1
|
Effect of MT Technology of Heat Treatment on Reciproc: Comparison of Reciproc, Reciproc Blue, and Reciproc MT. J Endod 2024; 50:520-526. [PMID: 38311116 DOI: 10.1016/j.joen.2024.01.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 01/21/2024] [Accepted: 01/25/2024] [Indexed: 02/06/2024]
Abstract
INTRODUCTION This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.
Collapse
|
2
|
Medication-related osteonecrosis of the jaw triggered by endodontic failure in oncologic patients. Oral Dis 2023; 29:2799-2805. [PMID: 36403223 DOI: 10.1111/odi.14449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 10/25/2022] [Accepted: 11/16/2022] [Indexed: 11/21/2022]
Abstract
OBJECTIVES To describe the association between endodontic treatment failure and medication-related osteonecrosis of the jaw (MRONJ) in a cohort of oncologic patients in therapy with antiresorptive and antiangiogenic drugs. MATERIALS AND METHODS Patients were selected as affected by MRONJ in absence of the common local risk factors (oral surgical procedures or ill-fitting dentures) but showing failure of previous endodontic treatment performed at least 6 months before the starting of antiresorptive/antiangiogenic therapies. Jaw lesions were all surgically treated and patients underwent a strict clinical and radiological follow-up. RESULTS Among 18 patients, who developed 18 MRONJ, the only detectable local risk factor was the presence of teeth with failed endodontic treatment (more precisely, root canal underfilling in eight cases, root canal overfilling in two cases, root perforation in three cases, root fracture in five cases). All patients completely healed after surgical procedure and no recurrence was observed. CONCLUSIONS Endodontic treatment failure should be considered a local risk factor for MRONJ development in oncologic patients. For such reason, it is mandatory to carefully evaluate them prior than the beginning of antiresorptive and antiangiogenic drugs administration.
Collapse
|
3
|
Physicochemical properties and biocompatibility of various bioceramic root canal sealers: in vitro study. J Endod 2023:S0099-2399(23)00283-2. [PMID: 37225037 DOI: 10.1016/j.joen.2023.05.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 05/26/2023]
Abstract
INTRODUCTION The aim of this study was to compare the physicochemical properties and biocompatibility of various calcium silicate-based bioceramic sealers (CSBSs). METHODS Four recently developed CSBSs, including AH Plus Bioceramic Sealer (AHB), EndoSequence BC Sealer (ESB), TotalFill BC Sealer (TTB), and Bio-C Sealer (BIC), were compared with the epoxy resin-based sealer AH Plus (AHP). Their physical properties, including flow, setting time, radiopacity, dimensional stability, and pH, were evaluated according to International Organization for Standardization (ISO) 6876. Their cytotoxicity in human periodontal ligament fibroblast (hPDLF) was assessed through the MTT assay and compared. Additionally, cell attachment to the sealer surface was analysed using green fluorescent protein and confocal laser scanning microscopy (CLSM) to evaluate cell viability. Data were analysed using one-way analysis of variance to determine the difference between groups for categorical variables, followed by Tukey's post-hoc test at the significance level of 95%. RESULTS The flow, setting time, and radiopacity of all tested CSBSs satisfied the ISO 6876/2012 standards. Further, these CSBS showed shrinkage after immersion in distilled water for 30 days and complied with the ISO 6876/2001 requirements. The pH of AHB, ESB, TTB, and BIC was greater than 11 whereas AHP had a pH of 6.69 after 4 weeks. CSBS showed excellent biocompatibility compared with that of AHP (P < .05). CLSM showed that alive hPDLFs were attached well to all the tested CSBS but not to AHP. CONCLUSIONS CSBS have similar physical characteristics within the ISO standards and higher biocompatibility than epoxy resin-based sealers.
Collapse
|
4
|
ESE Position Statement on Root Resorption. Int Endod J 2023. [PMID: 36942472 DOI: 10.1111/iej.13916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 03/15/2023] [Accepted: 03/16/2023] [Indexed: 03/23/2023]
Abstract
This Position Statement on root resorption represents the consensus of an expert committee convened by the European Society of Endodontology (ESE). The statement is based on current clinical and scientific evidence, as well as the expertise of the committee. The aim is to provide clinicians with authoritative information on the aetiology, histopathology, clinical presentation, and recommendations for management of root resorption. It is the intention of the committee to update this position statement at appropriate intervals as further evidence emerges.
Collapse
|
5
|
Erythema Multiforme as Early Manifestation of COVID-19: A Case Report. Pathogens 2022; 11:pathogens11060654. [PMID: 35745508 PMCID: PMC9229542 DOI: 10.3390/pathogens11060654] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/03/2022] [Accepted: 06/05/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is a viral infection involving multi-organ manifestations. The main oral symptoms of COVID-19 associated are taste loss and xerostomia, but literature has reported other oral manifestation, such as oral blisters, ulcers, vesicles and other immunological lesions. This case report showed an Erythema Multiforme (EM) manifesting as oral mucosa lesions in a patient with a late diagnosis of COVID-19 infection. Case Presentation: A 30 years-old Caucasian woman was sent to an oral medicine office, in order to manage painful and oral mucosa lesions associated with target symmetrical skin lesions. Oral examination revealed extensive ulcers in the mouth and crusts on the lips. Based on clinical examinations, a diagnosis of Erythema Multiforme major was made and a drug therapy with steroids was administered. Five days after the specialist visit, the patient discovered that she was positive for COVID-19. The complete recovery occurred in 3 weeks. Conclusion: Confirming the literature studies, EM is an early disease associated with COVID-19 infection.
Collapse
|
6
|
Mechanical properties and metallurgical features of two similar endodontic rotary instruments with different heat treatments (FireWire™ and Gold). Sci Prog 2022; 105:368504221103763. [PMID: 35656775 PMCID: PMC10364944 DOI: 10.1177/00368504221103763] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The aim of this study was to explain the mechanical differences between EdgeTaper Platinum (ETP) and ProTaper Gold (PTG) determining the transition temperatures and the composition of the alloy of ETP, since no data are present in literature. A total of 130 instruments were selected: 65 ETP F2 and 65 PTG F2. 20 instruments per type were submitted to each mechanical tests. The cyclic fatigue and torsional tests were performed at a pre-set temperature of 35 °C ± 1 °C. During the cyclic fatigue test, Time to fracture, number of cycles to fracture (NCF) and the fragment length (FL) were recorded. During the static torsional, Torque to Fracture (TtF) and FL were recorded. The fracture surface of 5 randomly selected fragments from each test was examined through a Scanning Electron Microscopy (SEM) and an EDX analysis was performed. 20 instruments per type were submitted to a bending test The force generated (grams) to bend each was recorded. Recorded data of mechanical and metallurgical tests were statistically analyzed using a one-way analysis of variance (ANOVA) test with significance set to a 95% confidence level. ETP F2 showed a higher cyclic fatigue resistance and bending ability than PTG F2, with a statistically significant difference (p < 0.05). PTG showed a higher torsional resistance with a statistically significant difference (p < 0.05). DSC analysis of 5 samples for each instrument type pointed out that the austenite finish temperature of PTG was higher than the ETP, respectively of 49.99 ± 3.31 (°C) and 38.92 ± 1.75 (°C). EDX analysis confirmed the near-equiatomic composition of the Ni-Ti alloys, with a presence of a third component recognized as rubidium in the ETP samples. ETP showed higher flexibility in comparison with PTG, despite the latter is characterized by a more martensitic characterization. since its Af temperature is higher than the ETP.
