1
|
Feasibility Study: Towards a Robot-Assisted Gait Training in Ophthalmological Rehabilitation. IEEE Int Conf Rehabil Robot 2023; 2023:1-6. [PMID: 37941232 DOI: 10.1109/icorr58425.2023.10304760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
The idea of using mobile assistance robots for gait training in rehabilitation has been increasingly explored in recent years due to the associated benefits. This paper describes how the previous results of research and praxis on gait training with a mobile assistance robot in orthopedic rehabilitation can be transferred to ophthalmic-related orientation and mobility training for blind and visually impaired people. To this end, the specific requirements for such orientation and mobility training are presented from a therapeutic perspective. Using sensory data, it is investigated how the analysis of training errors can be automated and transferred back to the training person. These pre-examinations are the prerequisite for any form of robot-assisted mobile gait training in ophthamological rehabilitation, which does not exist so far and which is expected to be of great benefit to these patients.
Collapse
|
2
|
Abstract
PURPOSE To evaluate the 10-year results of femtosecond lenticule extraction (FLEx) for treatment of myopia and myopic astigmatism. METHODS This long-term follow-up of a prospective clinical trial was conducted at HELIOS Klinikum Erfurt and Phillips University of Marburg, Germany. In 2006, 108 eyes underwent the FLEx procedure. All patients were invited for reexamination 10 years after FLEx treatment for myopia and astigmatism. Visual acuity, objective and manifest refraction, intraocular pressure, and slit-lamp examination and side effects were documented. Main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuity, objective and manifest refraction, and slit-lamp examination and side effects. RESULTS A total of 77 eyes of 40 patients of the original treatment group volunteered for a reexamination 10 years after surgery. The mean age of the patients was 45.9 years; 26 were women and 14 were men. UDVA was 0.09 ± 0.19 logMAR and CDVA was stable at -0.1 ± 0.09 logMAR. More than half of the eyes gained one or two Snellen lines, and none of the eyes lost two or more lines. Over the 10-year period, regression was 0.18 D. CONCLUSIONS FLEx has stable results 10 years after treatment for myopia and astigmatism. [J Refract Surg. 2019;35(11):707-711.].
Collapse
|
3
|
10-Year Results of Small Incision Lenticule Extraction. J Refract Surg 2019; 35:618-623. [DOI: 10.3928/1081597x-20190826-02] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 08/26/2019] [Indexed: 11/20/2022]
|
4
|
Interface morphology and gas production by a refractive 347 nm ultraviolet femtosecond laser: Comparison with established laser systems. J Cataract Refract Surg 2018; 44:1371-1377. [DOI: 10.1016/j.jcrs.2018.05.030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 03/13/2018] [Accepted: 05/25/2018] [Indexed: 10/28/2022]
|
5
|
Influence of the beam profile crosslinking setting on changes in corneal topography and tomography in progressive keratoconus: Preliminary results. J Cataract Refract Surg 2018; 44:718-724. [PMID: 29778454 DOI: 10.1016/j.jcrs.2018.03.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 03/06/2018] [Accepted: 03/23/2018] [Indexed: 10/14/2022]
Abstract
PURPOSE To evaluate the effect of accelerated corneal crosslinking (CXL) with a "higher peripheral intensity" profile setting compared with a standard "top hat" profile setting performed using different CXL systems. SETTING Department of Ophthalmology, University Hospital Carl Gustav Carus, Dresden, Germany. DESIGN Retrospective case series. METHODS Eyes from patients with progressive keratoconus were included. Group 1 included eyes treated with the higher peripheral intensity profile. Group 2 included eyes treated with the top hat profile. Accelerated CXL was performed based on the modified Dresden protocol (9 mW/cm2, 10 minutes). Corneal-topography and tomography are characterized using the Pentacam Scheimpflug system. RESULTS The study comprised 45 eyes (25 eyes in Group 1, 20 eyes in Group 2) from 45 patients. The keratometry (K) at the apex (maximum K) decreased significantly from 54.95 diopters (D) ± 6.73 (SD) to 53.21 ± 6.05 D for Group 1 (P < .001) and from 57.29 ± 7.16 D to 56.48 ± 6.88 D for Group 2 (P = .01). In Group 1, flat K (K1) and steep K (K2) decreased significantly after treatment (P < .05). The thinnest corneal thickness decreased significantly by -17.5 ± 21.9 μm (P = .001) in Group 1. In Group 2, no significant flattening was observed in K1 and K2 (P > .05), and the thinnest corneal thickness showed a slight but not significant thinning (P = .097). CONCLUSIONS In Group 1 (the higher peripheral intensity group), the corneal topographic and tomographic parameters improved significantly after accelerated CXL. The higher peripheral intensity profile effect on keratoconic cornea flattening seemed to be more pronounced compared with the top hat profile.
