1
|
Physiologic validation of the compensatory reserve metric obtained from pulse oximetry: A step towards advanced medical monitoring on the battlefield. J Trauma Acute Care Surg 2024:01586154-990000000-00733. [PMID: 38745348 DOI: 10.1097/ta.0000000000004377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
BACKGROUND The Compensatory Reserve Metric (CRM) provides a time sensitive indicator of hemodynamic decompensation. However, its in-field utility is limited due to the size and cost-intensive nature of standard vital sign monitors or photoplethysmographic volume-clamp (PPGVC) devices used to measure arterial waveforms. In this regard, photoplethysmographic measurements obtained from pulse oximetry (PPGPO) may serve as a useful, portable alternative. This study aimed to validate CRM values obtained using PPGPO. METHODS Forty-nine healthy adults (25 females) underwent a graded lower body negative pressure (LBNP) protocol to simulate hemorrhage. Arterial waveforms were sampled using PPGPO and PPGVC. The CRM was calculated using a one-dimensional convolutional neural network. Cardiac output and stroke volume were measured using PPGVC. A brachial artery catheter was used to measure intraarterial pressure. A 3-lead ECG was used to measure heart rate. Fixed-effect linear mixed models with repeated measures were used to examine the association between CRM values and physiologic variables. Log-rank analyses were used to examine differences in shock determination during LBNP between monitored hemodynamic parameters. RESULTS The median LBNP stage reached was 70 mmHg (Range: 45-100 mmHg). Relative to baseline, at tolerance there was a 47±12% reduction in stroke volume, 64±27% increase in heart rate, and 21±7% reduction in systolic blood pressure (P<0.001 for all). CRM values obtained with both PPGPO and PPGVC were associated with changes in heart rate (P<0.001), stroke volume (P<0.001), and pulse pressure (P<0.001). Furthermore, they provided an earlier detection of hemodynamic shock relative to the traditional metrics of shock index (P<0.001 for both), systolic blood pressure (P<0.001 for both), and heart rate (P=0.001 for both). CONCLUSION The CRM obtained from PPGPO provides a valid, time-sensitized prediction of hemodynamic decompensation, opening the door to provide military medical personnel noninvasive in-field advanced capability for early detection of hemorrhage and imminent onset of shock. LEVEL OF EVIDENCE Diagnostic Tests or Criteria, Level IV.
Collapse
|
2
|
Artificial Intelligence Support for Informal Patient Caregivers: A Systematic Review. Bioengineering (Basel) 2024; 11:483. [PMID: 38790350 PMCID: PMC11118398 DOI: 10.3390/bioengineering11050483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 05/05/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024] Open
Abstract
This study aims to explore how artificial intelligence can help ease the burden on caregivers, filling a gap in current research and healthcare practices due to the growing challenge of an aging population and increased reliance on informal caregivers. We conducted a search with Google Scholar, PubMed, Scopus, IEEE Xplore, and Web of Science, focusing on AI and caregiving. Our inclusion criteria were studies where AI supports informal caregivers, excluding those solely for data collection. Adhering to PRISMA 2020 guidelines, we eliminated duplicates and screened for relevance. From 947 initially identified articles, 10 met our criteria, focusing on AI's role in aiding informal caregivers. These studies, conducted between 2012 and 2023, were globally distributed, with 80% employing machine learning. Validation methods varied, with Hold-Out being the most frequent. Metrics across studies revealed accuracies ranging from 71.60% to 99.33%. Specific methods, like SCUT in conjunction with NNs and LibSVM, showcased accuracy between 93.42% and 95.36% as well as F-measures spanning 93.30% to 95.41%. AUC values indicated model performance variability, ranging from 0.50 to 0.85 in select models. Our review highlights AI's role in aiding informal caregivers, showing promising results despite different approaches. AI tools provide smart, adaptive support, improving caregivers' effectiveness and well-being.
Collapse
|
3
|
Comparing the compensatory reserve metric obtained from invasive arterial measurements and photoplethysmographic volume-clamp during simulated hemorrhage. J Clin Monit Comput 2024:10.1007/s10877-024-01166-x. [PMID: 38733507 DOI: 10.1007/s10877-024-01166-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 04/16/2024] [Indexed: 05/13/2024]
Abstract
PURPOSE The compensatory reserve metric (CRM) is a novel tool to predict cardiovascular decompensation during hemorrhage. The CRM is traditionally computed using waveforms obtained from photoplethysmographic volume-clamp (PPGVC), yet invasive arterial pressures may be uniquely available. We aimed to examine the level of agreement of CRM values computed from invasive arterial-derived waveforms and values computed from PPGVC-derived waveforms. METHODS Sixty-nine participants underwent graded lower body negative pressure to simulate hemorrhage. Waveform measurements from a brachial arterial catheter and PPGVC finger-cuff were collected. A PPGVC brachial waveform was reconstructed from the PPGVC finger waveform. Thereafter, CRM values were computed using a deep one-dimensional convolutional neural network for each of the following source waveforms; (1) invasive arterial, (2) PPGVC brachial, and (3) PPGVC finger. Bland-Altman analyses were used to determine the level of agreement between invasive arterial CRM values and PPGVC CRM values, with results presented as the Mean Bias [95% Limits of Agreement]. RESULTS The mean bias between invasive arterial- and PPGVC brachial CRM values at rest, an applied pressure of -45mmHg, and at tolerance was 6% [-17%, 29%], 1% [-28%, 30%], and 0% [-25%, 25%], respectively. Additionally, the mean bias between invasive arterial- and PPGVC finger CRM values at rest, applied pressure of -45mmHg, and tolerance was 2% [-22%, 26%], 8% [-19%, 35%], and 5% [-15%, 25%], respectively. CONCLUSION There is generally good agreement between CRM values obtained from invasive arterial waveforms and values obtained from PPGVC waveforms. Invasive arterial waveforms may serve as an alternative for computation of the CRM.
