1
|
Intraoperative Needle Tip Tracking with an Integrated Fibre-Optic Ultrasound Sensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:9035. [PMID: 36501738 PMCID: PMC9739176 DOI: 10.3390/s22239035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 06/17/2023]
Abstract
Ultrasound is an essential tool for guidance of many minimally-invasive surgical and interventional procedures, where accurate placement of the interventional device is critical to avoid adverse events. Needle insertion procedures for anaesthesia, fetal medicine and tumour biopsy are commonly ultrasound-guided, and misplacement of the needle may lead to complications such as nerve damage, organ injury or pregnancy loss. Clear visibility of the needle tip is therefore critical, but visibility is often precluded by tissue heterogeneities or specular reflections from the needle shaft. This paper presents the in vitro and ex vivo accuracy of a new, real-time, ultrasound needle tip tracking system for guidance of fetal interventions. A fibre-optic, Fabry-Pérot interferometer hydrophone is integrated into an intraoperative needle and used to localise the needle tip within a handheld ultrasound field. While previous, related work has been based on research ultrasound systems with bespoke transmission sequences, the new system-developed under the ISO 13485 Medical Devices quality standard-operates as an adjunct to a commercial ultrasound imaging system and therefore provides the image quality expected in the clinic, superimposing a cross-hair onto the ultrasound image at the needle tip position. Tracking accuracy was determined by translating the needle tip to 356 known positions in the ultrasound field of view in a tank of water, and by comparison to manual labelling of the the position of the needle in B-mode US images during an insertion into an ex vivo phantom. In water, the mean distance between tracked and true positions was 0.7 ± 0.4 mm with a mean repeatability of 0.3 ± 0.2 mm. In the tissue phantom, the mean distance between tracked and labelled positions was 1.1 ± 0.7 mm. Tracking performance was found to be independent of needle angle. The study demonstrates the performance and clinical compatibility of ultrasound needle tracking, an essential step towards a first-in-human study.
Collapse
|
2
|
Ultrasonic Needle Tracking with Dynamic Electronic Focusing. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:520-529. [PMID: 34974926 DOI: 10.1016/j.ultrasmedbio.2021.11.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/28/2021] [Accepted: 11/17/2021] [Indexed: 06/14/2023]
Abstract
Accurate identification of the needle tip is a key challenge with ultrasound-guided percutaneous interventions in regional anaesthesia, foetal surgery and cardiovascular medicine. In this study, we developed an ultrasonic needle tracking system in which the measured needle tip location was used to set the electronic focus of the external ultrasound imaging probe. In this system, needle tip tracking was enabled with a fibre-optic ultrasound sensor that was integrated into a needle stylet, and the A-lines recorded by the sensor were processed to generate tracking images of the needle tip. The needle tip position was estimated from the tracking images. The dependency of the tracking image on the electronic focal depth of the external ultrasound imaging probe was studied in a water bath and with needle insertions into a clinical training phantom. The variability in the estimated tracked position of the needle tip, with the needle tip at fixed depths in the imaging plane across a depth range from 0.5 to 7.5 cm, was studied. When the electronic focus was fixed, the variability of tracked position was found to increase with distance from that focus. The variability with the fixed focus was found to depend on the the relative distance between the needle tip and focal depth. It was found that with dynamic focusing, the maximum variability of tracked position was below 0.31 mm, as compared with 3.97 mm for a fixed focus.
Collapse
|
3
|
Precision-Microfabricated Fiber-Optic Probe for Intravascular Pressure and Temperature Sensing. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2021; 27:7100412. [PMID: 33716587 PMCID: PMC7951063 DOI: 10.1109/jstqe.2021.3054727] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 01/05/2021] [Accepted: 01/21/2021] [Indexed: 05/21/2023]
Abstract
Small form-factor sensors are widely used in minimally invasive intravascular diagnostic procedures. Manufacturing complexities associated with miniaturizing current fiber-optic probes, particularly for multi-parameter sensing, severely constrain their adoption outside of niche fields. It is especially challenging to rapidly prototype and iterate upon sensor designs to optimize performance for medical devices. In this work, a novel technique to construct a microscale extrinsic fiber-optic sensor with a confined air cavity and sub-micron geometric resolution is presented. The confined air cavity is enclosed between a 3 μm thick pressure-sensitive distal diaphragm and a proximal temperature-sensitive plano-convex microlens segment unresponsive to changes in external pressure. Simultaneous pressure and temperature measurements are possible through optical interrogation via phase-resolved low-coherence interferometry (LCI). Upon characterization in a simulated intravascular environment, we find these sensors capable of detecting pressure changes down to 0.11 mmHg (in the range of 760 to 1060 mmHg) and temperature changes of 0.036 °C (in the range 34 to 50 °C). By virtue of these sensitivity values suited to intravascular physiological monitoring, and the scope of design flexibility enabled by the precision-fabricated photoresist microstructure, it is envisaged that this technique will enable construction of a wide range of fiber-optic sensors for guiding minimally invasive medical procedures.
Collapse
|
4
|
Elastic scattering spectroscopy for early detection of breast cancer: partially supervised Bayesian image classification of scanned sentinel lymph nodes. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-9. [PMID: 30132305 PMCID: PMC8357191 DOI: 10.1117/1.jbo.23.8.085004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2018] [Accepted: 07/09/2018] [Indexed: 06/08/2023]
Abstract
Sentinel lymph node biopsy is a standard diagnosis procedure to determine whether breast cancer has spread to the lymph glands in the armpit (the axillary nodes). The metastatic status of the sentinel node (the first node in the axillary chain that drains the affected breast) is the determining factor in surgery between conservative lumpectomy and more radical mastectomy including axillary node excision. The traditional assessment of the node requires sample preparation and pathologist interpretation. An automated elastic scattering spectroscopy (ESS) scanning device was constructed to take measurements from the entire cut surface of the excised sentinel node and to produce ESS images for cancer diagnosis. Here, we report on a partially supervised image classification scheme employing a Bayesian multivariate, finite mixture model with a Markov random field (MRF) spatial prior. A reduced dimensional space was applied to represent the scanning data of the node by a statistical image, in which normal, metastatic, and nonnodal-tissue pixels are identified. Our results show that our model enables rapid imaging of lymph nodes. It can be used to recognize nonnodal areas automatically at the same time as diagnosing sentinel node metastases with sensitivity and specificity of 85% and 94%, respectively. ESS images can help surgeons by providing a reliable and rapid intraoperative determination of sentinel nodal metastases in breast cancer.
