1
|
Cuenca-Gómez D, De Paco Matallana C, Rolle V, Mendoza M, Valiño N, Revello R, Adiego B, Casanova MC, Molina FS, Delgado JL, Wright A, Figueras F, Nicolaides KH, Santacruz B, Gil MM. Comparison of different methods of screening for preterm pre-eclampsia: cohort study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2024. [PMID: 38411276 DOI: 10.1002/uog.27622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 02/10/2024] [Accepted: 02/13/2024] [Indexed: 02/28/2024]
Abstract
OBJECTIVE To compare the predictive performance for pre-eclampsia (PE) of three different first-trimester mathematical models of screening, which combine maternal risk factors with mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI) and serum placental growth factor (PlGF), and two risk scoring systems, based on NICE and ACOG recommendations. METHODS This was a prospective cohort study performed in eight fetal-medicine units in five different regions of Spain between September 2017 and December 2019. All pregnant women with singleton pregnancies and non-malformed live fetuses attending their routine ultrasound examination at 11+0 to 13+6 weeks' gestation were invited to participate in the study. Maternal characteristics and medical history were recorded and measurements of MAP, UtA-PI, serum PlGF and pregnancy associated plasma protein-A (PAPP-A) were converted into multiples of the median (MoM). Risks for term, preterm-PE (< 37 weeks' gestation) and early-PE (< 34 weeks' gestation) were calculated according to the FMF competing risks model, the Crovetto et al., logistic regression model, and Serra et al., Gaussian model. Patient classification based on NICE and ACOG guidelines was also performed. We estimated detection rates (DR) with their 95% confidence intervals (CIs) at a fixed 10% screen positive rate (SPR), as well as the area under the receiver operating characteristic curve (AUROC) for preterm-PE, early-PE, and all PE for the three mathematical models. For the scoring systems, we calculated DR and SPR. Risk calibration was also assessed. RESULTS The study population comprised of 10,110 singleton pregnancies, including 32 (0.3%) that developed early-PE, 72 (0.7%) that developed preterm-PE and 230 (2.3%) of any PE. At fixed 10% SPR, the FMF, Crovetto et al., and Serra et al., detected 82.7% (95% CI, 69.6 to 95.8%), 73.8% (95% CI, 58.7 to 88.9%), and 79.8% (95% CI, 66.1 to 93.5%) of early-PE; 72.7% (95% CI, 62.9 to 82.6%), 69.2% (95% CI, 58.8 to 79.6%), and 74.1% (95% CI, 64.2 to 83.9%) of preterm-PE and 55.1% (95% CI, 48.8 to 61.4%), 47.1% (95% CI, 40.6 to 53.5%), and 53.9% (95% CI, 47.4 to 60.4%) of all PE, respectively. The best correlation between predicted and observed cases was achieved by the FMF model, with an AUROC of 0.911 (95% CI, 0.879 to 0.943), a slope of 0.983 (95% CI, 0.846-1.120) and an intercept of 0.154 (95% CI, -0.091 to 0.397). The NICE criteria identified 46.7% (95% CI, 35.3 to 58.0%) of preterm-PE at 11% SPR and ACOG criteria identified 65.9% (95% CI, 55.4 to 76.4%) of preterm-PE at 33.8% SPR. CONCLUSIONS The best performance of screening for preterm-PE is achieved by mathematical models that combine maternal factors with MAP, UtA-PI and PlGF, as compared to risk-scoring systems like NICE or ACOG criteria. While all three algorithms show similar results in terms of overall prediction, the FMF model showed the best performance at the individual level. This article is protected by copyright. All rights reserved.
Collapse
|
2
|
Wright A, Wright D, Chaveeva P, Molina FS, Akolekar R, Syngelaki A, Petersen OB, Kristensen SE, Nicolaides KH. Fetal Medicine Foundation charts for fetal growth in twins. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2024; 63:181-188. [PMID: 37842873 DOI: 10.1002/uog.27514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 09/15/2023] [Accepted: 09/28/2023] [Indexed: 10/17/2023]
Abstract
OBJECTIVE To derive reference distributions of estimated fetal weight (EFW) in twins relative to singletons. METHODS Gestational-age- and chorionicity-specific reference distributions for singleton percentiles and EFW were fitted to data on 4391 twin pregnancies with two liveborn fetuses from four European centers, including 3323 dichorionic (DC) and 1068 monochorionic diamniotic (MCDA) twin pregnancies. Gestational age was derived using the larger of the two crown-rump length measurements obtained during the first trimester of pregnancy. EFW was obtained from ultrasound measurements of head circumference, abdominal circumference and femur length using the Hadlock formula. Singleton percentiles were obtained using the Fetal Medicine Foundation population weight charts for singleton pregnancies. Hierarchical models were fitted to singleton Z-scores with autoregressive terms for serial correlations within the same fetus and between twins from the same pregnancy. Separate models were fitted for DC and MCDA twins. RESULTS Fetuses from twin pregnancies tended to be smaller than singletons at the earliest gestational ages (16 weeks for MCDA and 20 weeks for DC twins). This was followed by a period of catch-up growth until around 24 weeks. After that, both DC and MCDA twins showed reduced growth. In DC twins, the EFW corresponding to the 50th percentile was at the 50th percentile of singleton pregnancies at 23 weeks, the 43rd percentile at 28 weeks, the 32nd percentile at 32 weeks and the 22nd percentile at 36 weeks. In MCDA twins, the EFW corresponding to the 50th percentile was at the 36th percentile of singleton pregnancies at 24 weeks, the 29th percentile at 28 weeks, the 19th percentile at 32 weeks and the 12th percentile at 36 weeks. CONCLUSIONS In DC and, to a greater extent, MCDA twin pregnancies, fetal growth is reduced compared with that observed in singleton pregnancies. Furthermore, after 24 weeks, the divergence in growth trajectories between twin and singleton pregnancies becomes more pronounced as gestational age increases. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
