1
|
Search for Subsolar-Mass Binaries in the First Half of Advanced LIGO's and Advanced Virgo's Third Observing Run. PHYSICAL REVIEW LETTERS 2022; 129:061104. [PMID: 36018635 DOI: 10.1103/physrevlett.129.061104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 03/18/2022] [Accepted: 06/07/2022] [Indexed: 06/15/2023]
Abstract
We report on a search for compact binary coalescences where at least one binary component has a mass between 0.2 M_{⊙} and 1.0 M_{⊙} in Advanced LIGO and Advanced Virgo data collected between 1 April 2019 1500 UTC and 1 October 2019 1500 UTC. We extend our previous analyses in two main ways: we include data from the Virgo detector and we allow for more unequal mass systems, with mass ratio q≥0.1. We do not report any gravitational-wave candidates. The most significant trigger has a false alarm rate of 0.14 yr^{-1}. This implies an upper limit on the merger rate of subsolar binaries in the range [220-24200] Gpc^{-3} yr^{-1}, depending on the chirp mass of the binary. We use this upper limit to derive astrophysical constraints on two phenomenological models that could produce subsolar-mass compact objects. One is an isotropic distribution of equal-mass primordial black holes. Using this model, we find that the fraction of dark matter in primordial black holes in the mass range 0.2 M_{⊙}<m_{PBH}<1.0 M_{⊙} is f_{PBH}≡Ω_{PBH}/Ω_{DM}≲6%. This improves existing constraints on primordial black hole abundance by a factor of ∼3. The other is a dissipative dark matter model, in which fermionic dark matter can collapse and form black holes. The upper limit on the fraction of dark matter black holes depends on the minimum mass of the black holes that can be formed: the most constraining result is obtained at M_{min}=1 M_{⊙}, where f_{DBH}≡Ω_{DBH}/Ω_{DM}≲0.003%. These are the first constraints placed on dissipative dark models by subsolar-mass analyses.
Collapse
|
2
|
492 CAC Score Correlation Between Artificial Intelligence Augmented Cardiac CT And Expert Human Readers: Early Clinical Experience. J Cardiovasc Comput Tomogr 2022. [DOI: 10.1016/j.jcct.2022.06.103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
3
|
All-sky, all-frequency directional search for persistent gravitational waves from Advanced LIGO’s and Advanced Virgo’s first three observing runs. Int J Clin Exp Med 2022. [DOI: 10.1103/physrevd.105.122001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
4
|
PO-1588 Dosimetric Characteristics of Photoconductive Material for High Energy Beam in Radiation Therapy. Radiother Oncol 2022. [DOI: 10.1016/s0167-8140(22)03552-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
5
|
Baseline Left Atrial Strain is Predictive of Chemotherapy Induced Cardiotoxicity in High-Risk Cancer Patients. Heart Lung Circ 2022. [DOI: 10.1016/j.hlc.2022.06.227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
6
|
Quantitative Plaque Characteristics In End Stage Renal Disease Patients With Severe Complex Coronary Atherosclerosis. J Cardiovasc Comput Tomogr 2021. [DOI: 10.1016/j.jcct.2021.06.267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
7
|
Coronary CT Angiography Predicts Major Adverse Events In Dialysis Dependent End-stage Renal Disease Patients. J Cardiovasc Comput Tomogr 2021. [DOI: 10.1016/j.jcct.2021.06.282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
8
|
Constraints on Cosmic Strings Using Data from the Third Advanced LIGO-Virgo Observing Run. PHYSICAL REVIEW LETTERS 2021; 126:241102. [PMID: 34213926 DOI: 10.1103/physrevd.97.102002] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 05/23/2021] [Indexed: 05/21/2023]
Abstract
We search for gravitational-wave signals produced by cosmic strings in the Advanced LIGO and Virgo full O3 dataset. Search results are presented for gravitational waves produced by cosmic string loop features such as cusps, kinks, and, for the first time, kink-kink collisions. A template-based search for short-duration transient signals does not yield a detection. We also use the stochastic gravitational-wave background energy density upper limits derived from the O3 data to constrain the cosmic string tension Gμ as a function of the number of kinks, or the number of cusps, for two cosmic string loop distribution models. Additionally, we develop and test a third model that interpolates between these two models. Our results improve upon the previous LIGO-Virgo constraints on Gμ by 1 to 2 orders of magnitude depending on the model that is tested. In particular, for the one-loop distribution model, we set the most competitive constraints to date: Gμ≲4×10^{-15}. In the case of cosmic strings formed at the end of inflation in the context of grand unified theories, these results challenge simple inflationary models.
Collapse
|
9
|
Constraints on Cosmic Strings Using Data from the Third Advanced LIGO-Virgo Observing Run. PHYSICAL REVIEW LETTERS 2021; 126:241102. [PMID: 34213926 DOI: 10.1103/physrevlett.126.241102] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 05/23/2021] [Indexed: 06/13/2023]
Abstract
We search for gravitational-wave signals produced by cosmic strings in the Advanced LIGO and Virgo full O3 dataset. Search results are presented for gravitational waves produced by cosmic string loop features such as cusps, kinks, and, for the first time, kink-kink collisions. A template-based search for short-duration transient signals does not yield a detection. We also use the stochastic gravitational-wave background energy density upper limits derived from the O3 data to constrain the cosmic string tension Gμ as a function of the number of kinks, or the number of cusps, for two cosmic string loop distribution models. Additionally, we develop and test a third model that interpolates between these two models. Our results improve upon the previous LIGO-Virgo constraints on Gμ by 1 to 2 orders of magnitude depending on the model that is tested. In particular, for the one-loop distribution model, we set the most competitive constraints to date: Gμ≲4×10^{-15}. In the case of cosmic strings formed at the end of inflation in the context of grand unified theories, these results challenge simple inflationary models.
Collapse
|
10
|
Three-dimensional myocardial strain for the prediction of clinical events in patients with successfully reperfused ST-segment elevation myocardial infarction. Eur Heart J Cardiovasc Imaging 2021. [DOI: 10.1093/ehjci/jeaa356.156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: None.
Background/Introduction
Two-dimensional (2D) myocardial strain analysis can be used to evaluate the prognosis of patients with acute myocardial infarction and has comparable predictive power as conventional echocardiographic parameters such as left ventricular ejection fraction (LV EF). Three-dimensional (3D) myocardial strain analysis is also expected to have similar clinical usefulness and overcome several inherent limitations of 2D strain analysis. However, no large-scale studies have been reported to date.
Purpose
We aimed to clarify the prognostic significance of 3D strain analysis in patients with ST-segment elevation myocardial infarction (STEMI) who are most likely to benefit from 3D strain analysis.
Methods
Patients who underwent successful revascularization for STEMI from June 2011 to April 2017 were retrospectively recruited. In addition to conventional echocardiographic parameters, 3D global area strain (GAS), 3D global longitudinal strain (GLS), as well as 2D GLS were obtained.
To evaluate the clinical outcomes, we constructed a composite outcome consisting of all-cause death or re-hospitalisation due to acute decompensation of heart failure.