Collapse
|
4
|
Artificial Intelligence Algorithms for Expert Identification in Medical Domains: A Scoping Review. Eur J Investig Health Psychol Educ 2024; 14:1182-1196. [PMID: 38785576 PMCID: PMC11119077 DOI: 10.3390/ejihpe14050078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2024] [Revised: 04/11/2024] [Accepted: 04/25/2024] [Indexed: 05/25/2024] Open
Abstract
With abundant information and interconnectedness among people, identifying knowledgeable individuals in specific domains has become crucial for organizations. Artificial intelligence (AI) algorithms have been employed to evaluate the knowledge and locate experts in specific areas, alleviating the manual burden of expert profiling and identification. However, there is a limited body of research exploring the application of AI algorithms for expert finding in the medical and biomedical fields. This study aims to conduct a scoping review of existing literature on utilizing AI algorithms for expert identification in medical domains. We systematically searched five platforms using a customized search string, and 21 studies were identified through other sources. The search spanned studies up to 2023, and study eligibility and selection adhered to the PRISMA 2020 statement. A total of 571 studies were assessed from the search. Out of these, we included six studies conducted between 2014 and 2020 that met our review criteria. Four studies used a machine learning algorithm as their model, while two utilized natural language processing. One study combined both approaches. All six studies demonstrated significant success in expert retrieval compared to baseline algorithms, as measured by various scoring metrics. AI enhances expert finding accuracy and effectiveness. However, more work is needed in intelligent medical expert retrieval.
Collapse
|
5
|
The usefulness of artificial intelligence in breast reconstruction: a systematic review. Breast Cancer 2024:10.1007/s12282-024-01582-6. [PMID: 38619786 DOI: 10.1007/s12282-024-01582-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Accepted: 03/30/2024] [Indexed: 04/16/2024]
Abstract
BACKGROUND Artificial Intelligence (AI) offers an approach to predictive modeling. The model learns to determine specific patterns of undesirable outcomes in a dataset. Therefore, a decision-making algorithm can be built based on these patterns to prevent negative results. This systematic review aimed to evaluate the usefulness of AI in breast reconstruction. METHODS A systematic review was conducted in August 2022 following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. MEDLINE, EMBASE, SCOPUS, and Google Scholar online databases were queried to capture all publications studying the use of artificial intelligence in breast reconstruction. RESULTS A total of 23 studies were full text-screened after removing duplicates, and twelve articles fulfilled our inclusion criteria. The Machine Learning algorithms applied for neuropathic pain, lymphedema diagnosis, microvascular abdominal flap failure, donor site complications associated to muscle sparing Transverse Rectus Abdominis flap, surgical complications, financial toxicity, and patient-reported outcomes after breast surgery demonstrated that AI is a helpful tool to accurately predict patient results. In addition, one study used Computer Vision technology to assist in Deep Inferior Epigastric Perforator Artery detection for flap design, considerably reducing the preoperative time compared to manual identification. CONCLUSIONS In breast reconstruction, AI can help the surgeon by optimizing the perioperative patients' counseling to predict negative outcomes, allowing execution of timely interventions and reducing the postoperative burden, which leads to obtaining the most successful results and improving patient satisfaction.
Collapse
|
6
|
Stability of One-Step Spray-on Splint for Lower Extremity Fractures During Splinting, MEDEVAC, and Impact. Mil Med 2024:usae001. [PMID: 38294066 DOI: 10.1093/milmed/usae001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 10/26/2023] [Accepted: 01/08/2024] [Indexed: 02/01/2024] Open
Abstract
INTRODUCTION Military transport can induce whole-body vibrations, and combat almost always involves high impact between lower extremities and the ground. Therefore, robust splinting technology is necessary for lower extremity fractures in these settings. Our team compared a novel one-step spray-on foam splint (FastCast) to the current military standard structured aluminum malleable (SAM) splint. MATERIALS AND METHODS Ten cadaveric specimens were subjected to complete tibia/fibula osteotomy. Specimens were fitted with custom accelerometer and gyroscope sensors superior and inferior to the fracture line. Each specimen underwent fracture and splinting from a standard of care SAM splint and an experimental FastCast spray foam splint in a randomized order. Each specimen was manually transported to an ambulance and then released from a 1 meter height to simulate impact. The custom sensors recorded accelerations and rotations throughout each event. Repeated-measures Friedman tests were used to assess differences between splint method within each event and between sensors within each splint method. RESULTS During splinting, overall summation of change and difference of change between sensors for accelerations and rotations were greater for SAM splints than FastCast across all axes (P ≤ 0.03). During transport, the range of acceleration along the linear superior/inferior axis was greater for SAM splint than FastCast (P = 0.02), as was the range of rotation along the transverse plane (P < 0.01). On impact, the summation of change observed was greater for SAM splint than FastCast with respect to acceleration and rotation on the posterior/anterior and superior/inferior axes (P ≤ 0.03), and the cumulative difference between superior and inferior sensors was greater for SAM than FastCast with respect to anterior-axis rotation (P < 0.05). CONCLUSION FastCast maintains stabilization of fractured lower extremities during transport and impacts to a significantly greater extent than SAM splints. Therefore, FastCast can potentially reduce the risk of fracture complications following physical stressors associated with combat and extraction.
Collapse
|
7
|
Machine Learning Algorithms Predict Long-Term Postoperative Opioid Misuse: A Systematic Review. Am Surg 2024; 90:140-151. [PMID: 37732536 DOI: 10.1177/00031348231198112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
INTRODUCTION A steadily rising opioid pandemic has left the US suffering significant social, economic, and health crises. Machine learning (ML) domains have been utilized to predict prolonged postoperative opioid (PPO) use. This systematic review aims to compile all up-to-date studies addressing such algorithms' use in clinical practice. METHODS We searched PubMed/MEDLINE, EMBASE, CINAHL, and Web of Science using the keywords "machine learning," "opioid," and "prediction." The results were limited to human studies with full-text availability in English. We included all peer-reviewed journal articles that addressed an ML model to predict PPO use by adult patients. RESULTS Fifteen studies were included with a sample size ranging from 381 to 112898, primarily orthopedic-surgery-related. Most authors define a prolonged misuse of opioids if it extends beyond 90 days postoperatively. Input variables ranged from 9 to 23 and were primarily preoperative. Most studies developed and tested at least two algorithms and then enhanced the best-performing model for use retrospectively on electronic medical records. The best-performing models were decision-tree-based boosting algorithms in 5 studies with AUC ranging from .81 to .66 and Brier scores ranging from .073 to .13, followed second by logistic regression classifiers in 5 studies. The topmost contributing variable was preoperative opioid use, followed by depression and antidepressant use, age, and use of instrumentation. CONCLUSIONS ML algorithms have demonstrated promising potential as a decision-supportive tool in predicting prolonged opioid use in post-surgical patients. Further validation studies would allow for their confident incorporation into daily clinical practice.