Collapse
|
6
|
Topical administration of regorafenib eye drops: phase I dose-escalation study in healthy volunteers. Br J Clin Pharmacol 2018; 84:865-875. [PMID: 29315699 PMCID: PMC5903260 DOI: 10.1111/bcp.13502] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 12/15/2017] [Accepted: 12/24/2017] [Indexed: 12/19/2022] Open
Abstract
Aim Regorafenib is a multikinase inhibitor under investigation for use in neovascular age‐related macular degeneration. In this phase I study, regorafenib eye drops were administered to healthy volunteers to provide information on safety, tolerability and systemic exposure. Methods This was a single‐centre, randomized, double‐masked, parallel‐group, dose‐escalation, placebo‐controlled study. Subjects received regorafenib eye drops (30 mg ml−1, 25 μl) as a 0.75 mg single dose (Cohort 1), 0.75 mg twice daily (bid) or thrice daily (tid) over 14 days (Cohorts 2 and 3, respectively), 1.5 mg tid unilaterally for 3 days, then bilaterally for up to 14 days (Cohort 4), or placebo. Plasma samples were taken to estimate systemic exposure. Safety and functional assessments were performed throughout the study. Results Thirty‐six subjects received regorafenib and 12 received placebo. Regorafenib was safe and well tolerated over the dose range. No pathological changes occurred in the anterior, vitreous or posterior eye compartments. Mild eyelid redness, oedema and conjunctival hyperaemia were observed across all regorafenib cohorts; these were comparable with the effects seen with placebo. Predominant symptoms were blurred vision in the active and placebo groups. Systemic safety evaluations showed no clinically relevant findings. Absolute systemic exposure after multiple administrations of regorafenib eye drops at a dose of 0.75 mg was 600–700‐fold lower than after multiple oral administration of 160 mg day−1, the dose approved in cancer indications. Conclusion These results indicate a favourable safety and tolerability profile of regorafenib eye drops up to 30 mg ml−1 tid for use in clinical studies.
Collapse
|
7
|
Repeatability and Agreement of Central Corneal Thickness and Keratometry Measurements between Four Different Devices. J Ophthalmol 2017; 2017:6181405. [PMID: 28357136 PMCID: PMC5357553 DOI: 10.1155/2017/6181405] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 01/05/2017] [Accepted: 01/19/2017] [Indexed: 11/29/2022] Open
Abstract
Background. To estimate repeatability and comparability of central corneal thickness (CCT) and keratometry measurements obtained by four different devices in healthy eyes. Methods. Fifty-five healthy eyes from 55 volunteers were enrolled in this study. CCT (IOLMaster 700, Pentacam HR, and Cirrus HD-OCT) and keratometry readings (IOLMaster 700, Pentacam HR, and iDesign) were measured. For statistical analysis, the corneal spherocylinder was converted into power vectors (J0, J45). Repeatability was assessed by intraclass correlation coefficient (ICC). Agreement of measurements between the devices was evaluated by the Bland-Altman method. Results. The analysis of repeatability of CCT data of IOLMaster 700, Pentacam HR, and Cirrus HD-OCT showed high ICCs (range 0.995 to 0.999). The comparison of CCT measurements revealed statistically significant differences between Pentacam HR versus IOLMaster 700 (p < 0.0001) and Pentacam HR versus Cirrus HD-OCT (p < 0.0001), respectively. There was no difference in CCT measurements between IOLMaster 700 and Cirrus HD-OCT (p = 0.519). The repeatability of keratometry readings (J0 and J45) of IOLMaster 700, Pentacam HR, and iDesign was also high with ICCs ranging from 0.974 to 0.999. The Pentacam HR revealed significantly higher J0 in comparison to IOLMaster 700 (p = 0.009) and iDesign (p = 0.041); however, no significant difference was between IOLMaster 700 and iDesign (p = 0.426). Comparison of J45 showed no significant difference between IOLMaster 700, Pentacam HR, and iDesign. These results were in accordance with Bland-Altman plots. Conclusion. In clinical practice, the devices analyzed should not be used interchangeably due to low agreement regarding CCT as well as keratometry readings.