Collapse
|
5
|
Through-needle all-optical ultrasound imaging in vivo: a preclinical swine study. LIGHT, SCIENCE & APPLICATIONS 2017; 6:e17103. [PMID: 30167220 PMCID: PMC6062020 DOI: 10.1038/lsa.2017.103] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 06/11/2017] [Accepted: 06/14/2017] [Indexed: 05/08/2023]
Abstract
High-frequency ultrasound imaging can provide exquisite visualizations of tissue to guide minimally invasive procedures. Here, we demonstrate that an all-optical ultrasound transducer, through which light guided by optical fibers is used to generate and receive ultrasound, is suitable for real-time invasive medical imaging in vivo. Broad-bandwidth ultrasound generation was achieved through the photoacoustic excitation of a multiwalled carbon nanotube-polydimethylsiloxane composite coating on the distal end of a 300-μm multi-mode optical fiber by a pulsed laser. The interrogation of a high-finesse Fabry-Pérot cavity on a single-mode optical fiber by a wavelength-tunable continuous-wave laser was applied for ultrasound reception. This transducer was integrated within a custom inner transseptal needle (diameter 1.08 mm; length 78 cm) that included a metallic septum to acoustically isolate the two optical fibers. The use of this needle within the beating heart of a pig provided unprecedented real-time views (50 Hz scan rate) of cardiac tissue (depth: 2.5 cm; axial resolution: 64 μm) and revealed the critical anatomical structures required to safely perform a transseptal crossing: the right and left atrial walls, the right atrial appendage, and the limbus fossae ovalis. This new paradigm will allow ultrasound imaging to be integrated into a broad range of minimally invasive devices in different clinical contexts.
Collapse
|
6
|
Photodynamic therapy: Inception to application in breast cancer. Breast 2016; 31:105-113. [PMID: 27833041 DOI: 10.1016/j.breast.2016.09.016] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 09/12/2016] [Accepted: 09/26/2016] [Indexed: 01/04/2023] Open
Abstract
Photodynamic therapy (PDT) is already being used in the treatment of many cancers. This review examines its components and the new developments in our understanding of its immunological effects as well as pre-clinical and clinical studies, which have investigated its potential use in the treatment of breast cancer.
Collapse
|
7
|
Disulfonated tetraphenyl chlorin (TPCS2a)-induced photochemical internalisation of bleomycin in patients with solid malignancies: a phase 1, dose-escalation, first-in-man trial. Lancet Oncol 2016; 17:1217-29. [PMID: 27475428 DOI: 10.1016/s1470-2045(16)30224-8] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2016] [Revised: 05/25/2016] [Accepted: 06/02/2016] [Indexed: 12/12/2022]
Abstract
BACKGROUND Photochemical internalisation, a novel minimally invasive treatment, has shown promising preclinical results in enhancing and site-directing the effect of anticancer drugs by illumination, which initiates localised chemotherapy release. We assessed the safety and tolerability of a newly developed photosensitiser, disulfonated tetraphenyl chlorin (TPCS2a), in mediating photochemical internalisation of bleomycin in patients with advanced and recurrent solid malignancies. METHODS In this phase 1, dose-escalation, first-in-man trial, we recruited patients (aged ≥18 to <85 years) with local recurrent, advanced, or metastatic cutaneous or subcutaneous malignancies who were clinically assessed as eligible for bleomycin chemotherapy from a single centre in the UK. Patients were given TPCS2a on day 0 by slow intravenous injection, followed by a fixed dose of 15 000 IU/m(2) bleomycin by intravenous infusion on day 4. After 3 h, the surface of the target tumour was illuminated with 652 nm laser light (fixed at 60 J/cm(2)). The TPCS2a starting dose was 0·25 mg/kg and was then escalated in successive dose cohorts of three patients (0·5, 1·0, and 1·5 mg/kg). The primary endpoints were safety and tolerability of TPCS2a; other co-primary endpoints were dose-limiting toxicity and maximum tolerated dose. The primary analysis was per protocol. This study is registered with ClinicalTrials.gov, number NCT00993512, and has been completed. FINDINGS Between Oct 3, 2009, and Jan 14, 2014, we recruited 22 patients into the trial. 12 patients completed the 3-month follow-up period. Adverse events related to photochemical internalisation were either local, resulting from the local inflammatory process, or systemic, mostly as a result of the skin-photosensitising effect of TPCS2a. The most common grade 3 or worse adverse events were unexpected higher transient pain response (grade 3) localised to the treatment site recorded in nine patients, and respiratory failure (grade 4) noted in two patients. One dose-limiting toxicity was reported in the 1·0 mg/kg cohort (skin photosensitivity [grade 2]). Dose-limiting toxicities were reported in two of three patients at a TPCS2a dose of 1·5 mg/kg (skin photosensitivity [grade 3] and wound infection [grade 3]); thus, the maximum tolerated dose of TPCS2a was 1·0 mg/kg. Administration of TPCS2a was found to be safe and tolerable by all patients. No deaths related to photochemical internalisation treatment occurred. INTERPRETATION TPCS2a-mediated photochemical internalisation of bleomycin is safe and tolerable. We identified TPCS2a 0·25 mg/kg as the recommended treatment dose for future trials. FUNDING PCI Biotech.