Results
From June 2011 to April 2017, 632 patients were retrospectively recruited in our hospital. Of these patients, 545 patients (86.2%) had a reliable 3D strain analysis. The clinical course of each patient was followed up for a maximum of 96 months (median 49.5 months). During follow-up periods, 55 (10.1%) among 545 patients experienced the composite outcome of all-cause death or re-hospitalisation due to acute decompensation of heart failure. Patients with adverse events were older, had more underlying diseases such as obesity, dyslipidemia, previous history of stroke, or chronic kidney disease. (all, p < 0.05) LV EF was significantly lower, while 2D GLS, 3D GLS, and 3D GAS were significantly higher in patients with poor outcomes. (all, p < 0.001) The area under the receiver operating characteristic curve (AUC) values of LV EF, 2D GLS, 3D GLS, and 3D GAS were 0.70, 0.71, 0.67, and 0.65, respectively. (all, p < 0.05) Kaplan-Meier analysis of composite outcomes based on the best cut-off values of each parameter demonstrated similar results. (Figure 1) In the Cox proportional hazard model, the hazard ratios of LV EF, 2D GLS, and 3D GLS were 3.0, 5.5, and 2.0, respectively. (all, p < 0.05) The maximum likelihood-ratio test was performed to evaluate the additional prognostic value of 2D GLS or 3D GLS over the basic prognostic model consisting of baseline clinical characteristics and LV EF, and the likelihood ratio was 15.9 for 2D GLS (p < 0.001) and 1.49 for 3D GLS (p = 0.22).
Conclusion(s)
3D strain could be reliably measured in the majority of the patients and had a significant prognostic value. However, the predictive power of the 3D strain was lower than that of the 2D strain. The clinical implications of 3D strain indices should be investigated further.
Abstract Figure.
Collapse
|
11
|
GW190521: A Binary Black Hole Merger with a Total Mass of 150 M_{⊙}. PHYSICAL REVIEW LETTERS 2020; 125:101102. [PMID: 32955328 DOI: 10.1103/physrevlett.125.101102] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/19/2020] [Accepted: 07/09/2020] [Indexed: 06/08/2023]
Abstract
On May 21, 2019 at 03:02:29 UTC Advanced LIGO and Advanced Virgo observed a short duration gravitational-wave signal, GW190521, with a three-detector network signal-to-noise ratio of 14.7, and an estimated false-alarm rate of 1 in 4900 yr using a search sensitive to generic transients. If GW190521 is from a quasicircular binary inspiral, then the detected signal is consistent with the merger of two black holes with masses of 85_{-14}^{+21} M_{⊙} and 66_{-18}^{+17} M_{⊙} (90% credible intervals). We infer that the primary black hole mass lies within the gap produced by (pulsational) pair-instability supernova processes, with only a 0.32% probability of being below 65 M_{⊙}. We calculate the mass of the remnant to be 142_{-16}^{+28} M_{⊙}, which can be considered an intermediate mass black hole (IMBH). The luminosity distance of the source is 5.3_{-2.6}^{+2.4} Gpc, corresponding to a redshift of 0.82_{-0.34}^{+0.28}. The inferred rate of mergers similar to GW190521 is 0.13_{-0.11}^{+0.30} Gpc^{-3} yr^{-1}.
Collapse
|
12
|
DNA barcoding of pear psyllids (Hemiptera: Psylloidea: Psyllidae), a tale of continued misidentifications. BULLETIN OF ENTOMOLOGICAL RESEARCH 2020; 110:521-534. [PMID: 32037992 DOI: 10.1017/s0007485320000012] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Pear psyllids (Hemiptera: Psylloidea: Psyllidae: Cacopsylla spp.) belong to the most serious pests of pear (Pyrus spp.). They damage pear trees by excessive removal of phloem sap, by soiling the fruits with honeydew which, in turn, provides a substrate for sooty mould, and by transmission of Candidatus Phytoplasma spp., the causal agents of the pear decline disease. The morphological similarity, the presence of seasonal dimorphism that affects adult colour, size and wing morphology and uncritical use of species names, led to much confusion in the taxonomy of pear psyllids. As a result, pear psyllids have been frequently misidentified. Many of the entries attributed to Cacopsylla pyricola and other species in the GenBank are misidentifications which led to additional, unnecessary confusion. Here we analysed DNA barcodes of 11 pear psyllid species from eastern Asia, Europe and Iran using four mitochondrial gene fragments (COI 658 bp, COI 403 bp, COI-tRNAleu-COII 580 bp and 16S rDNA 452 bp). The efficiency of identification was notably high and considerable barcoding gaps were observed in all markers. Our results confirm the synonymies of the seasonal forms of Cacopsylla jukyungi ( = C. cinereosignata, winter form) and C. maculatili ( = C. qiuzili, summer form) previously suggested based on morphology. Some previous misidentifications (C. chinensis from China, Japan and Korea = misidentification of C. jukyungi; C. pyricola and C. pyrisuga from East Asia = misidentification of C. jukyungi and C. burckhardti, respectively; C. pyricola from Iran = misidentification of C. bidens, C. pyri and Cacopsylla sp.) are also corrected. There is no evidence for the presence of European pear psyllid species in East Asia.
Collapse
|
13
|
744 A study of skin-age analysis method using five parameters and skin characteristics of subjects using First Care Activation Serum for long-term period. J Invest Dermatol 2020. [DOI: 10.1016/j.jid.2020.03.758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
14
|
0672 The Effect Of Armodafinil On Sleep Spindles In Obstructive Sleep Apnea: Secondary Analysis Of A Randomized Placebo-controlled Trial. Sleep 2020. [DOI: 10.1093/sleep/zsaa056.668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Introduction
Armodafinil has been trialed in OSA patients to promote wakefulness and simulated driving performance. We have previously completed a 6-month trial of 150mg of armodafinil vs placebo in moderate-severe OSA patients not using CPAP (ACTRN# 12611000847910) observing that participants on armodafinil learned to perform better across a 90-minute driving simulator task faster than those on placebo. It is possible that this reduction in time-on-task decrement may have been due to increased learning on armodafinil.
Sleep spindles have previously been implicated in procedural learning and neurobehavioral performance. We hypothesized that armodafinil increases sleep spindle events during NREM sleep to enhance learning.
Methods
Sixty-three overweight severe OSA patients (mean BMI: 32.3kg/m2 (26.1-42.5); age 53.1 years (28-71), 52 males) underwent overnight in-lab polysomnography at baseline (0 months) and at a 6-month follow-up. All-night EEG signals were analyzed using a previously validated automated spindle detection algorithm. EEG recordings were visually inspected by an experienced sleep physician (LE), who was blinded to drug allocation. To minimize the likelihood of type 1 error we selected three key spindle variables detected at Cz for analysis of change between 0 and 6 months: 1) total number of spindle events (11-16 Hz) in NREM sleep 2) density of slow spindles (≥11 to ≤ 13Hz) per minute of NREM sleep, and 3) fast spindle density in NREM (>13 to ≤ 16Hz).
Results
The change in total spindle count in NREM sleep (armodafinil=11.6 vs Placebo =-17.1, p=0.57), fast spindle density (armodafinil=0.06 vs Placebo =-0.02, p=0.63) and slow spindle density (armodafinil=-0.00 vs. Placebo =-0.03, p=0.74) were not increased by armodafinil.
