1
|
Uncertainty evaluation of non-invasive multi-parameter detector measurements in quality assurance of diagnostic radiology. J Cancer Res Ther 2024:01363817-990000000-00048. [PMID: 38261422 DOI: 10.4103/jcrt.jcrt_199_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 04/04/2023] [Indexed: 01/25/2024]
Abstract
OBJECTIVE To optimize the patient dose and image quality through quality assurance (QA) of diagnostic x-ray equipment and to ensure compliance with international and national standards in x-ray specification parameters, the use of contactless and quick non-invasive instruments has gained importance. Considering the importance of equipment qualification and the intervention level for equipment management, it is vital to account for uncertainties in the measurement of parameters in diagnostic radiology. However, the limits and measurement uncertainties associated with the parameter measurement are not well established and many technical and scientific literature provide different tolerance values, either as absolute or in terms of percentage. METHODS AND MATERIALS In this paper, the authors analyze non-invasive multi-parameter detector measurements with the aim to (i) improve the accuracy in measurement of x-ray parameters (kilovoltage, dose, and exposure time); (ii) estimate the uncertainty associated with such measurements; (iii) analyze the tolerance values prescribed by various professional and regulatory bodies and propose an improvised method of reporting the parameters. The approach adopted in this paper takes into account the uncertainties associated with traditional instruments and the subjectivity in the measurements. RESULTS Estimated uncertainty for kV measurements in the range between 1.45 kV at 40 kV measurements and 4.88 kV at 150 kV measurements. The MU associated with the dose measurement is estimated to be 6.2% at 110 kVp, 100 mA, and 500 msec. Maximum MU estimated at 10 msec exposure time is 4.5% and with MU of 5% deviation added to 9.5%. CONCLUSIONS The current practice of reporting the measured mean values deviation without considering the inherent measurement uncertainty may not be a correct quantification procedure in QA. This is evident from the case study that 3% addition to the measured kV, 6.2% addition in the measured dose, and 4.5% to the measured time accounts for measurement uncertainty.
Collapse
|
2
|
NUCLEAR MEDICINE PROCEDURE VOLUME AND ESTIMATION OF COLLECTIVE EFFECTIVE DOSE IN TAMIL NADU TOWARDS THE ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVEL. RADIATION PROTECTION DOSIMETRY 2023; 199:373-381. [PMID: 36632802 DOI: 10.1093/rpd/ncac297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 11/18/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
With an objective to establish adult diagnostic reference levels in the practice of nuclear medicine (NM) in the state of Tamil Nadu (TN), data on the predominant NM procedures carried out in the state are analyzed. In this study, data on total NM diagnostic procedures during the years 2015-19 along with patient-specific diagnostic NM procedure data for the period April-June 2021 from all centers in Tamil Nadu are collected and analyzed using SPSS statistical software. Nine predominant types of NM scans are analyzed. Collective effective dose from NM scans and per capita dose for the TN population are estimated. The 75th percentile of the distribution and average administered activity (AAA) has been derived and local reference levels are reported. Based on the statistical analysis, it is observed that the whole-body positron emission tomography (PET), renal diethylenetriamine pentaacetate (DTPA) scan, bone methylene diphosphonate (MDP) scan, iodine-131 whole body scan, thyroid studies using Technetium per technetate, renal dimercaptosuccinic acid (DMSA), myocardial perfusion methoxyisobutyl isonitrile sestamibi (MIBI), mebrofenin, Galium-68 prostate-specific membrane antigen (PSMA) are the most common procedure covering >90% of the practices carried out. The collective effective dose is 410 man-Sv in the year 2019, leading to a mean effective dose of 0.006 mSv per capita of the TN state population. The 75th percentile of the distribution of AA is slightly higher than diagnostic reference level (DRL) as compared with Australian DRL (310 MBq). It is also observed that F-18 PET procedures are primarily responsible for most of the collective effective dose, local DRL is 316 MBq and it is important to establish national DRLs for NM diagnostic scans to optimize the NM examinations.
Collapse
|
3
|
Insights from Magnetic Evoked Field Analysis in Patients with Wilson's Disease. Neurol India 2022; 70:1963-1970. [DOI: 10.4103/0028-3886.359230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
4
|
OCCUPATIONAL EXPOSURE IN RADIATION APPLICATIONS IN INDIA: TRENDS AND DISTRIBUTION ANALYSIS. RADIATION PROTECTION DOSIMETRY 2021; 196:95-103. [PMID: 34514505 DOI: 10.1093/rpd/ncab134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 08/16/2021] [Accepted: 08/22/2021] [Indexed: 06/13/2023]
Abstract
Occupational exposure data in radiation applications provide a good insight on the radiation risks to workers from occupational hazards, the safe practices adopted and in deriving methods to prevent possible radiation exposures. The analysis of occupational exposure may be used to provide regulatory guidance and more focused attention to improve the safety systems, thus improving the personnel and environment safety. In this study, occupational exposure from radiation applications during 2004-18 amounting to a total number of 1951 486 occupational dose data are collected and analysed using the statistical software package, SPSS. As recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation, four critical parameters viz., annual collective effective dose, average annual effective dose, individual dose distribution ratio and the annual collective dose distribution ratio for each practice are estimated. Using the trend observed for these parameters, it is predicted that occupational exposure in diagnostic radiology in the year 2023 would increase by 80% in total number of monitored with 76% increase in average collective dose and no significant change in average annual effective dose. In the same manner, nuclear medicine would see 28% of increase in radiation workers with the increase of 24% in collective dose with no significant change in average annual effective dose. Further, the reasons and area of regulatory focus for the different practices are discussed.
