1
|
Revealing speckle obscured living human retinal cells with artificial intelligence assisted adaptive optics optical coherence tomography. COMMUNICATIONS MEDICINE 2024; 4:68. [PMID: 38600290 PMCID: PMC11006674 DOI: 10.1038/s43856-024-00483-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 03/13/2024] [Indexed: 04/12/2024] Open
Abstract
BACKGROUND In vivo imaging of the human retina using adaptive optics optical coherence tomography (AO-OCT) has transformed medical imaging by enabling visualization of 3D retinal structures at cellular-scale resolution, including the retinal pigment epithelial (RPE) cells, which are essential for maintaining visual function. However, because noise inherent to the imaging process (e.g., speckle) makes it difficult to visualize RPE cells from a single volume acquisition, a large number of 3D volumes are typically averaged to improve contrast, substantially increasing the acquisition duration and reducing the overall imaging throughput. METHODS Here, we introduce parallel discriminator generative adversarial network (P-GAN), an artificial intelligence (AI) method designed to recover speckle-obscured cellular features from a single AO-OCT volume, circumventing the need for acquiring a large number of volumes for averaging. The combination of two parallel discriminators in P-GAN provides additional feedback to the generator to more faithfully recover both local and global cellular structures. Imaging data from 8 eyes of 7 participants were used in this study. RESULTS We show that P-GAN not only improves RPE cell contrast by 3.5-fold, but also improves the end-to-end time required to visualize RPE cells by 99-fold, thereby enabling large-scale imaging of cells in the living human eye. RPE cell spacing measured across a large set of AI recovered images from 3 participants were in agreement with expected normative ranges. CONCLUSIONS The results demonstrate the potential of AI assisted imaging in overcoming a key limitation of RPE imaging and making it more accessible in a routine clinical setting.
Collapse
|
2
|
Cellular-Level Visualization of Retinal Pathology in Multiple Sclerosis With Adaptive Optics. Invest Ophthalmol Vis Sci 2023; 64:21. [PMID: 37971733 PMCID: PMC10664728 DOI: 10.1167/iovs.64.14.21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 10/09/2023] [Indexed: 11/19/2023] Open
Abstract
Purpose To apply adaptive optics-optical coherence tomography (AO-OCT) to quantify multiple sclerosis (MS)-induced changes in axonal bundles in the macular nerve fiber layer, ganglion cell somas, and macrophage-like cells at the vitreomacular interface. Methods We used AO-OCT imaging in a pilot study of MS participants (n = 10), including those without and with a history of optic neuritis (ON, n = 4), and healthy volunteers (HV, n = 9) to reveal pathologic changes to inner retinal cells and structures affected by MS. Results We found that nerve fiber layer axonal bundles had 38% lower volume in MS participants (1.5 × 10-3 mm3) compared to HVs (2.4 × 10-3 mm3; P < 0.001). Retinal ganglion cell (RGC) density was 51% lower in MS participants (12.3 cells/mm2 × 1000) compared to HVs (25.0 cells/mm2 × 1000; P < 0.001). Spatial differences across the macula were observed in RGC density. RGC diameter was 15% higher in MS participants (11.7 µm) compared to HVs (10.1 µm; P < 0.001). A nonsignificant trend of higher density of macrophage-like cells in MS eyes was also observed. For all AO-OCT measures, outcomes were worse for MS participants with a history of ON compared to MS participants without a history of ON. AO-OCT measures were associated with key visual and physical disabilities in the MS cohort. Conclusions Our findings demonstrate the utility of AO-OCT for highly sensitive and specific detection of neurodegenerative changes in MS. Moreover, the results shed light on the mechanisms that underpin specific neuronal pathology that occurs when MS attacks the retina. The new findings support the further development of AO-based biomarkers for MS.
Collapse
|
3
|
Introduction to the Feature Issue on Adaptive Optics for Biomedical Applications. BIOMEDICAL OPTICS EXPRESS 2023; 14:1772-1776. [PMID: 37078031 PMCID: PMC10110319 DOI: 10.1364/boe.488044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Indexed: 05/03/2023]
Abstract
The guest editors introduce a feature issue commemorating the 25th anniversary of adaptive optics in biomedical research.
Collapse
|
4
|
Development of polarization-sensitive optical coherence tomography imaging platform and metrics to quantify electrostimulation-induced peripheral nerve injury in vivo in a small animal model. NEUROPHOTONICS 2023; 10:025004. [PMID: 37077218 PMCID: PMC10109528 DOI: 10.1117/1.nph.10.2.025004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 03/28/2023] [Indexed: 05/03/2023]
Abstract
Significance Neuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions. Aim We aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation. Approach A sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k -values in experimental groups: sham control (SC, n = 5 , 0.0 mA / 0 Hz ), stimulation level 1 (SL1, n = 5 , 3.4 mA / 50 Hz , and k = 2.57 ), and stimulation level 2 (SL2, n = 5 , 6.8 mA / 100 Hz , and k = 3.17 ). Results The stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of + 4 % / - 309 % (SL1/SL2) in phase retardation and - 79 % / - 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a + 1 % / - 36 % difference in myelin pixel counts and - 13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of + 20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis. Conclusions The poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.
Collapse
|
5
|
Deep learning-enabled volumetric cone photoreceptor segmentation in adaptive optics optical coherence tomography images of normal and diseased eyes. BIOMEDICAL OPTICS EXPRESS 2023; 14:815-833. [PMID: 36874491 PMCID: PMC9979662 DOI: 10.1364/boe.478693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 06/11/2023]
Abstract
Objective quantification of photoreceptor cell morphology, such as cell diameter and outer segment length, is crucial for early, accurate, and sensitive diagnosis and prognosis of retinal neurodegenerative diseases. Adaptive optics optical coherence tomography (AO-OCT) provides three-dimensional (3-D) visualization of photoreceptor cells in the living human eye. The current gold standard for extracting cell morphology from AO-OCT images involves the tedious process of 2-D manual marking. To automate this process and extend to 3-D analysis of the volumetric data, we propose a comprehensive deep learning framework to segment individual cone cells in AO-OCT scans. Our automated method achieved human-level performance in assessing cone photoreceptors of healthy and diseased participants captured with three different AO-OCT systems representing two different types of point scanning OCT: spectral domain and swept source.
Collapse
|
6
|
Improved in vivo optical coherence tomography imaging of animal peripheral nerves using a prism nerve holder. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:026002. [PMID: 36785561 PMCID: PMC9921515 DOI: 10.1117/1.jbo.28.2.026002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 01/20/2023] [Indexed: 06/01/2023]
Abstract
Significance Modern optical volumetric imaging modalities, such as optical coherence tomography (OCT), provide enormous information about the structure, function, and physiology of living tissue. Although optical imaging achieves lateral resolution on the order of the wavelength of light used, and OCT achieves axial resolution on a similar micron scale, tissue optical properties, particularly high scattering and absorption, limit light penetration to only a few millimeters. In addition, in vivo imaging modalities are susceptible to significant motion artifacts due to cardiac and respiratory function. These effects limit access to artifact-free optical measurements during peripheral neurosurgery to only a portion of the exposed nerve without further modification to the procedure. Aim We aim to improve in vivo OCT imaging during peripheral neurosurgery in small and large animals by increasing the amount of visualized nerve volume as well as suppressing motion of the imaged area. Approach We designed a nerve holder with embedded mirror prisms for peripheral nerve volumetric imaging as well as a specific beam steering strategy to acquire prism and direct view volumes in one session with minimal motion artifacts. Results The axially imaged volumes from mirror prisms increased the OCT signal intensity by > 22 dB over a 1.25-mm imaging depth in tissue-mimicking phantoms. We then demonstrated the new imaging capabilities in visualizing peripheral nerves from direct and side views in living rats and minipigs using a polarization-sensitive OCT system. Prism views have shown nerve fascicles and vasculature from the bottom half of the imaged nerve which was not visible in direct view. Conclusions We demonstrated improved OCT imaging during neurosurgery in small and large animals by combining the use of a prism nerve holder with a specifically designed beam scanning protocol. Our strategy can be applied to existing OCT imaging systems with minimal hardware modification, increasing the nerve tissue volume visualized. Enhanced imaging depth techniques may lead to a greater adoption of structural and functional optical biomarkers in preclinical and clinical medicine.