3
|
Gil MM, Cuenca-Gómez D, Rolle V, Pertegal M, Díaz C, Revello R, Adiego B, Mendoza M, Molina FS, Santacruz B, Ansbacher-Feldman Z, Meiri H, Martin-Alonso R, Louzoun Y, De Paco Matallana C. Validation of machine-learning model for first-trimester prediction of pre-eclampsia using cohort from PREVAL study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2024; 63:68-74. [PMID: 37698356 DOI: 10.1002/uog.27478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 07/28/2023] [Accepted: 08/15/2023] [Indexed: 09/13/2023]
Abstract
OBJECTIVE Effective first-trimester screening for pre-eclampsia (PE) can be achieved using a competing-risks model that combines risk factors from the maternal history with multiples of the median (MoM) values of biomarkers. A new model using artificial intelligence through machine-learning methods has been shown to achieve similar screening performance without the need for conversion of raw data of biomarkers into MoM. This study aimed to investigate whether this model can be used across populations without specific adaptations. METHODS Previously, a machine-learning model derived with the use of a fully connected neural network for first-trimester prediction of early (< 34 weeks), preterm (< 37 weeks) and all PE was developed and tested in a cohort of pregnant women in the UK. The model was based on maternal risk factors and mean arterial blood pressure (MAP), uterine artery pulsatility index (UtA-PI), placental growth factor (PlGF) and pregnancy-associated plasma protein-A (PAPP-A). In this study, the model was applied to a dataset of 10 110 singleton pregnancies examined in Spain who participated in the first-trimester PE validation (PREVAL) study, in which first-trimester screening for PE was carried out using the Fetal Medicine Foundation (FMF) competing-risks model. The performance of screening was assessed by examining the area under the receiver-operating-characteristics curve (AUC) and detection rate (DR) at a 10% screen-positive rate (SPR). These indices were compared with those derived from the application of the FMF competing-risks model. The performance of screening was poor if no adjustment was made for the analyzer used to measure PlGF, which was different in the UK and Spain. Therefore, adjustment for the analyzer used was performed using simple linear regression. RESULTS The DRs at 10% SPR for early, preterm and all PE with the machine-learning model were 84.4% (95% CI, 67.2-94.7%), 77.8% (95% CI, 66.4-86.7%) and 55.7% (95% CI, 49.0-62.2%), respectively, with the corresponding AUCs of 0.920 (95% CI, 0.864-0.975), 0.913 (95% CI, 0.882-0.944) and 0.846 (95% CI, 0.820-0.872). This performance was achieved with the use of three of the biomarkers (MAP, UtA-PI and PlGF); inclusion of PAPP-A did not provide significant improvement in DR. The machine-learning model had similar performance to that achieved by the FMF competing-risks model (DR at 10% SPR, 82.7% (95% CI, 69.6-95.8%) for early PE, 72.7% (95% CI, 62.9-82.6%) for preterm PE and 55.1% (95% CI, 48.8-61.4%) for all PE) without requiring specific adaptations to the population. CONCLUSIONS A machine-learning model for first-trimester prediction of PE based on a neural network provides effective screening for PE that can be applied in different populations. However, before doing so, it is essential to make adjustments for the analyzer used for biochemical testing. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
4
|
Cuenca-Gómez D, de Paco Matallana C, Rolle V, Valiño N, Revello R, Adiego B, Mendoza M, Molina FS, Carrillo MP, Delgado JL, Wright A, Santacruz B, Gil MM. Performance of first-trimester combined screening for preterm pre-eclampsia: findings from cohort of 10 110 pregnancies in Spain. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2023; 62:522-530. [PMID: 37099759 DOI: 10.1002/uog.26233] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 04/05/2023] [Accepted: 04/13/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE To evaluate the diagnostic accuracy of the Fetal Medicine Foundation (FMF) competing-risks model, incorporating maternal characteristics, mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI) and placental growth factor (PlGF) (the 'triple test'), for the prediction at 11-13 weeks' gestation of preterm pre-eclampsia (PE) in a Spanish population. METHODS This was a prospective cohort study performed in eight fetal medicine units in five different regions of Spain between September 2017 and December 2019. All pregnant women with a singleton pregnancy and a non-malformed live fetus attending a routine ultrasound examination at 11 + 0 to 13 + 6 weeks' gestation were invited to participate. Maternal demographic characteristics and medical history were recorded and MAP, UtA-PI, serum PlGF and pregnancy-associated plasma protein-A (PAPP-A) were measured following standardized protocols. Treatment with aspirin during pregnancy was also recorded. Raw values of biomarkers were converted into multiples of the median (MoM), and audits were performed periodically to provide regular feedback to operators and laboratories. Patient-specific risks for term and preterm PE were calculated according to the FMF competing-risks model, blinded to pregnancy outcome. The performance of screening for PE, taking into account aspirin use, was assessed by calculating the area under the receiver-operating-characteristics curve (AUC) and detection rate (DR) at a 10% fixed screen-positive rate (SPR). Risk calibration of the model was assessed. RESULTS The study population comprised 