Collapse
|
5
|
Seizure detection and epileptogenic zone localisation on heavily skewed MEG data using RUSBoost machine learning technique. Int J Neurosci 2020; 132:963-974. [PMID: 33272081 DOI: 10.1080/00207454.2020.1858828] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Background: Epilepsy is a neurological disorder which is characterised by recurrent and involuntary seizures. Magnetoencephalography (MEG) is clinically used as a presurgical tool in locating the epileptogenic zone by localising either interictal epileptic discharges (IEDs) or ictal activities. The localisation of ictal onset provides reliable and more accurate seizure onset zones rather than localising the IEDs. Ictals or seizures are presently detected during MEG analysis by manually inspecting the recorded data. This is laborious when the duration of recordings is longer. Methods: We propose a novel method which uses statistical features such as short-time permutation entropy (STPE), gradient of STPE (GSTPE), short-time energy (STE) and short-time mean (STM) extracted from the ictal and interictal MEG data of drug resistant epilepsy patients group. Since the data is heavily skewed, the RUSBoost algorithm with k-fold cross-validation is used to classify the data into ictal and interictal by using the four feature vectors. This method is further used for localising the epileptogenic region using region-specific classifications by means of the RUSBoost algorithm. Results: The accuracy obtained for seizure detection is 93.4%. The specificity and sensitivity for the same are 93%. The localisation accuracies for each lobe are in the range of 88.1-99.1%. Discussion: Through this ictus detection method, the current scenario of laborious inspection of the ictal MEG can be reduced. The proposed system, thus, can be implemented in real-time as a better and more efficient method for seizure detection and further it can prove to be highly beneficial for patients and health-care professionals during real-time MEG recording. Furthermore, the identification of the epileptogenic lobe can provide clinicians with useful insights, and a pre-cursor for source localisation.
Collapse
|
6
|
Fabrication of Scanning Electrochemical Microscopy-Atomic Force Microscopy Probes to Image Surface Topography and Reactivity at the Nanoscale. Anal Chem 2017; 89:2687-2691. [PMID: 28192901 DOI: 10.1021/acs.analchem.7b00210] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Concurrent mapping of chemical reactivity and morphology of heterogeneous electrocatalysts at the nanoscale allows identification of active areas (protrusions, flat film surface, or cracks) responsible for productive chemistry in these materials. Scanning electrochemical microscopy (SECM) can map surface characteristics, record catalyst activity, and identify chemical products at solid-liquid electrochemical interfaces. It lacks, however, the ability to distinguish topographic features where surface reactivity occurs. Here, we report the design and fabrication of scanning probe tips that combine SECM with atomic force microscopy (AFM) to perform measurements at the nanoscale. Our probes are fabricated by integrating nanoelectrodes with quartz tuning forks (QTFs). Using a calibration standard fabricated in our lab to test our probes, we obtain simultaneous topographic and electrochemical reactivity maps with a lateral resolution of 150 nm.
Collapse
|
7
|
Combined MEG-EEG source localisation in patients with sub-acute sclerosing pan-encephalitis. Neurol Sci 2016; 37:1221-31. [PMID: 27056375 DOI: 10.1007/s10072-016-2571-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2015] [Accepted: 02/26/2016] [Indexed: 11/26/2022]
Abstract
To study the genesis and propagation patterns of periodic complexes (PCs) associated with myoclonic jerks in sub-acute sclerosing pan-encephalitis (SSPE) using magnetoencephalography (MEG) and electroencephalography (EEG). Simultaneous recording of MEG (306 channels) and EEG (64 channels) in five patients of SSPE (M:F = 3:2; age 10.8 ± 3.2 years; symptom-duration 6.2 ± 10 months) was carried out using Elekta Neuromag(®) TRIUX™ system. Qualitative analysis of 80-160 PCs per patient was performed. Ten isomorphic classical PCs with significant field topography per patient were analysed at the 'onset' and at 'earliest significant peak' of the burst using discrete and distributed source imaging methods. MEG background was asymmetrical in 2 and slow in 3 patients. Complexes were periodic (3) or quasi-periodic (2), occurring every 4-16 s and varied in morphology among patients. Mean source localization at onset of bursts using discrete and distributed source imaging in magnetic source imaging (MSI) was in thalami and or insula (50 and 50 %, respectively) and in electric source imaging (ESI) was also in thalami and or insula (38 and 46 %, respectively). Mean source localization at the earliest rising phase of peak in MSI was in peri-central gyrus (49 and 42 %) and in ESI it was in frontal cortex (52 and 56 %). Further analysis revealed that PCs were generated in thalami and or insula and thereafter propagated to anterolateral surface of the cortices (viz. sensori-motor cortex and frontal cortex) to same side as that of the onset. This novel MEG-EEG based case series of PCs provides newer insights for understanding the plausible generators of myoclonus in SSPE and patterns of their propagation.
