1
|
Commentary on the current status of nuclear medicine medical physics expert support in the UK. Nucl Med Commun 2024; 45:541-545. [PMID: 38716744 PMCID: PMC11075750 DOI: 10.1097/mnm.0000000000001843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 03/25/2024] [Indexed: 05/12/2024]
|
2
|
The Role of Pretherapy Quantitative Imaging and Dosimetry in Radioiodine Therapy for Advanced Thyroid Cancer. J Nucl Med 2023; 64:1125-1130. [PMID: 37116914 PMCID: PMC10315692 DOI: 10.2967/jnumed.122.264913] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 02/07/2023] [Indexed: 04/30/2023] Open
Abstract
Radioactive iodine is well established as a successful treatment for differentiated thyroid cancer (DTC), although around 15% of patients have local recurrence or develop distant metastases and may become refractory to radioactive iodine (RAI). A personalized approach to treatment, based on the absorbed radiation doses delivered and using treatments to enhance RAI uptake, has not yet been developed. Methods: We performed a multicenter clinical trial to investigate the role of selumetinib, which modulates the expression of the sodium iodide symporter, and hence iodine uptake, in the treatment of RAI-refractory DTC. The iodine uptake before and after selumetinib was quantified to assess the effect of selumetinib. The range of absorbed doses delivered to metastatic disease was calculated from pre- and posttherapy imaging, and the predictive accuracy of a theranostic approach to enable personalized treatment planning was investigated. Results: Significant inter- and intrapatient variability was observed with respect to the uptake of RAI and the effect of selumetinib. The absorbed doses delivered to metastatic lesions ranged from less than 1 Gy to 1,170 Gy. A strong positive correlation was found between the absorbed doses predicted from pretherapy imaging and those measured after therapy (r = 0.93, P < 0.001). Conclusion: The variation in outcomes from RAI therapy of DTC may be explained, among other factors, by the range of absorbed doses delivered. The ability to assess the effect of treatments that modulate RAI uptake, and to estimate the absorbed doses at therapy, introduces the potential for patient stratification using a theranostic approach. Patient-specific absorbed dose planning might be the key to more successful treatment of advanced DTC.
Collapse
|
3
|
Radiation protection aspects for alpha therapies. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2023; 67:4-13. [PMID: 36633588 DOI: 10.23736/s1824-4785.22.03501-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
The use of alpha emitting radiotherapeutics is increasing, with further growth expected due to a number of clinical trials currently running involving new alpha emitters. However, literature concerning radiation safety aspects of alpha emitting radionuclides is limited and most of the available literature concerns 223Ra. In general, the occupational exposure from alpha emitting radionuclides is expected to be low, as are doses to the public from external exposure. However, care must be taken to avoid skin contamination, inhalation, and ingestion. Not all alpha emitting radionuclides are identical, they often have very different associated decay chains and emissions. The decay chains and the manufacturing process should be carefully examined to identify any long-lived progeny or impurities. These may have an impact on the radiation safety processes required to limit occupational exposure and for waste management. Doses to the public must also be assessed, either arising directly from exposure to patients treated with radiotherapeutics, or via waste streams. Risk assessments should be in place when starting a new service covering all aspects of the preparation and administration, as well as any foreseeable incidents such as skin contamination or patient death, and the appropriate steps to take in these instances. It is imperative that with the increase in the use of alpha emitting radiotherapeutics more literature is published on radiation safety aspects, especially for new alpha emitting radiotherapeutics which often have very different characteristics than the currently established ones.
Collapse
|
4
|
Leonidas D. Marinelli: Cold War Scientist. Radiat Res 2023; 199:202-210. [PMID: 36583945 DOI: 10.1667/rade-22-00064.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 12/12/2022] [Indexed: 12/31/2022]
|
5
|
Quantification and dosimetry of small volumes including associated uncertainty estimation. EJNMMI Phys 2022; 9:86. [PMID: 36512147 DOI: 10.1186/s40658-022-00512-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 11/17/2022] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Accurate quantification of radioactivity in a source of interest relies on accurate registration between SPECT and anatomical images, and appropriate correction of partial volume effects (PVEs). For small volumes, exact registration between the two imaging modalities and recovery factors used to correct for PVE are unreliable. There is currently no guidance relating to quantification or the associated uncertainty estimation for small volumes. MATERIAL AND METHODS A method for quantification of small sources of interest is proposed, which uses multiple oversized volumes of interest. The method was applied to three Na[131I]I activity distributions where a Na[131I]I capsule was situated within a cylindrical phantom containing either zero background, uniform background or non-uniform background and to a scenario with small lesions placed in an anthropomorphic phantom. The Na[131I]I capsule and lesions were quantified using the proposed method and compared with measurements made using two alternative quantification methods. The proposed method was also applied to assess the absorbed dose delivered to a bone metastasis following [131I]mIBG therapy for neuroblastoma including the associated uncertainty estimation. RESULTS The method is accurate across a range of activities and in varied radioactivity distributions. Median percentage errors using the proposed method in no background, uniform backgrounds and non-uniform backgrounds were - 0.4%, - 0.3% and 1.7% with median associated uncertainties of 1.4%, 1.4% and 1.6%, respectively. The technique is more accurate and robust when compared to currently available alternative methods. CONCLUSIONS The proposed method provides a reliable and accurate method for quantification of sources of interest, which are less than three times the spatial resolution of the imaging system. The method may be of use in absorbed dose calculation in cases of bone metastasis, lung metastasis or thyroid remnants.
Collapse
|
6
|
Second primary malignancies induced by radioactive iodine treatment of differentiated thyroid carcinoma - a critical review and evaluation of the existing evidence. Eur J Nucl Med Mol Imaging 2022; 49:3247-3256. [PMID: 35320386 PMCID: PMC9250458 DOI: 10.1007/s00259-022-05762-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Accepted: 03/11/2022] [Indexed: 12/19/2022]
Abstract
PURPOSE Concern is growing about long-term side effects of differentiated thyroid cancer treatment, most notably radioactive iodine (RAI) therapy. However, published studies on the subject have had heterogeneous cohorts and conflicting results. This review seeks to provide an updated evaluation of published evidence, and to elucidate the risk of second primary malignancies (SPMs), especially secondary hematologic malignancies (SHMs), attributable to RAI therapy. METHODS An extensive literature search was performed in Ovid MEDLINE, Ovid MEDLINE and In-Process & Other Non-Indexed Citations, Ovid MEDLINE Epub Ahead of Print, Cochrane Central Register of Controlled Trials (CENTRAL) and PubMed. Studies regarding RAI-induced SPMs or a dose-response relationship between RAI therapy and SPMs were identified, 10 of which were eligible for the analysis. We evaluated risk of bias in each study and judged quality of evidence (QOE) across all studies using the Grading of Recommendations, Assessment, Development and Evaluations approach. RESULTS For the outcome "SPM", the relative effect (relative risk, hazard ratio, or odds ratio) of RAI vs. no RAI ranged from 1.14 to 1.84 across studies, but most results were not statistically significant. For the outcome "SHM", reported relative effects ranged from 1.30 to 2.50, with 2/3 of the studies presenting statistically significant results. In 7/8 of the studies, increased risk for SPM was shown with increasing cumulative RAI activity. QOE was "very low" regarding SPM after RAI and regarding a dose-response relationship, and "low" for SHM after RAI. CONCLUSION Based on low quality evidence, an excess risk for the development of SPM cannot be excluded but is expected to be small.
