1
|
Katan M, Pearl O, Tzroya A, Duadi H, Fixler D. A Self-Calibrated Single Wavelength Biosensor for Measuring Oxygen Saturation. Biosensors (Basel) 2024; 14:132. [PMID: 38534239 DOI: 10.3390/bios14030132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 02/24/2024] [Accepted: 03/01/2024] [Indexed: 03/28/2024]
Abstract
Traditional methods for measuring blood oxygen use multiple wavelengths, which produce an intrinsic error due to ratiometric measurements. These methods assume that the absorption changes with the wavelength, but in fact the scattering changes as well and cannot be neglected. We found that if one measures in a specific angle around a cylindrical tissue, called the iso-pathlength (IPL) point, the reemitted light intensity is unaffected by the tissue's scattering. Therefore, the absorption can be isolated from the scattering, which allows the extraction of the subject's oxygen saturation. In this work, we designed an optical biosensor for reading the light intensity reemitted from the tissue, using a single light source and multiple photodetectors (PDs), with one of them in the IPL point's location. Using this bio-device, we developed a methodology to extract the arterial oxygen saturation using a single wavelength light source. We proved this method is not dependent on the light source and is applicable to different measurement locations on the body, with an error of 0.5%. Moreover, we tested thirty-eight males and females with the biosensor under normal conditions. Finally, we show the results of measuring subjects in a hypoxic chamber that simulates extreme conditions with low oxygen.
Collapse
Affiliation(s)
- Michal Katan
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Ori Pearl
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Alon Tzroya
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Hamootal Duadi
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Dror Fixler
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
2
|
Tzroya A, Duadi H, Fixler D. Optical Method for Detection and Classification of Heavy Metal Contaminants in Water Using Iso-pathlength Point Characterization. ACS Omega 2024; 9:6986-6993. [PMID: 38371777 PMCID: PMC10870376 DOI: 10.1021/acsomega.3c08792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 01/13/2024] [Accepted: 01/16/2024] [Indexed: 02/20/2024]
Abstract
Water pollution caused by hazardous substances, particularly heavy metal (HM) ions, poses a threat to human health and the environment. Traditional methods for measuring HM in water are expensive and time-consuming and require extensive sample preparation. Therefore, developing robust, simple, and sensitive techniques for the detection and classification of HM is needed. We propose an optical approach that exploits the full scattering profile, meaning the angular intensity distribution, and utilizes the iso-pathlength (IPL) point. This point appears where the intensity is constant for different scattering coefficients, while the absorption coefficient is set. The absorption does not affect the IPL point position, it only reduces its intensity. In this paper, we explore the wavelength influence on the IPL point both in Monte Carlo simulations and experimentally. Next, we present the characterization of ferric chloride (FeCl2) by this phenomenon. Eventually, we exhibit the detection of FeCl2 and intralipid mixed in concentrations of 50-100 and 20-30 ppm, respectively. These findings endorse the idea that the IPL point is an intrinsic parameter of a system serving as an absolute calibration point. The method provides an efficient way of differentiating contamination in water. Its characterization technique is easy, precise, and versatile making it preferable for water monitoring.
Collapse
Affiliation(s)
- Alon Tzroya
- The Faculty of Engineering
and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290000, Israel
| | - Hamootal Duadi
- The Faculty of Engineering
and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290000, Israel
| | - Dror Fixler
- The Faculty of Engineering
and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290000, Israel
| |
Collapse
|
3
|
Pawar S, Duadi H, Friedman Gohas M, Cohen Y, Fixler D. Bioimaging based on Poly(ethylenimine)-Coated Carbon Dots and Gold Nanoparticles for pH Sensing and Metal Enhanced Fluorescence. ACS Appl Bio Mater 2023; 6:4935-4943. [PMID: 37870948 DOI: 10.1021/acsabm.3c00639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
When exposed to specific light wavelengths, carbon dots (CDs), which tend to be fluorescent, can emit colorful light. It provides them with a lot of adaptability for different applications including bioimaging, optoelectronics, and even environmental sensing. Poly(ethylenimine) (PEI) coated carbon dots (PEI-CDs) with a long emission wavelength were synthesized via the hydrothermal method. The resultant CDs show strong fluorescence with quantum yield up to 20.2%. The PEI-CDs exist with distinct pH-sensitive features with pH values in the range of 2-14. The optical characteristics of CDs are pH-responsive due to the presence of different amine groups on PEI, which is a functional polycationic polymer. One of the most widely employed nanoparticles for improving the fluorescence plasmonic characteristics of a nanocomposite is gold. Gold nanoparticles were coupled with PEI-CDs in this assay by using the EDC-NHS coupling to increase the photoluminescence property of the PEI-CDs by using the metal-enhanced fluorescence approach. In the presence of gold nanoparticles, the fluorescence is enhanced 5-6 times. The likely mechanism in our investigation was primarily derived from enhancement of the intrinsic radiative decay rate rather than the local electric field impact. Moreover, PEI-CDs can be used as a bioimaging agent, as these molecules are nontoxic to the cells, and the positively charged PEI-CDs have the potential for nuclear targeting, allowing for electrostatic contact with DNA in the nucleus. This finding will expand the application that the PEI-CDs can be used in the future for targeted imaging applications.
Collapse
Affiliation(s)
- Shweta Pawar
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Hamootal Duadi
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Moran Friedman Gohas
- Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv 6997801, Israel
- IVF Unit, Chaim Sheba Medical Centre, Tel-Hashomer, Ramat-Gan 52621, Israel
| | - Yoram Cohen
- Sackler Faculty of Medicine, Tel-Aviv University, Tel Aviv 6997801, Israel
- IVF Unit, Chaim Sheba Medical Centre, Tel-Hashomer, Ramat-Gan 52621, Israel
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
4
|
Yahav G, Pawar S, Lipovsky A, Gupta A, Gedanken A, Duadi H, Fixler D. Probing Polarity and pH Sensitivity of Carbon Dots in Escherichia coli through Time-Resolved Fluorescence Analyses. Nanomaterials (Basel) 2023; 13:2068. [PMID: 37513079 PMCID: PMC10384995 DOI: 10.3390/nano13142068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 07/09/2023] [Accepted: 07/12/2023] [Indexed: 07/30/2023]
Abstract
Intracellular monitoring of pH and polarity is crucial for understanding cellular processes and functions. This study employed pH- and polarity-sensitive nanomaterials such as carbon dots (CDs) for the intracellular sensing of pH, polarity, and viscosity using integrated time-resolved fluorescence anisotropy (FA) imaging (TR-FAIM) and fluorescence lifetime (FLT) imaging microscopy (FLIM), thereby enabling comprehensive characterization. The functional groups on the surface of CDs exhibit sensitivity to changes in the microenvironment, leading to variations in fluorescence intensity (FI) and FLT according to pH and polarity. The FLT of CDs in aqueous solution changed gradually from 6.38 ± 0.05 ns to 8.03 ± 0.21 ns within a pH range of 2-8. Interestingly, a complex relationship of FI and FLT was observed during measurements of CDs with decreasing polarity. However, the FA and rotational correlation time (θ) increased from 0.062 ± 0.019 to 0.112 ± 0.023 and from 0.49 ± 0.03 ns to 2.01 ± 0.27 ns, respectively. This increase in FA and θ was attributed to the higher viscosity accompanying the decrease in polarity. Furthermore, CDs were found to bind to three locations in Escherichia coli: the cell wall, inner membrane, and cytoplasm, enabling intracellular characterization using FI and FA decay imaging. FLT provided insights into cytoplasmic pH (7.67 ± 0.48), which agreed with previous works, as well as the decrease in polarity in the cell wall and inner membrane. The CD aggregation was suspected in certain areas based on FA, and the θ provided information on cytoplasmic heterogeneity due to the aggregation and/or interactions with biomolecules. The combined TR-FAIM/FLIM system allowed for simultaneous monitoring of pH and polarity changes through FLIM and viscosity variations through TR-FAIM.
Collapse
Affiliation(s)
- Gilad Yahav
- Institute of Nanotechnology and Advanced Materials, Faculty of Engineering, Bar-Ilan University, Ramat Gan 52900, Israel
| | - Shweta Pawar
- Institute of Nanotechnology and Advanced Materials, Faculty of Engineering, Bar-Ilan University, Ramat Gan 52900, Israel
| | - Anat Lipovsky
- Institute of Nanotechnology and Advanced Materials, Faculty of Engineering, Bar-Ilan University, Ramat Gan 52900, Israel
| | - Akanksha Gupta
- Institute of Nanotechnology and Advanced Materials, Department of Chemistry, Bar-Ilan University, Ramat Gan 52900, Israel
| | - Aharon Gedanken
- Institute of Nanotechnology and Advanced Materials, Department of Chemistry, Bar-Ilan University, Ramat Gan 52900, Israel
| | - Hamootal Duadi
- Institute of Nanotechnology and Advanced Materials, Faculty of Engineering, Bar-Ilan University, Ramat Gan 52900, Israel
| | - Dror Fixler
- Institute of Nanotechnology and Advanced Materials, Faculty of Engineering, Bar-Ilan University, Ramat Gan 52900, Israel
| |
Collapse
|
5
|
Tzroya A, Erblich S, Duadi H, Fixler D. Detecting Contaminants in Water Based on Full Scattering Profiles within the Single Scattering Regime. ACS Omega 2023; 8:23733-23738. [PMID: 37426274 PMCID: PMC10323954 DOI: 10.1021/acsomega.3c01977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 06/06/2023] [Indexed: 07/11/2023]
Abstract
Clean water is essential for maintaining human health. To ensure clean water, it is important to use sensitive detection methods that can identify contaminants in real time. Most techniques do not rely on optical properties and require calibrating the system for each level of contamination. Therefore, we suggest a new technique to measure water contamination using the full scattering profile, which is the angular intensity distribution. From this, we extracted the iso-pathlength (IPL) point which minimizes the effects of scattering. The IPL point is an angle where the intensity values remain constant for different scattering coefficients while the absorption coefficient is set. The absorption coefficient does not affect the IPL point but only attenuates its intensity. In this paper, we show the appearance of the IPL in single scattering regimes for small concentrations of Intralipid. We extracted a unique point for each sample diameter wherein light intensity remained constant. The results describe a linear dependency between the angular position of the IPL point and the sample diameter. In addition, we show that the IPL point separates the absorption from the scattering, which allows the absorption coefficient to be extracted. Eventually, we present how we used the IPL point to detect the contamination levels of Intralipid and India ink in concentrations of 30-46 and 0-4 ppm, respectively. These findings suggest that the IPL point is an intrinsic parameter of a system that can be used as an absolute calibration point. This method provides a new and efficient way of measuring and differentiating between various types of contaminants in water.