Collapse
|
7
|
Present status and future directions ‐ Surgical extrusion, intentional replantation, and tooth autotransplantation. Int Endod J 2022; 55 Suppl 3:827-842. [DOI: 10.1111/iej.13723] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 03/03/2022] [Accepted: 03/04/2022] [Indexed: 11/27/2022]
|
8
|
An Update on Nickel-Titanium Rotary Instruments in Endodontics: Mechanical Characteristics, Testing and Future Perspective-An Overview. Bioengineering (Basel) 2021; 8:bioengineering8120218. [PMID: 34940371 PMCID: PMC8698980 DOI: 10.3390/bioengineering8120218] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 12/10/2021] [Accepted: 12/13/2021] [Indexed: 12/21/2022] Open
Abstract
Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.
Collapse
|
9
|
Abstract
Objective: Aim of the present study is to evaluate mechanical properties of a newly developed rotary file, AF Rotary (Fanta Dental, Shanghai, China), and to compare these features with a worldwide spread rotary file, Protaper Gold F2 (PTG F2; Dentsply Maillefer, Ballaigues, Switzerland). Material and Methods: 60 AF Rotary 25.06 and 60 PTG F2 were divided in three groups of 20 files each. A group underwent to cyclic fatigue resistance tests, second group underwent to torsional resistance tests, third group underwent to bending tests. The statistical analysis was performed using t student test with significance level set at 95% (p < 0.05). Results: AF Rotary showed significantly higher torsional resistance and cyclic fatigue resistance (p < 0.05) when compared to the PTG F2. AF Rotary also showed significantly lower bending resistance (p < 0.05) when compared to the PTG F2. Conclusion: Therefore, within the limitations of this study, the results show better performances for AF Rotary compared to PTG F2 regarding the cyclic fatigue test, the torsional test and the bending test. Since the PTG F2 is a commonly used and widely investigated instrument it could be possible to state that the AF Rotary exhibits remarkable in vitro performances.
Keywords
AF Rotary; Protaper gold; NiTi rotary instruments; Cyclic fatigue; Torsional resistance.
Collapse
|
10
|
Nuclear Magnetic Resonance Microimaging for the Qualitative Assessment of Root Canal Treatment: An Ex Vivo Preliminary Study. Diagnostics (Basel) 2021; 11:1012. [PMID: 34205946 PMCID: PMC8228494 DOI: 10.3390/diagnostics11061012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 05/27/2021] [Accepted: 05/30/2021] [Indexed: 02/07/2023] Open
Abstract
AIM To assess the potential ability of nuclear magnetic resonance micro-imaging (mMRI) to visualize and identify soft tissue debris and unfilled spaces inside radicular canals in endodontic treated extracted teeth, for understanding the causes of treatment failure. Toward this goal, multi-parametric mMRI and cone beam computed tomography (CBCT) were compared. METHODOLOGY A non-recoverable root treated human tooth was extracted due to endodontic failure and excessive mobility. It was examined with both CBCT and mMRI: CBCT was performed with 0.125 mm voxel size (GXCB-500, Kavo-Gendex, Brea, CA, USA) and mMRI was performed with a spectrometer operating at 9.4T magnetic field (Bruker Avance-400, Bruker, Billerica, MA, USA). The mMRI images were obtained with a microimaging probe. Relaxation times (T1 and T2) and diffusion-weighted acquisition sequences were used to obtain multi-parametric maps of the extracted tooth (slice thickness of 200 µm and in plane resolution of 30 × 30 µm2). RESULTS T1 and T2 maps identified unfilled spaces around and close to Gutta-percha cones instead of CBCT images that were not able to highlight this aspect. T1, T2 and apparent diffusion coefficient (ADC) assumed different values in dentine and in voids, characterized by different dimensions. Moreover, they were able to discriminate between infiltrations of water only and deposits of biological material. Because Gutta-percha cones are constituted of hard, non-porous material, they do not provide a signal and in mMRI images appear as zones of noise. CONCLUSIONS Unlike the CBCT exam, mMRI can detect soft tissue debris and unfilled spaces inside radicular canals. Therefore, this in vitro study showed the potential of mMRI to evaluate the quality of the root canal treatment, suggesting its potential benefit in determining the causes of endodontic failure, without the use of ionizing radiation.
Collapse
|
11
|
Persistence of postoperative pain due to extrusion of endodontic obturator plastic carrier: A report of two cases treated with a periradicular microsurgical approach. Dent Res J (Isfahan) 2021; 18:34. [PMID: 34322210 DOI: pmid/34322210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 02/26/2020] [Accepted: 03/05/2020] [Indexed: 12/03/2022] Open
Abstract
The aim of the present study was to describe two clinical cases showing postoperative pain associated with the use of plastic carrier obturation system and apical bone fenestration. The patients were treated by surgical access and apicoectomy through a modern technique (using magnification and microsurgical approach), thus removing the direct contact between obturation material and submucosal connective tissue. The surgical interventions were carried on without the occurrence of any complication. Postsurgical adverse sequelae were negligible. After few weeks from the surgery, all symptoms disappeared. Radiographic healing was observed after 48 months. The presence of apical bone fenestration could be the cause of persistent pain after root canal treatment. The contact between plastic carrier and submucosal connective tissue could be the direct cause of spontaneous pain even in absence of periapical infection. Since the clinical diagnosis could be difficult, the use of tridimensional radiology could be justified. Surgical approach, by the removal of the contact between the carrier and connective tissues, can be considered a viable option to treat these particular affections.
Collapse
|
12
|
A Paradigm Shift for Torsional Stiffness of Nickel-Titanium Rotary Instruments: A Finite Element Analysis. J Endod 2021; 47:1149-1156. [PMID: 33915175 DOI: 10.1016/j.joen.2021.04.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 03/16/2021] [Accepted: 04/14/2021] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The aim of this study was to investigate the influence of mass and the polar moment of inertia on the torsional behavior of nickel-titanium rotary instruments to understand which parameter of cross-sectional design had a key role in terms of torsional resistance. METHODS Four different instrument models were designed and meshed using computer-aided engineering software (SolidWorks; Dassault Systems, Waltham, MA). Instrument models shared the same characteristics, except for cross-sectional design; triangle, rectangle, square, and hollow square geometry was selected. Finite element analysis was performed simulating a static torsional test using the FEEPlus internal solver (Solid Works). Von Mises stress and torsional load at fracture were calculated by the software. Linear regression analysis was performed to investigate the relationship of the polar moment of inertia, cross-sectional area, inner core radius, and mass per volume on the torsional resistance of nickel-titanium rotary instruments. RESULTS The polar moment of inertia positively affected the maximum torsional load with the highest level of correlation (R2 = 0.917). It could be stated that the higher the polar moment of inertia is, the more maximum torsional load at fracture is present. Mass and cross-sectional area had a lower level of correlation compared with the polar moment of inertia (R2 = 0.5533). According to this, 2 instruments with the same mass/mm and/or cross-sectional area could have different torsional resistance. CONCLUSIONS The polar moment of inertia can be considered as the most important cross-sectional factor in determining the torsional resistance of rotary instruments over metal mass and cross-sectional area.