Collapse
|
7
|
A Systematic Review and Meta-Analysis of the Relationship Between the Radiation Absorbed Dose to the Thyroid and Response in Patients Treated with Radioiodine for Graves' Disease. Thyroid 2021; 31:1829-1838. [PMID: 34598656 PMCID: PMC8721505 DOI: 10.1089/thy.2021.0302] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Background: Patients with Graves' disease are commonly treated with radioiodine. There remains controversy over whether the aim of treatment should be to achieve euthyroidism or hypothyroidism, and whether treatments should be administered with standard levels of radioactivity or personalized according to the radiation absorbed doses delivered to the thyroid. The aim of this review was to investigate whether a relationship exists between radiation absorbed dose and treatment outcome. Methods: A systematic review and meta-analysis of all reports published before February 13, 2020, were performed using PubMed, Web of Science, OVID MEDLINE, and Embase. Proportion of patients achieving nonhyperthyroid status was the primary outcome. Secondary outcomes were proportion of patients who were specifically euthyroid or hypothyroid. A random-effects meta-analysis of proportions was performed for primary and secondary outcomes, and the impact of the radiation absorbed dose on treatment outcome was assessed through meta-regression. The study is registered with PROSPERO (CRD42020175010). Results: A total of 1122 studies were identified of which 15, comprising 2303 Graves' disease patients, were eligible for the meta-analysis. A strong association was found between radiation absorbed dose and nonhyperthyroid and hypothyroid outcomes (odds ratio [OR] = 1.11 [95% confidence interval {CI} 1.08-1.14] and OR = 1.09 [CI 1.06-1.12] per 10 Gy increase). Higher rates of euthyroid outcome were found for radiation absorbed doses within the range 120-180 Gy when compared with outside this range (n = 1172, OR = 2.50 [CI 1.17-5.35], p = 0.018). A maximum euthyroid response of 38% was identified at a radiation absorbed dose of 128 Gy. Conclusions: The presented radiation absorbed dose-response relationships can facilitate personalized treatment planning for radioiodine treatment of patients with Graves' disease. Further studies are required to determine how patient-specific covariates can inform personalized treatments.
Collapse
|
8
|
Adjustment of the iodine ICRP population pharmacokinetic model for the use in thyroid cancer patients after thyroidectomy. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:1034-1044. [PMID: 34261047 DOI: 10.1088/1361-6498/ac149a] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Accepted: 07/14/2021] [Indexed: 06/13/2023]
Abstract
Biokinetic models developed for healthy humans are not appropriate to describe biokinetics in thyroid cancer patients following thyroidectomy. The aim of this study was to adjust the population model for iodine proposed by the International Commission on Radiological Protection (ICRP) for the use in these patients. Rate constants of the ICRP publication 128 model for iodine were adjusted using the population modelling software package Monolix to describe activity retention in whole-body, thyroid, blood and protein-bound iodine observed in 23 patients. The new set of rate constants was compared to the four uptake scenarios proposed in ICRP publication 128. Flow from the inorganic iodide in blood compartment into the first thyroid compartment decreases to 0.15 d-1compared to a value of 7.27 d-1for the ICRP publication 128 model with a medium uptake. The transfer from first to second thyroid compartments and the outflow from the second thyroid compartment increases. An increased turnover rate of extrathyroidal organic iodine is observed. The rate constant from inorganic iodide in blood to kidney was also adjusted. Overall a good agreement was found between the adjusted model and the activity retention in thyroid cancer patients. The adjustment of population pharmacokinetic models to describe the biokinetic properties of specific patient populations for therapeutic radiopharmaceuticals is essential to capture the changes in biokinetics. The proposed set of rate constants for the established ICRP publication 128 model can be used to more accurately assess radiation protection requirements for the treatment of thyroid cancer patients using radioiodine.
Collapse
|
9
|
Comparison of 90Y SIRT predicted and delivered absorbed doses using a PSF conversion method. Phys Med 2021; 89:1-10. [PMID: 34339928 PMCID: PMC8501309 DOI: 10.1016/j.ejmp.2021.07.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 06/23/2021] [Accepted: 07/19/2021] [Indexed: 12/24/2022] Open
Abstract
PURPOSE The aims of this study were to develop and apply a method to correct for the differences in partial volume effects of pre-therapy Technetium-99 m (99mTc)-MAA SPECT and post-therapy Yttrium-90 (90Y) bremsstrahlung SPECT imaging in selective internal radiation therapy, and to use this method to improve quantitative comparison of predicted and delivered 90Y absorbed doses. METHODS The spatial resolution of 99mTc SPECT data was converted to that of 90Y SPECT data using a function calculated from 99mTc and 90Y point spread functions. This resolution conversion method (RCM) was first applied to 99mTc and 90Y SPECT phantom data to validate the method, and then to clinical data to assess the power of 99mTc SPECT imaging to predict the therapeutic absorbed dose. RESULTS The maximum difference between absorbed doses to phantom spheres was 178%. This was reduced to 27% after the RCM was applied. The clinical data demonstrated differences within 38% for mean absorbed doses delivered to the normal liver, which were reduced to 20% after application of the RCM. Analysis of clinical data showed that therapeutic absorbed doses delivered to tumours greater than 100 cm3 were predicted to within 52%, although there were differences of up to 210% for smaller tumours, even after the RCM was applied. CONCLUSIONS The RCM was successfully verified using phantom data. Analysis of the clinical data established that the 99mTc pre-therapy imaging was predictive of the 90Y absorbed dose to the normal liver to within 20%, but had poor predictability for tumours smaller than 100 cm3.
Collapse
|
10
|
RADAR Guide: Standard Methods for Calculating Radiation Doses for Radiopharmaceuticals Part 2. Data Analysis and Dosimetry. J Nucl Med 2021; 63:485-492. [PMID: 34353873 DOI: 10.2967/jnumed.121.262034] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 05/05/2021] [Indexed: 11/16/2022] Open
Abstract
This paper presents standardized methods for performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. Special models for calculating time-activity integrals (urinary bladder, intestines) are also reviewed. This document can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates, from animal or human data.
Collapse
|
11
|
RADAR Guide: Standard Methods for Calculating Radiation Doses for Radiopharmaceuticals Part 1. Collection of Data for Radiopharmaceutical Dosimetry. J Nucl Med 2021; 63:316-322. [PMID: 34353875 DOI: 10.2967/jnumed.120.259200] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 05/05/2021] [Indexed: 11/16/2022] Open
Abstract
This paper presents standardized methods for collecting data to be used in performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. This document can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates, from animal or human data.
Collapse
|
12
|
Recommendations for Multicentre Clinical Trials Involving Dosimetry for Molecular Radiotherapy. Clin Oncol (R Coll Radiol) 2021; 33:131-136. [PMID: 33342617 PMCID: PMC7818526 DOI: 10.1016/j.clon.2020.12.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 11/06/2020] [Accepted: 12/02/2020] [Indexed: 11/17/2022]
Abstract
Multicentre clinical trials involving a dosimetry component are becoming more prevalent in molecular radiotherapy and are essential to generate the evidence to support individualised approaches to treatment planning and to ensure that sufficient patients are recruited to achieve the statistical significance required. Quality assurance programmes should be considered to support the standardisation required to achieve meaningful results. Trials should be designed to ensure that dosimetry results from image acquisition systems across centres are comparable by incorporating steps to standardise the methodologies used for the quantification of images and dosimetry. Furthermore, it is essential to assess the expertise and resources available at each participating site prior to trial commencement. A quality assurance plan should be drawn up and training provided if necessary. Standardisation of quantification and dosimetry methodologies used in a trial are essential to ensure that results from different centres may be collated. In addition, appropriate uncertainty analysis should be carried out to correct for differences in methodologies between centres. Recommendations are provided to support dosimetry studies based on the experience of several previous and ongoing multicentre trials.
Collapse
|
13
|
Uncertainty analysis of tumour absorbed dose calculations in molecular radiotherapy. EJNMMI Phys 2020; 7:63. [PMID: 33044651 PMCID: PMC7550507 DOI: 10.1186/s40658-020-00328-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 09/16/2020] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Internal dosimetry evaluation consists of a multi-step process ranging from imaging acquisition to absorbed dose calculations. Assessment of uncertainty is complicated and, for that reason, it is commonly ignored in clinical routine. However, it is essential for adequate interpretation of the results. Recently, the EANM published a practical guidance on uncertainty analysis for molecular radiotherapy based on the application of the law of propagation of uncertainty. In this study, we investigated the overall uncertainty on a sample of a patient following the EANM guidelines. The aim of this study was to provide an indication of the typical uncertainties that may be expected from performing dosimetry, to determine parameters that have the greatest effect on the accuracy of calculations and to consider the potential improvements that could be made if these effects were reduced. RESULTS Absorbed doses and the relative uncertainties were calculated for a sample of 49 patients and a total of 154 tumours. A wide range of relative absorbed dose uncertainty values was observed (14-102%). Uncertainties associated with each quantity along the absorbed dose calculation chain (i.e. volume, recovery coefficient, calibration factor, activity, time-activity curve fitting, time-integrated activity and absorbed dose) were estimated. An equation was derived to describe the relationship between the uncertainty in the absorbed dose and the volume. The largest source of error was the VOI delineation. By postulating different values of FWHM, the impact of the imaging system spatial resolution on the uncertainties was investigated. DISCUSSION To the best of our knowledge, this is the first analysis of uncertainty in molecular radiotherapy based on a cohort of clinical cases. Wide inter-lesion variability of absorbed dose uncertainty was observed. Hence, a proper assessment of the uncertainties associated with the calculations should be considered as a basic scientific standard. A model for a quick estimate of uncertainty without implementing the entire error propagation schema, which may be useful in clinical practice, was presented. Ameliorating spatial resolution may be in future the key factor for accurate absorbed dose assessment.