Collapse
Affiliation(s)
- Alon Tzroya
- The
Faculty of Engineering and the Institute of Nanotechnology and Advanced
Materials, Bar Ilan University, Ramat Gan 5290000, Israel
| | - Shoshana Erblich
- School
of Engineering, Rutgers University, New Brunswick, New Jersey 08901-8554, United
States
| | - Hamootal Duadi
- The
Faculty of Engineering and the Institute of Nanotechnology and Advanced
Materials, Bar Ilan University, Ramat Gan 5290000, Israel
| | - Dror Fixler
- The
Faculty of Engineering and the Institute of Nanotechnology and Advanced
Materials, Bar Ilan University, Ramat Gan 5290000, Israel
| |
Collapse
|
6
|
Weber Y, Duadi H, Rudraiah PS, Yariv I, Yahav G, Fixler D, Ankri R. Fluorescence attenuated by a thick scattering medium: Theory, simulations and experiments. J Biophotonics 2023; 16:e202300045. [PMID: 36883623 DOI: 10.1002/jbio.202300045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 03/01/2023] [Accepted: 03/04/2023] [Indexed: 06/07/2023]
Abstract
Fluorescence-based imaging has an enormous impact on our understanding of biological systems. However, in vivo fluorescence imaging is greatly influenced by tissue scattering. A better understanding of this dependence can improve the potential of noninvasive in vivo fluorescence imaging. In this article, we present a diffusion model, based on an existing master-slave model, of isotropic point sources imbedded in a scattering slab, representing fluorophores within a tissue. The model was compared with Monte Carlo simulations and measurements of a fluorescent slide measured through tissue-like phantoms with different reduced scattering coefficients (0.5-2.5 mm-1 ) and thicknesses (0.5-5 mm). Results show a good correlation between our suggested theory, simulations and experiments; while the fluorescence intensity decays as the slab's scattering and thickness increase, the decay rate decreases as the reduced scattering coefficient increases in a counterintuitive manner, suggesting fewer fluorescence artifacts from deep within the tissue in highly scattering media.
Collapse
Affiliation(s)
- Yitzchak Weber
- The Department of Physics, Ariel University, Ariel, 4007000, Israel
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Hamootal Duadi
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Pavitra Sokke Rudraiah
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Inbar Yariv
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Gilad Yahav
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Rinat Ankri
- The Department of Physics, Ariel University, Ariel, 4007000, Israel
| |
Collapse
|
7
|
Yahav G, Pawar S, Weber Y, Atuar B, Duadi H, Fixler D. Imaging the rotational mobility of carbon dot-gold nanoparticle conjugates using frequency domain wide-field time-resolved fluorescence anisotropy. J Biomed Opt 2023; 28:056001. [PMID: 37229274 PMCID: PMC10203731 DOI: 10.1117/1.jbo.28.5.056001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 04/28/2023] [Accepted: 05/08/2023] [Indexed: 05/27/2023]
Abstract
Significance Wide-field measurements of time-resolved fluorescence anisotropy (TR-FA) provide pixel-by-pixel information about the rotational mobility of fluorophores, reflecting changes in the local microviscosity and other factors influencing the fluorophore's diffusional motion. These features offer promising potential in many research fields, including cellular imaging and biochemical sensing, as demonstrated by previous works. Nevertheless, θ imaging is still rarely investigated in general and in carbon dots (CDs) in particular. Aim To extend existing frequency domain (FD) fluorescence lifetime (FLT) imaging microscopy (FLIM) to FD TR-FA imaging (TR-FAIM), which produces visual maps of the FLT and θ, together with the steady-state images of fluorescence intensity (FI) and FA (r). Approach The proof of concept of the combined FD FLIM/ FD TR-FAIM was validated on seven fluorescein solutions with increasing viscosities and was applied for comprehensive study of two types of CD-gold nano conjugates. Results The FLT of fluorescein samples was found to decrease from 4.01±0.01 to 3.56±0.02 ns, whereas both r and θ were significantly increased from 0.053±0.012 to 0.252±0.003 and 0.15±0.05 to 11.25±1.87 ns, respectively. In addition, the attachment of gold to the two CDs resulted in an increase in the FI due to metal-enhanced fluorescence. Moreover, it resulted in an increase of r from 0.100±0.011 to 0.150±0.013 and θ from 0.98±0.13 to 1.65±0.20 ns for the first CDs and from 0.280±0.008 to 0.310±0.004 and 5.55±1.08 to 7.95±0.97 ns for the second CDs. These trends are due to the size increase of the CDs-gold compared to CDs alone. The FLT presented relatively modest changes in CDs. Conclusions Through the combined FD FLIM/ FD TR-FAIM, a large variety of information can be probed (FI, FLT, r, and θ). Nevertheless, θ was the most beneficial, either by probing the spatial changes in viscosity or by evident variations in the peak and full width half maximum.
Collapse
Affiliation(s)
- Gilad Yahav
- Bar Ilan University, The Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Shweta Pawar
- Bar Ilan University, The Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Yitzchak Weber
- Bar Ilan University, The Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Bar Atuar
- Bar Ilan University, The Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Hamootal Duadi
- Bar Ilan University, The Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Dror Fixler
- Bar Ilan University, The Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| |
Collapse
|
8
|
Dudchenko N, Pawar S, Perelshtein I, Fixler D. Magnetite-Based Biosensors and Molecular Logic Gates: From Magnetite Synthesis to Application. Biosensors (Basel) 2023; 13:304. [PMID: 36979516 PMCID: PMC10046048 DOI: 10.3390/bios13030304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 02/19/2023] [Accepted: 02/20/2023] [Indexed: 06/18/2023]
Abstract
In the last few decades, point-of-care (POC) sensors have become increasingly important in the detection of various targets for the early diagnostics and treatment of diseases. Diverse nanomaterials are used as building blocks for the development of smart biosensors and magnetite nanoparticles (MNPs) are among them. The intrinsic properties of MNPs, such as their large surface area, chemical stability, ease of functionalization, high saturation magnetization, and more, mean they have great potential for use in biosensors. Moreover, the unique characteristics of MNPs, such as their response to external magnetic fields, allow them to be easily manipulated (concentrated and redispersed) in fluidic media. As they are functionalized with biomolecules, MNPs bear high sensitivity and selectivity towards the detection of target biomolecules, which means they are advantageous in biosensor development and lead to a more sensitive, rapid, and accurate identification and quantification of target analytes. Due to the abovementioned properties of functionalized MNPs and their unique magnetic characteristics, they could be employed in the creation of new POC devices, molecular logic gates, and new biomolecular-based biocomputing interfaces, which would build on new ideas and principles. The current review outlines the synthesis, surface coverage, and functionalization of MNPs, as well as recent advancements in magnetite-based biosensors for POC diagnostics and some perspectives in molecular logic, and it also contains some of our own results regarding the topic, which include synthetic MNPs, their application for sample preparation, and the design of fluorescent-based molecular logic gates.
Collapse
Affiliation(s)
- Nataliia Dudchenko
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Shweta Pawar
- Faculty of Engineering and Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Ilana Perelshtein
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Dror Fixler
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
9
|
Pawar S, Duadi H, Fixler D. Recent Advances in the Spintronic Application of Carbon-Based Nanomaterials. Nanomaterials (Basel) 2023; 13:598. [PMID: 36770559 PMCID: PMC9919822 DOI: 10.3390/nano13030598] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 01/29/2023] [Accepted: 01/30/2023] [Indexed: 06/18/2023]
Abstract
The term "carbon-based spintronics" mostly refers to the spin applications in carbon materials such as graphene, fullerene, carbon nitride, and carbon nanotubes. Carbon-based spintronics and their devices have undergone extraordinary development recently. The causes of spin relaxation and the characteristics of spin transport in carbon materials, namely for graphene and carbon nanotubes, have been the subject of several theoretical and experimental studies. This article gives a summary of the present state of research and technological advancements for spintronic applications in carbon-based materials. We discuss the benefits and challenges of several spin-enabled, carbon-based applications. The advantages include the fact that they are significantly less volatile than charge-based electronics. The challenge is in being able to scale up to mass production.
Collapse
Affiliation(s)
- Shweta Pawar
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Hamootal Duadi
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
10
|
Azrad-Leibovich T, Zahavi A, Gohas MF, Brookman M, Barinfeld O, Muhsinoglu O, Michowiz S, Fixler D, Goldenberg-Cohen N. Characterization of Diabetic Retinopathy in Two Mouse Models and Response to a Single Injection of Anti-Vascular Endothelial Growth Factor. Int J Mol Sci 2022; 24:ijms24010324. [PMID: 36613769 PMCID: PMC9820807 DOI: 10.3390/ijms24010324] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 12/06/2022] [Accepted: 12/20/2022] [Indexed: 12/28/2022] Open
Abstract
In this study, we characterized diabetic retinopathy in two mouse models and the response to anti-vascular endothelial growth factor (VEGF) injection. The study was conducted in 58 transgenic, non-obese diabetic (NOD) mice with spontaneous type 1 diabetes (n = 30, DMT1-NOD) or chemically induced (n = 28, streptozotocin, STZ-NOD) type 1 diabetes and 20 transgenic db/db mice with type 2 diabetes (DMT2-db/db); 30 NOD and 8 wild-type mice served as controls. Mice were examined at 21 days for vasculopathy, retinal thickness, and expression of genes involved in oxidative stress, angiogenesis, gliosis, and diabetes. The right eye was histologically examined one week after injection of bevacizumab, ranibizumab, saline, or no treatment. Flat mounts revealed microaneurysms and one apparent area of tufts of neovascularization in the diabetic retina. Immunostaining revealed activation of Müller glia and prominent Müller cells. Mean retinal thickness was greater in diabetic mice. RAGE increased and GFAP decreased in DMT1-NOD mice; GFAP and SOX-9 mildly increased in db/db mice. Anti-VEGF treatment led to reduced retinal thickness. Retinas showed vasculopathy and edema in DMT1-NOD and DMT2-db/db mice and activation of Müller glia in DMT1-NOD mice, with some response to anti-VEGF treatment. Given the similarity of diabetic retinopathy in mice and humans, comparisons of type 1 and type 2 diabetic mouse models may assist in the development of new treatment modalities.
Collapse
Affiliation(s)
- Tamar Azrad-Leibovich
- Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 4941492, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Alon Zahavi
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Department of Ophthalmology, Rabin Medical Center—Beilinson Hospital, Petach Tikva 4941492, Israel
- Laboratory of Eye Research, Felsenstein Medical Research Center, Petach Tikva 4941492, Israel
| | - Moran Friedman Gohas
- Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 4941492, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Myles Brookman
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Orit Barinfeld
- Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 4941492, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Orkun Muhsinoglu
- Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 4941492, Israel
| | - Shalom Michowiz
- Department of Neurosurgery, Rabin Medical Center—Beilinson Hospital, Petach Tikva 4941492, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechonology and Advanced Materials, Bar Ilan University, Ramat Gan 5200100, Israel
| | - Nitza Goldenberg-Cohen
- Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 4941492, Israel
- Department of Ophthalmology, Bnai Zion Medical Center of Israel, Haifa 3339419, Israel
- Bruce and Ruth Rappaport Faculty of Medicine, Israel Institute of Technology—Technion, Haifa 3200003, Israel
- Correspondence: ; Tel.: +97-(24)-8359554
| |
Collapse
|
11
|
Shapira C, Itshak D, Duadi H, Harel Y, Atkins A, Lipovsky A, Lavi R, Lellouche JP, Fixler D. Noninvasive Nanodiamond Skin Permeation Profiling Using a Phase Analysis Method: Ex Vivo Experiments. ACS Nano 2022; 16:15760-15769. [PMID: 36037067 DOI: 10.1021/acsnano.2c03613] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Carbon-based nanoparticles (NPs) are widely used in nanotechnology. Among them, nanodiamonds (NDs) are suitable for biotechnology and are especially interesting for skin delivery and topical treatments. However, noninvasive detection of NDs within the different skin layers or analyzing their penetration ability is complicated due to the turbid nature of the tissue. The iterative multiplane optical properties extraction (IMOPE) technique detects differences in the optical properties of the measured item by a phase-image analysis method. The phase image is reconstructed by the multiplane Gerchberg-Saxton algorithm. This technique, traditionally, detects differences in the reduced scattering coefficients. Here, however, due to the actual size of the NDs, the IMOPE technique's detection relies on absorption analysis rather than relying on scattering events. In this paper, we use the IMOPE technique to detect the presence of the NDs within tissue-like phantoms. In addition, we perform ex vivo pigskin experiments to estimate the penetration of the NDs to the different skin layers and show that their presence reduces at deeper layers. The significance signal of the NDs within the epidermis, dermis, and fat layers gradually reduces, with t test significance values that are smaller than 10-4, 10-3, and 10-2, respectively. The IMOPE results are corroborated by TEM results and Franz-cell experiments. These results confirm that the IMOPE profiled the skin-permeation of the NDs noninvasively.