Collapse
|
13
|
Incidence of Different Types of Intracanal Fracture of Nickel-Titanium Rotary Instruments: A Systematic Review. J Contemp Dent Pract 2021; 22:427-434. [PMID: 34267014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
AIM The aim of this systemic review is to investigate these parameters by analyzing the characteristics of fractured instruments to determine which is the most relevant mechanical stress that induces intracanal separation in vivo. BACKGROUND The fracture of nickel-titanium (Ni-Ti) instruments is a result of flexural fatigue and torsional fatigue. An electronic search was conducted in MEDLINE database, Web of Science, and Cochrane following preferred reporting items for systematic reviews and meta-analyses guidelines. Data were collected and the key features from the included studies were extracted. Overview quality assessment questionnaire scoring assessed the quality of the articles. A total of 12 articles were selected, where the lowest score was 13. REVIEW RESULTS Considering Ni-Ti rotary instruments, this overall evaluation comprehends 939 broken instruments with an incidence of fracture of 5%. Out of the 12 selected articles, 10 studies revealed that flexural failure was the predominant mode (range of 62-92%). It appears that motion plays an important role when it comes to mechanisms of fracture. The majority of defects found in hand-operated instruments were in the form of torsional failure. Although the major cause of separation of rotary instruments is flexural fatigue, smaller instruments show more torsional fracture than the larger instruments. The average fragment length was found to be 2.5 mm and 3.35 mm, respectively, for torsional failure and flexural failure. The risk of bias depends on fractographic analysis. CONCLUSION Flexural fatigue is the predominant mode of fracture in rotary Ni-Ti instruments. The type of motion and size of the instrument seem to affect the mechanism of fracture. Fragment length may show a strong association with the type of fracture mechanism. CLINICAL SIGNIFICANCE This systemic review found that flexural fatigue is the most relevant mechanical stress that induces intracanal separation in vivo. Moreover, in clinical practice, the fragment length might be an excellent indicator of the type of fracture.
Collapse
|
14
|
Nickel-Titanium Rotary Instruments: An In Vitro Comparison (Torsional Resistance of Two Heat-treated Reciprocating Files). J Contemp Dent Pract 2021; 22:361-364. [PMID: 34267004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
AIM AND OBJECTIVE The present study aims to evaluate the difference in torsional resistance of two reciprocating nickel-titanium (Ni-Ti) rotary files: WaveOne Gold and EdgeOne Fire. MATERIALS AND METHODS A total of 40 nickel-titanium rotary instruments (n = 40): 20 WaveOne Gold Small (WOGS) and 20 EdgeOne Fire Small (EOFS) were divided into two groups. Each instrument was tested using a torsional resistance device already validated in previous studies to evaluate and compare torsional resistance. The static torsional test was implemented by blocking each instrument at 3 mm from the tip and rotating it until fracture with a reciprocating motion. Torque to fracture (TtF) and fragment length (FL) were measured and statistically analyzed. RESULTS Statistical analysis of TtF found significant differences between the two groups (p<0.05). The EOFS showed higher TtF if compared to WOGS, with a mean value and a standard deviation of 3.05 ± 0.07 (N cm) against 2.97 ± 0.08 (N cm). Data for FL showed no significant differences (p>0.05) between the two groups. CONCLUSION According to the results of this study, it is reasonable to assert that EOFS instruments showed a higher torsional resistance if compared to the WOGS. CLINICAL SIGNIFICANCE As evidenced by this study, EOFS should be considered as a safer solution, in terms of torsional resistance, if compared to WOGS, reducing the risk of intracanal separation due to excessive torsional load.
Collapse
|
15
|
Operative Torque Analysis to Evaluate Cutting Efficiency of Two Nickel-Titanium Rotary Instruments for Glide Path: An In Vitro Comparison. J Contemp Dent Pract 2021; 22:215-218. [PMID: 34210917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
AIM AND OBJECTIVE The aim and objective of this study was to evaluate and compare the cutting efficacy of two different nickel titanium rotary instruments by a novel methodology: the operative torque (torque and time needed to progress toward the apex). MATERIALS AND METHODS Ten fresh extracted upper first premolars with two canals were instrumented with a KaVo (Biberach, Germany) and a KaVo 1:1 handpiece at 300 rpm with maximum torque set at 2 N. One canal was instrumented with ProGlider NiTi rotary instruments (Dentsply Sirona Endodontics, Ballaigues, Switzerland), with tip size of 16.02, and the other one with EgdeGlidePath rotary instrument (EdgeEndo, Albuquerque, New Mexico). Mean instrumentation time, mean torque values, and maximum torque values were evaluated for each instrument. The significance level was set at p <0.05. RESULTS EdgeGlidePath instruments reached the working length in significantly less time with a significantly smaller amount of torque when compared to ProGlider (p >0.05). No instruments exhibited flute deformation or underwent intracanal failure. CONCLUSIONS Operative torque is related to the capability to cut dentin and progress toward the apex: the smaller the torque values, the higher the cutting ability (and safety). Operative torque is also dependent on debris removal and irrigation techniques. Nevertheless, both operative torque and instrumentation time are clinically relevant parameters for evaluating instruments' performance (i.e., cutting ability). CLINICAL SIGNIFICANCE Operative torque during endodontic instrumentation helps understanding the overall performance in terms of both cutting efficiency and safety.
Collapse
|
16
|
European Society of Endodontology position statement: Surgical extrusion, intentional replantation and tooth autotransplantation: European Society of Endodontology developed by. Int Endod J 2021; 54:655-659. [PMID: 33501680 DOI: 10.1111/iej.13456] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 11/30/2020] [Indexed: 12/25/2022]
Abstract
This European Society of Endodontology (ESE) position statement on surgical extrusion, intentional replantation and tooth autotransplantation represents the consensus of an expert committee, convened by the ESE. A narrative review in the International Endodontic Journal (Plotino et al. 2020, international Endodontic Journal, 53, 1636-52) formed the basis for the position statement. The review provided detailed information on the background, clinical procedures and the outcome of surgical extrusion, intentional replantation and tooth autotransplantation techniques. The aim of the current statement is to summarize the best available evidence on these clinical techniques to provide appropriate clinical guidance to undergraduate and postgraduate students, dental practitioners, clinical teachers and researchers. The current position statement will be updated by the ESE periodically to reflect new evidence as it becomes available to provide the most current treatment guidance for clinical practice.
Collapse
|
17
|
Influence of Clinical Operative Technique on Debris Extrusion of Two Reciprocating Files. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLÍNICA INTEGRADA 2021. [DOI: 10.1590/pboci.2021.114] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
18
|
Influence of shaft length on torsional behavior of endodontic nickel-titanium instruments. Odontology 2020; 109:568-573. [PMID: 33245455 PMCID: PMC8178130 DOI: 10.1007/s10266-020-00572-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 11/09/2020] [Indexed: 11/23/2022]
Abstract
Torsional stresses are one of the most frequent causes of intracanal separation of nickel–titanium endodontic instruments, which represents a great concern of endodontists. For this reason, torsional resistance of rotary instruments has been deeply investigated by determining all parameters that can influenced it, that can be summarized in: (1) Tooth-related factors, (2) Strategy-related factors and (3) Instrument-related factors. This study was conducted to examine the influence of shaft length on torsional resistance of a nickel–titanium rotary instrument and if it should be considered as an Instrument-related factor. With this aim, 120 Twisted Files Adaptive M-L (TFA M-L) NiTi instruments (SybronEndo, Orange, CA, USA) were divided into 6 experimental groups (n = 20), according to instruments length and size: Group 1, 20 TFA M-L1 25/08 23 mm; Group 2, 20 TFA M-L1 25/08 27 mm; Group 3, 20 TFA M-L2 35/06 23 mm; Group 4, 20 TFA M-L2 35/06 27 mm; Group 5, 20 TFA M-L3 50/04 23 mm; and Group 6, 20 TFA M-L3 50/04 27 mm. All instruments were submitted to a static torsional test, blocking each instrument at 3 mm from the tip and rotating it until its fracture. Torque to Fracture (TtF) and fragments length were registered and all data were statistically analyzed. Results showed that Groups 2, 4 and 6 had a higher TtF, respectively, than Groups 1, 3 and 5, which differ from the former just for shaft length. Group 6 showed the highest torsional resistance (1.31 ± 0.08 Ncm), whilst Group 1 the lowest (0.40 ± 0.08 Ncm). According to that, it can be stated that the longer the instrument, the higher the torsional resistance is, proving that shaft length should be considered as an important factor about torsional resistance.