Collapse
|
7
|
Ultrahigh-speed multimodal adaptive optics system for microscopic structural and functional imaging of the human retina. BIOMEDICAL OPTICS EXPRESS 2022; 13:5860-5878. [PMID: 36733751 PMCID: PMC9872887 DOI: 10.1364/boe.462594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 09/16/2022] [Accepted: 09/20/2022] [Indexed: 05/02/2023]
Abstract
We describe the design and performance of a multimodal and multifunctional adaptive optics (AO) system that combines scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) for simultaneous retinal imaging at 13.4 Hz. The high-speed AO-OCT channel uses a 3.4 MHz Fourier-domain mode-locked (FDML) swept source. The system achieves exquisite resolution and sensitivity for pan-macular and transretinal visualization of retinal cells and structures while providing a functional assessment of the cone photoreceptors. The ultra-high speed also enables wide-field scans for clinical usability and angiography for vascular visualization. The FDA FDML-AO system is a powerful platform for studying various retinal and neurological diseases for vision science research, retina physiology investigation, and biomarker development.
Collapse
|
8
|
Cell - Vessel Mismatch in Glaucoma: Correlation of Ganglion Cell Layer Soma and Capillary Densities. Invest Ophthalmol Vis Sci 2021; 62:2. [PMID: 34605879 PMCID: PMC8496408 DOI: 10.1167/iovs.62.13.2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 08/27/2021] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to characterize the relationship between retinal ganglion cell layer (GCL) soma density and capillary density in glaucomatous eyes. Methods Six glaucoma subjects with known hemifield defects and 6 age-matched controls were imaged with adaptive optics - optical coherence tomography (AO-OCT) at 6 locations: 3 degrees, 6 degrees, and 12 degrees temporal to the fovea above and below the midline. GCL soma density and capillary density were measured at each location. Coefficients of determination (pseudo R2) and slopes between GCL soma and capillary density were determined from mixed-effects regressions and were compared between glaucoma and control subjects, between more and less affected hemifield in subjects with glaucoma, and between subjects with early and moderate glaucoma, both in a local, bivariate model and then a global, multivariable model controlling for eccentricity and soma size. Results The global correlation between GCL soma and capillary density was stronger in control versus subjects with glaucoma (R2 = 0.59 vs. 0.22), less versus more affected hemifields (R2 = 0.55 vs. 0.01), and subjects with early versus moderate glaucoma subjects (R2 = 0.44 vs. 0.18). When controlling for eccentricity and soma size, we noted an inverse soma-capillary density local relationship in subjects with glaucoma (-388 ± 190 cells/mm2 per 1% change in capillary density, P = 0.046) and more affected hemifields (-602 ± 257 cells/mm2 per 1% change in capillary density, P = 0.03). Conclusions An inverted soma-capillary density local relationship in areas affected by glaucoma potentially explains weaker global correlations observed between GCL soma and capillary density, suggesting cell-vessel mismatch is associated with the disease.
Collapse
|
9
|
Weakly supervised individual ganglion cell segmentation from adaptive optics OCT images for glaucomatous damage assessment. OPTICA 2021; 8:642-651. [PMID: 35174258 PMCID: PMC8846574 DOI: 10.1364/optica.418274] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Cell-level quantitative features of retinal ganglion cells (GCs) are potentially important biomarkers for improved diagnosis and treatment monitoring of neurodegenerative diseases such as glaucoma, Parkinson's disease, and Alzheimer's disease. Yet, due to limited resolution, individual GCs cannot be visualized by commonly used ophthalmic imaging systems, including optical coherence tomography (OCT), and assessment is limited to gross layer thickness analysis. Adaptive optics OCT (AO-OCT) enables in vivo imaging of individual retinal GCs. We present an automated segmentation of GC layer (GCL) somas from AO-OCT volumes based on weakly supervised deep learning (named WeakGCSeg), which effectively utilizes weak annotations in the training process. Experimental results show that WeakGCSeg is on par with or superior to human experts and is superior to other state-of-the-art networks. The automated quantitative features of individual GCLs show an increase in structure-function correlation in glaucoma subjects compared to using thickness measures from OCT images. Our results suggest that by automatic quantification of GC morphology, WeakGCSeg can potentially alleviate a major bottleneck in using AO-OCT for vision research.
Collapse
|
10
|
A Novel Fiber-Optic Confocal Laser Caliper Approach for Non-Contact Optical Characterization of Silk Fibroin Thin Films Created by Riboflavin Photo-Crosslinking. CONFERENCE ON LASERS AND ELECTRO-OPTICS : (CLEO). CONFERENCE ON LASERS AND ELECTRO-OPTICS 2021; 2021:AF2Q.3. [PMID: 38261806 PMCID: PMC10782605 DOI: 10.1364/cleo_at.2021.af2q.3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
Silk fibroin with its attractive combination of advanced properties is promising for regenerative treatments of corneal disorders. Novel photonics approach is used to characterize the thickness and refractive index of silk fibroin thin films photo-crosslinked with a natural photosensitizer Riboflavin.
Collapse
|
11
|
Development, Validation, and Innovation in Ophthalmic Laser-Based Imaging: Report From a US Food and Drug Administration-Cosponsored Forum. JAMA Ophthalmol 2021; 139:113-118. [PMID: 33211074 DOI: 10.1001/jamaophthalmol.2020.4994] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
In April 2019, the US Food and Drug Administration, in conjunction with 11 professional ophthalmic, vision science, and optometric societies, convened a forum on laser-based imaging. The forum brought together the Food and Drug Administration, clinicians, researchers, industry members, and other stakeholders to stimulate innovation and ensure that patients in the US are the first in the world to have access to high-quality, safe, and effective medical devices. This conference focused on the technology, clinical applications, regulatory issues, and reimbursement issues surrounding innovative ocular imaging modalities. Furthermore, the emerging role of artificial intelligence in ophthalmic imaging was reviewed. This article summarizes the presentations, discussion, and future directions.
Collapse
|
12
|
Dissecting the microvascular contributions to diffuse correlation spectroscopy measurements of cerebral hemodynamics using optical coherence tomography angiography. NEUROPHOTONICS 2021; 8:025006. [PMID: 33912621 PMCID: PMC8071783 DOI: 10.1117/1.nph.8.2.025006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 03/19/2021] [Indexed: 06/12/2023]
Abstract
Significance: Diffuse correlation spectroscopy (DCS) is an emerging noninvasive, diffuse optical modality that purportedly enables direct measurements of microvasculature blood flow. Functional optical coherence tomography angiography (OCT-A) can resolve blood flow in vessels as fine as capillaries and thus has the capability to validate key attributes of the DCS signal. Aim: To characterize activity in cortical vasculature within the spatial volume that is probed by DCS and to identify populations of blood vessels that are most representative of the DCS signals. Approach: We performed simultaneous measurements of somatosensory-evoked cerebral blood flow in mice in vivo using both DCS and OCT-A. Results: We resolved sensory-evoked blood flow in the somatosensory cortex with both modalities. Vessels with diameters smaller than 10 μ m featured higher peak flow rates during the initial poststimulus positive increase in flow, whereas larger vessels exhibited considerably larger magnitude of the subsequent undershoot. The simultaneously recorded DCS waveforms correlated most highly with flow in the smallest vessels, yet featured a more prominent undershoot. Conclusions: Our direct, multiscale, multimodal cross-validation measurements of functional blood flow support the assertion that the DCS signal preferentially represents flow in microvasculature. The significantly greater undershoot in DCS, however, suggests a more spatially complex relationship to flow in cortical vasculature during functional activation.
Collapse
|
13
|
Persistent Dark Cones in Oligocone Trichromacy Revealed by Multimodal Adaptive Optics Ophthalmoscopy. Front Aging Neurosci 2021; 13:629214. [PMID: 33767618 PMCID: PMC7985087 DOI: 10.3389/fnagi.2021.629214] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 02/09/2021] [Indexed: 11/13/2022] Open
Abstract
Dark cone photoreceptors, defined as those with diminished or absent reflectivity when observed with adaptive optics (AO) ophthalmoscopy, are increasingly reported in retinal disorders. However, their structural and functional impact remain unclear. Here, we report a 3-year longitudinal study on a patient with oligocone trichromacy (OT) who presented with persistent, widespread dark cones within and near the macula. Diminished electroretinogram (ERG) cone but normal ERG rod responses together with normal color vision confirmed the OT diagnosis. In addition, the patient had normal to near normal visual acuity and retinal sensitivity. Occasional dark gaps in the photoreceptor layer were observed on optical coherence tomography, in agreement with reflectance AO scanning light ophthalmoscopy, which revealed that over 50% of the cones in the fovea were dark, increasing to 74% at 10° eccentricity. In addition, the cone density was 78% lower than normal histologic value at the fovea, and 20-40% lower at eccentricities of 5-15°. Interestingly, color vision testing was near normal at locations where cones were predominantly dark. These findings illustrate how a retina with predominant dark cones that persist over at least 3 years can support near normal central retinal function. Furthermore, this study adds to the growing evidence that cones can continue to survive under non-ideal conditions.