Collapse
|
14
|
Setting up a quantitative SPECT imaging network for a European multi-centre dosimetry study of radioiodine treatment for thyroid cancer as part of the MEDIRAD project. EJNMMI Phys 2020; 7:61. [PMID: 33030702 PMCID: PMC7544799 DOI: 10.1186/s40658-020-00332-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 09/29/2020] [Indexed: 12/29/2022] Open
Abstract
Background Differentiated thyroid cancer has been treated with radioiodine for almost 80 years, although controversial questions regarding radiation-related risks and the optimisation of treatment regimens remain unresolved. Multi-centre clinical studies are required to ensure recruitment of sufficient patients to achieve the statistical significance required to address these issues. Optimisation and standardisation of data acquisition and processing are necessary to ensure quantitative imaging and patient-specific dosimetry. Material and methods A European network of centres able to perform standardised quantitative imaging of radioiodine therapy of thyroid cancer patients was set-up within the EU consortium MEDIRAD. This network will support a concurrent series of clinical studies to determine accurately absorbed doses for thyroid cancer patients treated with radioiodine. Five SPECT(/CT) systems at four European centres were characterised with respect to their system volume sensitivity, recovery coefficients and dead time. Results System volume sensitivities of the Siemens Intevo systems (crystal thickness 3/8″) ranged from 62.1 to 73.5 cps/MBq. For a GE Discovery 670 (crystal thickness 5/8″) a system volume sensitivity of 92.2 cps/MBq was measured. Recovery coefficients measured on three Siemens Intevo systems show good agreement. For volumes larger than 10 ml, the maximum observed difference between recovery coefficients was found to be ± 0.02. Furthermore, dead-time coefficients measured on two Siemens Intevo systems agreed well with previously published dead-time values. Conclusions Results presented here provide additional support for the proposal to use global calibration parameters for cameras of the same make and model. This could potentially facilitate the extension of the imaging network for further dosimetry-based studies.
Collapse
|
15
|
Abstract
Quality control tests of molecular imaging systems are hampered by the complexity of phantom preparation. It is proposed that radioisotopes can be directly incorporated into photo-polymer resins. Use of the radio-polymer in a 3D printer allows phantoms with more complex and reliable activity distributions to be produced whilst simplifying source preparation. Initial tests have been performed to determine the practicality of integrating Tc-99m into a photo-polymer and example phantoms produced to test suitability for quality control. Samples of build and support resins were extracted from the print cartridges of an Objet30Pro Polyjet 3D printer. The response of the resin to external factors including ionising radiation, light and dilution with Tc-99m pertechnetate were explored. After success of the initial tests the radio-polymer was used in the production of different phantoms. Radionuclide dose calibrator and gamma camera acquisitions of the phantoms were used to test accuracy of activity concentration, print consistency, uniformity and heterogeneous reproducibility. Tomographic phantoms were also produced including a uniform hot sphere, a complex configuration of spheres and interlacing torus's and a hot rod phantom. The coefficient of variation between repeat prints of a 12 g disk phantom was 0.08%. Measured activity within the disks agreed to within 98 ± 2% of the expected activity based on initial resin concentration. Gamma camera integral uniformity measured across a 3D printed flood field phantom was 5.2% compared to 6.0% measured with a commercial Co-57 flood source. Heterogeneous distributions of activity were successfully reproduced for both 2D and 3D imaging phantoms. Count concentration across regions of heterogeneity agreed with the planned activity assigned to those regions on the phantom design. 3D printing of radioactive phantoms has been successfully demonstrated and is a promising application for quality control of Positron Emission Tomography and Single Photon Emission Computed Tomography systems.
Collapse
|
16
|
Quantitative Dual-Isotope Planar Imaging of Thorium-227 and Radium-223 Using Defined Energy Windows. Cancer Biother Radiopharm 2020; 35:530-539. [PMID: 32429699 PMCID: PMC7475104 DOI: 10.1089/cbr.2019.3554] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Introduction: Thorium-227 is an alpha-emitting radioisotope with potential therapeutic applications in targeted alpha therapy. Thorium-227 decays to Radium-223, which may have an independent biodistribution to that of the parent Thorium-227 radiopharmaceutical. Quantitative in vivo imaging with sodium iodide (NaI) detectors is challenging due to cross-talk between neighboring γ-photopeaks as well as scattered γ-photons. The aim of this work was to validate the use of a spectral analysis technique to estimate the activity of each isotope within a region of interest applied to a pair of conjugate view planar acquisitions, acquired at multiple energy windows. Methods: Energy spectra per unit activity arising from unscattered Thorium-227 photons and Radium-223 photons as well as from scattered photons were modeled. These spectra were scaled until the combination of these component spectra resulted in the closest match to the measured data in four energy windows. Results: Measured estimates of activity followed the known decay curves in phantoms representative of a human torso. The mean errors in estimating Thorium-227 and Radium-223 were 5.1% (range −8.0% to 40.0%) and 3.4% (range −50.0% to 48.7%), respectively. The differences between the integrals of the theoretical and estimated time activity curve were <10% for both Thorium-227 and Radium-223. Conclusion: γ-camera quantification of Thorium-227 and Radium-223 can be achieved by using multiple energy window acquisitions.
Collapse
|
17
|
Physics aspects of setting up a multicenter clinical trial involving internal dosimetry of radioiodine treatment of differentiated thyroid cancer. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2019; 63:271-277. [PMID: 31315346 DOI: 10.23736/s1824-4785.19.03202-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2024]
Abstract
The field of molecular radiotherapy is expanding rapidly, with the advent of many new radiotherapeutics for the treatment of common as well as for rare cancers. Treatment outcome is dependent on the absorbed doses delivered to target volumes and to healthy organs-at-risk, which are shown to vary widely from fixed administrations of activity. There have been significant developments in quantitative imaging and internal dosimetry in recent years, although clinical implementation of these methods has been slow in comparison with external beam radiotherapy, partly due to there being relatively few patients treated at single centers. Multicenter clinical trials are therefore essential to acquire the data required to ensure best practice and to develop the personalized treatment planning that this area is well suited to, due to the unrivalled opportunity to image the therapeutic drug in vivo. Initial preparation for such trials requires a significant effort in terms of resources and trial design. Imaging systems in participating centers must be characterized and set up for quantitative imaging to allow for collation of data. Data transfer for centralized processing is usually necessary but is hindered in some cases by data protection regulations and local logistics. Recent multicenter clinical trials involving radioiodine therapy have begun to establish the procedures necessary for quantitative SPECT imaging in a multicenter setting using standard and anthropomorphic phantoms. The establishment of national and international multicenter imaging and dosimetry networks will provide frameworks to develop and harmonize best practice with existing therapeutic procedures and to ensure rapid and optimized clinical implementation of new radiotherapeutics across all centers of excellence that offer molecular radiotherapy. This will promote networks and collaborations that can provide a sound basis for further developments and will ensure that nuclear medicine maintains a key role in future developments.