10 110 singleton pregnancies, including 72 (0.7%) that developed preterm PE. In the preterm PE group, compared to those without PE, median MAP MoM and UtA-PI MoM were significantly higher, and median serum PlGF MoM and PAPP-A MoM were significantly lower. In women with PE, the deviation from normal in all biomarkers was inversely related to gestational age at delivery. Screening for preterm PE by a combination of maternal characteristics and medical history with MAP, UtA-PI and PlGF had a DR, at 10% SPR, of 72.7% (95% CI, 62.9-82.6%). An alternative strategy of replacing PlGF with PAPP-A in the triple test was associated with poorer screening performance for preterm PE, giving a DR of 66.5% (95% CI, 55.8-77.2%). The calibration plot showed good agreement between predicted risk and observed incidence of preterm PE, with a slope of 0.983 (95% CI, 0.846-1.120) and an intercept of 0.154 (95% CI, -0.091 to 0.397). CONCLUSIONS The FMF model is effective in predicting preterm PE in the Spanish population at 11-13 weeks' gestation. This method of screening is feasible to implement in routine clinical practice, but it should be accompanied by a robust audit and monitoring system, in order to maintain high-quality screening. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
5
|
Gil MM, Rodríguez-Fernández M, Elger T, Akolekar R, Syngelaki A, De Paco Matallana C, Molina FS, Gallardo Arocena M, Chaveeva P, Persico N, Accurti V, Kagan KO, Prodan N, Cruz J, Nicolaides KH. Risk of fetal loss after chorionic villus sampling in twin pregnancy derived from propensity score matching analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2022; 59:162-168. [PMID: 34845786 DOI: 10.1002/uog.24826] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 11/15/2021] [Accepted: 11/18/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVE To estimate the risk of fetal loss associated with chorionic villus sampling (CVS) in twin pregnancy, using propensity score analysis. METHODS This was a multicenter cohort study of women with twin pregnancy undergoing ultrasound examination at 11-13 weeks' gestation, performed in eight fetal medicine units in which the leadership were trained at the Harris Birthright Research Centre for Fetal Medicine in London, UK, and in which the protocols for screening, invasive testing and pregnancy management are similar. The risk of death of at least one fetus was compared between pregnancies that had and those that did not have CVS, after propensity score matching (1:1 ratio). This procedure created two comparable groups by balancing the maternal and pregnancy characteristics that lead to CVS being performed, similar to how randomization operates in a randomized clinical trial. RESULTS The study population of 8581 twin pregnancies included 445 that had CVS. Death of one or two fetuses at any stage during pregnancy occurred in 11.5% (51/445) of pregnancies in the CVS group and in 6.3% (515/8136) in the non-CVS group (P < 0.001). The propensity score algorithm matched 258 cases that had CVS with 258 non-CVS cases; there was at least one fetal loss in 29 (11.2%) cases in the CVS group and in 35 (13.6%) cases in the matched non-CVS group (odds ratio (OR), 0.81; 95% CI, 0.48-1.35; P = 0.415). However, there was a significant interaction between the risk of fetal loss after CVS and the background risk of fetal loss; when the background risk was higher, the risk of fetal loss after CVS decreased (OR, 0.46; 95% CI, 0.23-0.90), while, in pregnancies with a lower background risk of fetal loss, the risk of fetal loss after CVS increased (OR, 2.45; 95% CI, 0.95-7.13). The effects were statistically significantly different (P-value of the interaction = 0.005). For a pregnancy in which the background risk of fetal loss was about 6% (the same as in our non-CVS population), there was no change in the risk of fetal loss after CVS, but, when the background risk was more than 6%, the posterior risk was paradoxically reduced, and when the background risk was less than 6%, the posterior risk increased exponentially; for example, if the background risk of fetal loss was 2.0%, the relative risk was 2.8 and the posterior risk was 5.6%. CONCLUSION In twin pregnancy, after accounting for the risk factors that lead to both CVS and spontaneous fetal loss and confining the analysis to pregnancies at lower prior risk, CVS seems to increase the risk of fetal loss by about 3.5% above the patient's background risk. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
6
|
Elger T, Akolekar R, Syngelaki A, De Paco Matallana C, Molina FS, Gallardo Arozena M, Chaveeva P, Persico N, Accurti V, Kagan KO, Prodan N, Cruz J, Nicolaides KH. Fetal loss after chorionic villus sampling in twin pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2021; 58:48-55. [PMID: 34038977 DOI: 10.1002/uog.23694] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/12/2021] [Accepted: 05/17/2021] [Indexed: 06/12/2023]
Abstract
