1
|
Search for Antideuterons of Cosmic Origin Using the BESS-Polar II Magnetic-Rigidity Spectrometer. PHYSICAL REVIEW LETTERS 2024; 132:131001. [PMID: 38613296 DOI: 10.1103/physrevlett.132.131001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 10/21/2023] [Accepted: 01/10/2024] [Indexed: 04/14/2024]
Abstract
We searched for antideuterons (d[over ¯]'s) in the 4.7×10^{9} cosmic-ray events observed during the BESS-Polar II flight at solar minimum in 2007-2008 but found no candidates. The resulting 95% C.L. upper limit on the d[over ¯] flux is 6.7×10^{-5} (m^{2} s sr GeV/n)^{-1} in an energy range from 0.163 to 1.100 GeV/n. The result has improved by more than a factor of 14 from the upper limit of BESS97, which had a potential comparable to that of BESS-Polar II in the search for cosmic-origin d[over ¯]'s and was conducted during the former solar minimum. The upper limit of d[over ¯] flux from BESS-Polar II is the first result achieving the sensitivity to constrain the latest theoretical predictions.
Collapse
|
2
|
Acceleration and transport of relativistic electrons in the jets of the microquasar SS 433. Science 2024; 383:402-406. [PMID: 38271522 DOI: 10.1126/science.adi2048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 12/04/2023] [Indexed: 01/27/2024]
Abstract
SS 433 is a microquasar, a stellar binary system that launches collimated relativistic jets. We observed SS 433 in gamma rays using the High Energy Stereoscopic System (H.E.S.S.) and found an energy-dependent shift in the apparent position of the gamma-ray emission from the parsec-scale jets. These observations trace the energetic electron population and indicate that inverse Compton scattering is the emission mechanism of the gamma rays. Our modeling of the energy-dependent gamma-ray morphology constrains the location of particle acceleration and requires an abrupt deceleration of the jet flow. We infer the presence of shocks on either side of the binary system, at distances of 25 to 30 parsecs, and that self-collimation of the precessing jets forms the shocks, which then efficiently accelerate electrons.
Collapse
|
3
|
Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the TeV Region with CALET on the International Space Station. PHYSICAL REVIEW LETTERS 2023; 131:191001. [PMID: 38000434 DOI: 10.1103/physrevlett.131.191001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/31/2023] [Accepted: 10/09/2023] [Indexed: 11/26/2023]
Abstract
Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10^{5}), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from -3.15 to -3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.
Collapse
|
4
|
Erratum: Charge-Sign Dependent Cosmic-Ray Modulation Observed with the Calorimetric Electron Telescope on the International Space Station [Phys. Rev. Lett. 130, 211001 (2023)]. PHYSICAL REVIEW LETTERS 2023; 131:109902. [PMID: 37739390 DOI: 10.1103/physrevlett.131.109902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Indexed: 09/24/2023]
Abstract
This corrects the article DOI: 10.1103/PhysRevLett.130.211001.
Collapse
|
5
|
Whole-genome sequencing analysis of molecular epidemiology and silent transmissions causing meticillin-resistant Staphylococcus aureus bloodstream infections in a university hospital. J Hosp Infect 2023; 139:141-149. [PMID: 37301229 DOI: 10.1016/j.jhin.2023.05.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/25/2023] [Accepted: 05/26/2023] [Indexed: 06/12/2023]
Abstract
BACKGROUND The emergence of novel genomic-type clones, such as community-associated meticillin-resistant Staphylococcus aureus (MRSA) and livestock-associated MRSA, and their invasion into hospitals have become major concerns worldwide; however, little information is available regarding the prevalence of MRSA in Japan. Whole-genome sequencing (WGS) has been conducted to analyse various pathogens worldwide. Therefore, it is important to establish a genome database of clinical MRSA isolates available in Japan. AIM A molecular epidemiological analysis of MRSA strains isolated from bloodstream-infected patients in a Japanese university hospital was conducted using WGS and single-nucleotide polymorphism (SNP) analysis. Additionally, through a review of patients' clinical characteristics, the effectiveness of SNP analysis as a tool for detecting silent nosocomial transmission that may be missed by other methods was evaluated in diverse settings and various time points of detection. METHODS Polymerase-chain-reaction-based staphylococcal cassette chromosome mec (SCCmec) typing was performed using 135 isolates obtained between 2014 and 2018, and WGS was performed using 88 isolates obtained between 2015 and 2017. FINDINGS SCCmec type II strains, prevalent in 2014, became rare in 2018, whereas the prevalence of SCCmec type IV strains increased from 18.75% to 83.87% of the population, and became the dominant clones. Clonal complex (CC) 5 CC8 and CC1 were detected between 2015 and 2017, with CC1 being dominant. In 88 cases, SNP analyses revealed nosocomial transmissions among 20 patients which involved highly homologous strains. CONCLUSIONS Routine monitoring of MRSA by whole-genome analysis is effective not only for gaining knowledge regarding molecular epidemiology, but also for detecting silent nosocomial transmission.