Collapse
|
8
|
Benefits and Challenges of Remote Patient Monitoring as Perceived by Health Care Practitioners: A Systematic Review. Perm J 2023; 27:100-111. [PMID: 37735970 PMCID: PMC10730976 DOI: 10.7812/tpp/23.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
BACKGROUND Remote patient monitoring (RPM), or telemonitoring, offers ways for health care practitioners to gather real-time information on the physiological conditions of patients. As telemedicine, and thus telemonitoring, is becoming increasingly relevant in today's society, understanding the practitioners' opinions is crucial. This systematic review evaluates the perspectives and experiences of health care practitioners with telemonitoring technologies. METHODS A database search was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines for the selection of articles measuring health care practitioners' perspectives and experiences with RPM technologies published between 2017 and 2021. Only articles written in English were included. No statistical analysis was performed and thus this is a qualitative review. RESULTS A total of 1605 studies were identified after the initial search. After applying the inclusion and exclusion criteria of this review's authors, 13 articles were included in this review. In all, 2351 practitioners' perspectives and experience utilizing RPM technology in a variety of medical specialties were evaluated through close- and open-ended surveys. Recurring themes emerged for both the benefits and challenges. Common benefits included continuous monitoring of patients to provide prompt care, improvement of patient self-care, efficient communication, increased patient confidence, visualization of health trends, and greater patient education. Challenges comprised increased workload, higher patient anxiety, data inaccuracy, disorienting technology, financial issues, and privacy concerns. CONCLUSION Health care practitioners generally believe that RPM is feasible for application. Additionally, there is a consensus that telemonitoring strategies will become increasingly relevant. However, there are still drawbacks to the technology that need to be considered.
Collapse
|
9
|
Verification and Validation of Lower Body Negative Pressure as a Non-Invasive Bioengineering Tool for Testing Technologies for Monitoring Human Hemorrhage. Bioengineering (Basel) 2023; 10:1226. [PMID: 37892956 PMCID: PMC10604311 DOI: 10.3390/bioengineering10101226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/02/2023] [Accepted: 10/08/2023] [Indexed: 10/29/2023] Open
Abstract
Since hemorrhage is a leading cause of preventable death in both civilian and military settings, the development of advanced decision support monitoring capabilities is necessary to promote improved clinical outcomes. The emergence of lower body negative pressure (LBNP) has provided a bioengineering technology for inducing progressive reductions in central blood volume shown to be accurate as a model for the study of the early compensatory stages of hemorrhage. In this context, the specific aim of this study was to provide for the first time a systematic technical evaluation to meet a commonly accepted engineering standard based on the FDA-recognized Standard for Assessing Credibility of Modeling through Verification and Validation (V&V) for Medical Devices (ASME standard V&V 40) specifically highlighting LBNP as a valuable resource for the safe study of hemorrhage physiology in humans. As an experimental tool, evidence is presented that LBNP is credible, repeatable, and validated as an analog for the study of human hemorrhage physiology compared to actual blood loss. The LBNP tool can promote the testing and development of advanced monitoring algorithms and evaluating wearable sensors with the goal of improving clinical outcomes during use in emergency medical settings.
Collapse
|
10
|
Artificial Intelligence Models in Health Information Exchange: A Systematic Review of Clinical Implications. Healthcare (Basel) 2023; 11:2584. [PMID: 37761781 PMCID: PMC10531020 DOI: 10.3390/healthcare11182584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 09/14/2023] [Accepted: 09/16/2023] [Indexed: 09/29/2023] Open
Abstract
Electronic health record (EHR) systems collate patient data, and the integration and standardization of documents through Health Information Exchange (HIE) play a pivotal role in refining patient management. Although the clinical implications of AI in EHR systems have been extensively analyzed, its application in HIE as a crucial source of patient data is less explored. Addressing this gap, our systematic review delves into utilizing AI models in HIE, gauging their predictive prowess and potential limitations. Employing databases such as Scopus, CINAHL, Google Scholar, PubMed/Medline, and Web of Science and adhering to the PRISMA guidelines, we unearthed 1021 publications. Of these, 11 were shortlisted for the final analysis. A noticeable preference for machine learning models in prognosticating clinical results, notably in oncology and cardiac failures, was evident. The metrics displayed AUC values ranging between 61% and 99.91%. Sensitivity metrics spanned from 12% to 96.50%, specificity from 76.30% to 98.80%, positive predictive values varied from 83.70% to 94.10%, and negative predictive values between 94.10% and 99.10%. Despite variations in specific metrics, AI models drawing on HIE data unfailingly showcased commendable predictive proficiency in clinical verdicts, emphasizing the transformative potential of melding AI with HIE. However, variations in sensitivity highlight underlying challenges. As healthcare's path becomes more enmeshed with AI, a well-rounded, enlightened approach is pivotal to guarantee the delivery of trustworthy and effective AI-augmented healthcare solutions.
Collapse
|
11
|
Identification of Sleep Patterns via Clustering of Hypnodensities. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083670 DOI: 10.1109/embc40787.2023.10340905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Sleep patterns vary widely between individuals. We explore methods for identifying populations exhibiting similar sleep patterns in an automated fashion using polysomnography data. Our novel approach applies unsupervised machine learning algorithms to hypnodensities graphs generated by a pre-trained neural network. In a population of 100 subjects we identify two stable clusters whose characteristics we visualize graphically and through estimates of total sleep time. We also find that the hypnodensity representation of the sleep stages produces more robust clustering results than the same methods applied to traditional hypnograms.
Collapse
|
12
|
Towards a Lightweight Classifier to Detect Hypovolemic Shock. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-5. [PMID: 38083358 DOI: 10.1109/embc40787.2023.10340949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Predicting the ability of an individual to compensate for blood loss during hemorrhage and detect the likely onset of hypovolemic shock is necessary to permit early clinical intervention. Towards this end, the compensatory reserve metric (CRM) has been demonstrated to directly correlate with an individual's ability to maintain compensatory mechanisms during loss of blood volume from onset (one-hundred percent health) to exsanguination (zero percent health). This effort describes a lightweight, three-class predictor (good, fair, poor) of an individual's compensatory reserve using a linear support-vector machine (SVM) classifier. A moving mean filter of the predictions demonstrates a feasible model for implementation of real-time hypovolemia monitoring on a wearable device, requiring only 408 bytes to store the models' coefficients and minimal processor cycles to complete the computations.
