1
|
A quantitative evaluation of aerosol generation during awake tracheal intubation. Anaesthesia 2023; 78:587-597. [PMID: 36710390 DOI: 10.1111/anae.15968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/21/2022] [Indexed: 01/31/2023]
Abstract
Aerosol-generating procedures are medical interventions considered high risk for transmission of airborne pathogens. Tracheal intubation of anaesthetised patients is not high risk for aerosol generation; however, patients often perform respiratory manoeuvres during awake tracheal intubation which may generate aerosol. To assess the risk, we undertook aerosol monitoring during a series of awake tracheal intubations and nasendoscopies in healthy participants. Sampling was undertaken within an ultraclean operating theatre. Procedures were performed and received by 12 anaesthetic trainees. The upper airway was topically anaesthetised with lidocaine and participants were not sedated. An optical particle sizer continuously sampled aerosol. Passage of the bronchoscope through the vocal cords generated similar peak median (IQR [range]) aerosol concentrations to coughing, 1020 (645-1245 [120-48,948]) vs. 1460 (390-2506 [40-12,280]) particles.l-1 respectively, p = 0.266. Coughs evoked when lidocaine was sprayed on the vocal cords generated 91,700 (41,907-166,774 [390-557,817]) particles.l-1 which was significantly greater than volitional coughs (p < 0.001). For 38 nasendoscopies in 12 participants, the aerosol concentrations were relatively low, 180 (120-525 [0-9552]) particles.l-1 , however, five nasendoscopies generated peak aerosol concentrations greater than a volitional cough. Awake tracheal intubation and nasendoscopy can generate high concentrations of respiratory aerosol. Specific risks are associated with lidocaine spray of the larynx, instrumentation of the vocal cords, procedural coughing and deep breaths. Given the proximity of practitioners to patient-generated aerosol, airborne infection control precautions are appropriate when undertaking awake upper airway endoscopy (including awake tracheal intubation, nasendoscopy and bronchoscopy) if respirable pathogens cannot be confidently excluded.
Collapse
|
2
|
Quantitative evaluation of aerosol generation from upper airway suctioning assessed during tracheal intubation and extubation sequences in anaesthetized patients. J Hosp Infect 2022; 124:13-21. [PMID: 35276282 PMCID: PMC9172909 DOI: 10.1016/j.jhin.2022.02.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 02/17/2022] [Accepted: 02/28/2022] [Indexed: 12/14/2022]
Abstract
BACKGROUND Open respiratory suctioning is defined as an aerosol generating procedure (AGP). Laryngopharyngeal suctioning, used to clear secretions during anaesthesia, is widely managed as an AGP. However, it is uncertain whether upper airway suctioning should be designated as an AGP due to the lack of both aerosol and epidemiological evidence. AIM To assess the relative risk of aerosol generation by upper airway suctioning during tracheal intubation and extubation in anaesthetized patients. METHODS This prospective environmental monitoring study was undertaken in an ultraclean operating theatre setting to assay aerosol concentrations during intubation and extubation sequences, including upper airway suctioning, for patients undergoing surgery (N=19). An optical particle sizer (particle size 0.3-10 μm) sampled aerosol 20 cm above the patient's mouth. Baseline recordings (background, tidal breathing and volitional coughs) were followed by intravenous induction of anaesthesia with neuromuscular blockade. Four periods of laryngopharyngeal suctioning were performed with a Yankauer sucker: pre-laryngoscopy, post-intubation, pre-extubation and post-extubation. FINDINGS Aerosol was reliably detected {median 65 [interquartile range (IQR) 39-259] particles/L} above background [median 4.8 (IQR 1-7) particles/L, P<0.0001] when sampling in close proximity to the patient's mouth during tidal breathing. Upper airway suctioning was associated with a much lower average aerosol concentration than breathing [median 6.0 (IQR 0-12) particles/L, P=0.0007], and was indistinguishable from background (P>0.99). Peak aerosol concentrations recorded during suctioning [median 45 (IQR 30-75) particles/L] were much lower than during volitional coughs [median 1520 (IQR 600-4363) particles/L, P<0.0001] and tidal breathing [median 540 (IQR 300-1826) particles/L, P<0.0001]. CONCLUSION Upper airway suctioning during airway management was not associated with a higher aerosol concentration compared with background, and was associated with a much lower aerosol concentration compared with breathing and coughing. Upper airway suctioning should not be designated as a high-risk AGP.