Collapse
|
6
|
Charge-Sign Dependent Cosmic-Ray Modulation Observed with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2023; 130:211001. [PMID: 37295105 DOI: 10.1103/physrevlett.130.211001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 03/16/2023] [Accepted: 04/13/2023] [Indexed: 06/12/2023]
Abstract
We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the Calorimetric Electron Telescope onboard the International Space Station over 6 yr, corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the Calorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical "drift model" of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.
Collapse
|
7
|
Direct Measurement of the Cosmic-Ray Helium Spectrum from 40 GeV to 250 TeV with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2023; 130:171002. [PMID: 37172251 DOI: 10.1103/physrevlett.130.171002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 04/03/2023] [Indexed: 05/14/2023]
Abstract
We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015, to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed for the collection of helium data over a large energy interval, from ∼40 GeV to ∼250 TeV, for the first time with a single instrument in low Earth orbit. The measured spectrum shows evidence of a deviation of the flux from a single power law by more than 8σ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, and DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A double broken power law is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV/n to about 60 TeV/n is also presented, using the CALET proton flux recently updated with higher statistics.
Collapse
|
8
|
Cosmic-Ray Boron Flux Measured from 8.4 GeV/n to 3.8 TeV/n with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2022; 129:251103. [PMID: 36608255 DOI: 10.1103/physrevlett.129.251103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 11/07/2022] [Accepted: 11/22/2022] [Indexed: 06/17/2023]
Abstract
We present the measurement of the energy dependence of the boron flux in cosmic rays and its ratio to the carbon flux in an energy interval from 8.4 GeV/n to 3.8 TeV/n based on the data collected by the Calorimetric Electron Telescope (CALET) during ∼6.4 yr of operation on the International Space Station. An update of the energy spectrum of carbon is also presented with an increase in statistics over our previous measurement. The observed boron flux shows a spectral hardening at the same transition energy E_{0}∼200 GeV/n of the C spectrum, though B and C fluxes have different energy dependences. The spectral index of the B spectrum is found to be γ=-3.047±0.024 in the interval 25<E<200 GeV/n. The B spectrum hardens by Δγ_{B}=0.25±0.12, while the best fit value for the spectral variation of C is Δγ_{C}=0.19±0.03. The B/C flux ratio is compatible with a hardening of 0.09±0.05, though a single power-law energy dependence cannot be ruled out given the current statistical uncertainties. A break in the B/C ratio energy dependence would support the recent AMS-02 observations that secondary cosmic rays exhibit a stronger hardening than primary ones. We also perform a fit to the B/C ratio with a leaky-box model of the cosmic-ray propagation in the Galaxy in order to probe a possible residual value λ_{0} of the mean escape path length λ at high energy. We find that our B/C data are compatible with a nonzero value of λ_{0}, which can be interpreted as the column density of matter that cosmic rays cross within the acceleration region.
Collapse
|
9
|
Search for Dark Matter Annihilation Signals in the H.E.S.S. Inner Galaxy Survey. PHYSICAL REVIEW LETTERS 2022; 129:111101. [PMID: 36154418 DOI: 10.1103/physrevlett.129.111101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 01/17/2022] [Accepted: 07/13/2022] [Indexed: 06/16/2023]
Abstract
The central region of the Milky Way is one of the foremost locations to look for dark matter (DM) signatures. We report the first results on a search for DM particle annihilation signals using new observations from an unprecedented γ-ray survey of the Galactic Center (GC) region, i.e., the Inner Galaxy Survey, at very high energies (≳100 GeV) performed with the H.E.S.S. array of five ground-based Cherenkov telescopes. No significant γ-ray excess is found in the search region of the 2014-2020 dataset and a profile likelihood ratio analysis is carried out to set exclusion limits on the annihilation cross section ⟨σv⟩. Assuming Einasto and Navarro-Frenk-White (NFW) DM density profiles at the GC, these constraints are the strongest obtained so far in the TeV DM mass range. For the Einasto profile, the constraints reach ⟨σv⟩ values of 3.7×10^{-26} cm^{3} s^{-1} for 1.5 TeV DM mass in the W^{+}W^{-} annihilation channel, and 1.2×10^{-26} cm^{3} s^{-1} for 0.7 TeV DM mass in the τ^{+}τ^{-} annihilation channel. With the H.E.S.S. Inner Galaxy Survey, ground-based γ-ray observations thus probe ⟨σv⟩ values expected from thermal-relic annihilating TeV DM particles.
