; P < .001), and coronary artery disease (9% vs 45%; P < .001) compared with the non-FMD group. In the FMD group, prior TIA and stroke was identified in 39 (71%) and 31 (57%) patients, respectively. The mean interval from a prior stroke or TIA to the index surgery was 160 days. Additionally, 23 patients (42%) had had anatomically high lesions above the level of the second cervical vertebra. In the FMD group, the transfemoral approach was used for 43 patients (78%), with distal embolic protection used for 40 patients (93%). Flow reversal was used for nine patients (23%). Most cases were performed with local anesthesia (58%). Three patients (6%) in the FMD group had had access site complications that were managed nonoperatively. No differences were found between the FMD and non-FMD groups in perioperative stroke, TIA, or 30-day mortality. The length of stay was similar between the two groups, and the 1-year survival was 100% for both groups. All the patients in the FMD group were discharged without neurologic complications, and 50 patients (91%) were receiving dual antiplatelet therapy. The median follow-up was 328 days (interquartile range, 1-732 days) with no mortality or reinterventions during follow-up. CONCLUSIONS CAS for FMD is a feasible and safe procedure with favorable technical success, a low incidence of neurologic complications, and good clinical outcomes at 1 year of follow-up.
Collapse
|
24
|
Outcomes of carotid stenting in patients with fibromuscular dysplasia. Eur J Vasc Endovasc Surg 2023. [DOI: 10.1016/j.ejvs.2023.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
|
25
|
Comparison of upper extremity and transfemoral access for fenestrated-branched endovascular aortic repair. J Vasc Surg 2023; 77:704-711. [PMID: 36257344 DOI: 10.1016/j.jvs.2022.10.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 10/07/2022] [Accepted: 10/09/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The use of upper extremity (UE) access is an accepted and often implemented approach for fenestrated/branched endovascular aortic aneurysm repair (F-BEVAR). The advent of steerable sheaths has enabled the performance of F-BEVAR using a total transfemoral (TF) approach without UE access, potentially decreasing the risks of cerebral embolic events. The purpose of the present study was to assess the outcomes of F-BEVAR using UE vs TF access. METHODS Prospectively collected data from nine physician-sponsored investigational device exemption studies at U.S. centers were analyzed using a standardized database. All patients were treated for complex abdominal aortic aneurysms (CAAAs) and thoracoabdominal aortic aneurysms (TAAAs) using industry-manufactured fenestrated and branched stent grafts between 2005 and 2020. The outcomes were compared between patients who had undergone UE vs total TF access. The primary composite outcome was stroke or transient ischemia attack (TIA) and 30-day or in-patient mortality during the perioperative period. The secondary outcomes included technical success, local access-related complications, and perioperative mortality. RESULTS Among 1681 patients (71% men; mean age, 73.43 ± 7.8 years) who had undergone F-BEVAR, 502 had had CAAAs (30%), 535 had had extent IV TAAAs (32%), and 644 had had extent I to III TAAAs (38%). UE access was used for 1103 patients (67%). The right side was used for 395 patients (24%) and the left side for 705 patients (42%). UE access was preferentially used for TAAAs (74% vs 47%; P < .001). In contrast, TF access was used more frequently for CAAAs (53% vs 26%; P < .01). A total of 38 perioperative cerebrovascular events (2.5%), including 32 strokes (1.9%) and 6 TIAs (0.4%), had occurred. Perioperative cerebrovascular events had occurred more frequently with UE access than with TF access (2.8% vs 1.2%; P = .036). An individual component analysis of the primary composite outcome revealed a trend for more frequent strokes (2.3% vs 1.2%; P = .13) and TIAs (0.54% vs 0%; P = .10) in the UE access group. On multivariable analysis, total TF access was associated with a 60% reduction in the frequency of perioperative cerebrovascular events (odds ratio, 0.39; P = .029). No significant differences were observed between UE and TF access in the technical success rate (96.5% vs 96.8%; P = .72), perioperative mortality (2.9% vs 2.6%; P = .72), or local access-related complications (6.5% vs 5.5%; P = .43). CONCLUSIONS In the present large, multicenter, retrospective analysis of prospectively collected data, a total TF approach for F-BEVAR was associated with a lower rate of perioperative cerebrovascular events compared with UE access. Although the cerebrovascular event rate was low with UE access, the TF approach offered a lower risk of stroke and TIA. UE access will continue to play a role for appropriately selected patients requiring more complex repairs with anatomy not amenable to the TF approach.
Collapse
|
26
|
Endovascular Reconstruction Aortic Bifurcation for Aortic Pseudoaneurysm in a Pediatric Trauma Patient. J Vasc Surg Cases Innov Tech 2023; 9:101140. [PMID: 37125341 PMCID: PMC10140168 DOI: 10.1016/j.jvscit.2023.101140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 02/10/2023] [Indexed: 03/07/2023] Open
Abstract
Endovascular treatment options for vascular injury in pediatric patients are quite limited owing to concerns regarding long-term durability and the lack of devices suitable for the pediatric anatomy. However, in rare circumstances, open surgical therapy will not be an option, and patients will require unconventional endovascular solutions for lifesaving or limb-saving therapies. In the present report, we describe an endovascular treatment of a pediatric patient for whom initial surgical management of a blunt abdominal aortic injury had failed, with subsequent development of an aortic pseudoaneurysm. A 10-year-old girl had presented after a high-speed motor vehicle accident with a seatbelt sign. Multiple abdominal injuries were identified, including blunt aortic injury, significant devitalization of the small bowel, colonic perforation with fecal contamination, multiple lumbar spine fractures, and pulmonary contusions. The patient developed bilateral lower extremity ischemia from the aortic injury and had initially undergone open repair. One month later, the patient had developed a pseudoaneurysm of the aorta near the aortic bifurcation. Because of the hostile abdomen and ensuing short gut syndrome, the pseudoaneurysm was managed using endovascular techniques. The limb of an Excluder internal iliac branch endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ) was used as the endograft. The aortic bifurcation was raised and reconstructed using four Viabahn self-expanding stents (W.L. Gore & Associates). The completion angiogram showed complete resolution of the pseudoaneurysm. The follow-up computed tomography angiogram showed widely patent stent grafts with complete resolution of the pseudoaneurysm. Endovascular management of traumatic vascular injuries in pediatric patients is feasible. The likelihood of reintervention in the future is high with patient growth. However, it is a viable option in lifesaving or limb-saving situations in which open repair is high risk.
