1
|
Pulmonary function testing dataset of pressure and flow, dynamic circumference, heart rate, and aeration monitoring. Data Brief 2024; 54:110386. [PMID: 38646196 PMCID: PMC11033070 DOI: 10.1016/j.dib.2024.110386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 03/27/2024] [Accepted: 03/29/2024] [Indexed: 04/23/2024] Open
Abstract
Respiratory data was collected from 20 subjects, with an even sex distribution, in the low-risk clinical unit at the University of Canterbury. Ethical consent for this trial was granted by the University of Canterbury Human Research Ethics Committee (Ref: HREC 2023/30/LR-PS). Respiratory data were collected, for each subject, over three tests consisting of: 1) increasing set PEEP from a starting point of ZEEP using a CPAP machine; 2) test 1 repeated with two simulated apnoea's (breath holds) at each set PEEP; and 3) three forced expiratory manoeuvres at ZEEP. Data were collected using a custom pressure and flow sensor device, ECG, PPG, Garmin HRM Dual heartrate belt, and a Dräeger PulmoVista 500 Electrical Impedance Tomography (EIT) machine. Subject demographic data was also collected prior to the trial, in a questionnaire, with measurement equipment available. These data aim to inform the development of pulmonary mechanics models and titration algorithms.
Collapse
|
2
|
Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24. J Diabetes Sci Technol 2024; 18:709-713. [PMID: 36476068 PMCID: PMC11089868 DOI: 10.1177/19322968221142316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
With the prevalence of diabetes higher than ever, governments and people with diabetes are facing significant treatment and indirect costs associated with managing their condition. An ultra-low-cost insulin pump is a possible solution to improving health disparities. This article presents test results for an insulin-pump built from low-cost components (bill of materials < $US100). All testing was completed in accordance with IEC60601-2-24, and results were benchmarked against a commercial pump. Results showed the ultra-low-cost pump has comparable accuracy to the commercially available insulin pump with testing displaying an overall accuracy of 0.089% and -0.392%, respectively. These results show that an ultra-low-cost pump can accurately deliver insulin in limited bench testing. Testing in other environments and scenarios is required to fully meet IEC60601-2-24 standards.
Collapse
|
3
|
Preserving multi-dimensional information: A hypersphere method for parameter space analysis. Heliyon 2024; 10:e28822. [PMID: 38601671 PMCID: PMC11004565 DOI: 10.1016/j.heliyon.2024.e28822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 03/25/2024] [Indexed: 04/12/2024] Open
Abstract
Background Physiological modelling often involves models described by large numbers of variables and significant volumes of clinical data. Mathematical interpretation of such models frequently necessitates analysing data points in high-dimensional spaces. Existing algorithms for analysing high-dimensional points either lose important dimensionality or do not describe the full position of points. Hence, there is a need for an algorithm which preserves this information. Methods The most-distant uncovered point (MDUP) hypersphere method is a binary classification approach which defines a collection of equidistant N-dimensional points as the union of hyperspheres. The method iteratively generates hyperspheres at the most distant point in the interest region not yet contained within any hypersphere, until the entire region of interest is defined by the union of all generated hyperspheres. This method is tested on a 7-dimensional space with up to 35.8 million points representing feasible and infeasible spaces of model parameters for a clinically validated cardiovascular system model. Results For different numbers of input points, the MDUP hypersphere method tends to generate large spheres away from the boundary of feasible and infeasible points, but generates the greatest number of relatively much smaller spheres around the boundary of the region of interest to fill this space. Runtime scales quadratically, in part because the current MDUP implementation is not parallelised. Conclusions The MDUP hypersphere method can define points in a space of any dimension using only a collection of centre points and associated radii, making the results easily interpretable. It can identify large continuous regions, and in many cases capture the general structure of a region in only a relative few hyperspheres. The MDUP method also shows promise for initialising optimisation algorithm starting conditions within pre-defined feasible regions of model parameter spaces, which could improve model identifiability and the quality of optimisation results.
Collapse
|
4
|
Obstructive respiratory disease simulation device. HARDWAREX 2024; 17:e00512. [PMID: 38333423 PMCID: PMC10850955 DOI: 10.1016/j.ohx.2024.e00512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 01/21/2024] [Accepted: 01/24/2024] [Indexed: 02/10/2024]
Abstract
Respiratory disease is a major contributor to healthcare costs, as well as increasing morbidity and early mortality. The device presented is used to simulate the effects of Chronic Obstructive Pulmonary Disease (COPD) in healthy people. The intended use is to provide data equivalent to COPD data measured from those who are ill for initial validation of respiratory mechanics models. It would thus eliminate the need to test unhealthy and/or fragile subjects, or the need for invasive or costly equipment based test methods. The device is used in conjunction with an open-access venturi-based flow sensor, to measure pressure, flow, and breath tidal volume. The device simulates the pressure and flow profiles of a person who has COPD including the non-linear increased resistance to end-exhalation and gas trapping. To achieve this non-linearity, a combination of high and low resistance outlets is used. Thus, the simulator allows the collection of patient-specific COPD-like breathing data in a non-invasive manner from healthy subjects. The device is low-cost with the majority of the parts 3D printed using a Prusa mini 3D printer and PLA filament.
Collapse
|
5
|
Respiratory monitoring dataset, with rapid expiratory occlusions, over increasing positive airway pressure ventilation. Data Brief 2024; 52:109874. [PMID: 38146285 PMCID: PMC10749260 DOI: 10.1016/j.dib.2023.109874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 12/27/2023] Open
Abstract
Resting breathing data was collected from 80 smokers, vapers, asthmatics, and otherwise healthy people in the low-risk clinical unit at the University of Canterbury. Subjects were asked to breathe normally through a full-face mask connected to a Fisher and Paykel Healthcare SleepStyle SPSCAA CPAP device. PEEP (Positive End-Expiratory Pressure) support was increased from 4 to 12 cmH2O in 0.5 cmH2O increments. Data was also collected during resting breathing at ZEEP (0 cmH2O) before and after the PEEP trial. The trial was conducted under University of Canterbury Human Research Ethics Committee consent (Ref: HREC 2023/04/LR-PS). Data was collected by and Dräeger PulmoVista 500 EIT machine and a custom Venturi-based pressure and flow sensor device connected in series with the CPAP and full-face mask. The outlined dataset includes pressure, flow, volume, dynamic circumference (thoracic and abdominal, and cross-sectional aeration. Subject demographic data was self-reported using a questionnaire given prior to the trial.
Collapse
|
6
|
Simulated obstructive respiratory disease dataset over increasing positive end-expiratory pressure. Data Brief 2024; 52:109903. [PMID: 38161653 PMCID: PMC10754699 DOI: 10.1016/j.dib.2023.109903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 11/27/2023] [Accepted: 11/28/2023] [Indexed: 01/03/2024] Open
Abstract
The breathing dataset presented is collected from 20 healthy individuals at the University of Canterbury using a device to simulate the pressure and flow profiles of obstructive pulmonary disease. Specifically, the expiratory non-linear resistance, which generates the characteristic expiratory pressure-flow loop lobe seen in obstructive disease. Ethical consent for the trial was granted by the University of Canterbury Human Research Ethics Committee (Ref: HREC 2022/26/LR). Data was collected using an open-source data collection device connected to a Fisher and Paykel Healthcare SleepStyle SPSCAA CPAP. The trial was conducted at CPAP PEEP levels of 4 and 8 cmH2O, as well as at ZEEP (0 cmH2O) with no CPAP attached. The simulation device was a modular device connected to the expiratory pathway, consisting of a free volume diversion and fixed high resistance outlet. Three simulation levels were selected for testing, achieved by changing the size of the elastic free volume. The intended use of this dataset is for the initial validation and development of respiratory pulmonary mechanics models, using data collected from healthy people with simulated disease prior to clinical testing.
Collapse
|
7
|
Pulmonary response prediction through personalized basis functions in a virtual patient model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107988. [PMID: 38171168 DOI: 10.1016/j.cmpb.2023.107988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 11/16/2023] [Accepted: 12/17/2023] [Indexed: 01/05/2024]
Abstract
BACKGROUND AND OBJECTIVE Recruitment maneuvers with subsequent positive-end-expiratory-pressure (PEEP) have proven effective in recruiting lung volume and preventing alveoli collapse. However, determining a safe, effective, and patient-specific PEEP is not standardized, and this more optimal PEEP level evolves with patient condition, requiring personalised monitoring and care approaches to maintain optimal ventilation settings. METHODS This research examines 3 physiologically relevant basis function sets (exponential, parabolic, cumulative) to enable better prediction of elastance evolution for a virtual patient or digital twin model of MV lung mechanics, including novel elements to model and predict distension elastance. Prediction accuracy and robustness are validated against recruitment maneuver data from 18 volume-controlled ventilation (VCV) patients at 7 different baseline PEEP levels (0 to 12 cmH2O) and 14 pressure-controlled ventilation (PCV) patients at 4 different baseline PEEP levels (6 to 12 cmH2O), yielding 623 and 294 prediction cases, respectively. Predictions were made up to 12 cmH2O of added PEEP ahead, covering 6 × 2 cmH2O PEEP steps. RESULTS The 3 basis function sets yield median absolute peak inspiratory pressure (PIP) prediction error of 1.63 cmH2O for VCV patients, and median peak inspiratory volume (PIV) prediction error of 0.028 L for PCV patients. The exponential basis function set yields a better trade-off of overall performance across VCV and PCV prediction than parabolic and cumulative basis function sets from other studies. Comparing predicted and clinically measured distension prediction in VCV demonstrated consistent, robust high accuracy with R2 = 0.90-0.95. CONCLUSIONS The results demonstrate recruitment mechanics are best captured by an exponential basis function across different mechanical ventilation modes, matching physiological expectations, and accurately capture, for the first time, distension mechanics to within 5-10 % accuracy. Enabling the risk of lung injury to be predicted before changing ventilator settings. The overall outcomes significantly extend and more fully validate this digital twin or virtual mechanical ventilation patient model.