Collapse
|
10
|
Observation of Spectral Structures in the Flux of Cosmic-Ray Protons from 50 GeV to 60 TeV with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2022; 129:101102. [PMID: 36112450 DOI: 10.1103/physrevlett.129.101102] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/19/2022] [Accepted: 08/03/2022] [Indexed: 06/15/2023]
Abstract
A precise measurement of the cosmic-ray proton spectrum with the Calorimetric Electron Telescope (CALET) is presented in the energy interval from 50 GeV to 60 TeV, and the observation of a softening of the spectrum above 10 TeV is reported. The analysis is based on the data collected during ∼6.2 years of smooth operations aboard the International Space Station and covers a broader energy range with respect to the previous proton flux measurement by CALET, with an increase of the available statistics by a factor of ∼2.2. Above a few hundred GeV we confirm our previous observation of a progressive spectral hardening with a higher significance (more than 20 sigma). In the multi-TeV region we observe a second spectral feature with a softening around 10 TeV and a spectral index change from -2.6 to -2.9 consistently, within the errors, with the shape of the spectrum reported by DAMPE. We apply a simultaneous fit of the proton differential spectrum which well reproduces the gradual change of the spectral index encompassing the lower energy power-law regime and the two spectral features observed at higher energies.
Collapse
|
11
|
64P Phase I/II study of nivolumab plus lenvatinib for advanced biliary tract cancer (JCOG1808/NCCH1817, SNIPE). Ann Oncol 2022. [DOI: 10.1016/j.annonc.2022.07.092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
12
|
Polymeric Hydrogelator-Based Molecular Gels Containing Polyaniline/Phosphoric Acid Systems. Gels 2022; 8:gels8080469. [PMID: 35892728 PMCID: PMC9332760 DOI: 10.3390/gels8080469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 07/21/2022] [Accepted: 07/25/2022] [Indexed: 02/04/2023] Open
Abstract
To expand the range of applications of hydrogels, researchers are interested in developing novel molecular hydrogel materials that have affinities for the living body and the ability to mediate electrical signals. In this study, a simple mixing method for creating a novel composite molecular gel is employed, which combines a hydrophilic conductive polymer, a polyaniline/phosphoric acid complex, and a polymer hydrogelator as a matrix. The composite hydrogel showed an improved gel-forming ability; more effective mechanical properties, with an increased strain value at the sol-gel transition point compared to the single system, which may be sufficient for paintable gel; and a better electrochemical response, due to the electrically conducting polyaniline component. These findings demonstrate the applicability of the new composite hydrogels to new potential paintable electrode materials.
Collapse
|
13
|
Continuous partially hydrolyzed guar gum intake reduces cold-like symptoms: a randomized, placebo-controlled, double-blinded trial in healthy adults. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2022; 26:5154-5163. [PMID: 35916813 DOI: 10.26355/eurrev_202207_29304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
OBJECTIVE Partially hydrolyzed guar gum (PHGG), a water-soluble dietary fiber produced by the controlled partial enzymatic hydrolysis of guar gum beans, has various physiological roles. PHGG is expected to influence the immune function and prevent infections. The objective of this study was to examine the effect of continuous ingestion of PHGG for 12 weeks on the development of cold-like symptoms. PATIENTS AND METHODS A placebo-controlled, double blind, randomized, parallel-group comparative study was conducted. 96 healthy Japanese adults received 5.2 g PHGG or placebo daily for 12 weeks. Cold-like symptoms were assessed based on patient diary, and the levels of short-chain fatty acids (SCFAs) in stool and blood immune markers at baseline and at weeks 6 and 12. RESULTS The cumulative number of "no symptoms" days for all symptoms was significantly larger in the PHGG than in the placebo group. The result of the analysis by severity of cold-like symptoms also showed significant differences, with the PHGG group having a lower severity of cold-like symptoms. Propionic acid at weeks 6 and 12 and n-butyric acid and total SCFAs at week 12 were significantly higher in the PHGG than in the placebo group. The Interferon-γ level was significantly lower at week 6 in the PHGG than in the placebo group. CONCLUSIONS PHGG intake may affect immune function and suppress cold-like symptoms through the production of SCFAs in healthy adults.
