1
|
Gut complement induced by the microbiota combats pathogens and spares commensals. Cell 2024; 187:897-913.e18. [PMID: 38280374 PMCID: PMC10922926 DOI: 10.1016/j.cell.2023.12.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 09/25/2023] [Accepted: 12/30/2023] [Indexed: 01/29/2024]
Abstract
Canonically, the complement system is known for its rapid response to remove microbes in the bloodstream. However, relatively little is known about a functioning complement system on intestinal mucosal surfaces. Herein, we report the local synthesis of complement component 3 (C3) in the gut, primarily by stromal cells. C3 is expressed upon commensal colonization and is regulated by the composition of the microbiota in healthy humans and mice, leading to an individual host's specific luminal C3 levels. The absence of membrane attack complex (MAC) components in the gut ensures that C3 deposition does not result in the lysis of commensals. Pathogen infection triggers the immune system to recruit neutrophils to the infection site for pathogen clearance. Basal C3 levels directly correlate with protection against enteric infection. Our study reveals the gut complement system as an innate immune mechanism acting as a vigilant sentinel that combats pathogens and spares commensals.
Collapse
|
2
|
Clinical and imaging features of drug-susceptible and multidrug-resistant TB in Korean adults. Int J Tuberc Lung Dis 2023; 27:487-489. [PMID: 37231602 DOI: 10.5588/ijtld.23.0017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023] Open
|
3
|
Microbiome induced complement synthesized in the gut protects against enteric infections. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.02.523770. [PMID: 36778396 PMCID: PMC9915568 DOI: 10.1101/2023.02.02.523770] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Canonically, complement is a serum-based host defense system that protects against systemic microbial invasion. Little is known about the production and function of complement components on mucosal surfaces. Here we show gut complement component 3 (C3), central to complement function, is regulated by the composition of the microbiota in healthy humans and mice, leading to host-specific gut C3 levels. Stromal cells in intestinal lymphoid follicles (LFs) are the predominant source of intestinal C3. During enteric infection with Citrobacter rodentium or enterohemorrhagic Escherichia coli, luminal C3 levels increase significantly and are required for protection. C. rodentium is remarkably more invasive to the gut epithelium of C3-deficient mice than of wild-type mice. In the gut, C3-mediated phagocytosis of C. rodentium functions to clear pathogens. Our study reveals that variations in gut microbiota determine individuals’ intestinal mucosal C3 levels, dominantly produced by LF stromal cells, which directly correlate with protection against enteric infection. Highlights Gut complement component 3 (C3) is induced by the microbiome in healthy humans and mice at a microbiota-specific level.Gut stromal cells located in intestinal lymphoid follicles are a major source of luminal C3 During enteric infections with Citrobacter rodentium or enterohemorrhagic Escherichia coli, gut luminal C3 levels increase and are required for protection. C. rodentium is significantly more invasive of the gut epithelium in C3-deficient mice when compared to WT mice. In the gut, C3-mediated opsonophagocytosis of C. rodentium functions to clear pathogens.
Collapse
|
4
|
Search for Subsolar-Mass Binaries in the First Half of Advanced LIGO's and Advanced Virgo's Third Observing Run. PHYSICAL REVIEW LETTERS 2022; 129:061104. [PMID: 36018635 DOI: 10.1103/physrevlett.129.061104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 03/18/2022] [Accepted: 06/07/2022] [Indexed: 06/15/2023]
Abstract
We report on a search for compact binary coalescences where at least one binary component has a mass between 0.2 M_{⊙} and 1.0 M_{⊙} in Advanced LIGO and Advanced Virgo data collected between 1 April 2019 1500 UTC and 1 October 2019 1500 UTC. We extend our previous analyses in two main ways: we include data from the Virgo detector and we allow for more unequal mass systems, with mass ratio q≥0.1. We do not report any gravitational-wave candidates. The most significant trigger has a false alarm rate of 0.14 yr^{-1}. This implies an upper limit on the merger rate of subsolar binaries in the range [220-24200] Gpc^{-3} yr^{-1}, depending on the chirp mass of the binary. We use this upper limit to derive astrophysical constraints on two phenomenological models that could produce subsolar-mass compact objects. One is an isotropic distribution of equal-mass primordial black holes. Using this model, we find that the fraction of dark matter in primordial black holes in the mass range 0.2 M_{⊙}<m_{PBH}<1.0 M_{⊙} is f_{PBH}≡Ω_{PBH}/Ω_{DM}≲6%. This improves existing constraints on primordial black hole abundance by a factor of ∼3. The other is a dissipative dark matter model, in which fermionic dark matter can collapse and form black holes. The upper limit on the fraction of dark matter black holes depends on the minimum mass of the black holes that can be formed: the most constraining result is obtained at M_{min}=1 M_{⊙}, where f_{DBH}≡Ω_{DBH}/Ω_{DM}≲0.003%. These are the first constraints placed on dissipative dark models by subsolar-mass analyses.
Collapse
|
5
|
Visit-to-visit changes in fasting blood sugar and the risk for cardiovascular disease and mortality in the Korean population: a nationwide population-based cohort study. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2021; 25:263-272. [PMID: 33506915 DOI: 10.26355/eurrev_202101_24392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The importance of continuous monitoring of fasting blood sugar (FBS) levels of diabetic patients has been established. MATERIALS AND METHODS An observational prospective study was conducted. Our analysis included 1,700,796 individuals from the nationwide South Korean National Health Insurance System cohort. FBS variability was measured by standard deviation (SD). RESULTS Kaplan-Meier curves demonstrated elevated disease probability in the higher FBS fluctuation group compared with the lower FBS fluctuation group. After adjusting for confounding variables, Cox proportional hazards analysis showed that the hazard ratios of 411 individuals in the highest quartile of SD variation of FBS were 1.77 (95% confidence interval 1.37-2.28, p<0.001) compared with the lowest quartile of SD variation of FBS. The impact of FBS fluctuation on the risk of cardiovascular diseases (CVDs), cerebrovascular diseases, CVD mortality and all-cause mortality in the highest quartiles of diabetic and non-diabetic individuals was statistically significant. CONCLUSIONS Visit-to-visit FBS variability has prognostic value for predicting micro- and macrovascular disease, cardiovascular mortality, and all-cause mortality.
Collapse
|
6
|
Constraints on Cosmic Strings Using Data from the Third Advanced LIGO-Virgo Observing Run. PHYSICAL REVIEW LETTERS 2021; 126:241102. [PMID: 34213926 DOI: 10.1103/physrevd.97.102002] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 05/23/2021] [Indexed: 05/21/2023]
Abstract
We search for gravitational-wave signals produced by cosmic strings in the Advanced LIGO and Virgo full O3 dataset. Search results are presented for gravitational waves produced by cosmic string loop features such as cusps, kinks, and, for the first time, kink-kink collisions. A template-based search for short-duration transient signals does not yield a detection. We also use the stochastic gravitational-wave background energy density upper limits derived from the O3 data to constrain the cosmic string tension Gμ as a function of the number of kinks, or the number of cusps, for two cosmic string loop distribution models. Additionally, we develop and test a third model that interpolates between these two models. Our results improve upon the previous LIGO-Virgo constraints on Gμ by 1 to 2 orders of magnitude depending on the model that is tested. In particular, for the one-loop distribution model, we set the most competitive constraints to date: Gμ≲4×10^{-15}. In the case of cosmic strings formed at the end of inflation in the context of grand unified theories, these results challenge simple inflationary models.
Collapse
|
7
|
Constraints on Cosmic Strings Using Data from the Third Advanced LIGO-Virgo Observing Run. PHYSICAL REVIEW LETTERS 2021; 126:241102. [PMID: 34213926 DOI: 10.1103/physrevlett.126.241102] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Revised: 03/31/2021] [Accepted: 05/23/2021] [Indexed: 06/13/2023]
Abstract
We search for gravitational-wave signals produced by cosmic strings in the Advanced LIGO and Virgo full O3 dataset. Search results are presented for gravitational waves produced by cosmic string loop features such as cusps, kinks, and, for the first time, kink-kink collisions. A template-based search for short-duration transient signals does not yield a detection. We also use the stochastic gravitational-wave background energy density upper limits derived from the O3 data to constrain the cosmic string tension Gμ as a function of the number of kinks, or the number of cusps, for two cosmic string loop distribution models. Additionally, we develop and test a third model that interpolates between these two models. Our results improve upon the previous LIGO-Virgo constraints on Gμ by 1 to 2 orders of magnitude depending on the model that is tested. In particular, for the one-loop distribution model, we set the most competitive constraints to date: Gμ≲4×10^{-15}. In the case of cosmic strings formed at the end of inflation in the context of grand unified theories, these results challenge simple inflationary models.