Collapse
|
18
|
Spect perfusion imaging versus CT for predicting radiation injury to normal lung in lung cancer patients. Br J Radiol 2019; 92:20190184. [PMID: 31287737 PMCID: PMC6732923 DOI: 10.1259/bjr.20190184] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 05/07/2019] [Accepted: 06/03/2019] [Indexed: 12/02/2022] Open
Abstract
OBJECTIVES In non-small cell lung cancer (NSCLC) patients, to establish whether the fractional volumes of irradiated anatomic or perfused lung differed between those with and without deteriorating lung function or radiation associated lung injury (RALI). METHODS 48 patients undergoing radical radiotherapy for NSCLC had a radiotherapy-planning CT scan and single photon emission CT lung perfusion imaging (99mTc-labelled macroaggregate albumin). CT defined the anatomic and the single photon emission CT scan (co-registered with CT) identified the perfused (threshold 20 % of maximum) lung volumes. Fractional volumes of anatomic and perfused lung receiving more than 5, 10, 13, 20, 30, 40, 50 Gy were compared between patients with deteriorating (>median decline) vs stable ( RESULTS Fractional volumes of anatomic and perfused lung receiving more than 10, 13 and 20 Gy were significantly higher in patients with deteriorating vs stable FEV1 ( p = 0.005, 0.005 and 0.025 respectively) but did not differ for higher doses of radiation (>30, 40, 50 Gy). Fractional volumes of anatomic and perfused lung receiving > 10 Gy best predicted decline in FEV1 (Area under receiver operating characteristic curve (Az = 0.77 and 0.76 respectively); sensitivity/specificity 75%/81 and 80%/71%) for a 32.7% anatomic and 33.5% perfused volume cut-off. Irradiating an anatomic fractional volume of 4.7% to > 50 Gy had a sensitivity/specificity of 83%/89 % for indicating RALI (Az = 0.83). CONCLUSION A 10-20 Gy radiation dose to anatomic or perfused lung results in decline in FEV1. A fractional anatomic volume of >5% receiving >50 Gy influences development of RALI. ADVANCES IN KNOWLEDGE Extent of low-dose radiation to normal lung influences functional respiratory decline.
Collapse
|
19
|
Characterisation of the attenuation properties of 3D-printed tungsten for use in gamma camera collimation. EJNMMI Phys 2019; 6:1. [PMID: 30617816 PMCID: PMC6323062 DOI: 10.1186/s40658-018-0238-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Accepted: 12/14/2018] [Indexed: 11/10/2022] Open
Abstract
Background The aim of this work was to characterise the attenuation properties of 3D-printed tungsten and to assess the feasibility for its use in gamma camera collimator manufacture. Method 3D-printed tungsten disks were produced using selective laser melting (SLM). Measurements of attenuation were made through increasing numbers of disks for a Tc-99m (140 keV) and I-131 (364 keV) source. The technique was validated by repeating the measurements with lead samples. Resolution measurements were also made with a SLM tungsten collimator and compared to Monte Carlo simulations of the experimental setup. Different collimator parameters were simulated and compared against the physical measurements to investigate the effect on image quality. Results The measured disk thicknesses were on average 20% above the specified disk thicknesses. The measured attenuation for the tungsten samples were lower than the theoretical value determined from the National Institute of Standards and Technology (NIST) cross-sectional database (Berger and Hubbell, XCOM: photon cross-sections on a personal computer, 1987). The laser scan strategy had a significant influence on material attenuation (up to 40% difference). Results of these attenuation measurements indicate that the density of the SLM material is lower than the raw tungsten density. However, an improved performance compared to a lead collimator was observed. The SLM tungsten collimator was adequately simulated as 80% density and 110% septal thickness. Scatter and septal penetration were 17% less than a similar lead collimator and 33% greater than tungsten at 100% density. Conclusions SLM manufacture of tungsten collimators is feasible. Attenuation properties of SLM tungsten are superior to the lead alternative and the opportunity for bespoke collimator design is appealing.
Collapse
|
20
|
EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations. Eur J Nucl Med Mol Imaging 2018; 45:2456-2474. [PMID: 30218316 PMCID: PMC6208822 DOI: 10.1007/s00259-018-4136-7] [Citation(s) in RCA: 110] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 08/14/2018] [Indexed: 11/30/2022]
Abstract
A framework is proposed for modelling the uncertainty in the measurement processes constituting the dosimetry chain that are involved in internal absorbed dose calculations. The starting point is the basic model for absorbed dose in a site of interest as the product of the cumulated activity and a dose factor. In turn, the cumulated activity is given by the area under a time-activity curve derived from a time sequence of activity values. Each activity value is obtained in terms of a count rate, a calibration factor and a recovery coefficient (a correction for partial volume effects). The method to determine the recovery coefficient and the dose factor, both of which are dependent on the size of the volume of interest (VOI), are described. Consideration is given to propagating estimates of the quantities concerned and their associated uncertainties through the dosimetry chain to obtain an estimate of mean absorbed dose in the VOI and its associated uncertainty. This approach is demonstrated in a clinical example.
Collapse
|
21
|
Abstract
Objective The aim of this retrospective study was to assess the long-term outcome of a personalized dosimetry approach in Graves’ disease aiming to render patients euthyroid from a planned thyroid absorbed dose of 60 Gy. Patients and methods A total of 284 patients with Graves’ disease were followed prospectively following administration of radioiodine calculated to deliver an absorbed dose of 60 Gy. Patients with cardiac disease were excluded. Outcomes were analysed at yearly intervals for up to 10 years with a median follow-up of 37.5 months. Results A single radioiodine administration was sufficient to render a patient either euthyroid or hypothyroid in 175 (62%) patients, the remainder requiring further radioiodine. The median radioactivity required to deliver 60 Gy was 77 MBq. Less than 2% patients required 400–600 MBq, the standard activity administered in many centres. In the cohort receiving a single administration, 38, 32 and 26% were euthyroid on no specific thyroid medication at 3, 5 and 10 years, respectively. Larger thyroid volumes were associated with the need for further therapy. The presence of nodules on ultrasonography did not adversely affect treatment outcome. Conclusion A personalized dosimetric approach delayed the long-term onset of hypothyroidism in 26% of patients. This was achieved using much lower administered activities than currently recommended. Future studies will aim to identify those patients who would benefit most from this approach.
Collapse
|
22
|
Bone lesion absorbed dose profiles in patients with metastatic prostate cancer treated with molecular radiotherapy. Br J Radiol 2018; 91:20170795. [PMID: 29293372 PMCID: PMC5966004 DOI: 10.1259/bjr.20170795] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 12/06/2017] [Accepted: 12/21/2017] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE The aim of this study was to calculate the range of absorbed doses that could potentially be delivered by a variety of radiopharmaceuticals and typical fixed administered activities used for bone pain palliation in a cohort of patients with metastatic castration-resistant prostate cancer (mCRPC). The methodology for the extrapolation of the biodistribution, pharmacokinetics and absorbed doses from a given to an alternative radiopharmaceutical is presented. METHODS Sequential single photon emission CT images from 22 patients treated with 5 GBq of 186Re-HEDP were used to extrapolate the time-activity curves for various radiopharmaceuticals. Cumulated activity distributions for the delivered and extrapolated treatment plans were converted into absorbed dose distributions using the convolution dosimetry method. The lesion absorbed doses obtained for the different treatments were compared using the patient population distributions and cumulative dose-volume histograms. RESULTS The median lesion absorbed doses across the patient cohort ranged from 2.7 Gy (range: 0.6-11.8 Gy) for 1100 MBq of 166Ho-DOTMP to 21.8 Gy (range: 4.5-117.6 Gy) for 150 MBq of 89Sr-dichloride. 32P-Na3PO4, 153Sm-EDTMP, 166Ho-DOTMP, 177Lu-EDTMP and 188Re-HEDP would have delivered 41, 32, 85, 20 and 64% lower absorbed doses, for the typical administered activities as compared to 186Re-HEDP, respectively, whilst 89Sr-dichloride would have delivered 25% higher absorbed doses. CONCLUSION For the patient cohort studied, a wide range of absorbed doses would have been delivered for typical administration protocols in mCRPC. The methodology presented has potential use for emerging theragnostic agents. Advances in knowledge: The same patient cohort can receive a range of lesion absorbed doses from typical molecular radiotherapy treatments for patients with metastatic prostate cancer, highlighting the need to establish absorbed dose response relationships and to treat patients according to absorbed dose instead of using fixed administered activities.