Collapse
|
3
|
Accurate Measurement of the Optical Properties of Single Aerosol Particles Using Cavity Ring-Down Spectroscopy. J Phys Chem A 2022; 126:2619-2631. [PMID: 35467353 PMCID: PMC9082593 DOI: 10.1021/acs.jpca.2c01246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
![]()
New approaches for
the sensitive and accurate quantification of
aerosol optical properties are needed to improve the current understanding
of the unique physical chemistry of airborne particles and to explore
their roles in fields as diverse as chemical manufacturing, healthcare,
and atmospheric science. We have pioneered the use of cavity ring-down
spectroscopy (CRDS), with concurrent angularly resolved elastic light
scattering measurements, to interrogate the optical properties of
single aerosol particles levitated in optical and electrodynamic traps.
This approach enables the robust quantification of optical properties
such as extinction cross sections for individual particles of known
size. Our measurements can now distinguish the scattering and absorption
contributions to the overall light extinction, from which the real
and imaginary components of the complex refractive indices can be
retrieved and linked to chemical composition. In this Feature Article,
we show that this innovative measurement platform enables accurate
and precise optical measurements for spherical and nonspherical particles,
whether nonabsorbing or absorbing at the CRDS probe wavelength. We
discuss the current limitations of our approach and the key challenges
in physical and atmospheric chemistry that can now be addressed by
CRDS measurements for single aerosol particles levitated in controlled
environments.
Collapse
|
4
|
A quantitative evaluation of aerosol generation during supraglottic airway insertion and removal. Anaesthesia 2021; 76:1577-1584. [PMID: 34287820 DOI: 10.1111/anae.15542] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/18/2021] [Indexed: 12/30/2022]
Abstract
Many guidelines consider supraglottic airway use to be an aerosol-generating procedure. This status requires increased levels of personal protective equipment, fallow time between cases and results in reduced operating theatre efficiency. Aerosol generation has never been quantitated during supraglottic airway use. To address this evidence gap, we conducted real-time aerosol monitoring (0.3-10-µm diameter) in ultraclean operating theatres during supraglottic airway insertion and removal. This showed very low background particle concentrations (median (IQR [range]) 1.6 (0-3.1 [0-4.0]) particles.l-1 ) against which the patient's tidal breathing produced a higher concentration of aerosol (4.0 (1.3-11.0 [0-44]) particles.l-1 , p = 0.048). The average aerosol concentration detected during supraglottic airway insertion (1.3 (1.0-4.2 [0-6.2]) particles.l-1 , n = 11), and removal (2.1 (0-17.5 [0-26.2]) particles.l-1 , n = 12) was no different to tidal breathing (p = 0.31 and p = 0.84, respectively). Comparison of supraglottic airway insertion and removal with a volitional cough (104 (66-169 [33-326]), n = 27), demonstrated that supraglottic airway insertion/removal sequences produced <4% of the aerosol compared with a single cough (p < 0.001). A transient aerosol increase was recorded during one complicated supraglottic airway insertion (which initially failed to provide a patent airway). Detailed analysis of this event showed an atypical particle size distribution and we subsequently identified multiple sources of non-respiratory aerosols that may be produced during airway management and can be considered as artefacts. These findings demonstrate supraglottic airway insertion/removal generates no more bio-aerosol than breathing and far less than a cough. This should inform the design of infection prevention strategies for anaesthetists and operating theatre staff caring for patients managed with supraglottic airways.