Collapse
|
8
|
Music-of-light stethoscope: a demonstration of the photoacoustic effect. ACTA ACUST UNITED AC 2016; 51:045015. [PMID: 29249838 PMCID: PMC5717520 DOI: 10.1088/0031-9120/51/4/045015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Revised: 04/11/2016] [Accepted: 04/25/2016] [Indexed: 11/17/2022]
Abstract
In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on combining light excitation with ultrasound reception. Our brief was to present and explain PA imaging in a public-friendly way suitable for a variety of ages and backgrounds. We developed a simple, accessible demonstration unit using readily available materials. We used a modulated light emitting diode (LED) torch and an electronic stethoscope. The output of a music player was used for light modulation and the chest piece of the stethoscope covered by a black tape was used as an absorbing target and an enclosed chamber. This demonstration unit was presented to the public at the Bloomsbury Festival On Light in October 2015. Our stall was visited by over 100 people of varying ages. Twenty families returned in-depth evaluation questionnaires, which show that our explanations of the photoacoustic effect were well understood. Their interest in biomedical engineering was increased.
Collapse
|
9
|
Correction: Photographic-Based Optical Evaluation of Tissues and Biomaterials Used for Corneal Surface Repair: A New Easy-Applied Method. PLoS One 2015; 10:e0146205. [PMID: 26714170 PMCID: PMC4700987 DOI: 10.1371/journal.pone.0146205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
[This corrects the article DOI: 10.1371/journal.pone.0142099.].
Collapse
|
10
|
Photographic-Based Optical Evaluation of Tissues and Biomaterials Used for Corneal Surface Repair: A New Easy-Applied Method. PLoS One 2015; 10:e0142099. [PMID: 26566050 PMCID: PMC4643926 DOI: 10.1371/journal.pone.0142099] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Accepted: 10/16/2015] [Indexed: 11/19/2022] Open
Abstract
PURPOSE Tissues and biomaterials used for corneal surface repair require fulfilling specific optical standards prior to implantation in the patient. However, there is not a feasible evaluation method to be applied in clinical or Good Manufacturing Practice settings. In this study, we describe and assess an innovative easy-applied photographic-based method (PBM) for measuring functional optical blurring and transparency in corneal surface grafts. METHODS Plastic compressed collagen scaffolds (PCCS) and multilayered amniotic membranes (AM) samples were optically and histologically evaluated. Transparency and image blurring measures were obtained by PBM, analyzing photographic images of a standardized band pattern taken through the samples. These measures were compared and correlated to those obtained applying the Inverse Adding-Doubling (IAD) technique, which is the gold standard method. RESULTS All the samples used for optical evaluation by PBM or IAD were histological suitable. PCCS samples presented transmittance values higher than 60%, values that increased with increasing wavelength as determined by IAD. The PBM indicated that PCCS had a transparency ratio (TR) value of 80.3 ± 2.8%, with a blurring index (BI) of 50.6 ± 4.2%. TR and BI obtained from the PBM showed a high correlation (ρ>|0.6|) with the diffuse transmittance and the diffuse reflectance, both determined using the IAD (p<0.005). The AM optical properties showed that there was a largely linear relationship between the blurring and the number of amnion layers, with more layers producing greater blurring. CONCLUSIONS This innovative proposed method represents an easy-applied technique for evaluating transparency and blurriness of tissues and biomaterials used for corneal surface repair.
Collapse
|
11
|
Interventional Photoacoustic Imaging of the Human Placenta with Ultrasonic Tracking for Minimally Invasive Fetal Surgeries. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION : MICCAI ... INTERNATIONAL CONFERENCE ON MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION 2015; 9349:371-378. [PMID: 28101537 DOI: 10.1007/978-3-319-24553-9_46] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Image guidance plays a central role in minimally invasive fetal surgery such as photocoagulation of inter-twin placental anastomosing vessels to treat twin-to-twin transfusion syndrome (TTTS). Fetoscopic guidance provides insufficient sensitivity for imaging the vasculature that lies beneath the fetal placental surface due to strong light scattering in biological tissues. Incomplete photocoagulation of anastamoses is associated with postoperative complications and higher perinatal mortality. In this study, we investigated the use of multi-spectral photoacoustic (PA) imaging for better visualization of the placental vasculature. Excitation light was delivered with an optical fiber with dimensions that are compatible with the working channel of a fetoscope. Imaging was performed on an ex vivo normal term human placenta collected at Caesarean section birth. The photoacoustically-generated ultrasound signals were received by an external clinical linear array ultrasound imaging probe. A vein under illumination on the fetal placenta surface was visualized with PA imaging, and good correspondence was obtained between the measured PA spectrum and the optical absorption spectrum of deoxygenated blood. The delivery fiber had an attached fiber optic ultrasound sensor positioned directly adjacent to it, so that its spatial position could be tracked by receiving transmissions from the ultrasound imaging probe. This study provides strong indications that PA imaging in combination with ultrasonic tracking could be useful for detecting the human placental vasculature during minimally invasive fetal surgery.
Collapse
|
12
|
Interventional Photoacoustic Imaging of the Human Placenta with Ultrasonic Tracking for Minimally Invasive Fetal Surgeries. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION : MICCAI ... INTERNATIONAL CONFERENCE ON MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION 2015; 9349:371-378. [PMID: 28101537 DOI: 10.1007/978-3-319-24553-9] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Image guidance plays a central role in minimally invasive fetal surgery such as photocoagulation of inter-twin placental anastomosing vessels to treat twin-to-twin transfusion syndrome (TTTS). Fetoscopic guidance provides insufficient sensitivity for imaging the vasculature that lies beneath the fetal placental surface due to strong light scattering in biological tissues. Incomplete photocoagulation of anastamoses is associated with postoperative complications and higher perinatal mortality. In this study, we investigated the use of multi-spectral photoacoustic (PA) imaging for better visualization of the placental vasculature. Excitation light was delivered with an optical fiber with dimensions that are compatible with the working channel of a fetoscope. Imaging was performed on an ex vivo normal term human placenta collected at Caesarean section birth. The photoacoustically-generated ultrasound signals were received by an external clinical linear array ultrasound imaging probe. A vein under illumination on the fetal placenta surface was visualized with PA imaging, and good correspondence was obtained between the measured PA spectrum and the optical absorption spectrum of deoxygenated blood. The delivery fiber had an attached fiber optic ultrasound sensor positioned directly adjacent to it, so that its spatial position could be tracked by receiving transmissions from the ultrasound imaging probe. This study provides strong indications that PA imaging in combination with ultrasonic tracking could be useful for detecting the human placental vasculature during minimally invasive fetal surgery.