OBJECTIVE To estimate the chorionic villus sampling (CVS)-related risk of fetal loss in twin pregnancy after adjustment for chorionicity, nuchal translucency thickness (NT), intertwin discordance in crown-rump length (CRL), maternal demographic characteristics and serum pregnancy-associated plasma protein-A (PAPP-A) and free β-human chorionic gonadotropin (β-hCG). METHODS This was a multicenter study from eight fetal medicine units in which the leadership were trained at the Harris Birthright Research Centre for Fetal Medicine in London, UK, and in which the protocols for screening, invasive testing and pregnancy management are similar. Data were obtained prospectively from women with twin pregnancy undergoing routine ultrasound examination at 11-13 weeks' gestation. Multivariable logistic regression analysis with backward stepwise elimination was used to examine whether CVS provided a significant independent contribution to the prediction of risk of fetal loss after adjusting for maternal and pregnancy characteristics, including maternal age, racial origin and weight, method of conception, smoking status, parity, chorionicity, intertwin discordance in CRL, fetal NT ≥ 95th percentile and free β-hCG and PAPP-A multiples of the median. Similarly, within the CVS group, multivariable logistic regression analysis was used to investigate the effect of the number of intrauterine needle insertions and size of the needle on the risk of fetal loss. RESULTS The study population of 8581 twin pregnancies undergoing ultrasound examination at 11-13 weeks' gestation included 316 dichorionic and 129 monochorionic twins that had CVS. First, in twin pregnancies undergoing CVS, compared to those not undergoing CVS, there was a 2-fold increased risk of fetal loss at < 24 weeks' gestation and of loss at any stage in pregnancy. Second, the factors providing a significant independent contribution to the prediction of miscarriage or fetal loss in twin pregnancy were increased maternal weight, black racial origin, monochorionicity, and more so monoamnionicity, large intertwin discordance in CRL and increased fetal NT, and, in the case of fetal loss at any stage, there was also a contribution from assisted conception and low serum PAPP-A. Third, after adjustment for maternal and pregnancy characteristics, CVS did not provide a significant contribution to the risk of fetal loss. Fourth, in twin pregnancies that had CVS, there was no significant contribution to fetal loss from the number of intrauterine needle insertions or needle size. CONCLUSION The 2-fold increased risk of fetal loss following CVS in twin pregnancy can, to a great extent, be explained by maternal and pregnancy characteristics rather than the invasive procedure itself. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
7
|
Gil MM, Molina FS, Rodríguez‐Fernández M, Delgado JL, Carrillo MP, Jani J, Plasencia W, Stratieva V, Maíz N, Carretero P, Lismonde A, Chaveeva P, Burgos J, Santacruz B, Zamora J, De Paco Matallana C. New approach for estimating risk of miscarriage after chorionic villus sampling. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:656-663. [PMID: 32281125 PMCID: PMC7984173 DOI: 10.1002/uog.22041] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2019] [Revised: 03/07/2020] [Accepted: 03/22/2020] [Indexed: 06/08/2023]
Abstract
OBJECTIVE To estimate the risk of miscarriage associated with chorionic villus sampling (CVS). METHODS This was a retrospective cohort study of women attending for routine ultrasound examination at 11 + 0 to 13 + 6 weeks' gestation at one of eight fetal-medicine units in Spain, Belgium and Bulgaria, between July 2007 and June 2018. Two populations were included: (1) all singleton pregnancies undergoing first-trimester assessment at Hospital Clínico Universitario Virgen de la Arrixaca in Murcia, Spain, that did not have CVS (non-CVS group); and (2) all singleton pregnancies that underwent CVS following first-trimester assessment at one of the eight participating centers (CVS group). We excluded pregnancies diagnosed with genetic anomalies or major fetal defects before or after birth, those that resulted in termination and those that underwent amniocentesis later in pregnancy. We used propensity score (PS) matching analysis to estimate the association between CVS and miscarriage. We compared the risk of miscarriage of the CVS and non-CVS groups after PS matching (1:1 ratio). This procedure creates two comparable groups balancing the maternal and pregnancy characteristics that are associated with CVS, in a similar way to that in which randomization operates in a randomized clinical trial. RESULTS The study population consisted of 22 250 pregnancies in the non-CVS group and 3613 in the CVS group. The incidence of miscarriage in the CVS group (2.1%; 77/3613) was significantly higher than that in the non-CVS group (0.9% (207/22 250); P < 0.0001). The PS algorithm matched 2122 CVS with 2122 non-CVS cases, of which 40 (1.9%) and 55 (2.6%) pregnancies in the CVS and non-CVS groups, respectively, resulted in a miscarriage (odds ratio (OR), 0.72 (95% CI, 0.48-1.10); P = 0.146). We found a significant interaction between the risk of miscarriage following CVS and the risk of aneuploidy, suggesting that the effect of CVS on the risk of miscarriage differs depending on background characteristics. Specifically, when the risk of aneuploidy is low, the risk of miscarriage after CVS increases (OR, 2.87 (95% CI, 1.13-7.30)) and when the aneuploidy risk is high, the risk of miscarriage after CVS is paradoxically reduced (OR, 0.47 (95% CI, 0.28-0.76)), presumably owing to prenatal diagnosis and termination of pregnancies with major aneuploidies that would otherwise have resulted in spontaneous miscarriage. For example, in a patient in whom the risk of aneuploidy is 1 in 1000 (0.1%), the risk of miscarriage after CVS will increase to 0.3% (0.2 percentage points higher). CONCLUSIONS The risk of miscarriage in women undergoing CVS is about 1% higher than that in women who do not have CVS, although this excess risk is not solely attributed to the invasive procedure but, to some extent, to the demographic and pregnancy characteristics of the patients. After accounting for these risk factors and confining the analysis to low-risk pregnancies, CVS seems to increase the risk of miscarriage by about three times above the patient's background risk. Although this is a substantial increase in relative terms, in pregnancies without risk factors for miscarriage, the risk of miscarriage after CVS remains low and similar to, or slightly higher than, that in the general population. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