Collapse
|
19
|
Correlation between endodontic pulpal/periapical disease and retrograde peri-implantitis: A case series. AUST ENDOD J 2020; 47:358-364. [PMID: 33159493 DOI: 10.1111/aej.12458] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2020] [Revised: 09/26/2020] [Accepted: 10/21/2020] [Indexed: 12/30/2022]
Abstract
Retrograde peri-implantitis is a symptomatic complication, characterised by radiographic detection of bone loss at the periapex of the implant. The aim of this study was to investigate the possible endodontic aetiology, evaluating the effectiveness of surgical treatment without endodontic therapy of adjacent teeth. In the 10-year interval, three patients reported symptoms of retrograde peri-implantitis after a mean period of 30.6 days from implant placement. Mean follow-up after surgical procedures was 8.66 years, with an implant survival of 100%. Retrograde peri-implantitis was probably caused by colonisation of the apical surface of the implant by bacteria persisting in the area after endodontic failure/apical periodontitis, reactivated by drilling in the site. In all cases, the adjacent teeth remained vital during the years, showing that a direct cause-and-effect relationship between pulpal/periapical disease of adjacent teeth and retrograde peri-implantitis was never present.
Collapse
|
20
|
Management of a Complex Case during COVID-19 Time Using One-day Digital Dentistry: A Case Report. J Contemp Dent Pract 2020; 21:1284-1292. [PMID: 33850077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
AIM AND OBJECTIVE The aim of the present case report is to describe the digital management of an implant prosthetic rehabilitation performed by the use of different digital technologies, which allowed to successfully perform in 1 day both the surgical and the prosthetical stages with a minimally invasive approach and a high standard of care. BACKGROUND Coronavirus disease-2019 (COVID-19) pandemic is affecting dental everyday practice. Clinicians have to reduce the number of patients per day and the time they spend in the dental office. Minimally invasive and digital approaches, with less possible exposure and interaction, are suggested to reduce the risk of infection. CASE DESCRIPTION The failure of a short-span implant prosthetic rehabilitation combined with pain and mobility of the involved teeth was the main complaint reported by a 78-year-old male patient, who asked an urgent appointment to solve the problem. An intraoral scanner allowed the clinician to immediately take a preliminary digital impression of the arch to be treated. The resulting 3D files were sent by e-mail to the dental technician who provided a digital wax-up for the computerized workflow. Computer-aided implantology (CAI) performed using an in-office cone-beam computed tomography (CBCT) allowed clinician to guide the surgical approach in a prosthetic manner. Such an integration inside a well-defined workflow was the key for a successful and rapid treatment. CONCLUSION By using new innovative digital technology, the treatment was completed in 1 day, reducing the risk of COVID-19 by limiting the number of appointments and reducing contacts in confined environments like the dental office and public transportations. It also helped to reduce materials production and people movement in the treatment of dental emergency. CLINICAL SIGNIFICANCE The possibility of performing an effective treatment saving time by using efficient technology and a minimally invasive procedure highlights the importance of digital planning in order to optimize every single step of the treatment. Digital workflow reduces also the movement of potentially infected materials from the office to the dental laboratory.
Collapse
|
21
|
Nonsurgical Retreatment Using Regenerative Endodontic Protocols: A Case Report. J Contemp Dent Pract 2020; 21:1275-1278. [PMID: 33850075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
AIM AND OBJECTIVE The aim of this case report was to describe regenerative endodontic procedures (REPs) of the previously treated mature teeth with long-term results. BACKGROUND Regenerative endodontic procedures are aimed to treat apical periodontitis and regenerate the pulp-dentin complex in necrotic teeth. However, there is no consensus in using REPs in the previously treated mature teeth. The aim of this case report was to describe REPs of the previously treated mature teeth with long-term results. CASE DESCRIPTION A 25-year-old woman presented pain on chewing on 15 and swelling (WHO numbering system). The tooth had been endodontically treated and restored 4 years ago. After removing the old root canal filing, the roots were irrigated with 2.5% sodium hypochlorite and 17% EDTA using sonic activation. Calcium hydroxide (CH) was used as medicament for 3 weeks. At the second visit, CH was removed, and canals were irrigated as like as the first visit. Apical bleeding was induced, and concentrated growth factors (CGFs) were placed inside the root canal. The tooth has been followed up to 3 years. CONCLUSION The tooth was functional and asymptomatic at the recall visits. Since the first-year follow-up, the tooth responded to the electric pulp test and the thermal test. Radiological examinations revealed healing of apical lesion and hard tissue deposition. CLINICAL SIGNIFICANCE Regenerative endodontic procedures can offer an advantage over traditional endodontic procedures in terms of tertiary healing, with a predictable, user-friendly procedure also for retreatment cases.
Collapse
|
22
|
Differences in endodontic emergency management by endodontists and general dental practitioners in COVID-19 times. Braz Oral Res 2020; 34:e122. [PMID: 33146318 DOI: 10.1590/1807-3107bor-2020.vol34.0122] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 08/18/2020] [Indexed: 12/14/2022] Open
Abstract
The aim of this study was to assess the differences, if any, between general dental practitioners (GDPs) and endodontists, in the diagnosis and treatment of endodontic emergencies during the worldwide outbreak of COVID-19. An online questionnaire was randomly sent by social media to clinicians in different countries from 24 April, 2020 to May 4, 2020. The survey consisted of a series of questions about demographic characteristics, endodontic emergency diagnoses, approaches to prevent aerosol formation, drug prescriptions in case of symptomatic irreversible pulpitis, and the ways in which dentists managed endodontic emergencies during the COVID-19 lockdown. A total of 1,058 dentists responded to the questionnaire; 344 (32.6%) of the participants were endodontists. Slightly less than half of the participants (n = 485, 45.8%) worked during the lockdown, but only 303 participants (28.6%) treated endodontic cases/emergencies. The responses showed agreement between endodontists and GDPs regarding the diagnosis of symptomatic irreversible pulpitis (SIP), symptomatic apical periodontitis (SAP), reversible pulpitis, and asymptomatic irreversible pulpitis (AIP). SIP and SAP were considered an emergency, whereas reversible pulpitis and AIP were not considered an emergency (p > 0.05). Non-aerosol-generating procedures and treatment approaches differed between the groups (p < 0.05). One-third of the participants did not use rubber dam (p > 0.05). Ibuprofen and amoxicillin-clavulanic acid were the most frequently prescribed drugs for pain associated with SIP. In conclusion, the most relevant findings in our survey were the differences between endodontists and GDPs in diagnosis, precheck triage, deep caries excavation procedures, and endodontic emergency pain relief strategies.