Collapse
|
8
|
Abstract
With a rate of less than 2 %, retreatment after SMILE is rare. If a touch-up is required, there are different options to choose from: surface ablation (PRK/LASEK) with Mitomycin C, the standard femto-flap procedure with the same parameters, the CIRCLE procedure, which extends the previous SMILE interface into a flap, or the innovative but off-label capless SMILE procedure, which preserves all the advantages of SMILE.
Collapse
|
9
|
[Historical Overview of the Clinical Development of the Small Incision Lenticule Extraction Surgery (SMILE)]. Klin Monbl Augenheilkd 2017; 234:117-122. [PMID: 28135748 DOI: 10.1055/s-0042-115944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The clinical use of femtosecond lasers has led to significant progress in the quality of refractive surgery. SMILE femtosecond laser surgery (SMILE: Small Incision Lenticule Extraction) permits the first one step intrastromal laser procedure without a flap. This article describes the gradual development of this surgery during the last ten years.
Collapse
|
10
|
Five-year results of Small Incision Lenticule Extraction (ReLEx SMILE). Br J Ophthalmol 2016; 100:1192-5. [DOI: 10.1136/bjophthalmol-2015-306822] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Accepted: 11/28/2015] [Indexed: 11/03/2022]
|
11
|
[Manifestation of bilateral choroidal osteoma in childhood. Progressive myopia due to staphyloma posticum]. Ophthalmologe 2015; 113:160-3. [PMID: 26062716 DOI: 10.1007/s00347-015-0065-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Case report of a 6-year-old boy with bilateral choroidal osteoma. CASE REPORT The patient was followed up for the next 6 years and during this period bilateral tumor progression was observed. In one eye a staphyloma posticum developed in the area of the osteoma which led to secondary anisometric myopia. CONCLUSION If undetected, this rare complication can lead to anisometric amblyopia; therefore, repeated cycloplegic refractometry is advisable in children with choroidal osteoma.
Collapse
|
12
|
[One-year results of small incision lenticule extraction (SMILE) in myopia]. Klin Monbl Augenheilkd 2014; 232:67-71. [PMID: 25272083 DOI: 10.1055/s-0034-1383053] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
BACKGROUND This clinical trial is focused on the 12-month results of a new method for refractive correction in myopia, called "small incision lenticule extraction" (SMILE). PATIENTS AND METHODS In a prospective study 91 eyes were treated with the new refractive procedure and the results were published after 6 months. A lenticule of intrastromal corneal tissue is cut utilising the Carl Zeiss Meditec AG (Jena, Germany) VisuMax femtosecond laser system. Thereafter, this lenticule is manually removed without lifting a flap. 55 eyes of 33 patients volunteered for a 12-month follow-up. UCVA and BSCVA after 12 months, objective and manifest refraction as well as slit-lamp examination and late side effects were documented. RESULTS 55 eyes of 33 patients were re-examined in this study 12 months after surgery. The spherical equivalent before surgery was - 4.66 (± 1.75) D; after 12 months - 0.11 (± 0.42) D was manifest. No significant change was observed compared to the 6-month control. Starting with UCVA of 0.1 (± 0.06) before surgery. UCVA was 1.02 (± 0.3) after 12 months. One eye lost more than two lines. All other patients did not have any late side effects. CONCLUSION The one-year results of this new procedure are encouraging. Especially stability of the correction of myopia and myopic astigmatism with the SMILE procedure is very good.