Collapse
|
13
|
Development of Photodynamic Antimicrobial Chemotherapy (PACT) for Clostridium difficile. PLoS One 2015; 10:e0135039. [PMID: 26313448 PMCID: PMC4551672 DOI: 10.1371/journal.pone.0135039] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 07/16/2015] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND Clostridium difficile is the leading cause of antibiotic-associated diarrhoea and pseudo membranous colitis in the developed world. The aim of this study was to explore whether Photodynamic Antimicrobial Chemotherapy (PACT) could be used as a novel approach to treating C. difficile infections. METHODS PACT utilises the ability of light-activated photosensitisers (PS) to produce reactive oxygen species (ROS) such as free radical species and singlet oxygen, which are lethal to cells. We screened thirteen PS against C. difficile planktonic cells, biofilm and germinating spores in vitro, and cytotoxicity of effective compounds was tested on the colorectal adenocarcinoma cell-line HT-29. RESULTS Three PS were able to kill 99.9% of bacteria in both aerobic and anaerobic conditions, both in the planktonic state and in a biofilm, after exposure to red laser light (0.2 J/cm2) without harming model colon cells. The applicability of PACT to eradicate C. difficile germinative spores indirectly was also shown, by first inducing germination with the bile salt taurocholate, followed by PACT. CONCLUSION This innovative and simple approach offers the prospect of a new antimicrobial therapy using light to treat C. difficile infection of the colon.
Collapse
|
14
|
Broadband miniature optical ultrasound probe for high resolution vascular tissue imaging. BIOMEDICAL OPTICS EXPRESS 2015; 6:1502-11. [PMID: 25909031 PMCID: PMC4399686 DOI: 10.1364/boe.6.001502] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Revised: 01/30/2015] [Accepted: 02/02/2015] [Indexed: 05/20/2023]
Abstract
An all-optical ultrasound probe for vascular tissue imaging was developed. Ultrasound was generated by pulsed laser illumination of a functionalized carbon nanotube composite coating on the end face of an optical fiber. Ultrasound was detected with a Fabry-Pérot (FP) cavity on the end face of an adjacent optical fiber. The probe diameter was < 0.84 mm and had an ultrasound bandwidth of ~20 MHz. The probe was translated across the tissue sample to create a virtual linear array of ultrasound transmit/receive elements. At a depth of 3.5 mm, the axial resolution was 64 µm and the lateral resolution was 88 µm, as measured with a carbon fiber target. Vascular tissues from swine were imaged ex vivo and good correspondence to histology was observed.
Collapse
|
15
|
Abstract
A severe complication of spinal cord injury is loss of bladder function (neurogenic bladder), which is characterized by loss of bladder sensation and voluntary control of micturition (urination), and spontaneous hyperreflexive voiding against a closed sphincter (detrusor-sphincter dyssynergia). A sacral anterior root stimulator at low frequency can drive volitional bladder voiding, but surgical rhizotomy of the lumbosacral dorsal roots is needed to prevent spontaneous voiding and dyssynergia. However, rhizotomy is irreversible and eliminates sexual function, and the stimulator gives no information on bladder fullness. We designed a closed-loop neuroprosthetic interface that measures bladder fullness and prevents spontaneous voiding episodes without the need for dorsal rhizotomy in a rat model. To obtain bladder sensory information, we implanted teased dorsal roots (rootlets) within the rat vertebral column into microchannel electrodes, which provided signal amplification and noise suppression. As long as they were attached to the spinal cord, these rootlets survived for up to 3 months and contained axons and blood vessels. Electrophysiological recordings showed that half of the rootlets propagated action potentials, with firing frequency correlated to bladder fullness. When the bladder became full enough to initiate spontaneous voiding, high-frequency/amplitude sensory activity was detected. Voiding was abolished using a high-frequency depolarizing block to the ventral roots. A ventral root stimulator initiated bladder emptying at low frequency and prevented unwanted contraction at high frequency. These data suggest that sensory information from the dorsal root together with a ventral root stimulator could form the basis for a closed-loop bladder neuroprosthetic.
Collapse
|
16
|
A randomised controlled trial of ALA vs. Photofrin photodynamic therapy for high-grade dysplasia arising in Barrett's oesophagus. Lasers Med Sci 2012; 28:707-15. [PMID: 22699800 DOI: 10.1007/s10103-012-1132-1] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2012] [Accepted: 05/31/2012] [Indexed: 02/06/2023]
Abstract
Photofrin photodynamic therapy (PDT) is a licenced treatment for Barrett's oesophagus (BE) with high-grade dysplasia (HGD) but causes strictures and photosensitivity and complete reversal of dysplasia (CR-HGD) by 50 % at 5 years. 5-Aminolaevulinic acid (ALA) is an alternative treatment with non-randomised data suggesting 85 % CR-HGD and a low risk of side effects. We aimed to compare efficacy and side effect profile between the drugs. A single-centre randomised controlled trial was conducted. Presence of HGD was confirmed on three occasions by two specialist GI pathologists. Stratification was by length of BE and extent of dysplasia. Standard protocols for ALA and Photofrin-PDT were followed. Endoscopic follow-up with 2-cm four-quadrant biopsy was at 6 weeks, 4 months, and then annually. All adverse event data were collected. Sixty four patients were randomised, 34 ALA and 30 Photofrin-PDT. Median follow-up is 24 months. On intention-to-treat analysis, CR-HGD was 16/34 (47 %) with ALA-PDT and 12/30 (40 %) with Photofrin-PDT. The overall cancer incidence was 14 % (9/64). On sub-group log-rank analysis, for BE ≤ 6 cm, CR-HGD was significantly higher with ALA-PDT than Photofrin-PDT (χ(2) =5.39, p=0.02). Strictures and skin photosensitivity were significantly more common after treatment with Photofrin-PDT than ALA-PDT (33 vs. 9 % and 43 vs. 6 %, respectively, p<0.05). The rate of buried glands with either drug was significantly higher post-PDT (48 % of patients) than pre-PDT (20 %). ALA-PDT has a better risk profile than Photofrin-PDT. In patients with BE length ≤ 6 cm, preliminary results show ALA-PDT is associated with significantly higher CR-HGD. In longer segments of BE, neither PDT drug is sufficiently efficacious to warrant routine use.