Collapse
|
8
|
Non-Invasive Assessment of Abdominal/Diaphragmatic and Thoracic/Intercostal Spontaneous Breathing Contributions. SENSORS (BASEL, SWITZERLAND) 2023; 23:9774. [PMID: 38139620 PMCID: PMC10747041 DOI: 10.3390/s23249774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/07/2023] [Accepted: 12/11/2023] [Indexed: 12/24/2023]
Abstract
(1) Background: Technically, a simple, inexpensive, and non-invasive method of ascertaining volume changes in thoracic and abdominal cavities are required to expedite the development and validation of pulmonary mechanics models. Clinically, this measure enables the real-time monitoring of muscular recruitment patterns and breathing effort. Thus, it has the potential, for example, to help differentiate between respiratory disease and dysfunctional breathing, which otherwise can present with similar symptoms such as breath rate. Current automatic methods of measuring chest expansion are invasive, intrusive, and/or difficult to conduct in conjunction with pulmonary function testing (spontaneous breathing pressure and flow measurements). (2) Methods: A tape measure and rotary encoder band system developed by the authors was used to directly measure changes in thoracic and abdominal circumferences without the calibration required for analogous strain-gauge-based or image processing solutions. (3) Results: Using scaling factors from the literature allowed for the conversion of thoracic and abdominal motion to lung volume, combining motion measurements correlated to flow-based measured tidal volume (normalised by subject weight) with R2 = 0.79 in data from 29 healthy adult subjects during panting, normal, and deep breathing at 0 cmH2O (ZEEP), 4 cmH2O, and 8 cmH2O PEEP (positive end-expiratory pressure). However, the correlation for individual subjects is substantially higher, indicating size and other physiological differences should be accounted for in scaling. The pattern of abdominal and chest expansion was captured, allowing for the analysis of muscular recruitment patterns over different breathing modes and the differentiation of active and passive modes. (4) Conclusions: The method and measuring device(s) enable the validation of patient-specific lung mechanics models and accurately elucidate diaphragmatic-driven volume changes due to intercostal/chest-wall muscular recruitment and elastic recoil.
Collapse
|
9
|
Respiratory pressure and split flow data collection device with rapid occlusion attachment. HARDWAREX 2023; 16:e00489. [PMID: 38058767 PMCID: PMC10696101 DOI: 10.1016/j.ohx.2023.e00489] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 11/10/2023] [Indexed: 12/08/2023]
Abstract
Respiratory model-based methods require datasets containing enough dynamics to ensure model identifiability for development and validation. Rapid expiratory occlusion has been used to identify elastance and resistance within a single breath. Currently accepted practice for rapid expiratory occlusion involves a 100 ms occlusion of the expiratory pathway. This article presents a low-cost modular rapid shutter attachment to enable identification of passive respiratory mechanics. Shuttering faster than 100 ms creates rapid expiratory occlusion without the added dynamics of muscular response to shutter closure, by eliminating perceived expiratory blockage via high shutter speed. The shutter attachment fits onto a non-invasive venturi-based flow meter with separated inspiratory and expiratory pathways, established using one-way valves. Overall, these elements allow comprehensive collection of respiratory pressure and flow datasets with relatively very rapid expiratory occlusion.
Collapse
|
10
|
Low-cost, low-power, clockwork syringe pump. HARDWAREX 2023; 16:e00469. [PMID: 37779821 PMCID: PMC10540045 DOI: 10.1016/j.ohx.2023.e00469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 02/22/2023] [Accepted: 08/24/2023] [Indexed: 10/03/2023]
Abstract
A low-cost ($120 NZD, $75 USD), low-power (1-year battery life), portable, and programmable syringe pump design is presented, which offers an alternative to high-cost commercial devices with limited battery life. Contrary to typical motor-driven syringe pumps, the design utilizes a compression spring coupled with a clockwork escapement mechanism to advance the syringe plunger. Full control over flow-rate and discrete (bolus) deliveries is achieved through actuation of a clockwork escapement using programmable, low-power electronics. The escapement mechanism allows the syringe plunger to advance a fixed linear distance, delivering a dose size of 0.001 ml in the configuration presented. The modular pump assembly is easily reconfigured for different applications by interchanging components to alter the minimum dose size. Testing to IEC 60601-2-24(2012), the average error of the clockwork syringe pump was 8.0%, 4.0%, and 1.9% for 0.001 ml, 0.002 ml, and 0.01 ml volumes, respectively. An overall mean error of 1.0% was recorded for a flow-rate of 0.01 ml h-1. Compared to a commercial insulin pump, the clockwork pump demonstrated reduced variability but greater average error due to consistent over-delivery. Further development of the design and/or manufacture should yield a device with similar performance to a commercial pump.
Collapse
|
11
|
Automated evaluation of typical patient-ventilator asynchronies based on lung hysteretic responses. Biomed Eng Online 2023; 22:102. [PMID: 37875890 PMCID: PMC10598979 DOI: 10.1186/s12938-023-01165-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 10/16/2023] [Indexed: 10/26/2023] Open
Abstract
BACKGROUND Patient-ventilator asynchrony is common during mechanical ventilation (MV) in intensive care unit (ICU), leading to worse MV care outcome. Identification of asynchrony is critical for optimizing MV settings to reduce or eliminate asynchrony, whilst current clinical visual inspection of all typical types of asynchronous breaths is difficult and inefficient. Patient asynchronies create a unique pattern of distortions in hysteresis respiratory behaviours presented in pressure-volume (PV) loop. METHODS Identification method based on hysteretic lung mechanics and hysteresis loop analysis is proposed to delineate the resulted changes of lung mechanics in PV loop during asynchronous breathing, offering detection of both its incidence and 7 major types. Performance is tested against clinical patient data with comparison to visual inspection conducted by clinical doctors. RESULTS The identification sensitivity and specificity of 11 patients with 500 breaths for each patient are above 89.5% and 96.8% for all 7 types, respectively. The average sensitivity and specificity across all cases are 94.6% and 99.3%, indicating a very good accuracy. The comparison of statistical analysis between identification and human inspection yields the essential same clinical judgement on patient asynchrony status for each patient, potentially leading to the same clinical decision for setting adjustment. CONCLUSIONS The overall results validate the accuracy and robustness of the identification method for a bedside monitoring, as well as its ability to provide a quantified metric for clinical decision of ventilator setting. Hence, the method shows its potential to assist a more consistent and objective assessment of asynchrony without undermining the efficacy of the current clinical practice.
Collapse
|
12
|
Virtual patient with temporal evolution for mechanical ventilation trial studies: A stochastic model approach. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 240:107728. [PMID: 37531693 DOI: 10.1016/j.cmpb.2023.107728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 06/27/2023] [Accepted: 07/19/2023] [Indexed: 08/04/2023]
Abstract
BACKGROUND AND OBJECTIVE Healthcare datasets are plagued by issues of data scarcity and class imbalance. Clinically validated virtual patient (VP) models can provide accurate in-silico representations of real patients and thus a means for synthetic data generation in hospital critical care settings. This research presents a realistic, time-varying mechanically ventilated respiratory failure VP profile synthesised using a stochastic model. METHODS A stochastic model was developed using respiratory elastance (Ers) data from two clinical cohorts and averaged over 30-minute time intervals. The stochastic model was used to generate future Ers data based on current Ers values with added normally distributed random noise. Self-validation of the VPs was performed via Monte Carlo simulation and retrospective Ers profile fitting. A stochastic VP cohort of temporal Ers evolution was synthesised and then compared to an independent retrospective patient cohort data in a virtual trial across several measured patient responses, where similarity of profiles validates the realism of stochastic model generated VP profiles. RESULTS A total of 120,000 3-hour VPs for pressure control (PC) and volume control (VC) ventilation modes are generated using stochastic simulation. Optimisation of the stochastic simulation process yields an ideal noise percentage of 5-10% and simulation iteration of 200,000 iterations, allowing the simulation of a realistic and diverse set of Ers profiles. Results of self-validation show the retrospective Ers profiles were able to be recreated accurately with a mean squared error of only 0.099 [0.009-0.790]% for the PC cohort and 0.051 [0.030-0.126]% for the VC cohort. A virtual trial demonstrates the ability of the stochastic VP cohort to capture Ers trends within and beyond the retrospective patient cohort providing cohort-level validation. CONCLUSION VPs capable of temporal evolution demonstrate feasibility for use in designing, developing, and optimising bedside MV guidance protocols through in-silico simulation and validation. Overall, the temporal VPs developed using stochastic simulation alleviate the need for lengthy, resource intensive, high cost clinical trials, while facilitating statistically robust virtual trials, ultimately leading to improved patient care and outcomes in mechanical ventilation.
Collapse
|
13
|
Classification-based deep neural network vs mixture density network models for insulin sensitivity prediction problem. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 240:107633. [PMID: 37343375 DOI: 10.1016/j.cmpb.2023.107633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 05/21/2023] [Accepted: 05/29/2023] [Indexed: 06/23/2023]
Abstract
Model-based glycemic control (GC) protocols are used to treat stress-induced hyperglycaemia in intensive care units (ICUs). The STAR (Stochastic-TARgeted) glycemic control protocol - used in clinical practice in several ICUs in New Zealand, Hungary, Belgium, and Malaysia - is a model-based GC protocol using a patient-specific, model-based insulin sensitivity to describe the patient's actual state. Two neural network based methods are defined in this study to predict the patient's insulin sensitivity parameter: a classification deep neural network and a Mixture Density Network based method. Treatment data from three different patient cohorts are used to train the network models. Accuracy of neural network predictions are compared with the current model- based predictions used to guide care. The prediction accuracy was found to be the same or better than the reference. The authors suggest that these methods may be a promising alternative in model-based clinical treatment for patient state prediction. Still, more research is needed to validate these findings, including in-silico simulations and clinical validation trials.