Collapse
|
13
|
Five-year results of refractive lenticule extraction. J Cataract Refract Surg 2014; 40:1425-9. [DOI: 10.1016/j.jcrs.2014.01.034] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 12/18/2013] [Accepted: 01/07/2014] [Indexed: 11/24/2022]
|
14
|
[Morphological analysis of corneal refractive lenticules--is there a correlation with refractive results?]. Klin Monbl Augenheilkd 2014; 231:690-6. [PMID: 25036805 DOI: 10.1055/s-0034-1368608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
BACKGROUND ReLEx®flex is a corneal refractive procedure performed by removing corneal lenticules with a femtosecond (fs) laser system. Using electron microscopy, tissue parameters of extracted lenticules were analysed for potential correlations to the refractive results. Furthermore, the effect of previous contact lens (CL) wear on refractive stability (regression) was tested. PATIENTS AND METHODS 19 lenticules from 11 patients (age 24-56 years, 8 f, 3 m) were prepared for EM. The central areas of the samples were photographed and the distance between the collagen fibres and their diameters were digitally measured. ANOVA analysis was used to correlate postoperative refractional stability with time of preoperative CL use, fibre diameter and the coefficient of variation (CV) of fibre distance. RESULTS 14 of 19 lenticules were from patients who had worn CL preoperatively. The cumulative duration of CL wear averaged around 31.2 ± 35.5 thousand hours. Preoperative CL use significantly influenced the postoperative regression: the longer time patients had worn CL, the greater was the regression towards myopia (p = 0.01). Additionally, the morphological parameters collagen fibre diameter (p = 0.09) and CV of fibre distance (p = 0.07) had an impact on regression. CONCLUSIONS Prolonged CL use and alterations in ultrastructural patterns affected the refractive stability after ReLExflex. Although the pathophysiological relationships between CL use, corneal morphological parameters, and refractive stability are still poorly understood, these findings could potentially be used as prognostic markers for postoperative refraction after ReLExflex.
Collapse
|
15
|
Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis. Clin Ophthalmol 2013; 8:61-9. [PMID: 24368878 PMCID: PMC3869919 DOI: 10.2147/opth.s51200] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Femtosecond lasers have become the standard for laser-assisted in situ keratomileusis (LASIK) flap creation, but advanced mechanical microkeratomes are still an alternative, more cost-effective way to create the flap. The SCHWIND Carriazo-Pendular microkeratome is one of the most commonly used microkeratomes. The influence of different cutting parameters (head-advance speeds, cutting heads) on morphology of LASIK cuts was investigated. Setting Experimental study performed at the University Eye Hospital of the Martin Luther University Halle/Wittenberg, Halle (Saale), Germany. Methods The Carriazo-Pendular microkeratome was used on freshly enucleated porcine eyes for lamellar keratotomy. After flap removal, the cutting edge and stromal bed were evaluated from scanning electron micrographs using an individualized scoring system. Four different settings of microkeratome parameters were compared. For each setting, eight cuts were evaluated (n=32). Results Different oscillation frequencies and head-advance speeds did not influence the cutting qualities. A higher oscillation/feed rate ratio seemed to be advantageous for a smoother interface. Concerning different cuttings heads, a deeper keratotomy led to sharper cutting edges. The thinner the flap, the more irregularities in the stromal bed appeared. Complications did not occur. Conclusion The Carriazo-Pendular microkeratome is a safe tool with which to create a LASIK flap and is a good alternative to a costly femtosecond laser. Deeper keratotomies, as well as the use of a higher oscillation/feed rate quotient, improve the cutting quality.