Collapse
|
8
|
GW190521: A Binary Black Hole Merger with a Total Mass of 150 M_{⊙}. PHYSICAL REVIEW LETTERS 2020; 125:101102. [PMID: 32955328 DOI: 10.1103/physrevlett.125.101102] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Revised: 06/19/2020] [Accepted: 07/09/2020] [Indexed: 06/08/2023]
Abstract
On May 21, 2019 at 03:02:29 UTC Advanced LIGO and Advanced Virgo observed a short duration gravitational-wave signal, GW190521, with a three-detector network signal-to-noise ratio of 14.7, and an estimated false-alarm rate of 1 in 4900 yr using a search sensitive to generic transients. If GW190521 is from a quasicircular binary inspiral, then the detected signal is consistent with the merger of two black holes with masses of 85_{-14}^{+21} M_{⊙} and 66_{-18}^{+17} M_{⊙} (90% credible intervals). We infer that the primary black hole mass lies within the gap produced by (pulsational) pair-instability supernova processes, with only a 0.32% probability of being below 65 M_{⊙}. We calculate the mass of the remnant to be 142_{-16}^{+28} M_{⊙}, which can be considered an intermediate mass black hole (IMBH). The luminosity distance of the source is 5.3_{-2.6}^{+2.4} Gpc, corresponding to a redshift of 0.82_{-0.34}^{+0.28}. The inferred rate of mergers similar to GW190521 is 0.13_{-0.11}^{+0.30} Gpc^{-3} yr^{-1}.
Collapse
|
9
|
CD8 + T Cells Require ITK-Mediated TCR Signaling for Migration to the Intestine. Immunohorizons 2020; 4:57-71. [PMID: 32034085 PMCID: PMC7521019 DOI: 10.4049/immunohorizons.1900093] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 01/12/2020] [Indexed: 12/21/2022] Open
Abstract
The Tec kinase IL-2–inducible T cell kinase (ITK) regulates the expression of TCR-induced genes. Itk−/− T cell responses are impaired but not absent. ITK inhibition prevented colitis disease progression and impaired T cell migration to the colon in mice. To examine the function of ITK in T cell migration to the intestine, we examined the number of gut T cells in Itk−/− mice and then evaluated their expression of gut-homing receptors. Combined with in vitro murine T cell stimulation and in vivo migration assay using congenic B6 mice, we demonstrated an essential role for ITK in T cell migration to the intestine in mice. Reconstitution of Itk−/− mouse CD8+ T cells with IFN regulatory factor 4 restored gut-homing properties, providing mechanistic insight into the function of ITK-mediated signaling in CD8+ T cell migration to the intestinal mucosa in mice.
Collapse
|
10
|
Search for Subsolar Mass Ultracompact Binaries in Advanced LIGO's Second Observing Run. PHYSICAL REVIEW LETTERS 2019; 123:161102. [PMID: 31702344 DOI: 10.1103/physrevlett.123.161102] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2019] [Indexed: 06/10/2023]
Abstract
We present a search for subsolar mass ultracompact objects in data obtained during Advanced LIGO's second observing run. In contrast to a previous search of Advanced LIGO data from the first observing run, this search includes the effects of component spin on the gravitational waveform. We identify no viable gravitational-wave candidates consistent with subsolar mass ultracompact binaries with at least one component between 0.2 M_{⊙}-1.0 M_{⊙}. We use the null result to constrain the binary merger rate of (0.2 M_{⊙}, 0.2 M_{⊙}) binaries to be less than 3.7×10^{5} Gpc^{-3} yr^{-1} and the binary merger rate of (1.0 M_{⊙}, 1.0 M_{⊙}) binaries to be less than 5.2×10^{3} Gpc^{-3} yr^{-1}. Subsolar mass ultracompact objects are not expected to form via known stellar evolution channels, though it has been suggested that primordial density fluctuations or particle dark matter with cooling mechanisms and/or nuclear interactions could form black holes with subsolar masses. Assuming a particular primordial black hole (PBH) formation model, we constrain a population of merging 0.2 M_{⊙} black holes to account for less than 16% of the dark matter density and a population of merging 1.0 M_{⊙} black holes to account for less than 2% of the dark matter density. We discuss how constraints on the merger rate and dark matter fraction may be extended to arbitrary black hole population models that predict subsolar mass binaries.
Collapse
|
11
|
Tests of General Relativity with GW170817. PHYSICAL REVIEW LETTERS 2019; 123:011102. [PMID: 31386391 DOI: 10.1103/physrevlett.123.011102] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 03/21/2019] [Indexed: 06/10/2023]
Abstract
The recent discovery by Advanced LIGO and Advanced Virgo of a gravitational wave signal from a binary neutron star inspiral has enabled tests of general relativity (GR) with this new type of source. This source, for the first time, permits tests of strong-field dynamics of compact binaries in the presence of matter. In this Letter, we place constraints on the dipole radiation and possible deviations from GR in the post-Newtonian coefficients that govern the inspiral regime. Bounds on modified dispersion of gravitational waves are obtained; in combination with information from the observed electromagnetic counterpart we can also constrain effects due to large extra dimensions. Finally, the polarization content of the gravitational wave signal is studied. The results of all tests performed here show good agreement with GR.
Collapse
|
12
|
Are patients with mild to moderate renal impairment on metformin or other oral anti-hyperglycaemic agents at increased risk of contrast-induced nephropathy and metabolic acidosis after radiocontrast exposure? Clin Radiol 2019; 74:651.e1-651.e6. [PMID: 31202566 DOI: 10.1016/j.crad.2019.05.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Accepted: 05/16/2019] [Indexed: 10/26/2022]
Abstract
AIM To investigate whether the use of metformin during computed tomography (CT) with radiocontrast agents increases the risk of contrast-induced nephropathy (CIN) and metabolic acidosis after CT in type 2 diabetes patients with mild to moderate renal failure. MATERIALS AND METHODS Patient records from January 2015 to December 2017 were reviewed retrospectively. A total of 374 patients were included in the final analysis. Of them, 157 patients received metformin, and 217 patients were taking other oral hypoglycaemic agents (OHAs) during radiocontrast administration. RESULTS No significant difference in CIN incidence was observed between the metformin use group and the other OHAs group (p=0.085). Metabolic acidosis after CT was seen in 91 (58%) patients who used metformin and 141 (65%) patients who were taking other OHAs. There was no relationship between metabolic acidosis after CT and the use of metformin (p=0.195). Metabolic acidosis after radiocontrast agent exposure was associated with malignant disease, low serum albumin level, and low serum total CO2 level at baseline. CONCLUSION These data show that other factors, but not metformin use, are associated with metabolic acidosis after radiocontrast agent exposure in patients with reduced renal function. These data support current recommendations that there is no need to discontinue metformin before CT using radiocontrast agents in patients with mild to moderate renal failure.
Collapse
|
13
|
The Tec kinase ITK is essential for ILC2 survival and epithelial integrity in the intestine. Nat Commun 2019; 10:784. [PMID: 30770814 PMCID: PMC6377622 DOI: 10.1038/s41467-019-08699-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 01/22/2019] [Indexed: 02/06/2023] Open
Abstract
Innate lymphoid cells (ILC) are lymphocytes that lack an antigen-specific receptor and are preferentially localized in non-lymphoid tissues, such as mucosal barriers. In these locations ILC respond to tissue perturbations by producing factors that promote tissue repair and improve barrier integrity. We show that mice lacking the Tec kinase ITK have impaired intestinal tissue integrity, and a reduced ability to restore homeostasis after tissue damage. This defect is associated with a substantial loss of Type 2 ILC (ILC2) in the intestinal lamina propria. Adoptive transfer of bone marrow ILC2 precursors confirms a cell-intrinsic role for ITK. Intestinal ILC2 numbers in Itk-/- mice are restored by the administration of IL-2 complexes, also leading to improved intestinal tissue damage repair. Reduced Bcl-2 expression in intestinal Itk-/- ILC2 is also restored to WT levels after IL-2 complex treatment, indicating a tissue-specific role for ITK in ILC2 survival in the intestine.