Collapse
|
27
|
Operator Lower Leg Radiation Dose during Fluoroscopically Guided Interventions is Effectively Reduced by Wearing Lead-Equivalent Leg Wraps. Ann Vasc Surg 2023; 89:161-165. [PMID: 36162628 DOI: 10.1016/j.avsg.2022.09.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 08/29/2022] [Accepted: 09/03/2022] [Indexed: 01/25/2023]
Abstract
BACKGROUND The intensity of radiation scatter that emanates from the X-ray beam during fluoroscopically guided interventions is greater below the fluoroscopy table than above. Yet interventionalists' lower legs are typically unshielded and table skirts are often positioned incorrectly. We sought to characterize the efficacy of the leg protector wraps (Leg Wraps, Burlington Medical Inc.) in reducing the radiation dose to the operator's lower leg during fenestrated and branched endovascular aneurysm repair (F-BEVAR). METHODS A prospective cohort study was performed evaluating the lower leg radiation dose reduction of one vascular surgeon during F/BEVAR using antimony/bismuth Enviro-Lite leg wraps (0.35 mm lead equivalency, 99.7% attenuation at 50 kVp; Burlington Medical, Hampton Roads, Virginia). Optically Stimulated Luminescence nanoDot detectors (microSTARii System, LANDAUER, Inc., Glenwood, Illinois) were placed over and under the left leg wrap at the anterior tibial tuberosity position to compare operator leg dose with and without this additional protection. The table-mounted lead skirt was used consistently in all cases. The nanoDot detectors were cross-calibrated with a survey meter (RaySafe X2 survey sensor, Fluke Biomedical, Cleveland, Ohio) by measuring scattered radiation at a position equivalent to an operator's mid-tibia while performing digital acquisitions of a 25-cm thick, 30 cm × 30 cm acrylic phantom with a Philips FD20 fluoroscope (Philips Healthcare, Best, The Netherlands) with the table skirt removed. The measured radiation doses were converted to a Hp (0.07) skin dose, assuming an RQR6 beam spectrum (IEC-61267). Paired Wilcoxon test was performed to identify significant attenuation of radiation exposure. RESULTS Leg dose measurements from 40 F-BEVARs were analyzed. The patients had a median (interquartile range) body mass index of 27 (24-32) kg/m2. Median procedure reference air kerma was 1,100 (728-1,601) mGy, kerma-area product was 127 (73-184) Gycm2, and fluoroscopy time was 69 (54-86) min. The median skin dose Hp (0.07) over the leg wraps (n = 40) was 54.2 (24-100) μSv and under the leg wraps (n = 40) was 2.7 μSv (1.0-5.8). The leg wraps attenuated the radiation dose by 95% (89-98%) (P < 0.001). The unprotected, Hp (0.07) per kerma-area product was determined to be 0.38 (0.30-0.55) μSv/Gycm2. CONCLUSIONS The 0.35-mm lead-equivalent leg wraps significantly decreased scattered radiation to the lower leg during F-BEVAR. Protective leg wraps should be recommended to operators performing complex fluoroscopically guided procedures.
Collapse
|
28
|
Chronic kidney disease impacts outcomes after abdominal aortic aneurysm repair. J Vasc Surg 2023; 77:415-423.e1. [PMID: 36100032 DOI: 10.1016/j.jvs.2022.09.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 08/08/2022] [Accepted: 09/02/2022] [Indexed: 01/25/2023]
Abstract
OBJECTIVE Chronic kidney disease (CKD) and end-stage renal disease are traditionally associated with worse outcomes after endovascular and open repair of abdominal aortic aneurysm (AAA). This study stratifies outcomes of AAA repair by approach, CKD severity, and dialysis dependence. METHODS All patients undergoing elective infrarenal open aneurysm repair (OAR) and endovascular aortic repair (EVAR) with preoperative renal function data captured by the Vascular Quality Initiative between January 2003 and September 2020 were analyzed. Patients were stratified by CKD class as follows: CKD stages 1 and 2, CKD stage 3a, CKD stage 3b, CKD stages 4 and 5, and dialysis. Primary outcomes were perioperative and 1-year mortality. Predictors of survival were identified by Cox multivariate regression models. RESULTS In total, 53,867 elective AAA repairs were identified: 5396 (10%) OARs and 48,471 (90%) EVARs. Most patients were White (90%) and male (81%), with a mean age of 73 ± 9 years. Patients who underwent EVAR were older and had more comorbidities. The use of elective EVAR for AAA increased from 52% in 2003 to 91% in 2020 (P < .001). The OAR cohort had more perioperative complications and short-term mortality. The CKD 1 and 2 group had the highest 1-year survival compared with the other groups after both OAR and EVAR. On Cox regression analysis, after EVAR, compared with CKD 1 and 2, worsening CKD stage (CKD 3a: hazard ratio [HR], 1.25; 95% confidence interval [CI], 0.93-1.68; P = .13; CKD 3b: HR, 1.74; 95% CI, 1.23-2.45; P < .050; CKD 4-5: HR, 3.23; 95% CI, 2.13-4.88; P < .001), and dialysis (HR, 4.48; 95% CI, 1.90-10.6; P < .001) were independently associated with worse 1-year survival rates. After OAR, compared with CKD 1 and 2, worsening CKD stage (CKD 3a: HR, 1.08; 95% CI, 0.96-1.20; P = .20; CKD 3b: HR, 1.60; 95% CI, 1.41-1.81; P < .001; CKD 4-5: HR, 2.85; 95% CI, 2.39-3.41; P < .001), and dialysis (HR, 3.79; 95% CI, 3.01-4.76; P < .001) were independently associated with worse 1-year survival rates. CONCLUSIONS Regardless of the treatment approach, CKD severity is an important predictor of perioperative and 1-year mortality rates after infrarenal AAA repair and may reflect the natural history of CKD. Open repair is associated with high perioperative mortality risk in patients with CKD stages 4 and 5, as well as end-stage renal disease. Individualization of patient decision-making is especially important in patients with a glomerular filtration rate of less than 45 and perhaps consideration should be given to raising the threshold for elective AAA repair in these patients. Further studies focusing on appropriate size threshold for repair in these patients may be warranted.