Collapse
|
8
|
Seeing through Walls at the Nanoscale: Microwave Microscopy of Enclosed Objects and Processes in Liquids. ACS NANO 2016; 10:3562-3570. [PMID: 26866377 PMCID: PMC5424529 DOI: 10.1021/acsnano.5b07919] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Noninvasive in situ nanoscale imaging in liquid environments is a current imperative in the analysis of delicate biomedical objects and electrochemical processes at reactive liquid-solid interfaces. Microwaves of a few gigahertz frequencies offer photons with energies of ≈10 μeV, which can affect neither electronic states nor chemical bonds in condensed matter. Here, we describe an implementation of scanning near-field microwave microscopy for imaging in liquids using ultrathin molecular impermeable membranes separating scanning probes from samples enclosed in environmental cells. We imaged a model electroplating reaction as well as individual live cells. Through a side-by-side comparison of the microwave imaging with scanning electron microscopy, we demonstrate the advantage of microwaves for artifact-free imaging.
Collapse
|
9
|
High-contrast and fast electrochromic switching enabled by plasmonics. Nat Commun 2016; 7:10479. [PMID: 26814453 PMCID: PMC4737852 DOI: 10.1038/ncomms10479] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2015] [Accepted: 12/14/2015] [Indexed: 12/24/2022] Open
Abstract
With vibrant colours and simple, room-temperature processing methods, electrochromic polymers have attracted attention as active materials for flexible, low-power-consuming devices. However, slow switching speeds in devices realized to date, as well as the complexity of having to combine several distinct polymers to achieve a full-colour gamut, have limited electrochromic materials to niche applications. Here we achieve fast, high-contrast electrochromic switching by significantly enhancing the interaction of light—propagating as deep-subwavelength-confined surface plasmon polaritons through arrays of metallic nanoslits, with an electrochromic polymer—present as an ultra-thin coating on the slit sidewalls. The switchable configuration retains the short temporal charge-diffusion characteristics of thin electrochromic films, while maintaining the high optical contrast associated with thicker electrochromic coatings. We further demonstrate that by controlling the pitch of the nanoslit arrays, it is possible to achieve a full-colour response with high contrast and fast switching speeds, while relying on just one electrochromic polymer. Slow switching speeds in device configurations have severely limited the applications of electrochromic materials. Here, Xu et al. use plasmonic nanoslit arrays and demonstrate fast, high-contrast, monochromatic and full-colour electrochromic switching using two different electrochromic polymers.
Collapse
|
10
|
Optical Fluorescence Microscopy for Spatially Characterizing Electron Transfer across a Solid-Liquid Interface on Heterogeneous Electrodes. ACTA ACUST UNITED AC 2016; 1:2867-2872. [PMID: 28503329 DOI: 10.1557/adv.2016.289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Heterogeneous catalytic materials and electrodes are used for (electro)chemical transformations, including those important for energy storage and utilization.1, 2 Due to the heterogeneous nature of these materials, activity measurements with sufficient spatial resolution are needed to obtain structure/activity correlations across the different surface features (exposed facets, step edges, lattice defects, grain boundaries, etc.). These measurements will help lead to an understanding of the underlying reaction mechanisms and enable engineering of more active materials. Because (electro)catalytic surfaces restructure with changing environments,1 it is important to perform measurements in operando. Sub-diffraction fluorescence microscopy is well suited for these requirements because it can operate in solution with resolution down to a few nm. We have applied sub-diffraction fluorescence microscopy to a thin cell containing an electrocatalyst and a solution containing the redox sensitive dye p-aminophenyl fluorescein to characterize reaction at the solid-liquid interface. Our chosen dye switches between a nonfluorescent reduced state and a one-electron oxidized bright state, a process that occurs at the electrode surface. This scheme is used to investigate the activity differences on the surface of polycrystalline Pt, in particular to differentiate reactivity at grain faces and grain boundaries. Ultimately, this method will be extended to study other dye systems and electrode materials.
Collapse
|
11
|
Evaluating the image quality of cone beam CT acquired during rotational delivery. Br J Radiol 2015; 88:20150425. [PMID: 26226396 DOI: 10.1259/bjr.20150425] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE The aim of this work was to evaluate the quality of kilovoltage (kV) cone beam CT (CBCT) images acquired during arc delivery. METHODS Arc plans were delivered on a Catphan(®) 600 phantom (The Phantom Laboratory Inc., Salem, NY), and kV CBCT images were acquired during the treatment. The megavoltage (MV) scatter effect on kV CBCT image quality was evaluated using parameters such as Hounsfield unit (HU) accuracy, spatial resolution, contrast-to-noise ratio (CNR) and spatial non-uniformity (SNU). These CBCT images were compared with reference scans acquired with the same acquisition parameters without MV "beam on". This evaluation was carried out for different photon beams (6 and 15 MV), arc types (half vs full arc), static field sizes (10 × 10 and 25 × 25 cm(2)) and source-to-imager distances (SID) (150 and 170 cm). RESULTS AND CONCLUSION HU accuracy, CNR and SNU were considerably affected by MV scatter, and this effect was increased with increasing field size and decreasing photon energy, whereas the spatial resolution was almost unchanged. The MV scatter effect was observed to be more for full-rotation arc delivery than for half-arc delivery. In addition, increasing the SID resulted in decreased MV scatter effect and improved the image quality. ADVANCES IN KNOWLEDGE Nowadays, volumetric modulated arc therapy (VMAT) is increasingly used in clinics, and this arc therapy enables us to acquire CBCT imaging simultaneously. But, the main issue of concurrent imaging is the "MV scatter" effect on CBCT imaging. This study aims to experimentally quantify the effect of MV scatter on CBCT image quality.