Collapse
|
14
|
Harnessing Wearable Devices for Emotional Intelligence: Therapeutic Applications in Digital Health. SENSORS (BASEL, SWITZERLAND) 2023; 23:8092. [PMID: 37836923 PMCID: PMC10575398 DOI: 10.3390/s23198092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Revised: 09/25/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023]
Abstract
Emotional intelligence strives to bridge the gap between human and machine interactions. The application of such systems varies and is becoming more prominent as healthcare services seek to provide more efficient care by utilizing smart digital health apps. One application in digital health is the incorporation of emotion recognition systems as a tool for therapeutic interventions. To this end, a system is designed to collect and analyze physiological signal data, such as electrodermal activity (EDA) and electrocardiogram (ECG), from smart wearable devices. The data are collected from different subjects of varying ages taking part in a study on emotion induction methods. The obtained signals are processed to identify stimulus trigger instances and classify the different reaction stages, as well as arousal strength, using signal processing and machine learning techniques. The reaction stages are identified using a support vector machine algorithm, while the arousal strength is classified using the ResNet50 network architecture. The findings indicate that the EDA signal effectively identifies the emotional trigger, registering a root mean squared error (RMSE) of 0.9871. The features collected from the ECG signal show efficient emotion detection with 94.19% accuracy. However, arousal strength classification is only able to reach 60.37% accuracy on the given dataset. The proposed system effectively detects emotional reactions and can categorize their arousal strength in response to specific stimuli. Such a system could be integrated into therapeutic settings to monitor patients' emotional responses during therapy sessions. This real-time feedback can guide therapists in adjusting their strategies or interventions.
Collapse
|
15
|
Airflow and dynamic circumference of abdomen and thorax for adults at varied continuous positive airway pressure ventilation settings and breath rates. Sci Data 2023; 10:481. [PMID: 37481681 PMCID: PMC10363111 DOI: 10.1038/s41597-023-02326-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 06/22/2023] [Indexed: 07/24/2023] Open
Abstract
Continuous positive airway pressure (CPAP) ventilation is a commonly prescribed respiratory therapy providing positive end-expiratory pressure (PEEP) to assist breathing and prevent airway collapse. Setting PEEP is highly debated and it is thus primarily titrated based on symptoms of excessive or insufficient support. However, titration periods are clinician intensive and can result in barotrauma or under-oxygenation during the process. Developing model-based methods to more efficiently personalise CPAP therapy based on patient-specific response requires clinical data of lung/CPAP interactions. To this end, a trial was conducted to establish a dataset of healthy subjects lung/CPAP interaction. Pressure, flow, and tidal volume were recorded alongside secondary measures of dynamic chest and abdominal circumference, to better validate model outcomes and assess breathing modes, muscular recruitment, and effort. N = 30 subjects (15 male; 15 female) were included. Self-reported asthmatics and smokers/vapers were included, offering a preliminary assessment of any potential differences in response to CPAP from lung stiffness changes in these scenarios. Additional demographics associated with lung function (sex, age, height, and weight) were also recorded.
Collapse
|
16
|
Track cycling sprint sex differences using power data. PeerJ 2023; 11:e15671. [PMID: 37456896 PMCID: PMC10340095 DOI: 10.7717/peerj.15671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 06/09/2023] [Indexed: 07/18/2023] Open
Abstract
Objectives Currently, there are no data on sex differences in the power profiles in sprint track cycling. This cross-section study analyses retrospective data of female and male track sprint cyclists for sex differences. We hypothesized that women would exhibit lower peak power to weight than men, as well as demonstrate a different distribution of power durations related to sprint cycling performance. Design We used training, testing, and racing data from a publicly available online depository (www.strava.com), for 29 track sprint cyclists (eight women providing 18 datasets, and 21 men providing 54 datasets) to create sex-specific profiles. R2 was used to describe model quality, and regression indices are used to compare watts per kilogram (W/kg) for each duration for both sexes against a 1:1 relationship expected for 15-s:15-s W/kg. Results We confirmed our sample were sprint cyclists, displaying higher peak and competition power than track endurance cyclists. All power profiles showed a high model quality (R2 ≥ 0.77). Regression indices for both sexes were similar for all durations, suggesting similar peak power and similar relationship between peak power and endurance level for both men and women (rejecting our hypothesis). The value of R2 for the female sprinters showed greater variation suggesting greater differences within female sprint cyclists. Conclusion The main finding shows female sprint cyclists in this study have very similar relationships between peak power and endurance power as men. Higher variation in W/kg for women in this study than men, within these strong relationships, indicates women in this study, had greater inter-athlete variability, and may thus require more personalised training. Future work needs to be performed with larger samples, and at different levels to optimize these recommendations.
Collapse
|
17
|
Investigation of Narrow-band NIR LED Spectral Response Towards a Non-invasive Glucose Sensor. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083317 DOI: 10.1109/embc40787.2023.10340828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Spectroscopy is utilised extensively in medical sensing technology. Typically, hand-held spectroscopy equipment uses miniature narrow-band light emitting diodes (LEDs) and photodiodes to emit and detect light, respectively. Photodiodes typically absorb light across a wide spectra so measurements can be corrupted by surrounding light. LEDs in the visible spectrum have a narrower spectral response and can be used in place of a traditional photodiode. However, the absorption characteristics of near infrared (NIR) spectrum LEDs is unknown. A discrete, low-cost spectrophotometer was designed to assess spectral response for 8 narrow band NIR LEDs. The normalised and raw spectral response determined the optimum detector for 1050 nm - 1300 nm is the 1450 nm LED, and the optimum detector for 1450 nm - 1650 nm emissions is the 1650 nm LED.Clinical relevance - Understanding the spectral response of narrow-band LEDs in the NIR spectrum will aid development of NIR hand-held spectroscopy medical devices.
Collapse
|
18
|
Physical Artificial Arterial Pulse System for Development and Testing of PPG-Based Sensors. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083220 DOI: 10.1109/embc40787.2023.10340156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
A physical system to generate a PPG-mimicking signal was designed and validated using everyday low-cost components to aid in medical sensor design. The pulse waveform was created by driving a working fluid into a silicone tube and changing the pressure within it. The corresponding waveform mimics a PPG signal through an artery, is adaptable, and repeatable. The working fluid is interchangeable allowing for change of blood analyte concentrations for development and testing of PPG-based sensors. The system was validated by black ink water compared to water and air compared to water testing to confirm optical transparency of the tube. The produced PPG signal, pulse rate and pressure change were compared to that seen in subjects. Optical transparency for 660 nm - 1550 nm wavelengths of light was validated with the signal, pulse rate and total compliance matching subject data. Thus, the system can mimic arterial pulses, creating a valid PPG signal that can be detected by PPG-based sensors.Clinical Relevance- Provides a low-cost, adaptable, physical PPG signal generator for research and development of optical medical sensor technologies.
Collapse
|
19
|
Diabetes Technology Meeting 2022. J Diabetes Sci Technol 2023; 17:1085-1120. [PMID: 36704821 PMCID: PMC10347991 DOI: 10.1177/19322968221148743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Diabetes Technology Society hosted its annual Diabetes Technology Meeting from November 3 to November 5, 2022. Meeting topics included (1) the measurement of glucose, insulin, and ketones; (2) virtual diabetes care; (3) metrics for managing diabetes and predicting outcomes; (4) integration of continuous glucose monitor data into the electronic health record; (5) regulation of diabetes technology; (6) digital health to nudge behavior; (7) estimating carbohydrates; (8) fully automated insulin delivery systems; (9) hypoglycemia; (10) novel insulins; (11) insulin delivery; (12) on-body sensors; (13) continuous glucose monitoring; (14) diabetic foot ulcers; (15) the environmental impact of diabetes technology; and (16) spinal cord stimulation for painful diabetic neuropathy. A live demonstration of a device that can allow for the recycling of used insulin pens was also presented.
Collapse
|
20
|
Power-duration relationship comparison in competition sprint cyclists from 1-s to 20-min. Sprint performance is more than just peak power. PLoS One 2023; 18:e0280658. [PMID: 37235558 DOI: 10.1371/journal.pone.0280658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Accepted: 05/14/2023] [Indexed: 05/28/2023] Open
Abstract
Current convention place peak power as the main determinant of sprint cycling performance. This study challenges that notion and compares two common durations of sprint cycling performance with not only peak power, but power out to 20-min. There is also a belief where maximal efforts of longer durations will be detrimental to sprint cycling performance. 56 data sets from 27 cyclists (21 male, 6 female) provided maximal power for durations from 1-s to 20-min. Peak power values are compared to assess the strength of correlation (R2), and any relationship (slope) across every level. R2 between 15-s- 30-s power and durations from 1-s to 20-min remained high (R2 ≥ 0.83). Despite current assumptions around 1-s power, our data shows this relationship is stronger around competition durations, and 1-s power also still shared strong relationships with longer durations out to 20-min. Slopes for relationships at shorter durations were closer to a 1:1 relationship than longer durations, but closer to long-duration slopes than to a 1:1 line. The present analyses contradicts both well-accepted hypotheses that peak power is the main driver of sprint cycling performance and that maximal efforts of longer durations out to 20-min will hinder sprint cycling. This study shows the importance and potential of training durations from 1-s to 20-min over a preparation period to improve competition sprint cycling performance.
Collapse
|
21
|
Optimization of identifying insulinaemic pharmacokinetic parameters using artificial neural network. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 236:107566. [PMID: 37186981 DOI: 10.1016/j.cmpb.2023.107566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 04/09/2023] [Accepted: 04/21/2023] [Indexed: 05/17/2023]
Abstract
BACKGROUND AND OBJECTIVE The identification of insulinaemic pharmacokinetic parameters using the least-squares criterion approach is easily influenced by outlying data due to its sensitivity. Furthermore, the least-squares criterion has a tendency to overfit and produce incorrect results. Hence, this research proposes an alternative approach using the artificial neural network (ANN) with two hidden layers to optimize the identifying of insulinaemic pharmacokinetic parameters. The ANN is selected for its ability to avoid overfitting parameters and its faster speed in processing data. METHODS 18 voluntarily participants were recruited from the Canterbury and Otago region of New Zealand to take part in a Dynamic Insulin Sensitivity and Secretion Test (DISST) clinical trial. A total of 46 DISST data were collected. However, due to ambiguous and inconsistency, 4 data had to be removed. Analysis was done using MATLAB 2020a. RESULTS AND DISCUSSION Results show that, with 42 gathered dataset, the ANN generates higher gains, ∅P = 20.73 [12.21, 28.57] mU·L·mmol-1·min-1 and ∅D = 60.42 [26.85, 131.38] mU·L·mmol-1 as compared to the linear least square method, ∅P = 19.67 [11.81, 28.02] mU·L·mmol-1 ·min-1 and ∅D = 46.21 [7.25, 116.71] mU·L·mmol-1. The average value of the insulin sensitivity (SI) of ANN is lower with, SI = 16 × 10-4 L·mU-1 ·min-1 than the linear least square, SI = 17 × 10-4 L·mU-1 ·min-1. CONCLUSION Although the ANN analysis provided a lower SI value, the results were more dependable than the linear least square model because the ANN approach yielded a better model fitting accuracy than the linear least square method with a lower residual error of less than 5%. With the implementation of this ANN architecture, it shows that ANN able to produce minimal error during optimization process particularly when dealing with outlying data. The findings may provide extra information to clinicians, allowing them to gain a better knowledge of the heterogenous aetiology of diabetes and therapeutic intervention options.