Collapse
|
23
|
Effect of Flexural Stress on Torsional Resistance of NiTi Instruments. J Endod 2020; 47:472-476. [PMID: 33096192 DOI: 10.1016/j.joen.2020.10.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 09/27/2020] [Accepted: 10/15/2020] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Previously published studies have deeply investigated the characteristics of flexural and torsional resistance of nickel-titanium rotary instruments, but none of them investigated the relationship between the 2 stresses. The objective of the present study was to evaluate the influence of flexural stresses over torsional resistance. METHODS Sixty S-One 20.04 files (Fanta Dental, Shanghai, China) were used in the present study (N = 60) and divided into 3 test groups of 20 files. A customized device made of a mobile structure with a connection that holds the handpiece and the artificial canal was used for the experiment to make the measurements repeatable. The artificial canals were created with a 90° curvature, a 60° curvature, and lastly a straight canal. Each file was rotated at 300 rpm with a maximum torque value of 5.5 Ncm with the apical 2 mm firmly secured in a vise. The torque at fracture and the time to fracture were recorded by the software integrated in the handpiece and evaluated through statistical analysis. RESULTS Statistical analysis found significant differences in the values of torque to fracture (TtF) between these 3 groups (P < .05). The 90° curved canal group showed the highest TtF value, and the 60° curved canal group showed a higher TtF value than the straight canal group. CONCLUSIONS The results of the present study demonstrated a positive influence of flexural stresses over torque at fracture of rotary files. When nickel-titanium instruments were used in a 90° or 60° curvature, the values of torque at fracture increased compared with the same instruments that rotated in the straight canal.
Collapse
|
24
|
Standardization of Endodontic Access Cavities Based on 3-dimensional Quantitative Analysis of Dentin and Enamel Removed. J Endod 2020; 46:1495-1500. [DOI: 10.1016/j.joen.2020.07.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 07/12/2020] [Accepted: 07/13/2020] [Indexed: 10/23/2022]
|
25
|
Clinical procedures and outcome of surgical extrusion, intentional replantation and tooth autotransplantation – a narrative review. Int Endod J 2020; 53:1636-1652. [DOI: 10.1111/iej.13396] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 08/23/2020] [Accepted: 08/24/2020] [Indexed: 12/19/2022]
|
26
|
Precision of Dynamic Navigation to Perform Endodontic Ultraconservative Access Cavities: A Preliminary In Vitro Analysis. J Endod 2020; 46:1286-1290. [DOI: 10.1016/j.joen.2020.05.022] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 05/09/2020] [Accepted: 05/31/2020] [Indexed: 12/13/2022]
|
27
|
Abstract
AIM The present study was conducted to assess the perceived risk of COVID-19 transmission in dental professionals (DPs), that include dentists and dental auxiliary staffs, and whether rapid tests should be a recommended tool to constrain the transmission of the COVID-19, and who should be bearing their cost (governments, dentists, or patients) through an online survey. MATERIALS AND METHODS A sample size of n = 700 was recruited in the study. The study included DPs from all over the world. A randomized selection of samples was done through dental groups present on social networks. An online survey was conducted in April 2020, using the Google Form software to provide questions and collect and elaborate answers. Data were analyzed using the statistical software STATA and presented in terms of percentages. RESULTS About 78% of the study participants perceived a very high risk of COVID-19 contamination in dental settings. Nearly 80% of the study participants were willing to be subjected to rapid tests and the same could be performed on patients visiting their dental clinics, which could prevent the spread of the disease. About 55% of the participants had reported that additional costs for the rapid tests should be borne by the governments. CONCLUSION The results of the present survey report that DPs do not feel safe and perceive a high risk of COVID-19 contagion and prevention of the disease could be done by performing rapid tests on dentists, dental staff, and patients visiting the dental clinics irrespective of age and gender of the participants. SIGNIFICANCE Since all the dentists and allied staff have perceived increased risk for COVID-19 transmission, it is important that preventive measures are implemented through rapid test kits at the earliest.
Collapse
|
28
|
Fatigue Resistance of Two Nickel-Titanium Rotary Instruments before and after Ex Vivo Root Canal Treatment. J Contemp Dent Pract 2020; 21:728-732. [PMID: 33020354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
AIM The aim of the present study is twofold: to evaluate cyclic fatigue resistance differences of two different nickel-titanium rotary instruments, brand new and after an ex vivo instrumentation of single root extracted teeth. MATERIALS AND METHODS Twenty new S One 20.06 were randomly divided into two groups. The first group (n = 10) was immediately subjected to a cyclic fatigue test (S One Group I). The second group (n = 10) (S one Group II) performed a cyclic fatigue test after three ex vivo root canal treatment with a single-file technique. The same process has been carried out for 20 M-Two 20.06 instruments. RESULTS Mean time to fracture (TtF) for Group I was 51.14 ± 1.28 for S One and 32.62 ± 0.17 for M-Two 20.06 and for Group II was 46.00 ± 0.99 for S One and 27.75 ± 1.58 for M-Two 20.06. The reduction in TtF values from Group I to Group II was 11% for S One and 15% for M-Two. Statistical analysis found significant differences in all the groups examined (p value < 0.05). Mean fragment length (FL) for Group I was 3.07 ± 0.17 for S One and 3.05 ± 0.14 for M-Two 20.06 and for Group II was 3.05 ± 0.07 for S One and 3.05 ± 0.14 for M-Two 20.06. Statistical analysis was pursued, and no significant difference was found (p value > 0.05). CONCLUSION The S-One showed significantly more resistance to cyclic fatigue stress than M-Two for both new and used instruments. This validates the hypothesis that the AF H wire enables the S One files to endure more the cyclic fatigue stresses. CLINICAL SIGNIFICANCE This study demonstrates the cyclic fatigue resistance of a new endodontic instrument after repetitive usage.
Collapse
|
29
|
Accuracy Evaluation of 14 Maxillary Full Arch Implant Treatments Performed with Da Vinci Bridge: A Case Series. MATERIALS 2020; 13:ma13122806. [PMID: 32580340 PMCID: PMC7344455 DOI: 10.3390/ma13122806] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 06/07/2020] [Accepted: 06/18/2020] [Indexed: 11/29/2022]
Abstract
The use of pterygoid implants can be an attractive alternative to sinus bone grafting in the treatment of posterior atrophic maxilla. This technique has not been widely used because of the difficulty of the surgical access, the presence of vital structures, and the prosthetic challenges. The use of dynamic computer aided implantology (DCAI) allows the clinician to utilize navigation dental implant surgery, which allows the surgeon to follow the osteotomy site and implant positioning in real time. A total of 14 patients (28 pterygoid implants and 56 intersinusal implants) were enrolled in the study for a full arch implant prosthetic rehabilitation (4 frontal implants and 2 pterygoids implants), using a dynamic navigation system. The reported accuracy of pterygoid implants inserted using DCAI was 0.72 mm at coronal point, 1.25 mm at apical 3D, 0.66 mm at apical depth, and 2.86° as angular deviation. The use of pterygoid implants in lieu of bone grafting represents a valid treatment opportunity to carry out a safe, accurate, and minimally invasive surgery, while reducing treatment time and avoiding cantilevers for a full implant prosthetic rehabilitation of the upper arch.