Collapse
|
12
|
Scanning electrochemical microscopy as a novel proximity sensor for atraumatic cochlear implant insertion. IEEE Trans Biomed Eng 2015; 61:1822-32. [PMID: 24845292 DOI: 10.1109/tbme.2014.2308058] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
A growing number of minimally invasive surgical and diagnostic procedures require the insertion of an optical, mechanical, or electronic device in narrow spaces inside a human body. In such procedures, precise motion control is essential to avoid damage to the patient's tissues and/or the device itself. A typical example is the insertion of a cochlear implant which should ideally be done with minimum physical contact between the moving device and the cochlear canal walls or the basilar membrane. Because optical monitoring is not possible, alternative techniques for sub millimeter-scale distance control can be very useful for such procedures. The first requirement for distance control is distance sensing. We developed a novel approach to distance sensing based on the principles of scanning electrochemical microscopy (SECM). The SECM signal, i.e., the diffusion current to a microelectrode, is very sensitive to the distance between the probe surface and any electrically insulating object present in its proximity. With several amperometric microprobes fabricated on the surface of an insertable device, one can monitor the distances between different parts of the moving implant and the surrounding tissues. Unlike typical SECM experiments, in which a disk-shaped tip approaches a relatively smooth sample, complex geometries of the mobile device and its surroundings make distance sensing challenging. Additional issues include the possibility of electrode surface contamination in biological fluids and the requirement for a biologically compatible redox mediator.
Collapse
|
13
|
P1015: Source localization and propagation of periodic complexes in subacute sclerosing pan encephalitis (SSPE) using MEG-EEG: a novel approach towards understanding subcortical myoclonus. Clin Neurophysiol 2014. [DOI: 10.1016/s1388-2457(14)51054-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
|
15
|
A study on comparison of Gafchromic EBT2 film response under single and cumulative exposure conditions. J Med Phys 2013; 38:173-7. [PMID: 24672151 PMCID: PMC3958996 DOI: 10.4103/0971-6203.121194] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Revised: 09/21/2013] [Accepted: 09/21/2013] [Indexed: 11/04/2022] Open
Abstract
Gafchromic films are used as dosimeter for in vivo and in phantom dose measurements. The dose response of Gafchromic EBT2 film under single and repeated exposure conditions is compared in this study to analyze the usability of Gafchromic EBT2 films in cumulative dose measurements. The post-irradiation change in response of the film is studied for up to 4 days after irradiation. The effect of repeated exposure to scanner light on the response of the film is also studied. To check usability of Gafchromic EBT2 films in cumulative dose measurements, three EBT2 films were exposed to a daily fraction dose of 100 cGy, 150 cGy and 200 cGy, respectively, for 4 days. The dose response of the films exposed to cumulative irradiation was compared with the dose measured from films exposed to the same dose but in a single exposure. It is observed that the post-irradiation darkening of the film does not saturate and continue to take place even 4 days after irradiation. The dose measured from the EBT2 films after 4 days from irradiation was around 2% higher than the dose measured from the same films at 24 hours post-irradiation. It was also observed that the repeated exposure to scanner light does not produce any significant change in the film response. The dose response of films exposed to cumulative irradiation agrees with the dose response of films exposed to the same dose in a single irradiation with less than 3% difference. Gafchromic EBT2 films can be used to measure the cumulative dose delivered over multiple fractions, when the delivered dose is uniform across the film.