Collapse
|
14
|
Constraining the p-Mode-g-Mode Tidal Instability with GW170817. PHYSICAL REVIEW LETTERS 2019; 122:061104. [PMID: 30822067 DOI: 10.1103/physrevlett.122.061104] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 10/30/2018] [Indexed: 06/09/2023]
Abstract
We analyze the impact of a proposed tidal instability coupling p modes and g modes within neutron stars on GW170817. This nonresonant instability transfers energy from the orbit of the binary to internal modes of the stars, accelerating the gravitational-wave driven inspiral. We model the impact of this instability on the phasing of the gravitational wave signal using three parameters per star: an overall amplitude, a saturation frequency, and a spectral index. Incorporating these additional parameters, we compute the Bayes factor (lnB_{!pg}^{pg}) comparing our p-g model to a standard one. We find that the observed signal is consistent with waveform models that neglect p-g effects, with lnB_{!pg}^{pg}=0.03_{-0.58}^{+0.70} (maximum a posteriori and 90% credible region). By injecting simulated signals that do not include p-g effects and recovering them with the p-g model, we show that there is a ≃50% probability of obtaining similar lnB_{!pg}^{pg} even when p-g effects are absent. We find that the p-g amplitude for 1.4 M_{⊙} neutron stars is constrained to less than a few tenths of the theoretical maximum, with maxima a posteriori near one-tenth this maximum and p-g saturation frequency ∼70 Hz. This suggests that there are less than a few hundred excited modes, assuming they all saturate by wave breaking. For comparison, theoretical upper bounds suggest ≲10^{3} modes saturate by wave breaking. Thus, the measured constraints only rule out extreme values of the p-g parameters. They also imply that the instability dissipates ≲10^{51} erg over the entire inspiral, i.e., less than a few percent of the energy radiated as gravitational waves.
Collapse
|
15
|
Search for Subsolar-Mass Ultracompact Binaries in Advanced LIGO's First Observing Run. PHYSICAL REVIEW LETTERS 2018; 121:231103. [PMID: 30576173 DOI: 10.1103/physrevlett.121.231103] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Indexed: 05/21/2023]
Abstract
We present the first Advanced LIGO and Advanced Virgo search for ultracompact binary systems with component masses between 0.2 M_{⊙}-1.0 M_{⊙} using data taken between September 12, 2015 and January 19, 2016. We find no viable gravitational wave candidates. Our null result constrains the coalescence rate of monochromatic (delta function) distributions of nonspinning (0.2 M_{⊙}, 0.2 M_{⊙}) ultracompact binaries to be less than 1.0×10^{6} Gpc^{-3} yr^{-1} and the coalescence rate of a similar distribution of (1.0 M_{⊙}, 1.0 M_{⊙}) ultracompact binaries to be less than 1.9×10^{4} Gpc^{-3} yr^{-1} (at 90% confidence). Neither black holes nor neutron stars are expected to form below ∼1 M_{⊙} through conventional stellar evolution, though it has been proposed that similarly low mass black holes could be formed primordially through density fluctuations in the early Universe and contribute to the dark matter density. The interpretation of our constraints in the primordial black hole dark matter paradigm is highly model dependent; however, under a particular primordial black hole binary formation scenario we constrain monochromatic primordial black hole populations of 0.2 M_{⊙} to be less than 33% of the total dark matter density and monochromatic populations of 1.0 M_{⊙} to be less than 5% of the dark matter density. The latter strengthens the presently placed bounds from microlensing surveys of massive compact halo objects (MACHOs) provided by the MACHO and EROS Collaborations.
Collapse
|
16
|
GW170817: Measurements of Neutron Star Radii and Equation of State. PHYSICAL REVIEW LETTERS 2018; 121:161101. [PMID: 30387654 DOI: 10.1103/physrevlett.121.161101] [Citation(s) in RCA: 186] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 07/25/2018] [Indexed: 06/08/2023]
Abstract
On 17 August 2017, the LIGO and Virgo observatories made the first direct detection of gravitational waves from the coalescence of a neutron star binary system. The detection of this gravitational-wave signal, GW170817, offers a novel opportunity to directly probe the properties of matter at the extreme conditions found in the interior of these stars. The initial, minimal-assumption analysis of the LIGO and Virgo data placed constraints on the tidal effects of the coalescing bodies, which were then translated to constraints on neutron star radii. Here, we expand upon previous analyses by working under the hypothesis that both bodies were neutron stars that are described by the same equation of state and have spins within the range observed in Galactic binary neutron stars. Our analysis employs two methods: the use of equation-of-state-insensitive relations between various macroscopic properties of the neutron stars and the use of an efficient parametrization of the defining function p(ρ) of the equation of state itself. From the LIGO and Virgo data alone and the first method, we measure the two neutron star radii as R_{1}=10.8_{-1.7}^{+2.0} km for the heavier star and R_{2}=10.7_{-1.5}^{+2.1} km for the lighter star at the 90% credible level. If we additionally require that the equation of state supports neutron stars with masses larger than 1.97 M_{⊙} as required from electromagnetic observations and employ the equation-of-state parametrization, we further constrain R_{1}=11.9_{-1.4}^{+1.4} km and R_{2}=11.9_{-1.4}^{+1.4} km at the 90% credible level. Finally, we obtain constraints on p(ρ) at supranuclear densities, with pressure at twice nuclear saturation density measured at 3.5_{-1.7}^{+2.7}×10^{34} dyn cm^{-2} at the 90% level.
Collapse
|
17
|
Search for Tensor, Vector, and Scalar Polarizations in the Stochastic Gravitational-Wave Background. PHYSICAL REVIEW LETTERS 2018; 120:201102. [PMID: 29864331 DOI: 10.1103/physrevlett.120.201102] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Revised: 03/30/2018] [Indexed: 06/08/2023]
Abstract
The detection of gravitational waves with Advanced LIGO and Advanced Virgo has enabled novel tests of general relativity, including direct study of the polarization of gravitational waves. While general relativity allows for only two tensor gravitational-wave polarizations, general metric theories can additionally predict two vector and two scalar polarizations. The polarization of gravitational waves is encoded in the spectral shape of the stochastic gravitational-wave background, formed by the superposition of cosmological and individually unresolved astrophysical sources. Using data recorded by Advanced LIGO during its first observing run, we search for a stochastic background of generically polarized gravitational waves. We find no evidence for a background of any polarization, and place the first direct bounds on the contributions of vector and scalar polarizations to the stochastic background. Under log-uniform priors for the energy in each polarization, we limit the energy densities of tensor, vector, and scalar modes at 95% credibility to Ω_{0}^{T}<5.58×10^{-8}, Ω_{0}^{V}<6.35×10^{-8}, and Ω_{0}^{S}<1.08×10^{-7} at a reference frequency f_{0}=25 Hz.
Collapse
|
18
|
GW170817: Implications for the Stochastic Gravitational-Wave Background from Compact Binary Coalescences. PHYSICAL REVIEW LETTERS 2018; 120:091101. [PMID: 29547330 DOI: 10.1103/physrevlett.120.091101] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2017] [Revised: 01/16/2018] [Indexed: 06/08/2023]
Abstract
The LIGO Scientific and Virgo Collaborations have announced the event GW170817, the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star component will add to the contribution from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude Ω_{GW}(f=25 Hz)=1.8_{-1.3}^{+2.7}×10^{-9} with 90% confidence, compared with Ω_{GW}(f=25 Hz)=1.1_{-0.7}^{+1.2}×10^{-9} from binary black holes alone. Assuming the most probable rate for compact binary mergers, we find that the total background may be detectable with a signal-to-noise-ratio of 3 after 40 months of total observation time, based on the expected timeline for Advanced LIGO and Virgo to reach their design sensitivity.
Collapse
|
19
|
First Search for Nontensorial Gravitational Waves from Known Pulsars. PHYSICAL REVIEW LETTERS 2018; 120:031104. [PMID: 29400511 DOI: 10.1103/physrevlett.120.031104] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 11/16/2017] [Indexed: 06/07/2023]
Abstract
We present results from the first directed search for nontensorial gravitational waves. While general relativity allows for tensorial (plus and cross) modes only, a generic metric theory may, in principle, predict waves with up to six different polarizations. This analysis is sensitive to continuous signals of scalar, vector, or tensor polarizations, and does not rely on any specific theory of gravity. After searching data from the first observation run of the advanced LIGO detectors for signals at twice the rotational frequency of 200 known pulsars, we find no evidence of gravitational waves of any polarization. We report the first upper limits for scalar and vector strains, finding values comparable in magnitude to previously published limits for tensor strain. Our results may be translated into constraints on specific alternative theories of gravity.