Collapse
Affiliation(s)
- Channa Shapira
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Daniel Itshak
- Department of Chemistry, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Hamootal Duadi
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Yifat Harel
- Department of Chemistry, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Ayelet Atkins
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Anat Lipovsky
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Ronit Lavi
- Department of Chemistry, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Jean Paul Lellouche
- Department of Chemistry, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Dror Fixler
- Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
12
|
Girshevitz O, Cohen-Sinai N, Zahavi A, Vardizer Y, Fixler D, Goldenberg-Cohen N. Trace Elements in Tears: Comparison of Rural and Urban Populations Using Particle Induced X-ray Emission. J Pers Med 2022; 12:jpm12101633. [PMID: 36294772 PMCID: PMC9605629 DOI: 10.3390/jpm12101633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/22/2022] [Accepted: 09/29/2022] [Indexed: 11/06/2022] Open
Abstract
We aimed to evaluate the types and concentrations of trace elements in tears of individuals living in urban and rural environments using particle induced X-ray emission (PIXE) and the possible association with exposure to air pollution and suggest a novel method for tear-based biomonitoring studies. This cross-sectional pilot study comprised 42 healthy subjects, 28 living in a rural area and 14 in an industrial city. Tears were collected with Schirmer paper and characterized by PIXE. Trace element concentrations from both eyes were averaged together with environmental pollution data. Main outcome measures were between-group differences in types and concentrations of trace elements in tears and comparison to environmental data. The rural group included 12/28 men, mean age 45.2 ± 14.8 years. The urban group consisted of 11/14 men of mean age 27 ± 5.9 years. Six rural and all urban were active smokers. Air pollution data showed more toxic elements in the rural environment. On PIXE analysis, chlorine, sodium, and potassium were found in similar concentrations in all samples. Normalizing to chlorine yielded higher values of aluminum, iron, copper, and titanium in the rural group; aluminum was found only in the rural group. The higher levels of certain trace elements in the rural group may, in part, be a consequence of exposure to specific environmental conditions. No direct association was found with air pollution data. PIXE is useful to analyze trace elements in tears, which might serve as a marker for individual exposure to environmental pollutants in biomonitoring studies.
Collapse
Affiliation(s)
- Olga Girshevitz
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel
| | - Noa Cohen-Sinai
- Department of Ophthalmology, Bnai-Zion Medical Center, Haifa 339419, Israel
| | - Alon Zahavi
- Department of Ophthalmology, Rabin Medical Center—Beilinson Hospital, Petach Tikva 4941492, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Yoav Vardizer
- Department of Ophthalmology, Bnai-Zion Medical Center, Haifa 339419, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan 5290002, Israel
| | - Nitza Goldenberg-Cohen
- Department of Ophthalmology, Bnai-Zion Medical Center, Haifa 339419, Israel
- The Krieger Eye Research Laboratory, Bruce and Ruth Rapaport Faculty of Medicine, Technion, Israel Institute of Technology, Haifa 3200003, Israel
- Correspondence: ; Tel.: +972-4-8359554
| |
Collapse
|
13
|
Pawar S, Duadi H, Fleger Y, Fixler D. Design and Use of a Gold Nanoparticle-Carbon Dot Hybrid for a FLIM-Based IMPLICATION Nano Logic Gate. ACS Omega 2022; 7:22818-22824. [PMID: 35811911 PMCID: PMC9260748 DOI: 10.1021/acsomega.2c02463] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 06/08/2022] [Indexed: 06/15/2023]
Abstract
The interest in nanomaterials resides in the fact that they can be used to create smaller, faster, and more portable systems. Nanotechnology is already transforming health care. Nanoparticles are being used by scientists to target malignancies, improve drug delivery systems, and improve medical imaging. Integration of biomolecular logic gates with nanostructures has opened new paths in illness detection and therapy that need precise control of complicated components. Most studies have used fluorescence intensity techniques to implement the logic function. Its drawbacks, mainly when working with nanoparticles in intracellular media, include fluctuations in excitation power, fluorophore concentration dependence, and interference from cell autofluorescence. We suggest using fluorescence lifetime imaging microscopy (FLIM) in order to circumvent these constraints. Designing a nanohybrid composed of gold nanoparticles (AuNPs) and red-emitting carbon dots (CDs) can be used to develop a FLIM-based logic gate that can respond to multiple input parameters. Our findings indicate a nanohybrid that can serve as a nano-computer to receive and integrate chemical and biochemical stimuli and produce a definitive output measured by FLIM. This can open a new research avenue for enhanced diagnostics and therapy that require complicated factor handling and precise control. The AuNPs are conjugated to CDs' surfaces through a strong covalent linkage. The AuNP-CD nanohybrid shows fluorescence lifetime (FLT) quenching of pristine CDs after conjugation to AuNPs. The FLT was reduced from 3.61 ± 0.037 to 2.48 ± 0.040 ns. This quenched FLT can be recovered back by using trypsin as a recovering agent, giving us a reversible logic output. The FLT was recovered to 3.01 ± 0.01 ns after trypsin addition. This "on-off-on" response can be used to construct the IMPLICATION logic gate.
Collapse
Affiliation(s)
- Shweta Pawar
- Faculty
of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- Bar-Ilan
Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Hamootal Duadi
- Faculty
of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- Bar-Ilan
Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Yafit Fleger
- Bar-Ilan
Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| | - Dror Fixler
- Faculty
of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel
- Bar-Ilan
Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
14
|
Sadhanala HK, Pagidi S, Yadav S, Beiderman M, Grinberg I, Fixler D, Gedanken A. Boron‐doped Carbon Dots with Surface Oxygen Functional Groups as a Highly Sensitive and Label‐free Photoluminescence Probe for the Enhanced Detection of Mg
2+
Ions. ChemistrySelect 2022. [DOI: 10.1002/slct.202201261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
| | - Sudhakar Pagidi
- Department of Chemistry Bar-Ilan University Ramat-Gan 5290002 Israel
| | - Suhas Yadav
- Department of Chemistry Bar-Ilan University Ramat-Gan 5290002 Israel
| | | | - Ilya Grinberg
- Department of Chemistry Bar-Ilan University Ramat-Gan 5290002 Israel
| | - Dror Fixler
- Faculty of Engineering Bar-Ilan University Ramat Gan 5290002 Israel
| | - Aharon Gedanken
- Department of Chemistry Bar-Ilan University Ramat-Gan 5290002 Israel
| |
Collapse
|
15
|
Lubart R, Yariv I, Fixler D, Lipovsky A. A Novel Facial Cream Based on Skin-penetrable Fibrillar Collagen Microparticles. J Clin Aesthet Dermatol 2022; 15:59-64. [PMID: 35642230 PMCID: PMC9122277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
BACKGROUND Collagen protein plays a notable role maintaining firm skin. Topical creams containing collagen fibers are widely available, but their usefulness is questionable due to limited skin penetration. When applied in a cream, collagen does not penetrate the skin leaving the skin structure unaffected. OBJECTIVE We formulated micronized collagen in a cream base. Using human skin samples, we sought to investigate the ability of the micronized collagen cream to penetrate human skin. METHODS Particle sizes of micronized marine collagen were evaluated using electron microscopy. Optical profilometry was conducted to evaluate skin topography and roughness. The antioxidant activity of the collagen was evaluated using the electron paramagnetic resonance technique by measuring the changes in free radical production. Collagen penetration depth in human skin samples was monitored using a non-invasive optical technique known as iterative multiplane optical property extraction, which works based on the detection of laser light phase changes following the presence of collagen particles in deep skin layers. RESULTS According to the electron microscopy, collagen particles were found to be of various sizes, the smallest being about 120nm in diameter. Skin topography measurements revealed that the treated collagen cream increased skin smoothness of the samples. Our results derived from the iterative multiplane optical property extraction indicated that micronized collagen in a cream base penetrates both the stratum corneum and the deep epidermal layers toward the dermis. CONCLUSION Our investigation suggests that the collagen in the studied cream formulation was able to penetrate the stratum coreum and deep epidermal layers in human skin samples.
Collapse
Affiliation(s)
- Rachel Lubart
- Dr. Lubart is with the Chemistry Department and Physics of Bar Ilan University, Ramat Gan, Israel
| | - Inbar Yariv
- Drs. Yariv and Fixler are with the Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials at Bar Ilan University, Ramat Gan, Israel
| | - Dror Fixler
- Drs. Yariv and Fixler are with the Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials at Bar Ilan University, Ramat Gan, Israel
| | - Anat Lipovsky
- Dr. Lipovsky is with Hava Zingboim Ltd., Ramat-Gan, Israel
| |
Collapse
|
16
|
Dudchenko N, Pawar S, Perelshtein I, Fixler D. Magnetite Nanoparticles: Synthesis and Applications in Optics and Nanophotonics. Materials (Basel) 2022; 15:2601. [PMID: 35407934 PMCID: PMC9000335 DOI: 10.3390/ma15072601] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Revised: 03/24/2022] [Accepted: 03/29/2022] [Indexed: 02/01/2023]
Abstract
Magnetite nanoparticles with different surface coverages are of great interest for many applications due to their intrinsic magnetic properties, nanometer size, and definite surface morphology. Magnetite nanoparticles are widely used for different medical-biological applications while their usage in optics is not as widespread. In recent years, nanomagnetite suspensions, so-called magnetic ferrofluids, are applied in optics due to their magneto-optical properties. This review gives an overview of nanomagnetite synthesis and its properties. In addition, the preparation and application of magnetic nanofluids in optics, nanophotonics, and magnetic imaging are described.
Collapse
Affiliation(s)
- Nataliia Dudchenko
- Department of Chemistry, Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel; (N.D.); (I.P.)
| | - Shweta Pawar
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Faculty of Engineering, Bar Ilan University, Ramat Gan 5290002, Israel;
| | - Ilana Perelshtein
- Department of Chemistry, Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel; (N.D.); (I.P.)
| | - Dror Fixler
- Department of Chemistry, Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel; (N.D.); (I.P.)
| |
Collapse
|
17
|
Rudraiah PS, Duadi H, Fixler D. Diffused reflectance measurements to detect tattoo ink location in skin using the crossover point. J Biophotonics 2022; 15:e202200003. [PMID: 35067001 DOI: 10.1002/jbio.202200003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 01/20/2022] [Accepted: 01/21/2022] [Indexed: 06/14/2023]
Abstract
Tattoos are highly trendy in western culture, but many people regret their tattoos for many reasons. It is essential to be aware of the ink location in advance to reduce the long and short-term side effects. In this study, diffuse reflectance (DR) experiments were conducted on two-layer (2L) tissue-mimicking phantoms, where ink was sandwiched between the layers. An appreciable difference in the DR profile was found between the 2L phantom with and without the tattoo ink using the crossover point (Cp) method. Our technique was applied to ex vivo porcine skin. A point of intersection was found, between the skin and the tattooed skin. In the shorter wavelengths (500-600 nm), a distinguishable 2L behavior was found, and in longer wavelengths (600-850 nm), a single layer behavior was found between the tattooed skin before and after the intersection. In biological tissue, this Cp indeed finds the tattoo ink without harm to the surrounding skin.