Collapse
|
16
|
Comparative analysis between 5 mm and 7.5 mm collimators in CyberKnife radiosurgery for trigeminal neuralgia. J Med Phys 2013; 38:120-4. [PMID: 24049318 PMCID: PMC3775035 DOI: 10.4103/0971-6203.116364] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Revised: 04/02/2013] [Accepted: 04/18/2013] [Indexed: 11/06/2022] Open
Abstract
Trigeminal neuralgia (TN) is treated in CyberKnife (Accuray Inc, Sunnyvale, USA) with the 5 mm collimator whose dosimetric inaccuracy is higher than the other available collimators. The 7.5 mm collimator which is having less dosimetric uncertainty can be an alternative for 5 mm collimator provided the dose distribution with 7.5 mm collimator is acceptable. Aim of this study is to analyze the role of 7.5 mm collimator in CyberKnife treatment plans of TN. The treatment plans with 5 mm collimators were re-optimized with 7.5 mm collimator and a bi-collimator system (5 mm and 7.5 mm). The treatment plans were compared for target coverage, brainstem doses, and the dose to normal tissues. The target and brainstem doses were comparable. However, the conformity indices were 2.31 ± 0.52, 2.40 ± 0.87 and 2.82 ± 0.51 for 5 mm, bi-collimator (5mm and 7.5 mm), 7.5 mm collimator plans respectively. This shows the level of dose spillage in 7.5 mm collimator plans. The 6 Gy dose volumes in 7.5 mm plans were 1.53 and 1.34 times higher than the 5 mm plan and the bi-collimator plans respectively. The treatment time parameters were lesser for 7.5 mm collimators. Since, the normal tissue dose is pretty high in 7.5 mm collimator plans, the use of it in TN plans can be ruled out though the treatment time is lesser for these 7.5 mm collimator plans.
Collapse
|
17
|
A study on rectal dose measurement in phantom and in vivo using Gafchromic EBT3 film in IMRT and CyberKnife treatments of carcinoma of prostate. J Med Phys 2013; 38:132-8. [PMID: 24049320 PMCID: PMC3775037 DOI: 10.4103/0971-6203.116372] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2013] [Revised: 07/06/2013] [Accepted: 07/06/2013] [Indexed: 11/18/2022] Open
Abstract
The objective of this study is to check the feasibility of in vivo rectal dose measurement in intensity-modulated radiotherapy (IMRT) and CyberKnife treatments for carcinoma prostate. An in-house pelvis phantom made with bee's wax was used in this study. Two cylindrical bone equivalent materials were used to simulate the femur. Target and other critical structures associated with carcinoma prostate were delineated on the treatment planning images by the radiation oncologist. IMRT treatment plan was generated in Oncentra Master Plan treatment planning system and CyberKnife treatment plan was generated in Multiplan treatment planning system. Dose measurements were carried out in phantom and in patient using Gafchromic EBT3 films. RIT software was used to analyze the dose measured by EBT3 films. The measured doses using EBT3 films were compared with the TPS-calculated dose along the anterior rectal wall at multiple points. From the in-phantom measurements, it is observed that the difference between calculated and measured dose was mostly within 5%, except for a few measurement points. The difference between calculated and measured dose in the in-patient measurements was higher than 5% in regions which were away from the target. Gafchromic EBT3 film is a suitable detector for in vivo rectal dose measurements as it offers the possibility of analyzing the dose at multiple points. In addition, the method of extending this in vivo rectal dose measurement technique as a tool for patient-specific quality assurance check is also analyzed.
Collapse
|
18
|
Analysis of high-dose rate brachytherapy dose distribution resemblance in CyberKnife hypofractionated treatment plans of localized prostate cancer. Med Dosim 2013; 38:385-9. [PMID: 23809693 DOI: 10.1016/j.meddos.2013.04.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2012] [Revised: 03/05/2013] [Accepted: 04/26/2013] [Indexed: 11/17/2022]
Abstract
The present study is to analyze the CyberKnife hypofractionated dose distribution of localized prostate cancer in terms of high-dose rate (HDR) brachytherapy equivalent doses to assess the degree of HDR brachytherapy resemblance of CyberKnife dose distribution. Thirteen randomly selected localized prostate cancer cases treated using CyberKnife with a dose regimen of 36.25Gy in 5 fractions were considered. HDR equivalent doses were calculated for 30Gy in 3 fractions of HDR brachytherapy regimen. The D5% of the target in the CyberKnife hypofractionation was 41.57 ± 2.41Gy. The corresponding HDR fractionation (3 fractions) equivalent dose was 32.81 ± 1.86Gy. The mean HDR fractionation equivalent dose, D98%, was 27.93 ± 0.84Gy. The V100% of the prostate target was 95.57% ± 3.47%. The V100% of the bladder and the rectum were 717.16 and 79.6mm(3), respectively. Analysis of the HDR equivalent dose of CyberKnife dose distribution indicates a comparable resemblance to HDR dose distribution in the peripheral target doses (D98% to D80%) reported in the literature. However, there is a substantial difference observed in the core high-dose regions especially in D10% and D5%. The dose fall-off within the OAR is also superior in reported HDR dose distribution than the HDR equivalent doses of CyberKnife.
Collapse
|
19
|
Patient dose analysis in total body irradiation through in vivo dosimetry. J Med Phys 2013; 37:214-8. [PMID: 23293453 PMCID: PMC3532750 DOI: 10.4103/0971-6203.103607] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2012] [Revised: 08/13/2012] [Accepted: 10/09/2012] [Indexed: 11/04/2022] Open
Abstract
Total body irradiation (TBI) is a special radiotherapy technique, administered prior to bone marrow transplantation. Due to the complex nature of the treatment setup, in vivo dosimetry for TBI is mandatory to ensure proper delivery of the intended radiation dose throughout the body. Lithium fluoride (LiF) TLD-100 chips are used for the TBI in vivo dosimetry. Results obtained from the in vivo dosimetry of 20 patients are analyzed. Results obtained from forehead, abdomen, pelvis, and mediastinum showed a similar pattern with the average measured dose from 96 to 97% of the prescription dose. Extremities and chest received a dose greater than the prescription dose in many instances (more than 20% of measurements). Homogeneous dose delivery to the whole body is checked by calculating the mean dose with standard deviation for each fraction. Reasons for the difference between prescription dose and measured dose for each site are discussed. Dose homogeneity within ±10% is achieved using our in-house TBI protocol.