Collapse
|
23
|
Reply to 'Single high dose versus repeated bone-targeted radionuclide therapy'. Eur J Nucl Med Mol Imaging 2018; 45:515-517. [PMID: 29247283 DOI: 10.1007/s00259-017-3902-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Excretion and whole-body retention of radium-223 dichloride administered for the treatment of bone metastases from castration resistant prostate cancer. Nucl Med Commun 2018; 39:125-130. [PMID: 29189490 DOI: 10.1097/mnm.0000000000000783] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE The aim of the study was to determine the fraction of administered activity that was excreted and retained by a small cohort of patients who each received treatment with radium-223 dichloride (Ra). Ra is an α-emitting radionuclide that has been approved for use in the treatment of bone metastases that are secondary to castration resistant prostate cancer. PATIENTS AND METHODS Six patients received two weight-based administrations of Ra 6 weeks apart. Activity excreted in the urine and faeces during the first 48 h following each treatment was assessed by direct counting of the excreta. During the same period the whole-body retention of Ra was also determined using a single probe counting system. The results of the excreta counting and the whole-body counting were compared to determine whether whole-body counting was a suitable surrogate for assessing excretion. Further whole-body retention counts were made at around 3, 4, 7 and 42 days following treatment. RESULTS Patterns of excretion and retention of Ra varied significantly between patients, but were similar for each patient's pair of treatments. The cumulative maximum activity excreted in the initial 8-h period following the Ra administration was 2.6% that increased to 39% at 48 h. The median excreted activity at ~1 and 6 weeks after treatment was 70 and 86%, respectively. Skeletal retention of Ra at 6 weeks ranged from 11 to 60% of the administered activity.
Collapse
|
25
|
From fixed activities to personalized treatments in radionuclide therapy: lost in translation? Eur J Nucl Med Mol Imaging 2017; 45:152-154. [PMID: 29080096 PMCID: PMC5700228 DOI: 10.1007/s00259-017-3859-1] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Accepted: 10/12/2017] [Indexed: 11/02/2022]
|
26
|
The potential of 223Ra and 18F-fluoride imaging to predict bone lesion response to treatment with 223Ra-dichloride in castration-resistant prostate cancer. Eur J Nucl Med Mol Imaging 2017; 44:1832-1844. [PMID: 28612079 PMCID: PMC6175045 DOI: 10.1007/s00259-017-3744-y] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Accepted: 05/25/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE The aims of this study were to calculate bone lesion absorbed doses resulting from a weight-based administration of 223Ra-dichloride, to assess the relationship between those doses and corresponding 18F-fluoride uptake and to assess the potential of quantitative 18F-fluoride imaging to predict response to treatment. METHODS Five patients received two intravenous injections of 223Ra-dichloride, 6 weeks apart, at 110 kBq/kg whole-body weight. The biodistribution of 223Ra in metastatic lesions as a function of time after administration as well as associated lesion dosimetry were determined from serial 223Ra scans. PET/CT imaging using 18F-fluoride was performed prior to the first treatment (baseline), and at week 6 immediately before the second treatment and at week 12 after baseline. RESULTS Absorbed doses to metastatic bone lesions ranged from 0.6 Gy to 44.1 Gy. For individual patients, there was an average factor difference of 5.3 (range 2.5-11.0) between the maximum and minimum lesion dose. A relationship between lesion-absorbed doses and serial changes in 18F-fluoride uptake was demonstrated (r2 = 0.52). A log-linear relationship was demonstrated (r2 = 0.77) between baseline measurements of 18F-fluoride uptake prior to 223Ra-dichloride therapy and changes in uptake 12 weeks after the first cycle of therapy. Correlations were also observed between both 223Ra and 18F-fluoride uptake in lesions (r = 0.75) as well as between 223Ra absorbed dose and 18F-fluoride uptake (r = 0.96). CONCLUSIONS There is both inter-patient and intra-patient heterogeneity of absorbed dose estimates to metastatic lesions. A relationship between 223Ra lesion absorbed dose and subsequent lesion response was observed. Analysis of this small group of patients suggests that baseline uptake of 18F-fluoride in bone metastases is significantly correlated with corresponding uptake of 223Ra, the associated 223Ra absorbed dose and subsequent lesion response to treatment.
Collapse
|
27
|
Imaging and dosimetry for radium-223: the potential for personalized treatment. Br J Radiol 2017; 90:20160748. [PMID: 28654303 PMCID: PMC5858794 DOI: 10.1259/bjr.20160748] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 03/29/2017] [Accepted: 05/03/2017] [Indexed: 11/14/2022] Open
Abstract
Radium-223 (223Ra) offers a new option for the treatment of bone metastases from prostate cancer. As cancer treatment progresses towards personalization, the potential for an individualized approach is exemplified in treatments with radiotherapeutics due to the unique ability to image in vivo the uptake and retention of the therapeutic agent. This is unmatched in any other field of medicine. Currently, 223Ra is administered according to standard fixed administrations, modified according to patient weight. Although gamma emissions comprise only 1% of the total emitted energy, there are increasing reports that quantitative imaging is feasible and can facilitate patient-specific dosimetry. The aim of this article is to review the application of imaging and dosimetry for 223Ra and to consider the potential for treatment optimization accordingly, in order to ensure clinical and cost effectiveness of this promising agent.
Collapse
|
28
|
Comparison of Empiric Versus Dosimetry-Guided Radioiodine Therapy: The Devil Is in the Details. J Nucl Med 2017; 58:862. [PMID: 28183989 DOI: 10.2967/jnumed.116.186643] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
29
|
A radiobiological model of metastatic burden reduction for molecular radiotherapy: application to patients with bone metastases. Phys Med Biol 2017; 62:2859-2870. [PMID: 28291739 PMCID: PMC5953197 DOI: 10.1088/1361-6560/aa5e6f] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 01/05/2017] [Accepted: 02/06/2017] [Indexed: 12/26/2022]
Abstract
Skeletal tumour burden is a biomarker of prognosis and survival in cancer patients. This study proposes a novel method based on the linear quadratic model to predict the reduction in metastatic tumour burden as a function of the absorbed doses delivered from molecular radiotherapy treatments. The range of absorbed doses necessary to eradicate all the bone lesions and to reduce the metastatic burden was investigated in a cohort of 22 patients with bone metastases from castration-resistant prostate cancer. A metastatic burden reduction curve was generated for each patient, which predicts the reduction in metastatic burden as a function of the patient mean absorbed dose, defined as the mean of all the lesion absorbed doses in any given patient. In the patient cohort studied, the median of the patient mean absorbed dose predicted to reduce the metastatic burden by 50% was 89 Gy (interquartile range: 83-105 Gy), whilst a median of 183 Gy (interquartile range: 107-247 Gy) was found necessary to eradicate all metastases in a given patient. The absorbed dose required to eradicate all the lesions was strongly correlated with the variability of the absorbed doses delivered to multiple lesions in a given patient (r = 0.98, P < 0.0001). The metastatic burden reduction curves showed a potential large reduction in metastatic burden for a small increase in absorbed dose in 91% of patients. The results indicate the range of absorbed doses required to potentially obtain a significant survival benefit. The metastatic burden reduction method provides a simple tool that could be used in routine clinical practice for patient selection and to indicate the required administered activity to achieve a predicted patient mean absorbed dose and reduction in metastatic tumour burden.