Collapse
|
20
|
GW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral. PHYSICAL REVIEW LETTERS 2017; 119:161101. [PMID: 29099225 DOI: 10.1103/physrevlett.119.161101] [Citation(s) in RCA: 848] [Impact Index Per Article: 121.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Indexed: 05/21/2023]
Abstract
On August 17, 2017 at 12∶41:04 UTC the Advanced LIGO and Advanced Virgo gravitational-wave detectors made their first observation of a binary neutron star inspiral. The signal, GW170817, was detected with a combined signal-to-noise ratio of 32.4 and a false-alarm-rate estimate of less than one per 8.0×10^{4} years. We infer the component masses of the binary to be between 0.86 and 2.26 M_{⊙}, in agreement with masses of known neutron stars. Restricting the component spins to the range inferred in binary neutron stars, we find the component masses to be in the range 1.17-1.60 M_{⊙}, with the total mass of the system 2.74_{-0.01}^{+0.04}M_{⊙}. The source was localized within a sky region of 28 deg^{2} (90% probability) and had a luminosity distance of 40_{-14}^{+8} Mpc, the closest and most precisely localized gravitational-wave signal yet. The association with the γ-ray burst GRB 170817A, detected by Fermi-GBM 1.7 s after the coalescence, corroborates the hypothesis of a neutron star merger and provides the first direct evidence of a link between these mergers and short γ-ray bursts. Subsequent identification of transient counterparts across the electromagnetic spectrum in the same location further supports the interpretation of this event as a neutron star merger. This unprecedented joint gravitational and electromagnetic observation provides insight into astrophysics, dense matter, gravitation, and cosmology.
Collapse
|
21
|
GW170814: A Three-Detector Observation of Gravitational Waves from a Binary Black Hole Coalescence. PHYSICAL REVIEW LETTERS 2017; 119:141101. [PMID: 29053306 DOI: 10.1103/physrevlett.119.141101] [Citation(s) in RCA: 163] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Indexed: 05/21/2023]
Abstract
On August 14, 2017 at 10∶30:43 UTC, the Advanced Virgo detector and the two Advanced LIGO detectors coherently observed a transient gravitational-wave signal produced by the coalescence of two stellar mass black holes, with a false-alarm rate of ≲1 in 27 000 years. The signal was observed with a three-detector network matched-filter signal-to-noise ratio of 18. The inferred masses of the initial black holes are 30.5_{-3.0}^{+5.7}M_{⊙} and 25.3_{-4.2}^{+2.8}M_{⊙} (at the 90% credible level). The luminosity distance of the source is 540_{-210}^{+130} Mpc, corresponding to a redshift of z=0.11_{-0.04}^{+0.03}. A network of three detectors improves the sky localization of the source, reducing the area of the 90% credible region from 1160 deg^{2} using only the two LIGO detectors to 60 deg^{2} using all three detectors. For the first time, we can test the nature of gravitational-wave polarizations from the antenna response of the LIGO-Virgo network, thus enabling a new class of phenomenological tests of gravity.
Collapse
|
22
|
GW170104: Observation of a 50-Solar-Mass Binary Black Hole Coalescence at Redshift 0.2. PHYSICAL REVIEW LETTERS 2017; 118:221101. [PMID: 28621973 DOI: 10.1103/physrevlett.118.221101] [Citation(s) in RCA: 220] [Impact Index Per Article: 31.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Indexed: 05/21/2023]
Abstract
We describe the observation of GW170104, a gravitational-wave signal produced by the coalescence of a pair of stellar-mass black holes. The signal was measured on January 4, 2017 at 10∶11:58.6 UTC by the twin advanced detectors of the Laser Interferometer Gravitational-Wave Observatory during their second observing run, with a network signal-to-noise ratio of 13 and a false alarm rate less than 1 in 70 000 years. The inferred component black hole masses are 31.2_{-6.0}^{+8.4}M_{⊙} and 19.4_{-5.9}^{+5.3}M_{⊙} (at the 90% credible level). The black hole spins are best constrained through measurement of the effective inspiral spin parameter, a mass-weighted combination of the spin components perpendicular to the orbital plane, χ_{eff}=-0.12_{-0.30}^{+0.21}. This result implies that spin configurations with both component spins positively aligned with the orbital angular momentum are disfavored. The source luminosity distance is 880_{-390}^{+450} Mpc corresponding to a redshift of z=0.18_{-0.07}^{+0.08}. We constrain the magnitude of modifications to the gravitational-wave dispersion relation and perform null tests of general relativity. Assuming that gravitons are dispersed in vacuum like massive particles, we bound the graviton mass to m_{g}≤7.7×10^{-23} eV/c^{2}. In all cases, we find that GW170104 is consistent with general relativity.
Collapse
|
23
|
Upper Limits on the Stochastic Gravitational-Wave Background from Advanced LIGO's First Observing Run. PHYSICAL REVIEW LETTERS 2017; 118:121101. [PMID: 28388180 DOI: 10.1103/physrevlett.118.121101] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Indexed: 05/14/2023]
Abstract
A wide variety of astrophysical and cosmological sources are expected to contribute to a stochastic gravitational-wave background. Following the observations of GW150914 and GW151226, the rate and mass of coalescing binary black holes appear to be greater than many previous expectations. As a result, the stochastic background from unresolved compact binary coalescences is expected to be particularly loud. We perform a search for the isotropic stochastic gravitational-wave background using data from Advanced Laser Interferometer Gravitational Wave Observatory's (aLIGO) first observing run. The data display no evidence of a stochastic gravitational-wave signal. We constrain the dimensionless energy density of gravitational waves to be Ω_{0}<1.7×10^{-7} with 95% confidence, assuming a flat energy density spectrum in the most sensitive part of the LIGO band (20-86 Hz). This is a factor of ∼33 times more sensitive than previous measurements. We also constrain arbitrary power-law spectra. Finally, we investigate the implications of this search for the background of binary black holes using an astrophysical model for the background.
Collapse
|
24
|
Directional Limits on Persistent Gravitational Waves from Advanced LIGO's First Observing Run. PHYSICAL REVIEW LETTERS 2017; 118:121102. [PMID: 28388200 DOI: 10.1103/physrevlett.118.121102] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Indexed: 06/07/2023]
Abstract
We employ gravitational-wave radiometry to map the stochastic gravitational wave background expected from a variety of contributing mechanisms and test the assumption of isotropy using data from the Advanced Laser Interferometer Gravitational Wave Observatory's (aLIGO) first observing run. We also search for persistent gravitational waves from point sources with only minimal assumptions over the 20-1726 Hz frequency band. Finding no evidence of gravitational waves from either point sources or a stochastic background, we set limits at 90% confidence. For broadband point sources, we report upper limits on the gravitational wave energy flux per unit frequency in the range F_{α,Θ}(f)<(0.1-56)×10^{-8} erg cm^{-2} s^{-1} Hz^{-1}(f/25 Hz)^{α-1} depending on the sky location Θ and the spectral power index α. For extended sources, we report upper limits on the fractional gravitational wave energy density required to close the Universe of Ω(f,Θ)<(0.39-7.6)×10^{-8} sr^{-1}(f/25 Hz)^{α} depending on Θ and α. Directed searches for narrowband gravitational waves from astrophysically interesting objects (Scorpius X-1, Supernova 1987 A, and the Galactic Center) yield median frequency-dependent limits on strain amplitude of h_{0}<(6.7,5.5, and 7.0)×10^{-25}, respectively, at the most sensitive detector frequencies between 130-175 Hz. This represents a mean improvement of a factor of 2 across the band compared to previous searches of this kind for these sky locations, considering the different quantities of strain constrained in each case.
Collapse
|
25
|
Abstract
OBJECTIVES We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. METHODS We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. RESULTS The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p < 0.05, one-way analysis of variance). The probabilities of a surgeon obtaining a 10 mm surgical margin with a 3 mm tolerance were 90.2% in AR-assisted resections, and 70.7% in conventional resections. CONCLUSION We demonstrated that the accuracy of tumour resection was satisfactory with the help of the AR navigation system, with the tumour shown as a virtual template. In addition, this concept made the navigation system simple and available without additional cost or time.Cite this article: H. S. Cho, Y. K. Park, S. Gupta, C. Yoon, I. Han, H-S. Kim, H. Choi, J. Hong. Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137-143.
Collapse
|
26
|
Characterization of transient noise in Advanced LIGO relevant to gravitational wave signal GW150914. CLASSICAL AND QUANTUM GRAVITY 2016; 33:134001. [PMID: 32908328 PMCID: PMC7477940 DOI: 10.1088/0264-9381/33/13/134001] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
On September 14, 2015, a gravitational wave signal from a coalescing black hole binary system was observed by the Advanced LIGO detectors. This paper describes the transient noise backgrounds used to determine the significance of the event (designated GW150914) and presents the results of investigations into potential correlated or uncorrelated sources of transient noise in the detectors around the time of the event. The detectors were operating nominally at the time of GW150914. We have ruled out environmental influences and non-Gaussian instrument noise at either LIGO detector as the cause of the observed gravitational wave signal.