Collapse
|
14
|
Abstract
Purpose To characterize retinal ganglion cell morphological changes in patients with primary open-angle glaucoma associated with hemifield defect (HD) using adaptive optics–optical coherence tomography (AO-OCT). Methods Six patients with early to moderate primary open-angle glaucoma with an average age of 58 years associated with HD and six age-matched healthy controls with an average age of 61 years were included. All participants underwent in vivo retinal ganglion cell (RGC) imaging at six primary locations across the macula with AO-OCT. Ganglion cell layer (GCL) somas were manually counted, and morphological parameters of GCL soma density, size, and symmetry were calculated. RGC cellular characteristics were correlated with functional visual field measurements. Results GCL soma density was 12,799 ± 7747 cells/mm2, 9370 ± 5572 cells/mm2, and 2134 ± 1494 cells/mm2 at 3°, 6°, and 12°, respectively, in glaucoma patients compared with 25,058 ± 4649 cells/mm2, 15,551 ± 2301 cells/mm2, and 3891 ± 1105 cells/mm2 (P < 0.05 for all locations) at the corresponding retinal locations in healthy participants. Mean soma diameter was significantly larger in glaucoma patients (14.20 ± 2.30 µm) compared with the health controls (12.32 ± 1.94 µm, P < 0.05 for all locations); symmetry was 0.36 ± 0.32 and 0.86 ± 0.13 in glaucoma and control cohorts, respectively. Conclusions Glaucoma patients had lower GCL soma density and symmetry, greater soma size, and increased variation of GCL soma reflectance compared with age-matched control subjects. The morphological changes corresponded with HD, and the cellular level structural loss correlated with visual function loss in glaucoma. AO-based morphological parameters could be potential sensitive biomarkers for glaucoma.
Collapse
|
15
|
Integrating adaptive optics-SLO and OCT for multimodal visualization of the human retinal pigment epithelial mosaic. BIOMEDICAL OPTICS EXPRESS 2021; 12:1449-1466. [PMID: 33796365 PMCID: PMC7984802 DOI: 10.1364/boe.413438] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 01/29/2021] [Accepted: 01/31/2021] [Indexed: 05/03/2023]
Abstract
In vivo imaging of human retinal pigment epithelial (RPE) cells has been demonstrated through multiple adaptive optics (AO)-based modalities. However, whether consistent and complete information regarding the cellular structure of the RPE mosaic is obtained across these modalities remains uncertain due to limited comparisons performed in the same eye. Here, an imaging platform combining multimodal AO-scanning light ophthalmoscopy (AO-SLO) with AO-optical coherence tomography (AO-OCT) is developed to make a side-by-side comparison of the same RPE cells imaged across four modalities: AO-darkfield, AO-enhanced indocyanine green (AO-ICG), AO-infrared autofluorescence (AO-IRAF), and AO-OCT. Co-registered images were acquired in five subjects, including one patient with choroideremia. Multimodal imaging provided multiple perspectives of the RPE mosaic that were used to explore variations in RPE cell contrast in a subject-, location-, and even cell-dependent manner. Estimated cell-to-cell spacing and density were found to be consistent both across modalities and with normative data. Multimodal images from a patient with choroideremia illustrate the benefit of using multiple modalities to infer the cellular structure of the RPE mosaic in an affected eye, in which disruptions to the RPE mosaic may locally alter the signal strength, visibility of individual RPE cells, or even source of contrast in unpredictable ways.
Collapse
|
16
|
On the axial location of Gunn's dots. Am J Ophthalmol Case Rep 2020; 19:100757. [PMID: 32551400 PMCID: PMC7287238 DOI: 10.1016/j.ajoc.2020.100757] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 05/13/2020] [Accepted: 05/24/2020] [Indexed: 11/28/2022] Open
Abstract
Purpose To determine the axial location of Gunn's dots in the retina. Methods Adaptive optics scanning laser ophthalmoscopy (AOSLO) images and adaptive optics - optical coherence tomography (AO-OCT) volumes were collected from a region where Gunn's dots were found inferior to the optic disc from a subject determined by clinical examination to be a glaucoma suspect. AO-OCT volumes were also collected along the horizontal and vertical meridians from six healthy subjects and one glaucoma subject to identify and document other occurrences of Gunn's dots. AO-OCT volumes were registered in three-dimensions and averaged. Gunn's dots were segmented, and their volume, area, and diameter were measured. Results All Gunn's dots imaged in this study from all subjects were confined to the inner limiting membrane, neither extending into the vitreous nor into the nerve fiber layer. The size of the dots was highly variable. The measured volume, area, and diameter (mean ± standard deviation) were 1119.9 ± 590.9 μm3, 220.2 ± 105.5 μm2, and 14.3 ± 3.1 μm, the latter within the range as previously published reports. Conclusions Based upon evidence from this study and others, Gunn's dots are not thought to be Müller cell end-feet or hyalocytes. We hypothesize that they are related to microglia, either as the by-product of their phagocytosis function, or are actual dead ameboid-shaped microglia who have fulfilled their scavenger role in retinal pathology. Further studies are needed in diseased eyes to determine if they have predictive value.
Collapse
|
17
|
Longitudinal neural and vascular structural dynamics produced by chronic microelectrode implantation. Biomaterials 2020; 238:119831. [PMID: 32045783 DOI: 10.1016/j.biomaterials.2020.119831] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Revised: 01/06/2020] [Accepted: 01/25/2020] [Indexed: 12/16/2022]
Abstract
Implanted microelectrode arrays sense local neuronal activity, signals which are used as control commands for brain computer interface (BCI) technology. Patients with tetraplegia have used BCI technology to achieve an extraordinary degree of interaction with their local environment. However, current microelectrode arrays for BCIs lose the ability to record high-quality neural signals in the months-to-years following implantation. Very little is known regarding the dynamic response of neurons and vasculature in the months following electrode array implantation, but loss of structural integrity near the electrode may contribute to the degradation of recording signals. Here, we use in-vivo dual-modality imaging to characterize neuronal and vasculature structures in the same animal for 3 months following electrode insertion. We find ongoing neuronal atrophy, but relative vascular stability, in close proximity to the electrode, along with evidence suggesting links between rare, abrupt hypoxic events and neuronal process atrophy.
Collapse
|
18
|
Longitudinal multimodal assessment of neurodegeneration and vascular remodeling correlated with signal degradation in chronic cortical silicon microelectrodes. NEUROPHOTONICS 2020; 7:015004. [PMID: 32042853 PMCID: PMC6991888 DOI: 10.1117/1.nph.7.1.015004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Accepted: 01/14/2020] [Indexed: 05/19/2023]
Abstract
Significance: Cortically implanted microelectrode arrays provide a direct interface with neuronal populations and are used to restore movement capabilities and provide sensory feedback to patients with paralysis or amputation. Penetrating electrodes experience high rates of signal degradation within the first year that limit effectiveness and lead to eventual device failure. Aim: To assess vascular and neuronal changes over time in mice with implanted electrodes and examine the contribution of the brain tissue response to electrode performance. Approach: We used a multimodal approach combining in vivo electrophysiology and subcellular-level optical imaging. Results: At acute timescales, we observed structural damage from the mechanical trauma of electrode insertion, evidenced by severed dendrites in the electrode path and local hypofluorescence. Superficial vessel growth and remodeling occurred within the first few weeks in both electrode-implanted and window-only animals, but the deeper capillary growth evident in window-only animals was suppressed in electrode-implanted animals. After longer implantation periods, there was evidence of degeneration of transected dendrites superficial to the electrode path and localized neuronal cell body loss, along with deep vascular velocity changes near the electrode. Total spike rate (SR) across all animals reached a peak between 3 and 9 months postimplantation, then decreased. The local field potential signal remained relatively constant for up to 6 months, particularly in the high-gamma band, indicating long-term electrode viability and neuronal functioning at further distances from the electrode, but it showed a reduction in some animals at later time points. Most importantly, we found that progressive high-gamma and SR reductions both correlate positively with localized cell loss and decreasing capillary density within 100 μ m of the electrode. Conclusions: This multifaceted approach provided a more comprehensive picture of the ongoing biological response at the brain-electrode interface than can be achieved with postmortem histology alone and established a real-time relationship between electrophysiology and tissue damage.