Conclusion
If armodafinil enhances simulated driving performance in a way that suppresses time-on-task effects it does not appear to be through a sleep spindle enhancing mechanism. Armodafinil is probably not a pharmacological method of enhancing sleep spindles.
Support
World Sleep Society (International Sleep Research Training Program)CIRUS, Centre for Sleep and Chronobiology, Woolcock Institute of Medical Research, University of Sydney
Collapse
|
15
|
0669 The Effects Of Continuous Positive Airway Pressure Therapy In Moderate To Severe Obstructive Sleep Apnea: A High-density EEG Study. Sleep 2020. [DOI: 10.1093/sleep/zsaa056.665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
A previous high-density electroencephalography (EEG) investigation in asymptomatic OSA showed regional deficits in sleep EEG power particularly slow wave activity (SWA) during NREM sleep in the parietal region. It is unclear whether treatment with CPAP can reverse local sleep EEG abnormalities in OSA, and whether any recovery is related to improvement in sleep-dependent memory consolidation.
Methods
Fifteen male participants (age 50.4±6.5yrs, AHI 51.7±23.5/h) with moderate-severe OSA (AHI>15/h) underwent overnight polysomnography with 256-channel high-density EEG at baseline and following 3 months of CPAP therapy. A word paired associates declarative memory task was administered before and after sleep. After artefact removal, spectral analysis was performed for all channels. Topographical power maps were calculated for standard frequency ranges for NREM sleep (164 channels within a 0.57 radius from the vertex). Maps were compared using both absolute and normalized power (z-scores computed for each subject) and differences between baseline and treatment were determined by statistical nonparametric mapping.
Results
In 11 CPAP compliant patients (intolerant of CPAP [n=3]/high-density EEG [n=1]), analysis of polysomnographic variables showed that total sleep time did not differ but N1 (baseline vs. treatment: 66.9 vs. 39.5 mins,p=0.008) and N2 (195.0 vs. 150.6 mins,p=0.002) sleep was lower and N3 (89.8 vs. 128.7 mins,p=0.003) was higher after CPAP. Topographic analysis of high-density EEG data revealed a regional increase in SWA (1-4.5Hz) EEG power during N3 sleep in a cluster of electrodes overlying the centro-parietal cortex (cluster mean t-value=2.87,p=0.02). The change in overnight declarative memory consolidation (% recognition) after CPAP was significantly correlated with the change in slow spindle frequency activity in frontal regions (cluster mean r=0.875,p=0.003).
Conclusion
CPAP treatment may enhance localised deficits in sleep EEG activity in OSA, and specific regional recovery may translate to memory improvements in the short-term. These data also highlight the potential for long-term therapeutic effects on cognitive outcomes in OSA.
Support
Collapse
|
16
|
Prospects for observing and localizing gravitational-wave transients with Advanced LIGO, Advanced Virgo and KAGRA. LIVING REVIEWS IN RELATIVITY 2020; 23:3. [PMID: 33015351 PMCID: PMC7520625 DOI: 10.1007/s41114-020-00026-9] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 05/27/2020] [Indexed: 05/05/2023]
Abstract
We present our current best estimate of the plausible observing scenarios for the Advanced LIGO, Advanced Virgo and KAGRA gravitational-wave detectors over the next several years, with the intention of providing information to facilitate planning for multi-messenger astronomy with gravitational waves. We estimate the sensitivity of the network to transient gravitational-wave signals for the third (O3), fourth (O4) and fifth observing (O5) runs, including the planned upgrades of the Advanced LIGO and Advanced Virgo detectors. We study the capability of the network to determine the sky location of the source for gravitational-wave signals from the inspiral of binary systems of compact objects, that is binary neutron star, neutron star-black hole, and binary black hole systems. The ability to localize the sources is given as a sky-area probability, luminosity distance, and comoving volume. The median sky localization area (90% credible region) is expected to be a few hundreds of square degrees for all types of binary systems during O3 with the Advanced LIGO and Virgo (HLV) network. The median sky localization area will improve to a few tens of square degrees during O4 with the Advanced LIGO, Virgo, and KAGRA (HLVK) network. During O3, the median localization volume (90% credible region) is expected to be on the order of 10 5 , 10 6 , 10 7 Mpc 3 for binary neutron star, neutron star-black hole, and binary black hole systems, respectively. The localization volume in O4 is expected to be about a factor two smaller than in O3. We predict a detection count of 1 - 1 + 12 ( 10 - 10 + 52 ) for binary neutron star mergers, of 0 - 0 + 19 ( 1 - 1 + 91 ) for neutron star-black hole mergers, and 17 - 11 + 22 ( 79 - 44 + 89 ) for binary black hole mergers in a one-calendar-year observing run of the HLV network during O3 (HLVK network during O4). We evaluate sensitivity and localization expectations for unmodeled signal searches, including the search for intermediate mass black hole binary mergers.
Collapse
|
17
|
P1368 Effect of angiotensin receptor blocker in patients with moderate or severe aortic stenosis: a randomized controlled trial. Eur Heart J Cardiovasc Imaging 2020. [DOI: 10.1093/ehjci/jez319.803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Funding Acknowledgements
This study was supported by grants from Boryung Pharmacy Research Fund.
Background/Introduction: Pathophysiology of aortic stenosis (AS) and several previous studies suggested the potential role of angiotensin receptor blocker (ARB) in patients with AS.
Purpose
We aimed to investigate the effects of Fimasartan, an ARB, on exercise capacity and progression of AS in patients with moderate to severe AS.
Methods
We conducted a prospective, randomized, double-blind, placebo-controlled trial in 32 normotensive or controlled-hypertensive patients with moderate or severe AS. Study participants were randomized to Fimasartan 30 mg to 60 mg daily (n = 14) or placebo (n = 18) for 1 year, and underwent cardiopulmonary exercise test, 6-minute walk test, and echocardiography at 0, 6, and 12 months, with follow-up data available in 29 subjects.
Results
Significant reductions in blood pressures were observed in the Fimasartan group but not in the placebo group. Two of the 14 patients in the Fimasartan group withdrew the study due to mild symptoms probably related with the decreased blood pressure, and one patient decline the study protocol. After the 12-month treatment, the peak oxygen consumption (VO2; the primary outcome) in the Fimasartan group was significantly decreased (from 28.3 ± 5.9 to 25.4 ± 3.8 mL/min/kg, P = 0.021) but not in the placebo group (P for interaction = 0.046) (Figure 1A). The severity of AS showed a gradual progression in both groups, without inter-group differences (mean transaortic pressure; Fimasartan group, +4.0 ± 3.8 mmHg/year; placebo group, +5.3 ± 6.2 mmHg/year; P for interaction = 0.429) (Figure 1B). Parameters of left ventricular systolic and diastolic function did not change in both groups.
Conclusions
The use of ARB impaired exercise capacity in patients with moderate or severe AS, and did not prevent the progression of AS. However, due to the small number of participants, further studies are required to confirm these findings.
Abstract P1368 Figure.
Collapse
|
18
|
P785 Left ventricular geometry and myocardial contractility modulate impact of statins on prognosis in patients with acute heart failure. Eur Heart J Cardiovasc Imaging 2020. [DOI: 10.1093/ehjci/jez319.444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Funding Acknowledgements
N/A
Background/Introduction: The benefit of statins in patients with heart failure (HF) remains controversial and the mechanism of action is largely speculative. We investigated whether survival benefit with statins differs according to left ventricular (LV) geometry and myocardial contractility in acute HF patients.