Collapse
|
22
|
Model-based subcutaneous insulin for glycemic control of pre-term infants in the neonatal intensive care unit. Comput Biol Med 2023; 160:106808. [PMID: 37163965 DOI: 10.1016/j.compbiomed.2023.106808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/02/2023] [Accepted: 03/20/2023] [Indexed: 03/30/2023]
Abstract
Hyperglycaemia is a common problem in neonatal intensive care units (NICUs). Achieving good control can result in better outcomes for patients. However, good control is difficult, where poor control and resulting hypoglycaemia reduces outcomes and confounds results. Clinically validated models can provide good control, and subcutaneous insulin delivery can provide more options for insulin therapy for clinicians. However, this combination has only been significantly utilised in adult outpatient diabetes, but could hold benefit for treating NICU infants. This research combines a well-validated NICU metabolic model with subcutaneous insulin kinetics models to assess the feasibility of a model-based approach. Clinical data from 12 very/extremely pre-mature infants was collected for an average study duration of 10.1 days. Blood glucose, interstitial and plasma insulin, as well as subcutaneous and local insulin were modelled, and patient-specific insulin sensitivity profiles were identified for each patient. Modelling error was low, where the cohort median [IQR] mean percentage error was 0.8 [0.3 3.4] %. For external validation, insulin sensitivity was compared to previous NICU cohorts using the same metabolic model, where overall levels of insulin sensitivity were similar. Overall, the combined system model accurately captured observed glucose and insulin dynamics, showing the potential for a model-based approach to glycaemic control using subcutaneous insulin in this cohort. The results justify further model validation and clinical trial research to explore a model-based protocol.
Collapse
|
23
|
Single measurement estimation of central blood pressure using an arterial transfer function. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 229:107254. [PMID: 36459818 DOI: 10.1016/j.cmpb.2022.107254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 11/16/2022] [Accepted: 11/17/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND Central blood pressure (BP) better reflects the loading conditions on the major organs and is more closely correlated with future cardiovascular events. The increased invasiveness and risk of infection prevents the routine measurement of central BP. Arterial transfer functions can provide central BP estimates from clinically available peripheral measurements. However, current methods are either generalized, potentially lacking the ability to adapt to inter and intra subject variability, or individualized based on additional, clinically unavailable, pulse transit time measurements. This work proposes a novel, self-contained method for individualizing an arterial transfer function from a single peripheral pressure measurement, capable of accurately estimating central BP in a range of hemodynamic conditions. METHODS Pulse wave analysis of femoral BP waves was employed to formulate initial approximations of central BP and arterial inlet flow waveforms, to serve as objective functions for the identification of all model parameters. Root mean squared error (RMSE), and systolic and pulse pressure errors were assessed with respect to invasive aortic BP measurements in a seven (7) porcine endotoxin experiments. Systolic and pulse pressure errors were analysed using Bland-Altman analysis. Method accuracy is also compared with an idealized transfer function, derived using the measured aortic-femoral pulse transit time and minimizing the RMSE of model output pressure with respect to reference aortic pressure, a generalized transfer function model, and invasive femoral pressure measurements. RESULTS Mean bias and limits of agreement (95% CI) for the proposed method were 1.0(-4.6, 6.7)mmHg and -1.0(-6.6, 4.6)mmHg for systolic and pulse pressure, respectively, compared to 3.6(-0.9, 8.2)mmHg and 2.7(-1.8, 7.3)mmHg for the generalized transfer function model. Mean bias and limits of agreement for femoral pressure measurements were -6.4(-15.0, 2.3)mmHg and -9.4(-18.1, -0.8)mmHg, for systolic and pulse pressure, respectively. The pooled mean and standard deviation of the RMSE produced by the single measurement method, relative to reference aortic pressure, was 4.3(1.1)mmHg, consistent with estimates produced by the idealized transfer function, 3.9(1.2)mmHg, and improving of the generalized transfer function, 4.6(1.4)mmHg. CONCLUSIONS The proposed single measurement method provides accurate central BP estimates from routinely available peripheral pressure measurements, and nothing else. The method allows for the individualization of transfer functions on a per patient basis to better capture changes in patient condition during the progression of disease and subsequent treatment, at no additional clinical cost.
Collapse
|
24
|
Neurodevelopmental correlates of caudate volume in children born at risk of neonatal hypoglycaemia. Pediatr Res 2022; 93:1634-1641. [PMID: 36513807 DOI: 10.1038/s41390-022-02410-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 11/15/2022] [Accepted: 11/19/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND Neonatal hypoglycaemia can lead to brain damage and neurocognitive impairment. Neonatal hypoglycaemia is associated with smaller caudate volume in the mid-childhood. We investigated the relationship between neurodevelopmental outcomes and caudate volume and whether this relationship was influenced by neonatal hypoglycaemia. METHODS Children born at risk of neonatal hypoglycaemia ≥36 weeks' gestation who participated in a prospective cohort study underwent neurodevelopmental assessment (executive function, academic achievement, and emotional-behavioural regulation) and MRI at age 9-10 years. Neonatal hypoglycaemia was defined as at least one hypoglycaemic episode (blood glucose concentration <2.6 mmol/L or at least 10 min of interstitial glucose concentrations <2.6 mmol/L). Caudate volume was computed using FreeSurfer. RESULTS There were 101 children with MRI and neurodevelopmental data available, of whom 70 had experienced neonatal hypoglycaemia. Smaller caudate volume was associated with greater parent-reported emotional and behavioural difficulties, and poorer prosocial behaviour. Caudate volume was significantly associated with visual memory only in children who had not experienced neonatal hypoglycaemia (interaction p = 0.03), but there were no other significant interactions between caudate volume and neonatal hypoglycaemia. CONCLUSION Smaller caudate volume is associated with emotional behaviour difficulties in the mid-childhood. Although neonatal hypoglycaemia is associated with smaller caudate volume, this appears not to contribute to clinically relevant neurodevelopmental deficits. IMPACT At 9-10 years of age, caudate volume was inversely associated with emotional-behavioural difficulties and positively associated with prosocial behaviour but was not related to executive function or educational achievement. Previous studies have suggested that neonatal hypoglycaemia may contribute to smaller caudate volume but exposure to neonatal hypoglycaemia did not appear to influence the relationship between caudate volume and behaviour. Among children not exposed to neonatal hypoglycaemia, caudate volume was also positively associated with visual memory, but no such association was detected among those exposed to neonatal hypoglycaemia. Understanding early-life factors that affect caudate development may provide targets for improving behavioural function.
Collapse
|
25
|
Predicting mechanically ventilated patients future respiratory system elastance - A stochastic modelling approach. Comput Biol Med 2022; 151:106275. [PMID: 36375413 DOI: 10.1016/j.compbiomed.2022.106275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 10/26/2022] [Accepted: 10/30/2022] [Indexed: 11/13/2022]
Abstract
BACKGROUND AND OBJECTIVE Respiratory mechanics of mechanically ventilated patients evolve significantly with time, disease state and mechanical ventilation (MV) treatment. Existing deterministic data prediction methods fail to comprehensively describe the multiple sources of heterogeneity of biological systems. This research presents two respiratory mechanics stochastic models with increased prediction accuracy and range, offering improved clinical utility in MV treatment. METHODS Two stochastic models (SM2 and SM3) were developed using retrospective patient respiratory elastance (Ers) from two clinical cohorts which were averaged over time intervals of 10 and 30 min respectively. A stochastic model from a previous study (SM1) was used to benchmark performance. The stochastic models were clinically validated on an independent retrospective clinical cohort of 14 patients. Differences in predictive ability were evaluated using the difference in percentile lines and cumulative distribution density (CDD) curves. RESULTS Clinical validation shows all three models captured more than 98% (median) of future Ers data within the 5th - 95th percentile range. Comparisons of stochastic model percentile lines reported a maximum mean absolute percentage difference of 5.2%. The absolute differences of CDD curves were less than 0.25 in the ranges of 5 < Ers (cmH2O/L) < 85, suggesting similar predictive capabilities within this clinically relevant Ers range. CONCLUSION The new stochastic models significantly improve prediction, clinical utility, and thus feasibility for synchronisation with clinical interventions. Paired with other MV protocols, the stochastic models developed can potentially form part of decision support systems, providing guided, personalised, and safe MV treatment.
Collapse
|
26
|
Modelling patient specific cardiopulmonary interactions. Comput Biol Med 2022; 151:106235. [PMID: 36334361 DOI: 10.1016/j.compbiomed.2022.106235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/19/2022] [Accepted: 10/22/2022] [Indexed: 12/27/2022]
Abstract
Mechanical ventilation is well known for having detrimental effects on the cardiovascular system, particularly when using high positive end-expiratory pressure. High positive end-expiratory pressure levels cause a decrease in stroke volume, which, under normal conditions, usually bring about a decrease in stressed blood volume. Stressed blood volume, defined as the total pressure generating volume of the cardiovascular system, has been shown to be a potential index of fluid responsiveness, making it a potentially important diagnostic tool. Generally, respiratory and haemodynamic care are provided independently of one another. However, that positive end-expiratory pressure alters both stroke volume and stressed blood volume suggests both the pulmonary and cardiovascular state should be conjointly optimised and used to guide positive end-expiratory pressure. However, the complex and patient-specific nature of cardiopulmonary interactions which occur during mechanical ventilation presents a challenge for accurate modelling of respiratory and cardiovascular interactions required to better optimise care. Previous models attempting to incorporate cardiopulmonary interactions have suffered from poor reliability at higher PEEP levels, largely due to an exaggerated effect of intrathoracic pressure on the cardiovascular system. A new parameter, alpha, is added to a previously validated cardiopulmonary model, to modulate the percentage of intrathoracic pressure applied to the vena cava and left ventricle. The new parameter aims to increase reliability under high PEEP conditions as well as provide a patient specific solution to modelling cardiopulmonary interactions. The results from the identified optimal alpha are compared to the original model to investigate how this new parameter may be used to create a more patient-specific cardiopulmonary model, which would be better suited for guidance of care in the ICU.