Collapse
|
19
|
In vivo measurement of organelle motility in human retinal pigment epithelial cells. BIOMEDICAL OPTICS EXPRESS 2019; 10:4142-4158. [PMID: 31453000 PMCID: PMC6701538 DOI: 10.1364/boe.10.004142] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 06/24/2019] [Accepted: 06/24/2019] [Indexed: 05/18/2023]
Abstract
Retinal pigment epithelial (RPE) cells are well known to play a central role in the progression of numerous retinal diseases. Changes in the structure and function of these cells thus may serve as sensitive biomarkers of disease onset. While in vivo studies have focused on structural changes, functional ones may better capture cell health owing to their more direct connection to cell physiology. In this study, we developed a method based on adaptive optics optical coherence tomography (AO-OCT) and speckle field dynamics for characterizing organelle motility in individual RPE cells. We quantified the dynamics in terms of an exponential decay time constant, the time required for the speckle field to decorrelate. Using seven normal subjects, we found the RPE speckle field to decorrelate in about 5 s. This result has two fundamental implications for future clinical use. First, it establishes a path for generating a normative baseline to which motility of diseased RPE cells can be compared. Second, it predicts an AO-OCT image acquisition time that is 36 times faster than used in our earlier report for individuating RPE cells, thus a major improvement in clinical efficacy.
Collapse
|
20
|
Application of optical coherence tomography and optical path length method for monitoring corneal thickness and refractive index change during corneal cross-linking. APPLIED OPTICS 2019; 58:4616-4621. [PMID: 31251279 DOI: 10.1364/ao.58.004616] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 05/08/2019] [Indexed: 06/09/2023]
Abstract
Corneal cross-linking (CXL) using UVA irradiation with a riboflavin photosensitizer has emerged as a new treatment paradigm for corneal ectatic disorders. The thickness threshold for protection of intraocular structures has often been challenged with ongoing developments, and corneal thinning becomes an important safety concern, especially for patients with thin corneas. In this study with an ex vivo bovine eye model, we monitored corneal thinning and corneal refractive index changes using optical coherence tomography (OCT) integrated with an adaptation of the optical path length method. CXL experiments were performed based on the standard protocol that includes removal of the corneal epithelium to facilitate diffusion of riboflavin into the stroma. The corneal stromal thickness and group refractive index were measured by a 1310 nm Fourier-domain OCT imaging system at three critical points of the procedure: immediately after epithelial removal, after 30 min riboflavin instillation, and after 30 min UVA irradiation with continuing instillation. We found that the refractive index of the bovine cornea changed significantly from epithelial removal to riboflavin instillation and UVA irradiation, increasing from 1.377±0.005 (mean±standard deviation) after de-epithelization to 1.387±0.003 after 30 min instillation and 1.388±0.008 after subsequent irradiation. The corneas also underwent a considerable decrease (10%-20%) in stromal thickness with thinning of 95±29 μm (mean±standard deviation) after riboflavin instillation and a further decrease (∼5%) with thinning of 42±19 μm after UVA irradiation. Our study highlights the importance of corneal thickness monitoring during CXL, especially after riboflavin instillation when the decrease is the largest, to avoid delivering endothelial cytotoxic doses. An increase in refractive index heightens the concern for corneal thinning and the need for careful monitoring as a safety precaution.
Collapse
|
21
|
Toward optical coherence tomography angiography-based biomarkers to assess the safety of peripheral nerve electrostimulation. J Neural Eng 2019; 16:036024. [PMID: 30917357 PMCID: PMC6583899 DOI: 10.1088/1741-2552/ab1405] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE Peripheral nerves serve as a link between the central nervous system and its targets. Altering peripheral nerve activity through targeted electrical stimulation is being investigated as a therapy for modulating end organ function. To support rapid advancement in the field, novel approaches to predict and prevent nerve injury resulting from electrical stimulation must be developed to overcome the limitations of traditional histological methods. The present study aims to develop an optical imaging-based approach for real-time assessment of peripheral nerve injury associated with electrical stimulation. APPROACH We developed an optical coherence tomography (OCT) angiography system and a 3D printed stimulating nerve stabilizer (sNS) to assess the real-time microvascular and blood flow changes associated with electrical stimulation of peripheral nerves. We then compared the microvascular changes with established nerve function analysis and immunohistochemistry to correlate changes with nerve injury. MAIN RESULTS Electrical stimulation of peripheral nerves has a direct influence on vessel diameter and capillary flow. The stimulation used in this study did not alter motor function significantly, but a delayed onset of mechanical allodynia at lower thresholds was observed using a sensory function test. Immunohistochemical analysis pointed to an increased number of macrophages within nerve fascicles and axon sprouting potentially related to nerve injury. SIGNIFICANCE This study is the first to demonstrate the ability to image peripheral nerve microvasculature changes during electrical stimulation. This expands the knowledge in the field and can be used to develop potential biomarkers to predict nerve injury resulting from electrical stimulation.
Collapse
|
22
|
3-D printed photoreceptor phantoms for evaluating lateral resolution of adaptive optics imaging systems. OPTICS LETTERS 2019; 44:1825-1828. [PMID: 30933157 DOI: 10.1364/ol.44.001825] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 03/10/2019] [Indexed: 06/09/2023]
Abstract
With adaptive optics (AO), optical coherence tomography and scanning laser ophthalmoscopy imaging systems can resolve individual photoreceptor cells in living eyes, due to enhanced lateral spatial resolution. However, no standard test method exists for experimentally quantifying this parameter in ophthalmic AO imagers. Here, we present three-dimensional (3-D) printed phantoms, which enable the measurement of lateral resolution in an anatomically relevant manner. We used two-photon polymerization to fabricate two phantoms, which mimic the mosaic of cone photoreceptor outer segments at multiple retinal eccentricities. With these phantoms, we demonstrated that the resolution of two multimodal AO systems is similar to theoretical predictions, with some intriguing speckle effects.
Collapse
|
23
|
Trans-retinal cellular imaging with multimodal adaptive optics. BIOMEDICAL OPTICS EXPRESS 2018; 9:4246-4262. [PMID: 30615699 PMCID: PMC6157758 DOI: 10.1364/boe.9.004246] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 08/02/2018] [Accepted: 08/06/2018] [Indexed: 05/18/2023]
Abstract
Adaptive optics (AO), when coupled to different imaging modalities, has enabled resolution of various cell types across the entire retinal depth in the living human eye. Extraction of information from retinal cells is optimal when their optical properties, structure, and physiology are matched to the unique capabilities of each imaging modality. Despite the earlier success of multimodal AO (mAO) approaches, the full capabilities of the individual imaging modalities were often diminished rather than enhanced when integrated into multimodal platforms. Furthermore, many mAO designs added unnecessary complexity, making clinical translation difficult. In this study, we present a novel mAO system that combines two complementary approaches, scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT), in one instrument using a simplified optical design, flexible alternation of scanning modes, and independent focus control. The mAO system imaging performance was demonstrated by visualization of cells in their mosaic arrangement across the full depth of the retina in three human subjects, including microglia, nerve fiber bundles, retinal ganglion cells and axons, and capillaries in the inner retina and foveal cones, peripheral rods, and retinal pigment epithelial cells in the outer retina. Multimodal AO is a powerful tool to capture the most complete picture of retinal health.
Collapse
|
24
|
Alterations in neurovascular coupling following acute traumatic brain injury. NEUROPHOTONICS 2017; 4:045007. [PMID: 29296629 PMCID: PMC5741992 DOI: 10.1117/1.nph.4.4.045007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Accepted: 11/28/2017] [Indexed: 06/07/2023]
Abstract
Following acute traumatic brain injury (TBI), timely transport to a hospital can significantly improve the prognosis for recovery. There is, however, a dearth of quantitative biomarkers for brain injury that can be rapidly acquired and interpreted in active, field environments in which TBIs are frequently incurred. We explored potential functional indicators for TBI that can be noninvasively obtained through portable detection modalities, namely optical and electrophysiological approaches. By combining diffuse correlation spectroscopy with colocalized electrophysiological measurements in a mouse model of TBI, we observed concomitant alterations in sensory-evoked cerebral blood flow (CBF) and electrical potentials following controlled cortical impact. Injury acutely reduced the peak amplitude of both electrophysiological and CBF responses, which mostly recovered to baseline values within 30 min, and intertrial variability for these parameters was also acutely altered. Notably, the postinjury dynamics of the CBF overshoot and undershoot amplitudes differed significantly; whereas the amplitude of the initial peak of stimulus-evoked CBF recovered relatively rapidly, the ensuing undershoot did not appear to recover within 30 min of injury. Additionally, acute injury induced apparent low-frequency oscillatory behavior in CBF ([Formula: see text]). Histological assessment indicated that these physiological alterations were not associated with any major, persisting anatomical changes. Several time-domain features of the blood flow and electrophysiological responses showed strong correlations in recovery kinetics. Overall, our results reveal an array of stereotyped, injury-induced alterations in electrophysiological and hemodynamic responses that can be rapidly obtained using a combination of portable detection techniques.