Collapse
|
17
|
The future of medical diagnostics: review paper. HEAD & NECK ONCOLOGY 2011; 3:38. [PMID: 21861912 PMCID: PMC3180646 DOI: 10.1186/1758-3284-3-38] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 08/13/2011] [Accepted: 08/23/2011] [Indexed: 12/04/2022]
Abstract
While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions.
Collapse
|
18
|
Abstract
The complete surgical removal of disease is a desirable outcome particularly in oncology. Unfortunately much disease is microscopic and difficult to detect causing a liability to recurrence and worsened overall prognosis with attendant costs in terms of morbidity and mortality. It is hoped that by advances in optical diagnostic technology we could better define our surgical margin and so increase the rate of truly negative margins on the one hand and on the other hand to take out only the necessary amount of tissue and leave more unaffected non-diseased areas so preserving function of vital structures. The task has not been easy but progress is being made as exemplified by the presentations at the 2nd Scientific Meeting of the Head and Neck Optical Diagnostics Society (HNODS) in San Francisco in January 2010. We review the salient advances in the field and propose further directions of investigation.
Collapse
|
19
|
Scanning elastic scattering spectroscopy detects metastatic breast cancer in sentinel lymph nodes. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:047001. [PMID: 20799832 PMCID: PMC2917446 DOI: 10.1117/1.3463005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A novel method for rapidly detecting metastatic breast cancer within excised sentinel lymph node(s) of the axilla is presented. Elastic scattering spectroscopy (ESS) is a point-contact technique that collects broadband optical spectra sensitive to absorption and scattering within the tissue. A statistical discrimination algorithm was generated from a training set of nearly 3000 clinical spectra and used to test clinical spectra collected from an independent set of nodes. Freshly excised nodes were bivalved and mounted under a fiber-optic plate. Stepper motors raster-scanned a fiber-optic probe over the plate to interrogate the node's cut surface, creating a 20x20 grid of spectra. These spectra were analyzed to create a map of cancer risk across the node surface. Rules were developed to convert these maps to a prediction for the presence of cancer in the node. Using these analyses, a leave-one-out cross-validation to optimize discrimination parameters on 128 scanned nodes gave a sensitivity of 69% for detection of clinically relevant metastases (71% for macrometastases) and a specificity of 96%, comparable to literature results for touch imprint cytology, a standard technique for intraoperative diagnosis. ESS has the advantage of not requiring a pathologist to review the tissue sample.
Collapse
|
20
|
Optical scanning for rapid intraoperative diagnosis of sentinel node metastases in breast cancer. Br J Surg 2010; 97:1232-9. [DOI: 10.1002/bjs.7095] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Abstract
Background
Intraoperative diagnosis of sentinel node metastases enables an immediate decision to proceed to axillary lymph node dissection, avoiding a second operation in node-positive women with breast cancer.
Methods
An optical scanner was developed that interrogated the cut surface of bivalved, but otherwise unprocessed, sentinel lymph nodes with pulses of white light by elastic scattering spectroscopy (ESS). The scattered light underwent spectral analysis, and individual spectra were initially correlated with conventional histology to develop a diagnostic algorithm. This algorithm was used to create false colour-coded maps of scans from an independent set of nodes, and the optimal criteria for discriminating between normal and cancer spectra were defined statistically.
Results
The discriminant algorithm was developed from a training set of 2989 spectra obtained from 30 metastatic and 331 normal nodes. Subsequent scans from 129 independent nodes were analysed. The scanner detected macrometastases (larger than 2 mm) with a sensitivity of 76 per cent (69 per cent including micrometastases) and specificity of 96 per cent.
Conclusion
In this proof-of-principle study, the ESS results were comparable with current intraoperative diagnostic techniques of lymph node assessment.
Collapse
|
21
|
Image cytometry accurately detects DNA ploidy abnormalities and predicts late relapse to high-grade dysplasia and adenocarcinoma in Barrett's oesophagus following photodynamic therapy. Br J Cancer 2010; 102:1608-17. [PMID: 20461081 PMCID: PMC2883155 DOI: 10.1038/sj.bjc.6605688] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Background and aims: DNA ploidy abnormalities (aneuploidy/tetraploidy) measured by flow cytometry (FC) are strong predictors of future cancer development in untreated Barrett's oesophagus, independent of histology grade. Image cytometric DNA analysis (ICDA) is an optical technique allowing visualisation of abnormal nuclei that may be undertaken on archival tissue. Our aim was to determine the accuracy of ICDA vs FC, and evaluate DNA ploidy as a prognostic biomarker after histologically successful treatment with photodynamic therapy (PDT). Methods: Nuclei were extracted from 40 μm sections of paraffin-embedded biopsies and processed for ICDA at UCL and FC at UW using standardised protocols. Subsequently, DNA ploidy was evaluated by ICDA on a cohort of 30 patients clear of dysplasia 1 year after aminolaevulinic acid PDT for high-grade dysplasia (HGD). The results were correlated with long-term outcome. Results: In the comparative study, 93% (41 out of 44) of cases were classified identically. Errors occurred in the near-diploid region by ICDA and the tetraploid region by FC. In the cohort study, there were 13 cases of late relapse (7 cancer, 6 HGD) and 17 patients who remained free of dysplasia after a mean follow-up of 44 months. Aneuploidy post-PDT was highly predictive for recurrent HGD or cancer with a hazard ratio of 8.2 (1.8–37.8) (log-rank P=0.001). Conclusions: ICDA is accurate for the detection of DNA ploidy abnormalities when compared with FC. After histologically successful PDT, patients with residual aneuploidy are significantly more likely to develop HGD or cancer than those who become diploid. DNA ploidy by ICDA is a valuable prognostic biomarker after ablative therapy.