Collapse
|
27
|
Breast cancer diagnosis using frequency decomposition of surface motion of actuated breast tissue. Front Oncol 2022; 12:969530. [DOI: 10.3389/fonc.2022.969530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 10/12/2022] [Indexed: 11/06/2022] Open
Abstract
This paper presents a computationally simple diagnostic algorithm for breast cancer using a non-invasive Digital Image Elasto Tomography (DIET) system. N=14 women (28 breasts, 13 cancerous) underwent a clinical trial using the DIET system following mammography diagnosis. The screening involves steady state sinusoidal vibrations applied to the free hanging breast with cameras used to capture tissue motion. Image reconstruction methods provide surface displacement data for approximately 14,000 reference points on the breast surface. The breast surface was segmented into four radial and four vertical segments. Frequency decomposition of reference point motion in each segment were compared. Segments on the same vertical band were hypothesised to have similar frequency content in healthy breasts, with significant differences indicating a tumor, based on the stiffness dependence of frequency and tumors being 4~10 times stiffer than healthy tissue. Twelve breast configurations were used to test robustness of the method. Optimal breast configuration for the 26 breasts analysed (13 cancerous, 13 healthy) resulted in 85% sensitivity and 77% specificity. Combining two opposite configurations resulted in correct diagnosis of all cancerous breasts with 100% sensitivity and 69% specificity. Bootstrapping was used to fit a smooth receiver operator characteristic (ROC) curve to compare breast configuration performance with optimal area under the curve (AUC) of 0.85. Diagnostic results show diagnostic accuracy is comparable or better than mammography, with the added benefits of DIET screening, including portability, non-invasive screening, and no breast compression, with potential to increase screening participation and equity, improving outcomes for women.
Collapse
|
28
|
Low-cost structured light imaging of regional volume changes for use in assessing mechanical ventilation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107176. [PMID: 36228494 DOI: 10.1016/j.cmpb.2022.107176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 09/21/2022] [Accepted: 10/04/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND Optimal setting of mechanical ventilators is critical for improving outcomes. Accurate, predictive lung mechanics models are effective in optimizing MV settings, but only at a global level as they cannot estimate regional lung volume ventilation to assess the potential of local distension or under-ventilation. This study presents a low-cost structured light system for non-contact high resolution chest motion measurement to estimate regional lung volume changes. METHODS The system consists of a structured light projector and two cameras. A new pattern is designed to extract motion from sub-regions of the chest surface, and an efficient feature is proposed to provide a fast and accurate correspondence matching between two views. Reconstruction of 3D surface points is based on the matched points and stereo method. Asymmetric distribution of tidal volume into left and right lungs is estimated based on reconstructed regional chest expansion. A proof-of-concept experiment using a dummy model and two test lungs connected to a ventilator to provide differential chest expansion is conducted under tidal volumes of 400 ml, 500 ml and 600 ml, with results compared to the widely-used SURF and ORB methods. RESULTS Compared to the SURF and ORB methods, the proposed method is more computationally efficient with ∼40% less computational time cost, and higher accuracy for dense point correspondence. Finally, the proposed method estimated the region lung volumes with the maximum error of 8 ml under 600 ml tidal volume, indicating a good accuracy. CONCLUSIONS Surface reconstruction results in a proof-of-concept experiment with differential chest expansion show good performance for the proposed pattern and method in extracting the key information for regional chest expansion. The proposed method is generalizable, with potential for use in other applications.
Collapse
|
29
|
Virtual patient framework for the testing of mechanical ventilation airway pressure and flow settings protocol. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107146. [PMID: 36191352 DOI: 10.1016/j.cmpb.2022.107146] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 09/17/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND AND OBJECTIVE Model-based and personalised decision support systems are emerging to guide mechanical ventilation (MV) treatment for respiratory failure patients. However, model-based treatments require resource-intensive clinical trials prior to implementation. This research presents a framework for generating virtual patients for testing model-based decision support, and direct use in MV treatment. METHODS The virtual MV patient framework consists of 3 stages: 1) Virtual patient generation, 2) Patient-level validation, and 3) Virtual clinical trials. The virtual patients are generated from retrospective MV patient data using a clinically validated respiratory mechanics model whose respiratory parameters (respiratory elastance and resistance) capture patient-specific pulmonary conditions and responses to MV care over time. Patient-level validation compares the predicted responses from the virtual patient to their retrospective results for clinically implemented MV settings and changes to care. Patient-level validated virtual patients create a platform to conduct virtual trials, where the safety of closed-loop model-based protocols can be evaluated. RESULTS This research creates and presents a virtual patient platform of 100 virtual patients generated from retrospective data. Patient-level validation reported median errors of 3.26% for volume-control and 6.80% for pressure-control ventilation mode. A virtual trial on a model-based protocol demonstrates the potential efficacy of using virtual patients for prospective evaluation and testing of the protocol. CONCLUSION The virtual patient framework shows the potential to safely and rapidly design, develop, and optimise new model-based MV decision support systems and protocols using clinically validated models and computer simulation, which could ultimately improve patient care and outcomes in MV.
Collapse
|
30
|
CAREDAQ: Data acquisition device for mechanical ventilation waveform monitoring. HARDWAREX 2022; 12:e00358. [PMID: 36117541 PMCID: PMC9474567 DOI: 10.1016/j.ohx.2022.e00358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Revised: 09/01/2022] [Accepted: 09/05/2022] [Indexed: 06/15/2023]
Abstract
Mechanical ventilation (MV) provides respiratory support for critically ill patients in the intensive care unit (ICU). Waveform data output by the ventilator provides valuable physiological and diagnostic information. However, existing systems do not provide full access to this information nor allow for real-time, non-invasive data collection. Therefore, large amounts of data are lost and analysis is limited to short samples of breathing cycles. This study presents a data acquisition device for acquiring and monitoring patient ventilation waveform data. Acquired data can be exported to other systems, allowing users to further analyse data and develop further clinically useful parameters. These parameters, together with other ventilatory information, can help personalise and guide MV treatment. The device is designed to be easily replicable, low-cost, and scalable according to the number of patient beds. Validation was carried out by assessing system performance and stability over prolonged periods of 7 days of continuous use. The device provides a platform for future integration of machine-learning or model-based modules, potentially allowing real-time, proactive, patient-specific MV guidance and decision support to improve the quality and productivity of care and outcomes.
Collapse
|
31
|
Abstract
In this report we present a design for an open source low cost insulin pump. The pump has been designed to provide an alternative to commercially available pumps costing upwards of US$6500, making them inaccessible to many. The hardware described in this article can be produced for a materials cost of US$89.85. Compared to other devices on the market, the design presented has the obvious advantage of being low cost, but is also highly customisable as it is run using open source software. The device is housed in a case of size 85 mm x 55 mm x 25 mm making it small enough to fit in a pocket, and equivalent to other devices on the market. The device is designed to work with insulin cartridges currently available on the market. Power is provided through the use of AAA batteries, and the pump is able to be recharged through a USB mini port. The accuracy of the pump has been tested and compared to data obtained from an in-warranty commercial insulin pump model using an identical testing methodology, with the ultra-low-cost pump performing similarly to the commercial model. The system can be readily extended to be controlled from external bluetooth or wired mobile devices using their built in security, offloading computation from the device and onto a phone.
Collapse
|
32
|
Respiratory bi-directional pressure and flow data collection device with thoracic and abdominal circumferential monitoring. HARDWAREX 2022; 12:e00354. [PMID: 36082149 PMCID: PMC9445388 DOI: 10.1016/j.ohx.2022.e00354] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/07/2022] [Accepted: 08/20/2022] [Indexed: 06/15/2023]
Abstract
Non-invasive pressure and flow data from Venturi-based sensors can be used with validated models to identify patient-specific lung mechanics. To validate applied respiratory models a secondary measurement is required. Rotary encoder-based tape measures were designed to capture change in circumference of a subject's thorax and diaphragm. Circumferential changes can be correlated to measured or modelled change in lung volume and associated muscular recruitment measures (patient work of breathing). Hence, these simple measurement devices can expedite respiratory research, by adding low-cost, accessible, and clinically useful measurements.
Collapse
|
33
|
The Effects of Additional Local-Mixing Compartments in the DISST Model-Based Assessment of Insulin Sensitivity. J Diabetes Sci Technol 2022; 16:1196-1207. [PMID: 34116618 PMCID: PMC9445349 DOI: 10.1177/19322968211021602] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The identification of insulin sensitivity in glycemic modelling can be heavily obstructed by the presence of outlying data or unmodelled effects. The effect of data indicative of local mixing is especially problematic with models assuming rapid mixing of compartments. Methods such as manual removal of data and outlier detection methods have been used to improve parameter ID in these cases, but modelling data with more compartments is another potential approach. METHODS This research compares a mixing model with local depot site compartments with an existing, clinically validated insulin sensitivity test model. The Levenberg-Marquardt (LM) parameter identification method was implemented alongside a modified version (aLM) capable of operator-independent omission of outlier data in accordance with the 3 standard deviation rule. Three cases were tested: LM where data points suspected to be affected by incomplete mixing at the depot site were removed, aLM, and LM with the more complex mixing model. RESULTS While insulin parameters identified in the mixing model differed greatly from those in the DISST model, there were strong Spearman correlations of approximately 0.93 for the insulin sensitivity values identified across all 3 methods. The 2 models also showed comparable identification stability in insulin sensitivity estimation through a Monte Carlo analysis. However, the mixing model required modifications to the identification process to improve convergence, and still failed to converge to feasible parameters on 5 of the 212 trials. CONCLUSIONS The mixing compartment model effectively captured the dynamics of mixing behavior, but with no significant improvement in insulin sensitivity identification.