Methods
We enrolled 1792 acute HF patients receiving statins and 2296 patients not receiving statins admitted from 2009 to 2016. The LV and right ventricular (RV) global longitudinal strain (GLS) was assessed as a measure of myocardial contractility. Patients were classified into 2 groups based on ischemic etiology of HF and further divided into 4 subgroups according to the median values of LV-GLS or RV-GLS. The primary outcome was 5-year all-cause mortality. The study protocol was approved by the ethics committee at each institute and complied with the Declaration of Helsinki. The need for written informed consent was waived.
Results
During the 5-year follow-up, 1740 (40.4%) patients died and they had more unfavorable baseline characteristics. Statin therapy was significantly associated with improved survival in overall patients and in both groups with and without ischemic etiology (all p <0.001). Patients with concentric remodeling/hypertrophy and eccentric hypertrophy demonstrated survival benefit with statin therapy (P = 0.033, 0.004, and 0.008, respectively), while those with normal geometry did not (p = 0.123). In the non-ischemic HF group, survival benefit with statin therapy was confined to patients with low LV-GLS (p = 0.045) or those with low RV-GLS p = 0.003). On the contrary, in ischemic HF group, survival benefit with statin therapy was observed in all patients regardless of the values of LV-GLS or RV-GLS. Significant interactions were present between statin use and diabetes mellitus and IHD (p for interaction = 0.027 and 0.003, respectively) regarding mortality.
Conclusions
LV geometry and myocardial contractility may modulate the effects of statins in patients with acute HF. These echocardiographic measures can provide prognostic information to guide tailored statin treatment in this population. Our findings may also help to develop more well-designed prospective studies, in terms of a more homogenous study population, to confirm survival benefit with statin therapy.
Abstract P785 Figure. Multivariate Cox survival curves
Collapse
|
19
|
Search for Subsolar Mass Ultracompact Binaries in Advanced LIGO's Second Observing Run. PHYSICAL REVIEW LETTERS 2019; 123:161102. [PMID: 31702344 DOI: 10.1103/physrevlett.123.161102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Indexed: 06/10/2023]
Abstract
We present a search for subsolar mass ultracompact objects in data obtained during Advanced LIGO's second observing run. In contrast to a previous search of Advanced LIGO data from the first observing run, this search includes the effects of component spin on the gravitational waveform. We identify no viable gravitational-wave candidates consistent with subsolar mass ultracompact binaries with at least one component between 0.2 M_{⊙}-1.0 M_{⊙}. We use the null result to constrain the binary merger rate of (0.2 M_{⊙}, 0.2 M_{⊙}) binaries to be less than 3.7×10^{5} Gpc^{-3} yr^{-1} and the binary merger rate of (1.0 M_{⊙}, 1.0 M_{⊙}) binaries to be less than 5.2×10^{3} Gpc^{-3} yr^{-1}. Subsolar mass ultracompact objects are not expected to form via known stellar evolution channels, though it has been suggested that primordial density fluctuations or particle dark matter with cooling mechanisms and/or nuclear interactions could form black holes with subsolar masses. Assuming a particular primordial black hole (PBH) formation model, we constrain a population of merging 0.2 M_{⊙} black holes to account for less than 16% of the dark matter density and a population of merging 1.0 M_{⊙} black holes to account for less than 2% of the dark matter density. We discuss how constraints on the merger rate and dark matter fraction may be extended to arbitrary black hole population models that predict subsolar mass binaries.
Collapse
|
20
|
All-sky search for continuous gravitational waves from isolated neutron stars using Advanced LIGO O2 data. Int J Clin Exp Med 2019. [DOI: 10.1103/physrevd.100.024004] [Citation(s) in RCA: 87] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
21
|
308 Beneficial effect of coumestrol on the psychological stress-induced skin barrier dysfunction through inhibition of 11β-hydroxysteroid dehydrogenase type 1. J Invest Dermatol 2019. [DOI: 10.1016/j.jid.2019.03.384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
2018 European Conference on Donor Health and Management. Transfus Med 2019; 29:16-19. [PMID: 30859641 DOI: 10.1111/tme.12589] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 02/08/2019] [Accepted: 02/11/2019] [Indexed: 11/29/2022]
Abstract
The third European Conference on Donor Health and Management (ECDHM) was held in Copenhagen from 5th to 7th September 2018 and was co-organised by the ECDHM committees and European Blood Alliance. This is an international conference with a focus on 'donor health', including donors of blood, organs and other substances of human origin, and remains the only conference focusing exclusively on donor medicine. This overview presents a selection of research topics in relation to iron, the keynote speeches and plenary talks. The keynote speeches cover the epidemiology of donors and recipients, whole-blood donor recruitment and retention and the safety of donors and recipients of plasma and plasma products. Talks from the plenary speakers reviewed modern multi-omic approaches to study red cell quality and the central, perennial question of what motivates a donor to give blood and how can this be encouraged.
Collapse
|
23
|
P2742Does concordance last over years? From training exercise to practice in the SUCCOUR trial. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p2742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
24
|
Cost-effectiveness of alternative changes to a national blood collection service. Transfus Med 2018; 29 Suppl 1:42-51. [PMID: 29767450 PMCID: PMC7379655 DOI: 10.1111/tme.12537] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 04/08/2018] [Accepted: 04/09/2018] [Indexed: 12/04/2022]
Abstract
Objectives To evaluate the cost‐effectiveness of changing opening times, introducing a donor health report and reducing the minimum inter‐donation interval for donors attending static centres. Background Evidence is required about the effect of changes to the blood collection service on costs and the frequency of donation. Methods/Materials This study estimated the effect of changes to the blood collection service in England on the annual number of whole‐blood donations by current donors. We used donors' responses to a stated preference survey, donor registry data on donation frequency and deferral rates from the INTERVAL trial. Costs measured were those anticipated to differ between strategies. We reported the cost per additional unit of blood collected for each strategy versus current practice. Strategies with a cost per additional unit of whole blood less than £30 (an estimate of the current cost of collection) were judged likely to be cost‐effective. Results In static donor centres, extending opening times to evenings and weekends provided an additional unit of whole blood at a cost of £23 and £29, respectively. Introducing a health report cost £130 per additional unit of blood collected. Although the strategy of reducing the minimum inter‐donation interval had the lowest cost per additional unit of blood collected (£10), this increased the rate of deferrals due to low haemoglobin (Hb). Conclusion The introduction of a donor health report is unlikely to provide a sufficient increase in donation frequency to justify the additional costs. A more cost‐effective change is to extend opening hours for blood collection at static centres.