Collapse
|
30
|
Phase I/II trials of 186Re-HEDP in metastatic castration-resistant prostate cancer: post-hoc analysis of the impact of administered activity and dosimetry on survival. Eur J Nucl Med Mol Imaging 2017; 44:620-629. [PMID: 27770145 PMCID: PMC5323472 DOI: 10.1007/s00259-016-3543-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Accepted: 09/30/2016] [Indexed: 12/13/2022]
Abstract
PURPOSE To investigate the role of patient-specific dosimetry as a predictive marker of survival and as a potential tool for individualised molecular radiotherapy treatment planning of bone metastases from castration-resistant prostate cancer, and to assess whether higher administered levels of activity are associated with a survival benefit. METHODS Clinical data from 57 patients who received 2.5-5.1 GBq of 186Re-HEDP as part of NIH-funded phase I/II clinical trials were analysed. Whole-body and SPECT-based absorbed doses to the whole body and bone lesions were calculated for 22 patients receiving 5 GBq. The patient mean absorbed dose was defined as the mean of all bone lesion-absorbed doses in any given patient. Kaplan-Meier curves, log-rank tests, Cox's proportional hazards model and Pearson's correlation coefficients were used for overall survival (OS) and correlation analyses. RESULTS A statistically significantly longer OS was associated with administered activities above 3.5 GBq in the 57 patients (20.1 vs 7.1 months, hazard ratio: 0.39, 95 % CI: 0.10-0.58, P = 0.002). A total of 379 bone lesions were identified in 22 patients. The mean of the patient mean absorbed dose was 19 (±6) Gy and the mean of the whole-body absorbed dose was 0.33 (±0.11) Gy for the 22 patients. The patient mean absorbed dose (r = 0.65, P = 0.001) and the whole-body absorbed dose (r = 0.63, P = 0.002) showed a positive correlation with disease volume. Significant differences in OS were observed for the univariate group analyses according to disease volume as measured from SPECT imaging of 186Re-HEDP (P = 0.03) and patient mean absorbed dose (P = 0.01), whilst only the disease volume remained significant in a multivariable analysis (P = 0.004). CONCLUSION This study demonstrated that higher administered activities led to prolonged survival and that for a fixed administered activity, the whole-body and patient mean absorbed doses correlated with the extent of disease, which, in turn, correlated with survival. This study shows the importance of patient stratification to establish absorbed dose-response correlations and indicates the potential to individualise treatment of bone metastases with radiopharmaceuticals according to patient-specific imaging and dosimetry.
Collapse
|
31
|
Abstract
Cancer has been treated with radiopharmaceuticals for 80 years. A recent National Cancer Research Institute report from the Clinical and Translational Radiotherapy Research Working Group reviews the current status of molecular radiotherapy and has highlighted the barriers to and opportunities for increased research activities. The report recommends a number of actions to promote this field, which in the dawning age of personalized medicine and theragnostics is of increasing importance, particularly with the clinical introduction of a range of new commercial radiotherapeutics at costs in line with those seen for conventional chemotherapeutics. These recommendations recognize the importance of a multidisciplinary approach to the development of molecular radiotherapy and the particular need for investment in radiopharmacies and personalized dosimetry. There are many areas to be investigated including adaptive treatment planning, the use of radiosensitizers and translational radiation biology. Progress in these areas will result in significant patient benefit and more cost-effective use of increasingly expensive therapeutic radiopharmaceuticals. A concerted effort from the community, from funding bodies and from health service providers is now needed to address the scientific and logistical changes necessary to realize the potential offered by this currently underused treatment modality.
Collapse
|
32
|
InfuShield: a shielded enclosure for administering therapeutic radioisotope treatments using standard syringe pumps. Nucl Med Commun 2017; 38:266-272. [PMID: 28187040 PMCID: PMC5318158 DOI: 10.1097/mnm.0000000000000634] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2016] [Revised: 11/13/2016] [Accepted: 11/22/2016] [Indexed: 12/02/2022]
Abstract
The administration of radionuclide therapies presents significant radiation protection challenges. The aim of this work was to develop a delivery system for intravenous radioisotope therapies to substantially moderate radiation exposures to staff and operators. A novel device (InfuShield) was designed and tested before being used clinically. The device consists of a shielded enclosure which contains the therapeutic activity and, through the hydraulic action of back-to-back syringes, allows the activity to be administered using a syringe pump external to the enclosure. This enables full access to the pump controls while simultaneously reducing dose to the operator. The system is suitable for use with all commercially available syringe pumps and does not require specific consumables, maximising both the flexibility and economy of the system. Dose rate measurements showed that at key stages in an I mIBG treatment procedure, InfuShield can reduce dose to operators by several orders of magnitude. Tests using typical syringes and infusion speeds show no significant alteration in administered flow rates (maximum of 1.2%). The InfuShield system provides a simple, safe and low cost method of radioisotope administration.
Collapse
|
33
|
Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT. EJNMMI Phys 2016; 3:17. [PMID: 27495914 PMCID: PMC4975728 DOI: 10.1186/s40658-016-0151-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Accepted: 07/26/2016] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD The phantom design was based on anatomical data obtained from a T1-weighted volume-interpolated breath-hold examination (VIBE) on a Siemens Aera 1.5 T MRI scanner. The liver, lungs and abdominal trunk were segmented using the Hermes image processing workstation. Organ volumes were then uploaded to the Delft Visualization and Image processing Development Environment for smoothing and surface rendering. Triangular meshes defining the iso-surfaces were saved as stereo lithography (STL) files and imported into the Autodesk® Meshmixer software. Organ volumes were subtracted from the abdomen and a removable base designed to allow access to the liver cavity. Connection points for placing lesion inserts and filling holes were also included. The phantom was manufactured using a Stratasys Connex3 PolyJet 3D printer. The printer uses stereolithography technology combined with ink jet printing. Print material is a solid acrylic plastic, with similar properties to polymethylmethacrylate (PMMA). RESULTS Measured Hounsfield units and calculated attenuation coefficients of the material were shown to also be similar to PMMA. Total print time for the phantom was approximately 5 days. Initial scans of the phantom have been performed with Y-90 bremsstrahlung SPECT/CT, Y-90 PET/CT and Tc-99m SPECT/CT. The CT component of these images compared well with the original anatomical reference, and measurements of volume agreed to within 9 %. Quantitative analysis of the phantom was performed using all three imaging techniques. Lesion and normal liver absorbed doses were calculated from the quantitative images in three dimensions using the local deposition method. CONCLUSIONS 3D printing is a flexible and cost-efficient technology for manufacture of anthropomorphic phantom. Application of such phantoms will enable quantitative imaging and dosimetry methodologies to be evaluated, which with optimisation could help improve outcome for patients.
Collapse
|
34
|
Pre-clinical quantitative imaging and mouse-specific dosimetry for 111In-labelled radiotracers. EJNMMI Res 2016; 6:85. [PMID: 27885618 PMCID: PMC5122527 DOI: 10.1186/s13550-016-0238-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 11/14/2016] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND Accurate quantification in molecular imaging is essential to improve the assessment of novel drugs and compare the radiobiological effects of therapeutic agents prior to in-human studies. The aim of this study was to investigate the challenges and feasibility of pre-clinical quantitative imaging and mouse-specific dosimetry of 111In-labelled radiotracers. Attenuation, scatter and partial volume effects were studied using phantom experiments, and an activity calibration curve was obtained for varying sphere sizes. Six SK-OV-3-tumour bearing mice were injected with 111In-labelled HER2-targeting monoclonal antibodies (mAbs) (range 5.58-8.52 MBq). Sequential SPECT imaging up to 197 h post-injection was performed using the Albira SPECT/PET/CT pre-clinical scanner. Mice were culled for quantitative analysis of biodistribution studies. The tumour activity, mass and percentage of injected activity per gram of tissue (%IA/g) were calculated at the final scan time point and compared to the values determined from the biodistribution data. Delivered 111In-labelled mAbs tumour absorbed doses were calculated using mouse-specific convolution dosimetry, and absorbed doses for 90Y-labelled mAbs were extrapolated under the assumptions of equivalent injected activities, biological half-lives and uptake distributions as for 111In. RESULTS For the sphere sizes investigated (volume 0.03-1.17 ml), the calibration factor varied by a factor of 3.7, whilst for the range of tumour masses in the mice (41-232 mg), the calibration factor changed by a factor of 2.5. Comparisons between the mice imaging and the biodistribution results showed a statistically significant correlation for the tumour activity (r = 0.999, P < 0.0001) and the tumour mass calculations (r = 0.977, P = 0.0008), whilst no correlation was found for the %IA/g (r = 0.521, P = 0.29). Median tumour-absorbed doses per injected activity of 52 cGy/MBq (range 36-69 cGy/MBq) and 649 cGy/MBq (range 441-950 cGy/MBq) were delivered by 111In-labelled mAbs and extrapolated for 90Y-labelled mAbs, respectively. CONCLUSIONS This study demonstrates the need for multidisciplinary efforts to standardise imaging and dosimetry protocols in pre-clinical imaging. Accurate image quantification can improve the calculation of the activity, %IA/g and absorbed dose. Diagnostic imaging could be used to estimate the injected activities required for therapeutic studies, potentially reducing the number of animals used.