8
|
Tan MY, Syngelaki A, Poon LC, Rolnik DL, O'Gorman N, Delgado JL, Akolekar R, Konstantinidou L, Tsavdaridou M, Galeva S, Ajdacka U, Molina FS, Persico N, Jani JC, Plasencia W, Greco E, Papaioannou G, Wright A, Wright D, Nicolaides KH. Screening for pre-eclampsia by maternal factors and biomarkers at 11-13 weeks' gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 52:186-195. [PMID: 29896812 DOI: 10.1002/uog.19112] [Citation(s) in RCA: 199] [Impact Index Per Article: 33.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 05/04/2018] [Indexed: 05/07/2023]
Abstract
OBJECTIVE To examine the performance of screening for early, preterm and term pre-eclampsia (PE) at 11-13 weeks' gestation by maternal factors and combinations of mean arterial pressure (MAP), uterine artery (UtA) pulsatility index (PI), serum placental growth factor (PlGF) and serum pregnancy-associated plasma protein-A (PAPP-A). METHODS The data for this study were derived from three previously reported prospective non-intervention screening studies at 11 + 0 to 13 + 6 weeks' gestation in a combined total of 61 174 singleton pregnancies, including 1770 (2.9%) that developed PE. Bayes' theorem was used to combine the prior distribution of gestational age at delivery with PE, obtained from maternal characteristics, with various combinations of biomarker multiples of the median (MoM) values to derive patient-specific risks of delivery with PE at < 37 weeks' gestation. The performance of such screening was estimated. RESULTS In pregnancies that developed PE, compared to those without PE, the MoM values of UtA-PI and MAP were increased and those of PAPP-A and PlGF were decreased, and the deviation from normal was greater for early than late PE for all four biomarkers. Combined screening by maternal factors, UtA-PI, MAP and PlGF predicted 90% of early PE, 75% of preterm PE and 41% of term PE, at a screen-positive rate of 10%; inclusion of PAPP-A did not improve the performance of screening. The performance of screening depended on the racial origin of the women; on screening by a combination of maternal factors, MAP, UtA-PI and PlGF and using a risk cut-off of 1 in 100 for PE at < 37 weeks in Caucasian women, the screen-positive rate was 10% and detection rates for early, preterm and term PE were 88%, 69% and 40%, respectively. With the same method of screening and risk cut-off in women of Afro-Caribbean racial origin, the screen-positive rate was 34% and detection rates for early, preterm and term PE were 100%, 92% and 75%, respectively. CONCLUSION Screening by maternal factors and biomarkers at 11-13 weeks' gestation can identify a high proportion of pregnancies that develop early and preterm PE. © 2018 Crown copyright. Ultrasound in Obstetrics & Gynecology © 2018 ISUOG.
Collapse
|
9
|
Tan MY, Poon LC, Rolnik DL, Syngelaki A, de Paco Matallana C, Akolekar R, Cicero S, Janga D, Singh M, Molina FS, Persico N, Jani JC, Plasencia W, Greco E, Papaioannou G, Wright D, Nicolaides KH. Prediction and prevention of small-for-gestational-age neonates: evidence from SPREE and ASPRE. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 52:52-59. [PMID: 29704277 DOI: 10.1002/uog.19077] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Accepted: 04/07/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVES To examine the effect of first-trimester screening for pre-eclampsia (PE) on the prediction of delivering a small-for-gestational-age (SGA) neonate and the effect of prophylactic use of aspirin on the prevention of SGA. METHODS The data for this study were derived from two multicenter studies. In SPREE, we investigated the performance of screening for PE by a combination of maternal characteristics and biomarkers at 11-13 weeks' gestation. In ASPRE, women with a singleton pregnancy identified by combined screening as being at high risk for preterm PE (> 1 in 100) participated in a trial of aspirin (150 mg/day from 11-14 until 36 weeks' gestation) compared to placebo. In this study, we used the data from the ASPRE trial to estimate the effect of aspirin on the incidence of SGA with birth weight < 10th , < 5th and < 3rd percentile for gestational age. We also used the data from SPREE to estimate the proportion of SGA in the pregnancies with a risk for preterm PE of > 1 in 100. RESULTS In SPREE, screening for preterm PE by a combination of maternal factors, mean arterial pressure, uterine artery pulsatility index and serum placental growth factor identified a high-risk group that contained about 46% of SGA neonates < 10th percentile born at < 37 weeks' gestation (preterm) and 56% of those born at < 32 weeks (early); the overall screen-positive rate was 12.2% (2014 of 16 451 pregnancies). In the ASPRE trial, use of aspirin reduced the overall incidence of SGA < 10th percentile by about 40% in babies born at < 37 weeks' gestation and by about 70% in babies born at < 32 weeks; in babies born at ≥ 37 weeks, aspirin did not have a significant effect on incidence of SGA. The aspirin-related decrease in incidence of SGA was mainly due to its incidence decreasing in pregnancies with PE, for which the decrease was about 70% in babies born at < 37 weeks' gestation and about 90% in babies born at < 32 weeks. On the basis of these results, it was estimated that first-trimester screening for preterm PE and use of aspirin in the high-risk group would potentially reduce the incidence of preterm and early SGA by about 20% and 40%, respectively. CONCLUSION First-trimester screening for PE by the combined test identifies a high proportion of cases of preterm SGA that can be prevented by the prophylactic use of aspirin. © 2018 Crown copyright. Ultrasound in Obstetrics & Gynecology © 2018 ISUOG.