Collapse
|
16
|
Reply: To PMID 23608569. J Cataract Refract Surg 2013; 39:1792-3. [PMID: 24160403 DOI: 10.1016/j.jcrs.2013.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
17
|
Reply: To PMID 23608569. J Cataract Refract Surg 2013; 39:1627. [PMID: 24075177 DOI: 10.1016/j.jcrs.2013.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2013] [Indexed: 10/26/2022]
|
18
|
Reply: To PMID 23608569. J Cataract Refract Surg 2013; 39:1628. [PMID: 24075180 DOI: 10.1016/j.jcrs.2013.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2013] [Indexed: 11/16/2022]
|
19
|
An in vitro study on focusing fs-laser pulses into ocular media for ophthalmic surgery. Lasers Surg Med 2013; 45:589-96. [PMID: 24105636 DOI: 10.1002/lsm.22179] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2013] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE To investigate femtosecond (fs)-laser patterns within ocular media for ophthalmic surgery. METHODS Vitreous and crystalline lens tissue from porcine eyes were treated with 2-dimensional fs-laser patterns and inspected under the optical microscope. Time resolved pump-probe experiments were conducted on vitreous tissue and gelatin, which should act as a model for crystalline lens tissue. RESULTS Within crystalline lens tissue, pulse overlap leads to the formation of large bubbles, which is caused by subsequent energy input from the surrounding plasma channel. This effect can be used for bubble size control. Vitreous tissue behaves similar to water under fs-laser treatment, but it still allows fs-laser cutting. CONCLUSION Bubble size control by laser bursts may reduce optical side-effects of fs-laser treatment. Furthermore, fs-laser treatment could be used for vitreoretinal applications.
Collapse
|
20
|
Aktuelle Trends in der Diagnostik des Trockenen Auges. Klin Monbl Augenheilkd 2012. [DOI: 10.1055/s-0032-1327174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
21
|
Analysis of optical side-effects of fs-laser therapy in human presbyopic lens simulated with modified contact lenses. Graefes Arch Clin Exp Ophthalmol 2012; 250:1813-25. [PMID: 22371023 DOI: 10.1007/s00417-012-1965-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2011] [Revised: 12/21/2011] [Accepted: 02/03/2012] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND In a single-blinded study, optical side-effects of a potential femtosecond (fs)-laser therapy in presbyopic human lenses were tested. Simulation of this therapy was carried out by applying fs-laser patterns into standard contact lenses (CL). METHODS In the first part of the study, the influence of the numerical aperture on optical side-effects was investigated by comparing a typical fs-LASIK configuration to a fs-presbyopia treatment (n = 11). The second part focused on a possible improvement of visual performance by comparing a regular grid pattern to a randomly chosen spacing of the laser spots (n = 16). Visual acuity was measured with ETDRS charts, contrast sensitivity with F.A.C.T. charts and mesopic vision with Mesotest II. Forward scattered light was measured with the C-Quant (both instruments: Oculus Optikgeräte GmbH, Germany). A questionnaire detected subjective quality of vision. Differences between laser-treated and untreated CL and among the modifications were analyzed. RESULTS The laser-treated and standard CL indicated no significant difference in visual acuity, contrast sensitivity and mesopic vision without glare. While wearing modified lenses with a regular grid, quality of vision decreased significantly by means of mesopic vision with glare and subjective straylight. These modifications also caused an impairment of subjective quality of vision. In contrast, there was no significant difference between the random pattern and standard CL. CONCLUSION The increase of optical side-effects was reproducibly dependent on the geometry of the laser-structure. A randomized grid induced the least limitation. The study results are useful for planning possible laser-patterns in fs-laser therapy of the presbyopic lens.
Collapse
|
22
|
Femtosecond laser treatment of the crystalline lens: a 1-year study of possible cataractogenesis in minipigs. Graefes Arch Clin Exp Ophthalmol 2011; 249:1567-73. [DOI: 10.1007/s00417-011-1772-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2011] [Revised: 05/04/2011] [Accepted: 07/28/2011] [Indexed: 10/17/2022] Open
|
23
|
Surface quality of human corneal lenticules after femtosecond laser surgery for myopia comparing different laser parameters. Graefes Arch Clin Exp Ophthalmol 2011; 249:1417-24. [DOI: 10.1007/s00417-010-1578-4] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2010] [Revised: 11/09/2010] [Accepted: 11/15/2010] [Indexed: 11/25/2022] Open
|
24
|
Surface Quality of Porcine Corneal Lenticules after Femtosecond Lenticule Extraction. Ophthalmic Res 2011; 46:107-12. [PMID: 21311205 DOI: 10.1159/000323814] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Accepted: 12/23/2010] [Indexed: 11/19/2022]
|
25
|
Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol 2010; 95:335-9. [PMID: 20601657 DOI: 10.1136/bjo.2009.174284] [Citation(s) in RCA: 549] [Impact Index Per Article: 39.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AIM This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. DESIGN Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. METHODS A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. MAIN OUTCOME MEASURES Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. RESULTS Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. CONCLUSION SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.