Collapse
|
29
|
Selection criterion for endovascular aortic repair in those with chronic kidney disease. J Vasc Surg 2023; 77:1625-1635.e3. [PMID: 36731756 DOI: 10.1016/j.jvs.2023.01.185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 01/11/2023] [Accepted: 01/14/2023] [Indexed: 02/01/2023]
Abstract
OBJECTIVE Endovascular aortic repair (EVAR) is the preferred method of repair for abdominal aortic aneurysms (AAAs). However, patients with advanced chronic kidney disease (CKD) are a high-risk group, and it is unknown which patients with CKD benefit from EVAR vs continued surveillance. The purpose of this study was to identify which patients with advanced CKD may benefit from EVAR. METHODS The Vascular Quality Initiative Database was utilized to identify elective EVARs for AAAs. Patients were excluded if they underwent urgent or emergent repairs. CKD stages were categorized based on preoperative estimated glomular filtration rate (eGFR) and dialysis status. Predicted 1-year mortality of untreated AAAs was calculated by modifying a validated comorbidity score that predicts 1-year mortality (Gagne Index) without repair. The primary outcome was actual 1-year mortality, which was compared with the predicted 1-year mortality without repair. RESULTS A total of 34,926 patient met study criteria. There were differences in Gagne Indices among the varying classes of CKD. Patients with CKD 4 and CKD 5 had the highest 1-year mortality rates, followed by CKD 3b, which was significantly higher than those with CKD 1 and CKD 2. Patients with CKD 4 had no differences between actual 1-year mortality with EVAR and predicted 1-year survival without EVAR across all AAA sizes. Those with CKD 5 had worse actual 1-year survival with EVAR than predicted 1-year survival without EVAR for AAAs <5.5 cm. Patients with CKD 5 only experienced an actual mortality benefit with EVAR compared with predicted 1-year mortality without EVAR for AAAs ≥7.0 cm. CONCLUSION The current data suggest that patients with CKD 3b, 4, and 5 represent a high-risk group who may not benefit from elective EVAR utilizing traditional size criteria. Patients with CKD 4 and 5 with AAAs <5.5 cm do not benefit from elective EVAR. In patients with CKD 5, elective EVAR may need to be reserved for AAAs ≥7.0 cm unless there are other concerning anatomic characteristics.
Collapse
|
30
|
Abstract
BACKGROUND Hybrid debranching repair of pararenal and thoracoabdominal aortic aneurysms was initially designed as a better alternative to standard open repair, addressing the limitations of endovascular repair involving the visceral aorta. We reviewed the collective outcomes of hybrid debranching repairs using extra-anatomic, open surgical debranching of the renal-mesenteric arteries, followed by endovascular aortic stenting. METHODS Data from patients who underwent hybrid repair in 14 North American institutions during 10 years were retrospectively reviewed. Society of Vascular Surgery scores were used to assess comorbidity risk. Early and late outcomes, including mortality, morbidity, reintervention, and patency were analyzed. RESULTS A total of 208 patients (118 male; mean age, 71±8 years old) were treated by hybrid repair with extraanatomic reconstruction of 657 renal and mesenteric arteries (mean 3.2 vessels/patient). Mean aneurysm diameter was 6.6±1.3 cm. Thoracoabdominal aortic aneurysms were identified in 163 (78%) patients and pararenal aneurysms in 45 (22%). A single-stage repair was performed in 92 (44%) patients. The iliac arteries were the most common source of inflow (n=132; 63%), and most (n=150; 72%) had 3 or more bypasses. There were 30 (14%) early deaths, ranging widely across sites (0%-21%). A Society of Vascular Surgery comorbidity score >15 was the primary predictor of early mortality (P<0.01), whereas mortality was 3% in a score ≤9. Early complications occurred in 140 (73%) patients and included respiratory complications in 45 patients (22%) and spinal cord ischemia in 22 (11%), of whom 10 (45%) fully recovered. At 5 years, survival was 61±5%, primary graft patency was 90±2%, and secondary patency was 93±2%. The most significant predictor of late mortality was renal insufficiency (P<0.0001). CONCLUSIONS Mortality after hybrid repair and visceral debranching is highly variable by center, but strongly affected by preoperative comorbidities and the centers' experience with the technique. With excellent graft patency at 5 years, the outcomes of hybrid repair done at centers of excellence and in carefully selected patients may be comparable (or better) than traditional open or even totally endovascular approaches. However, in patients already considered as high-risk for surgery, it may not offer better outcomes.