Collapse
|
10
|
Massó P, Rus G, Molina FS. Safety of elastography in fetal medicine: preliminary study on hypoacusis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 50:660-661. [PMID: 28150442 DOI: 10.1002/uog.17429] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Revised: 01/24/2017] [Accepted: 01/27/2017] [Indexed: 06/06/2023]
|
11
|
Rolnik DL, Wright D, Poon LCY, Syngelaki A, O'Gorman N, de Paco Matallana C, Akolekar R, Cicero S, Janga D, Singh M, Molina FS, Persico N, Jani JC, Plasencia W, Papaioannou G, Tenenbaum-Gavish K, Nicolaides KH. ASPRE trial: performance of screening for preterm pre-eclampsia. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 50:492-495. [PMID: 28741785 DOI: 10.1002/uog.18816] [Citation(s) in RCA: 215] [Impact Index Per Article: 30.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Accepted: 07/19/2017] [Indexed: 05/07/2023]
Abstract
OBJECTIVE To examine the performance of screening for preterm and term pre-eclampsia (PE) in the study population participating in the ASPRE (Combined Multimarker Screening and Randomized Patient Treatment with Aspirin for Evidence-Based Preeclampsia Prevention) trial. METHODS This was a prospective first-trimester multicenter study on screening for preterm PE in 26 941 singleton pregnancies by means of an algorithm that combines maternal factors, mean arterial pressure, uterine artery pulsatility index and maternal serum pregnancy-associated plasma protein-A and placental growth factor at 11-13 weeks' gestation. Eligible women with an estimated risk for preterm PE of > 1 in 100 were invited to participate in a double-blind trial of aspirin (150 mg per day) vs placebo from 11-14 until 36 weeks' gestation, which showed that, in the aspirin group, the incidence of preterm PE was reduced by 62%. In the screened population, the detection rates (DRs) and false-positive rates (FPRs) for delivery with PE < 37 and ≥ 37 weeks were estimated after adjustment for the effect of aspirin in those receiving this treatment. We excluded 1144 (4.2%) pregnancies because of loss to follow-up or study withdrawal (n = 716), miscarriage (n = 243) or termination (n = 185). RESULTS The study population of 25 797 pregnancies included 180 (0.7%) cases of preterm PE, 450 (1.7%) of term PE and 25 167 (97.6%) without PE. In combined first-trimester screening for preterm PE with a risk cut-off of 1 in 100, the DR was 76.7% (138/180) for preterm PE and 43.1% (194/450) for term PE, at screen-positive rate of 10.5% (2707/25 797) and FPR of 9.2% (2375/25 797). CONCLUSION The performance of screening in the ASPRE study was comparable with that of a study of approximately 60 000 singleton pregnancies used for development of the algorithm; in that study, combined screening detected 76.6% of cases of preterm PE and 38.3% of term PE at a FPR of 10%. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
12
|
O'Gorman N, Wright D, Poon LC, Rolnik DL, Syngelaki A, Wright A, Akolekar R, Cicero S, Janga D, Jani J, Molina FS, de Paco Matallana C, Papantoniou N, Persico N, Plasencia W, Singh M, Nicolaides KH. Accuracy of competing-risks model in screening for pre-eclampsia by maternal factors and biomarkers at 11-13 weeks' gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2017; 49:751-755. [PMID: 28067011 DOI: 10.1002/uog.17399] [Citation(s) in RCA: 153] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 01/03/2017] [Accepted: 01/03/2017] [Indexed: 06/06/2023]
Abstract
OBJECTIVE To examine the diagnostic accuracy of a previously developed model for prediction of pre-eclampsia (PE) by a combination of maternal factors and biomarkers at 11-13 weeks' gestation. METHODS This was a prospective first-trimester multicenter study of screening for PE in 8775 singleton pregnancies. A previously published algorithm was used for the calculation of patient-specific risk of PE in each individual. The detection rates (DRs) and false-positive rates (FPRs) for delivery with PE < 32, < 37 and ≥ 37 weeks were estimated and compared with those for the dataset used for development of the algorithm. RESULTS In the study population, 239 (2.7%) cases developed PE, of which 17 (0.2%), 59 (0.7%) and 180 (2.1%) developed PE < 32, < 37 and ≥ 37 weeks, respectively. With combined screening by maternal factors, mean arterial pressure, uterine artery pulsatility index and serum placental growth factor, the DR was 100% (95% CI, 80-100%) for PE < 32 weeks, 75% (95% CI, 62-85%) for PE < 37 weeks and 43% (95% CI, 35-50%) for PE ≥ 37 weeks, at a 10% FPR. These DRs were similar to the estimated rates for the dataset used for development of the model: 89% (95% CI, 79-96%) for PE < 32 weeks, 75% (95% CI, 70-80%) for PE < 37 weeks and 47% (95% CI, 44-51%) for PE ≥ 37 weeks. CONCLUSION Assessment of a combination of maternal factors and biomarkers at 11-13 weeks provides effective first-trimester screening for preterm PE. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
|
13
|
Peralta L, Rus G, Bochud N, Molina FS. Mechanical assessment of cervical remodelling in pregnancy: insight from a synthetic model. J Biomech 2015; 48:1557-65. [PMID: 25766389 DOI: 10.1016/j.jbiomech.2015.02.037] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2015] [Accepted: 02/15/2015] [Indexed: 11/16/2022]
Abstract
During the gestation and the cervical remodelling, several changes occur progressively in the structure of the tissue. An increase in the hydration, disorganisation of collagen network and decrease in elasticity can be observed. The collagen structure disorganisation is particularly complex: collagen fibres turn thicker and more wavy as the gestation progresses in a transition from relatively straight fibres to wavy fibres, while pores between collagen fibres become larger and separated. Shear wave elastography is a promising but not yet fully understood tool to assess these structural changes and the cervix׳s ability to dilate. To this end, a numerical histo-mechanical model is proposed in the present study, which aims at linking variations in the microscopic histo-biomechanical processes with shear wave propagation characteristics. Parametric simulations are carried out for a broad range of mechanical and geometrical parameters. Results show a direct relationship between the histological and morphological changes during pregnancy and the viscoelastic behaviour of the tissue.