Collapse
|
25
|
705 A study about the importance of constant temperature and humidity system in analyzing skin barrier function. J Invest Dermatol 2018. [DOI: 10.1016/j.jid.2018.03.714] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
26
|
1116 The extract of Ganoderma lucidum inhibits MMP-1 expression through suppression of ERK activation in UVB irradiated dermal fibroblast and skin equivalent model. J Invest Dermatol 2018. [DOI: 10.1016/j.jid.2018.03.1130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
27
|
0452 Intra-individual Stability of Quantitative EEG as a Biomarker in Obstructive Sleep Apnea. Sleep 2018. [DOI: 10.1093/sleep/zsy061.451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
28
|
The robustness of T 2 value as a trabecular structural index at multiple spatial resolutions of 7 Tesla MRI. Magn Reson Med 2018; 80:1949-1961. [PMID: 29656389 DOI: 10.1002/mrm.27202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/09/2018] [Accepted: 03/11/2018] [Indexed: 12/13/2022]
Abstract
PURPOSE To evaluate the robustness of MR transverse relaxation times of trabecular bone from spin-echo and gradient-echo acquisitions at multiple spatial resolutions of 7 T. METHODS The effects of MRI resolutions to T2 and T2* of trabecular bone were numerically evaluated by Monte Carlo simulations. T2 , T2*, and trabecular structural indices from multislice multi-echo and UTE acquisitions were measured in defatted human distal femoral condyles on a 7 T scanner. Reference structural indices were extracted from high-resolution microcomputed tomography images. For bovine knee trabecular samples with intact bone marrow, T2 and T2* were measured by degrading spatial resolutions on a 7 T system. RESULTS In the defatted trabecular experiment, both T2 and T2* values showed strong ( |r| > 0.80) correlations with trabecular spacing and number, at a high spatial resolution of 125 µm3 . The correlations for MR image-segmentation-derived structural indices were significantly degraded ( |r| < 0.50) at spatial resolutions of 250 and 500 µm3 . The correlations for T2* rapidly dropped ( |r| < 0.50) at a spatial resolution of 500 µm3 , whereas those for T2 remained consistently high ( |r| > 0.85). In the bovine trabecular experiments with intact marrow, low-resolution (approximately 1 mm3 , 2 minutes) T2 values did not shorten ( |r| > 0.95 with respect to approximately 0.4 mm3 , 11 minutes) and maintained consistent correlations ( |r| > 0.70) with respect to trabecular spacing (turbo spin echo, 22.5 minutes). CONCLUSION T2 measurements of trabeculae at 7 T are robust with degrading spatial resolution and may be preferable in assessing trabecular spacing index with reduced scan time, when high-resolution 3D micro-MRI is difficult to obtain.
Collapse
|
29
|
Template-free synthesis of monolithic carbon xerogels with hierarchical porosity from resorcinol and formaldehyde via hydrothermal reaction. RSC Adv 2018; 8:21326-21331. [PMID: 35539906 PMCID: PMC9080866 DOI: 10.1039/c8ra02806k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 05/30/2018] [Indexed: 11/21/2022] Open
Abstract
Monolithic carbon xerogels with hierarchical porosity were prepared from resorcinol (R) and formaldehyde (F) via a base-catalysed hydrothermal polycondensation reaction, without a template and supercritical drying. First, an aqueous solution of resorcinol, formaldehyde and sodium carbonate was prepared by varying R/W (25–45) and R/C (1–10k) ratios to produce monolithic RF gels. The reaction was carried out in a pressurized Teflon mould at 100 °C for 6 h to give a co-continuous pore structure via spinodal decomposition and a tenacious gel to avoid supercritical drying. Next, the RF gels were dried for 42 h at 60 °C and another 6 h at 100 °C to produce RF xerogels without cracks, followed by pyrolysis in a tube furnace at 900 °C for 2 h under N2 flow, and then activation at 1000 °C for 2, 4 or 6 h under CO2 flow. Finally, the carbon xerogels were characterized by SEM and N2 adsorption–desorption measurements. Monolithic RF gels were obtained from all combinations of R/W and R/C, but the gels from R/W = 45 exhibited a co-continuous large-pore structure, providing a specific surface area (SSA) of ∼650 m2 g−1, which increased to 3311 m2 g−1 (for R/C = 10k) at 6 h of CO2 activation without exhibiting cracks. N2 isotherms demonstrated that micro- and meso-pores were introduced via activation, forming hierarchical porosity in combination with large pores from spinodal decomposition without using a template. Monolithic porous carbon with hierarchical porosity via a one-step template-free hydrothermal polycondensation reaction with resorcinol and formaldehyde.![]()
Collapse
|
30
|
0557 THE ROLE OF NIGHTLY ZOPICLONE ON OBSTRUCTIVE SLEEP APNEA SEVERITY AND SYMPTOMS IN PEOPLE WITH LOW TO MODERATE RESPIRATORY AROUSAL THRESHOLDS: A RANDOMIZED, DOUBLE-BLIND, PLACEBO-CONTROLLED TRIAL. Sleep 2017. [DOI: 10.1093/sleepj/zsx050.556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
31
|
Comparison of Single-View and Standard Assessment of Global Longitudinal Strain for Diagnosis of Cardiotoxicity. Heart Lung Circ 2017. [DOI: 10.1016/j.hlc.2017.06.482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
32
|
The Strain Learning Curve – Does More Experience Lead to Better Concordance? Heart Lung Circ 2016. [DOI: 10.1016/j.hlc.2016.06.591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
33
|
SU-F-J-136: Impact of Audiovisual Biofeedback On Interfraction Motion Over a Course of Liver Cancer Stereotactic Body Radiotherapy. Med Phys 2016. [DOI: 10.1118/1.4956044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
34
|
EP-1742: The first clinical implementation of audiovisual biofeedback in liver cancer SBRT. Radiother Oncol 2016. [DOI: 10.1016/s0167-8140(16)32993-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
35
|
POST-HARVEST EMBRYO DEVELOPMENT IN GINSENG SEEDS INCREASES DESICCATION SENSITIVITY AND NARROWS THE HYDRATION WINDOW FOR CRYOPRESERVATION. CRYO LETTERS 2016; 37:284-294. [PMID: 27925011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
BACKGROUND Despite its self-pollinating characteristics, Korean ginseng germplasm is mainly maintained in clonal gene banks as there is no defined approach to the long-term conservation of its seed, including the most appropriate stage of embryo development for storage. OBJECTIVE The aim of this study was to reveal the effect of embryo development on desiccation tolerance and cryopreservation success in ginseng seeds. MATERIALS AND METHODS Seeds of Korean ginseng (Panax ginseng C.A. Meyer) at three post-harvest stages (immediately after harvesting and following treatments to enable internal growth of the embryo) were desiccated and cryopreserved. RESULTS The hydration window for the >80% dehiscence and germination of cryopreserved ginseng seeds varied with embryo developmental stage: 3-9% moisture content (MC) for both unpulped and undehisced seeds when the embryo was 0.1 the length of the endosperm, 7-10% MC for dehisced seeds (0.5 embryo:endosperm) and 9-11% MC for seeds with fully developed embryos (0.9 embryo:endosperm). Whilst dried (4-8% moisture content) and undehisced seeds within fruits (unpulped seeds) lost more than half their viability during 1 year's storage at room temperature, cryopreservation enabled germination levels of c. 90%. Overall, 432 accessions of Korean ginseng landraces have been cryopreserved using undehisced seeds with or without fruits. CONCLUSION Post-harvest treatment of Korean ginseng seeds to enable embryo development decreases tolerance of very low MCs, and thus narrows the hydration window for cryopreservation. Fresh-harvested and unpulped seeds that have been dried to c. 5% MC are recommended for long-term cryogenic storage.