Collapse
Affiliation(s)
- Pavitra Sokke Rudraiah
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Hamootal Duadi
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| |
Collapse
|
18
|
Yahav G, Weber Y, Duadi H, Pawar S, Fixler D. Classification of fluorescent anisotropy decay based on the distance approach in the frequency domain. Opt Express 2022; 30:6176-6192. [PMID: 35209559 DOI: 10.1364/oe.453108] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 02/01/2022] [Indexed: 06/14/2023]
Abstract
Frequency-domain (FD) fluorometry is a widely utilized tool to probe unique features of complex biological structures, which may serve medical diagnostic purposes. The conventional data analysis approaches used today to extract the fluorescence intensity or fluorescence anisotropy (FA) decay data suffer from several drawbacks and are inherently limited by the characteristics and complexity of the decay models. This paper presents the squared distance (D2) technique, which categorized samples based on the direct frequency response data (FRD) of the FA decay. As such, it improves the classification ability of the FD measurements of the FA decay as it avoids any distortion that results from the challenged translation into time domain data. This paper discusses the potential use of the D2 approach to classify biological systems. Mathematical formulation of D2 technique adjusted to the FRD of the FA decay is described. In addition, it validates the D2 approach using 2 simulated data sets of 6 groups with similar widely and closely spaced FA decay data as well as in experimental data of 4 samples of a fluorophore-solvent (fluorescein-glycerol) system. In the simulations, the classification accuracy was above 95% for all 6 groups. In the experimental data, the classification accuracy was 100%. The D2 approach can help classify samples whose FA decay data are difficult to extract making FA in the FD a realistic diagnostic tool. The D2 approach offers an advanced method for sorting biological samples with differences beyond the practical temporal resolution limit in a reliable and efficient manner based on the FRD of their time-resolved fluorescence measurements thereby achieving better diagnostic quality in a shorter time.
Collapse
|
19
|
Beiderman M, Ashkenazy A, Segal E, Motiei M, Salomon A, Sadan T, Fixler D, Popovtzer R. Optimization of Gold Nanorod Features for the Enhanced Performance of Plasmonic Nanocavity Arrays. ACS Omega 2021; 6:29071-29077. [PMID: 34746596 PMCID: PMC8567385 DOI: 10.1021/acsomega.1c04301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 09/22/2021] [Indexed: 06/13/2023]
Abstract
Nanoplasmonic biosensors incorporating noble metal nanocavity arrays are widely used for the detection of various biomarkers. Gold nanorods (GNRs) have unique properties that can enhance spectroscopic detection capabilities of such nanocavity-based biosensors. However, the contribution of the physical properties of multiple GNRs to resonance enhancement of gold nanocavity arrays requires further characterization and elucidation. In this work, we study how GNR aspect ratio (AR) and surface area (SA) modify the plasmonic resonance spectrum of a gold triangular nanocavity array by both simulations and experiments. The finite integration technique (FIT) simulated the extinction spectrum of the gold nanocavity array with 300 nm periodicity onto which the GNRs of different ARs and SAs are placed. Simulations showed that matching of the GNRs longitudinal peak, which is affected by AR, to the nanocavity array's spectrum minima can optimize signal suppression and shifting. Moreover, increasing SA of the matched GNRs increased the spectral variations of the array. Experiments confirmed that GNRs conjugated to a gold triangular nanocavity array of 300 nm periodicity caused spectrum suppression and redshift. Our findings demonstrate that tailoring of the GNR AR and SA parameters to nanoplasmonic arrays has the potential to greatly improve spectral variations for enhanced plasmonic biosensing.
Collapse
Affiliation(s)
- Marianna Beiderman
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Ariel Ashkenazy
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Elad Segal
- Department
of Chemistry, Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Menachem Motiei
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Adi Salomon
- Department
of Chemistry, Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Tamar Sadan
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Dror Fixler
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| | - Rachela Popovtzer
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel
| |
Collapse
|
20
|
Rudraiah PS, Duadi H, Fixler D. Bottom layer absorption coefficients extraction from two-layer phantoms based on crossover point in diffuse reflectance. J Biomed Opt 2021; 26:JBO-210253R. [PMID: 34850612 PMCID: PMC8630471 DOI: 10.1117/1.jbo.26.11.117001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 11/16/2021] [Indexed: 06/13/2023]
Abstract
SIGNIFICANCE Numerous optical imaging and spectroscopy techniques are used to study the tissue-optical properties; the majority of them are limited in information regarding the penetration depth. A simple, safe, easily applicable diagnostic technique is required to get deeper tissue information in a multilayer structure. AIM A fiber-based diffuse reflectance (DR) technique is used to extract and quantify the bottom layer absorption coefficients in two-layer (2L) tissue-mimicking solid phantoms. We determine the Indian black ink concentrations in a deep-hidden layer that is sandwiched between agar and silicone-based phantom layers. APPROACH A fiber-based DR experiment was performed to study the optical properties of the tissue at higher penetration depth, with different fiber core diameters and a constant numerical aperture (0.5 NA). The optimal core diameter of the fiber was chosen by measuring solid phantoms. In 2L phantoms, the thickness of the top layer was kept 5.5 mm with a constant absorption and reduced scattering coefficients (μa = 0.045 mm - 1 and μs ' = 2.622 mm - 1), whereas the absorption coefficients of the bottom layers were varied from 0.014 to 0.037 mm - 1 keeping the μs ' the same as the top layer. A unique crossover point (Cp) was found in the DR intensity profile against distance. We examined the slope before and after the Cp. These two slopes indicate the difference between the optical properties of the top and bottom layers. Our technique got further verification, as we successfully determined the Cp with different Indian black ink concentrations, placed at the junction between the agar and silicone-based phantom layers. RESULTS The DR measurements were applied to 2L phantoms. Two different slopes were found in 2L phantoms compared to the one-layer (optical properties equal to the top layer of 2L). We extracted the slopes before and after the Cp in the 2L phantoms. The calculated absorption coefficients before the Cp were 0.014 ± 0.0004, 0.022 ± 0.0003, 0.028 ± 0.0003, and 0.036 ± 0.0014 mm - 1, and the absorption coefficients after the Cp were 0.019 ± 0.0013, 0.013 ± 0.0004, 0.014 ± 0.0006, and 0.031 ± 0.0001 mm - 1, respectively. The calculated absorption coefficients before the Cp were in good agreement with the optical properties of the bottom layer. The calculated absorption coefficients after the Cp were not the same as the top layer. Our DR system successfully determines the crossover points 12.14 ± 0.11 and 11.73 ± 0.15 mm for 70% and 100% ink concentrations placed at the junction of the agar and silicone layers. CONCLUSIONS In a 2L tissue structure, the Cp depends on the absorption coefficients of top and bottom layers and the thickness of the top layer. With the help of the Cp and the absorption coefficients, one can determine the thickness of the top layer or vice versa. The slope value before the Cp in the DR profile allowed us to determine the absorption properties of the bottom layer instead of having the average behavior of the 2L phantom in the far detection range (11.0 to 17.0 mm).
Collapse
Affiliation(s)
- Pavitra S. Rudraiah
- Bar Ilan University, Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Hamootal Duadi
- Bar Ilan University, Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| | - Dror Fixler
- Bar Ilan University, Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Ramat Gan, Israel
| |
Collapse
|
21
|
Shapira C, Yariv I, Ankri R, Duadi H, Fixler D. Effect of optical magnification on the detection of the reduced scattering coefficient in the blue regime: theory and experiments. Opt Express 2021; 29:22228-22239. [PMID: 34265992 DOI: 10.1364/oe.431929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 06/21/2021] [Indexed: 06/13/2023]
Abstract
Imaging turbid media is range limited. In contrast, sensing the medium's optical properties is possible in larger depths using the iterative multi-plane optical properties extraction technique. It analyzes the reconstructed reemitted light phase image. The root mean square of the phase image yields two graphs with opposite behaviors that intersect at µ's,cp. These graphs enable the extraction of a certain range of the reduced scattering coefficient, µ's. Here, we aim to extend the range of µ's detection by optical magnification. We use a modified diffusion theory and show how µ's,cp shifts with the varying magnification. The theoretical results were tested experimentally, showing that the technique can be adapted to different ranges of µ's by changing the magnification.
Collapse
|
22
|
Sudri S, Allon I, El-Naaj IA, Fixler D, Hirshberg A. GOLD NANOPARTICLES REFLECTANCE DISCRIMINATE BENIGN FROM MALIGNANT SALIVARY GLAND NEOPLASMS. Oral Surg Oral Med Oral Pathol Oral Radiol 2021. [DOI: 10.1016/j.oooo.2021.03.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
23
|
Yariv I, Kannan S, Harel Y, Levy E, Duadi H, Lellouche JP, Michaeli S, Fixler D. Iterative optical technique for detecting anti-leishmania nanoparticles in mouse lesions. Biomed Opt Express 2021; 12:4496-4509. [PMID: 34457428 PMCID: PMC8367277 DOI: 10.1364/boe.425798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 06/16/2021] [Accepted: 06/17/2021] [Indexed: 06/13/2023]
Abstract
Nanoparticles (NPs) based drugs for topical administration are gaining interest in the biomedical world. However, a study tool of their penetration depth to the different tissue layers without additional markers or contrast agents is required in order to relieve safety concerns. While common diagnostic tools, e.g. X-ray, computed tomography or magnetic resonance imaging, can provide in vivo detection of the metallic NPs, their resolution cannot determine the exact penetration depth to the thin skin layers. In this work, we propose the noninvasive nanophotonics iterative multi-plane optical property extraction (IMOPE) technique for the novel iron-based NPs detection in leishmaniasis lesions. The optical properties of the different tissue layers: epidermis, dermis, subcutaneous fat and muscle, were examined before and after topical drug administration. The potential topical drug was detected in the epidermis (∼13µm) and dermis (∼160µm) layers in mice lesions at different stages of the disease (two or four weeks post infection). The lesion size influence on the detection was also observed, where in larger lesions the IMOPE senses a greater presence of the topical drug.