Collapse
|
27
|
Abstract
A 10-year-old female Eurasian river otter ( Lutra lutra) died after prolonged anorexia and weight loss in the Seoul Grand Park Zoo, Seoul, Republic of Korea. On necropsy, the liver was found to be swollen and friable with 1 lobe enlarged and necrotic. The other organs showed no significant alterations except for mild atrophy of the right kidney. Microscopically, there was multifocal hepatic necrosis. The hepatocytes around the necrotic areas were swollen and contained large basophilic intranuclear inclusions. Periportal infiltration by plasma cells and lymphocytes was also evident. Transmission electron microscopy revealed characteristic hexagonal virus particles sized approximately 70 nm in diameter in the nuclei of the hepatocytes, which were consistent with an adenovirus. Polymerase chain reaction of the formalin-fixed, paraffin-embedded liver sections was used to determine whether the virus was either the canine adenovirus type 1 (CAV-1), canine adenovirus type 2 (CAV-2), or some other viral agent. The results of these tests showed that the virus was CAV-1. To our knowledge, this is the first report on a CAV-1 infection in an otter.
Collapse
|
28
|
GW151226: Observation of Gravitational Waves from a 22-Solar-Mass Binary Black Hole Coalescence. PHYSICAL REVIEW LETTERS 2016; 116:241103. [PMID: 27367379 DOI: 10.1103/physrevlett.116.241103] [Citation(s) in RCA: 282] [Impact Index Per Article: 35.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Indexed: 05/21/2023]
Abstract
We report the observation of a gravitational-wave signal produced by the coalescence of two stellar-mass black holes. The signal, GW151226, was observed by the twin detectors of the Laser Interferometer Gravitational-Wave Observatory (LIGO) on December 26, 2015 at 03:38:53 UTC. The signal was initially identified within 70 s by an online matched-filter search targeting binary coalescences. Subsequent off-line analyses recovered GW151226 with a network signal-to-noise ratio of 13 and a significance greater than 5σ. The signal persisted in the LIGO frequency band for approximately 1 s, increasing in frequency and amplitude over about 55 cycles from 35 to 450 Hz, and reached a peak gravitational strain of 3.4_{-0.9}^{+0.7}×10^{-22}. The inferred source-frame initial black hole masses are 14.2_{-3.7}^{+8.3}M_{⊙} and 7.5_{-2.3}^{+2.3}M_{⊙}, and the final black hole mass is 20.8_{-1.7}^{+6.1}M_{⊙}. We find that at least one of the component black holes has spin greater than 0.2. This source is located at a luminosity distance of 440_{-190}^{+180} Mpc corresponding to a redshift of 0.09_{-0.04}^{+0.03}. All uncertainties define a 90% credible interval. This second gravitational-wave observation provides improved constraints on stellar populations and on deviations from general relativity.
Collapse
|
29
|
Properties of the Binary Black Hole Merger GW150914. PHYSICAL REVIEW LETTERS 2016; 116:241102. [PMID: 27367378 DOI: 10.1103/physrevlett.116.241102] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2016] [Indexed: 05/21/2023]
Abstract
On September 14, 2015, the Laser Interferometer Gravitational-Wave Observatory (LIGO) detected a gravitational-wave transient (GW150914); we characterize the properties of the source and its parameters. The data around the time of the event were analyzed coherently across the LIGO network using a suite of accurate waveform models that describe gravitational waves from a compact binary system in general relativity. GW150914 was produced by a nearly equal mass binary black hole of masses 36_{-4}^{+5}M_{⊙} and 29_{-4}^{+4}M_{⊙}; for each parameter we report the median value and the range of the 90% credible interval. The dimensionless spin magnitude of the more massive black hole is bound to be <0.7 (at 90% probability). The luminosity distance to the source is 410_{-180}^{+160} Mpc, corresponding to a redshift 0.09_{-0.04}^{+0.03} assuming standard cosmology. The source location is constrained to an annulus section of 610 deg^{2}, primarily in the southern hemisphere. The binary merges into a black hole of mass 62_{-4}^{+4}M_{⊙} and spin 0.67_{-0.07}^{+0.05}. This black hole is significantly more massive than any other inferred from electromagnetic observations in the stellar-mass regime.
Collapse
|
30
|
GW150914: First results from the search for binary black hole coalescence with Advanced LIGO. PHYSICAL REVIEW. D. (2016) 2016; 93:122003. [PMID: 32818163 PMCID: PMC7430253 DOI: 10.1103/physrevd.93.122003] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
On September 14, 2015 at 09:50:45 UTC the two detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO) simultaneously observed the binary black hole merger GW150914. We report the results of a matched-filter search using relativistic models of compact-object binaries that recovered GW150914 as the most significant event during the coincident observations between the two LIGO detectors from September 12 to October 20, 2015. GW150914 was observed with a matched filter signal-to-noise ratio of 24 and a false alarm rate estimated to be less than 1 event per 203000 years, equivalent to a significance greater than 5.1 σ.
Collapse
|
31
|
GW150914: First results from the search for binary black hole coalescence with Advanced LIGO. PHYSICAL REVIEW. D. (2016) 2016; 93:122003. [PMID: 32818163 DOI: 10.1103/physrevd.93.112004] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
On September 14, 2015 at 09:50:45 UTC the two detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO) simultaneously observed the binary black hole merger GW150914. We report the results of a matched-filter search using relativistic models of compact-object binaries that recovered GW150914 as the most significant event during the coincident observations between the two LIGO detectors from September 12 to October 20, 2015. GW150914 was observed with a matched filter signal-to-noise ratio of 24 and a false alarm rate estimated to be less than 1 event per 203000 years, equivalent to a significance greater than 5.1 σ.
Collapse
|
32
|
Abstract
The LIGO detection of GW150914 provides an unprecedented opportunity to study the two-body motion of a compact-object binary in the large-velocity, highly nonlinear regime, and to witness the final merger of the binary and the excitation of uniquely relativistic modes of the gravitational field. We carry out several investigations to determine whether GW150914 is consistent with a binary black-hole merger in general relativity. We find that the final remnant's mass and spin, as determined from the low-frequency (inspiral) and high-frequency (postinspiral) phases of the signal, are mutually consistent with the binary black-hole solution in general relativity. Furthermore, the data following the peak of GW150914 are consistent with the least-damped quasinormal mode inferred from the mass and spin of the remnant black hole. By using waveform models that allow for parametrized general-relativity violations during the inspiral and merger phases, we perform quantitative tests on the gravitational-wave phase in the dynamical regime and we determine the first empirical bounds on several high-order post-Newtonian coefficients. We constrain the graviton Compton wavelength, assuming that gravitons are dispersed in vacuum in the same way as particles with mass, obtaining a 90%-confidence lower bound of 10^{13} km. In conclusion, within our statistical uncertainties, we find no evidence for violations of general relativity in the genuinely strong-field regime of gravity.
Collapse
|
33
|
An essential role of ITK in T cell migration to the gut during mouse γ-herpesvirus 68 infection. THE JOURNAL OF IMMUNOLOGY 2016. [DOI: 10.4049/jimmunol.196.supp.79.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Abstract
IL-2-inducible T cell kinase (ITK) is the predominant Tec family kinase in T cells. ITK functions to regulate the magnitude of T cell receptor signaling. Deficiencies in ITK in humans leads to a fatal lymphoproilferative syndrome due to uncontrolled Epstein-Barr virus (EBV) infection. Yet, Itk−/− mice mount protective immune responses against several acute viral infections. To address this dichotomy, we have studied the role of ITK in anti-viral T cell responses to latent γ-herpesvirus infection using mouse γ-herpesvirus 68 (MHV68). Despite a delayed response at D7 post-infection, Itk−/− mice controlled MHV68 replication in the spleen at D14, and WT and Itk−/− mice showed no differences in their viral titers in the spleen during latency. However, MHV68-infected Itk−/− mice (n=11/24) spontaneously developed a severe gastrointestinal pathology after D100 post-infection, whereas WT mice (n=24/24) showed no disease symptoms. Following LPS-induced virus reactivation, Itk−/− mice also showed this pathology in the gut accompanied by a high viral titer in the intestine at various time points during viral latency, while WT mice remained healthy. Consistently, the number of gut-resident T cells were substantially less in Itk−/− mice than WT with or without infection. We also found that P-selectin binding on activated Itk−/− T cells or small molecule inhibitor of ITK (PRN694)-treated WT T cells is greatly impaired. Overall, these data suggest that ITK plays an important role in T cell migration to γ-herpesvirus-infected gut tissue following reactivation from latency.