Collapse
|
30
|
Fine Aerosols and Perceived Risk of COVID-19 among Italian Dental Practitioners: An Experimental Survey. J Contemp Dent Pract 2020; 21:599-603. [PMID: 33025925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
AIM The aim of the present study was to take a survey on Italian practitioners concerning the perceived risks of aerosol contamination in COVID-19 times and their attitude toward modifications of treatment protocols to reduce this risk. MATERIALS AND METHODS Power analysis calculated a minimum sample size of 150 participants at 99% confidence level with a 5% margin of error. To homogenize responses elicited by different preventive measures by various national governments, only Italian dentists were included in the survey: overall 500 responses were collected. RESULTS Of the 500 analyzed respondents, there were 266 females and 234 males; 379 practitioners were allocated in the more experienced groups, and the remaining 121 in the less experienced group based on less or more than 5 years of practice. The 70% of the dentists consider the dental practice more dangerous for the diffusion of COVID-19 than other social activities. The 5% consider dental practice more dangerous only for the patients. Aerosol contamination was perceived as a risk from the most dentist (70%), but there was agreement on the most dangerous way of cross infection in dental settings. Most of the dentists (55%) believed implementations in their protocols were needed to reduce the risk of COVID-19 infections. No significant differences were found within the groups: both women and men, as well as practitioners with different experience levels (younger or older than 35 years) perceived very similarly the problems related to COVID-19 in dentistry (p > 0.05). CONCLUSION The survey demonstrated that COVID-19 had a great impact on dental practitioners; it increased not only fear of aerosol contamination during dental treatments but also influenced the fear of close contacts. SIGNIFICANCE Airborne and waterborne infections are related with dental treatments and considered the preferred ways of diffusion for COVID-19. The risk of aerosol-related infections could interfere with the clinical practice of the dentist, during the COVID-19 pandemic; the limitations that provided changes to everyday behavior could affect the perception of the safety of the operators, staff, and patient and this could also affect economically the dental office.
Collapse
|
31
|
Academic Dental Activities and COVID-19 Pandemic. J Contemp Dent Pract 2020; 21:598. [PMID: 33025924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
COVID-19 pandemic has strongly and rapidly affected routine lifestyle and consequently, dental business, practice, and education. During the pandemic period, most Governments worldwide made specific regulations or recommendations to close practices, to avoid non-urgent dental therapies and treat only dental emergencies. Some recent surveys1,2 showed how dentists perceived the COVID-19 risk and how they reacted: by modifying their way of working, by reducing aerosol producing procedures, by improving staff and patient's safety with the increased use of personal protective equipment, environmental disinfection and limited access to dental offices, increasing use of remote consulting and triage.
Collapse
|
32
|
Centering Ability of a New Nickel-Titanium Rotary Instruments with a Peculiar Flat-side Design: An In Vitro Study. J Contemp Dent Pract 2020; 21:539-542. [PMID: 32690836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
AIM The aim of the present study was to investigate the role of the flat design compared with a non-flat designed instrument on the centering ability in a simulated root canal system. MATERIALS AND METHODS Two file systems were chosen: the F-One (Fanta Dental, Shanghai, China) and a prototype with the same design but without the flat-side design. A total of 50 simulated L-shaped root canals in resin blocks were shaped with a new instrument each. Pre- and postcanal preparation images were captured and superimposed to measure and compare the canal transportation and evaluate the centering ability of each file. The t test was performed and the level of significance was set at p < 0.05. RESULTS Prototype files removed significantly less resin from the inner and the outer parts of the canal and showed significantly higher mean transportation values. CONCLUSION It can be concluded that the F-One file system demonstrated better shaping ability compared with the prototype file system in L-shaped resin-simulated canals. CLINICAL RELEVANCE The present study showed the safety of the flat-side design, minimizing the risk of iatrogenic errors such as ledging, perforation, or zipping of the root canal.
Collapse
|
33
|
Abstract
A technology called Trace Registration (TR) has been introduced to allow dynamic navigation of implant placement without the need for a thermoplastic stent. This study was undertaken in order to validate the accuracy of the TR protocol for dynamically guided implant surgery. A retrospective, observational, in vivo study was performed using dynamic navigation via the TR protocol. The preoperative cone beam computed tomography (CBCT) plan was superimposed and registered (aligned) with the postoperative CBCT scan to assess accuracy parameters. A total of 136 implants were placed in 59 partially edentulous arches. Mean deviation between the planned and actual position for all implants was 0.67 mm at the coronal level (entry point), 0.9 mm at the apical level, and 0.55 mm in depth, with an angle discrepancy of 2.50 degrees. Tracing 5 to 6 teeth tended to improve accuracy results compared to tracing 3 to 4 teeth. TR is as accurate as traditional registration and statically guided methods for implant surgery.
Collapse
|
34
|
How to Improve Properties of Nickel-Titanium Rotary Instruments. J Contemp Dent Pract 2020; 21:351-352. [PMID: 32584267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In the last decades, the use of nickel-titanium (Ni-Ti) rotary instruments has become the most effective and popular method among endodontists for shaping root canals, even if there are still concerns regarding the increased risks of intracanal breakage or weakening of the instruments.1,2 So manufacturers started to modify the cross-sectional geometrical aspects of the files in order to improve their resistance to torsional and cyclic fatigue. Design is a major feature in determining instruments' properties including cutting efficiency, removal of debris, stresses generated during instrumentation, and the relative resistance to these stresses; however, a perfect design is not existing and any change in design is likely to provide some advantages but also some disadvantages.3,4.
Collapse
|
35
|
C-shaped canal configuration in mandibular premolars and molars: Prevalence, correlation, and differences: An In Vivo study using cone-beam computed tomography. Niger J Clin Pract 2020; 23:232-239. [PMID: 32031099 DOI: 10.4103/njcp.njcp_335_19] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AIMS To evaluate the prevalence, correlation, and differences of C-shaped canal morphology in mandibular premolars and molars by means of cone-beam computed tomography (CBCT). MATERIALS AND METHODS A total of 1433 mandibular premolars and molars CBCT scans from the Saudi population were evaluated. Axial sections of the roots were acquired at coronal, middle, and apical levels to evaluate C-shaped canals types. The prevalence, correlation, differences of C-shaped canals, bilateral/unilateral presence, gender differences, and location of external grooves on roots were assessed. RESULTS The prevalence of C-shaped canals in the first premolars was 1.5%, 0.80% in second premolars and 7.9% in second molars, whereas C-shaped canals were absent in first molars. No correlation was found between the presence of C-shaped canals within premolars and molars and between the two groups in the same individual. Both premolars and molars exhibited different types of C-shaped canals, C2 being predominant in premolars and C3 in second molars. Longitudinal external grooves were mostly located on mesiolingual (ML) surface in premolars and lingual in molars. Females showed more prevalence of C-shaped canals in second molars and no differences in premolars. Bilateral symmetry and unilateral presence in premolars and second molars were not significant. CONCLUSIONS Although the prevalence of C-shaped canals is significantly higher in mandibular second molars, they are also found in mandibular premolars but in small percentages. No significant differences were found between both genders and both sides. Since they exhibit unpredictable morphology and differences across the root length, the use of small field CBCT is recommended when such anatomy is presented in a tooth indicated for root canal treatment for better management.