Collapse
|
31
|
The development and potential implications of the US Fenestrated and Branched Aortic Research Consortium. Semin Vasc Surg 2022; 35:380-384. [DOI: 10.1053/j.semvascsurg.2022.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 07/19/2022] [Accepted: 08/13/2022] [Indexed: 11/11/2022]
|
32
|
Outcomes and strategies for utilization of brachial access and preloaded systems during F/BEVAR. Semin Vasc Surg 2022; 35:287-296. [DOI: 10.1053/j.semvascsurg.2022.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 08/06/2022] [Accepted: 08/08/2022] [Indexed: 11/11/2022]
|
33
|
Outcomes of off-the-shelf multibranched stent grafts with intentional occlusion of directional branches using endovascular plugs during endovascular repair of complex aortic aneurysms. J Vasc Surg 2022; 75:1142-1150.e4. [PMID: 34748899 DOI: 10.1016/j.jvs.2021.09.050] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/24/2021] [Indexed: 01/10/2023]
Abstract
OBJECTIVE To evaluate the technique and outcomes of intentional occlusion of directional branches (DBs) using endovascular plugs during branched endovascular aortic repair using off-the-shelf Zenith t-Branch thoracoabdominal (TAAA) stent grafts. METHODS We reviewed the clinical data and outcomes of all consecutive patients treated by branched endovascular aortic repair using off-the-shelf Zenith t-Branch TAAA stent-graft (Cook Medical, Bloomington, Ind) in seven academic centers from 2013 to 2019. All patients had at least one DB intentionally occluded using extension of the branch with balloon or self-expandable covered stent, followed by placement of endovascular plugs. Intentional occlusion was indicated in patients with variations in the normal four-vessel renal-mesenteric anatomy, pre-existing dialysis, or in those who failed catheterization of a target vessel. End points were 30-day/in-hospital mortality, major adverse events, secondary interventions, target artery (TA) patency, TA instability, and patient survival. RESULTS There were 100 patients, 65 male and 35 female, with median age of 71 years (interquartile range [IQR], 66-75 years). Of these, 31 patients (31%) had urgent/emergent operations for symptomatic/contained ruptured aneurysms. The median aneurysm diameter was 72 mm (IQR, 61-85 mm). A total of 290 renal-mesenteric arteries were incorporated with a median of three (IQR, 3-3) vessels/patient. Indications for DB occlusion were less than four suitable renal-mesenteric targets in 84 patients or pre-existing dialysis and inability to catheterize a target vessel in eight patients each. There were 110 DBs occluded by vascular plugs, including 48 celiac axis, one superior mesenteric artery, and 61 renal DBs. Thirty-day/in-hospital mortality was 10%, including 9% for elective and 13% for urgent/emergent procedures. Major adverse events occurred in 44 patients (44%), including acute kidney injury in 19 patients (19%), estimated blood loss >1 L in 12 patients (12%), respiratory failure and new onset dialysis in six patients (6%) each, bowel ischemia in five patients (5%), and myocardial infarction and paraplegia in two patients (2%) each. The median follow-up was 5 months (range, 1-13 months). Eighteen patients (18%) required secondary interventions, none for problems related to the occluded DB. There were no endoleaks related to the occluded DB. At 2 years, primary and secondary patency and freedom from TA instability were 93% ± 3%, 97% ± 2%, and 91% ± 4%, respectively. Freedom from secondary interventions and patient survival were 75% ± 6% and 63% ± 7%, respectively. CONCLUSIONS Intentional occlusion of DBs using endovascular plugs allows versatile use of a four-vessel off-the-shelf multi-branched TAAA stent graft in patients with variations in the normal renal and mesenteric anatomy or when technical difficulties prevent successful target vessel stenting. There were no endoleaks or secondary interventions associated with the occluded DB.