Collapse
|
25
|
Optic Nerve Head Measurements With Optical Coherence Tomography: A Phantom-Based Study Reveals Differences Among Clinical Devices. Invest Ophthalmol Vis Sci 2017; 57:OCT413-20. [PMID: 27409500 PMCID: PMC4968925 DOI: 10.1167/iovs.15-18738] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Optical coherence tomography (OCT) can monitor for glaucoma by measuring dimensions of the optic nerve head (ONH) cup and disc. Multiple clinical studies have shown that different OCT devices yield different estimates of retinal dimensions. We developed phantoms mimicking ONH morphology as a new way to compare ONH measurements from different clinical OCT devices. Methods Three phantoms were fabricated to model the ONH: One normal and two with glaucomatous anatomies. Phantoms were scanned with Stratus, RTVue, and Cirrus clinical devices, and with a laboratory OCT system as a reference. We analyzed device-reported ONH measurements of cup-to-disc ratio (CDR) and cup volume and compared them with offline measurements done manually and with a custom software algorithm, respectively. Results The mean absolute difference between clinical devices with device-reported measurements versus offline measurements was 0.082 vs. 0.013 for CDR and 0.044 mm3 vs. 0.019 mm3 for cup volume. Statistically significant differences between devices were present for 16 of 18 comparisons of device-reported measurements from the phantoms. Offline Cirrus measurements tended to be significantly different from those from Stratus and RTVue. Conclusions The interdevice differences in CDR and cup volume are primarily caused by the devices' proprietary ONH analysis algorithms. The three devices yield more similar ONH measurements when a consistent offline analysis technique is applied. Scan pattern on the ONH also may be a factor in the measurement differences. This phantom-based study has provided unique insights into characteristics of OCT measurements of the ONH.
Collapse
|
26
|
Acute insertion effects of penetrating cortical microelectrodes imaged with quantitative optical coherence angiography. NEUROPHOTONICS 2016; 3:025002. [PMID: 32064297 PMCID: PMC7011942 DOI: 10.1117/1.nph.3.2.025002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Accepted: 03/16/2016] [Indexed: 05/16/2023]
Abstract
The vascular response during cortical microelectrode insertion was measured with amplitude decorrelation-based quantitative optical coherence angiography (OCA). Four different shank-style microelectrode configurations were inserted in murine motor cortex beneath a surgically implanted window in discrete steps while OCA images were collected and processed for angiography and flowmetry. Quantitative measurements included tissue displacement (measured by optical flow), perfused capillary density, and capillary flow velocity. The primary effect of insertion was mechanical perturbation, the effects of which included tissue displacement, arteriolar rupture, and compression of a branch of the anterior cerebral artery causing a global decrease in flow. Other effects observed included local flow drop-out in the region immediately surrounding the microelectrode. The mean basal capillary network velocity for all animals was 0.23 ( ± 0.05 SD ) and 0.18 ( ± 0.07 SD ) mm / s for capillaries from 100 to 300 μ m and 300 to 500 μ m , respectively. Upon insertion, the 2-shank electrode arrays caused a decrease in capillary flow density and velocity, while the results from other configurations were not different from controls. The proximity to large vessels appears to play a larger role than the array configuration. These results can guide neurosurgeons and electrode designers to minimize trauma and ischemia during microelectrode insertion.
Collapse
|
27
|
Closed loop tracked Doppler optical coherence tomography based heart monitor for the Drosophila melanogaster larvae. JOURNAL OF BIOPHOTONICS 2016; 9:246-52. [PMID: 25924107 DOI: 10.1002/jbio.201500007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Revised: 03/22/2015] [Accepted: 04/01/2015] [Indexed: 05/19/2023]
Abstract
This paper presents a novel instrument for biosciences, useful for studies of moving embryos. A dual sequential imaging/measurement channel is assembled via a closed-loop tracking architecture. The dual channel system can operate in two regimes: (i) single-point Doppler signal monitoring or (ii) fast 3-D swept source OCT imaging. The system is demonstrated for characterizing cardiac dynamics in Drosophila melanogaster larva. Closed loop tracking enables long term in vivo monitoring of the larvae heart without anesthetic or physical restraint. Such an instrument can be used to measure subtle variations in the cardiac behavior otherwise obscured by the larvae movements. A fruit fly larva (top) was continuously tracked for continuous remote monitoring. A heartbeat trace of freely moving larva (bottom) was obtained by a low coherence interferometry based doppler sensing technique.
Collapse
|
28
|
Image quality metrics for optical coherence angiography. BIOMEDICAL OPTICS EXPRESS 2015; 6:2435-2447. [PMID: 26203372 PMCID: PMC4505700 DOI: 10.1364/boe.6.002435] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Revised: 05/13/2015] [Accepted: 06/09/2015] [Indexed: 05/20/2023]
Abstract
We characterized image quality in optical coherence angiography (OCA) en face planes of mouse cortical capillary network in terms of signal-to-noise ratio (SNR) and Weber contrast (Wc) through a novel mask-based segmentation method. The method was used to compare two adjacent B-scan processing algorithms, (1) average absolute difference (AAD) and (2) standard deviation (SD), while varying the number of lateral cross-sections acquired (also known as the gate length, N). AAD and SD are identical at N = 2 and exhibited similar image quality for N<10. However, AAD is relatively less susceptible to bulk tissue motion artifact than SD. SNR and Wc were 15% and 35% higher for AAD from N = 25 to 100. In addition data sets were acquired with two objective lenses with different magnifications to quantify the effect of lateral resolution on fine capillary detection. The lower power objective yielded a significant mean broadening of 17% in Full Width Half Maximum (FWHM) diameter. These results may guide study and device designs for OCA capillary and blood flow quantification.
Collapse
|
29
|
The use of time-lapse optical coherence tomography to image the effects of microapplied toxins on the retina. Invest Ophthalmol Vis Sci 2014; 56:587-97. [PMID: 25525175 DOI: 10.1167/iovs.14-15594] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE We developed a novel technique for accelerated drug screening and retinotoxin characterization using time-lapse optical coherence tomography (OCT) and a drug microapplication device. METHODS Using an ex vivo rabbit eyecup preparation, we studied retinotoxin effects in real-time by microperfusing small retinal areas under a transparent fluoropolymer tube. Known retinotoxic agents were applied to the retina for 5-minute periods, while changes in retinal structure, thickness, and reflectance were monitored with OCT. The OCT images of two agents with dissimilar mechanisms, cyanide and kainic acid, were compared to their structural changes seen histologically. RESULTS We found the actions of retinotoxic agents tested could be classified broadly into two distinct types: (1) agents that induce neuronal depolarization, such as kainic acid, causing increases in OCT reflectivity or thickness of the inner plexiform and nuclear layers, and decreased reflectivity of the outer retina; and (2) agents that disrupt mitochondrial function, such as cyanide, causing outer retinal structural changes as evidenced by a reduction in the OCT reflectivity of the photoreceptor outer segment and pigment epithelium layers. CONCLUSIONS Retinotoxin-induced changes in retinal layer reflectivity and thickness under the microperfusion tube in OCT images closely matched the histological evidence of retinal injury. Time-lapse OCT imaging of the microperfused local retina has the potential to accelerate drug retinotoxicological screening and expand the use of OCT as an evaluation tool for preclinical animal testing.
Collapse
|
30
|
In vivo three-dimensional characterization of the healthy human lamina cribrosa with adaptive optics spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci 2014; 55:6459-66. [PMID: 25228539 DOI: 10.1167/iovs.14-15177] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To characterize the in vivo three-dimensional (3D) lamina cribrosa (LC) microarchitecture of healthy eyes using adaptive optics spectral-domain optical coherence tomography (AO-SDOCT). METHODS A multimodal retinal imaging system with a light source centered at 1050 nm and AO confocal scanning laser ophthalmoscopy was used in this study. One randomly selected eye from 18 healthy subjects was scanned in a 6° × 6° window centered on the LC. Subjects also underwent scanning with Cirrus HD-OCT. Lamina cribrosa microarchitecture was semiautomatically segmented and quantified for connective tissue volume fraction (CTVF), beam thickness, pore diameter, pore area, and pore aspect ratio. The LC was assessed in central and peripheral regions of equal areas and quadrants and with depth. A linear mixed effects model weighted by the fraction of visible LC was used to compare LC structure between regions. RESULTS The nasal quadrant was excluded due to poor visualization. The central sector showed greater CTVF and thicker beams as compared to the periphery (P < 0.01). Both superior and inferior quadrants showed greater CTVF, pore diameter, and pore mean area than the temporal quadrant (P < 0.05). Depth analysis showed that the anterior and posterior aspects of the LC contained smaller pores with greater density and thinner beams as compared to the middle third (P < 0.05). The anterior third also showed a greater CTVF than the middle third (P < 0.05). CONCLUSIONS In vivo analysis of healthy eyes using AO-SDOCT showed significant, albeit small, regional variation in LC microarchitecture by quadrant, radially, and with depth, which should be considered in further studies of the LC.