Collapse
|
36
|
Potential of Operative Torque in Evaluating NiTi Instruments. J Contemp Dent Pract 2020; 21:113. [PMID: 32381811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The role of nickel-titanium (NiTi) in the production of endodontic instruments increased in the last few decades; therefore, the way of evaluation of its performance increased as well. Nowadays, there are several ways to evaluate NiTi instruments, divided into static and dynamic tests. The static ones are cyclic fatigue tests, torsional resistance tests, flexibility, and cutting efficiency tests. These methodologies have been deeply used to evaluate some of the metallurgical properties of the instruments on the market. Up-to-date, we know very well the behavior of NiTi under static conditions, but these knowledges are too fragmented to be relevant for understanding and evaluating the complexities of intracanal instrumentation. Starting from the purpose to introduce the variable of movement in the testing procedure, some dynamic tests have been proposed, such as dynamic cyclic fatigue test.1,2 Although these kinds of studies were capable of evaluating more precisely the behavior of rotary instruments inside the root canal, they could not take into account, at this moment, the complexities of stresses that instruments undergo during the shaping procedure.3-5 Therefore, some of these tests are not accepted anymore by the scientific community and on the contrary they do not help the general practitioner to orientate in the large amount of rotary instruments present on the market.6 This tends to withdraw the general dentistry from the scientific literature, wearing a groove between the practice and the science.7 Starting from these ideas, in the last couple of years some authors started to think the proper way to real-time evaluation of the performance of NiTi rotary instruments inside the root canal. To do so, a countable and repeatable measurement of instrument's developed stresses was needed. Setzer and Böhme8 first used the torque generated by Revo-S, Vortex, and ProFile to evaluate their performance during instrumentation. The so-called "operative torque" is the summation of torque generated in each point of the instrument during its simultaneous movement around its own axis and up and down inside the canal. The recorded values are influenced by both torsional and flexural stresses, becoming this way a reliable method to analyze, evaluate, and compare the performance of NiTi instruments inside the root canal.9 This methodology is applicable for not only in vitro but also in vivo measurement, as demonstrated by Gambarini et al.10 The main drawback of this kind of evaluation is the not well-determined correlation between the torsional and the flexural stresses; therefore, it is still unpredictable how each influence the other. In conclusion, the potential of real-time torque measurement is wide and still unexplored, but further studies are needed to better understand how torque is developed inside the root canal.
Collapse
|
37
|
Torsional Resistance of Two New Heat Treated Nickel Titanium Rotary Instruments: An in Vitro Evaluation. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLÍNICA INTEGRADA 2020. [DOI: 10.1590/pboci.2020.156] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
38
|
Anatomic Two-dimensional and Three-dimensional Models for Cyclic Fatigue Testing of Endodontic Instruments. IRANIAN ENDODONTIC JOURNAL 2020; 15:100-105. [PMID: 36704437 PMCID: PMC9709840 DOI: 10.22037/iej.v15i2.27342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 02/03/2020] [Accepted: 02/19/2020] [Indexed: 01/28/2023]
Abstract
Introduction In this study, new devices were developed and evaluated for cyclic fatigue testing (CTF) of endodontic instruments in two-dimensional (2D) and three-dimensional (3D) replicas of the internal anatomy of a mesial root of a mandibular molar. Methods and Materials The trajectories of both curved mesial canals of the same root were outlined from computed tomographic scans and exported to a computer assisted drawing (CAD) software. In the CAD program, the canals were virtually enlarged to a size 25/0.06. The CTF devices were then prototyped in stainless steel. The 2D models represented the bucco-lingual (BL) and mesio-distal (MD) views of the canals, while the original trajectory was kept in the 3D model. Vortex Blue 25/0.06 instruments were tested for fatigue in the six canals (n=12). The number of cycles to failure (NCF) and fragment length (mm) were recorded. Data was statistically analyzed (ANOVA and post-hoc Games-Howell test) with the level of significance set at 5%. Results The mean NCF was significantly different among all the canals (P<0.05). The lifespan of the files was greater in the 2D-BL models, followed by the 2D-MD and 3D. The mean fragment length was also different among the tested models (P<0.05). Conclusions The tested 2D and 3D representations of the same canal trajectory resulted in significant differences both in the amount of stress (seen from NCF) and localization of the maximum stress (seen from fragment length). Further investigations are required to better understand the effects of different 3D curvatures on the cyclic fatigue of endodontic instruments.
Collapse
|
39
|
Future Trends in Endodontics: From the Virtual Assessment of the Anatomy to the Computer-driven Approach. J Contemp Dent Pract 2020; 21:1. [PMID: 32381792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Root canal treatment is one of the most challenging practices in dentistry as the complexity and the variability of the endodontic space can often lead the operator to create false trajectories or missing canals. The technical advances in the development of even more efficient and resistant endodontic instrument reached important results in the last few years with the adoption of NiTi alloys and thermal treatments, which could increase the flexibility and the resistance of the instruments.1,2.
Collapse
|
40
|
Analysis of Stability in Time of Marginal Adaptation of Endosequence Root Repair Material on Biological Samples. DENTAL HYPOTHESES 2020. [DOI: 10.4103/denthyp.denthyp_98_19] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
41
|
Procedure endodontiche rigenerative: stato dell’arte e procedure cliniche. DENTAL CADMOS 2020. [DOI: 10.19256/d.cadmos.01.2020.05] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
42
|
In Vivo Evaluation of Operative Torque Generated by Two Nickel-Titanium Rotary Instruments during Root Canal Preparation. Eur J Dent 2019; 13:556-562. [PMID: 31891973 PMCID: PMC6938430 DOI: 10.1055/s-0039-1698369] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Objectives
This
in vivo
study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars.
Materials and Methods
Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (
n
= 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds).
Statistical Analysis
Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann–Whiney
U
test with a significance level set at 5%.
Results
No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (
p
> 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2–9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35–21.1) (
p
< 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18–0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05–0.17) (
p
< 0.05).
Conclusions
Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals.
Collapse
|
43
|
Endodontic Microsurgery Using Dynamic Navigation System: A Case Report. J Endod 2019; 45:1397-1402.e6. [DOI: 10.1016/j.joen.2019.07.010] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 06/29/2019] [Accepted: 07/01/2019] [Indexed: 01/12/2023]
|
44
|
Microbial contamination of brand new nickel-titanium endodontic instruments. LA CLINICA TERAPEUTICA 2019; 170:e258-e261. [PMID: 31304512 DOI: 10.7417/ct.2019.2144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIMS This study aims to estimate the microbial presence on the surface of different brand new NiTi endodontic instruments for clinical use. MATERIAL AND METHODS Eleven different types of NiTi rotary endodontic instruments, obtained from their fresh opened original packages, were assigned to three different groups, according to packaging type and sterilization and tested for bacterial contamination. Isolated bacteria were identified by using standard microbiological methods and then counted. Differences observed in groups were analyzed statistically by using the one-way analysis of variance (ANOVA) for dependent samples and the Tukey HSD post hoc test. RESULTS Statistical differences were found between instruments delivered in plastic boxes which bacterial count resulted higher than those obtained from instruments delivered in blisters (p<0.01). CONCLUSIONS Some brand new endodontic instruments showed degrees of bacterial contamination that both quantitatively and qualitatively deserve to be considered in clinical procedures.