Collapse
|
22
|
Effective photoinactivation of Gram-positive and Gram-negative bacterial strains using an HIV-1 Tat peptide–porphyrin conjugate. Photochem Photobiol Sci 2010; 9:1613-20. [DOI: 10.1039/c0pp00146e] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
23
|
T lymphocyte subset abnormalities in the blood and lung in pulmonary arterial hypertension. Respir Med 2009; 104:454-62. [PMID: 19880300 DOI: 10.1016/j.rmed.2009.10.004] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2009] [Revised: 08/16/2009] [Accepted: 10/05/2009] [Indexed: 10/20/2022]
Abstract
RATIONALE Mounting data suggest that immune cell abnormalities participate in the pathogenesis of pulmonary arterial hypertension (PAH). OBJECTIVE To determine whether the T lymphocyte subset composition in the systemic circulation and peripheral lung is altered in PAH. METHODS Flow cytometric analyses were performed to determine the phenotypic profile of peripheral blood lymphocytes in idiopathic PAH (IPAH) patients (n=18) and healthy controls (n=17). Immunocytochemical analyses of lymphocytes and T cell subsets were used to examine lung tissue from PAH patients (n=11) and controls (n=11). MEASUREMENTS AND MAIN RESULTS IPAH patients have abnormal CD8+ T lymphocyte subsets, with a significant increase in CD45RA+ CCR7- peripheral cytotoxic effector-memory cells (p=0.02) and reduction of CD45RA+ CCR7+ naive CD8+ cells versus controls (p=0.001). Further, IPAH patients have a higher proportion of circulating regulatory T cells (T(reg)) and 4-fold increases in the number of CD3+ and CD8+ cells in the peripheral lung compared with controls (p<0.01). CONCLUSIONS Alterations in circulating T cell subsets, particularly CD8+ T lymphocytes and CD4+ T(reg), in patients with PAH suggest that a dysfunctional immune system contributes to disease pathogenesis. A preponderance of CD3+ and CD8+ T lymphocytes in the peripheral lung of PAH patients supports this concept.
Collapse
|
24
|
Abstract
BACKGROUND Traditionally, intraperitoneal bladder perforations caused by trauma or iatrogenic interventions have been treated by open or laparoscopic surgery. Additionally, transvesical access to the peritoneal cavity has been reported to be feasible and useful for natural orifice translumenal endoscopic surgery (NOTES) but would be enhanced by a reliable method of closing the vesicotomy. OBJECTIVE To assess the feasibility and safety of an endoscopic closure method for vesical perforations using a flexible, small-diameter endoscopic suturing kit in a survival porcine model. DESIGN, SETTING, AND PARTICIPANTS This pilot study was performed at the University of Minho, Braga, Portugal, using six anesthetized female pigs. INTERVENTIONS Closure of a full-thickness longitudinal incision in the bladder dome (up to 10 mm in four animals and up to 20 mm in two animals) with the endoscopic suturing kit using one to three absorbable stitches. MEASUREMENTS The acute quality of sealing was immediately tested by distending the bladder with methylene-blue dye under laparoscopic control (in two animals). Without a bladder catheter, the animals were monitored daily for 2 wk, and a necropsy examination was performed to check for the signs of peritonitis, wound dehiscence, and quality of healing. RESULTS AND LIMITATIONS Endoscopic closure of bladder perforation was carried out easily and quickly in all animals. The laparoscopic view revealed no acute leak of methylene-blue dye after distension of the bladder. After recovery from anaesthesia, the pigs began to void normally, and no adverse event occurred. Postmortem examination revealed complete healing of vesical incision with no signs of infection or adhesions in the peritoneal cavity. No limitations have yet been studied clinically. CONCLUSIONS This study demonstrates the feasibility and the safety of endoscopic closure of vesical perforations with an endoscopic suturing kit in a survival porcine model. This study provides support for further studies using endoscopic closure of the bladder which may lead to a new era in management of bladder rupture and adoption of the transvesical port in NOTES procedures.
Collapse
|
25
|
Abstract
BACKGROUND AND STUDY AIMS Endoscopic ultrasound and fine-needle aspiration of paramural lesions are established diagnostic techniques in gastroenterology and are now also used for therapeutic purposes. The proximity of the heart to the esophagus and the utility of the diagnostic technique of transesophageal echography prompted us to explore the possibilities of approaching the heart through the esophagus. METHODS In acute experiments (n = 2) and survival experiments (n = 6) on anesthetized pigs, the anatomical landmarks were first identified and studied, before introduction of the needle through the posterior cardiac wall into the left atrium, and then beyond, as far as the aortic valve. The smallest structure targeted was the coronary artery. The animals in the survival group were monitored clinically over a 2-week period and also underwent endoscopic and cardiologic re-examinations prior to autopsy. Three patients were also investigated using the technique. RESULTS No visible damage was observed in the heart in the two animals which were sacrificed immediately or in the six surviving pigs (except for one small hematoma). The needle could be introduced repeatedly into the left atrium, followed by the injection of saline. Reaching the aortic valve was more difficult because of the moving target, but ablation therapy was technically possible. The coronary artery was successfully punctured in three of the animals (all three weighed 40 kg or more); in smaller animals, the needle overshot the lumen of these minute arteries. Of the three patients investigated, pericardial fluid was successfully aspirated in two patients and a left atrial mass was punctured in the third patient (excluding neoplasia, the final diagnosis being thrombus). CONCLUSION These animal studies and clinical cases suggest that transesophageal intracardiac procedures could become feasible and that further exploration by gastroenterologists and cardiologists may be justified.