Collapse
|
34
|
Estimating Enhanced Endogenous Glucose Production in Intensive Care Unit Patients with Severe Insulin Resistance. J Diabetes Sci Technol 2022; 16:1208-1219. [PMID: 34078114 PMCID: PMC9445352 DOI: 10.1177/19322968211018260] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Critically ill ICU patients frequently experience acute insulin resistance and increased endogenous glucose production, manifesting as stress-induced hyperglycemia and hyperinsulinemia. STAR (Stochastic TARgeted) is a glycemic control protocol, which directly manages inter- and intra- patient variability using model-based insulin sensitivity (SI). The model behind STAR assumes a population constant for endogenous glucose production (EGP), which is not otherwise identifiable. OBJECTIVE This study analyses the effect of estimating EGP for ICU patients with very low SI (severe insulin resistance) and its impact on identified, model-based insulin sensitivity identification, modeling accuracy, and model-based glycemic clinical control. METHODS Using clinical data from 717 STAR patients in 3 independent cohorts (Hungary, New Zealand, and Malaysia), insulin sensitivity, time of insulin resistance, and EGP values are analyzed. A method is presented to estimate EGP in the presence of non-physiologically low SI. Performance is assessed via model accuracy. RESULTS Results show 22%-62% of patients experience 1+ episodes of severe insulin resistance, representing 0.87%-9.00% of hours. Episodes primarily occur in the first 24 h, matching clinical expectations. The Malaysian cohort is most affected. In this subset of hours, constant model-based EGP values can bias identified SI and increase blood glucose (BG) fitting error. Using the EGP estimation method presented in these constrained hours significantly reduced BG fitting errors. CONCLUSIONS Patients early in ICU stay may have significantly increased EGP. Increasing modeled EGP in model-based glycemic control can improve control accuracy in these hours. The results provide new insight into the frequency and level of significantly increased EGP in critical illness.
Collapse
|
35
|
Oral diazoxide versus placebo for severe or recurrent neonatal hypoglycaemia: Neonatal Glucose Care Optimisation (NeoGluCO) study - a randomised controlled trial. BMJ Open 2022; 12:e059452. [PMID: 35977769 PMCID: PMC9389093 DOI: 10.1136/bmjopen-2021-059452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
INTRODUCTION Infants with severe or recurrent transitional hypoglycaemia continue to have high rates of adverse neurological outcomes and new treatment approaches are needed that target the underlying pathophysiology. Diazoxide is one such treatment that acts on the pancreatic β-cell in a dose-dependent manner to decrease insulin secretion. METHODS AND ANALYSIS Phase IIB, double-blind, two-arm, parallel, randomised trial of diazoxide versus placebo in neonates ≥35 weeks' gestation for treatment of severe (blood glucose concentration (BGC)<1.2 mmol/L or BGC 1.2 to <2.0 mmol/L despite two doses of buccal dextrose gel and feeding in a single episode) or recurrent (≥3 episodes <2.6 mmol/L in 48 hours) transitional hypoglycaemia. Infants are loaded with diazoxide 5 mg/kg orally and then commenced on a maintenance dose of 1.5 mg/kg every 12 hours, or an equal volume of placebo. The intervention is titrated from the third maintenance dose by protocol to target BGC in the range of 2.6-5.4 mmol/L. The primary outcome is time to resolution of hypoglycaemia, defined as the first point at which the following criteria are met concurrently for ≥24 hours: no intravenous fluids, enteral bolus feeding and normoglycaemia. Groups will be compared for the primary outcome using Cox's proportional hazard regression analysis, expressed as adjusted HR with a 95% CI. ETHICS AND DISSEMINATION This trial has been approved by the Health and Disability Ethics Committees of New Zealand (19CEN189). Findings will be disseminated in peer-reviewed journals, to clinicians and researchers at local and international conferences and to the public. TRIAL REGISTRATION NUMBER ACTRN12620000129987.
Collapse
|
36
|
CPAP pressure and flow data at 2 positive pressure levels and multiple controlled breathing rates from a trial of 30 adults. BMC Res Notes 2022; 15:257. [PMID: 35842701 PMCID: PMC9288698 DOI: 10.1186/s13104-022-06133-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 06/21/2022] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVES A unique dataset of airway flow/pressure from healthy subjects on Continuous Positive Airway Pressure (CPAP) ventilation was collected. This data can be used to develop or validate models of pulmonary mechanics, and/or to develop methods to identify patient-specific parameters which cannot be measured non-invasively, during CPAP therapy. These models and values, particularly if available breath-to-breath in real-time, could assist clinicians in the prescription or optimisation of CPAP therapy, including optimising PEEP settings. DATA DESCRIPTION Data was obtained from 30 subjects for model-based identification of patient-specific lung mechanics using a specially designed venturi sensor system comprising an array of differential and gauge pressure sensors. Relevant medical information was collected using a questionnaire, including: sex; age; weight; height; smoking history; and history of asthma. Subjects were tasked with breathing at five different rates (including passive), matched to an online pacing sound and video, at two different levels of PEEP (4 and 7 cmH2O) for between 50 and 180 s. Each data set comprises ~ 17 breaths of data, including rest periods between breathing rates and CPAP levels.
Collapse
|
37
|
Abstract
OBJECTIVE Model-based metabolic tests require accurate identification of subject-specific parameters from measured assays. Insulin assays are used to identify insulin kinetics parameters, such as general and first-pass hepatic clearances. This study assesses the impact of intravenous insulin boluses on parameter identification precision. METHOD Insulin and C-peptide data from two intravenous glucose tolerance test (IVGTT) trials of healthy adults (N = 10 × 2; denoted A and B), with (A) and without (B) insulin modification, were used to identify insulin kinetics parameters using a grid search. Monte Carlo analysis (N = 1000) quantifies variation in simulation error for insulin assay errors of 5%. A region of parameter values around the optimum was identified whose errors are within variation due to assay error. A smaller optimal region indicates more precise practical identifiability. Trial results were compared to assess identifiability and precision. RESULTS Trial B, without insulin modification, has optimal parameter regions 4.7 times larger on average than Trial A, with 1-U insulin bolus modification. Ranges of optimal parameter values between trials A and B increase from 0.04 to 0.12 min-1 for hepatic clearance and from 0.07 to 0.14 for first-pass clearance on average. Trial B's optimal values frequently lie outside physiological ranges, further indicating lack of distinct identifiability. CONCLUSIONS A small 1-U insulin bolus improves identification of hepatic clearance parameters by providing a smaller region of optimal parameter values. Adding an insulin bolus in metabolic tests can significantly improve identifiability and outcome test precision. Assay errors necessitate insulin modification in clinical tests to ensure identifiability and precision.
Collapse
|
38
|
Physiological trend analysis of a novel cardio-pulmonary model during a preload reduction manoeuvre. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 220:106819. [PMID: 35461125 DOI: 10.1016/j.cmpb.2022.106819] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 04/13/2022] [Accepted: 04/14/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Mechanical ventilation causes adverse effects on the cardiovascular system. However, the exact nature of the effects on haemodynamic parameters is not fully understood. A recently developed cardio-vascular system model which incorporates cardio-pulmonary interactions is compared to the original 3-chamber cardiovascular model to investigate the exact effects of mechanical ventilation on haemodynamic parameters and to assess the trade-off of model complexity and model reliability between the 2 models. METHODS Both the cardio-pulmonary and three chamber models are used to identify cardiovascular system parameters from aortic pressure, left ventricular volume, airway flow and airway pressure measurements from 4 pigs during a preload reduction manoeuvre. Outputs and parameter estimations from both models are contrasted to assess the relative performance of each model and to further investigate the effects of mechanical ventilation on haemodynamic parameters. RESULTS Both models tracked measurements accurately as expected. There was no identifiable increase in error from the added complexity of the cardio-pulmonary model, with both models having a mean average error below 0.5% for all pigs. Identified left ventricle and vena cava elastances of the 3-chamber model was found to diverge exponentially with PEEP from identified left ventricle and vena cava elastances of the cardio-pulmonary model. The r2 of the fit for each pig ranged from 0.888 to 0.998 for left ventricle elastance divergence and from 0.905 to 0.999 for vena cava elastance divergence. All other identified parameters showed no significant difference between models. CONCLUSIONS Despite the increase in model complexity, there was no loss in the cardio-pulmonary model's ability to accurately estimate haemodynamic parameters and reproduce system dynamics. Furthermore, the cardio-pulmonary model was able to demonstrate how mechanical ventilation affected parameter estimations as PEEP was increased. The 3-chamber model was shown to produce parameter estimations which diverged exponentially with PEEP, while the cardiopulmonary model estimations remained more stable, suggesting its ability to produce more physiologically accurate parameter estimations under higher PEEP conditions.
Collapse
|
39
|
Estimating the incidence of spontaneous breathing effort of mechanically ventilated patients using a non-linear auto regressive (NARX) model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 220:106835. [PMID: 35512627 PMCID: PMC9754157 DOI: 10.1016/j.cmpb.2022.106835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 04/04/2022] [Accepted: 04/21/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Mechanical ventilation (MV) provides breathing support for acute respiratory distress syndrome (ARDS) patients in the intensive care unit, but is difficult to optimize. Too much, or too little of pressure or volume support can cause further ventilator-induced lung injury, increasing length of MV, cost and mortality. Patient-specific respiratory mechanics can help optimize MV settings. However, model-based estimation of respiratory mechanics is less accurate when patient exhibit un-modeled spontaneous breathing (SB) efforts on top of ventilator support. This study aims to estimate and quantify SB efforts by reconstructing the unaltered passive mechanics airway pressure using NARX model. METHODS Non-linear autoregressive (NARX) model is used to reconstruct missing airway pressure due to the presence of spontaneous breathing effort in mv patients. Then, the incidence of SB patients is estimated. The study uses a total of 10,000 breathing cycles collected from 10 ARDS patients from IIUM Hospital in Kuantan, Malaysia. In this study, there are 2 different ratios of training and validating methods. Firstly, the initial ratio used is 60:40 which indicates 600 breath cycles for training and remaining 400 breath cycles used for testing. Then, the ratio is varied using 70:30 ratio for training and testing data. RESULTS AND DISCUSSION The mean residual error between original airway pressure and reconstructed airway pressure is denoted as the magnitude of effort. The median and interquartile range of mean residual error for both ratio are 0.0557 [0.0230 - 0.0874] and 0.0534 [0.0219 - 0.0870] respectively for all patients. The results also show that Patient 2 has the highest percentage of SB incidence and Patient 10 with the lowest percentage of SB incidence which proved that NARX model is able to perform for both higher incidence of SB effort or when there is a lack of SB effort. CONCLUSION This model is able to produce the SB incidence rate based on 10% threshold. Hence, the proposed NARX model is potentially useful to estimate and identify patient-specific SB effort, which has the potential to further assist clinical decisions and optimize MV settings.