Collapse
|
5
|
Analysis of body condition indices reveals different ecotypes of the Antillean manatee. Sci Rep 2021; 11:19451. [PMID: 34593916 PMCID: PMC8484672 DOI: 10.1038/s41598-021-98890-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 09/08/2021] [Indexed: 11/09/2022] Open
Abstract
Assessing the body condition of wild animals is necessary to monitor the health of the population and is critical to defining a framework for conservation actions. Body condition indices (BCIs) are a non-invasive and relatively simple means to assess the health of individual animals, useful for addressing a wide variety of ecological, behavioral, and management questions. The Antillean manatee (Trichechus manatus manatus) is an endangered subspecies of the West Indian manatee, facing a wide variety of threats from mostly human-related origins. Our objective was to define specific BCIs for the subspecies that, coupled with additional health, genetic and demographic information, can be valuable to guide management decisions. Biometric measurements of 380 wild Antillean manatees captured in seven different locations within their range of distribution were obtained. From this information, we developed three BCIs (BCI1 = UG/SL, BCI2 = W/SL3, BCI3 = W/(SL*UG2)). Linear models and two-way ANCOVA tests showed significant differences of the BCIs among sexes and locations. Although our three BCIs are suitable for Antillean manatees, BCI1 is more practical as it does not require information about weight, which can be a metric logistically difficult to collect under particular circumstances. BCI1 was significantly different among environments, revealing that the phenotypic plasticity of the subspecies have originated at least two ecotypes-coastal marine and riverine-of Antillean manatees.
Collapse
|
6
|
High time resolution measurements of droplet evaporation kinetics and particle crystallisation. Phys Chem Chem Phys 2021; 23:18568-18579. [PMID: 34612393 DOI: 10.1039/d1cp02840e] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
A refined technique for observing the complete evaporation behaviour of free-falling droplets, from droplet generation to complete solvent evaporation, with ultra-high time resolution is introduced and benchmarked. High-resolution phase-delay stroboscopic imaging is employed to simultaneously resolve the evolving droplet morphology, geometric and aerodynamic diameters, throughout the evaporative lifetime with a user-controlled < μs timescale. This allows rapid, complex morphological changes, such as crystallisation events, to be clearly observed and the corresponding mechanisms to be inferred. The dried particles are sampled for offline SEM analysis and the observed morphologies compared to the inflight imaging. Density changes can be calculated directly from the deviation between the geometric and aerodynamic diameters. The full capabilities of the new technique are demonstrated by examination of the different evaporation behaviours and crystallisation mechanisms for aqueous sodium chloride droplets evaporating under different ambient relative humidity (RH) conditions. The crystallisation window, defined as the time taken from initial to complete crystallisation, is shown to be RH dependent, extending from 0.03 s at 20% RH and 0.13 s at 40% RH. The different crystallisation mechanisms observed during the experiments are also clearly reflected in the final structure of the dry particles, with multi-crystal structures produced at low RH compared to single-crystal structures at higher RH. It is anticipated that this technique will unlock measurements which explore the evaporation behaviour and crystallisation mechanisms for rapid, complex droplet drying events, and with increasingly non-ideal solutions, relevant to industrial applications.
Collapse
|
7
|
A quantitative evaluation of aerosol generation during tracheal intubation and extubation: a reply. Anaesthesia 2020; 76 Suppl 3:16-18. [PMID: 33368170 DOI: 10.1111/anae.15345] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/17/2020] [Indexed: 11/26/2022]
|
8
|
A quantitative evaluation of aerosol generation during tracheal intubation and extubation. Anaesthesia 2020; 76:174-181. [PMID: 33022093 PMCID: PMC7675579 DOI: 10.1111/anae.15292] [Citation(s) in RCA: 129] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2020] [Indexed: 12/18/2022]
Abstract
The potential aerosolised transmission of severe acute respiratory syndrome coronavirus‐2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol‐generating procedures to inform risk assessments. To address this evidence gap, we conducted real‐time, high‐resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l−1) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l−1, n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l−1, n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l−1, n = 10) which was 15‐fold greater than intubation (p = 0.0004) but 35‐fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol‐generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high‐risk aerosol‐generating procedure. These novel findings from real‐time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol‐generating procedure and the associated precautions for routine anaesthetic airway management.