Collapse
Affiliation(s)
- Inbar Yariv
- Faculty of Engineering, Bar
Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
| | - Sriram Kannan
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
- The Mina and Everard Goodman Faculty of
Life Sciences, Bar Ilan University, Ramat
Gan 5290002, Israel
| | - Yifat Harel
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
- Department of Chemistry Faculty of Exact
Sciences, Bar Ilan University, Ramat Gan
5290002, Israel
| | - Esthy Levy
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
- Department of Chemistry Faculty of Exact
Sciences, Bar Ilan University, Ramat Gan
5290002, Israel
| | - Hamootal Duadi
- Faculty of Engineering, Bar
Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
| | - Jean-Paul Lellouche
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
- Department of Chemistry Faculty of Exact
Sciences, Bar Ilan University, Ramat Gan
5290002, Israel
| | - Shulamit Michaeli
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
- The Mina and Everard Goodman Faculty of
Life Sciences, Bar Ilan University, Ramat
Gan 5290002, Israel
| | - Dror Fixler
- Faculty of Engineering, Bar
Ilan University, Ramat Gan 5290002, Israel
- The Institute of Nanotechnology and
Advanced Materials, Bar Ilan University,
Ramat Gan 5290002, Israel
| |
Collapse
|
24
|
Sudri S, Duadi H, Altman F, Allon I, Ashkenazy A, Chakraborty R, Novikov I, Fixler D, Hirshberg A. Diffusion Reflection Method for Early Detection of Oral Squamous Cell Carcinoma Specifically Targeted by Circulating Gold-Nanorods Bio-Conjugated to Anti-Epidermal Growth Factor Receptor. Int J Nanomedicine 2021; 16:2237-2246. [PMID: 33762823 PMCID: PMC7982793 DOI: 10.2147/ijn.s300125] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Accepted: 02/13/2021] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Translation of nanomedical developments into clinical application is receiving an increasing interest. However, its use for oral squamous cell carcinoma (OSCC) diagnosis remains limited. We present an advanced nanophotonic method for oral cancer detection, based on diffusion reflection (DR) measurements of gold-nanorods bio-conjugated to anti-epidermal growth factor receptor (C-GNRs) specifically attached to OSCC cells. OBJECTIVE To investigate in a rat model of oral carcinogenesis the targeting potential of C-GNRs to OSCC by using the DR optical method. MATERIALS AND METHODS OSCC was induced by the carcinogen 4-nitroquinoline-N-oxide (4NQO). C-GNRs were introduced locally and systemically and DR measurements were recorded from the surface of the rat tongue following illumination with red laser beam. Rats were divided into experimental and control groups. The results were compared with the histologic diagnosis. RESULTS A total of 75 Wistar-derived rats were enrolled in the study. Local application did not reveal any statistical results. DR measurements following intravenous injection of C-GNRs revealed a significant increase in light absorption in rats with OSCC compare with rats without cancer (p<0.02, sensitivity 100%, specificity 89%). In addition, absorption of light increased significantly in cases of severe dysplasia and cancer (high risk) compared to rats without cancer and rats with mild dysplasia (low risk) (86% sensitivity and 89% specificity, AUC=0.79). CONCLUSION Combining nanotechnology and nanophotonics for in vivo diagnosis of OSCC serves as additional tier in the translation of advanced nanomedical developments into clinical applications. The presented method shows a promising potential of nanophotonics for oral cancer identification, and provides support for the use of C-GNRs as a selective drug delivery.
Collapse
Affiliation(s)
- Shiran Sudri
- Department of Oral Pathology and Oral Medicine, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Hamootal Duadi
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Florin Altman
- Department of Oral Pathology and Oral Medicine, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Irit Allon
- Institute of Pathology, Barzilai Medical Center, Ben Gurion University of the Negev, Beer Sheba, Israel
| | - Ariel Ashkenazy
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Ruchira Chakraborty
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Ilya Novikov
- Gertner Institute for Epidemiology and Health Policy Research, Ramat Gan, Israel
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Abraham Hirshberg
- Department of Oral Pathology and Oral Medicine, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
25
|
Pawar S, Duadi H, Fleger Y, Fixler D. Carbon Dots-Based Logic Gates. Nanomaterials (Basel) 2021; 11:232. [PMID: 33477327 PMCID: PMC7830989 DOI: 10.3390/nano11010232] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 01/12/2021] [Accepted: 01/14/2021] [Indexed: 12/11/2022]
Abstract
Carbon dots (CDs)-based logic gates are smart nanoprobes that can respond to various analytes such as metal cations, anions, amino acids, pesticides, antioxidants, etc. Most of these logic gates are based on fluorescence techniques because they are inexpensive, give an instant response, and highly sensitive. Computations based on molecular logic can lead to advancement in modern science. This review focuses on different logic functions based on the sensing abilities of CDs and their synthesis. We also discuss the sensing mechanism of these logic gates and bring different types of possible logic operations. This review envisions that CDs-based logic gates have a promising future in computing nanodevices. In addition, we cover the advancement in CDs-based logic gates with the focus of understanding the fundamentals of how CDs have the potential for performing various logic functions depending upon their different categories.
Collapse
Affiliation(s)
- Shweta Pawar
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel; (S.P.); (H.D.)
| | - Hamootal Duadi
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel; (S.P.); (H.D.)
| | - Yafit Fleger
- Bar-Ilan Institute of Nanotechnology & Advanced Materials (BINA), Bar Ilan University, Ramat Gan 5290002, Israel;
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel; (S.P.); (H.D.)
| |
Collapse
|
26
|
Chakraborty R, Leshem-Lev D, Kornowski R, Fixler D. The Scattering of Gold Nanorods Combined with Differential Uptake, Paving a New Detection Method for Macrophage Subtypes Using Flow Cytometery. Nano Lett 2020; 20:8360-8368. [PMID: 33063518 PMCID: PMC7662919 DOI: 10.1021/acs.nanolett.0c03525] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The strategy of identification for M1 and M2 macrophages both in vivo and in vitro would help to predict the health condition of the individual. Here, we introduced a solution to this problem with the advantage of both the phagocytic nature of macrophages and the scattering effect of gold nanorods (GNRs). The internalized GNRs, relating to their extent of intake, caused a conspicuous scattering profile at the red channel in flow cytometry, overruling the contribution of the cellular side scatters. This internalization is solely governed by the surface chemistry of GNRs. The PAH-GNRs showed maximum intake potency followed by Cit-, PSS-, and PEG-GNRs. On a substantial note, PAH-GNRs lead to differential uptake between M1 and M2 cells, with three times higher intake in M2 cells over M1. This is the first report of employing the scattering of unlabeled GNRs to discriminate M1 and M2 cell types using a flow cytometer.
Collapse
Affiliation(s)
- Ruchira Chakraborty
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel
| | - Dorit Leshem-Lev
- Cardiovascular
Biology Laboratories at the Felsenstein Medical Research Center and
the Cardiology Department, Rabin Medical
Center, Petah-Tikva 4941492, Israel
| | - Ran Kornowski
- Cardiovascular
Biology Laboratories at the Felsenstein Medical Research Center and
the Cardiology Department, Rabin Medical
Center, Petah-Tikva 4941492, Israel
| | - Dror Fixler
- Faculty
of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel
- . Tel: 972-3-531-7598
| |
Collapse
|
27
|
Feder I, Duadi H, Fixler D. Single wavelength measurements of absorption coefficients based on iso-pathlength point. Biomed Opt Express 2020; 11:5760-5771. [PMID: 33149984 PMCID: PMC7587282 DOI: 10.1364/boe.401591] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/03/2020] [Accepted: 09/03/2020] [Indexed: 05/31/2023]
Abstract
In optical sensing, to reveal the chemical composition of tissues, the main challenge is isolating absorption from scattering. Most techniques use multiple wavelengths, which adds an error due to the optical pathlength differences. We suggest using a unique measurement angle for cylindrical tissues, the iso-pathlength (IPL) point, which depends on tissue geometry only (specifically the effective radius). We present a method for absorption assessment from a single wavelength at multiple measurement angles. The IPL point presented similar optical pathlengths for different tissues, both in simulation and experiments, hence it is optimal. Finally, in vivo measurements validated our proposed method.
Collapse
|
28
|
Barnoy EA, Popovtzer R, Fixler D. Fluorescence for biological logic gates. J Biophotonics 2020; 13:e202000158. [PMID: 32537894 DOI: 10.1002/jbio.202000158] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 06/10/2020] [Accepted: 06/11/2020] [Indexed: 05/03/2023]
Abstract
Biological logic gates are smart probes able to respond to biological conditions in behaviors similar to computer logic gates, and they pose a promising challenge for modern medicine. Researchers are creating many kinds of smart nanostructures that can respond to various biological parameters such as pH, ion presence, and enzyme activity. Each of these conditions alone might be interesting in a biological sense, but their interactions are what define specific disease conditions. Researchers over the past few decades have developed a plethora of stimuli-responsive nanodevices, from activatable fluorescent probes to DNA origami nanomachines, many explicitly defining logic operations. Whereas many smart configurations have been explored, in this review we focus on logic operations actuated through fluorescent signals. We discuss the applicability of fluorescence as a means of logic gate implementation, and consider the use of both fluorescence intensity as well as fluorescence lifetime.
Collapse
Affiliation(s)
- Eran A Barnoy
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Rachela Popovtzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| |
Collapse
|
29
|
Olshinka A, Ad-El D, Didkovski E, Weiss S, Ankri R, Goldenberg-Cohen N, Fixler D. Diffusion Reflection Measurements of Antibodies Conjugated to Gold Nanoparticles as a Method to Identify Cutaneous Squamous Cell Carcinoma Borders. Materials (Basel) 2020; 13:ma13020447. [PMID: 31963462 PMCID: PMC7014005 DOI: 10.3390/ma13020447] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 01/06/2020] [Accepted: 01/13/2020] [Indexed: 12/13/2022]
Abstract
Diffusion reflectance spectroscopy measurements targeted with gold nanoparticles (GNPs) can identify residual cutaneous squamous cell carcinoma (SCC) in excision borders. Human SCC specimens were stained with hematoxylin and eosin to identify tumor borders, and reflected onto an unstained deparaffinized section. Diffusion reflection of three sites (normal and SCC) were measured before and after GNPs targeting. Hyperspectral imaging showed a mean of 2.5 sites with tumor per specimen and 1.2 tumor-free (p < 0.05, t-test). GNPs were detected in 25/30 tumor sites (sensitivity 83.3%, false-negative rate 16.6%) and 12/30 non-tumor sites (specificity 60%, false-positive rate 40%). This study verifies the use of nanotechnology in identifying SCC tumor margins. Diffusion reflection scanning has high sensitivity for detecting the residual tumor.
Collapse
Affiliation(s)
- Asaf Olshinka
- Department of Plastic Surgery, Rabin Medical Center—Beilinson Hospital, Petach Tikva 4941492, Israel; (A.O.); (D.A.-E.)
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (E.D.); (S.W.)
| | - Dean Ad-El
- Department of Plastic Surgery, Rabin Medical Center—Beilinson Hospital, Petach Tikva 4941492, Israel; (A.O.); (D.A.-E.)
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (E.D.); (S.W.)
| | - Elena Didkovski
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (E.D.); (S.W.)
- Department of Pathology and Cytology, Rabin Medical Center—Beilinson Hospital, Petach Tikva 4941492, Israel
| | - Shirel Weiss
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (E.D.); (S.W.)
- The Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 49100, Israel
| | - Rinat Ankri
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel;
| | - Nitza Goldenberg-Cohen
- The Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Petach Tikva 49100, Israel
- Ruth and Bruce Rappaport Faculty of Medicine, The Technion—Technical Institute of Israel, Haifa 3200003, Israel
- Department of Ophthalmology, Bnai Zion Medical Center, Haifa 3339419, Israel
- Correspondance: (N.G.-C.); (D.F.); Tel.: +972-4-835-9554 (N.G.-C.); +972-3-531-7598 (D.F.)