Collapse
|
34
|
New imaging technology system reduces patient radiation dose during peripheral arterial endovascular interventions. J Vasc Surg 2022; 76:500-504. [PMID: 35367567 DOI: 10.1016/j.jvs.2022.03.865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Accepted: 03/23/2022] [Indexed: 11/24/2022]
Abstract
BACKGROUND Radiation exposure and imaging quality are among the main concerns in endovascular procedures. The Clear VD11 PURE platform technology system (Siemens Healthineers, Erlangen, Germany) has been reported to lower the radiation dose and improve image quality. In the present study, we evaluated whether the radiation dose during peripheral arterial endovascular procedures had decreased after implementation of this new imaging system. METHODS The patient characteristics (age, gender, body mass index [BMI]), procedure type (diagnostic, balloon angioplasty, atherectomy, stenting), body location (aortoiliac, superficial femoral artery, tibial artery), reference air kerma (RAK), kerma area product (KAP), and fluoroscopy time (FT) were recorded during peripheral artery interventions performed 1 year before (group A) and 1 year after (group B) the CLEAR system upgrade. The procedures were performed in an Artis zeego hybrid room (Siemens Healthineers) with the same providers. A general linear model was used to estimate the average difference between groups adjusted by procedure type and patient age, gender, and BMI. Additionally, to control for variations in case complexity, groups A and B were matched by age, gender, BMI, lesion location, and intervention type. Propensity score matching and a paired t test were used to compare the KAP, RAK, and FT stratified by single intervention procedures. RESULTS A total of 487 endovascular procedures were performed: 209 in group A and 278 in group B. A total of 111 single intervention procedures from each group were matched (1:1), with a mean age of 61 ± 8 years and a BMI of 26.5 ± 4 kg/m2. The median KAP, RAK, and FT for group A were 28.8 Gy · cm2 (interquartile range [IQR], 24-34 Gy · cm2), 146 mGy (IQR, 123-173 mGy), and 12 minutes (IQR, 10-14 minutes), respectively. The median KAP, RAK, and FT for group B were 18.3 Gy · cm2 (IQR, 16-22 Gy · cm2), 71.2 mGy (IQR, 60-85 mGy), and 10.4 minutes (IQR, 9-12 minutes), respectively. The KAP, RAK, and FT were significantly decreased in group B by 24% (P = .005), 41% (P < .001), and 22% (P = .002), respectively, compared with the values for group A. Stratified by single intervention procedures, the KAP and RAK had decreased significantly in group B (36% [P = .002] and 51% [P < .001], respectively) compared with group A. The FT decrease of 13% in group B was not statistically significant (P = .20). CONCLUSIONS Use of the Clear VD11 PURE platform system (Siemens Healthineers) reduced the patient radiation dose by 51% during endovascular peripheral interventions. The similar FTs for the matched single intervention procedures before and after the upgrade indicated consistent case complexity and surgeon practice. This platform appears to be an effective system for lowering the radiation dose.
Collapse
|
35
|
Perioperative neurologic outcomes of right versus left upper extremity access for fenestrated-branched endovascular aortic aneurysm repair. J Vasc Surg 2022; 75:794-802. [PMID: 34597786 PMCID: PMC9013472 DOI: 10.1016/j.jvs.2021.08.093] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Accepted: 08/23/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Upper extremity (UE) access is frequently used for fenestrated-branched endovascular aortic aneurysm repair (F-BEVAR), particularly for complex repairs. Traditionally, left-side UE access has been used to avoid crossing the arch and the origin of the supra-aortic vessels, which could potentially result in cerebral embolization and an increased risk of perioperative cerebrovascular events. More recently, right UE has been more frequently used as it is more convenient and ergonomic. The purpose of this study was to assess the outcomes and cerebrovascular events after F-BEVAR with the use of right- vs left-side UE access. METHODS During an 8-year period, 453 patients (71% male) underwent F-BEVAR at a single institution. UE access was used in more complex repairs. Left UE access was favored in the past, whereas right UE access is currently the preferred UE access side. Brachial artery cutdown was used in all patients for the placement of a 12F sheath. Outcomes were compared between patients undergoing right vs left UE access. End points included cerebrovascular events, perioperative mortality, technical success, and local access-related complications. RESULTS UE access was used in 361 (80%) patients. The right side was used in 232 (64%) and the left side in 129 (36%) patients for the treatment of 88 (25%) juxtarenal, 135 (38%) suprarenal, and 137 (38%) thoracoabdominal aortic aneurysms. Most procedures were elective (94%). Technical success was achieved in 354 patients (98%). In-patient or 30-day mortality was 3.3%. Five (1%) perioperative strokes occurred in patients undergoing right UE access, of which three were ischemic and two were hemorrhagic. No transient ischemic attacks occurred perioperatively. Two hemorrhagic strokes were associated with permissive hypertension to prevent spinal cord ischemia. No perioperative strokes occurred in patients undergoing left UE access (P = .16). Overall, perioperative strokes occurred with similar frequency in patients undergoing UE (5, 1%) and femoral access only (1, 1%) (P = .99). Arm access-related complications occurred in 15 (5%) patients, 11 (4.8%) on the right side and 4 (6%) on the left side (P = .74). CONCLUSIONS Right UE access can be used for F-BEVAR with low morbidity and minimal risk of perioperative ischemic stroke or transient ischemic attacks. In general, UE access is not associated with an increased risk of perioperative stroke compared with femoral access only. Tight blood pressure control is, however, critical to avoid intracranial bleeding related to uncontrolled hypertension.