Collapse
|
26
|
Photodynamic therapy using meso tetra hydroxy phenyl chlorin (mTHPC) in early prostate cancer. Lasers Surg Med 2007; 38:356-63. [PMID: 16392142 DOI: 10.1002/lsm.20275] [Citation(s) in RCA: 125] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND AND OBJECTIVES Prostate cancer is increasing in incidence, but current treatments including surgery and radiotherapy have significant side effects. This pilot study was designed to assess the potential of photodynamic therapy (PDT) using meso tetra hydroxy phenyl chlorin (mTHPC) for organ confined prostate cancer. STUDY DESIGN/PATIENTS AND METHODS Six men with organ confined prostate cancer were photosensitised with mTHPC (0.15 mg/kg). Between 2 and 5 days later, red light (652 nm) was delivered to areas of biopsy proven cancer via fibres inserted through transperineal needles (50-100 J per site). RESULTS After 8 of 10 PDT sessions, the prostate specific antigen (PSA) fell by up to 67%. Early MRI scans showed oedema and patchy necrosis, which resolved over 2 months. Biopsies of treated areas revealed necrosis and fibrosis at 1-2 months. CONCLUSIONS PDT for primary prostate cancer appears safe and can reduce PSA levels. As this was a phase I study, no attempt was made to treat the whole prostate; this or targeted tumour ablation could be attempted in a phase II study with an increased number of fibres. This technique merits further investigation in early prostate cancer.
Collapse
|
27
|
|
28
|
A system to monitor for fibre breakage during photodynamic therapy with diffuser fibres. Lasers Med Sci 2003; 18:162-4. [PMID: 14505200 DOI: 10.1007/s10103-003-0270-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2002] [Accepted: 07/21/2003] [Indexed: 10/26/2022]
Abstract
There is concern that the delicate fibres and cylindrical diffuser tips used for intraluminal PDT of blood vessels might break during the treatment. We have developed and tested a simple system to monitor for fibre breakage during PDT. Light from the laser is passed through a beam expander, then a beam splitter, and then is again contracted into the inlet of a diffuser fibre. Light reflected from the distal diffuser is also partially reflected by the beam splitter into a photodiode, which monitors changes in the intensity of the reflected light. The system was tested by simulating catastrophic failures in four fibres. In each case the output fell very significantly (DV=0.44-1.68 V, SD=0.01 V). Despite the small statistical sample, the average change in the reflected light intensity is still significant (p < 0.025, paired Student's t-test). Our conclusion was that this device can monitor the integrity of diffuser fibres during PDT.
Collapse
|
29
|
Tyrosinase degradation via two pathways during reverse translocation to the cytosol. Biochem Biophys Res Commun 2001; 285:313-9. [PMID: 11444844 DOI: 10.1006/bbrc.2001.5153] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Previous studies established that after inhibition of proteasome activity, tyrosinase could be detected in the cytosol after initial translation in the endoplasmic reticulum (ER), with a molecular weight consistent with that of a full-length, deglycosylated polypeptide. Here we show that most of these molecules are glycosylated, but have been proteolyzed at the carboxyl terminus by a protease that is insensitive to proteasome inhibitors. We also demonstrate the inhibitor-dependent accumulation of a membrane species that appears structurally homologous to the glycosylated and partially proteolyzed cytosolic form. Under some circumstances, cytosolic tyrosinase that had been deglycosylated and not proteolyzed prior to proteasomal degradation could also be detected. The presence of cytosolic tyrosinase was dependent upon glycosylation of the molecule during synthesis in the ER. These results suggest the existence of at least two alternative pathways for degradation of tyrosinase in the cytosol.
Collapse
|
30
|
Abstract
BACKGROUND Methods are needed for propulsion of endoscopes and wireless video capsules along the small intestine. This work aims to test the hypothesis that electrical stimulation could propel an endoscope by stimulating muscular contraction. METHODS Prototype acrylic ovoid-shaped devices were constructed with 2 stainless steel electrodes mounted on the tapered section. Five devices 15 to 23 mm diameter with a taper of 28 degrees to 40 degrees (included angle) were tested. When these devices were in contact with the bowel wall, electrostimulation was applied causing circular muscle contraction, which when applied to the taper of the ovoid resulted in forward propulsion of the device. The method does not induce peristalsis but works by stimulating local contraction. The device was tested in the small intestine and esophagus of anesthetized pigs. RESULTS Electrostimulation caused the ovoid to advance rapidly (6 mm/sec) up and down the esophagus by inducing circular esophageal muscle contraction. When stimulated at 15 Hz with 30-ms pulses, the threshold for movement in the small intestine was 12 mA; at 20 mA the device moved reliably in either direction in the small intestine at speeds of up to 4.5 mm/sec and negotiated tight curves. CONCLUSION Electrostimulation can move endoscopes in the small intestine.
Collapse
|
31
|
Abstract
BACKGROUND The widely varying forces used at colonoscopy have not been measured. An electronic device was designed to measure the forces exerted by the clinician on the endoscope during colonoscopy. METHODS The device featured a handle designed in the shape of a hinged split cylinder that could be locked around the endoscope but readily moved up and down the insertion tube as the colonoscopy proceeded. This cylinder contained strain-gauges arranged so that the forces transmitted could be accurately measured. The device recorded the torque forces in addition to the push and pull forces exerted during diagnostic colonoscopy. RESULTS In a series of 21 colonoscopies in 20 patients: peak pushing force = 4.4 kg, pulling force = -1.8 kg, anti-clockwise torque = 1.0 Newton meters, clockwise torque = 0.8 Newton meters. Percentage time force greater than 1 kg = 5%. Peak anal insertion force = 1.8 kg. CONCLUSIONS These measurements represent the first accurate measurements of the forces exerted during colonoscopy. Reducing the force during colonoscopy is likely to diminish pain and reduce the risk of perforation. A knowledge of these forces may also help with the design of new instruments and models for teaching or research.
Collapse
|
32
|
Technical advances and experimental devices for enteroscopy. Gastrointest Endosc Clin N Am 1999; 9:145-61. [PMID: 9834323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Enteroscopy remains the procedure in the gastrointestinal tract that is most inaccessible to endoscopy, and technical limitations severely impair the ability to advance and examine the small bowel reliably or completely. Push-type enteroscopy not only suffers limitations owing to looping in the stomach, but is intrinsically associated with increasing loss of transmission of force to the tip and consequent failure of advancement. Development is this area has been slow, partly owing to the limited clinical need compared with upper gastrointestinal endoscopy, and colonoscopy and consequent financial limitations imposed on further development. Practical and useful technical advances have been made, especially in push-type as well as sonde-type enteroscopy. These are reviewed briefly and are covered in other articles elsewhere in this issue.