Collapse
|
20
|
Electron transfer/ion transfer mode of scanning electrochemical microscopy (SECM): a new tool for imaging and kinetic studies. Chem Sci 2013. [DOI: 10.1039/c3sc50825k] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
21
|
Influence of smoothing algorithms in Monte Carlo dose calculations of cyberknife treatment plans: a lung phantom study. J Cancer Res Ther 2012; 8:367-72. [PMID: 23174716 DOI: 10.4103/0973-1482.103514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AIM The Monte Carlo dose calculation algorithm yields accurate dose distributions in heterogeneous media and interfaces. The Monte Carlo calculation algorithm provided in the Multiplan Cyberknife treatment planning system (Accuray, Sunnyvale, CA, USA) has five different dose-smoothing algorithms in it. As the principle of smoothing of these algorithms is different, they can produce a disparity in the final dose distribution. The aim of the present study is to analyze the influence of these Monte Carlo smoothing algorithms in the final dose distribution of cyberknife treatment plans. MATERIALS AND METHODS An anthropomorphic lung phantom with a tumor mimicking ball target was taken for this study. The basic optimization was performed with the Ray tracing algorithm. The Monte Carlo calculations were introduced with each smoothing algorithm on the basic plan and the plans were compared. RESULTS The Monte Carlo doses were found to be lesser than the Ray tracing doses. The dose conformity index was above 4 for all the smoothing algorithms, while it was only 1.19 for Ray tracing. The least coverage of 6.34 was obtained for a weighted average algorithm. The deviation between the V100% values of different smoothing algorithms was higher than the deviation in V80%. CONCLUSION The deviations between the smoothing algorithms are higher in the high-dose regions, including the prescribing isodose, than the low-dose regions of the target, as well as in the organs at risk (OAR).
Collapse
|
22
|
Equivalent normalized total dose estimates in cyberknife radiotherapy dose delivery in prostate cancer hypofractionation regimens. J Med Phys 2012; 37:90-6. [PMID: 22557798 PMCID: PMC3339148 DOI: 10.4103/0971-6203.94743] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Revised: 10/15/2011] [Accepted: 10/18/2011] [Indexed: 11/04/2022] Open
Abstract
As the α/β value of prostate is very small and lower than the surrounding critical organs, hypofractionated radiotherapy became a vital mode of treatment of prostate cancer. Cyberknife (Accuray Inc., Sunnyvale, CA, USA) treatment for localized prostate cancer is performed in hypofractionated dose regimen alone. Effective dose escalation in the hypofractionated regimen can be estimated if the corresponding conventional 2 Gy per fraction equivalent normalized total dose (NTD) distribution is known. The present study aims to analyze the hypofractionated dose distribution of localized prostate cancer in terms of equivalent NTD. Randomly selected 12 localized prostate cases treated in cyberknife with a dose regimen of 36.25 Gy in 5 fractions were considered. The 2 Gy per fraction equivalent NTDs were calculated using the formula derived from the linear quadratic (LQ) model. Dose distributions were analyzed with the corresponding NTDs. The conformity index for the prescribed target dose of 36.25 Gy equivalent to the NTD dose of 90.63 Gy (α/β = 1.5) or 74.31 Gy (α/β = 3) was ranging between 1.15 and 1.73 with a mean value of 1.32 ± 0.15. The D5% of the target was 111.41 ± 8.66 Gy for α/β = 1.5 and 90.15 ± 6.57 Gy for α/β = 3. Similarly, the D95% was 91.98 ± 3.77 Gy for α/β = 1.5 and 75.35 ± 2.88 Gy for α/β = 3. The mean values of bladder and rectal volume receiving the prescribed dose of 36.25 Gy were 0.83 cm3 and 0.086 cm3, respectively. NTD dose analysis shows an escalated dose distribution within the target for low α/β (1.5 Gy) with reasonable sparing of organs at risk. However, the higher α/β of prostate (3 Gy) is not encouraging the fact of dose escalation in cyberknife hypofractionated dose regimen of localized prostate cancer.
Collapse
|
23
|
Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system. J Med Phys 2012; 37:4-7. [PMID: 22363106 PMCID: PMC3283915 DOI: 10.4103/0971-6203.92714] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2011] [Revised: 09/03/2011] [Accepted: 09/05/2011] [Indexed: 11/08/2022] Open
Abstract
Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuray Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1–10), medium (15–100) and large (125–1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of –38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was –2.4%. In the large MU range, the linearity error varied between –0.7% and 1.2%. The maximum deviation in the MU stability was –3.03%.