Collapse
|
35
|
Individualized 131I-mIBG therapy in the management of refractory and relapsed neuroblastoma. Nucl Med Commun 2016; 37:466-72. [PMID: 26813989 PMCID: PMC4819901 DOI: 10.1097/mnm.0000000000000470] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Revised: 11/18/2015] [Accepted: 12/07/2015] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Iodine-131-labelled meta-iodobenzylguanidine (I-mIBG) therapy is an established treatment modality for relapsed/refractory neuroblastoma, most frequently administered according to fixed or weight-based criteria. We evaluate response and toxicity following a dosimetry-based, individualized approach. MATERIALS AND METHODS A review of 44 treatments in 25 patients treated with I-mIBG therapy was performed. Patients received I-mIBG therapy following relapse (n=9), in refractory disease (n=12), or with surgically unresectable disease despite conventional treatment (n=4). Treatment schedule (including mIBG dose and number of administrations) was individualized according to the clinical status of the patient and dosimetry data from either a tracer study or previous administrations. Three-dimensional tumour dosimetry was also performed for eight patients. RESULTS The mean administered activity was 11089±7222 MBq and the mean whole-body dose for a single administration was 1.79±0.57 Gy. Tumour-absorbed doses varied considerably (3.70±3.37 mGy/MBq). CTCAE grade 3/4 neutropenia was documented following 82% treatments and grade 3/4 thrombocytopenia following 71% treatments. Further acute toxicity was found in 49% of patients. All acute toxicities resolved with appropriate therapy. The overall response rate was 58% (complete or partial response), with a further 29% of patients having stable disease. CONCLUSION A highly personalized approach combining patient-specific dosimetry and clinical judgement enables delivery of high activities that can be tolerated by patients, particularly with stem cell support. We report excellent response rates and acceptable toxicity following individualized I-mIBG therapy.
Collapse
|
36
|
A Phase 1, Open-Label Study of the Biodistribution, Pharmacokinetics, and Dosimetry of 223Ra-Dichloride in Patients with Hormone-Refractory Prostate Cancer and Skeletal Metastases. J Nucl Med 2015; 56:1304-9. [PMID: 26182965 DOI: 10.2967/jnumed.115.157123] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Accepted: 06/23/2015] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED The aim of this single-site, open-label clinical trial was to determine the biodistribution, pharmacokinetics, absorbed doses, and safety from 2 sequential weight-based administrations of (223)Ra-dichloride in patients with bone metastases due to castration-refractory prostate cancer. METHODS Six patients received 2 intravenous injections of (223)Ra-dichloride, 6 wk apart, at 100 kBq/kg of whole-body weight. The pharmacokinetics and biodistribution as a function of time were determined, and dosimetry was performed for a range of organs including bone surfaces, red marrow, kidneys, gut, and whole body using scintigraphic imaging; external counting; and blood, fecal, and urine collection. Safety was assessed from adverse events. RESULTS The injected activity cleared rapidly from blood, with 1.1% remaining at 24 h. The main route of excretion was via the gut, although no significant toxicity was reported. Most of the administered activity was taken up rapidly into bone (61% at 4 h). The range of absorbed doses delivered to the bone surfaces from α emissions was 2,331-13,118 mGy/MBq. The ranges of absorbed doses delivered to the red marrow were 177-994 and 1-5 mGy/MBq from activity on the bone surfaces and from activity in the blood, respectively. No activity-limiting toxicity was observed at these levels of administration. The absorbed doses from the second treatment were correlated significantly with the first for a combination of the whole body, bone surfaces, kidneys, and liver. CONCLUSION A wide range of interpatient absorbed doses was delivered to normal organs. Intrapatient absorbed doses were significantly correlated between the 2 administrations for any given patient. The lack of gastrointestinal toxicity is likely due to the low absorbed doses delivered to the gut wall from the gut contents. The lack of adverse myelotoxicity implies that the absorbed dose delivered from the circulating activity may be a more relevant guide to the potential for marrow toxicity than that due to activity on the bone surfaces.
Collapse
|
37
|
Development of patient-specific molecular imaging phantoms using a 3D printer. Med Phys 2014; 41:082502. [PMID: 25086556 DOI: 10.1118/1.4887854] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2014] [Revised: 06/16/2014] [Accepted: 06/26/2014] [Indexed: 02/11/2024] Open
Abstract
PURPOSE The aim of the study was to investigate rapid prototyping technology for the production of patient-specific, cost-effective liquid fillable phantoms directly from patient CT data. METHODS Liver, spleen, and kidney volumes were segmented from patient CT data. Each organ was converted to a shell and filling holes and leg supports were added using computer aided design software and prepared for printing. Additional fixtures were added to the liver to allow lesion inserts to be fixed within the structure. Phantoms were printed from an ultraviolet curable photopolymer using polyjet technology on an Objet EDEN 500V 3D printer. RESULTS The final print material is a clear solid acrylic plastic which is watertight, rigid, and sufficiently durable to withstand multiple assembly and scanning protocols. Initial scans of the phantoms have been performed with Tc-99m SPECT and F-18 PET/CT. CONCLUSIONS The organ geometry showed good correspondence with anatomical references. The methodology developed can be generally applied to other anatomical or geometrical phantoms for molecular imaging.
Collapse
|
38
|
|
39
|
Patient-specific dosimetry for intracavitary 32P-chromic phosphate colloid therapy of cystic brain tumours. Eur J Nucl Med Mol Imaging 2013; 40:1532-41. [PMID: 23740370 DOI: 10.1007/s00259-013-2451-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Accepted: 04/30/2013] [Indexed: 10/26/2022]
Abstract
PURPOSE (32)P-chromic phosphate colloid treatments of astrocytoma and craniopharyngioma cystic brain tumours in paediatric patients are conventionally based on a sphere model under the assumption of uniform uptake. The aims of this study were to determine the distribution of the absorbed dose delivered by (32)P on a patient-specific basis and to evaluate the accuracy with which this can be predicted from a pretherapy administration of (99m)Tc-Sn colloid. METHODS Three patients were treated with (32)P-chromic phosphate colloid following (99m)Tc-Sn colloid administrations. Convolution dosimetry was performed using pretherapy and posttherapy sequential SPECT imaging, and verified with EGSnrc Monte Carlo radiation transport simulations. Mean absorbed doses to the cyst wall and dose-volume histograms were also calculated and compared with those obtained by the sphere model approach. RESULTS Highly nonuniform uptake distributions of both the (99m)Tc and (32)P colloids were observed and characterized by dose-volume histograms to the cyst wall. Mean absorbed doses delivered to the cyst wall, obtained with the convolution method, were on average 21 % (SD 18 %) and 50 % (SD 30 %) lower than those predicted by the (99m)Tc distribution and the uniform assumption of the sphere model, respectively. CONCLUSION Absorbed doses delivered to the cyst wall by (32)P are more accurately predicted from image-based patient-specific convolution dosimetry than from simple sphere models. These results indicate the necessity to perform personalized treatment planning and verification for intracavitary irradiation of cystic brain tumours treated with radiocolloids. Patient-specific dosimetry can be used to guide the frequency and levels of repeated administrations and would facilitate data collection and comparison to support the multicentre trials necessary to progress this therapy.
Collapse
|
40
|
Dosimetry in 131I-mIBG therapy: moving toward personalized medicine. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2013; 57:161-70. [PMID: 23822991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Internal dosimetry was developed as a basis for 131I-mIBG treatment at an early stage and has continued to develop for over the last 20 years. Whole-body dosimetry was introduced to prevent hematological toxicity. It will be the basis for a forthcoming European multicentre trial, in which the activity of a second administration is determined according to the results calculated from the first. Lesion dosimetry has also been performed in a small number of centres. The major goal of dosimetry now is to establish dose-effect correlation studies, which will be the basis for individualized treatment planning. The aim of this paper is to analyse previously published studies and to consider the potential for improvement in order to obtain a stronger predictive power of dosimetry. The intrinsic radiobiological limits of dosimetry are also illustrated. Due to the development and dissemination of methods of internal dosimetry and radiobiology over the last two decades, and to the increasing availability of quantitative 124I PET imaging, dosimetry could provide in the near future a more systematic basis for standardization and individualization of mIBG therapy. This will however require a number of multicentre trials which are performed under good instrumental and scientific methodology.