Collapse
|
9
|
Distinguishing bone and soft tissue infections mimicking sarcomas requires multimodal multidisciplinary team assessment. Ann R Coll Surg Engl 2019; 101:405-410. [PMID: 31155889 DOI: 10.1308/rcsann.2019.0040] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
INTRODUCTION The aims of this study were to report the presenting characteristics and identify how best to distinguish bone and soft-tissue infections that mimic sarcomas. MATERIALS AND METHODS A total of 238 (211 osteomyelitis and 27 soft-tissue infections) patients referred to a tertiary sarcoma multidisciplinary team with suspected sarcoma who were ultimately diagnosed with a bone or soft tissue infection were included. Data from a prospectively collated database was analysed retrospectively. RESULTS Of all possible bone and soft-tissue sarcoma referrals, a diagnosis of infection was made in 2.1% and 0.7%, respectively. Median age was 18 years in the osteomyelitis group and 46 years in the soft-tissue infection group. In the osteomyelitis group, the most common presenting features were pain (85.8%) and swelling (32.7%). In the soft-tissue infection group, the most common clinical features were swelling (96.3%) and pain (70.4%). Those in the soft-tissue group were more likely to have raised inflammatory markers. Radiological investigations were unable to discern between tumour or infection in 59.7% of osteomyelitis and 81.5% of soft-tissue infection cases. No organism was identified in 64.9% of those who had a percutaneous biopsy culture. CONCLUSIONS This study has highlighted that infection is frequently clinically indistinguishable from sarcoma and remains a principle non-neoplastic differential diagnosis. When patients are investigated for suspected sarcoma, infections can be missed due to falsely negative radiological investigations and percutaneous biopsy. As no single clinical, biochemical or radiological feature or investigation can be relied upon for diagnosis, clinicians should have a low threshold for tissue biopsy and discussion in a sarcoma multidisciplinary team meeting.
Collapse
|
10
|
Studies of competing evaporation rates of multiple volatile components from a single binary-component aerosol droplet. Phys Chem Chem Phys 2019; 21:9709-9719. [PMID: 31025989 DOI: 10.1039/c9cp01158g] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The simultaneous evaporation and condensation of multiple volatile components from multicomponent aerosol droplets leads to changes in droplet size, composition and temperature. Measurements and models that capture and predict these dynamic aerosol processes are key to understanding aerosol microphysics in a broad range of contexts. We report measurements of the evaporation kinetics of droplets (initially ∼25 μm radius) formed from mixtures of ethanol and water levitated within a electrodynamic balance over timescales spanning 500 ms to 6 s. Measurements of evaporation into a gas phase of varied relative humidity and temperature are shown to compare well with predictions from a numerical model. We show that water condensation from the gas phase can occur concurrently with ethanol evaporation from aqueous-ethanol droplets. Indeed, water can condense so rapidly during the evaporation of a pure ethanol droplet in a humid environment, driven by the evaporative cooling the droplet experiences, that the droplet becomes pure water within 0.4 s.
Collapse
|
11
|
Surveys of environmental DNA (eDNA): a new approach to estimate occurrence in Vulnerable manatee populations. ENDANGER SPECIES RES 2018. [DOI: 10.3354/esr00880] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
12
|
|
13
|
Quantum Critical Quasiparticle Scattering within the Superconducting State of CeCoIn_{5}. PHYSICAL REVIEW LETTERS 2016; 117:016601. [PMID: 27419578 DOI: 10.1103/physrevlett.117.016601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Indexed: 06/06/2023]
Abstract
The thermal conductivity κ of the heavy-fermion metal CeCoIn_{5} was measured in the normal and superconducting states as a function of temperature T and magnetic field H, for a current and field parallel to the [100] direction. Inside the superconducting state, when the field is lower than the upper critical field H_{c2}, κ/T is found to increase as T→0, just as in a metal and in contrast to the behavior of all known superconductors. This is due to unpaired electrons on part of the Fermi surface, which dominate the transport above a certain field. The evolution of κ/T with field reveals that the electron-electron scattering (or transport mass m^{⋆}) of those unpaired electrons diverges as H→H_{c2} from below, in the same way that it does in the normal state as H→H_{c2} from above. This shows that the unpaired electrons sense the proximity of the field-tuned quantum critical point of CeCoIn_{5} at H^{⋆}=H_{c2} even from inside the superconducting state. The fact that the quantum critical scattering of the unpaired electrons is much weaker than the average scattering of all electrons in the normal state reveals a k-space correlation between the strength of pairing and the strength of scattering, pointing to a common mechanism, presumably antiferromagnetic fluctuations.