Collapse
|
26
|
Effect of a Suction Device for Femtosecond Laser on Anterior Chamber Depth and Crystalline Lens Position Measured by OCT. J Refract Surg 2009; 25:1005-11. [DOI: 10.3928/1081597x-20091016-06] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2008] [Accepted: 10/21/2008] [Indexed: 11/20/2022]
|
27
|
Dynamische akkommodative Aberrometrie mithilfe einer binokularen Stimulation. Klin Monbl Augenheilkd 2008. [DOI: 10.1055/s-2008-1058041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
28
|
Vermessung des Auges während der Akkommodation mittels optischer Kohärenztomografie (OCT). Klin Monbl Augenheilkd 2008. [DOI: 10.1055/s-2008-1058042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
29
|
Presbyopietherapie mit Femtosekundenlaser. Klin Monbl Augenheilkd 2008. [DOI: 10.1055/s-2008-1057985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
30
|
|
31
|
Goblet cell numbers and epithelial proliferation in the conjunctiva of patients with dry eye syndrome treated with cyclosporine. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 2002; 120:330-7. [PMID: 11879137 DOI: 10.1001/archopht.120.3.330] [Citation(s) in RCA: 230] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
OBJECTIVES To compare conjunctival goblet cell numbers as well as epithelial turnover in patients with non-Sjögren syndrome--associated keratoconjunctivitis sicca (NSS-KCS) and those with SS-KCS before and after 6 months of treatment with topical cyclosporine A (CsA) ophthalmic emulsion. METHODS Conjunctival biopsy specimens from 16 patients with NSS-KCS and 12 with SS-KCS were obtained at baseline and after 6 months' therapy with CsA or vehicle alone. Conjunctival biopsy specimens were also obtained from 11 normal subjects. Periodic acid--Schiff staining determined the number of goblet cells present. Immunofluorescence microscopy for Ki-67 localization was used to evaluate the number of actively cycling cells. RESULTS Periodic acid--Schiff staining showed fewer goblet cells at baseline in both dry eye populations when compared with normal subjects (P<.001). After 6 months of CsA treatment, conjunctival biopsy specimens of both NSS-KCS and SS-KCS groups revealed an increase in goblet cells compared with baseline (P<.05). More Ki-67--positive cells were observed in NSS-KCS conjunctiva at baseline than in normal conjunctiva (P<.05) whereas numbers of these cells in SS-KCS conjunctiva were similar to normal at baseline. After 6 months of CsA treatment, conjunctival biopsy specimens of NSS-KCS revealed a decrease in Ki-67--labeled cells compared with baseline (P<.001). In contrast, no substantial change was observed for CsA treatment in patients with SS-KCS. CONCLUSIONS Treatment of dry eye syndrome for 6 months with topical CsA resulted in an increase in goblet cell numbers in patients with NSS-KCS and SS-KCS and a decrease in epithelial turnover in those with NSS-KCS. Reducing ocular surface inflammation might have an effect on the proliferative activity of the epithelium.