Collapse
|
14
|
Molina FS, Gomez LF, Gonzalía DA, Fresneda MD, Padilla MC, Lewi L. Cord transection in monoamniotic twins: use of a 1000-micron fiber with conical tip. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2014; 44:116-118. [PMID: 24493175 DOI: 10.1002/uog.13316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2013] [Revised: 01/09/2014] [Accepted: 01/16/2014] [Indexed: 06/03/2023]
|
15
|
Molina FS, Gómez LF, Florido J, Padilla MC, Nicolaides KH. Quantification of cervical elastography: a reproducibility study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2012; 39:685-689. [PMID: 22173854 DOI: 10.1002/uog.11067] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 11/23/2011] [Indexed: 05/31/2023]
Abstract
OBJECTIVES To assess a new method for numerical quantification of cervical elastography during pregnancy and to evaluate the repeatability of the measurements. METHODS Cervical elastography was carried out twice by a single operator in 112 singleton pregnancies at a median of 21 (range, 12-40) weeks' gestation. In 50 of the cases a second operator performed another elastography measurement. The intraobserver and interobserver repeatability of measurements in different parts of the cervix were assessed using intraclass correlation coefficients with 95% CI and by Bland-Altman analysis. RESULTS There were no statistically significant differences in the elastography measurements made by the same and by two different observers in each area measured, except in the area that receives the force of the transducer directly. The distribution of elastographic measurements obtained in different regions of the cervix demonstrated that the external and superior parts were significantly softer than the internal and inferior parts. CONCLUSION It is possible to provide an objective quantification of elastographic colors in the cervix. The measurements obtained by elastography may be a mere reflection of the force being applied by the transducer to different parts of the cervix. It is too premature to suggest that the measurements of rate-of-change in tissue displacement reflect histological changes that could provide a measure of cervical ripening.
Collapse
|
16
|
Molina FS, Terra R, Carrillo MP, Puertas A, Nicolaides KH. What is the most reliable ultrasound parameter for assessment of fetal head descent? ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2010; 36:493-499. [PMID: 20533441 DOI: 10.1002/uog.7709] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
OBJECTIVES The aims of this study were, first, to establish the agreement between digital and ultrasound assessment of occipital position and, second, to evaluate the repeatability of the measurements of head direction, angle of the middle line, progression distance and angle of progression in women in the second stage of labor. METHODS Digital examination and then transabdominal ultrasound examination was performed on 50 women in the second stage of labor to determine the fetal occipital position. We also obtained three-dimensional (3D) blocks of the fetal head by transperineal sonography, and two experts in 3D ultrasound measured head direction, angle of the middle line, progression distance and angle of progression. Intraclass correlation coefficients with 95% CIs, and Bland-Altman analysis, were used to evaluate intraobserver and interobserver repeatability of measurements. RESULTS The fetal head position, determined by ultrasound examination, was occiput anterior in 33 (66%) cases and occiput lateral in 17 (34%) cases. Vaginal digital examination failed to identify the correct fetal head position by more than 45° in 33 (66%) cases. All four 3D ultrasound measurements were reproducible but the progression angle had the highest intraclass correlation coefficient for the same observer (0.94; 95% CI, 0.90-0.97) and for two different operators (0.84; 95% CI, 0.73-0.91). The progression angle was also the measurement for which smaller limits of agreement (LOA) were found in the Bland-Altman test, performed to calculate the intraobserver (bias 0.9; LOA, - 9.2 to 11.1%) and interobserver (bias 1.5; LOA, - 15.4 to 18.3%) variability. CONCLUSIONS Digital pelvic examination for determining the fetal head position during labor is not accurate. The most reproducible of the 3D measurements for progression of the fetal head in labor is the progression angle.
Collapse
|
17
|
Molina FS, Nicolaides KH, Carvalho JS. Two- and three-dimensional imaging of coarctation shelf in the human fetus. BMJ Case Rep 2009; 2009:bcr2007130294. [PMID: 21687308 DOI: 10.1136/bcr.2007.130294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
18
|
Molina FS, Faro C, Sotiriadis A, Dagklis T, Nicolaides KH. Heart stroke volume and cardiac output by four-dimensional ultrasound in normal fetuses. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 32:181-187. [PMID: 18634132 DOI: 10.1002/uog.5374] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE To establish reference intervals for fetal heart stroke volume and cardiac output with gestation. METHODS Fetal heart ventricular volumes were measured using the four-dimensional (4D) spatiotemporal imaging correlation (STIC) ultrasound technique in 140 normal singleton pregnancies at 12-34 weeks' gestation. The Virtual Organ Computer-aided AnaLysis (VOCAL) technique was used to obtain a sequence of six sections of each ventricular volume in systole and diastole. Each volume was obtained after a 30 degrees rotation from the previous one around a fixed axis extending from the apex of the heart to the point that divides symmetrically each atrioventricular valve. The contour of each ventricle was drawn manually and the 4D volumes of the left and right ventricle in systole and diastole were estimated. The stroke volume for each ventricle was then calculated by subtracting the one in systole from the one in diastole and the cardiac output was calculated by multiplying the stroke volume by the fetal heart rate. In 50 cases the stroke volumes were measured by the same sonographer twice and the intraobserver agreement of measurements was calculated. RESULTS The left and right stroke volume and cardiac output increased exponentially with gestation, from respective mean values of 0.02 mL, 0.01 mL, 2.39 mL/min and 1.80 mL/min at 12 weeks to 0.30 mL, 0.32 mL, 43.46 mL/min and 46.72 mL/min at 20 weeks, and 2.07 mL, 2.67 mL, 284.71 mL/min and 365.99 mL/min at 34 weeks. The ratio of right to left stroke volume increased significantly with gestation from about 0.97 at 12 weeks to 1.13 at 34 weeks. In the Bland-Altman test, the mean percentage difference and 95% limits of intraobserver agreement for left stroke volume and right stroke volume were - 2.1 (-18.4, 14.2)% and - 0.8 (-16.4, 18.0)%, respectively. CONCLUSIONS In normal fetuses the stroke volume and cardiac output increase between 12 and 34 weeks' gestation. The extent to which, in pathological pregnancies, possible deviations in these measurements from normal prove to be useful in the prediction of outcome remains to be determined.