Collapse
|
45
|
Cone-beam computed tomographic analysis on root and canal morphology of mandibular first permanent molar among multiracial population in Western European population. Eur J Dent 2019; 12:434-438. [PMID: 30147412 PMCID: PMC6089042 DOI: 10.4103/ejd.ejd_116_18] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Objectives: In the present study, confluent canals in the mandibular first molar's mesial root were investigated in an Italian population by means of cone-beam computed tomography (CBCT). Materials and Methods: A total of 200 molars, selected from the CBCT examinations of 130 patients who required this type of X-ray study as part of their dental treatment, were examined. The evaluated parameters were number of canals, root canal system configuration, presence of apical confluences, distance between confluences and apical foramina, which canal had a higher degree of curvature, and symmetry between left and right elements in the same individual. Statistical Analysis Used: Percentages of the cases were reported. Results: All the examined roots presented two canals. In 59% of cases, a Vertucci Type IV canal configuration was observed, while in 41% of cases, a Type II configuration was observed. Apical confluences were present in 41% of cases. The average distance between confluences and apical foramina was 2.85 mm. When confluences were present, the mesiobuccal canal showed a higher degree of curvature in 78% of cases. Symmetry in Vertucci configuration was seen in 88% of cases. Conclusions: Apical confluences in the mesial roots of mandibular molar can be present in a significantly high number of cases, and their recognition is essential to prevent the iatrogenic errors during canal instrumentation.
Collapse
|
46
|
Analysis of Fused Rooted Maxillary First and Second Molars with Merged and C-shaped Canal Configurations: Prevalence, Characteristics, and Correlations in a Saudi Arabian Population. J Endod 2019; 45:1209-1218. [DOI: 10.1016/j.joen.2019.06.009] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 05/25/2019] [Accepted: 06/25/2019] [Indexed: 11/26/2022]
|
47
|
Cone-beam computed tomography in the assessment of periapical lesions in endodontically treated teeth. Eur J Dent 2019; 12:136-143. [PMID: 29657539 PMCID: PMC5883466 DOI: 10.4103/ejd.ejd_320_17] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Objective: This study aimed to evaluate the relationship between the quality of the coronal restoration and the root canal filling on the periapical status of endodontically treated teeth using CBCT. Materials and Methods: CBCT data were obtained from the records of patients who deny any dental treatment in the 2 years prior to the CBCT examination. CBCT images (90 kVp and 7 mA, exposure time of 23 s, and a voxel size of 0.2 mm, with a field of view of 13 cm × 13 cm) of 1011 endodontically treated teeth were observed. A score was given to the quality of the root filling and the quality of the coronal restoration. Statistical Analysis Used: Data were statistically analyzed to correlate the periapical status with gender, dental group. and quality of endodontic treatment and restoration (Chi-square test with a significance level of P < 0.001). Results: Absence of periapical periodontitis was found in 54.9% of the cases. The periapical outcome was not related to gender or dental group (P > 0.05). A statistically significant factor (Chi-square test, P < 0.0001) resulted when different qualities of sealing were compared. Conclusions: CBCT showed that high-quality root canal treatments followed by an adequate coronal sealing restoration avoid the presence of periapical periodontitis in time.
Collapse
|
48
|
Root and Root Canal Morphology Differences Between Genders: A Comprehensive in-vivo CBCT Study in a Saudi Population. Acta Stomatol Croat 2019; 53:213-246. [PMID: 31749454 PMCID: PMC6820446 DOI: 10.15644/asc53/3/5] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 07/27/2019] [Indexed: 12/27/2022] Open
Abstract
OBJECTIVES To comprehensively explore the differences of all maxillary and mandibular permanent teeth in relation to number of roots, number of root canals, and root canal configuration between both genders in a Saudi Arabian population. METHODS This retrospective radiographic study comprised 208 subjects (48% males and 52% females) with a mean age 28.74±9.56 years. The CBCT images of the recruited subjects were evaluated for all permanent teeth. A careful examination was obtained by optimal visualization using all the software features. The data were analyzed using SPSS software program. Cohen's Kappa test was used for reliability and the Chi-squared test of association was used for the differences between both genders in relation to the study variables. A P-value < 0.05 was considered significant. RESULTS A total of 5254 maxillary and mandibular permanent teeth were evaluated. In relation to number of roots, there were no significant differences between both genders for all maxillary and mandibular teeth together (P= 0.064) as well as for maxillary and mandibular teeth separately (P= 0.315 and P= 0.100, respectively). A significant difference was found between males and females in relation to the number of canals of maxillary teeth (P= 0.014). For mandibular teeth, the significant level of difference was at the cut-off point (P= 0.050). For all maxillary and mandibular teeth together, the distribution among both genders was not significant (P= 0.082). The difference between both genders with regard to canal configuration of maxillary roots was highly statistically significant (P< 0.001). For mandibular teeth, the difference between males and females in relation canal configuration of anterior and premolar teeth was significant (P= 0.016) while, the difference was not significant when related to mesial roots of 1st and 2nd molars (P= 0.205). However, the difference was highly significant when related to distal roots of 1st and 2nd molars (P< 0.001). CONCLUSION No significant differences between both genders in relation to number of roots were found. Regarding the number of canals, significant differences were found only in three groups out of 14 groups of teeth with females who had a smaller number of canals than males. For canal configuration, two groups of maxillary teeth and three groups of mandibular teeth showed statistically significant differences between both genders.
Collapse
|
49
|
Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments. MATERIALS (BASEL, SWITZERLAND) 2019; 12:E2523. [PMID: 31398814 PMCID: PMC6720207 DOI: 10.3390/ma12162523] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 07/30/2019] [Accepted: 08/06/2019] [Indexed: 02/03/2023]
Abstract
The aim of this study was to investigate the role of the flat-designed surface in improving the resistance to cyclic fatigue by comparing heat-treated F-One (Fanta Dental, Shanghai, China) nickel-titanium (NiTi) rotary instruments and similar prototypes, differing only by the absence of the flat side. The null hypothesis was that there were no differences between the two tested instruments in terms of cyclic fatigue lifespan. A total of 40 new NiTi instruments (20 F-One and 20 prototypes) were tested in the present study. The instruments were rotated with the same speed (500 rpm) and torque (2 N) using an endodontic motor (Elements Motor, Kerr, Orange, CA, USA) in the same stainless steel, artificial canal (90° angle of curvature and 5 mm radius). A Wilcoxon-Mann-Whitney test was performed to assess the differences in terms of time to fracture and the length of the fractured segment between the flat- and non-flat-sided instruments. Significance was set at p = 0.05. The differences in terms of time to fracture between non-flat and flat were statistically significant (p < 0.001). In addition, the differences in terms of fractured segment length were statistically significant (p = 0.034). The results of this study highlight the importance of flat-sided design in increasing the cyclic fatigue lifespan of NiTi rotary instruments.
Collapse
|
50
|
Symmetry of root and root canal morphology of mandibular incisors: A cone-beam computed tomography study in vivo. J Clin Exp Dent 2019; 11:e527-e533. [PMID: 31346372 PMCID: PMC6645266 DOI: 10.4317/jced.55629] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 05/13/2019] [Indexed: 12/27/2022] Open
Abstract
Background Aim of this study was to analyze the root canal configuration in mandibular central and lateral incisors in vivo using cone-beam computed tomography (CBCT) imaging. Material and Methods A total of 487 mandibular central incisors and 491 mandibular lateral incisors from 250 patients were examined using CBCT imaging, previously taken for diagnosis and treatment. The number of roots, root canal system configuration, presence of apical confluences, distance between confluences and radiographic root end, symmetry between left and right elements were recorded and statistically analyzed. Results All the examined teeth presented only one root. No significant differences were found between the prevalence of two root canals in mandibular central incisors (219 teeth, 45%) compared to lateral incisors (211 teeth, 43%). Conclusions The percentage of Vertucci type II configuration was higher than expected, being more frequent than type III. Type I was the prevalent, while other configurations were present but rare. Key words:Cone-beam computed tomography, mandibular incisors, root canal anatomy, confluences.
Collapse
|