Collapse
|
36
|
Understanding who Benefits from Endovascular Aortic Repair in those Deemed Unfit for Open Repair. J Vasc Surg 2022; 76:419-427.e3. [DOI: 10.1016/j.jvs.2022.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 02/05/2022] [Indexed: 11/16/2022]
|
37
|
Early Results and Feasibility of Total Endovascular Aortic Arch Repair Using Three-Vessel Company-manufactured and Physician-modified Stent Grafts. J Vasc Surg 2022. [DOI: 10.1016/j.jvs.2021.11.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
38
|
Accuracy and Utility of Intraoperative Contrast-Enhanced Ultrasound After Complex Endovascular Aortic Aneurysm Repair. J Vasc Surg 2022. [DOI: 10.1016/j.jvs.2021.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
39
|
Secondary interventions after fenestrated/branched aneurysm repairs are common and non-detrimental to long-term survival. J Vasc Surg 2021; 75:1530-1538.e4. [PMID: 34954272 DOI: 10.1016/j.jvs.2021.11.074] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 11/25/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Secondary interventions are common following endovascular repair of aortic aneurysms. However, the frequency and procedural details of secondary intervention following fenestrated and branched repairs (F/BEVAR) have been less well described, and the impact on long-term survival and aneurysm-related mortality is unknown. METHODS Consecutive patients enrolled as part of a multicenter research consortium in nine independent physician-sponsored investigational device exemption studies from 2005-2020 were evaluated. All secondary interventions performed after the initial procedure were classified as open or percutaneous and as major or minor, as per SVS reporting standards. Secondary interventions were further classified as high or low magnitude according to the physiologic impact of the intervention. Demographics, procedural details, and perioperative outcomes were compared for those who underwent secondary interventions and those who did not. Kaplan-Meier and Cox Proportional Hazard Ratio analysis were utilized to evaluate long-term survival. RESULTS Of 1681 patients who underwent F/BEVAR, 385 (23%) underwent secondary intervention at any point in follow-up. Freedom from reintervention was 82% at 1-year and 59% at 5-year follow up. Mean follow-up was 23 months. The majority of secondary interventions were percutaneous (84%), minor (70%), and low magnitude (81%). Renal stenting (30%) and access related procedures (24%) were the most frequent percutaneous and open procedures, respectively. High magnitude operations were performed in 19% of patients. Technical success was achieved for 94% of secondary interventions and mortality from secondary intervention was less than 1%. Secondary interventions as a whole were associated with improved long-term survival (Hazard Ratio: 0.6 95% Confidence Interval: 0.5-0.7). In subgroup analysis, major (HR: 0.6, 95% CI 0.4-0.8), minor (HR: 0.6, 95% CI: 0.5-0.8), low magnitude (HR 0.5, 95% CI: 0.4-0.7), and percutaneous (HR: 0.6, 95% CI: 0.5-0.7) secondary interventions were associated with improved survival; however high magnitude (HR: 1.0, 95% CI: 0.7-1.5) and open secondary interventions (HR: 1.0, 95% CI: 0.7-1.5) were not. Similarly, when aneurysm-related survival was specifically assessed, low magnitude secondary interventions were found to improve survival (HR: 0.3, 95% CI: 0.1-0.7), while high magnitude secondary interventions (HR: 2.8, 95% CI: 1.4-5.8) and open secondary interventions (HR: 2.7, 95% CI: 1.3-5.5) were associated with increased mortality. CONCLUSIONS Secondary interventions after F/BEVAR are frequent and are typically percutaneous, minor, and low magnitude procedures. While uncommon, high magnitude and open secondary interventions are associated with decreased long-term survival and increased aneurysm-related mortality. These data highlight the importance of close, life-long surveillance, and suggest that a significant rate of secondary intervention should be anticipated, but these do not negatively impact survival.
Collapse
|
40
|
Abstract
PURPOSE Treatment decisions for the elderly with abdominal aortic aneurysms (AAAs) are challenging. With advancing age, the risk of endovascular aneurysm repair (EVAR) increases while life expectancy decreases, which may nullify the benefit of EVAR. The purpose of this study was to quantify the impact of EVAR on 1-year mortality in patients of advanced age. MATERIALS AND METHODS The 2003-2020 Vascular Quality Initiative Database was utilized to identify patients who underwent EVAR for AAAs. Patients were included if they were 80 years of age or older. Exclusions included non-elective surgery or missing aortic diameter data. Predicted 1-year mortality of untreated AAAs was calculated based on a validated comorbidity score that predicts 1-year mortality (Gagne Index, excluding the component associated with AAAs) plus the 1-year aneurysm-related mortality without repair. The primary outcome for the study was 1-year mortality. RESULTS A total of 11 829 patients met study criteria. The median age was 84 years [81, 86] with 9014 (76.2%) being male. Maximal AAA diameters were apportioned as follows: 39.6% were <5.5 cm, 28.6% were 5.5-5.9 cm, 21.3% were 6.0-6.9 cm, and 10.6% were ≥7.0 cm. The predicted 1-year mortality rate without EVAR was 11.9%, which was significantly higher than the actual 1-year mortality rate with EVAR (8.2%; p<0.001). The overall rate of perioperative MACE was 4.4% (n = 516). Patients with an aneurysm diameter <5.5cm had worse actual 1-year mortality rates with EVAR compared to predicted 1-year mortality rates without EVAR. In contrast, those with larger aneurysms (≥5.5cm) had better actual 1-year mortality rates with EVAR. The benefit from EVAR for those with Gagne Indices 2-5 was largely restricted to those with AAAs ≥ 7.0cm; whereas those with Gagne Indices 0-1 experience a survival benefit for AAAs larger than 5.5 cm. CONCLUSION The current data suggest that EVAR decreases 1-year mortality rates for patients of advanced age compared to non-operative management in the elderly. However, the survival benefit is largely limited to those with Gagne Indices 0-1 with AAAs ≥ 5.5 cm and Gagne Indices 2-5 with AAAs ≥ 7.0 cm. Those of advanced age may benefit from EVAR, but realizing this benefit requires careful patient selection.