Collapse
|
14
|
Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI. AJNR Am J Neuroradiol 2022; 43:972-977. [PMID: 35738672 DOI: 10.3174/ajnr.a7561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Accepted: 05/06/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND AND PURPOSE Patients with cerebral aneurysms often undergo MR imaging after microsurgical clipping. Ultra-high-field MR imaging at 7T may provide high diagnostic capability in such clinical situations. However, titanium alloy clips have safety issues such as adverse interactions with static magnetic fields and radiofrequency-induced heating during 7T MR imaging. The purpose of this study was to quantitatively assess temperature increases on various types of titanium alloy aneurysm clips during 7T MR imaging. MATERIALS AND METHODS Five types of titanium alloy aneurysm clips were tested, including combinations of short, long, straight, angled, and fenestrated types. Each clip was set in a phantom filled with gelled saline mixed with polyacrylic acid and underwent 7T MR imaging with 3D T1WI with a spoiled gradient recalled acquisition in the steady-state technique. Temperature was chronologically measured at the tips of the clip blade and head, angled part of the clip, and 5 mm from the tip of the clip head using MR imaging-compatible fiber-optic thermometers. RESULTS Temperature increases at all locations for right-angled and short straight clips were <1°C. Temperature increases at the angled part for the 45° angled clip and the tip of the clip head for the straight fenestrated clip were >1°C. Temperature increases at all locations for the long straight clip were >2°C. CONCLUSIONS Temperature increases on the right-angled and short straight clips remained below the regulatory limit during 7T MR imaging, but temperature increases on the 45° angled, straight fenestrated, and long straight clips exceeded this limit.
Collapse
|
15
|
Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/n to 240 GeV/n with CALET on the International Space Station. PHYSICAL REVIEW LETTERS 2022; 128:131103. [PMID: 35426700 DOI: 10.1103/physrevlett.128.131103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/03/2022] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ∼3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The particle's energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [1O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).PRLTAO0031-900710.1103/PhysRevLett.126.241101], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51±0.07.
Collapse
|
16
|
Abstract
Recurrent novae are repeating thermonuclear explosions in the outer layers of white dwarfs, due to the accretion of fresh material from a binary companion. The shock generated when ejected material slams into the companion star's wind can accelerate particles. We report very-high-energy (VHE, [Formula: see text]) gamma rays from the recurrent nova RS Ophiuchi, up to a month after its 2021 outburst, observed using the High Energy Stereoscopic System. The VHE emission has a similar temporal profile to lower-energy GeV emission, indicating a common origin, with a two-day delay in peak flux. These observations constrain models of time-dependent particle energization, favoring a hadronic emission scenario over the leptonic alternative. Shocks in dense winds provide favorable environments for efficient acceleration of cosmic-rays to very high energies.
Collapse
|
17
|
Bayesian inference of ion velocity distribution function from laser-induced fluorescence spectra. Sci Rep 2021; 11:20810. [PMID: 34675232 PMCID: PMC8531337 DOI: 10.1038/s41598-021-00138-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 10/06/2021] [Indexed: 11/21/2022] Open
Abstract
The velocity distribution function is a statistical description that connects particle kinetics and macroscopic parameters in many-body systems. Laser-induced fluorescence (LIF) spectroscopy is utilized to measure the local velocity distribution function in spatially inhomogeneous plasmas. However, the analytic form of such a function for the system of interest is not always clear under the intricate factors in non-equilibrium states. Here, we propose a novel approach to select the valid form of the velocity distribution function based on Bayesian statistics. We formulate the Bayesian inference of ion velocity distribution function and apply it to LIF spectra locally observed at several positions in a linear magnetized plasma. We demonstrate evaluating the spatial inhomogeneity by verifying each analytic form of the local velocity distribution function. Our approach is widely applicable to experimentally establish the velocity distribution function in plasmas and fluids, including gases and liquids.