Collapse
|
13
|
Using AI to Detect Pain through Facial Expressions: A Review. Bioengineering (Basel) 2023; 10:bioengineering10050548. [PMID: 37237618 DOI: 10.3390/bioengineering10050548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/24/2023] [Accepted: 04/27/2023] [Indexed: 05/28/2023] Open
Abstract
Pain assessment is a complex task largely dependent on the patient's self-report. Artificial intelligence (AI) has emerged as a promising tool for automating and objectifying pain assessment through the identification of pain-related facial expressions. However, the capabilities and potential of AI in clinical settings are still largely unknown to many medical professionals. In this literature review, we present a conceptual understanding of the application of AI to detect pain through facial expressions. We provide an overview of the current state of the art as well as the technical foundations of AI/ML techniques used in pain detection. We highlight the ethical challenges and the limitations associated with the use of AI in pain detection, such as the scarcity of databases, confounding factors, and medical conditions that affect the shape and mobility of the face. The review also highlights the potential impact of AI on pain assessment in clinical practice and lays the groundwork for further study in this area.
Collapse
|
14
|
A Review of Voice-Based Pain Detection in Adults Using Artificial Intelligence. Bioengineering (Basel) 2023; 10:bioengineering10040500. [PMID: 37106687 PMCID: PMC10135816 DOI: 10.3390/bioengineering10040500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 04/13/2023] [Accepted: 04/19/2023] [Indexed: 04/29/2023] Open
Abstract
Pain is a complex and subjective experience, and traditional methods of pain assessment can be limited by factors such as self-report bias and observer variability. Voice is frequently used to evaluate pain, occasionally in conjunction with other behaviors such as facial gestures. Compared to facial emotions, there is less available evidence linking pain with voice. This literature review synthesizes the current state of research on the use of voice recognition and voice analysis for pain detection in adults, with a specific focus on the role of artificial intelligence (AI) and machine learning (ML) techniques. We describe the previous works on pain recognition using voice and highlight the different approaches to voice as a tool for pain detection, such as a human effect or biosignal. Overall, studies have shown that AI-based voice analysis can be an effective tool for pain detection in adult patients with various types of pain, including chronic and acute pain. We highlight the high accuracy of the ML-based approaches used in studies and their limitations in terms of generalizability due to factors such as the nature of the pain and patient population characteristics. However, there are still potential challenges, such as the need for large datasets and the risk of bias in training models, which warrant further research.
Collapse
|
15
|
Technical note: Improved differentiation of calcification from hemosiderin using paramagnetic- and diamagnetic-specific magnetic resonance susceptibility weighted imaging (p-SWI, d-SWI). Clin Imaging 2023; 99:47-52. [PMID: 37088060 PMCID: PMC10180168 DOI: 10.1016/j.clinimag.2023.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 04/07/2023] [Indexed: 04/25/2023]
Abstract
INTRODUCTION Differentiation of calcification and calcium-containing tissue from blood products remains challenging using magnetic resonance imaging (MRI). We developed a novel post-processing algorithm which creates both paramagnetic- and diamagnetic-specific SWI images generated from T2* weighted images using distinct "positive" and "negative" phase masks. METHODS 10 patients who had undergone clinical MRI scanning of the brain with a rapid echo planar based T2*-weighted EPI-GRE pulse sequence with evidence for either hemosiderin and/or calcifications were retrospectively identified. Complex raw k-space data from individual imaging coils were then extracted, reconstructed, and appropriately combined to produce magnitude and phase images using a phase preserving method. The final reconstructed images included the T2* EPI-GRE magnitude images, p-SWI and d-SWI images. Filtered phase images were also available for review. Correlation with CT scans and MR imaging appearance over time corroborated the composition of the voxels. RESULTS Differential "blooming" of diamagnetic and paramagnetic foci was readily identified on the corresponding p-SWI and d-SWI images and provided fast and reliable visual differentiation of diamagnetic from paramagnetic susceptibility effects by ascertaining which of the two images depicted the greatest "blooming" effect. Correlation with the available filtered phase maps was not necessary for differentiation of paramagnetic from diamagnetic image components. CONCLUSION Clinical interpretation of SWI images can be further enhanced by creating specific p-SWI and d-SWI image pairs which contain greater visual information than the combination of standard p-SWI images and phase image.
Collapse
|
16
|
Imaging evaluated remotely through telemedicine as a reliable alternative for accurate diagnosis: a systematic review. HEALTH AND TECHNOLOGY 2023. [DOI: 10.1007/s12553-023-00745-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023]
|
17
|
Perceived Age as a Mortality and Comorbidity Predictor: A Systematic Review. Aesthetic Plast Surg 2023; 47:442-454. [PMID: 35650301 DOI: 10.1007/s00266-022-02932-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 05/01/2022] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Perceived age is defined as how old a person looks to external evaluators. It reflects the underlying biological age, which is a measure based on physical and physiological parameters reflecting a person's aging process more accurately than chronological age. People with a higher biological age have shorter lives compared to those with a lower biological age with the same chronological age. Our review aims to find whether increased perceived age is a risk factor for overall mortality risk or comorbidities. METHODS A literature search of three databases was conducted following the PRISMA guidelines for studies analyzing perceived age or isolated facial characteristics of old age and their relationship to mortality risk or comorbidity outcomes. Data on the number of patients, type and characteristics of evaluation methods, evaluator characteristics, mean chronologic age, facial characteristics studied, measured outcomes, and study results were collected. RESULTS Out of 977 studies, 15 fulfilled the inclusion criteria. These studies found an increase in mortality risk of 6-51% in older-looking people compared to controls (HR 1.06-1.51, p < 0.05). In addition, perceived age and some facial characteristics of old age were also associated with cardiovascular risk and myocardial infarction, cognitive function, bone mineral density, and chronic obstructive pulmonary disease (COPD). CONCLUSION Perceived age promises to be a clinically useful predictor of overall mortality and cardiovascular, pulmonary, cognitive, and osseous comorbidities. LEVEL OF EVIDENCE III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Collapse
|
18
|
Physiological markers of sleep quality: A scoping review. Sleep Med Rev 2022; 64:101657. [PMID: 35753151 DOI: 10.1016/j.smrv.2022.101657] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 05/16/2022] [Accepted: 05/29/2022] [Indexed: 10/18/2022]
Abstract
Understanding the associations between adequate sleep, performance and health outcomes is vital, yet a major limitation in the design and interpretation of studies of sleep and performance is the variability of subjective and objective markers used to assess sleep quality. The aim of this scoping review is to investigate how various physiological signals recorded during sleep or wakefulness relate to objective measures of cognitive or physical performance and subjectively perceived sleep quality to inform conceptual understanding of the elusive, amorphous, and multi-dimensional construct of sleep quality. We also aimed to suggest priorities for future areas of research in sleep quality and performance. We searched six databases ultimately yielding 439 studies after duplicate removal. Sixty-five studies were selected for full review. In general, correlations between objectively measured sleep and objective performance or subjectively assessed sleep quality were weak to moderate. Slow wave sleep was moderately correlated with better performance on tasks of vigilance, motor speed, and executive function as well as better subjective sleep quality and feeling well-rested, suggesting that slow wave sleep may be important for sleep quality and optimal daytime performance. However, these findings were inconsistent across studies. Increased sleep fragmentation was associated with poorer subjective sleep quality in both polysomnographic and actigraphic studies. Studies which simultaneously assessed physiologic sleep measures, performance measures and subjective sleep perception were few, limiting the ability to evaluate correlations between subjective and objective outcomes concurrently in the same individuals. Factors influencing the relationship between sleep quality and performance include circadian variability, sleep inertia, and mismatch between sleep stages studied and outcome measures of choice. Ultimately, the determination of "quality sleep" remains largely subjective and inconsistently quantifiable by current measures. Methods evaluating sleep as a continuous measure rather than traditional sleep stages may provide an intriguing approach to future studies of sleep and performance. Future well-designed studies using novel measures of sleep or multimodal ambulatory wearables assessing the three domains of sleep and performance (objective sleep physiology, objective performance, and subjective sleep quality) are needed to better define quality sleep.