Collapse
|
36
|
Surface Collective Modes in the Topological Insulators Bi_{2}Se_{3} and Bi_{0.5}Sb_{1.5}Te_{3-x}Se_{x}. PHYSICAL REVIEW LETTERS 2015; 115:257402. [PMID: 26722943 DOI: 10.1103/physrevlett.115.257402] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Indexed: 06/05/2023]
Abstract
We used low-energy, momentum-resolved inelastic electron scattering to study surface collective modes of the three-dimensional topological insulators Bi_{2}Se_{3} and Bi_{0.5}Sb_{1.5}Te_{3-x}Se_{x}. Our goal was to identify the "spin plasmon" predicted by Raghu and co-workers [Phys. Rev. Lett. 104, 116401 (2010)]. Instead, we found that the primary collective mode is a surface plasmon arising from the bulk, free carriers in these materials. This excitation dominates the spectral weight in the bosonic function of the surface χ^{"}(q,ω) at THz energy scales, and is the most likely origin of a quasiparticle dispersion kink observed in previous photoemission experiments. Our study suggests that the spin plasmon may mix with this other surface mode, calling for a more nuanced understanding of optical experiments in which the spin plasmon is reported to play a role.
Collapse
|
37
|
Static hyoid position and dynamic lateral pharyngeal wall collapse predict OSA severity: Observations based on sleep MRI. Sleep Med 2015. [DOI: 10.1016/j.sleep.2015.02.484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
38
|
Poster session 5The imaging examinationP1097Correlation between visual and quantitative assessment of left ventricle: intra- and inter-observer agreementP1099Incremental prognostic value of late gadolinium-enhanced by cardiac magnetic resonance in patients with heart failureAnatomy and physiology of the heart and great vesselsP1100Left ventricular geometry and diastolic performance in erectile dysfunction patients; a topic of differential arterial stiffness influenceAssessment of diameters, volumes and massP1101Impact of the percutaneous closure of atrial septal defect on the right heart "remodeling"P1102Left Ventricular Mass Indexation in Infants, Children and Adolescents: a Simplified Approach for the Identification of Left Ventricular Hypertrophy in Clinical PracticeP1103Impact of trabecules while quantifying cardiac magnetic resonance exams in patients with systemic right ventricleP1104Detection of subclinical atherosclerosis by carotid intima-media thickness: correlation with leukocytes telomere shorteningAssessments of haemodynamicsP1105Flow redirection towards the left ventricular outflow tract: vortex formation is not affected by variations in atrio-ventricular delayAssessment of systolic functionP1106Reproducibility and feasibility of cardiac MRI feature tracking in Fabry diseaseP1107Normal left ventricular strain values by two-dimensional strain echocardiography; result of normal (normal echocardiographic dimensions and functions in korean people) studyP1108Test-retest repeatability of global strain following st-elevation myocardial infarction - a comparison of tagging and feature trackingP1109Cardiotoxicity induced by tyrosine kinase inhibitors in patients with gastrointestinal stromal tumors (GIST)P1110Finite strain ellipses for the analysis of left ventricular principal strain directions using 3d speckle tracking echocardiographyP1111Antihypertensive therapy reduces time to peak longitudinal strainP1112Right ventricular systolic function as a marker of prognosis after inferior myocardial infarction - 5-year follow-upP1113Is artery pulmonary dilatation related with right but also early left ventricle dysfunction in pulmonary artery hypertension?P1114Right ventricular mechanics changes according to pressure overload increasing, a 2D-speckle tracking echocardiographic evaluationAssessment of diastolic functionP1115Paired comparison of left atrial strain from P-wave to P-wave and R-wave to R-waveP1116Diagnostic role of Tissue Doppler Imaging echocardiographic criteria in obese heart failure with preserved ejection fraction patientsP1117Evaluation of diastolic function of right ventricle in idiopathic pulmonary arterial hypertensionP1118Severity and predictors of diastolic dysfunction in a non-hypertensive non-ischemic cohort of Egyptian patients with documented systemic autoimmune disease; pilot reportP1119correlation between ST segment shift and cardiac diastolic function in patients with acute myocardial infarctionIschemic heart diseaseP1120Computed tomography coronary angiography verSus sTRess cArdiac magneTic rEsonance for the manaGement of sYmptomatic revascularized patients: a cost effectiveness study (STRATEGY study)P1121Utility of transmural myocardial mechanic for early infarct size prediction after primary percutaneous coronary intervention in STEMI patientsP1122Progressive Improvements of the echocardiographic deformation parameters in ST Elevation Myocardial Infarction after five years follow-upP1123Long-term prognostic value of left ventricular dyssynchrony as assessed by cardiac magnetic resonance feature-tracking imaging after a first st-segment elevation myocardial infarctionP1124Differences in mitral annulus remodeling in acute anterior ST elevation and acute inferior ST elevation myocardial infarctionP1125Reduction of microvascular injury using a novel theragnostic ultrasound strategy: a first in men feasibility and safety studyP1126Impact of focused echocardiography in clinical decision of patient presented with st elevation myocardial infarction underwent primary angioplastyHeart valve DiseasesP1127Aortic valve area calculation in aortic stenosis: a comparison among conventional and 3D-transesophageal echocardiography and computed tomographyP1128Myocardial fibrosis and microRNA-21 expression in patients with severe aortic valve stenosis and preserved ejection fraction: a 2D speckle tracking echocardiography, tissutal and plasmatic studyP1129Quantification of calcium amount in a new experimental model: a comparison between calibrated integrated backscatter of ultrasound and computed tomographyP1130Altered diffusion capacity in aortic stenosis: role of the right heartP1131Osteoprotegerin predicts all-cause mortality in calcific aortic stenosis patients with preserved left ventricle ejection fraction in long term observationP1132Mitral regurgitation as a risk factor for pulmonary hypertension in patients with aortic stenosisP1133The relationship between the level of plasma B-type natriuretic peptide and mitral stenosisP1134Aortic regurgitation, left ventricle mechanics and vascular load: a single centre 2d derived-speckle tracking studyP1135Feasibility and reproducibility issues limit the usefulness of quantitative colour Doppler parameters in the assessment of chronic aortic and mitral regurgitation severityP1136Predictors of postoperative outcome in degenerative mitral regurgitationP1137Left ventricular mechanical dyssynchrony in patients with severe mitral regurgitation of rheumatic etiology; three dimensional echocardiography studyP1138Functional mitral regurgitation and left atrial dysfunction concur in determining pulmonary hypertension and functional status in subjects with left ventricular systolic dysfunctionP11393D echocardiography allows more effective quantitative assessment of the severity of functional tricuspid regurgitation than conventional 2D/Doppler echocardiographyP1140Prosthetic valve thrombosis: still a severe disease? 10-years experience in a university hospitalP1141Validity of echocardiography in the hospital course of patients with feverP1142Do baseline 3DTEE characteristics of mitral valve apparatus predict long term result in patients undergoing percutaneous valve repair for degenerative regurgitation?P1143Influence of baseline aortic regurgitation on mitral regurgitation change after transcatheter aortic valve replacement for aortic stenosisP1144Prevalence of echocardiography detected significant valvular regurge in subclinical rheumatic carditis in assiut childrenCardiomyopathiesP1145Can we early detect left ventricular systolic dysfunction in patients with Duchenne muscular dystrophy using global longitudinal strain assessment?P1146Prevalence of isolated papillary muscle hypertrophy in young competitive athletesP1147Troponin release after exercise in patients with hypertrophic cardiomyopathy: associations with clinical and mr imaging characteristicsP1148Atrial fibrillation in hypertrophic cardiomyopathy: can we score the risk?P1149Impact of hypertrophy on multiple layer longitudinal deformation in hypertrophy cardiomyopathy and cardiac amyloidosis compared to controlsP1150Functional evaluation in hypertrophic cardiomyopathy combining cardiopulmonary exercise testing combined with exercise-echocardiographyP1151Refinement of the old diagnostic criteria of left ventricular noncompaction cardiomyopathy (LVNC) based on cardiac magnetic resonance (CMR)P1152Differences of clinical characteristics and outcomes between acute myocarditis with preserved and reduced left ventricular systolic functionP1153Value of longitudinal strain for distinguishing left ventricular