Collapse
|
41
|
|
42
|
Abstract
Ra-223, an α-particle emitting bone-seeking radionuclide, has recently been used in clinical trials for osseous metastases of prostate cancer. We investigated the relationship between absorbed fraction-based red marrow dosimetry and cell level-dosimetry using a model that accounts for the expected localization of this agent relative to marrow cavity architecture. We show that cell level-based dosimetry is essential to understanding potential marrow toxicity. The GEANT4 software package was used to create simple spheres representing marrow cavities. Ra-223 was positioned on the trabecular bone surface or in the endosteal layer and simulated for decay, along with the descendants. The interior of the sphere was divided into cell-size voxels and the energy was collected in each voxel and interpreted as dose cell histograms. The average absorbed dose values and absorbed fractions were also calculated in order to compare those results with previously published values. The absorbed dose was predominantly deposited near the trabecular surface. The dose cell histogram results were used to plot the percentage of cells that received a potentially toxic absorbed dose (2 or 4 Gy) as a function of the average absorbed dose over the marrow cavity. The results show (1) a heterogeneous distribution of cellular absorbed dose, strongly dependent on the position of the cell within the marrow cavity; and (2) that increasing the average marrow cavity absorbed dose, or equivalently, increasing the administered activity resulted in only a small increase in potential marrow toxicity (i.e. the number of cells receiving more than 4 or 2 Gy), for a range of average marrow cavity absorbed doses from 1 to 20 Gy. The results from the trabecular model differ markedly from a standard absorbed fraction method while presenting comparable average dose values. These suggest that increasing the amount of radioactivity may not substantially increase the risk of toxicity, a result unavailable to the absorbed fraction method of dose calculation.
Collapse
|
43
|
Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study. Phys Med Biol 2011; 56:7273-86. [DOI: 10.1088/0031-9155/56/22/017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
44
|
Clinical dosimetry in the treatment of bone tumors: old and new agents. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2011; 55:198-204. [PMID: 21386790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Treatment of multisite, sclerotic bone metastases is successfully performed by radionuclide therapy. Pain palliation is the most common aim for the treatment. Two radiopharmaceuticals are currently approved by the European Medicines Agency ((153)Sm-EDTMP and (89)Sr-Cl₂) whilst other radiopharmaceuticals are at different stages of development, or are approved in some European countries ((186)Re-HEDP, (117)Snm-DTPA and (223)Ra-Cl₂). The tissues at risk for the treatment are bone marrow and normal bone. A review of the methods applied for dosimetry for these tissues and for tumours is performed, including the calculation of S values (the absorbed dose per decay) and optimal procedures on how to obtain biodistribution data for each radiopharmaceutical. The dosimetry data can be used to individualise and further improve the treatment for each patient. Dosimetry for radionuclide therapy of bone metastases is feasible and can be performed in a routine clinical practice.
Collapse
|
45
|
Clinical applications of dosimetry for mIBG therapy. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF... 2011; 55:116-125. [PMID: 21386786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Metaiodobenzylguanidine (mIBG), developed 30 years ago, is taken up by tumours expressing the noradrenaline transporter. Radiolabelled with I-123 or I-131, mIBG has become a gold standard for diagnostic imaging of pediatric and adult neuroendocrine cancer. Within a few years of its clinical introduction, I-131 mIBG was found to be an effective palliative treatment with minimal toxicity that in some cases could produce a complete response. The importance of internal dosimetry for I-131 mIBG therapy has been demonstrated by a number of studies showing that absorbed doses delivered to tumours and organs-at-risk from standard and weight-based activities can vary by an order of magnitude. However, significant correlations between the whole-body absorbed dose and myelotoxicity have been demonstrated and studies based on this relationship have enabled treatments to be tailored to the individual. Ongoing developments include patient-specific treatment planning based on tumour dosimetry and cocktails of radionuclides and radiosensitisers.
Collapse
|
46
|
Dosimetry of yttrium-labelled radiopharmaceuticals for internal therapy: 86Y or 90Y imaging? Eur J Nucl Med Mol Imaging 2011; 38 Suppl 1:S57-68. [DOI: 10.1007/s00259-011-1771-7] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2011] [Accepted: 02/22/2011] [Indexed: 12/31/2022]
|
47
|
|
48
|
Reply to: Can an undetectable value of TG and a negative neck ultrasound study be considered reliable methods to assess the completeness of thyroid ablation? Eur J Nucl Med Mol Imaging 2010. [DOI: 10.1007/s00259-010-1415-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
49
|
The effect of energy and source location on gamma camera intrinsic and extrinsic spatial resolution: an experimental and Monte Carlo study. Phys Med Biol 2010; 55:1735-51. [PMID: 20197600 DOI: 10.1088/0031-9155/55/6/013] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Quantification of nuclear medicine image data is a prerequisite for personalized absorbed dose calculations and quantitative biodistribution studies. The spatial response of a detector is a governing factor affecting the accuracy of image quantification, and the aim of this work was to model this impact. To simulate spatial response, a value for the intrinsic spatial resolution (R(intrinsic)) of the gamma camera is needed. R(intrinsic) for (99m)Tc was measured over the field of view (FOV) and an experimental setup was designed to measure R(intrinsic) for radioisotopes with higher photon energies. Monte Carlo (MC) simulations, using the codes SIMIND and GATE, were used to investigate the extrinsic effect of R(intrinsic) as a function of energy and its variation across the FOV. A method was developed to calculate energy-dependent blurring values for input to MC simulations, by separate consideration of the Compton scatter and photoelectric effect in the crystal and statistical variation in the signal. Inclusion of energy-specific blurring values in simulations showed excellent agreement with experimental measurements. The maximum pixel count rate can change by up to 18% when imaged at two different points in the FOV, and errors in the maximum pixel count rate of up to 11% were shown if a blurring value for (99m)Tc was used for simulations of (131)I. We demonstrate that the accuracy of MC simulations of gamma cameras can be significantly improved by accounting for the effect of energy on intrinsic spatial resolution.
Collapse
|
50
|
Whole-body dosimetry for individualized treatment planning of 131I-MIBG radionuclide therapy for neuroblastoma. J Nucl Med 2009; 50:1518-24. [PMID: 19713562 DOI: 10.2967/jnumed.109.064469] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED The aims of this study were to examine the relationship between whole-body absorbed dose and hematologic toxicity and to assess the most accurate method of delivering a prescribed whole-body absorbed dose in (131)I-metaiodobenzylguanidine ((131)I-MIBG) therapy for neuroblastoma. METHODS A total of 20 children (1-12 y), 5 adolescents (13-17 y), and 1 adult (20 y) with stage 3 or 4 neuroblastoma were treated to a prescribed whole-body absorbed dose, which in most cases was 2 Gy. Forty-eight administrations of (131)I-MIBG were given to the 26 patients, ranging in activity from 1,759 to 32,871 MBq. For 30 administrations, sufficient data were available to assess the effect of whole-body absorbed dose on hematologic toxicity. Comparisons were made between the accuracy with which a whole-body absorbed dose could be predicted using a pretherapy tracer study and the patient's most recent previous therapy. The whole-body absorbed dose that would have been delivered if the administered activity was fixed (7,400 MBq) or determined using a weight-based formula (444 MBq.kg(-1)) was also estimated. RESULTS The mean whole-body absorbed dose for patients with grade 4 Common Terminology Criteria for Adverse Events (CTCAE) neutropenia after therapy was significantly higher than for those with grade 1 CTCAE neutropenia (1.63 vs. 0.90 Gy; P = 0.05). There was no correlation between administered activity and hematologic toxicity. Absorbed whole-body doses predicted from previous therapies were within +/-10% for 70% of the cases. Fixed-activity administrations gave the largest range in whole-body absorbed dose (0.30-3.11 Gy). CONCLUSION The results indicate that even in a highly heterogeneous and heavily pretreated patient population, a whole-body absorbed dose can be prescribed accurately and is a more accurate predictor of hematologic toxicity than is administered activity. Therefore, a whole-body absorbed dose can be used to deliver accurate and reproducible (131)I-MIBG therapy on a patient-specific basis.
Collapse
|