Collapse
|
32
|
Alteration in goblet cell numbers and mucin gene expression in a mouse model of allergic conjunctivitis. Invest Ophthalmol Vis Sci 2001; 42:2483-9. [PMID: 11581187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023] Open
Abstract
PURPOSE To determine whether the number of filled conjunctival goblet cells and mucin gene expression are altered in a mouse model of allergic conjunctivitis. METHODS A/J mice were sensitized intraperitoneally with cat dander or the peptide P3-1 from the protein Fel d1. Two weeks later, the mice were challenged for 7 consecutive days with eye drops containing the allergens. Conjunctival tissue was harvested at 0, 6, 24, or 48 hours after final antigen challenge. Control samples were naïve animals and mice sensitized with cat dander and challenged with OVA-peptide or PBS. The mean number of filled goblet cells per square millimeter in three forniceal fields for each group was determined in wholemounts of conjunctiva prepared using rhodamine-phalloidin labeling followed by confocal microscopy. RNA was isolated from conjunctiva of the contralateral eye and taken for relative quantitation of mRNA of the goblet cell mucin Muc5AC and the epithelial membrane-spanning mucin Muc4, by real-time RT-PCR. RESULTS The number of filled goblet cells was significantly decreased with both cat dander and P3-1, after final ocular challenge (P < 0.001). The most significant decrease over naïve mice was seen at 6 hours after final challenge with both allergens. The number of filled goblet cells was still decreased but was returning toward naïve levels at 24 hours (P < 0.05), and at 48 hours no significant difference was seen compared with naïve, PBS-treated, and OVA-peptide-treated control samples. For both cat dander and P3-1, Muc5AC and Muc4 mRNA was found to be decreased at the time of final ocular challenge. The level of Muc5AC mRNA from goblet cells rebounded from the decrease to show an increase over control by 24 hours after final challenge, and by 48 hours, the mRNA level had returned to naïve control range. In contrast, significant increases in Muc5AC mRNA were evident after final control challenge with PBS or OVA-peptide, indicating a potential irritant effect of drop application. The Muc4 mRNA level was significantly reduced at all time points except 24 hours after the last challenge. By comparison with allergen-challenged eyes, no change in Muc4 message levels was noted at any time point in OVA-peptide- or PBS-treated control eyes. CONCLUSIONS These findings demonstrate that, in the conjunctiva of mice, repetitive application of allergens induces a reduction in the number of filled goblet cells and a decrease in Muc5AC and Muc4 mRNAs. After a period of 24 to 48 hours, the goblet cell number return to naïve levels, and goblet cell mucin mRNA levels return to above or within normal range, indicating a rapid recovery in the mucus secretion system.
Collapse
|
33
|
Abstract
The ocular surface shares many characteristics with mucosal surfaces. In both, healing is regulated by peptide growth factors, cytokines, and extracellular matrix proteins. However, these factors are not sufficient to ensure most rapid healing. Trefoil peptides are abundantly expressed epithelial cell products which exert protective effects and are key regulators of gastrointestinal epithelial restitution, the critical early phase of cell migration after mucosal injury. To assess the role of trefoil peptides in corneal epithelial wound healing, the effects of intestinal trefoil factor (ITF/TFF3) and spasmolytic polypeptide (SP/TFF2) on migration and proliferation of corneal epithelial cells were analyzed. Both ITF and SP enhanced restitution of primary rabbit corneal epithelial cells in vitro. While the restitution-enhancing effects of TGF-alpha and TGF-beta were both inhibited by neutralizing anti-TGF-beta-antibodies, trefoil peptide stimulation of restitution was not. Neither trefoil peptide significantly affected proliferation of primary corneal epithelial cells. ITF but not SP or pS2 mRNA was present in rabbit corneal and conjunctival tissues. In summary, the data indicate an unanticipated role of trefoil peptides in healing of ocular surface and demand rating their functional actions beyond the gastrointestinal tract.