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan 5290002, Israel;
- Correspondance: (N.G.-C.); (D.F.); Tel.: +972-4-835-9554 (N.G.-C.); +972-3-531-7598 (D.F.)
| |
Collapse
|
30
|
Lubart R, Yariv I, Fixler D, Lipovsky A. Topical Hyaluronic Acid Facial Cream with New Micronized Molecule Technology Effectively Penetrates and Improves Facial Skin Quality: Results from In-vitro, Ex-vivo, and In-vivo (Open-label) Studies. J Clin Aesthet Dermatol 2019; 12:39-44. [PMID: 32038748 PMCID: PMC6937149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Background: Topical hyaluronic acid (HA) has shown effectiveness in maintaining skin hydration. Topical creams containing HA are widely available, but their efficacy is limited by their lack of penetration into the skin due to the large molecule size of HA, the result of being formulated into a cream base. Objective: In this three-part study (in vitro, ex vivo, and in vivo), molecule sizes, penetration levels, and antiaging qualities of a topical HA facial cream that was formulated using a new technology that micronizes HA molecules (m-HA) were assessed. Methods and Results: Particle sizes of m-HA were evaluated using electron microscopy, which showed varying sizes, the smallest of which was 100nm in diameter. The antioxidation capabilities of m-HA were measured using electron spin resonance and were found to be higher than original HA. Skin penetration of the m-HA formulation was evaluated via immunohistochemical staining of porcine skin samples, which demonstrated penetration of the formulation into the stratum corneum and the deep epidermal layers toward the dermis. Antiaging qualities of the m-HA formulation were assessed in an open-label clinical study that included 36 healthy adult women. Skin parameters were measured objectively (e.g., Corneometer, Cutometer) and subjectively via patient questionnaire, results of which indicated significant improvements in facial skin hydration, elasticity, and wrinkle depth. Conclusion: The topical HA facial cream with m-HA technology demonstrated penetration into the epidermal skin layer, and, to our knowledge, our formulation is the first HA facial cream to achieve this. Clinical application of the facial cream demonstrated objective and subjective improvements in facial skin quality of healthy adult female subjects. Our results support the use of this new HA facial cream with m-HA technology as an effective antiaging topical therapy. Larger randomized, controlled studies are needed to confirm our findings.
Collapse
Affiliation(s)
- Rachel Lubart
- Prof. Lubart and Dr. Lipovsky are with the Chemistry Department at Bar-Ilan University in Ramat-Gan, Israel. Prof. Lubart is also with the Physics Department at Bar-Ilan University in Ramat-Gan, Israel
- Ms. Yariv and Prof.. Fixler are with the Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University in Ramat-Gan, Israel
| | - Inbar Yariv
- Prof. Lubart and Dr. Lipovsky are with the Chemistry Department at Bar-Ilan University in Ramat-Gan, Israel. Prof. Lubart is also with the Physics Department at Bar-Ilan University in Ramat-Gan, Israel
- Ms. Yariv and Prof.. Fixler are with the Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University in Ramat-Gan, Israel
| | - Dror Fixler
- Prof. Lubart and Dr. Lipovsky are with the Chemistry Department at Bar-Ilan University in Ramat-Gan, Israel. Prof. Lubart is also with the Physics Department at Bar-Ilan University in Ramat-Gan, Israel
- Ms. Yariv and Prof.. Fixler are with the Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University in Ramat-Gan, Israel
| | - Anat Lipovsky
- Prof. Lubart and Dr. Lipovsky are with the Chemistry Department at Bar-Ilan University in Ramat-Gan, Israel. Prof. Lubart is also with the Physics Department at Bar-Ilan University in Ramat-Gan, Israel
- Ms. Yariv and Prof.. Fixler are with the Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University in Ramat-Gan, Israel
| |
Collapse
|
31
|
Yariv I, Shapira C, Duadi H, Fixler D. Media Characterization under Scattering Conditions by Nanophotonics Iterative Multiplane Spectroscopy Measurements. ACS Omega 2019; 4:14301-14306. [PMID: 31508554 PMCID: PMC6733169 DOI: 10.1021/acsomega.9b01976] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 08/09/2019] [Indexed: 05/21/2023]
Abstract
Characterizing materials is preferably done by multiple wavelengths. In opaque materials, the scattering poses a challenge due to the additional complexity to the spectroscopic measurements. We have previously demonstrated an iterative multiplane method for characterizing materials using the reflection from turbid media. Initial studies were performed in the red wavelength regime (632.8 nm) which is optimal for biomedical applications. However, in order to differentiate between materials, it is better to use multiple wavelengths, as spectroscopy may detect the material fingerprint. In this paper, our iterative multiplane optical property extraction (IMOPE) technique is presented in the blue regime (473 nm). Agar-based solid phantom measurements were conducted and compared to our theoretical model. Compatibility between experiments in the red and blue wavelengths shows the robustness of our technique.
Collapse
|
32
|
Yahav G, Diamandi HH, Preter E, Fixler D. The squared distance approach to frequency domain time-resolved fluorescence analysis. J Biophotonics 2019; 12:e201800485. [PMID: 30809961 DOI: 10.1002/jbio.201800485] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2018] [Revised: 02/24/2019] [Accepted: 02/25/2019] [Indexed: 06/09/2023]
Abstract
A frequency-domain (FD) analysis of fluorescence lifetime (FLT) is a unique and rapid method for cellular and intracellular classifications that can serve for medical diagnostics purposes. Nevertheless, its data analysis process demands nonlinear fitting algorithms that may distort the resolution of the FLT data and hence diminish the classification ability of the method. This research suggests a sample classification technique that is unaffected by the analysis process as it is based on the squared distance (D2 ) between the raw frequency response data (FRD). In addition, it presents the theory behind this technique and its validation in two simulated data sets of six groups with similar widely and closely spaced FLT data as well as in experimental data of 43 samples from bacterial and viral infected and non-infected patients. In the two simulated tests, the classification accuracy was above 95% for all six groups. In the experimental data, the classification of 41 out of 43 samples matched earlier report and 29 out of 31 agreed with preliminary physician diagnosis. The D2 approach has the potential to promote FD-time resolved fluorescence measurements as a medical diagnostic technique with high specifity and high sensitivity for many of today's conventional diagnostic procedures.
Collapse
Affiliation(s)
- Gilad Yahav
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Hilel H Diamandi
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Eyal Preter
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| |
Collapse
|
33
|
Yariv I, Duadi H, Chakraborty R, Fixler D. Algorithm for in vivo detection of tissue type from multiple scattering light phase images. Biomed Opt Express 2019; 10:2909-2917. [PMID: 31259061 PMCID: PMC6583353 DOI: 10.1364/boe.10.002909] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 05/15/2019] [Accepted: 05/16/2019] [Indexed: 05/30/2023]
Abstract
In vivo physiological assessments are typically done by either imaging techniques or by sensing changes in the attenuation coefficient. Using visible or near-infrared (NIR), imaging is mainly possible for thin tissues. On the other hand, clinical information can also be detected by examining changes in tissue optical properties. The most challenging aspect in sensing techniques is the spectral dependent scattering, which varies with the physiological state and tissue type. We have previously published our novel noninvasive nanophotonics technique for detecting tissue scattering based on reflectance measurements: the iterative multi-plane optical property extraction (IMOPE). The IMOPE reconstructs the reemitted light phase using an iterative algorithm and extracts the scattering properties based on a theoretical model. This paper presents the in vivo application of distinguishing between different mouse tissue areas. The reconstructed phase images reveal different areas in the inner thigh of a mouse, which are related to the muscle, bone, and skin. The IMOPE uses the reconstructed phases for sensing and detecting unseen components beneath the skin surface. This technique could be further applied to the diagnosis of various physiological states.
Collapse
|
34
|
Fixler D, Tzur C, Zalevsky Z. Genetic Algorithm-Based Design for Metal-Enhanced Fluorescent Nanostructures. Materials (Basel) 2019; 12:ma12111766. [PMID: 31151325 PMCID: PMC6600714 DOI: 10.3390/ma12111766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 05/20/2019] [Accepted: 05/28/2019] [Indexed: 06/09/2023]
Abstract
In this paper, we present our optimization tool for fluorophore-conjugated metal nanostructures for the purpose of designing novel contrast agents for multimodal bioimaging. Contrast agents are of great importance to biological imaging. They usually include nanoelements causing a reduction in the need for harmful materials and improvement in the quality of the captured images. Thus, smart design tools that are based on evolutionary algorithms and machine learning definitely provide a technological leap in the fluorescence bioimaging world. This article proposes the usage of properly designed metallic structures that change their fluorescence properties when the dye molecules and the plasmonic nanoparticles interact. The nanostructures design and evaluation processes are based upon genetic algorithms, and they result in an optimal separation distance, orientation angles, and aspect ratio of the metal nanostructure.
Collapse
Affiliation(s)
- Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel.
| | - Chen Tzur
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel.
| | - Zeev Zalevsky
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 5290002, Israel.
| |
Collapse
|
35
|
Elhalel G, Price C, Fixler D, Shainberg A. Cardioprotection from stress conditions by weak magnetic fields in the Schumann Resonance band. Sci Rep 2019; 9:1645. [PMID: 30733450 PMCID: PMC6367437 DOI: 10.1038/s41598-018-36341-z] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Accepted: 11/19/2018] [Indexed: 01/19/2023] Open
Abstract
The Schumann Resonances (ScR) are Extremely Low Frequency (ELF) electromagnetic resonances in the Earth-ionosphere cavity excited by global lightning discharges. This natural electromagnetic noise has likely existed on the Earth ever since the Earth had an atmosphere and an ionosphere, hence surrounding us throughout our evolutionary history. The purpose of this study was to examine the influence of extremely weak magnetic fields in the ScR first mode frequency range on the spontaneous contractions, calcium transients and Creatine Kinase (CK) release of rat cardiac cell cultures. We show that applying 7.8 Hz, 90 nT magnetic fields (MF) causes a gradual decrease in the spontaneous calcium transients’ amplitude, reaching 28% of the initial amplitude after 40 minutes of MF application, and accompanied with a gradual decrease in the calcium transients’ rise time. The mechanical spontaneous contractions cease after the ScR fields have been applied for more than 30 minutes, when the calcium transient’s amplitude reached ~60% of its initial value. The influence of the ScR MF was reversible, independent of the field magnitude in the range 20 pT-100 nT, and independent of the external DC magnetic field. However, the effect is frequency dependent; the described changes occurred only in the 7.6–8 Hz range. In addition, applying 7.8 Hz, 90 nT MF for 1.5 hours, reduced the amount of CK released to the buffer, during normal conditions, hypoxic conditions and oxidative stress induced by 80 μM H2O2. We show that the ScR field induced reduction in CK release is associated with a stress response process and has a protective character.