Collapse
|
34
|
GW150914: Implications for the Stochastic Gravitational-Wave Background from Binary Black Holes. PHYSICAL REVIEW LETTERS 2016; 116:131102. [PMID: 27081965 DOI: 10.1103/physrevlett.116.131102] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Indexed: 06/05/2023]
Abstract
The LIGO detection of the gravitational wave transient GW150914, from the inspiral and merger of two black holes with masses ≳30M_{⊙}, suggests a population of binary black holes with relatively high mass. This observation implies that the stochastic gravitational-wave background from binary black holes, created from the incoherent superposition of all the merging binaries in the Universe, could be higher than previously expected. Using the properties of GW150914, we estimate the energy density of such a background from binary black holes. In the most sensitive part of the Advanced LIGO and Advanced Virgo band for stochastic backgrounds (near 25 Hz), we predict Ω_{GW}(f=25 Hz)=1.1_{-0.9}^{+2.7}×10^{-9} with 90% confidence. This prediction is robustly demonstrated for a variety of formation scenarios with different parameters. The differences between models are small compared to the statistical uncertainty arising from the currently poorly constrained local coalescence rate. We conclude that this background is potentially measurable by the Advanced LIGO and Advanced Virgo detectors operating at their projected final sensitivity.
Collapse
|
35
|
GW150914: The Advanced LIGO Detectors in the Era of First Discoveries. PHYSICAL REVIEW LETTERS 2016; 116:131103. [PMID: 27081966 DOI: 10.1103/physrevlett.116.131103] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Indexed: 05/21/2023]
Abstract
Following a major upgrade, the two advanced detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO) held their first observation run between September 2015 and January 2016. With a strain sensitivity of 10^{-23}/sqrt[Hz] at 100 Hz, the product of observable volume and measurement time exceeded that of all previous runs within the first 16 days of coincident observation. On September 14, 2015, the Advanced LIGO detectors observed a transient gravitational-wave signal determined to be the coalescence of two black holes [B. P. Abbott et al., Phys. Rev. Lett. 116, 061102 (2016)], launching the era of gravitational-wave astronomy. The event, GW150914, was observed with a combined signal-to-noise ratio of 24 in coincidence by the two detectors. Here, we present the main features of the detectors that enabled this observation. At full sensitivity, the Advanced LIGO detectors are designed to deliver another factor of 3 improvement in the signal-to-noise ratio for binary black hole systems similar in mass to GW150914.
Collapse
|
36
|
Observation of Gravitational Waves from a Binary Black Hole Merger. PHYSICAL REVIEW LETTERS 2016; 116:061102. [PMID: 26918975 DOI: 10.1103/physrevlett.116.061102] [Citation(s) in RCA: 1373] [Impact Index Per Article: 171.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Indexed: 05/04/2023]
Abstract
On September 14, 2015 at 09:50:45 UTC the two detectors of the Laser Interferometer Gravitational-Wave Observatory simultaneously observed a transient gravitational-wave signal. The signal sweeps upwards in frequency from 35 to 250 Hz with a peak gravitational-wave strain of 1.0×10(-21). It matches the waveform predicted by general relativity for the inspiral and merger of a pair of black holes and the ringdown of the resulting single black hole. The signal was observed with a matched-filter signal-to-noise ratio of 24 and a false alarm rate estimated to be less than 1 event per 203,000 years, equivalent to a significance greater than 5.1σ. The source lies at a luminosity distance of 410(-180)(+160) Mpc corresponding to a redshift z=0.09(-0.04)(+0.03). In the source frame, the initial black hole masses are 36(-4)(+5)M⊙ and 29(-4)(+4)M⊙, and the final black hole mass is 62(-4)(+4)M⊙, with 3.0(-0.5)(+0.5)M⊙c(2) radiated in gravitational waves. All uncertainties define 90% credible intervals. These observations demonstrate the existence of binary stellar-mass black hole systems. This is the first direct detection of gravitational waves and the first observation of a binary black hole merger.
Collapse
|
37
|
3D reconstruction based on compressed-sensing (CS)-based framework by using a dental panoramic detector. Phys Med 2015; 32:213-7. [PMID: 26494155 DOI: 10.1016/j.ejmp.2015.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2015] [Revised: 09/22/2015] [Accepted: 09/24/2015] [Indexed: 10/22/2022] Open
Abstract
In this work, we propose a practical method that can combine the two functionalities of dental panoramic and cone-beam CT (CBCT) features in one by using a single panoramic detector. We implemented a CS-based reconstruction algorithm for the proposed method and performed a systematic simulation to demonstrate its viability for 3D dental X-ray imaging. We successfully reconstructed volumetric images of considerably high accuracy by using a panoramic detector having an active area of 198.4 mm × 6.4 mm and evaluated the reconstruction quality as a function of the pitch (p) and the angle step (Δθ). Our simulation results indicate that the CS-based reconstruction almost completely recovered the phantom structures, as in CBCT, for p≤2.0 and θ≤6°, indicating that it seems very promising for accurate image reconstruction even for large-pitch and few-view data. We expect the proposed method to be applicable to developing a cost-effective, volumetric dental X-ray imaging system.
Collapse
|
38
|
A Small Molecule Inhibitor of ITK and RLK Impairs Th1 Differentiation and Prevents Colitis Disease Progression. THE JOURNAL OF IMMUNOLOGY 2015; 195:4822-31. [PMID: 26466958 DOI: 10.4049/jimmunol.1501828] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2015] [Accepted: 09/21/2015] [Indexed: 12/29/2022]
Abstract
In T cells, the Tec kinases IL-2-inducible T cell kinase (ITK) and resting lymphocyte kinase (RLK) are activated by TCR stimulation and are required for optimal downstream signaling. Studies of CD4(+) T cells from Itk(-/-) and Itk(-/-)Rlk(-/-) mice have indicated differential roles of ITK and RLK in Th1, Th2, and Th17 differentiation and cytokine production. However, these findings are confounded by the complex T cell developmental defects in these mice. In this study, we examine the consequences of ITK and RLK inhibition using a highly selective and potent small molecule covalent inhibitor PRN694. In vitro Th polarization experiments indicate that PRN694 is a potent inhibitor of Th1 and Th17 differentiation and cytokine production. Using a T cell adoptive transfer model of colitis, we find that in vivo administration of PRN694 markedly reduces disease progression, T cell infiltration into the intestinal lamina propria, and IFN-γ production by colitogenic CD4(+) T cells. Consistent with these findings, Th1 and Th17 cells differentiated in the presence of PRN694 show reduced P-selectin binding and impaired migration to CXCL11 and CCL20, respectively. Taken together, these data indicate that ITK plus RLK inhibition may have therapeutic potential in Th1-mediated inflammatory diseases.
Collapse
|
39
|
CD4+VEGFR1(HIGH) T cell as a novel Treg subset regulates inflammatory bowel disease in lymphopenic mice. Cell Mol Immunol 2015; 12:592-603. [PMID: 26211666 PMCID: PMC4579660 DOI: 10.1038/cmi.2015.71] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2014] [Revised: 06/21/2015] [Accepted: 06/22/2015] [Indexed: 01/07/2023] Open
Abstract
Regulatory T cells (Tregs) are a specialized subpopulation of T cells that control the immune response and thereby maintain immune system homeostasis and tolerance to self-antigens. Many subsets of CD4(+) Tregs have been identified, including Foxp3(+), Tr1, Th3, and Foxp3neg iT(R)35 cells. In this study, we identified a new subset of CD4(+)VEGFR1(high) Tregs that have immunosuppressive capacity. CD4(+)VEGFR1high T cells, which constitute approximately 1.0% of CD4(+) T cells, are hyporesponsive to T-cell antigen receptor stimulation. Surface marker and FoxP3 expression analysis revealed that CD4(+)VEGFR1(high) T cells are distinct from known Tregs. CD4(+)VEGFR1(high) T cells suppressed the proliferation of CD4(+)CD25(-) T cell as efficiently as CD4(+)CD25(high) natural Tregs in a contact-independent manner. Furthermore, adoptive transfer of CD4(+)VEGFR1(+) T cells from wild type to RAG-2-deficient C57BL/6 mice inhibited effector T-cell-mediated inflammatory bowel disease. Thus, we report CD4(+) VEGFR1(high) T cells as a novel subset of Tregs that regulate the inflammatory response in the intestinal tract.