Collapse
|
14
|
Universal heat conduction in the iron arsenide superconductor KFe2As2: evidence of a d-wave state. PHYSICAL REVIEW LETTERS 2012; 109:087001. [PMID: 23002766 DOI: 10.1103/physrevlett.109.087001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2012] [Indexed: 06/01/2023]
Abstract
The thermal conductivity κ of the iron arsenide superconductor KFe2As2 was measured down to 50 mK for a heat current parallel and perpendicular to the tetragonal c axis. A residual linear term at T→0, κ(0)/T is observed for both current directions, confirming the presence of nodes in the superconducting gap. Our value of κ(0)/T in the plane is equal to that reported by Dong et al. [Phys. Rev. Lett. 104, 087005 (2010)] for a sample whose residual resistivity ρ(0) was 10 times larger. This independence of κ(0)/T on impurity scattering is the signature of universal heat transport, a property of superconducting states with symmetry-imposed line nodes. This argues against an s-wave state with accidental nodes. It favors instead a d-wave state, an assignment consistent with five additional properties: the magnitude of the critical scattering rate Γ(c) for suppressing T(c) to zero; the magnitude of κ(0)/T, and its dependence on current direction and on magnetic field; the temperature dependence of κ(T).
Collapse
|
15
|
A randomised, controlled study to quantify the benefits of community pharmacist interventions on the prescribing of cardiovascular drugs in general practice. INTERNATIONAL JOURNAL OF PHARMACY PRACTICE 2011. [DOI: 10.1111/j.2042-7174.2001.tb01086.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Abstract
Focal points
Collapse
|
16
|
Abstract
We present evidence that aerosol droplets, approximately 1-2microm in diameter, can be optically bound over a 4mm distance within a volume formed by the overlap of the central cores and rings of two counterpropagating Bessel beams. The sizes of the individual polydisperse aerosol particles can be estimated from the angular variation of the elastic light scattering. Scattered light from the two orthogonally polarized trapping beams and from a Gaussian probe beam of different wavelength can be used to provide independent estimations of size. The coalescence of two droplets was observed and characterized.
Collapse
|
17
|
Doping dependence of heat transport in the iron-arsenide superconductor Ba(Fe(1-x)Co(x))2As2: from isotropic to a strongly k-dependent gap structure. PHYSICAL REVIEW LETTERS 2010; 104:067002. [PMID: 20366850 DOI: 10.1103/physrevlett.104.067002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2009] [Revised: 12/18/2009] [Indexed: 05/29/2023]
Abstract
The temperature and magnetic field dependence of the in-plane thermal conductivity kappa of the iron-arsenide superconductor Ba(Fe(1-x)Co(x))2As2 was measured down to T approximately 50 mK and up to H = 15 T as a function of Co concentration x in the range 0.048 < or = x < or = 0.114. At H = 0, a negligible residual linear term in kappa/T as T-->0 at all x shows that the superconducting gap has no nodes in the ab plane anywhere in the phase diagram. However, while the slow H dependence of kappa(H) at T-->0 in the underdoped regime is consistent with a superconducting gap that is large everywhere on the Fermi surface, the rapid increase in kappa(H) observed in the overdoped regime shows that the gap acquires a deep minimum somewhere on the Fermi surface. Outside the antiferromagnetic-orthorhombic phase, the superconducting gap structure has a strongly k-dependent amplitude.
Collapse
|
18
|
Optical properties of micrometer size water droplets studied by cavity ringdown spectroscopy. APPLIED OPTICS 2007; 46:6142-50. [PMID: 17712379 DOI: 10.1364/ao.46.006142] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Optical extinction by homogeneous, pure water droplets of 30 to 70 microm diameter produced by a vibrating orifice aerosol generator has been studied by pulsed cavity ringdown (CRD) spectroscopy at lambda=560 nm under ambient conditions. Experimental sensitivity of better than 1% achieved in measurements of CRD times enabled detection of changes in laser light losses per pass due to changes in the number and size of particles within the laser beam volume. By systematically changing the droplet size in the cavity while recording the CRD time, a periodic modulation in the value of the loss per pass was observed. The modulation is caused by the oscillatory nature of the extinction efficiency, which was subsequently inferred and compared with the results of theoretical calculations based on Mie theory.