Collapse
|
19
|
Kagan KO, Wright D, Spencer K, Molina FS, Nicolaides KH. First-trimester screening for trisomy 21 by free beta-human chorionic gonadotropin and pregnancy-associated plasma protein-A: impact of maternal and pregnancy characteristics. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 31:493-502. [PMID: 18432600 DOI: 10.1002/uog.5332] [Citation(s) in RCA: 154] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVES To use multiple regression analysis to define the contribution of maternal variables that influence the measured concentration of free beta-human chorionic gonadotropin (beta-hCG) and pregnancy-associated plasma protein-A (PAPP-A), and the interaction between these covariates, in first-trimester biochemical screening for trisomy 21. METHODS This was a multicenter study of prospective screening for trisomy 21 by a combination of fetal nuchal translucency thickness, and maternal serum free beta-hCG and PAPP-A at 11 + 0 to 13 + 6 weeks of gestation. In the pregnancies subsequently found to have trisomy 21 and in those with no obvious chromosomal abnormality, we used multiple regression analysis to account for pregnancy characteristics that influence the measured concentrations of free beta-hCG and PAPP-A. We fitted Gaussian distributions to the distribution of log multiples of the median (MoM) values in trisomy 21 and in unaffected pregnancies. RESULTS There were 491 cases of trisomy 21 and 96 803 chromosomally normal pregnancies. Compared with values in Caucasian women, those who were parous, non-smokers and those who conceived spontaneously, PAPP-A was 57% higher in women of Afro-Caribbean origin, 3% higher in South Asians, 9% higher in East Asians, 2% higher in nulliparous women, 17% lower in smokers and 10% lower in those conceiving by in-vitro fertilization (IVF). Free beta-hCG was 12% higher in women of Afro-Caribbean origin, 9% lower in South Asians, 8% higher in East Asians, 2% higher in nulliparous women, 4% lower in smokers and 9% higher in those conceiving by IVF. In screening for trisomy 21 by maternal age and serum free beta-hCG and PAPP-A the estimated detection rate was 65% for a false-positive rate of 5%. CONCLUSIONS In first-trimester biochemical screening for trisomy 21 it is essential to adjust the measured values of free beta-hCG and PAPP-A for maternal and pregnancy characteristics.
Collapse
|
20
|
Molina FS, Nicolaides KH, Carvalho JS. Two- and three-dimensional imaging of coarctation shelf in the human fetus. Heart 2008; 94:584. [DOI: 10.1136/hrt.2007.130294] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
21
|
Wright D, Kagan KO, Molina FS, Gazzoni A, Nicolaides KH. A mixture model of nuchal translucency thickness in screening for chromosomal defects. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2008; 31:376-383. [PMID: 18383462 DOI: 10.1002/uog.5299] [Citation(s) in RCA: 160] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE Fetal nuchal translucency (NT) thickness increases with crown-rump length (CRL). In screening for chromosomal defects patient-specific risks are derived by multiplying the a priori maternal age-related risk by a likelihood ratio, determined from the deviation of the measured NT from the expected median. To quantify this deviation the measured NT is either subtracted (delta NT) or divided by the expected median (multiple of the median method, MoM). This study examines the validity of these methods. METHODS NT was prospectively measured at 11 + 0 to 13 + 6 weeks in screening for chromosomal defects. The distribution of NT in euploid and chromosomally abnormal fetuses was examined. RESULTS There were 37 078 normal pregnancies and 264 with trisomy 21, 81 with trisomy 18, 38 with trisomy 13 and 27 with Turner syndrome. We found that firstly, contrary to the assumption underlying the delta NT method, the distribution of delta NT changes with CRL and secondly, contrary to the assumption underlying the MoM method the distribution of NT was not Gaussian. Fetal NT followed two distributions, one that was dependent on CRL and one that was independent of CRL. The distribution in which NT increases with CRL was observed in about 95% of euploid fetuses, 5% with trisomy 21, 30% with trisomy 18, 15% with trisomy 13 and 10% with Turner syndrome. The median CRL-independent NT was 2.0 mm for the euploid group and 3.4, 5.5, 4.0 and 7.8 mm for trisomies 21, 18, 13 and Turner syndrome, respectively. CONCLUSIONS The NT thickness in chromosomally normal and abnormal fetuses follows a mixture of a gestation-dependent and gestation-independent distribution.
Collapse
|