Collapse
|
19
|
Thigh musculature stiffness during active muscle contraction after anterior cruciate ligament injury. BMC Musculoskelet Disord 2020; 21:320. [PMID: 32438905 PMCID: PMC7243327 DOI: 10.1186/s12891-020-03342-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 05/11/2020] [Indexed: 12/31/2022] Open
Abstract
Background Altered motor unit (MU) activity has been identified after anterior cruciate ligament (ACL) injury, but its effect on muscle tissue properties is unknown. The purpose of this study was to compare thigh musculature muscle stiffness between control and ACL-injured subjects. Methods Thirty ACL-injured subjects and 25 control subjects were recruited. Subjects completed a randomized protocol of isometric contractions while electromyography (EMG) signals were recorded. Three maximum voluntary isometric contractions (MVIC) determined peak force for 10 and 25% MVIC trials. Shear wave elastography was captured during each 10 and 25% MVIC trials. Results Differences in muscle stiffness were assessed between limbs and groups. 12 months post-surgery had higher stiffness for VM 0% MVIC, VL 0 and 10% MVIC, and ST 10 and 25% MVIC (all p ≤ 0.04). Conclusion Thigh musculature stiffness changed throughout rehabilitation and remained altered at 12 months after ACL reconstruction.
Collapse
|
20
|
Real-Time Quality Assessment of Long-Term ECG Signals Recorded by Wearables in Free-Living Conditions. IEEE Trans Biomed Eng 2020; 67:2721-2734. [PMID: 31995473 DOI: 10.1109/tbme.2020.2969719] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. METHODS The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. RESULTS The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. CONCLUSION The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. SIGNIFICANCE The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.
Collapse
|
21
|
1D Convolutional Neural Networks for Estimation of Compensatory Reserve from Blood Pressure Waveforms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:2169-2173. [PMID: 31946331 DOI: 10.1109/embc.2019.8857116] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
We propose a Deep Convolutional Neural Network (CNN) architecture for computing a Compensatory Reserve Metric (CRM) for trauma victims suffering from hypovolemia (decreased circulating blood volume). The CRM is a single health indicator value that ranges from 100% for healthy individuals, down to 0% at hemodynamic decompensation - when the body can no longer compensate for blood loss. The CNN is trained on 20 second blood pressure waveform segments obtained from a finger-cuff monitor of 194 subjects. The model accurately predicts CRM when tested on data from 22 additional human subjects obtained from Lower Body Negative Pressure (LBNP) emulation of hemorrhage, attaining a mean squared error (MSE) of 0.0238 over the full range of values, including those from subjects with both low and high tolerance to central hypovolemia.
Collapse
|
22
|
Data Compression via Low Complexity Delta Transition Lossless Encoding for Remote Physiological and Environmental Monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:4379-4384. [PMID: 30441324 DOI: 10.1109/embc.2018.8513277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Continuous remote physiologic and environmental monitoring, employing an ever-increasing array of sensors, is now commonplace. Given the significant amount of data being digitized, two common sources of energy consumption can be targeted to improve device runtime: data storage and data transmission. One embedded method to maximize device runtime is inline low energy data compression. Herein we present a low complexity data encoding scheme. We list and characterize the parameters necessary for encoding. The encoding method is then evaluated and tuned using contrived data with varying degrees of covariance, as well as open-source electrocardiography (ECG) data. Finally, the encoding method is evaluated with tri-axial accelerometry and ECG data previously collected on a Mount Everest Expedition using a remote physiologic monitor that was specifically designed for long autonomous runtimes. With the described low overhead delta transition lossless encoding method, the Mt. Everest device runtime would have doubled from two to four weeks of continuous recording. Finally, this approach would be beneficial given a requirement to transmit data wirelessly in real time, since the total transmission power and energy would be reduced by an amount related to the compression ratio.
Collapse
|
23
|
Simulated imaging of atherosclerotic & radiofrequency ablation lesions using phase subtraction. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:5630-5633. [PMID: 26737569 DOI: 10.1109/embc.2015.7319669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Cardiovascular diseases are the main cause of death worldwide. Atherosclerosis and atrial fibrillation are structural and electrical pathophysiology, respectively, that can lead to acute events such as stroke or myocardial infarction. We used particle-based Monte Carlo methods to simulate X-ray phase imaging of atherosclerotic plaque types IV-VIII in the aorta, iliac, and coronary arteries. We also assessed scar lesion development in radiofrequency catheter ablation treatment of atrial fibrillation by simulating lesions 2, 5, 10, 30, and 60 days post-procedure. For both applications, we found high signal-to-noise and contrast-to-noise ratios in all lesions. These results suggest that X-ray phase imaging is a viable technique for non-invasive quantitative cardiovascular lesion characterization.