non-compaction from idiopathic dilated cardiomyopathyP1154Speed of recovery of left ventricular function is not related to the prognosis of Takotsubo cardiomyopathy. A Portuguese multicentre studyP1155Predictors of in-hospital left ventricular systolic function recovery after admission with takotsubo cardiomyopathy. Portuguese multicentre studyP1156Mid-ventricular takotsubo detected by initial echocardiogram associates with recurrence of takotsubo cardiomyopathy - a portuguese multicentre studySystemic diseases and other conditionsP1157Relations between left ventricle remodelling and expression of angiotensin 2 AT2R1 geneP1158Impact of renal denervation on long-term blood pressure variability and surrogate markers of target organ damage in individuals with drug-resistant arterial hypertensionP1159Greater improvement of coronary artery function, left ventricular deformation and twisting by IL12/23 compared to TNF-a inhibition in psoriasisP1160Advanced glycation end products play a role in adverse LV remodeling following MIP1161Incidence of subclinical myocardial dysfunction in patients with systemic sclerosis and normal left ventricular systolic and diastolic functionP1162Left atrial remodeling and dysfunction occur early in patients with systemic sclerosis and normal left ventricular functionP1163Intrinsic vortex formation : a unique performance indicatorP1164P-wave morphology is unaffected by training-induced biatrial dilatation: a prospective, longitudinal study in healthy athletesP1165Usefulness of transthoracic echocardiography in diagnosis of young patients with ischemic strokeP1166Primary cardiac lymphoma: role of echocardiography in the clinical managementP1167Abnormal echocardiographic findings in cancer patients before chemotherapyMasses, tumors and sources of embolismP1168Three-dimensional transesophageal echocardiography of the left atrial appendage reduces rate of postpone electrical cardioversionP1169Detection of ventricular thrombus by cmr after reperfused st-segment elevation myocardial infarction correlated with echocardiographyP1170Clinical and transthoracic echocardiographic predictors of left atrial appendage thrombus in patients with atrial fibrillationStress echocardiographyP1171Pharmacological stress echocardiography complications: a 4-year single center experienceP1172Myocardial functional and perfusion reserve in type I diabetesP1173Feasibility of incorporating 3D Dobutamine stress echocardiography into routine clinical practiceP1174Right ventricular isovolumic acceleration at rest and during exercise in children after heart transplantP1175Right ventricular systolic and diastolic response to exercise in children after heart transplant -a bicycle exercise studyP1176Determinants of functional capacity in heart failure patients with reduced ejection fractionP1177Handgrip stress echocardiography with emotional component compared to conventional isometric exercise in coronary artery disease diagnosisP1178The relationship between resting transthoracic echocardiography and exercise capacity in patients with paroxysmal atrial fibrillationP1179Correlation between NT-proBNP and selected echocardiography parameters at rest and after exercise in patients with functional ischemic mitral regurgitation qualified for cardiosurgical treatmentReal-time three-dimensional TEEP1180Vena contracta area for severity grading in functional and degenerative mitral regurgitation: A study based on transesophageal 3D colour Doppler in 419 patientsP1181Proximal flow convergence by 3D echocardiography in the evaluation of mitral valve area in rheumatic mitral stenosisP1182Quantification of valve dimensions by transesophageal 3D echocardiography in patients with functional and degenerative mitral regurgitationTissue Doppler and speckle trackingP1183Automatic calculation of left ventricular volume changes over a cardiac cycle from echocardiography images by nonlinear dimensionality reductionP1184Effect of the mitral valve repairs on the left ventricular blood flow formationP1185Quantification of left atrial strain using cardiovascular magnetic resonance. a comparison between hypertrophic cardiomyopathy and healthy controlsP1186The role of early systolic lengthening in patients with non-ST elevation acute coronary syndrome and its relation to syntax scoreP1187Different standard two dimensional strain methods to quantity left ventricular mechanicsP1188Atrial function and electrocardiography caracteristics in sportsmen with or without paroxysmal atrial fibrillationP1189Right ventricular outflow premature contractions induce regional left ventricular dysfunctionP1190Ultrasound guided venous access for pacemaker and defibrillators. Randomized TrialP1191Atrial function analysis correlates with symptoms and quality of life of heart failure patientsP1192The use of tissue doppler echocardiography in myocardial iron overload in patients with thalassaemia majorP1193Independent association between pulse pressure and left ventricular global longitudinal strainP1194Global and regional longitudinal strain identifies the presence of coronary artery disease in patients with suspected reduction of coronary flow reserve and absence of wall motion abnormalitiesP1195Prognostic value of invasive and noninvasive parameters of right ventricular function in patients with pulmonary arterial hypertension receiving specific vasodilator therapyP1196Myocardial deformation analysis to improve arrhythmic risk stratificationP1197Quantitative assessment of regional systolic and diastolic function parameters for detecting prior transient ischemia in normokinetic segmentsP1198Left atrial function in patients with corrected tetralogy of Fallot - a three-dimensional speckle-tracking echocardiographic studyP1199Left atrial ejection force correlates with left atrial strain and volume-based functional properties as assessed by three-dimensional speckle tracking echocardiographyP1200Acute angulation of the aortic arch late after the arterial switch operation for transposition of the great arteries: impact on cardiac mechanicsP1201Circumferential deformation of the ascending thoracic aorta in hypertensive patients by three-dimensional speckle tracking echocardiographyCardiac Magnetic ResonanceP1202The incremental value of cardiac magnetic resonance on diagnosis myocardial infarction and non-obstructed coronary arteriesP1204Reference ranges of global and regional myocardial T1 values derived from MOLLI and shMOLLI at 3TComputed Tomography & Nuclear CardiologyP1205Deformation of the left atrial appendage after percutaneous closure with the Amplatzer cardiac plugP1206Prognostic impact of non-obstructive coronary artery disease on coronary computed tomographic angiography: A single-center study. Eur Heart J Cardiovasc Imaging 2015. [DOI: 10.1093/ehjci/jev275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
39
|
Guideline on the clinical use of apheresis procedures for the treatment of patients and collection of cellular therapy products. Transfus Med 2015; 25:57-78. [PMID: 26013470 DOI: 10.1111/tme.12205] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Revised: 04/20/2015] [Accepted: 04/21/2015] [Indexed: 01/19/2023]
|
40
|
BCSH guideline on the clinical use of apheresis procedures: new changes and future directions. Transfus Med 2015; 25:55-6. [PMID: 25959959 DOI: 10.1111/tme.12203] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2015] [Accepted: 04/20/2015] [Indexed: 11/29/2022]
|
41
|
Robust MR assessment of cerebral blood volume and mean vessel size using SPION-enhanced ultrashort echo acquisition. Neuroimage 2015; 112:382-389. [PMID: 25818683 DOI: 10.1016/j.neuroimage.2015.03.042] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2014] [Revised: 03/13/2015] [Accepted: 03/16/2015] [Indexed: 01/21/2023] Open
Abstract
Intravascular superparamagnetic iron oxide nanoparticles (SPION)-enhanced MR transverse relaxation rates (∆R2(⁎) and ∆R2) are widely used to investigate in vivo vascular parameters, such as the cerebral blood volume (CBV), microvascular volume (MVV), and mean vessel size index (mVSI, ∆R2(⁎)/∆R2). Although highly efficient, regional comparison of vascular parameters acquired using gradient-echo based ∆R2(⁎) is hampered by its high sensitivity to magnetic field perturbations arising from air-tissue interfaces and large vessels. To minimize such demerits, we took advantage of the dual contrast property of SPION and both theoretically and experimentally verified the direct benefit of replacing gradient-echo based ∆R2(⁎) measurement with ultra-short echo time (UTE)-based ∆R1 contrast to generate the robust CBV and mVSI maps. The UTE acquisition minimized the local measurement errors from susceptibility perturbations and enabled dose-independent CBV measurement using the vessel/tissue ∆R1 ratio, while independent spin-echo acquisition enabled simultaneous ∆R2 measurement and mVSI calculation of the cortex, cerebellum, and olfactory bulb, which are animal brain regions typified by significant susceptibility-associated measurement errors.