Collapse
|
40
|
Abstract
BACKGROUND The ability to measure insulin secretion from pancreatic beta cells and monitor glucose-insulin physiology is vital to current health needs. C-peptide has been used successfully as a surrogate for plasma insulin concentration. Quantifying the expected variability of modelled insulin secretion will improve confidence in model estimates. METHODS Forty-three healthy adult males of Māori or Pacific peoples ancestry living in New Zealand participated in an frequently sampled, intravenous glucose tolerance test (FS-IVGTT) with an average age of 29 years and a BMI of 33 kg/m2. A 2-compartment model framework and standardized kinetic parameters were used to estimate endogenous pancreatic insulin secretion from plasma C-peptide measurements. Monte Carlo analysis (N = 10 000) was then used to independently vary parameters within ±2 standard deviations of the mean of each variable and the 5th and 95th percentiles determined the bounds of the expected range of insulin secretion. Cumulative distribution functions (CDFs) were calculated for each subject for area under the curve (AUC) total, AUC Phase 1, and AUC Phase 2. Normalizing each AUC by the participant's median value over all N = 10 000 iterations quantifies the expected model-based variability in AUC. RESULTS Larger variation is found in subjects with a BMI > 30 kg/m2, where the interquartile range is 34.3% compared to subjects with a BMI ≤ 30 kg/m2 where the interquartile range is 24.7%. CONCLUSIONS Use of C-peptide measurements using a 2-compartment model and standardized kinetic parameters, one can expect ~±15% variation in modelled insulin secretion estimates. The variation should be considered when applying this insulin secretion estimation method to clinical diagnostic thresholds and interpretation of model-based analyses such as insulin sensitivity.
Collapse
|
41
|
Low cost circulatory pressure acquisition and fluid infusion rate measurement system for clinical research. HARDWAREX 2022; 11:e00318. [PMID: 35637841 PMCID: PMC9144005 DOI: 10.1016/j.ohx.2022.e00318] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Acquiring patient physiological waveforms is useful for studying hemodynamic management and developing medical monitoring systems. A low cost, Arduino controlled data acquisition system acquires arterial pressure waveforms (Edwards Lifesciences TruWave compatible) and measures fluid infusion rate using hanging scales. This system can be used at the same time as a clinical monitor, enabling recording of patient arterial pressure and fluid delivery for clinical research. The system is powered via a USB connection, which additionally provides serial output, aiding compatibility and customisation. A simple software user interface, developed in Python, shows outputs. Each data acquisition system, including all necessary connection cables costs ~US$90 and is multiple-use.
Collapse
|
42
|
Determining Losses in Jet Injection Subcutaneous Insulin Delivery: A Model-Based Approach. J Diabetes Sci Technol 2022:19322968221085032. [PMID: 35343255 DOI: 10.1177/19322968221085032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Accurate, safe glycemic management requires reliable delivery of insulin doses. Insulin can be delivered subcutaneously for action over a longer period of time. Needle-free jet injectors provide subcutaneous (SC) delivery without requiring needle use, but the volume of insulin absorbed varies due to losses associated with the delivery method. This study employs model-based methods to determine the expected proportion of active insulin present from a needle-free SC dose. METHODS Insulin, C-peptide, and glucose assay data from a frequently sampled insulin-modified oral glucose tolerance test trial with 2U SC insulin delivery, paired with a well-validated metabolic model, predict metabolic outcomes for N = 7 healthy adults. Subject-specific nonlinear hepatic clearance profiles are modeled over time using third-order basis splines with knots located at assay times. Hepatic clearance profiles are constrained within a physiological rate of change, and relative to plasma glucose profiles. Insulin loss proportions yielding optimal insulin predictions are then identified, quantifying delivery losses. RESULTS Optimal parameter identification suggests losses of up to 22% of the nominal 2U SC dose. The degree of loss varies between subjects and between trials on the same subject. Insulin fit accuracy improves where loss greater than 5% is identified, relative to where delivery loss is not modeled. CONCLUSIONS Modeling shows needle-free SC jet injection of a nominal dose of insulin does not necessarily provide metabolic action equivalent to total dose, and this availability significantly varies between trials. By quantifying and accounting for variability of jet injection insulin doses, better glycemic management outcomes using SC jet injection may be achieved.
Collapse
|
43
|
Abstract
IMPORTANCE Neonatal hypoglycemia is associated with increased risk of poor executive and visual-motor function, but implications for later learning are uncertain. OBJECTIVE To test the hypothesis that neonatal hypoglycemia is associated with educational performance at age 9 to 10 years. DESIGN, SETTING, AND PARTICIPANTS Prospective cohort study of moderate to late preterm and term infants born at risk of hypoglycemia. Blood and masked interstitial sensor glucose concentrations were measured for up to 7 days. Infants with hypoglycemic episodes (blood glucose concentration <47 mg/dL [2.6 mmol/L]) were treated to maintain a blood glucose concentration of at least 47 mg/dL. Six hundred fourteen infants were recruited at Waikato Hospital, Hamilton, New Zealand, in 2006-2010; 480 were assessed at age 9 to 10 years in 2016-2020. EXPOSURES Hypoglycemia was defined as at least 1 hypoglycemic event, representing the sum of nonconcurrent hypoglycemic and interstitial episodes (sensor glucose concentration <47 mg/dL for ≥10 minutes) more than 20 minutes apart. MAIN OUTCOMES AND MEASURES The primary outcome was low educational achievement, defined as performing below or well below the normative curriculum level in standardized tests of reading comprehension or mathematics. There were 47 secondary outcomes related to executive function, visual-motor function, psychosocial adaptation, and general health. RESULTS Of 587 eligible children (230 [48%] female), 480 (82%) were assessed at a mean age of 9.4 (SD, 0.3) years. Children who were and were not exposed to neonatal hypoglycemia did not significantly differ on rates of low educational achievement (138/304 [47%] vs 82/176 [48%], respectively; adjusted risk difference, -2% [95% CI, -11% to 8%]; adjusted relative risk, 0.95 [95% CI, 0.78-1.15]). Children who were exposed to neonatal hypoglycemia, compared with those not exposed, were significantly less likely to be rated by teachers as being below or well below the curriculum level for reading (68/281 [24%] vs 49/157 [31%], respectively; adjusted risk difference, -9% [95% CI, -17% to -1%]; adjusted relative risk, 0.72 [95% CI, 0.53-0.99; P = .04]). Groups were not significantly different for other secondary end points. CONCLUSIONS AND RELEVANCE Among participants at risk of neonatal hypoglycemia who were screened and treated if needed, exposure to neonatal hypoglycemia compared with no such exposure was not significantly associated with lower educational achievement in mid-childhood.
Collapse
|
44
|
Reconstructing asynchrony for mechanical ventilation using a hysteresis loop virtual patient model. Biomed Eng Online 2022; 21:16. [PMID: 35255922 PMCID: PMC8900099 DOI: 10.1186/s12938-022-00986-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Accepted: 02/21/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Patient-specific lung mechanics during mechanical ventilation (MV) can be identified from measured waveforms of fully ventilated, sedated patients. However, asynchrony due to spontaneous breathing (SB) effort can be common, altering these waveforms and reducing the accuracy of identified, model-based, and patient-specific lung mechanics. METHODS Changes in patient-specific lung elastance over a pressure-volume (PV) loop, identified using hysteresis loop analysis (HLA), are used to detect the occurrence of asynchrony and identify its type and pattern. The identified HLA parameters are then combined with a nonlinear mechanics hysteresis loop model (HLM) to extract and reconstruct ventilated waveforms unaffected by asynchronous breaths. Asynchrony magnitude can then be quantified using an energy-dissipation metric, Easyn, comparing PV loop area between model-reconstructed and original, altered asynchronous breathing cycles. Performance is evaluated using both test-lung experimental data with a known ground truth and clinical data from four patients with varying levels of asynchrony. RESULTS Root mean square errors for reconstructed PV loops are within 5% for test-lung experimental data, and 10% for over 90% of clinical data. Easyn clearly matches known asynchrony magnitude for experimental data with RMS errors < 4.1%. Clinical data performance shows 57% breaths having Easyn > 50% for Patient 1 and 13% for Patient 2. Patient 3 only presents 20% breaths with Easyn > 10%. Patient 4 has Easyn = 0 for 96% breaths showing accuracy in a case without asynchrony. CONCLUSIONS Experimental test-lung validation demonstrates the method's reconstruction accuracy and generality in controlled scenarios. Clinical validation matches direct observations of asynchrony in incidence and quantifies magnitude, including cases without asynchrony, validating its robustness and potential efficacy as a clinical real-time asynchrony monitoring tool.
Collapse
|
45
|
Stochastic integrated model-based protocol for volume-controlled ventilation setting. Biomed Eng Online 2022; 21:13. [PMID: 35148759 PMCID: PMC8832735 DOI: 10.1186/s12938-022-00981-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 01/21/2022] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND AND OBJECTIVE Mechanical ventilation (MV) is the primary form of care for respiratory failure patients. MV settings are based on general clinical guidelines, intuition, and experience. This approach is not patient-specific and patients may thus experience suboptimal, potentially harmful MV care. This study presents the Stochastic integrated VENT (SiVENT) protocol which combines model-based approaches of the VENT protocol from previous works, with stochastic modelling to take the variation of patient respiratory elastance over time into consideration. METHODS A stochastic model of Ers is integrated into the VENT protocol from previous works to develop the SiVENT protocol, to account for both intra- and inter-patient variability. A cohort of 20 virtual MV patients based on retrospective patient data are used to validate the performance of this method for volume-controlled (VC) ventilation. A performance evaluation was conducted where the SiVENT and VENT protocols were implemented in 1080 instances each to compare the two protocols and evaluate the difference in reduction of possible MV settings achieved by each. RESULTS From an initial number of 189,000 possible MV setting combinations, the VENT protocol reduced this number to a median of 10,612, achieving a reduction of 94.4% across the cohort. With the integration of the stochastic model component, the SiVENT protocol reduced this number from 189,000 to a median of 9329, achieving a reduction of 95.1% across the cohort. The SiVENT protocol reduces the number of possible combinations provided to the user by more than 1000 combinations as compared to the VENT protocol. CONCLUSIONS Adding a stochastic model component into a model-based approach to selecting MV settings improves the ability of a decision support system to recommend patient-specific MV settings. It specifically considers inter- and intra-patient variability in respiratory elastance and eliminates potentially harmful settings based on clinically recommended pressure thresholds. Clinical input and local protocols can further reduce the number of safe setting combinations. The results for the SiVENT protocol justify further investigation of its prediction accuracy and clinical validation trials.