Collapse
|
24
|
Recent advances in 3D time-resolved contrast-enhanced MR angiography. J Magn Reson Imaging 2015; 42:3-22. [PMID: 26032598 DOI: 10.1002/jmri.24880] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2014] [Accepted: 12/31/2014] [Indexed: 11/11/2022] Open
Abstract
Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The purpose of this work is to describe how this has been accomplished. Specific technical enablers have been: improved gradients allowing reduced repetition times, improved k-space sampling and reconstruction methods, parallel acquisition, particularly in two directions, and improved and higher count receiver coil arrays. These have collectively made high-resolution time-resolved studies readily available for many anatomic regions. Depending on the application, ∼1 mm isotropic resolution is now possible with frame times of several seconds. Clinical applications of time-resolved CE-MRA are briefly reviewed.
Collapse
|
25
|
Prospective comparison of cartesian acquisition with projection-like reconstruction magnetic resonance angiography with computed tomography angiography for evaluation of below-the-knee runoff. J Vasc Interv Radiol 2013; 24:392-9. [PMID: 23433414 DOI: 10.1016/j.jvir.2012.11.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2012] [Revised: 11/05/2012] [Accepted: 11/08/2012] [Indexed: 11/19/2022] Open
Abstract
PURPOSE To compare prospectively the assessment of stenosis and radiologist confidence in the evaluation of below-the-knee lower extremity runoff vessels between computed tomography (CT) angiography and contrast-enhanced magnetic resonance (MR) angiography in a cohort of 19 clinical patients. MATERIALS AND METHODS The study was compliant with the Health Insurance Portability and Accountability Act of 1996 and approved by the institutional review board. Imaging was performed in 19 consecutive patients with known or suspected peripheral arterial disease; both CT angiography and a more recently developed MR angiography technique were performed within 24 hours of each other and before any therapeutic intervention. Resulting images were randomized and interpreted in blinded fashion by four board-certified radiologists with expertise in CT angiography and MR angiography. Vasculature of the lower leg was apportioned into 22 segments, 11 for each leg. For each segment, degree of stenosis and confidence of diagnosis were determined using a 3-point scale. Differences between CT angiography and MR angiography were assessed for significance using pooled histograms that were analyzed using the Wilcoxon signed rank test. RESULTS For assessment of stenosis, there was no difference in CT angiography compared with MR angiography for 20 of 22 segments. For confidence of diagnosis, assessment of popliteal arteries was superior on CT angiography compared with MR angiography (P<.05). Confidence in assessment of both tibioperoneal trunks and the left proximal anterior tibial artery was not significantly different between CT angiography and MR angiography. Confidence in assessment of all other 17 segments was superior with MR angiography compared with CT angiography (P<.02). CONCLUSIONS MR angiography using the method described here is a promising technique for evaluating lower extremity arterial runoff. MR angiography had an overall superior performance in radiologist confidence compared with CT angiography for imaging runoff vessels below the knee.
Collapse
|
26
|
High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet. J Magn Reson Imaging 2011; 34:2-12. [PMID: 21698702 DOI: 10.1002/jmri.22469] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Methods are described for generating 3D time-resolved contrast-enhanced magnetic resonance (MR) angiograms of the hands and feet. Given targeted spatial resolution and frame times, it is shown that acceleration of about one order of magnitude or more is necessary. This is obtained by a combination of 2D sensitivity encoding (SENSE) and homodyne (HD) acceleration methods. Image update times from 3.4-6.8 seconds are provided in conjunction with view sharing. Modular receiver coil arrays are described which can be designed to the targeted vascular region. Images representative of the technique are generated in the vasculature of the hands and feet in volunteers and in patient studies.
Collapse
|
27
|
Sparse-CAPR: highly accelerated 4D CE-MRA with parallel imaging and nonconvex compressive sensing. Magn Reson Med 2011; 66:1019-32. [PMID: 21608028 DOI: 10.1002/mrm.22892] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2010] [Revised: 12/10/2010] [Accepted: 01/31/2011] [Indexed: 11/11/2022]
Abstract
Cartesian Acquisition with Projection-Reconstruction-like sampling is a SENSE-type parallel 3DFT acquisition paradigm for 4D contrast-enhanced magnetic resonance angiography that has been demonstrated capable of providing high spatial and temporal resolution, diagnostic-quality images at very high acceleration rates. However, Cartesian Acquisition with Projection-Reconstruction-like sampling images are typically reconstructed online using Tikhonov regularization and partial Fourier methods, which are prone to exhibit noise amplification and undersampling artifacts when operating at very high acceleration rates. In this work, a sparsity-driven offline reconstruction framework for Cartesian Acquisition with Projection-Reconstruction-like sampling is developed and demonstrated to consistently provide improvements over the currently-employed reconstruction strategy against these ill-effects. Moreover, the proposed reconstruction strategy requires no changes to the existing Cartesian Acquisition with Projection-Reconstruction-like sampling acquisition protocol, and an efficient numerical optimization and hardware system are described that allow for a 256 × 160 × 80 volume contrast-enhanced magnetic resonance angiography volume to be reconstructed from an eight-channel data set in less than 2 min.
Collapse
|
28
|
High-performance 3D compressive sensing MRI reconstruction. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2011; 2010:3321-4. [PMID: 21096822 DOI: 10.1109/iembs.2010.5627493] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Compressive Sensing (CS) is a nascent sampling and reconstruction paradigm that describes how sparse or compressible signals can be accurately approximated using many fewer samples than traditionally believed. In magnetic resonance imaging (MRI), where scan duration is directly proportional to the number of acquired samples, CS has the potential to dramatically decrease scan time. However, the computationally expensive nature of CS reconstructions has so far precluded their use in routine clinical practice - instead, more-easily generated but lower-quality images continue to be used. We investigate the development and optimization of a proven inexact quasi-Newton CS reconstruction algorithm on several modern parallel architectures, including CPUs, GPUs, and Intel's Many Integrated Core (MIC) architecture. Our (optimized) baseline implementation on a quad-core Core i7 is able to reconstruct a 256 × 160×80 volume of the neurovasculature from an 8-channel, 10 × undersampled data set within 56 seconds, which is already a significant improvement over existing implementations. The latest six-core Core i7 reduces the reconstruction time further to 32 seconds. Moreover, we show that the CS algorithm benefits from modern throughput-oriented architectures. Specifically, our CUDA-base implementation on NVIDIA GTX480 reconstructs the same dataset in 16 seconds, while Intel's Knights Ferry (KNF) of the MIC architecture even reduces the time to 12 seconds. Such level of performance allows the neurovascular dataset to be reconstructed within a clinically viable time.