Collapse
|
24
|
Dosimetric analysis of trigeminal nerve, brain stem doses in CyberKnife radiosurgery of trigeminal neuralgia. J Med Phys 2012; 37:124-8. [PMID: 22973078 PMCID: PMC3437168 DOI: 10.4103/0971-6203.99225] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2012] [Revised: 03/30/2012] [Accepted: 04/19/2012] [Indexed: 11/04/2022] Open
Abstract
CyberKnife radiosurgery treatment of Trigeminal neuralgia (TN) is performed as a non-invasive image guided procedure. The prescription dose for TN is very high. The brainstem is the adjacent critical organ at risk (OAR) which is prone to receive the very high target dose of TN. The present study is to analyze the dose distribution inside the tiny trigeminal nerve target and also to analyze the dose fall off in the brain stem. Seven TN cases treated between November 2010 and January 2012 were taken for this study retrospectively. The treatment plans were analyzed for target dose conformity, homogeneity and dose coverage. In the brainstem the volume doses D(1%), D(2%) were taken for analyzing the higher doses in the brain stem. The dose fall off was analyzed in terms of D(5%) and D(10%). The mean value of maximum dose within the trigeminal nerve target was 73.5±2.1Gy (P=0.0007) and the minimum dose was 50.0±4.1Gy (P=0.1315). The mean conformity index was 2.19 and the probable reason could be the smallest CyberKnife collimator of 5mm used in the treatment plan. The mean D(1%), of the brainstem was 10.5± 2.1Gy (P=0.5316) and the mean value of the maximum point dose within the brainstem was 35.6±3.8Gy. This shows the degree of dose fall off within the brainstem. Though the results of the present study are showing superior sparing of brain stem and reasonable of target coverage, it is necessary to execute the treatment plan with greater accuracy in CyberKnife as the immobilization is noninvasive and frameless.
Collapse
|
25
|
|
26
|
Nanoelectrodes for determination of reactive oxygen and nitrogen species inside murine macrophages. Proc Natl Acad Sci U S A 2012; 109:11534-9. [PMID: 22615353 PMCID: PMC3406879 DOI: 10.1073/pnas.1201552109] [Citation(s) in RCA: 156] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Reactive oxygen and nitrogen species (ROS and RNS) produced by macrophages are essential for protecting a human body against bacteria and viruses. Micrometer-sized electrodes coated with Pt black have previously been used for selective and sensitive detection of ROS and RNS in biological systems. To determine ROS and RNS inside macrophages, one needs smaller (i.e., nanometer-sized) sensors. In this article, the methodologies have been extended to the fabrication and characterization of Pt/Pt black nanoelectrodes. Electrodes with the metal surface flush with glass insulator, most suitable for quantitative voltammetric experiments, were fabricated by electrodeposition of Pt black inside an etched nanocavity under the atomic force microscope control. Despite a nanometer-scale radius, the true surface area of Pt electrodes was sufficiently large to yield stable and reproducible responses to ROS and RNS in vitro. The prepared nanoprobes were used to penetrate cells and detect ROS and RNS inside macrophages. Weak and very short leaks of ROS/RNS from the vacuoles into the cytoplasm were detected, which a macrophage is equipped to clean within a couple of seconds, while higher intensity oxidative bursts due to the emptying of vacuoles outside persist on the time scale of tens of seconds.
Collapse
|
27
|
|
28
|
|
29
|
Different intensity extension methods and their impact on entrance dose in breast radiotherapy: A study. J Med Phys 2011; 34:200-5. [PMID: 20098549 PMCID: PMC2807141 DOI: 10.4103/0971-6203.56079] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2009] [Revised: 03/29/2009] [Accepted: 04/26/2009] [Indexed: 12/04/2022] Open
Abstract
In breast radiotherapy, skin flashing of treatment fields is important to account for intrafraction movements and setup errors. This study compares the two different intensity extension methods, namely, Virtual Bolus method and skin flash tool method, to provide skin flashing in intensity modulated treatment fields. The impact of these two different intensity extension methods on skin dose was studied by measuring the entrance dose of the treatment fields using semiconductor diode detectors. We found no significant difference in entrance dose due to different methods used for intensity extension. However, in the skin flash tool method, selection of appropriate parameters is important to get optimum fluence extension.
Collapse
|
30
|
Evaluation of gafchromic EBT film for intensity modulated radiation therapy dose distribution verification. J Med Phys 2011; 31:78-82. [PMID: 21206669 PMCID: PMC3004140 DOI: 10.4103/0971-6203.26693] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2005] [Accepted: 06/16/2006] [Indexed: 11/07/2022] Open
Abstract
This work was undertaken with the intention of investigating the possibility of clinical use of commercially available self-developing radiochromic film – Gafchromic EBT film – for IMRT dose verification. The dose response curves were generated for the films using VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak EDR2 films. It was found that the EBT film has a linear response between the dose ranges of 0 and 600 cGy. The dose-related characteristics of the EBT film, like post-irradiation color growth with time, film uniformity and effect of scanning orientation, were studied. There is up to 8.6% increase in the color density between 2 and 40 h after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative difference between calculated and measured dose distributions was analyzed using Gamma index with the tolerance of 3% dose difference and 3 mm distance agreement. EDR2 films showed good and consistent results with the calculated dose distribution, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large field IMRT verification. For IMRT of smaller field size (4.5 × 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films.