Collapse
|
46
|
Model-based patient matching for in-parallel pressure-controlled ventilation. Biomed Eng Online 2022; 21:11. [PMID: 35139858 PMCID: PMC8826717 DOI: 10.1186/s12938-022-00983-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 01/24/2022] [Indexed: 12/03/2022] Open
Abstract
Background Surges of COVID-19 infections have led to insufficient supply of mechanical ventilators (MV), resulting in rationing of MV care. In-parallel, co-mechanical ventilation (Co-MV) of multiple patients is a potential solution. However, due to lack of testing, there is currently no means to match ventilation requirements or patients, with no guidelines to date. In this research, we have developed a model-based method for patient matching for pressure control mode MV. Methods The model-based method uses a single-compartment lung model (SCM) to simulate the resultant tidal volume of patient pairs at a set ventilation setting. If both patients meet specified safe ventilation criteria under similar ventilation settings, the actual mechanical ventilator settings for Co-MV are determined via simulation using a double-compartment lung model (DCM). This method allows clinicians to analyse Co-MV in silico, before clinical implementation. Results The proposed method demonstrates successful patient matching and MV setting in a model-based simulation as well as good discrimination to avoid mismatched patient pairs. The pairing process is based on model-based, patient-specific respiratory mechanics identified from measured data to provide useful information for guiding care. Specifically, the matching is performed via estimation of MV delivered tidal volume (mL/kg) based on patient-specific respiratory mechanics. This information can provide insights for the clinicians to evaluate the subsequent effects of Co-MV. In addition, it was also found that Co-MV patients with highly restrictive respiratory mechanics and obese patients must be performed with extra care. Conclusion This approach allows clinicians to analyse patient matching in a virtual environment without patient risk. The approach is tested in simulation, but the results justify the necessary clinical validation in human trials. Supplementary Information The online version contains supplementary material available at 10.1186/s12938-022-00983-y.
Collapse
|
47
|
Protocol conception for safe selection of mechanical ventilation settings for respiratory failure Patients. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 214:106577. [PMID: 34936946 DOI: 10.1016/j.cmpb.2021.106577] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/17/2021] [Accepted: 12/03/2021] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Mechanical ventilation is the primary form of care provided to respiratory failure patients. Limited guidelines and conflicting results from major clinical trials means selection of mechanical ventilation settings relies heavily on clinician experience and intuition. Determining optimal mechanical ventilation settings is therefore difficult, where non-optimal mechanical ventilation can be deleterious. To overcome these difficulties, this research proposes a model-based method to manage the wide range of possible mechanical ventilation settings, while also considering patient-specific conditions and responses. METHODS This study shows the design and development of the "VENT" protocol, which integrates the single compartment linear lung model with clinical recommendations from landmark studies, to aid clinical decision-making in selecting mechanical ventilation settings. Using retrospective breath data from a cohort of 24 patients, 3,566 and 2,447 clinically implemented VC and PC settings were extracted respectively. Using this data, a VENT protocol application case study and clinical comparison is performed, and the prediction accuracy of the VENT protocol is validated against actual measured outcomes of pressure and volume. RESULTS The study shows the VENT protocols' potential use in narrowing an overwhelming number of possible mechanical ventilation setting combinations by up to 99.9%. The comparison with retrospective clinical data showed that only 33% and 45% of clinician settings were approved by the VENT protocol. The unapproved settings were mainly due to exceeding clinical recommended settings. When utilising the single compartment model in the VENT protocol for forecasting peak pressures and tidal volumes, median [IQR] prediction error values of 0.75 [0.31 - 1.83] cmH2O and 0.55 [0.19 - 1.20] mL/kg were obtained. CONCLUSIONS Comparing the proposed protocol with retrospective clinically implemented settings shows the protocol can prevent harmful mechanical ventilation setting combinations for which clinicians would be otherwise unaware. The VENT protocol warrants a more detailed clinical study to validate its potential usefulness in a clinical setting.
Collapse
|
48
|
Quantifying neonatal patient effort using non-invasive model-based methods. Med Biol Eng Comput 2022; 60:739-751. [PMID: 35043368 DOI: 10.1007/s11517-021-02491-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 12/15/2021] [Indexed: 10/19/2022]
Abstract
Patient-specific spontaneous breathing effort (SB) is common in invasively mechanically ventilated (MV) adult patients, and especially common in preterm neonates who are not typically sedated. However, there is no proven, ethically feasible and non-invasive method to quantify SB effort in neonates, creating the potential for model-based measures. Lung mechanics and SB effort are segregated using a basis function model to identify passive lung mechanics, and an additional time-varying elastance model to identify patient-specific SB effort and asynchrony as negative and positive added elastances, respectively. Data from ten preterm neonates on standard MV care in the neonatal intensive care unit (NICU) are used to assess this model-based approach, using area under the curve (AUC) for positive (asynchrony) and negative (SB effort) time-varying elastance. Median [interquartile-range (IQR)] of passive pulmonary lung elastance was 3.82 [2.09-5.80] cmH2O/ml. Median [IQR] AUC quantified SB effort was -0.32 [-0.43--0.12]cmH2O/ml. AUC quantified asynchrony was 0.00 [0.00-0.01]cmH2O/ml, and affected 28% of the 25,287 total breaths. This proof of concept model-based approach provides a non-invasive, computationally straightforward, and thus clinically feasible means to quantify patient-specific spontaneous breathing effort and asynchrony.
Collapse
|
49
|
The CREBRF diabetes-protective rs373863828-A allele is associated with enhanced early insulin release in men of Māori and Pacific ancestry. Diabetologia 2021; 64:2779-2789. [PMID: 34417843 DOI: 10.1007/s00125-021-05552-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 06/29/2021] [Indexed: 10/20/2022]
Abstract
AIMS/HYPOTHESIS The minor A allele of rs373863828 (CREBRF p.Arg457Gln) is associated with increased BMI, but reduced risk of type 2 and gestational diabetes in Polynesian (Pacific peoples and Aotearoa New Zealand Māori) populations. This study investigates the effect of the A allele on insulin release and sensitivity in overweight/obese men without diabetes. METHODS A mixed meal tolerance test was completed by 172 men (56 with the A allele) of Māori or Pacific ancestry, and 44 (24 with the A allele) had a frequently sampled IVGTT and hyperinsulinaemic-euglycaemic clamp. Mixed linear models with covariates age, ancestry and BMI were used to analyse the association between the A allele of rs373863828 and markers of insulin release and blood glucose regulation. RESULTS The A allele of rs373863828 is associated with a greater increase in plasma insulin 30 min following a meal challenge without affecting the elevation in plasma glucose or incretins glucagon-like polypeptide-1 or gastric inhibitory polypeptide. Consistent with this point, following an i.v. infusion of a glucose bolus, participants with an A allele had higher early (p < 0.05 at 2 and 4 min) plasma insulin and C-peptide concentrations for a similar elevation in blood glucose as those homozygous for the major (G) allele. Despite increased plasma insulin, rs373863828 genotype was not associated with a significant difference (p > 0.05) in insulin sensitivity index or glucose disposal during hyperinsulinaemic-euglycaemic clamp. CONCLUSIONS/INTERPRETATION rs373863828-A allele associates with increased glucose-stimulated insulin release without affecting insulin sensitivity, suggesting that CREBRF p.Arg457Gln may increase insulin release to reduce the risk of type 2 diabetes.
Collapse
|
50
|
Predicting fluid-response, the heart of hemodynamic management: A model-based solution. Comput Biol Med 2021; 139:104950. [PMID: 34678480 DOI: 10.1016/j.compbiomed.2021.104950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Revised: 09/28/2021] [Accepted: 10/13/2021] [Indexed: 12/21/2022]
Abstract
BACKGROUND Intravenous fluid infusions are an important therapy for patients with circulatory shock. However, it is challenging to predict how patients' cardiac stroke volume (SV) will respond, and thus identify how much fluids should be delivered, if any. Model-predicted SV time-profiles of response to fluid infusions could potentially be used to guide fluid therapy. METHOD A clinically applicable model-based method predicts SV changes in response to fluid-infusions for a pig trial (N = 6). Validation/calibration SV, SVmea, is from an aortic flow probe. Model parameters are identified in 3 ways: fitting to SVmea from the entire infusion, SVflfit, from the first 200 ml, SVfl200, or from the first 100 ml, SVfl100. RMSE compares error of model-based SV time-profiles for each parameter identification method, and polar plot analysis assesses trending ability. Receiver-operating characteristic (ROC) analysis evaluates ability of model-predicted SVs, SVfl200 and SVfl100, to distinguish non-responsive and responsive infusions, using area-under the curve (AUC), and balanced accuracy as a measure of performance. RESULTS RMSE for SVflFit, SVfl200, and SVfl100 was 1.8, 3.2, and 6.5 ml, respectively, and polar plot angular limit of agreement from was 11.6, 28.0, and 68.8°, respectively. For predicting responsive and non-responsive interventions SVfl200, and SVfl100 had ROC AUC of 0.64 and 0.69, respectively, and balanced accuracy was 0.75 in both cases. CONCLUSIONS The model-predicted SV time-profiles matched measured SV trends well for SVflFit, SVfl200, but not SVfl100. Thus, the model can fit the observed SV dynamics, and can deliver good SV prediction given a sufficient parameter identification period. This trial is limited by small numbers and provides proof-of-method, with further experimental and clinical investigation needed. Potentially, this method could deliver model-predicted SV time-profiles to guide fluid therapy decisions, or as part of a closed-loop fluid control system.
Collapse
|