Collapse
|
29
|
Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds. Magn Reson Med 2011; 64:1171-81. [PMID: 20715291 DOI: 10.1002/mrm.22434] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.
Collapse
|
30
|
Time-resolved bolus-chase MR angiography with real-time triggering of table motion. Magn Reson Med 2011; 64:629-37. [PMID: 20597121 DOI: 10.1002/mrm.22537] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Time-resolved bolus-chase contrast-enhanced MR angiography with real-time station switching is demonstrated. The Cartesian acquisition with projection reconstruction-like sampling (CAPR) technique and high 2D sensitivity encoding (SENSE) (6x or 8x) and 2D homodyne (1.8x) accelerations were used to acquire 3D volumes with 1.0-mm isotropic spatial resolution and frame times as low as 2.5 sec in two imaging stations covering the thighs and calves. A custom real-time system was developed to reconstruct and display CAPR frames for visually guided triggering of table motion upon passage of contrast through the proximal station. The method was evaluated in seven volunteers. High-spatial-resolution arteriograms with minimal venous contamination were consistently acquired in both stations. Real-time stepping table contrast-enhanced MR angiography is a method for providing time-resolved images with high spatial resolution over an extended field-of-view.
Collapse
|
31
|
High spatial and temporal resolution imaging of the arterial vasculature of the lower extremity with contrast enhanced MR angiography. Clin Anat 2011; 24:478-88. [PMID: 21509813 DOI: 10.1002/ca.21124] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2010] [Revised: 11/17/2010] [Accepted: 11/29/2010] [Indexed: 11/11/2022]
Abstract
Vascular imaging can be essential in the diagnosis, monitoring, and planning and assessment of treatment of patients with peripheral vascular disease. The purpose of this work is to describe a recently developed three-dimensional (3D) time-resolved contrast-enhanced MR angiography (CE-MRA) technique, Cartesian Acquisition with Projection Reconstruction-like sampling (CAPR), and its application to imaging of the vasculature of the lower legs and feet. CAPR implements accelerated imaging techniques and uses specialized multielement imaging coil arrays to achieve high temporal and high spatial resolution imaging. Volunteer and patient studies of the vasculature of the lower legs and feet have been performed. Temporal resolution of 4.9-6.5 sec and spatial resolution less than or equal to 1 mm in all directions allow for the depiction of progressive arterial filling and complex flow patterns as well as sharp visualization of vascular structure as small as the fine muscular branches. High-quality diagnostic imaging is made possible with CAPR's advanced acquisition and reconstruction techniques and the use of specialized coil arrays.
Collapse
|
32
|
Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography. Radiology 2009; 253:831-43. [PMID: 19789238 DOI: 10.1148/radiol.2533081744] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction-like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE). MATERIALS AND METHODS All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27-53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography. RESULTS The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations. CONCLUSION The feasibility of performing high-diagnostic-quality time-resolved 3D contrast-enhanced MR angiography of the peripheral vasculature by using CAPR and eightfold accelerated 2D SENSE has been demonstrated.
Collapse
|
33
|
Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography. Radiology 2009; 253:532-42. [PMID: 19789236 DOI: 10.1148/radiol.2532082322] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This study was HIPAA compliant and institutional review board approved, and informed consent was obtained from all volunteers. The authors describe a method for generating a time-of-arrival (TOA) map of intravenously administered contrast material, as observed in a time series of three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiograms. The method may enable visualization and interpretation, on one 3D image, of the temporal enhancement patterns that occur in the vasculature. Colorization of TOA values may further aid interpretation. The quality of the results depends not only on the adequacy of the frame rate, spatial resolution, and signal-to-noise ratio of the MR image acquisition method but also on the accuracy and clarity with which the leading edge of the contrast material bolus is depicted. The criteria for optimizing these parameters are described. The TOA mapping technique is demonstrated by using vascular studies of the hands, brain, and lower leg regions.
Collapse
|
34
|
Controlled experimental study depicting moving objects in view-shared time-resolved 3D MRA. Magn Reson Med 2009; 62:85-95. [PMID: 19319897 DOI: 10.1002/mrm.21993] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Various methods have been used for time-resolved contrast-enhanced magnetic resonance angiography (CE-MRA), many involving view sharing. However, the extent to which the resultant image time series represents the actual dynamic behavior of the contrast bolus is not always clear. Although numerical simulations can be used to estimate performance, an experimental study can allow more realistic characterization. The purpose of this work was to use a computer-controlled motion phantom for study of the temporal fidelity of three-dimensional (3D) time-resolved sequences in depicting a contrast bolus. It is hypothesized that the view order of the acquisition and the selection of views in the reconstruction can affect the positional accuracy and sharpness of the leading edge of the bolus and artifactual signal preceding the edge. Phantom studies were performed using dilute gadolinium-filled vials that were moved along tabletop tracks by a computer-controlled motor. Several view orders were tested using view-sharing and Cartesian sampling. Compactness of measuring the k-space center, consistency of view ordering within each reconstruction frame, and sampling the k-space center near the end of the temporal footprint were shown to be important in accurate portrayal of the leading edge of the bolus. A number of findings were confirmed in an in vivo CE-MRA study.
Collapse
|
35
|
3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain. Magn Reson Med 2009; 60:749-60. [PMID: 18727101 DOI: 10.1002/mrm.21675] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Sensitivity encoding (SENSE) and partial Fourier techniques have been shown to reduce the acquisition time and provide high diagnostic quality images. However, for time-resolved acquisitions there is a need for both high temporal and spatial resolution. View sharing can be used to provide an increased frame rate but at the cost of acquiring spatial frequencies over a duration longer than a frame time. In this work we hypothesize that a CArtesian Projection Reconstruction-like (CAPR) technique in combination with 2D SENSE, partial Fourier, and view sharing can provide 1-2 mm isotropic resolution with sufficient temporal resolution to distinguish intracranial arterial and venous phases of contrast passage in whole-brain angiography. In doing so, the parameter of "temporal footprint" is introduced as a descriptor for characterizing and comparing time-resolved view-shared pulse sequences. It is further hypothesized that short temporal footprint sequences have higher temporal fidelity than similar sequences with longer temporal footprints. The tradeoff of temporal footprint and temporal acceleration is presented and characterized in numerical simulations. Results from 11 whole-brain contrast-enhanced MR angiography studies with the new method with SENSE acceleration factors R = 4 and 5.3 are shown to provide images of comparable or higher diagnostic quality than the unaccelerated reference.