Collapse
|
31
|
The 2011 Joseph W. Richards Summer Research Fellowship -- Summary Report: Electrodeposition at Nanoelectrodes. ELECTROCHEMICAL SOCIETY INTERFACE 2011. [DOI: 10.1149/2.f08114if] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
32
|
Scanning electrochemical microscopy in the 21st century. Update 1: five years after. Phys Chem Chem Phys 2011; 13:21196-212. [DOI: 10.1039/c1cp22376c] [Citation(s) in RCA: 113] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
33
|
Polished Nanopipets: New Probes for High-Resolution Scanning Electrochemical Microscopy. Anal Chem 2010; 83:671-3. [DOI: 10.1021/ac102704z] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
34
|
|
35
|
|
36
|
|
37
|
Kinetic study of rapid transfer of tetraethylammonium at the 1,2-dichloroethane/water interface by nanopipet voltammetry of common ions. Anal Chem 2010; 82:77-83. [PMID: 20000449 DOI: 10.1021/ac902244s] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Steady-state voltammetry at the pipet-supported liquid/liquid interface has previously been used to measure kinetics of simple and facilitated ion transfer (IT) processes. Recently, we showed that the conventional experimental protocol and data analysis produce large uncertainties in kinetic parameters of rapid IT processes extracted from pipet voltammograms. Here, we used a new mode of nanopipet voltammetry, in which a transferable ion is initially present as a common ion in both liquid phases, and improved methodology for silanization of the outer pipet wall to investigate the kinetics of the rapid transfer of tetraethylammonium (TEA(+)) at the 1,2-dichloroethane/water interface. This reaction was often employed as a model system to check the IT theory. The determined standard rate constant and transfer coefficient of the TEA(+) transfer are compared with previously reported values to demonstrate limitations of conventional nanopipet voltammetry with a transferrable ion present only in one liquid phase.
Collapse
|
38
|
Adsorption/Desorption of Hydrogen on Pt Nanoelectrodes: Evidence of Surface Diffusion and Spillover. J Am Chem Soc 2009; 131:14756-60. [DOI: 10.1021/ja902876v] [Citation(s) in RCA: 150] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
39
|
Nanoscale Imaging of Surface Topography and Reactivity with the Scanning Electrochemical Microscope. Anal Chem 2009; 81:3143-50. [DOI: 10.1021/ac900335c] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
40
|
Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification. Med Dosim 2006; 31:273-82. [PMID: 17134667 DOI: 10.1016/j.meddos.2006.06.001] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2005] [Accepted: 06/02/2006] [Indexed: 10/23/2022]
Abstract
The quantitative dose validation of intensity-modulated radiation therapy (IMRT) plans require 2-dimensional (2D) high-resolution dosimetry systems with uniform response over its sensitive region. The present work deals with clinical use of commercially available self-developing Radio Chromic Film, Gafchromic EBT film, for IMRT dose verification. Dose response curves were generated for the films using a VXR-16 film scanner. The results obtained with EBT films were compared with the results of Kodak extended dose range 2 (EDR2) films. The EBT film had a linear response between the dose range of 0 to 600 cGy. The dose-related characteristics of the EBT film, such as post irradiation color growth with time, film uniformity, and effect of scanning orientation, were studied. There was up to 8.6% increase in the color density between 2 to 40 hours after irradiation. There was a considerable variation, up to 8.5%, in the film uniformity over its sensitive region. The quantitative differences between calculated and measured dose distributions were analyzed using DTA and Gamma index with the tolerance of 3% dose difference and 3-mm distance agreement. The EDR2 films showed consistent results with the calculated dose distributions, whereas the results obtained using EBT were inconsistent. The variation in the film uniformity limits the use of EBT film for conventional large-field IMRT verification. For IMRT of smaller field sizes (4.5 x 4.5 cm), the results obtained with EBT were comparable with results of EDR2 films.
Collapse
|
41
|
Radiobiological considerations of re-irradiation tolerance of the spinal cord. Rep Pract Oncol Radiother 2002. [DOI: 10.1016/s1507-1367(02)70982-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
42
|
Prognostic factors for spinal cord myelitis--an analysis of compiled literature data. Indian J Cancer 1998; 35:33-7. [PMID: 9847468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The effectiveness of radiotherapy in the treatment of malignant tumors in the head and neck, thorasic and upper abdominal regions is frequently limited by the tolerance of the spinal cord. Therefore knowledge of the factors that influence the tolerance of the spinal cord to radiation is of the upmost important. Safe limits for irradiation of the spinal cord determined in a number of clinical studies is on the conservative side from the point of view of tumor control probability. The bioeffect of a physical dose takes into account the treatment variables and the radiobiological characteristics of the relevant tissue; hence deciding spinal cord tolerance on the basis of bioeffect models would be better approach. The aim of the present study was to analyze the relationship of the prognostic factors with percentage incidence of spinal cord myelitis and to arrive at a spinal cord tolerance bioeffect dose TDF and ERD for optimum incidence of radiation myelitis.
Collapse
|