Collapse
|
40
|
Clinical significance of serum bilirubin and gamma-glutamyltransferase levels on coronary atherosclerosis assessed by multidetector computed tomography. Nutr Metab Cardiovasc Dis 2015; 25:677-685. [PMID: 26026212 DOI: 10.1016/j.numecd.2015.03.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2014] [Revised: 01/19/2015] [Accepted: 03/26/2015] [Indexed: 12/19/2022]
Abstract
BACKGROUND AND AIMS Low bilirubin and high gamma-glutamyltransferase (GGT), which are endogenous markers of oxidative stress, confer a higher risk of cardiovascular disease (CVD). We investigated associations between serum concentrations of bilirubin, GGT and coronary atherosclerosis. METHODS AND RESULTS A cross-sectional analysis was performed on 1520 subjects who underwent multidetector computed tomography scans. Coronary atherosclerosis was assessed by coronary artery calcium score (CACS) and obstructive coronary artery disease (OCAD), was defined as the presence of coronary artery stenosis of ≥50%. Total bilirubin (TB) level was negatively correlated with CACS and coronary stenosis whereas GGT level was positively correlated with CACS in men. However, there was no correlation between TB, GGT levels and either CACS or coronary artery stenosis in women. In a multivariate-adjusted model, TB level was inversely associated with a CACS > 100 [odds ratio (OR) per log standard deviation (SD), 0.67; 95% confidence interval (CI), 0.52-0.87], and OCAD (OR per log SD, 0.77; 95% CI, 0.62-0.95) in men. By contrast, GGT level was positively associated with a CACS > 100 (OR per log SD, 1.35; 95% CI, 1.05-1.73) but not with OCAD. Adding TB and GGT to the conventional risk factors increased predictive accuracy for CACS > 100 (net reclassification improvement index [NRI] = 13.1%, P = 0.026; integrated discrimination index [IDI] = 0.024, P = 0.001) and for OCAD (NRI = 12.6%, P = 0.026; IDI = 0.010, P = 0.013). CONCLUSIONS Low TB and high GGT levels were concomitantly associated with coronary atherosclerosis in Korean men. Future studies are needed to elucidate the causal associations of TB and GGT with CVD.
Collapse
|
41
|
Critical role of ITK in mouse γ-herpes virus 68 infection as a model for human immunodeficiency (VIR1P.1140). THE JOURNAL OF IMMUNOLOGY 2015. [DOI: 10.4049/jimmunol.194.supp.74.17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Abstract
IL-2-inducible T cell kinase (ITK) is a Tec family tyrosine kinase predominantly expressed in T cells. In the absence of ITK, the magnitude of T cell receptor (TCR) signaling is greatly reduced, but not abolished, leading to an overall decrease in TCR signaling strength. Recently, various mutations in ITK were identified in patients suffering from a fatal lymphoproliferation due to a failure to control Epstein-Barr virus (EBV) infection. Interestingly, Itk-/- mice have been shown to mount protective responses to several acute virus infections. Thus, we hypothesized that ITK plays an essential role in long-term anti-viral immunity against latent γ-herpes virus infection. To study this, we infected WT and Itk-/- mice with mouse γ-herpes virus 68 (MHV68). Despite a reduced response at D7 post-infection, Itk-/- mice ultimately controlled MHV68 replication in the spleen by D14. After the initial response, both WT and Itk-/- mice showed no difference in their viral titers in the spleen at later time points. However, Itk-/- mice developed severe gastrointestinal pathology following LPS-mediated reactivation of latent MHV68, accompanied by a high viral titer in the intestine. Furthermore, the number of lymphocytes in the intestinal epithelium and lamina propria in naïve Itk-/- mice was substantially less than WT mice. Overall, these data suggest that ITK is essential for anti-viral immunity against γ-herpes virus infection in the gut following reactivation from latency.
Collapse
|
42
|
Abstract
Cancellous allograft bone chips are commonly used in the reconstruction of defects in bone after removal of benign tumours. We investigated the MRI features of grafted bone chips and their change over time, and compared them with those with recurrent tumour. We retrospectively reviewed 66 post-operative MRIs from 34 patients who had undergone curettage and grafting with cancellous bone chips to fill the defect after excision of a tumour. All grafts showed consistent features at least six months after grafting: homogeneous intermediate or low signal intensities with or without scattered hyperintense foci (speckled hyperintensities) on T1 images; high signal intensities with scattered hypointense foci (speckled hypointensities) on T2 images, and peripheral rim enhancement with or without central heterogeneous enhancements on enhanced images. Incorporation of the graft occurred from the periphery to the centre, and was completed within three years. Recurrent lesions consistently showed the same signal intensities as those of pre-operative MRIs of the primary lesions. There were four misdiagnoses, three of which were chondroid tumours. We identified typical MRI features and clarified the incorporation process of grafted cancellous allograft bone chips. The most important characteristics of recurrent tumours were that they showed the same signal intensities as the primary tumours. It might sometimes be difficult to differentiate grafted cancellous allograft bone chips from a recurrent chondroid tumour.
Collapse
|
43
|
Improved upper limits on the stochastic gravitational-wave background from 2009-2010 LIGO and Virgo data. PHYSICAL REVIEW LETTERS 2014; 113:231101. [PMID: 25526109 DOI: 10.1103/physrevlett.113.231101] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Indexed: 06/04/2023]
Abstract
Gravitational waves from a variety of sources are predicted to superpose to create a stochastic background. This background is expected to contain unique information from throughout the history of the Universe that is unavailable through standard electromagnetic observations, making its study of fundamental importance to understanding the evolution of the Universe. We carry out a search for the stochastic background with the latest data from the LIGO and Virgo detectors. Consistent with predictions from most stochastic gravitational-wave background models, the data display no evidence of a stochastic gravitational-wave signal. Assuming a gravitational-wave spectrum of Ω_{GW}(f)=Ω_{α}(f/f_{ref})^{α}, we place 95% confidence level upper limits on the energy density of the background in each of four frequency bands spanning 41.5-1726 Hz. In the frequency band of 41.5-169.25 Hz for a spectral index of α=0, we constrain the energy density of the stochastic background to be Ω_{GW}(f)<5.6×10^{-6}. For the 600-1000 Hz band, Ω_{GW}(f)<0.14(f/900 Hz)^{3}, a factor of 2.5 lower than the best previously reported upper limits. We find Ω_{GW}(f)<1.8×10^{-4} using a spectral index of zero for 170-600 Hz and Ω_{GW}(f)<1.0(f/1300 Hz)^{3} for 1000-1726 Hz, bands in which no previous direct limits have been placed. The limits in these four bands are the lowest direct measurements to date on the stochastic background. We discuss the implications of these results in light of the recent claim by the BICEP2 experiment of the possible evidence for inflationary gravitational waves.
Collapse
|
44
|
Search for gravitational waves associated with γ-ray bursts detected by the interplanetary network. PHYSICAL REVIEW LETTERS 2014; 113:011102. [PMID: 25032916 DOI: 10.1103/physrevlett.113.011102] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Indexed: 05/21/2023]
Abstract
We present the results of a search for gravitational waves associated with 223 γ-ray bursts (GRBs) detected by the InterPlanetary Network (IPN) in 2005-2010 during LIGO's fifth and sixth science runs and Virgo's first, second, and third science runs. The IPN satellites provide accurate times of the bursts and sky localizations that vary significantly from degree scale to hundreds of square degrees. We search for both a well-modeled binary coalescence signal, the favored progenitor model for short GRBs, and for generic, unmodeled gravitational wave bursts. Both searches use the event time and sky localization to improve the gravitational wave search sensitivity as compared to corresponding all-time, all-sky searches. We find no evidence of a gravitational wave signal associated with any of the IPN GRBs in the sample, nor do we find evidence for a population of weak gravitational wave signals associated with the GRBs. For all IPN-detected GRBs, for which a sufficient duration of quality gravitational wave data are available, we place lower bounds on the distance to the source in accordance with an optimistic assumption of gravitational wave emission energy of 10(-2)M⊙c(2) at 150 Hz, and find a median of 13 Mpc. For the 27 short-hard GRBs we place 90% confidence exclusion distances to two source models: a binary neutron star coalescence, with a median distance of 12 Mpc, or the coalescence of a neutron star and black hole, with a median distance of 22 Mpc. Finally, we combine this search with previously published results to provide a population statement for GRB searches in first-generation LIGO and Virgo gravitational wave detectors and a resulting examination of prospects for the advanced gravitational wave detectors.
Collapse
|
45
|
Search for gravitational waves associated with γ-ray bursts detected by the interplanetary network. PHYSICAL REVIEW LETTERS 2014; 113:011102. [PMID: 25032916 DOI: 10.1103/physrevd.89.122004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Indexed: 05/21/2023]
Abstract
We present the results of a search for gravitational waves associated with 223 γ-ray bursts (GRBs) detected by the InterPlanetary Network (IPN) in 2005-2010 during LIGO's fifth and sixth science runs and Virgo's first, second, and third science runs. The IPN satellites provide accurate times of the bursts and sky localizations that vary significantly from degree scale to hundreds of square degrees. We search for both a well-modeled binary coalescence signal, the favored progenitor model for short GRBs, and for generic, unmodeled gravitational wave bursts. Both searches use the event time and sky localization to improve the gravitational wave search sensitivity as compared to corresponding all-time, all-sky searches. We find no evidence of a gravitational wave signal associated with any of the IPN GRBs in the sample, nor do we find evidence for a population of weak gravitational wave signals associated with the GRBs. For all IPN-detected GRBs, for which a sufficient duration of quality gravitational wave data are available, we place lower bounds on the distance to the source in accordance with an optimistic assumption of gravitational wave emission energy of 10(-2)M⊙c(2) at 150 Hz, and find a median of 13 Mpc. For the 27 short-hard GRBs we place 90% confidence exclusion distances to two source models: a binary neutron star coalescence, with a median distance of 12 Mpc, or the coalescence of a neutron star and black hole, with a median distance of 22 Mpc. Finally, we combine this search with previously published results to provide a population statement for GRB searches in first-generation LIGO and Virgo gravitational wave detectors and a resulting examination of prospects for the advanced gravitational wave detectors.