Collapse
|
36
|
Cartesian Acquisition with PR-Like Sampling (CAPR). ROFO-FORTSCHR RONTG 2009. [DOI: 10.1055/s-0028-1124048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
37
|
Intracranial contrast-enhanced magnetic resonance venography with 6.4-fold sensitivity encoding at 1.5 and 3.0 Tesla. J Magn Reson Imaging 2008; 27:653-8. [PMID: 18224674 DOI: 10.1002/jmri.21255] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To prospectively compare vessel conspicuity and diagnostic image quality between three-dimensional intracranial contrast-enhanced MR venography acquired at 1.5 Tesla (T) and 3.0T, with 6.4-fold sensitivity encoding. MATERIALS AND METHODS Ten healthy volunteers were imaged on 1.5T and 3.0T MR scanners using eight-element head coil arrays. The intracranial venous vasculature was divided into five groups for evaluation based on vessel size and anatomical location. Two radiologists independently assessed vessel conspicuity, level of artifacts, and diagnostic image quality. Informed consent was obtained, and the study was approved by the institutional review board. RESULTS With the exception of large cerebral sinuses where 1.5T and 3.0T results were rated as equivalent, 3.0T images demonstrated superior vessel continuity, sharpness, and signal contrast to background tissue than 1.5T for all other intracranial venous vasculature (P < 0.01). No statistical significance in overall image quality was found between 1.5T and 3.0T venograms, and all data sets were deemed sufficient for diagnostic interpretation. CONCLUSION Whole brain contrast-enhanced venography with 6.4-fold sensitivity encoding is robust and has the potential to become the method of choice for fast visualization of the intracranial venous vasculature. At 3.0T, demonstration of small cerebral vessels is superior to 1.5T.
Collapse
|
38
|
Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV. Magn Reson Med 2008; 58:855-64. [PMID: 17969124 DOI: 10.1002/mrm.21282] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The relative signal-to-noise ratio (SNR) provided by 2D sensitivity encoding (SENSE) when applied to 3D contrast-enhanced MR angiography (CE-MRA) is studied. If an elliptical centric phase-encoding order is used to map the waning magnetization of the contrast bolus to k-space, the application of SENSE will reduce the degree of k-space signal modulation, providing a signal amplification A over corresponding nonaccelerated acquisitions. This offsets the SNR loss in R-accelerated SENSE due to suquare root R and the geometry (g) factor. The theoretical bound on A is R and is reduced from this depending on the properties of the bolus profile and the duration over which it is imaged. In this work a signal amplification of 1.14-1.23 times that of nonvascular background tissue is demonstrated in a study of 20 volunteers using R = 4 2D SENSE whole-brain MR venography (MRV). The effects of a nonuniform g-factor and inhomogeneity of background tissue are accounted for. The observed amplification compares favorably with the value of 1.31 predicted numerically from a measured bolus curve.
Collapse
|
39
|
High-spatial-resolution contrast-enhanced MR angiography of the intracranial venous system with fourfold accelerated two-dimensional sensitivity encoding. Radiology 2007; 243:853-61. [PMID: 17446523 PMCID: PMC2813572 DOI: 10.1148/radiol.2433060819] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Informed consent was obtained; the study was HIPAA compliant and institutional review board approved. Fourfold accelerated (FFA) two-dimensional (2D) sensitivity encoding (SENSE) (65 seconds) was prospectively compared with its nonaccelerated counterpart (4 minutes 20 seconds) for diagnostic image quality and sharpness of visualization of blood vessels at 1.5 T with three-dimensional (3D) intracranial contrast-enhanced magnetic resonance venography in 18 consecutive volunteers (10 men, eight women; mean age, 48.4 years) and two patients (55-year-old man, 30-year-old woman). Two readers compared FFA 2D SENSE results with results from its nonaccelerated counterpart; they rated visualization of large and medium sinuses as equivalent (P>.1) and that of small deep cerebral veins (P<.01) and superficial cerebral veins (P<.001) as superior. Overall diagnostic image quality ratings were excellent for 62% and 80% of nonaccelerated and FFA 2D SENSE results, respectively (P<.05). FFA 2D SENSE may become the method of choice for fast visualization of intracranial venous vasculature in clinical practice.
Collapse
|
40
|
Quantitative characterization of lung disease. Comput Med Imaging Graph 2005; 29:555-63. [PMID: 16143495 DOI: 10.1016/j.compmedimag.2005.04.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2005] [Revised: 04/11/2005] [Accepted: 04/11/2005] [Indexed: 11/16/2022]
Abstract
The increase in prevalence, incidence and variety of pulmonary diseases has precipitated the need for more non-invasive quantitative assessment of structure/function relationships in the lung. This need requires concise description not only of lung anatomy but also of associated underlying mechanics of pulmonary function, as well as deviation from normal in specific diseases. This can be facilitated through the use of adaptive deformable surface models of the lung at end inspiratory and expiratory volumes. Lung surface deformation may be used to represent tissue excursion, which can characterize both global and regional lung mechanics. In this paper, we report a method for robust determination and visualization of pulmonary structure and function using clinical CT scans. The method provides both intuitive 3D parametric visualization and objective quantitative assessment of lung structure and associated function, in both normal and pathological cases.
Collapse
|
41
|
Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography. Magn Reson Med 2005; 55:50-8. [PMID: 16315207 DOI: 10.1002/mrm.20726] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Although contrast-enhanced MR angiography (CE-MRA) has been successfully developed into a routine clinical imaging technique, there is still need for improved spatial resolution in a given acquisition time. Undersampled projection reconstruction (PR) techniques maintain spatial resolution with reduced scan times, and the elliptical centric (EC) view order provides high quality arterial phase images without venous contamination. In this work, we present a hybrid elliptical centric-projection reconstruction (EC-PR) technique to provide spatial resolution improvement over standard EC in a given time. The k-space sampling was performed by undersampling the periphery of the k(Y)-k(Z) phase encoding plane of an EC view order in a PR like manner. The sampled views were maintained on a rectilinear grid, and thus reconstructed by standard 3DFT. The non-sampled views were compensated either by zero-filling or performing a 2D homodyne reconstruction. Compared to a fully sampled k-space, the EC-PR sequence acquired in the same scan time provides a resolution improvement of about two, as shown by point spread function analysis and phantom experiments. The hypothesis that EC-PR provides improved resolution while retaining diagnostically adequate SNR was tested in 11 CE-MRA studies of the popliteal and carotid arteries and shown to be true (P < 0.03).
Collapse
|