Collapse
|
31
|
Longitudinal vascular dynamics following cranial window and electrode implantation measured with speckle variance optical coherence angiography. BIOMEDICAL OPTICS EXPRESS 2014; 5:2823-36. [PMID: 25136505 PMCID: PMC4133009 DOI: 10.1364/boe.5.002823] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Revised: 07/14/2014] [Accepted: 07/18/2014] [Indexed: 05/18/2023]
Abstract
Speckle variance optical coherence angiography (OCA) was used to characterize the vascular tissue response from craniotomy, window implantation, and electrode insertion in mouse motor cortex. We observed initial vasodilation ~40% greater than original diameter 2-3 days post-surgery (dps). After 4 weeks, dilation subsided in large vessels (>50 µm diameter) but persisted in smaller vessels (25-50 µm diameter). Neovascularization began 8-12 dps and vessel migration continued throughout the study. Vasodilation and neovascularization were primarily associated with craniotomy and window implantation rather than electrode insertion. Initial evidence of capillary re-mapping in the region surrounding the implanted electrode was manifest in OCA image dissimilarity. Further investigation, including higher resolution imaging, is required to validate the finding. Spontaneous lesions also occurred in many electrode animals, though the inception point appeared random and not directly associated with electrode insertion. OCA allows high resolution, label-free in vivo visualization of neurovascular tissue, which may help determine any biological contribution to chronic electrode signal degradation. Vascular and flow-based biomarkers can aid development of novel neural prostheses.
Collapse
|
32
|
Adaptive optics optical coherence tomography with dynamic retinal tracking. BIOMEDICAL OPTICS EXPRESS 2014; 5:2262-84. [PMID: 25071963 PMCID: PMC4102363 DOI: 10.1364/boe.5.002262] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2014] [Revised: 06/11/2014] [Accepted: 06/11/2014] [Indexed: 05/04/2023]
Abstract
Adaptive optics optical coherence tomography (AO-OCT) is a highly sensitive and noninvasive method for three dimensional imaging of the microscopic retina. Like all in vivo retinal imaging techniques, however, it suffers the effects of involuntary eye movements that occur even under normal fixation. In this study we investigated dynamic retinal tracking to measure and correct eye motion at KHz rates for AO-OCT imaging. A customized retina tracking module was integrated into the sample arm of the 2nd-generation Indiana AO-OCT system and images were acquired on three subjects. Analyses were developed based on temporal amplitude and spatial power spectra in conjunction with strip-wise registration to independently measure AO-OCT tracking performance. After optimization of the tracker parameters, the system was found to correct eye movements up to 100 Hz and reduce residual motion to 10 µm root mean square. Between session precision was 33 µm. Performance was limited by tracker-generated noise at high temporal frequencies.
Collapse
|
33
|
Repeatability of in vivo 3D lamina cribrosa microarchitecture using adaptive optics spectral domain optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2014; 5:1114-23. [PMID: 24761293 PMCID: PMC3986004 DOI: 10.1364/boe.5.001114] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 02/04/2014] [Accepted: 02/21/2014] [Indexed: 05/05/2023]
Abstract
We demonstrate the repeatability of lamina cribrosa (LC) microarchitecture for in vivo 3D optical coherence tomography (OCT) scans of healthy, glaucoma suspects, and glaucomatous eyes. Eyes underwent two scans using a prototype adaptive optics spectral domain OCT (AO-SDOCT) device from which LC microarchitecture was semi-automatically segmented. LC segmentations were used to quantify pore and beam structure through several global microarchitecture parameters. Repeatability of LC microarchitecture was assessed qualitatively and quantitatively by calculating parameter imprecision. For all but one parameters (pore volume) measurement imprecision was <4.7% of the mean value, indicating good measurement reproducibility. Imprecision ranged between 27.3% and 54.5% of the population standard deviation for each parameter, while there was not a significant effect on imprecision due to disease status, indicating utility in testing for LC structural trends.
Collapse
|
34
|
Retina-simulating phantom for optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2014; 19:21106. [PMID: 24042445 DOI: 10.1117/1.jbo.19.2.021106] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Accepted: 08/13/2013] [Indexed: 05/19/2023]
Abstract
Optical coherence tomography (OCT) is a rapidly growing imaging modality, particularly in the field of ophthalmology. Accurate early diagnosis of diseases requires consistent and validated imaging performance. In contrast to more well-established medical imaging modalities, no standardized test methods currently exist for OCT quality assurance. We developed a retinal phantom which mimics the thickness and near-infrared optical properties of each anatomical retinal layer as well as the surface topography of the foveal pit. The fabrication process involves layer-by-layer spin coating of nanoparticle-embedded silicone films followed by laser micro-etching to modify the surface topography. The thickness of each layer and dimensions of the foveal pit are measured with high precision. The phantom is embedded into a commercially available, water-filled model eye to simulate ocular dispersion and emmetropic refraction, and for ease of use with clinical OCT systems. The phantom was imaged with research and clinical OCT systems to assess image quality and software accuracy. Our results indicate that this phantom may serve as a useful tool to evaluate and standardize OCT performance.
Collapse
|
35
|
Abstract
We present a new application of optical coherence tomography (OCT), widely used in biomedical imaging, to flow analysis in near-wall hydrodynamics for marine research. This unique capability, called OCT micro-particle image velocimetry, provides a high-resolution view of microscopic flow phenomena and measurement of flow statistics within the first millimeter of a boundary layer. The technique is demonstrated in a small flow cuvette and in a water tunnel.
Collapse
|
36
|
Accurate prediction of collapse temperature using optical coherence tomography-based freeze-drying microscopy. J Pharm Sci 2013; 102:1773-1785. [PMID: 23681564 PMCID: PMC10860704 DOI: 10.1002/jps.23516] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2012] [Revised: 02/26/2013] [Accepted: 03/04/2013] [Indexed: 02/04/2023]
Abstract
The objective of this study was to assess the feasibility of developing and applying a laboratory tool that can provide three-dimensional product structural information during freeze-drying and which can accurately characterize the collapse temperature (Tc ) of pharmaceutical formulations designed for freeze-drying. A single-vial freeze dryer coupled with optical coherence tomography freeze-drying microscopy (OCT-FDM) was developed to investigate the structure and Tc of formulations in pharmaceutically relevant products containers (i.e., freeze-drying in vials). OCT-FDM was used to measure the Tc and eutectic melt of three formulations in freeze-drying vials. The Tc as measured by OCT-FDM was found to be predictive of freeze-drying with a batch of vials in a conventional laboratory freeze dryer. The freeze-drying cycles developed using OCT-FDM data, as compared with traditional light transmission freeze-drying microscopy (LT-FDM), resulted in a significant reduction in primary drying time, which could result in a substantial reduction of manufacturing costs while maintaining product quality. OCT-FDM provides quantitative data to justify freeze-drying at temperatures higher than the Tc measured by LT-FDM and provides a reliable upper limit to setting a product temperature in primary drying.
Collapse
|
37
|
Automated lamina cribrosa microstructural segmentation in optical coherence tomography scans of healthy and glaucomatous eyes. BIOMEDICAL OPTICS EXPRESS 2013; 4:2596-608. [PMID: 24298418 PMCID: PMC3829553 DOI: 10.1364/boe.4.002596] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2013] [Revised: 10/17/2013] [Accepted: 10/17/2013] [Indexed: 05/05/2023]
Abstract
We demonstrate an automated segmentation method for in-vivo 3D optical coherence tomography (OCT) imaging of the lamina cribrosa (LC). Manual segmentations of coronal slices of the LC were used as a gold standard in parameter selection and evaluation of the automated technique. The method was validated using two prototype OCT devices; each had a subject cohort including both healthy and glaucomatous eyes. Automated segmentation of in-vivo 3D LC OCT microstructure performed comparably to manual segmentation and is useful for investigative research and in clinical quantification of the LC.