Collapse
|
34
|
Analysis of topical cyclosporine treatment of patients with dry eye syndrome: effect on conjunctival lymphocytes. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 2000; 118:1489-96. [PMID: 11074805 DOI: 10.1001/archopht.118.11.1489] [Citation(s) in RCA: 251] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
OBJECTIVE To study the effect of topical cyclosporine on lymphocyte activation within the conjunctiva of patients with moderate to severe dry eye syndrome (Sjögren and non-Sjögren). METHODS Biopsy specimens were obtained at baseline and after 6 months of cyclosporine treatment from eyes of 32 patients with moderate to severe dry eye syndrome; 19 were cyclosporine treated (0.05% cyclosporine, n = 13; 0.1% cyclosporine, n = 6) and 13 were vehicle treated. Within this group there were 12 with Sjögren syndrome and 20 with non-Sjögren syndrome. Biopsy tissue was analyzed using immunohistochemical localization of binding of monoclonal antibodies to lymphocytic markers CD3, CD4, and CD8 as well as lymphocyte activation markers CD11a and HLA-DR. RESULTS In cyclosporine-treated eyes, biopsy results of conjunctivae showed decreases in the number of cells positive for CD3, CD4, and CD8, while in vehicle-treated eyes, results showed increases in these markers, although these differences were not statistically significant. Following treatment with 0.05% cyclosporine, there was a significant decrease in the number of cells expressing the lymphocyte activation markers CD11a (P<.05) and HLA-DR (P<.05), indicating less activation of lymphocytes as compared with vehicle treatment. Within the Sjögren patient subgroup, those treated with 0.05% cyclosporine also showed a significant decrease in the number of cells positive for CD11a (P<.001) as well as CD3 (P<.03), indicating a reduction in number of activated lymphocytes. CONCLUSION Treatment of dry eye syndrome with topical cyclosporine significantly reduced the numbers of activated lymphocytes within the conjunctiva. Arch Ophthalmol. 2000;118:1489-1496
Collapse
|
35
|
The effects of human tear electrolytes on the viability and hydrogel colonization of Pseudomonas aeruginosa and Staphylococcus aureus. J Ind Microbiol Biotechnol 2000. [DOI: 10.1038/sj.jim.7000016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
36
|
Abstract
The purpose of this study was to evaluate the presence of interleukin-6 (IL-6) in basal tears of contact lens wearers (n = 18) and nonlens wearers (n = 25). Samples (5 microl) were collected with a microcapillary pipette and evaluated using PAGE electrophoresis and immunoblot analysis. Contact lens-wearing patients had a mean IL-6 level of 43.8 +/- 5.3 pg/5 microl compared with nondetectable IL-6 levels throughout the noncontact lens-wearing population. IL-6 in several patients removed from contact lens wear for 6 days became nondetectable. When these patients were returned to wearing lenses, IL-6 levels increased to their original levels within 24 h. The data presented indicate that an ocular medical device may stimulate IL-6 production.
Collapse
|
37
|
Abstract
PURPOSE There is evidence that microglial activation occurs with normal aging in some regions of the brain of rodents. We investigated the pattern of microglia in the retinas of young and aged quail and pigeons to determine if age-related retinal changes evoked migration of microglia into the outer retina. In quail we also investigated the correlation between activated microglia and age-related photoreceptor loss. METHODS Microglia were identified with the monoclonal antibody QH1 in cryosectioned eyes from pigeons, ages 2 to 20 years (n = 14), and in paraffin sections from six-month (n = 15) and one-year-old quail (n = 30). Rounded microglia in the photoreceptor layer were counted in consecutive 400x fields from temporal to nasal. Photoreceptor counts were made from 10 quail retina flat mounts. The photoreceptor number was compared to the number of microglia in corresponding regions of the same retina. RESULTS Rounded microglia were detected among the photoreceptors of pigeons and quail. Significantly more of these microglia were found in peripheral than in central regions close to the pecten (pigeon p < 0.002 and quail p < 0.01). Furthermore, more microglial cells were present among peripheral photoreceptors of older quail (p < 0.03) and pigeons (p < 0.05) than in the younger birds. In the peripheral retina of the older quail, microglia were significantly and inversely related to the number of photoreceptors (r2 = 0.9; p < 0.001). CONCLUSIONS Increased microglial were observed in the peripheral retina of both old quail and old pigeons. In the quail, the rounded (activated) microglia were distributed preferentially in regions of greatest photoreceptor loss. Microglial activation does not appear to be a general phenomenon of the aging retina, but in quail activation appears directly related to photoreceptor loss. It is unclear at this time how the change in microglia shape and distribution is related to their neuroprotective / neurotoxic potential.
Collapse
|