Collapse
|
42
|
Club 35 Poster session 3: Friday 5 December 2014, 08:30-18:00 * Location: Poster area. Eur Heart J Cardiovasc Imaging 2014. [DOI: 10.1093/ehjci/jeu263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
43
|
|
44
|
SU-E-T-175: Evaluation of the Relative Output Ratio for Collimator Jaw and MLC Defined Small Static 6MV Photon Fields. Med Phys 2014. [DOI: 10.1118/1.4888505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
45
|
Ultrafast 3D spin-echo acquisition improves Gadolinium-enhanced MRI signal contrast enhancement. Sci Rep 2014; 4:5061. [PMID: 24863102 PMCID: PMC4034007 DOI: 10.1038/srep05061] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Accepted: 05/07/2014] [Indexed: 11/27/2022] Open
Abstract
Long scan times of 3D volumetric MR acquisitions usually necessitate ultrafast in vivo gradient-echo acquisitions, which are intrinsically susceptible to magnetic field inhomogeneities. This is especially problematic for contrast-enhanced (CE)-MRI applications, where non-negligible T2* effect of contrast agent deteriorates the positive signal contrast and limits the available range of MR acquisition parameters and injection doses. To overcome these shortcomings without degrading temporal resolution, ultrafast spin-echo acquisitions were implemented. Specifically, a multiplicative acceleration factor from multiple spin echoes (×32) and compressed sensing (CS) sampling (×8) allowed highly-accelerated 3D Multiple-Modulation-Multiple-Echo (MMME) acquisition. At the same time, the CE-MRI of kidney with Gd-DOTA showed significantly improved signal enhancement for CS-MMME acquisitions (×7) over that of corresponding FLASH acquisitions (×2). Increased positive contrast enhancement and highly accelerated acquisition of extended volume with reduced RF irradiations will be beneficial for oncological and nephrological applications, in which the accurate in vivo 3D quantification of contrast agent concentration is necessary with high temporal resolution.
Collapse
|
46
|
Gaussian mixture model-based classification of dynamic contrast enhanced MRI data for identifying diverse tumor microenvironments: preliminary results. NMR IN BIOMEDICINE 2013; 26:519-532. [PMID: 23440683 PMCID: PMC3706205 DOI: 10.1002/nbm.2888] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 10/13/2012] [Accepted: 10/15/2012] [Indexed: 06/01/2023]
Abstract
Tumor hypoxia develops heterogeneously, affects radiation sensitivity and the development of metastases. Prognostic information derived from the in vivo characterization of the spatial distribution of hypoxic areas in solid tumors can be of value for radiation therapy planning and for monitoring the early treatment response. Tumor hypoxia is caused by an imbalance between the supply and consumption of oxygen. The tumor oxygen supply is inherently linked to its vasculature and perfusion which can be evaluated by dynamic contrast enhanced (DCE-) MRI using the contrast agent Gd-DTPA. Thus, we hypothesize that DCE-MRI data may provide surrogate information regarding tumor hypoxia. In this study, DCE-MRI data from a rat prostate tumor model were analysed with a Gaussian mixture model (GMM)-based classification to identify perfused, hypoxic and necrotic areas for a total of ten tumor slices from six rats, of which one slice was used as training data for GMM classifications. The results of pattern recognition analyzes were validated by comparison to corresponding Akep maps defining the perfused area (0.84 ± 0.09 overlap), hematoxylin and eosin (H&E)-stained tissue sections defining necrosis (0.64 ± 0.15 overlap) and pimonidazole-stained sections defining hypoxia (0.72 ± 0.17 overlap), respectively. Our preliminary data indicate the feasibility of a GMM-based classification to identify tumor hypoxia, necrosis and perfusion/permeability from non-invasively acquired, in vivo DCE-MRI data alone, possibly obviating the need for invasive procedures, such as biopsies, or exposure to radioactivity, such as positron emission tomography (PET) exams.
Collapse
|
47
|
|
48
|
APPLICATION OF A DUAL-ENERGY MONOCHROMATIC XRAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY. NUCLEAR ENGINEERING AND TECHNOLOGY 2012. [DOI: 10.5516/net.08.2010.044] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
49
|
Magnetic field anisotropy based MR tractography. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2011; 212:386-393. [PMID: 21875818 DOI: 10.1016/j.jmr.2011.07.021] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Revised: 07/19/2011] [Accepted: 07/26/2011] [Indexed: 05/31/2023]
Abstract
Non-invasive measurements of structural orientation provide unique information regarding the connectivity and functionality of fiber materials. In the present study, we use a capillary model to demonstrate that the direction of fiber structure can be obtained from susceptibility-induced magnetic field anisotropy. The interference pattern between internal and external magnetic field gradients carries the signature of the underlying anisotropic structure and can be measured by MRI-based water diffusion measurements. Through both numerical simulation and experiments, we found that this technique can determine the capillary orientation within 3°. Therefore, susceptibility-induced magnetic field anisotropy may be useful for an alternative tractography method when diffusion anisotropy is small at higher magnetic field strength without the need to rotate the subject inside the scanner.
Collapse
|
50
|
TU-C-214-04: Prototype of a Real-Time Adaptive Therapy System Integrating Automatic Soft Tissue Localization with Dynamic Multileaf Collimator (DMLC) Adaptation. Med Phys 2011. [DOI: 10.1118/1.3613136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|