Collapse
|
38
|
Multimodal adaptive optics retinal imager: design and performance. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2012; 29:2598-607. [PMID: 23455909 PMCID: PMC6360942 DOI: 10.1364/josaa.29.002598] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) and scanning laser ophthalmoscopy (SLO) are complementary imaging modalities, the combination of which can provide clinicians with a wealth of information to detect retinal diseases, monitor disease progression, or assess new therapies. Adaptive optics (AO) is a tool that enables correction of wavefront distortions from ocular aberrations. We have developed a multimodal adaptive optics system (MAOS) for high-resolution multifunctional use in a variety of research and clinical applications. The system integrates both OCT and SLO imaging channels into an AO beam path. The optics and hardware were designed with specific features for simultaneous SLO/OCT output, for high-fidelity AO correction, for use in humans, primates, and small animals, and for efficient location and orientation of retinal regions of interest. The MAOS system was tested on human subjects and rodents. The design, performance characterization, and initial representative results from the human and animal studies are presented and discussed.
Collapse
|
39
|
In vivo imaging of photoreceptor disruption associated with age-related macular degeneration: A pilot study. Lasers Surg Med 2012; 44:603-10. [PMID: 22930575 DOI: 10.1002/lsm.22070] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/07/2012] [Indexed: 11/10/2022]
Abstract
BACKGROUND AND OBJECTIVE Age-related macular degeneration is one of the leading causes of vision loss in the developed world. As the disease progresses, the central part of the retina, called the macula, is compromised leading to a disruption of both structure and visual function. In this study, we investigate the disruption of macular photoreceptor cells in vivo as a function of disease stage in patients with the dry form of age-related macular degeneration AMD. MATERIALS AND METHODS An investigational confocal Adaptive Optics Scanning Laser Ophthalmoscope (AO-SLO) was used to obtain high resolution images of the macular photoreceptor mosaic in patients previously diagnosed with AMD. Four patients were selected as representative cases, comprising each of the four clinical stages of AMD progression. RESULTS AO-SLO imaging revealed slight disruption in the photoreceptor mosaic in early stage AMD due to focal drusen formation and identified several small drusen deposits that were not observed with standard clinical imaging techniques. An increase in photoreceptor disruption was visualized within the macula in direct correlation with the stage of AMD progression leading to a decrease in visual acuity. Large coalescent drusen and areas of geographic atrophy in advanced stage dry AMD exhibited a significant decrease in visible photoreceptor density. Significant decrease in photoreceptor counts (∼35-50%) were observed when comparing earlier stages of AMD progression (Categories I and II) to later stages of the disease (Categories III and IV). CONCLUSIONS This study demonstrates the capabilities of adaptive optics retinal imaging to monitor disruption of individual photoreceptor cells as a function of disease progression yielding valuable diagnostic findings in early stage AMD beyond what can be learned about the health of photoreceptors using conventional retinal imaging techniques. Lasers Surg. Med. 44: 603-610, 2012. © 2012 Wiley Periodicals, Inc.
Collapse
|
40
|
Imaging flow dynamics in murine coronary arteries with spectral domain optical Doppler tomography. BIOMEDICAL OPTICS EXPRESS 2012; 3:701-14. [PMID: 22574259 PMCID: PMC3345800 DOI: 10.1364/boe.3.000701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2011] [Revised: 01/27/2012] [Accepted: 01/18/2012] [Indexed: 05/11/2023]
Abstract
Blood flow in murine epicardial and intra-myocardial coronary arteries was measured in vivo with spectral domain optical Doppler tomography (SD-ODT). Videos at frame rates up to 180 fps were collected and processed to extract phase shifts associated with moving erythrocytes in the coronary arteries. Radial averaging centered on the vessel lumen provided spatial smoothing of phase noise in a single cross-sectional frame for instantaneous peak velocity measurement without distortion of the flow profile. Temporal averaging synchronized to the cardiac cycle (i.e., gating) was also performed to reduce phase noise, although resulting in lower flow profiles. The vessel angle with respect to incident imaging beam was measured with three-dimensional raster scans collected from the same region as the high speed cross-sectional scans. The variability in peak phase measurement was 10-15% from cycle to cycle on a single animal but larger for measurements among animals. The inter-subject variability is attributed to factors related to real physiological and anatomical differences, instrumentation variables, and measurement error. The measured peak instantaneous flow velocity in a ~40-µm diameter vessel was 23.5 mm/s (28 kHz Doppler phase shift). In addition to measurement of the flow velocity, we observed several dynamic features of the vessel and surrounding myocardium in the intensity and phase sequences, including asymmetric vessel deformation and rapid flow reversal immediately following maximum flow, in confirmation of known coronary artery flow dynamics. SD-ODT is an optical imaging tool that can provide in vivo measures of structural and functional information on cardiac function in small animals.
Collapse
|
41
|
Angiography with a multifunctional line scanning ophthalmoscope. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:026008. [PMID: 22463040 PMCID: PMC3382353 DOI: 10.1117/1.jbo.17.2.026008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2011] [Revised: 12/14/2011] [Accepted: 12/15/2011] [Indexed: 05/24/2023]
Abstract
A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal tracker (RT) and a photodynamic therapy laser treatment port. The mLSO was tested in a pilot clinical study on human subjects with and without retinal disease. The instrument exhibited robust retinal tracking and high-contrast line scanning imaging. The FA and ICGA angiograms showed a similar appearance of hyper- and hypo-pigmented disease features and a nearly equivalent resolution of fine capillaries compared to a commercial flood-illumination fundus imager. An mLSO-based platform will enable researchers and clinicians to image human and animal eyes with a variety of modalities and deliver therapeutic beams from a single automated interface. This approach has the potential to improve patient comfort and reduce imaging session times, allowing clinicians to better diagnose, plan, and conduct patient procedures with improved outcomes.
Collapse
|
42
|
Fluorescence-guided optical coherence tomography imaging for colon cancer screening: a preliminary mouse study. BIOMEDICAL OPTICS EXPRESS 2012; 3:178-91. [PMID: 22254178 PMCID: PMC3255336 DOI: 10.1364/boe.3.000178] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2011] [Revised: 12/07/2011] [Accepted: 12/18/2011] [Indexed: 05/20/2023]
Abstract
A new concept for cancer screening has been preliminarily investigated. A cancer targeting agent loaded with a near-infrared (NIR) dye was topically applied on the tissue to highlight cancer-suspect locations and guide optical coherence tomography (OCT) imaging, which was used to further investigate tissue morphology at the micron scale. A pilot study on ApcMin mice has been performed to preliminarily test this new cancer screening approach. As a cancer-targeting agent, poly(epsilon-caprolactone) microparticles (PCLMPs), labeled with a NIR dye and functionalized with an RGD (argenine-glycine-aspartic acid) peptide, were used. This agent recognizes the α(ν)β(3) integrin receptor (ABIR), which is over-expressed by epithelial cancer cells. The contrast agent was administered topically in vivo in mouse colon. After incubation, the animals were sacrificed and fluorescence-guided high resolution optical coherence tomography (OCT) imaging was used to visualize colon morphology. The preliminary results show preferential staining of the abnormal tissue, as indicated by both microscopy and laser-induced fluorescence imaging, and OCT's capability to differentiate between normal mucosal areas, early dysplasia, and adenocarcinoma. Although very preliminary, the results of this study suggest that fluorescence-guided OCT imaging might be a suitable approach for cancer screening. If successful, this approach could be used by clinicians to more reliably diagnose early stage cancers in vivo.
Collapse
|
43
|
Optical coherence tomography-based freeze-drying microscopy. BIOMEDICAL OPTICS EXPRESS 2012; 3:55-63. [PMID: 22254168 PMCID: PMC3255342 DOI: 10.1364/boe.3.000055] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2011] [Revised: 12/01/2011] [Accepted: 12/02/2011] [Indexed: 05/31/2023]
Abstract
A new type of freeze-drying microscope based upon time-domain optical coherence tomography is presented here (OCT-FDM). The microscope allows for real-time, in situ 3D imaging of pharmaceutical formulations in vials relevant for manufacturing processes with a lateral resolution of <7 μm and an axial resolution of <5 μm. Correlation of volumetric structural imaging with product temperature measured during the freeze-drying cycle allowed investigation of structural changes in the product and determination of the temperature at which the freeze-dried cake collapses. This critical temperature is the most important parameter in designing freeze-drying processes of pharmaceutical products.