Collapse
|
41
|
Reinterventions After Branched/Fenestrated Aortic Aneurysm Repairs Are Common and Nondetrimental to Long-term Survival. J Vasc Surg 2021. [DOI: 10.1016/j.jvs.2021.06.451] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
42
|
VESS Paper SessionAortic Coverage Above the Celiac Artery and Risk Factors for Spinal Cord Ischemia After Fenestrated and Branched Endovascular Aneurysm Aortic Repair (F-BEVAR). J Vasc Surg 2021. [DOI: 10.1016/j.jvs.2021.06.055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
43
|
Benefits of Contrast-Enhanced Ultrasound During Endoleak Treatment. J Vasc Surg 2021. [DOI: 10.1016/j.jvs.2021.06.156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
44
|
Ultrasound-Guided Transgraft and Transcaval Embolization of Type II Endoleak. J Vasc Surg 2021. [DOI: 10.1016/j.jvs.2021.06.472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
45
|
Endovascular Aortic Repair in Those Unfit for Open Repair. J Vasc Surg 2021. [DOI: 10.1016/j.jvs.2021.06.313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
46
|
Current role of physician-modified endovascular grafts for fenestrated endovascular aortic aneurysm repair. J Vasc Surg 2021; 74:832. [PMID: 34425954 DOI: 10.1016/j.jvs.2021.01.043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 01/25/2021] [Indexed: 11/18/2022]
|
47
|
Effect of Abdominal Aortic Aneurysm Size on Mid-Term Mortality After Endovascular Repair. J Surg Res 2021; 267:443-451. [PMID: 34237629 DOI: 10.1016/j.jss.2021.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 02/17/2021] [Accepted: 06/01/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Previous studies have suggested that large preoperative AAA size may impact late survival after elective EVAR. It is unclear, however, whether this association applies to patients with smaller AAA between 5.0-5.5 cm, who constitute a substantial portion of patients undergoing elective EVAR. The purpose of this study was to delineate the effect of AAA size between 5.0 and 5.5 cm on mid-term mortality after EVAR by analyzing a large national cohort, the Vascular Quality Initiative (VQI) database. METHODS Using the Vascular Quality Initiative (VQI) national database, patients who underwent EVAR for intact AAA between 2003 and 2018 were identified and stratified based on maximal AAA diameter into 3 groups: Group 1 (4.0 cm ≤ AAA <5.0 cm); Group 2 (5.0 cm ≤ AAA < 5.5 cm); and Group 3 (AAA ≥ 5.5 cm). Cox proportional hazard model and propensity score matching method were used to estimate AAA size effect on all-cause mortality at 1, 3, and 5 years after EVAR while adjusting for potential confounders. RESULTS The study included 32,398 patients, of whom 81% were men with a mean age of 74. The most common group who underwent EVAR was Group 2 (5.0 cm ≤ AAA < 5.5 cm). Larger AAA size was associated with male sex (75% versus 79% versus 84%, for Groups 1, 2, and 3 respectively; P < 0.0001) and with coronary artery disease (27% versus 29% versus 31%, for Groups 1, 2, and 3 respectively, P< 0.0001); but was negatively associated with active smoking (33% versus 31% versus 30%, for Groups 1, 2, and 3, respectively, P< 0.001). While 10% of the largest and smallest AAA groups (Groups 3 and 1, respectively) were symptomatic, only 5% of patients in Group 2 were symptomatic (P < 0.01). Adjusted Cox proportional hazard modeling revealed that patients in Group 2 were at significantly lower risk of 5-year mortality when compared to patients in Group 3 (HR 0.66, 95% CI 0.61-0.72, P< 0.01), while similar in risk when compared to patients in Group 1 (HR 1.11, 95% CI 0.93-1.32, P= 0.26). CONCLUSION Our analysis found that over 40% of EVAR in the national VQI cohort were performed for AAA < 5.5 cm, with the greatest number of patients undergoing EVAR at AAA size 5.0-5.5cm. Patients with AAA size 5.0-5.5 cm had better 5-year survival outcomes than patients with AAA ≥ 5.5 cm, and similar survival to patients with small AAA between 4.0-5.0 cm.
Collapse
|
48
|
Selective Versus Routine Spinal Drain Use for Fenestrated/Branched Endovascular Aortic Repair (F-BEVAR). Ann Vasc Surg 2021; 76:168-173. [PMID: 34147637 DOI: 10.1016/j.avsg.2021.05.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/07/2021] [Accepted: 05/14/2021] [Indexed: 11/18/2022]
Abstract
BACKGROUND Spinal drains are used to ameliorate spinal cord ischemia (SCI), but their use may result in inherent morbidity and mortality. Although prophylactic spinal drain has proven of benefit in open repairs, that is not the case for endovascular repairs. The aim of this study was to assess the outcomes of spinal cord protection with and without the routine use of spinal drains during fenestrated-branched endovascular repair (F-BEVAR). METHODS A retrospective single center study was performed using a prospectively maintained dataset of all patients undergoing F-BEVAR over a 4-year period. The primary endpoint of the study was the frequency of SCI. Prophylactic spinal drain was placed pre-operatively in 33 patients (23%) with a median time for removal of 3 days (IQR, 2-3 days). Routine intraoperative neuromonitoring was used. Spinal cord protection relied primarily on maintaining a perioperative systolic blood pressure between 140 and 160 mm Hg or a mean arterial pressure >90 mm Hg, avoiding hypotension, preservation of as many collateral beds as possible, staged repairs and early lower extremity reperfusion based on neuromonitoring. RESULTS A total of 145 patients, 104 men (71%) and 41 women (28%) with a median age of 70 years (interquartile range [IQR], 53-62) underwent F-BEVAR. Branched custom-made devices (CMDs) (11%), fenestrated CMDs (70%) and off-the-shelf T-Branch device (17%) were used with a median number of branches/fenestrations of 4 (IQR, 3-4). SVS classification of implantation zones were determined as follows: 9 (6%) zone 2, 21 (20%) zone 3, 26 (18%) zone 4 and 89 (61%) zone 5. SCI was present in 8 patients (5.5%) and classified according to the SVS SCI grading system as follows: 1 grade 1, 5 grade 2 and 2 grade 3a. When evaluating implantation zone independently of coverage length and patency of collateral beds, a high implantation zone (1-4) was not associated with SCI (P = 0.9). Similarly, prophylactic spinal drain did not demonstrate association with the occurrence of SCI (3[9%] vs. 5[4%], with and without spinal drain, respectively) (P = 0.3). For patients with high implantation zones, staged repair was performed in 38 patients (26%) at a median time of 2 months (IQR, 2-6 months). Among these patients, the frequency of SCI was 13%. Staged repair was associated with an 80% reduction in the frequency of SCI (OR, 0.19 [95% CI, 0.04-0.084]) (P = 0.02). CONCLUSION F-BEVAR can be performed with a minimal risk of SCI without the need for routine prophylactic spinal drains. High implantation zones did not predict SCI after F-BEVAR; however, staged repair significantly decreased the risk of SCI after F-BEVAR.