Collapse
|
46
|
Constraints on cosmic strings from the LIGO-Virgo gravitational-wave detectors. PHYSICAL REVIEW LETTERS 2014; 112:131101. [PMID: 24745400 DOI: 10.1103/physrevlett.112.131101] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Indexed: 06/03/2023]
Abstract
Cosmic strings can give rise to a large variety of interesting astrophysical phenomena. Among them, powerful bursts of gravitational waves (GWs) produced by cusps are a promising observational signature. In this Letter we present a search for GWs from cosmic string cusps in data collected by the LIGO and Virgo gravitational wave detectors between 2005 and 2010, with over 625 days of live time. We find no evidence of GW signals from cosmic strings. From this result, we derive new constraints on cosmic string parameters, which complement and improve existing limits from previous searches for a stochastic background of GWs from cosmic microwave background measurements and pulsar timing data. In particular, if the size of loops is given by the gravitational backreaction scale, we place upper limits on the string tension Gμ below 10(-8) in some regions of the cosmic string parameter space.
Collapse
|
47
|
Rhabdomyolysis associated with initiation of febuxostat therapy for hyperuricaemia in a patient with chronic kidney disease. J Clin Pharm Ther 2014; 39:328-30. [PMID: 24612195 DOI: 10.1111/jcpt.12144] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Accepted: 01/27/2014] [Indexed: 01/18/2023]
Abstract
WHAT IS KNOWN AND OBJECTIVE Febuxostat is now recommended as the first-line pharmacological urate-lowering therapy for gout in the American College of Rheumatology guidelines. There is no case of rhabdomyolysis associated with febuxostat among reported side effects of the drug. Our objective is to report on a case of rhabdomyolysis associated with initiation of febuxostat in a patient with chronic kidney disease (CKD). CASE SUMMARY A 73-year-old male patient visited our emergency room due to progressive weakness in both lower extremities starting 3 days earlier. Ten days before presentation, his primary physician had changed his prescription from allopurinol to febuxostat (80 mg) because of poor control of uric acid levels. There was tenderness in both thighs. Initial creatinine kinase (CK) was 7652 U/L (0-170 U/L), and a bone scan using (99m) Tc-HDP revealed strong uptake in soft tissues in both thighs and buttocks. Electromyography (EMG) and nerve conduction velocity (NCV) showed abnormal spontaneous activities (ASA), suggesting myopathy, not nerve damage. On day 7 of admission, after conservative management and febuxostat withdrawal, he could walk on the ward. He is being followed in our clinic as an outpatient with no sequelae. WHAT IS NEW AND CONCLUSION This report is first case of rhabdomyolysis associated with initiation of febuxostat. Febuxostat should be withdrawn when rhabdomyolysis is confirmed.
Collapse
|
48
|
Comparison of mixed venous oxygen saturation after in vitro calibration of pulmonary artery catheter with that of pulmonary arterial blood in patients undergoing living donor liver transplantation. Transplant Proc 2014; 45:1916-9. [PMID: 23769072 DOI: 10.1016/j.transproceed.2012.08.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2012] [Accepted: 08/23/2012] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Mixed venous saturation (SvO2) reflects the balance between oxygen delivery and consumption throughout the body. A multifunction pulmonary artery catheter (PAC) can monitor continuous SvO2 after in vitro calibration (CSvO2), obviating the need for in vivo calibration with pulmonary arterial blood. In critically ill patients CSvO2 has shown a good correlation with measured SvO2 of pulmonary arterial blood using co-oximetry (MSvO2). The aim of this study was to compare CSvO2 and MSvO2 in liver transplantation (OLT) recipients. METHODS We enrolled 44 OLT recipients for comparison with 24 coronary artery bypass graft (CABG) controls free of end-stage liver disease. After anesthetic induction, the PAC was inserted after in vitro calibration and CSvO2 and MSvO2 simultaneously measured. In OLT recipients, additional measurements of CSvO2 and MSvO2 were performed at anhepatic and postreperfusion phases. Pearson's correlation analysis was used to evaluate the correlation between the 2 measurements. A Bland-Altman analysis was used to determine precision of and bias between the 2 measurements. With ±3% regarded to be interchangeable. RESULTS Cardiac output and intrapulmonary shunt in CABG patients were lower than among OLT recipients. OLT recipients, showed a significant correlation between CSvO2 and MSvO2, but the coefficients were different during the three phases of OLT (r = 0.597, 0.753, and 0.756). In addition, bias values between the two measurements were 6.0%, 6.4%, and 2.9% for the preanhepatic, anhepatic, and postreperfusion phases, respectively, with 29.5%, 31.8%, and 50% of them being interchangeable. In contrast CABG patients showed bias in -0.17% with 75% of measurements interchangeable. CONCLUSION While in vitro calibration of the PAC can be used in CABG patients, MSvO2 is higher than CSvO2 in OLT recipients. Therefore, in vivo calibration with pulmonary arterial blood is necessary for accurate monitoring of SvO2 in OLT recipients.
Collapse
|
49
|
A comparison of the BURP and conventional and modified jaw thrust manoeuvres for orotracheal intubation using the Clarus Video System. Anaesthesia 2013; 68:931-7. [PMID: 23841798 DOI: 10.1111/anae.12282] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/21/2013] [Indexed: 11/30/2022]
Abstract
We evaluated the effects of three airway manipulation manoeuvres: (a) conventional (single-handed chin lift); (b) backward, upward and right-sided pressure (BURP) manoeuvre; and (c) modified jaw thrust manoeuvre (two-handed aided by an assistant) on laryngeal view and intubation time using the Clarus Video System in 215 patients undergoing general anaesthesia with orotracheal intubation. In the first part of this study, the laryngeal view was recorded as a modified Cormack-Lehane grade with each manoeuvre. In the second part, intubation was performed using the assigned airway manipulation. The primary outcome was the time to intubation, and the secondary outcomes were the modified Cormack-Lehane grade, the number of attempts and the overall success rate. There were significant differences in modified Cormack-Lehane grade between the three airway manipulations (p < 0.0001). Post-hoc analysis indicated that the modified jaw thrust improved the laryngeal view compared with the conventional (p < 0.0001) and the BURP manoeuvres (p < 0.0001). The BURP worsened the laryngeal view compared with the conventional manoeuvre (p = 0.0132). The time to intubation in the modified jaw thrust group was shorter than with the conventional manoeuvre (p = 0.0004) and the BURP group (p < 0.0001). We conclude that the modified jaw thrust is the most effective manoeuvre at improving the laryngeal view and shortening intubation time with the Clarus Video System.
Collapse
|
50
|
The outcomes of navigation-assisted bone tumour surgery: minimum three-year follow-up. ACTA ACUST UNITED AC 2012; 94:1414-20. [PMID: 23015571 DOI: 10.1302/0301-620x.94b10.28638] [Citation(s) in RCA: 57] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
We evaluated the oncological and functional outcome of 18 patients, whose malignant bone tumours were excised with the assistance of navigation, and who were followed up for more than three years. There were 11 men and seven women, with a mean age of 31.8 years (10 to 57). There were ten operations on the pelvic ring and eight joint-preserving limb salvage procedures. The resection margins were free of tumour in all specimens. The tumours, which were stage IIB in all patients, included osteosarcoma, high-grade chondrosarcoma, Ewing's sarcoma, malignant fibrous histiocytoma of bone, and adamantinoma. The overall three-year survival rate of the 18 patients was 88.9% (95% confidence interval (CI) 75.4 to 100). The three-year survival rate of the patients with pelvic malignancy was 80.0% (95% CI 55.3 to 100), and of the patients with metaphyseal malignancy was 100%. The event-free survival was 66.7% (95% CI 44.9 to 88.5). Local recurrence occurred in two patients, both of whom had a pelvic malignancy. The mean Musculoskeletal Tumor Society functional score was 26.9 points at a mean follow-up of 48.2 months (22 to 79). We suggest that navigation can be helpful during surgery for musculoskeletal tumours; it can maximise the accuracy of resection and minimise the unnecessary sacrifice of normal tissue by providing precise intra-operative three-dimensional radiological information.
Collapse
|