Collapse
|
44
|
Differentiation of pancreatic cysts with optical coherence tomography (OCT) imaging: an ex vivo pilot study. BIOMEDICAL OPTICS EXPRESS 2011; 2:2372-2382. [PMID: 21833374 PMCID: PMC3149535 DOI: 10.1364/boe.2.002372] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 07/11/2011] [Accepted: 07/20/2011] [Indexed: 05/29/2023]
Abstract
We demonstrate for the first time that optical coherence tomography (OCT) imaging can reliably distinguish between morphologic features of low risk pancreatic cysts (i.e., pseudocysts and serous cystadenomas) and high risk pancreatic cysts (i.e., mucinous cystic neoplasms and intraductal papillary mucinous neoplasms). In our study fresh pancreatectomy specimens (66) from patients with cystic lesions undergoing surgery were acquired and examined with OCT. A training set of 20 pathology-OCT correlated tissue specimens were used to develop criteria for differentiating between low and high risk cystic lesions. A separate (validation) set of 46 specimens were used to test the OCT criteria by three clinicians, blinded to histopathology findings. Histology was finally used as a 'gold' standard for testing OCT findings. OCT was able to reveal specific morphologic features of pancreatic cysts and thus to differentiate between low-risk and high-risk cysts with over 95% sensitivity and specificity. This pilot study suggests that OCT could be used by clinicians in the future to more reliably differentiate between benign and potentially malignant pancreatic cysts. However, in vivo use of OCT requires a probe that has to fit the bore of the pancreas biopsy needle. Therefore, we have developed such probes and planned to start an in vivo pilot study within the very near future.
Collapse
|
45
|
Preliminary evaluation of a nanotechnology-based approach for the more effective diagnosis of colon cancers. Nanomedicine (Lond) 2011; 5:1467-79. [PMID: 21128727 DOI: 10.2217/nnm.10.93] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
AIM The goal of this research was to develop and preliminarily test a novel technology and instrumentation that could help to significantly increase the diagnostic yield of current colon cancer screening procedures. This technology is based on a combined fluorescence-optical coherence tomography (OCT) imaging, and topical delivery of a cancer-targeting agent. MATERIALS & METHODS Gold colloid-adsorbed poly(ε-caprolactone) microparticles were labeled with a near-infrared dye, and functionalized with argentine-glycine-aspartic acid (RGD peptide) to effectively target cancer tissue, and enhance fluorescence-imaging contrast. The RGD peptide recognizes the α(v)β(3)-integrin receptor, which is overexpressed by epithelial cancer cells. OCT was used under fluorescence guidance to visualize tissue morphology and, thus, to serve as a confirmatory tool for cancer presence. RESULTS A preliminary testing of this technology on human colon cancer cell lines, a mouse model of colon cancer, as well as human colon tissue specimens, was performed. Strong binding of microparticles to cancer cells and no binding to cells that do not significantly express integrins, such as mouse fibroblasts, was observed. Preferential binding to cancer tissue was also observed. Strong fluorescence signals were obtained from cancer tissue, owing to the efficient binding of the contrast agent. OCT imaging was capable of revealing clear differences between normal and cancer tissue. CONCLUSION A dual-modality imaging approach combined with topical delivery of a cancer-targeting contrast agent has been preliminarily tested for colon cancer diagnosis. Preferential binding of the contrast agent to cancer tissue allowed the cancer-suspicious locations to be highlighted and, thus, guided OCT imaging to visualize tissue morphology and determine tissue type. If successful, this multimodal approach might help to increase the sensitivity and the specificity of current colon cancer-screening procedures in the future.
Collapse
|
46
|
Modeling the foveal cone mosaic imaged with adaptive optics scanning laser ophthalmoscopy. OPTICS EXPRESS 2010; 18:24902-16. [PMID: 21164835 PMCID: PMC3408900 DOI: 10.1364/oe.18.024902] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2010] [Revised: 10/13/2010] [Accepted: 10/22/2010] [Indexed: 05/18/2023]
Abstract
To better understand the limitations of high-resolution adaptive optics scanning laser ophthalmoscopy (AOSLO), we describe an imaging model that examines the smallest cone photoreceptors in the fovea of normal human subjects and analyze how different factors contribute to their resolution. The model includes basic optical factors such as wavelength and pupil size, and defines limits caused by source coherence which are specific to the AOSLO imaging modality as well as foveal cone structure. The details of the model, its implications for imaging, and potential techniques to circumvent the limitations are discussed in this paper.
Collapse
|
47
|
Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2010; 27:A265-77. [PMID: 21045887 PMCID: PMC3071649 DOI: 10.1364/josaa.27.00a265] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
We have developed a new, unified implementation of the adaptive optics scanning laser ophthalmoscope (AOSLO) incorporating a wide-field line-scanning ophthalmoscope (LSO) and a closed-loop optical retinal tracker. AOSLO raster scans are deflected by the integrated tracking mirrors so that direct AOSLO stabilization is automatic during tracking. The wide-field imager and large-spherical-mirror optical interface design, as well as a large-stroke deformable mirror (DM), enable the AOSLO image field to be corrected at any retinal coordinates of interest in a field of >25 deg. AO performance was assessed by imaging individuals with a range of refractive errors. In most subjects, image contrast was measurable at spatial frequencies close to the diffraction limit. Closed-loop optical (hardware) tracking performance was assessed by comparing sequential image series with and without stabilization. Though usually better than 10 μm rms, or 0.03 deg, tracking does not yet stabilize to single cone precision but significantly improves average image quality and increases the number of frames that can be successfully aligned by software-based post-processing methods. The new optical interface allows the high-resolution imaging field to be placed anywhere within the wide field without requiring the subject to re-fixate, enabling easier retinal navigation and faster, more efficient AOSLO montage capture and stitching.
Collapse
|
48
|
High resolution multimodal clinical ophthalmic imaging system. OPTICS EXPRESS 2010; 18:11607-21. [PMID: 20589021 PMCID: PMC2958093 DOI: 10.1364/oe.18.011607] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2010] [Revised: 04/29/2010] [Accepted: 05/08/2010] [Indexed: 05/18/2023]
Abstract
We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa. The SSOCT channel operates at a wavelength of 1 microm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. This AO system is designed for use in clinical populations; a dual deformable mirror (DM) configuration allows simultaneous low- and high-order aberration correction over a large range of refractions and ocular media quality. The system also includes a wide field (33 deg.) line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation, an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of lateral eye motion, and a high-resolution LCD-based fixation target for presentation of visual cues. The system was tested in human subjects without retinal disease for performance optimization and validation. We were able to resolve and quantify cone photoreceptors across the macula to within approximately 0.5 deg (approximately 100-150 microm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve features deep into the choroid. The prototype presented here is the first of a new class of powerful flexible imaging platforms that will provide clinicians and researchers with high-resolution, high performance adaptive optics imaging to help guide therapies, develop new drugs, and improve patient outcomes.
Collapse
|
49
|
Optical coherence tomography imaging for cancer diagnosis and therapy guidance. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2010; 2009:4067-9. [PMID: 19964101 DOI: 10.1109/iembs.2009.5333198] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Optical Coherence Tomography (OCT) is an emerging optical technology that has shown great promise for early cancer detection. Using backreflected light to visualize tissue microstructure, OCT can provide information on nuclear size and shape, nuclear-to-cytoplasmic ratio, and the organization and structure of glands. It can also provide functional information, like blood flow, tissue birefringence, etc. These capabilities could potentially be employed in three ways: as a primary diagnostic test to replace biopsy, as a screening tool to direct biopsy, and as a diagnostic tool to guide therapy and monitor therapy response. In this paper we present an application of OCT for pancreatic cancer diagnosis and therapy guidance.
Collapse
|
50
|
Abstract
We have developed a compact retinal imager that integrates adaptive optics (AO) into a line scanning ophthalmoscope (LSO). The bench-top AO-LSO instrument significantly reduces the size, complexity, and cost of research AO scanning laser ophthalmoscopes (AOSLOs), for the purpose of moving adaptive optics imaging more rapidly into routine clinical use. The AO-LSO produces high resolution retinal images with only one moving part and a significantly reduced instrument footprint and number of optical components. The AO-LSO has a moderate field of view (5.5 deg), which allows montages of the macula or other targets to be obtained more quickly and efficiently. In a preliminary human subjects investigation, photoreceptors could be resolved and counted within approximately 0.5 mm of the fovea. Photoreceptor counts matched closely to previously reported histology. The capillaries surrounding the foveal avascular zone could be resolved, as well as cells flowing within them. Individual nerve fiber bundles could be resolved, especially near the optic nerve head, as well as other structures such as the lamina cribrosa. In addition to instrument design, fabrication, and testing, software algorithms were developed for automated image registration and cone counting.
Collapse
|