Collapse
|
49
|
Impact of Dual Antiplatelet Therapy after Lower Extremity Revascularization for Chronic Limb Threatening Ischemia (CLTI). J Vasc Surg 2021; 74:1327-1334. [PMID: 34023428 DOI: 10.1016/j.jvs.2021.04.067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 04/23/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND The optimal antiplatelet regimen after lower extremity revascularization in patients with chronic limb threatening ischemia (CLTI) is unknown since current recommendations are based on extrapolation of data from trials in coronary artery disease and stroke. METHODS We identified all patients undergoing an elective lower extremity revascularization for CLTI in the Vascular Quality Initiative registry discharged on a mono antiplatelet agent (MAPT) or dual antiplatelet therapy (DAPT). RESULTS From 2003 to 2018, 50,890 patients underwent revascularization procedures for CLTI, and were discharged on MAPT or DAPT. Of these, 33,781 patients underwent endovascular therapy (EVT) and 17,109 patients underwent open surgery (OS) procedures. The rate of major amputation at 30 days in the target limb in the EVT group was 0.3% and 0.4% in the OS group (P=.22). On Kaplan Meier analyses, patients on MAPT at discharge had a higher risk 1-year major amputation compared to DAPT after EVT but not after OS procedures. Patients on MAPT had lower overall survival and amputation free survival (AFS) at 30 days and 1 year compared to DAPT after both EVT and OS. At 1 year, the MAPT group was at higher risk for target lesion re-intervention after EVT compared to the DAPT group (15.9% vs. 13%, P= .0012). There was no significant difference in thrombosis at 1 year between MAPT and DAPT groups either after EVT (3.9% vs. 3.7%; P = .3048) or OS (3.1% vs. 3.2%; P= .2893). On cox regression analysis, DAPT was associated with improved survival but not major amputation after both EVT and OS. CONCLUSIONS In CLTI patients, DAPT at the time of discharge has a positive impact on AFS and overall survival after both EVT and OS as well as target lesion re-intervention after EVT. DAPT was not associated with a positive impact on major amputation after either EVT or OS.
Collapse
|
50
|
Multicenter global early feasibility study to evaluate total endovascular arch repair using three-vessel inner branch stent-grafts for aneurysms and dissections. J Vasc Surg 2021; 74:1055-1065.e4. [PMID: 33865950 DOI: 10.1016/j.jvs.2021.03.029] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Accepted: 03/08/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE We evaluated the outcomes of total endovascular aortic arch repair using three-vessel inner branch stent-grafts for aneurysms and chronic dissections. METHODS We reviewed the clinical data and outcomes of consecutive patients treated by total endovascular aortic arch repair at eight academic centers using three-vessel inner branch stent-grafts (William Cook Europe, Bjaeverskov, Denmark) from 2016 to 2019. All patients received three-vessel designs with two antegrade and one retrograde inner branch, which was used to incorporate the innominate, left common carotid, and left subclavian arteries. The antegrade inner branches were accessed via a carotid or an upper extremity approach. A preloaded catheter was used for access to the retrograde left subclavian artery branch via a transfemoral approach. The endpoints were technical success, mortality, major adverse events, any stroke (minor or major) or transient ischemia attack, secondary interventions, target vessel patency, target vessel instability, aneurysm-related mortality, and patient survival. RESULTS A total of 39 patients (31 men [79%]; mean age, 70 ± 7 years) had undergone treatment of 14 degenerative (36%) and 25 chronic (64%) postdissection arch aneurysms. The clinical characteristics included American Society of Anesthesiologists class ≥III in 28 patients (95%) and previous median sternotomy for ascending aortic repair in 28 patients (72%). The technical success rate was 100%. Two patients had died in-hospital or within 30 days (5%), and two patients had experienced a stroke (one minor). The combined mortality and any stroke rate was 8% (n = 3). Major adverse events occurred in 10 patients (26%), including respiratory failure in 4 (10%) and estimated blood loss >1 L, myocardial infarction, and acute kidney injury in 2 patients each (5%). The median follow-up was 3.2 months (interquartile range, 1-14 months). Of the 39 patients, 12 (31%) required secondary interventions to treat vascular access complications in 5, endoleak in 6 (three type II, one type Ic, one type Ia/Ib, one type IIIa), and target vessel stenosis in 1 patient. At 1 year, the primary and secondary patency rates and freedom from target vessel instability were 95% ± 5%, 100%, and 91% ± 5%, respectively. Freedom from aortic-related mortality and patient survival was 94% ± 4% and 90% ± 6%, respectively. CONCLUSIONS The findings from the present multicenter global experience have demonstrated the technical feasibility and safety of total endovascular aortic arch repair for aneurysms and chronic dissections using three-vessel inner branch stent-grafts. The mortality and stroke rates compare favorably with those after open surgical repair in a higher risk group of patients. However, the rate of secondary interventions was high (31%), emphasizing need for greater experience and longer follow-up.
Collapse
|