Collapse
Affiliation(s)
- G Elhalel
- Porter School of the Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
| | - C Price
- Porter School of the Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel.
| | - D Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Tel Aviv, Israel
| | - A Shainberg
- Faculty of Life Sciences, Bar Ilan University, Tel Aviv, Israel
| |
Collapse
|
36
|
Chakraborty R, Ankri R, Leshem-Lev D, Hochhauser E, Kornowski R, Motiei M, Lev EI, Fixler D. Hyperlipidemic mice as a model for a real-time in vivo detection of atherosclerosis by gold nanorods-based diffusion reflection technique. J Biophotonics 2019; 12:e201800218. [PMID: 30141260 DOI: 10.1002/jbio.201800218] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Revised: 07/20/2018] [Accepted: 08/22/2018] [Indexed: 05/11/2023]
Abstract
Atherosclerosis (AS), the leading cause of morbidity and mortality in cardiovascular disease, needs an early detection for treatment and prevention of fatal events. Here, for the first time, we applied gold nanorods (GNRs)-assisted diffusion reflection (DR), a noninvasive technique for in vivo detection of AS in a high-fat-diet-induced c57bl mouse model, which resembles the manifestation of AS in humans. DR simply detects the change in light reflection profile of tissue due to the accumulation of GNRs in the AS plaques and enables clear detection of AS lesions in carotid and femoral arteries of these hyperlipidemic mice. After 24 hours post-GNRs injection, DR showed the highest efficiency of AS detection. Moreover, the sensitivity of the DR method is much higher than computed tomography (CT) and is comparable to ex vivo high-resolution CT. Our results strongly suggest that the DR method can detect early atherosclerotic lesions in a sensitive and specific manner.
Collapse
Affiliation(s)
- Ruchira Chakraborty
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Rinat Ankri
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Dorit Leshem-Lev
- Cardiac Research Laboratories at the Felsenstein Medical Research Center and the Cardiology Department, Rabin Medical Center, Petah Tikva, Israel
| | - Edith Hochhauser
- Cardiac Research Laboratories at the Felsenstein Medical Research Center and the Cardiology Department, Rabin Medical Center, Petah Tikva, Israel
| | - Ran Kornowski
- Cardiac Research Laboratories at the Felsenstein Medical Research Center and the Cardiology Department, Rabin Medical Center, Petah Tikva, Israel
| | - Menachem Motiei
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Eli I Lev
- Cardiac Research Laboratories at the Felsenstein Medical Research Center and the Cardiology Department, Rabin Medical Center, Petah Tikva, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| |
Collapse
|
37
|
Yariv I, Duadi H, Fixler D. Optical method to extract the reduced scattering coefficient from tissue: theory and experiments. Opt Lett 2018; 43:5299-5302. [PMID: 30382992 DOI: 10.1364/ol.43.005299] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 09/24/2018] [Indexed: 06/08/2023]
Abstract
Tissues are considered challenging in terms of structure and composition analysis due to their tendency to multiple scatter the incident light. One of the most common theories for extracting optical properties of tissue is diffusion reflection (DR). In this Letter, we propose a new paradigm for estimating the reduced scattering coefficient of a medium from the reflected light phase. The technique is a modified DR theory wherein the phase is calculated by the product of the wavenumber and the average pathlength. This theory is supported by the reconstructed phase of tissue-like phantom experiments from an iterative algorithm.
Collapse
|
38
|
Niu Y, Ling G, Wang L, Guan S, Xie Z, Barnoy EA, Zhou S, Fixler D. Gold Rod-Polyethylene Glycol-Carbon Dot Nanohybrids as Phototheranostic Probes. Nanomaterials (Basel) 2018; 8:E706. [PMID: 30201913 PMCID: PMC6165167 DOI: 10.3390/nano8090706] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 09/03/2018] [Accepted: 09/05/2018] [Indexed: 12/17/2022]
Abstract
Emphasis using phototheranostics has been placed on the construction of multifunctional nanoplatforms for simultaneous tumor diagnosis and therapy. Herein, we put forth a novel nanosized luminescent material using the incorporation of red emissive carbon dots on gold nanorods through polyethylene glycol as a covalent linkage for dual-modal imaging and photothermal therapy. The novel nanohybrids, not only retain the optical properties of the gold nanorod and carbon dots, but also possess superior imaging performance in both confocal laser scanning microscopy and fluorescence lifetime imaging microscopy. The nanohybrids also exhibit excellent photothermal performance as phototheranostic nanohybrid probes for in vitro assays. This study promises a new multifunctional nanoplatform for cancer diagnostics and therapeutics.
Collapse
Affiliation(s)
- Yuefang Niu
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China.
- University of Chinese Academy of Sciences, 19A Yuquan Road, Shijingshan District, Beijing 100049, China.
| | - Guo Ling
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China.
| | - Li Wang
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China.
- University of Chinese Academy of Sciences, 19A Yuquan Road, Shijingshan District, Beijing 100049, China.
| | - Shanyue Guan
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China.
| | - Zheng Xie
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China.
| | - Eran A Barnoy
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 52900, Israel.
| | - Shuyun Zhou
- Key Laboratory of Photochemical Conversion and Optoelectronic Materials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing 100190, China.
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 52900, Israel.
| |
Collapse
|
39
|
Ankri R, Chakraborty R, Motiei M, Fixler D. Three-Dimensional Highly Sensitive Diffusion Reflection-Based Imaging Method for the in Vivo Localization of Atherosclerosis Plaques Following Gold Nanorods Accumulation. ACS Omega 2018; 3:6134-6142. [PMID: 30023941 PMCID: PMC6045478 DOI: 10.1021/acsomega.8b00750] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 05/23/2018] [Indexed: 05/11/2023]
Abstract
In this work, we present a novel, simple, and highly accurate three-dimensional (3D) diffusion reflection (DR) imaging system and method for the detection of accumulation sites of gold nanorods (GNRs) within the tissue. GNRs are intensively used for diagnosis purposes of varied diseases, mainly because of their ability to well absorb visible light, which introduces them as terrific contrast agents in various imaging and theranostics methods. Lately, these GNRs unique absorption properties have served in DR intensity-based measurements, suggesting a novel diagnostic tool, DR-GNRs. In this paper, we show a new measurement system and method for DR, based on its radial collection from the tissue. These radial measurements enabled a unique 3D presentation of the DR-GNR, introducing the dimensions ρ for the radius, θ for the angle, and Γ for the reflected intensity. On the basis of the diffusion model, which enables to correlate between the sample's optical properties and its reflectance, a unique, radial map is presented. This map introduces the slopes of the DR curves in each measured angle, which are linearly correlated with the tissue's optical properties and with the GNRs concentrations within the tissue, thus enables the exact radial localization of the GNRs in the sample. We show the detection of macrophage accumulation in tissue-like phantoms, as well as the localization of unstable plaques in hyperlipidemic mice, in vivo. This highly accurate, powerful technology paves the way toward a real-time detection method that can be successfully integrated in the rapid increasing field of personalized medicine.
Collapse
Affiliation(s)
| | | | | | - Dror Fixler
- E-mail: . Phone: +972-3-5317598. Fax: +972-3-7384050 (D.F.)
| |
Collapse
|
40
|
Duadi H, Feder I, Fixler D. Near-infrared human finger measurements based on self-calibration point: Simulation and in vivo experiments. J Biophotonics 2018; 11:e201700208. [PMID: 29131520 DOI: 10.1002/jbio.201700208] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Accepted: 11/09/2017] [Indexed: 05/26/2023]
Abstract
Near-infrared light allows measuring tissue oxygenation. These measurements relay on oxygenation-dependent absorption spectral changes. However, the tissue scattering, which is also spectral dependent, introduces an intrinsic error. Most methods focus on the volume reflectance from a semi-infinite sample. We have proposed examining the full scattering profile (FSP), which is the angular intensity distribution. A point was found, that is, the iso-path length (IPL) point, which is not dependent on the tissue scattering, and can serve for self-calibration. This point is geometric dependent, hence in cylindrical tissues depends solely on the diameter. In this work, we examine an elliptic tissue cross section via Monte Carlo simulation. We have found that the IPL point of an elliptic tissue cross section is indifferent to the input illumination orientation. Furthermore, the IPL point is the same as in a circular cross section with a radius equal to the effective ellipse radius. This is despite the fact that the FSPs of the circular and elliptical cross sections are different. Hence, changing the orientation of the input illumination reveals the IPL point. In order to demonstrate this experimentally, the FSPs of a few female fingers were measured at 2 perpendicular orientations. The crossing point between these FSPs was found equivalent to the IPL point of a cylindrical phantom with a radius similar to the effective radius. The findings of this work will allow accurate pulse oximetry assessment of blood saturation.
Collapse
Affiliation(s)
- Hamootal Duadi
- Faculty of Engineering, Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Idit Feder
- Faculty of Engineering, Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Dror Fixler
- Faculty of Engineering, Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| |
Collapse
|
41
|
Haddad M, Popovtzer R, Yariv I, Motiei M, Fixler D. [CONCISE NANOMEDICINE REVIEW]. Harefuah 2018; 157:232-236. [PMID: 29688641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Nanomedicine is a rapidly evolving medical domain utilizing 1-100nm nanoscale particles to achieve medical goals in either one or more medical aspects - diagnosis, imaging and therapy. Nanomedicine employs a combination of methods stemming from life and exact sciences. This review deals briefly with the principles behind the scenes guiding the design, manufacture and employment of these nanoparticles. Some representative examples of the various applications are provided from the abundance of existing nanoparticles. The main topics discussed are those related to composition, characteristics of nanoparticles, usage in cancer, drug delivery and various central nervous system applications. Possible toxicity and future teratogenicity research pertaining to nanoparticles are also elaborated upon.
Collapse
Affiliation(s)
- Menashe Haddad
- Sackler Faculty of Medicine, Tel-Aviv University
- Mayanei Hayeshua Medical Center
| | - Rachela Popovtzer
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University
| | - Inbar Yariv
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University
| | - Menachem Motiei
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University
| |
Collapse
|
42
|
Feder I, Duadi H, Chakraborty R, Fixler D. Self-Calibration Phenomenon for Near-Infrared Clinical Measurements: Theory, Simulation, and Experiments. ACS Omega 2018; 3:2837-2844. [PMID: 30221222 PMCID: PMC6130783 DOI: 10.1021/acsomega.8b00018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 02/22/2018] [Indexed: 05/13/2023]
Abstract
An irradiated turbid medium scatters the light in accordance to its optical properties. Near-infrared (NIR) clinical methods, which are based on spectral-dependent absorption, suffer from an inherent error due to spectral-dependent scattering. We present here a unique spatial point, that is, iso-pathlength (IPL) point, on the surface of a tissue at which the intensity of re-emitted light remains constant. This scattering-indifferent point depends solely on the medium geometry. On the basis of this natural phenomenon, we suggest a novel optical method for self-calibrated clinical measurements. We found that the IPL point exists in both cylindrical and semi-infinite tissue geometries (Supporting Information, Video file). Finally, in vivo human finger and mice measurements are used to validate the crossing point between the intensity profiles of two wavelengths. Hence, measurements at the IPL point yield an accurate absorption assessment while eliminating the scattering dependence. This finding can be useful for oxygen saturation determination, NIR spectroscopy, photoplethysmography measurements, and a wide range of optical sensing methods for physiological aims.