Collapse
|
33
|
Device for measuring the forces exerted on the shaft of an endoscope during colonoscopy. Med Biol Eng Comput 1998; 36:186-90. [PMID: 9684458 DOI: 10.1007/bf02510741] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Colonoscopy involves advancing a flexible endoscope into and along the entire length of the colon. The procedure can be painful and carries the risk of perforating the organ, yet very little is known of the forces involved. A device to measure the forces exerted on the endoscope during colonoscopy is described. The device features a handle designed in the shape of a hinged split cylinder that locks around the endoscope, gripping it tightly. The handle has two parts, an inner part that grips the endoscope, and an outer part that is gripped by the endoscopist. The two parts are joined together by members that transmit the forces through to the endoscope. One of the members incorporates strain gauges that measure the torque applied to the endoscope, as well as the push and pull forces. The handle can easily be unlocked and moved along the endoscope as the colonoscopy proceeds. The device is used to measure the forces applied to the endoscope during 11 routine colonoscopies, and summary results are presented. These are believed to be the first accurate measurements of the forces exerted during colonoscopy.
Collapse
|
34
|
The class I antigen-processing pathway for the membrane protein tyrosinase involves translation in the endoplasmic reticulum and processing in the cytosol. J Exp Med 1998; 187:37-48. [PMID: 9419209 PMCID: PMC2199193 DOI: 10.1084/jem.187.1.37] [Citation(s) in RCA: 101] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/1997] [Revised: 10/22/1997] [Indexed: 02/05/2023] Open
Abstract
Formation of major histocompatibility complex class I-associated peptides from membrane proteins has not been thoroughly investigated. We examined the processing of an HLA-A*0201-associated epitope, YMDGTMSQV, that is derived from the membrane protein tyrosinase by posttranslational conversion of the sequence YMNGTMSQV. Only YMDGTMSQV and not YMNGTMSQV was presented by HLA-A*0201 on cells expressing full-length tyrosinase, although both peptides have similar affinities for HLA-A*0201 and are transported by TAP. In contrast, translation of YMNGTMSQV in the cytosol, as a minigene or a larger fragment of tyrosinase, led to the presentation of the unconverted YMNGTMSQV. This was not due to overexpression leading to saturation of the processing/conversion machinery, since presentation of the converted peptide, YMDGTMSQV, was low or undetectable. Thus, presentation of unconverted peptide was associated with translation in the cytosol, suggesting that processing of the full-length tyrosinase occurs after translation in the endoplasmic reticulum. Nevertheless, presentation of YMDGTMSQV in cells expressing full-length tyrosinase was TAP (transporter associated with antigen processing) and proteasome dependent. After inhibition of proteasome activity, tyrosinase species could be detected in the cytosol. We propose that processing of tyrosinase involves translation in the endoplasmic reticulum, export of full-length tyrosinase to the cytosol, and retransport of converted peptides by TAP for association with HLA-A*0201.
Collapse
|
35
|
Computer-generated titanium cranioplasty: report of a new technique for repairing skull defects. Br J Neurosurg 1992; 6:343-50. [PMID: 1388828 DOI: 10.3109/02688699209023793] [Citation(s) in RCA: 53] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
A review of 40 cases of titanium cranioplasty fabricated from impressions taken of the defect through the patient's scalp in the conventional way showed that 23% were ill-fitting and 41% of frontal plates had a poor aesthetic result. Attributable factors were difficulty in defining the defect border accurately and limited information of the surrounding tissue architecture which led to strains produced during insertion. Inadequate communication between surgeon and prosthetist compounded these difficulties. A prospective study of six cases fabricated from CT computer-generated models of challenging cranial defects appears to show significant improvements in plate design, resulting in better plate adaptation, stability and aesthetic contour. Plate insertion was rapid (mean time 27 min) thereby minimizing operating time. This paper also discusses the advantages of the enhanced information derived from CT and describes the potential for pre-craniotomy template and matching cranioplasty, thereby permitting a one-stage procedure.
Collapse
|
36
|
Abstract
A simple and inexpensive capacitive sensor which fits around any normal drip chamber has been devised. When it is made part of a suitable AC bridge circuit, the small changes in capacitance caused by the presence of a drop between the sensor plates can be reliably detected. The sensor is insensitive to its position on the drip chamber or to tilt of the chamber and unlike optical drop sensors, it is insensitive to ambient lighting.
Collapse
|
37
|
|
38
|
A system for the continuous measurement of oxygen uptake and carbon dioxide output in artificially ventilated patients. Br J Anaesth 1983; 55:791-800. [PMID: 6411106 DOI: 10.1093/bja/55.8.791] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
A continuous, non-invasive system is described for measuring oxygen uptake (VO2) and carbon dioxide output (VCO2) in mechanically ventilated patients. Inspiratory and mixed expiratory gas samples were pumped through fine-bore tubing to a remote mass spectrometer for analysis. The expiratory flow transducer of a Siemens Servo 900B ventilator was used for expiratory flow measurement and inspiratory flow was calculated from this using the Haldane transformation. A desk-top computer calculated VO2, VCO2 and respiratory quotient. The system has been validated against standard methods of gas analysis and flow measurement (VO2 mean difference -10 ml min-1: SD 9.13; VCO2 mean difference 8.12 ml min-1: SD 4.66). Comparison with Douglas bag measurements in patients has been made (VO2 mean difference 10.7 ml min-1: SD 9.8; VCO2 mean difference -1.07 ml min-1: SD 4.7).
Collapse
|
39
|
Abstract
The accuracy and linearity of three Siemens Servo 900B expiratory flowmeters have been assessed by comparison with a dry gas meter. Their performance was reassessed after 792,966 and 950 h respectively. The effects of changes in respiratory rate, relative humidity and oxygen concentration on the meters were studied. It was found that the meters were accurate and linear and that reliable measurements could still be made after long periods of continuous use. The meters were found to be less accurate at low respiratory rates. Relative humidity had little effect on flow measurement. Changes in oxygen concentration, and hence viscosity, led to errors of up to 16% in flow measurement.
Collapse
|
40
|
|