Collapse
|
19
|
Direct measurements of the axial displacement and evolving size of optically trapped aerosol droplets. ACTA ACUST UNITED AC 2007. [DOI: 10.1088/1464-4258/9/8/s10] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
20
|
Abstract
We characterize the ability of Gaussian and Bessel beams to guide water, ethanol and dodecane aerosol droplets. Droplets produced from a nebuliser source are trapped using radiation pressure and then by varying the beam power are controllably guided in a vertical direction. The use of a zeroth-order Bessel beam, which has a non-diffracting thin core, is shown to improve guiding distances over a comparable Gaussian beam by more than three times with guiding distances of up to 2.75mm for dodecane droplets. We discuss the applications for this work in the context of tools for optically manipulating airborne particles.
Collapse
|
21
|
Prescribing antidepressants in general practice. Prescribing rates vary widely between practices. BMJ (CLINICAL RESEARCH ED.) 1997; 314:828. [PMID: 9081016 PMCID: PMC2126207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
22
|
|
23
|
Combinations of paclitaxel and etoposide in the treatment of lung cancer. Semin Oncol 1996; 23:21-5. [PMID: 8996593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Paclitaxel (Taxol; Bristol-Myers Squibb Company, Princeton, NJ) and etoposide are two chemotherapy agents with broad cytotoxic activity but different mechanisms of action and resistance. Previous in vitro studies of their combined cytotoxicity have yielded conflicting results. We evaluated the effects of drug scheduling in cell growth inhibition in lung and breast human cancer cell lines. A clonogenic assay with either simultaneous or sequential 24-hour incubation of paclitaxel and etoposide was used to assess growth inhibition, and the combination index was used to evaluate drug interactions. In these studies, including the A549 human lung cancer cell line, mild antagonism (combination index, > 1) was observed with concurrent exposure of paclitaxel and etoposide, but synergism (combination index, < 1) was observed when the drugs were incubated sequentially. In view of the wide range of antitumor activity of both paclitaxel and etoposide, and the potential importance and clinical impact of optimizing drug doses and schedules, we recently completed a phase I study with the following objectives: (1) to determine the maximum tolerated dose of paclitaxel given intravenously on day 10 after 10 days of oral etoposide and (2) to investigate the toxicity profile of this combination of agents. Three consecutive cohorts consisting of a total of 29 patients with various measurable or assessable tumors were treated with paclitaxel by intravenous infusion over 3 hours after receiving 10 days of etoposide 50 mg orally twice daily. Conclusions for this clinical study were that the combination was feasible and tolerable and had demonstrated antitumor activity in a group of mostly pretreated patients. The recommended doses for phase II studies were etoposide 50 mg twice daily for 10 days followed by paclitaxel 150 mg/m2 intravenously over 3 hours. A phase II study in patients with extensive small cell lung cancer, with appropriate translational studies, has been initiated.
Collapse
|
24
|
Variations in general practice prescribing costs and implications for budget setting. HEALTH ECONOMICS 1994; 3:47-56. [PMID: 8167799 DOI: 10.1002/hec.4730030107] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Indicative prescribing amounts, and the equivalent prescribing element of funds in the case of fund-holding practices, are now an established part of UK general practice. This paper examines the implications of variations in GP prescribing behaviour for the determination of prescribing budgets. Using regression analysis, the extent to which variations in total practice prescribing costs can be explained by factors suggested for inclusion in a weighted capitation formula is established. The results indicate that 97% of the variation in practice prescribing costs can be explained by differences in practice list size, the proportion of patients aged 65 years and over, the proportion of patients living in 'deprived areas' and whether or not the practice qualifies for 'inducement payments'. The implications of the results for budget setting are discussed. A resource allocation formula based on regression analysis of expenditures can be used to promote horizontal equity in terms of equal budgets for equal need. However, its implications for vertical equity and efficiency are more ambiguous.
Collapse
|