Collapse
|
43
|
Yahav G, Gershanov S, Salmon-Divon M, Ben-Zvi H, Mircus G, Goldenberg-Cohen N, Fixler D. Pathogen Detection Using Frequency Domain Fluorescent Lifetime Measurements. IEEE Trans Biomed Eng 2018; 65:2731-2741. [PMID: 29993446 DOI: 10.1109/tbme.2018.2814597] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Inflammation of the meninges is a source of severe morbidity and therefore is an important health concerns worldwide. The conventional clinical microbiology approaches used today to identify pathogens suffer from several drawbacks and frequently provide false results. This research describes a fast method to detect the presence of pathogens using the frequency domain (FD) fluorescence lifetime (FLT) imaging microscopy (FLIM) system. METHODS The study included 43 individuals divided into 4 groups: 9 diagnosed with different types of bacteria; 16 diagnosed with different types of viruses; 5 healthy samples served as a control; and 12 samples were negative to any pathogen, although presenting related symptoms. All samples contained leukocytes that were extracted from the cerebrospinal fluid (CSF) and were subjected to nuclear staining by 4', 6-diamidino-2-phenylindole (DAPI) and FLT analyses based on phase and amplitude crossing point (CRPO). RESULTS Using notched boxplots, we found differences in 95% probability between the first three groups through different notch ranges (NR). Pathogen samples presented a longer median FLT (3.28 ns with NR of 3.24-3.32 ns in bacteria and 3.18 ns with NR of 3.16-3.21 ns in viruses) compared to the control median FLT (2.65 ns with NR of 2.63-2.67 ns). Furthermore, we found that the undetected forth group was divided into two types: a relatively normal median FLT (2.72 ns with NR of 2.68-2.76 ns) and a prolonged FLT (3.22 ns with NR of 3.17-3.27 ns). CONCLUSION FLT measurements can differentiate between control and pathogen by the CRPO method. SIGNIFICANCE The FD-FLIM system can provide a high throughput diagnostic technique that does not require a physician.
Collapse
|
44
|
Barnoy EA, Popovtzer R, Fixler D. Development of a molecular bioswitch using fluorescence lifetime imaging: Incremental activation of fluorescein diacetate. J Biophotonics 2018; 11:e201700084. [PMID: 28700140 DOI: 10.1002/jbio.201700084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Revised: 05/22/2017] [Accepted: 05/23/2017] [Indexed: 06/07/2023]
Abstract
Molecular bioswitches offer an invaluable asset in the shift from systemic to targeted treatments. Within the growing arsenal of switches are imaging probes that functionalize only in given locations or situations. Acetate esters are a common fluorescent example, known to activate upon interaction with esterases. Fluorescein diacetate (FDA) is one such fluorophore used in cell viability assays. These assays rely on the fact that the compound begins colorless and with no fluorescent signature whatsoever, and only after internalization into cells it is possible to detect a fluorescence signal. In this study, using fluorescence intensity (FI) and fluorescence lifetime (FLT) imaging, FDA is shown to be fluorescent even when unactivated. Furthermore, the FLT is shown to change with pH. Finally, the ability to image FDA in different environments simulated by tissue-imitating phantoms is explored. Altogether, the ability of FDA to serve as a bioswitch when measured using FLT imaging microscopy (FLIM) is assessed. The combination of a spectrum of FDA activation and FLIM serves as a bioswitch, where biologically relevant stimulation can generate detectable and incremental variations.
Collapse
Affiliation(s)
- Eran A Barnoy
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Rachela Popovtzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| |
Collapse
|
45
|
Yahav G, Barnoy E, Roth N, Turgeman L, Fixler D. Reference-independent wide field fluorescence lifetime measurements using Frequency-Domain (FD) technique based on phase and amplitude crossing point. J Biophotonics 2017; 10:1198-1207. [PMID: 27774782 DOI: 10.1002/jbio.201600220] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 09/29/2016] [Accepted: 09/30/2016] [Indexed: 06/06/2023]
Abstract
Fluorescence lifetime imaging microscopy (FLIM) is an essential tool in many scientific fields such as biology and medicine thanks to the known advantages of the fluorescence lifetime (FLT) over the classical fluorescence intensity (FI). However, the frequency domain (FD) FLIM technique suffers from its strong dependence on the reference and its compliance to the sample. In this paper, we suggest a new way to calculate the FLT by using the crossing point (CRPO) between the modulation and phase FLTs measured over several light emitting diode (LED) DC currents values instead of either method alone. This new technique was validated by measuring homogeneous substances with known FLT, where the CRPO appears to be the optimal measuring point. Furthermore, the CRPO method was applied in heterogeneous samples. It was found that the CRPO in known mixed solutions is the weighted average of the used solutions. While measuring B16 and lymphocyte cells, the CRPO of the DAPI compound in single FLT regions was measured at 3.5 ± 0.06 ns and at 2.83 ± 0.07 ns, respectively, both of which match previous reports and multi-frequency analyses. This paper suggests the CRPO as a new method to extract the FLT in problematic cases such as high MCP gains and heterogeneous environments. In traditional FD FLIM measurements, the variation in phase angle and modulation are measured. By measuring over varying DC currents, another variation is detected in the FLT determined through the phase and modulation methods, with the CRPO indicating the true FLT.
Collapse
Affiliation(s)
- Gilad Yahav
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Eran Barnoy
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Nir Roth
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, 5290002, Ramat Gan, Israel
| | - Lior Turgeman
- Joseph M. Katz Graduate School of Business, University of Pittsburgh, Roberto Clemente Dr, PA, 15260, Pittsburgh, USA
| | - Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, 5290002, Ramat Gan, Israel
| |
Collapse
|
46
|
Affiliation(s)
- Dror Fixler
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, Israel
| | - James F Leary
- School of Veterinary Medicine Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA
| | - Xunbin Wei
- School of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
47
|
Emanuelov A, Bouaziz P, Leinonen J, Ankri R, Hoss S, Lotan C, Fixler D, Beeri R. P1573The left atrial appendagea -biological band aid for cardiac tissue regeneration. Eur Heart J 2017. [DOI: 10.1093/eurheartj/ehx502.p1573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
48
|
Gershanov S, Michowiz S, Toledano H, Yahav G, Barinfeld O, Hirshberg A, Ben-Zvi H, Mircus G, Salmon-Divon M, Fixler D, Goldenberg-Cohen N. Fluorescence Lifetime Imaging Microscopy, a Novel Diagnostic Tool for Metastatic Cell Detection in the Cerebrospinal Fluid of Children with Medulloblastoma. Sci Rep 2017. [PMID: 28623325 PMCID: PMC5473849 DOI: 10.1038/s41598-017-03892-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
In pediatric brain tumours, dissemination of malignant cells within the central nervous system confers poor prognosis and determines treatment intensity, but is often undetectable by imaging or cytology. This study describes the use of fluorescence lifetime (FLT) imaging microscopy (FLIM), a novel diagnostic tool, for detection of metastatic spread. The study group included 15 children with medulloblastoma and 2 with atypical teratoid/rhabdoid tumour. Cells extracted from the tumour and the cerebrospinal fluid (CSF) 2 weeks postoperatively and repeatedly during chemo/radiotherapy were subjected to nuclear staining followed by FLT measurement and cytological study. Control CSF samples were collected from patients with infectious/inflammatory disease attending the same hospital. Median FLT was prolonged in tumour cells (4.27 ± 0.28 ns; P < 2.2*10−16) and CSF metastatic cells obtained before chemo/radiotherapy (6.28 ± 0.22 ns; P < 2.2*10−16); normal in inflammatory control cells (2.6 ± 0.04 ns) and cells from children without metastasis before chemo/radiotherapy (2.62 ± 0.23 ns; P = 0.858) and following treatment (2.62 ± 0.21 ns; P = 0.053); and short in CSF metastatic cells obtained after chemo/radiotherapy (2.40 ± 0.2 ns; P < 2.2*10−16). FLIM is a simple test that can potentially identify CSF spread of brain tumours. FLT changes in accordance with treatment, with significant prolonged median values in tumours and metastases. More accurate detection of metastatic cells may guide personalised treatment and improve the therapeutic outcome.
Collapse
Affiliation(s)
- Sivan Gershanov
- Genomic Bioinformatics Laboratory, Department of Molecular Biology, Ariel University, Ariel, 40700, Israel.,The Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Beilinson Hospital, Petach Tikva 4941492, affiliated to Tel Aviv University, Tel Aviv, 6997801, Israel
| | - Shalom Michowiz
- Department of Pediatric Neurosurgery, Schneider Children's Medical Center of Israel, Petach Tikva, 4920235, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, 6997801, Israel
| | - Helen Toledano
- Department of Pediatric Oncology, Schneider Children's Medical Center of Israel, Petach Tikva, 4920235, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, 6997801, Israel
| | - Gilad Yahav
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Orit Barinfeld
- The Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Beilinson Hospital, Petach Tikva 4941492, affiliated to Tel Aviv University, Tel Aviv, 6997801, Israel.,Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, 6997801, Israel
| | - Avraham Hirshberg
- Department of Oral Pathology and Oral Medicine, Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, 6997801, Israel
| | - Haim Ben-Zvi
- Laboratory of Microbiology, Rabin Medical Center - Beilinson Hospital, Petach Tikva, 4941492, Israel
| | - Gabriel Mircus
- Laboratory of Microbiology, Rabin Medical Center - Beilinson Hospital, Petach Tikva, 4941492, Israel
| | - Mali Salmon-Divon
- Genomic Bioinformatics Laboratory, Department of Molecular Biology, Ariel University, Ariel, 40700, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar Ilan University, Ramat Gan, 5290002, Israel
| | - Nitza Goldenberg-Cohen
- The Krieger Eye Research Laboratory, Felsenstein Medical Research Center, Beilinson Hospital, Petach Tikva 4941492, affiliated to Tel Aviv University, Tel Aviv, 6997801, Israel. .,Department of Ophthalmology, Bnai Zion Medical Center, Haifa, 3339419, Israel.
| |
Collapse
|
49
|
Hirshberg A, Allon I, Novikov I, Ankri R, Ashkenazy A, Fixler D. Gold nanorods reflectance discriminate benign from malignant oral lesions. Nanomedicine 2017; 13:1333-1339. [PMID: 28115253 DOI: 10.1016/j.nano.2017.01.003] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Revised: 12/13/2016] [Accepted: 01/01/2017] [Indexed: 12/26/2022]
Abstract
Nanoparticle-based contrast agents have been used as an imaging tool for selectively detecting cancerous processes. We aimed to evaluate the detection sensitivity of reflection measurements of gold nanorods (GNRs) bio-conjugated to anti-epidermal growth factor receptor (GNRs-EGFR) monoclonal antibodies in discriminating benign from premalignant and malignant human oral lesions. Tissue sections incubated with GNRs-EGFR and the reflectance spectrum was measured using hyperspectral microscopy. Reflectance intensity increased with the progression of the disease, lowest in the control group and increasing as the dysplastic changes increase (P<0.001 for linear trend of grade). Intensity was significantly higher in the moderate and severe dysplasias and cancer patients than in the controls and mild dysplasia (t test P=0.0003, Mann-Whitney P<0.0001). The GNRs reflection measurements can discriminate benign and mild dysplastic lesions from the more severe dysplasia and invasive cancer, suggesting an objective, not dependent on the qualification of a technician and with less interpretation errors.
Collapse
Affiliation(s)
- Abraham Hirshberg
- Department of Oral Pathology and Oral Medicine, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Irit Allon
- Department of Oral Pathology and Oral Medicine, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Ilya Novikov
- Biostatistical Unit, Gertner institute for Epidemiology and Health Policy Research, Ramat Gan, Israel
| | - Rinat Ankri
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, Israel
| | - Ariel Ashkenazy
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, Israel
| | - Dror Fixler
- Faculty of Engineering and Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan, Israel
| |
Collapse
|
50
|
Feder I, Duadi H, Fridman M, Dreifuss T, Fixler D. Experimentally testing the role of blood vessels in the full scattering profile: solid phantom measurements. JBPE 2016. [DOI: 10.18287/jbpe16.02.040301] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|