Collapse
|
18
|
FSHD. Neuromuscul Disord 2021. [DOI: 10.1016/j.nmd.2021.07.192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
19
|
CONGENITAL MUSCULAR DYSTROPHIES. Neuromuscul Disord 2021. [DOI: 10.1016/j.nmd.2021.07.089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
20
|
[Chemo-Resistant Breast Carcinoma with Cartilaginous Differentiation Manifestation after Neoadjuvant Chemotherapy-A Case Report]. Gan To Kagaku Ryoho 2021; 48:951-953. [PMID: 34267034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
A 49-year-old woman was admitted to our hospital because of a tumor in her right breast. The tumor was localized to the C area and was approximately 3 cm in size. A right axillary lymphadenopathy was also found. Histopathological examination and needle biopsy of the breast tumor revealed invasive lobular carcinoma, and she was diagnosed with Stage ⅡB triple-negative breast cancer(cT2N1M0). Paclitaxel plus bevacizumab chemotherapy followed by ddAC chemotherapy was administered as neoadjuvant chemotherapy, but the tumor remained stable. Thus, she underwent mastectomy and lymph node dissection. Pathological findings of the resected specimen showed invasive carcinoma with cartilaginous differentiation. She was then treated with capecitabine 15 days after the surgery; however, multiple lung metastases were found on CT after 6 courses. Therefore, she was transferred to another hospital and received other chemotherapies, but died after 5 months.
Collapse
|
21
|
Measurement of the Iron Spectrum in Cosmic Rays from 10 GeV/n to 2.0 TeV/n with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2021; 126:241101. [PMID: 34213922 DOI: 10.1103/physrevlett.126.241101] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/24/2021] [Accepted: 04/12/2021] [Indexed: 06/13/2023]
Abstract
The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this Letter a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10 GeV/n to 2.0 TeV/n allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV/n to 2 TeV/n our present data are compatible with a single power law with spectral index -2.60±0.03.
Collapse
|
22
|
Revealing x-ray and gamma ray temporal and spectral similarities in the GRB 190829A afterglow. Science 2021; 372:1081-1085. [PMID: 34083487 DOI: 10.1126/science.abe8560] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 04/07/2021] [Indexed: 11/02/2022]
Abstract
Gamma-ray bursts (GRBs), which are bright flashes of gamma rays from extragalactic sources followed by fading afterglow emission, are associated with stellar core collapse events. We report the detection of very-high-energy (VHE) gamma rays from the afterglow of GRB 190829A, between 4 and 56 hours after the trigger, using the High Energy Stereoscopic System (H.E.S.S.). The low luminosity and redshift of GRB 190829A reduce both internal and external absorption, allowing determination of its intrinsic energy spectrum. Between energies of 0.18 and 3.3 tera-electron volts, this spectrum is described by a power law with photon index of 2.07 ± 0.09, similar to the x-ray spectrum. The x-ray and VHE gamma-ray light curves also show similar decay profiles. These similar characteristics in the x-ray and gamma-ray bands challenge GRB afterglow emission scenarios.
Collapse
|
23
|
Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease. AJNR Am J Neuroradiol 2021; 42:1403-1409. [PMID: 34016589 DOI: 10.3174/ajnr.a7167] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 03/11/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Adult patients with ischemic Moyamoya disease are advised to undergo selective revascularization surgery based on cerebral hemodynamics. The purpose of this study was to determine the diagnostic accuracy of arterial spin-labeling MR imaging using Hadamard-encoded multiple postlabeling delays for the detection of reduced CBF in such patients. MATERIALS AND METHODS Thirty-seven patients underwent brain perfusion SPECT and pseudocontinuous arterial spin-labeling MR imaging using standard postlabeling delay (1525 ms) and Hadamard-encoded multiple postlabeling delays. For Hadamard-encoded multiple postlabeling delays, based on data obtained from the 7 sub-boluses with combinations of different labeling durations and postlabeling delays, CBF corrected by the arterial transit time was calculated on a voxel-by-voxel basis. Using a 3D stereotaxic template, we automatically placed ROIs in the ipsilateral cerebellar hemisphere and 5 MCA territories in the symptomatic cerebral hemisphere; then, the ratio of the MCA to cerebellar ROI was calculated. RESULTS The area under the receiver operating characteristic curve for detecting reduced SPECT-CBF ratios (<0.686) was significantly greater for the Hadamard-encoded multiple postlabeling delays-CBF ratios (0.885) than for the standard postlabeling delay-CBF ratios (0.786) (P = .001). The sensitivity and negative predictive value for the Hadamard-encoded multiple postlabeling delays-CBF ratios were 100% (95% confidence interval, 100%-100%) and significantly higher than the sensitivity (95% CI, 44%-80%) and negative predictive value (95% CI, 88%-97%) for the standard postlabeling delay-CBF ratio, respectively. CONCLUSIONS ASL MR imaging using Hadamard-encoded multiple postlabeling delays may be applicable as a screening tool because it can detect reduced CBF on brain perfusion SPECT with 100% sensitivity and a 100% negative predictive value in adult patients with ischemic Moyamoya disease.
Collapse
|
24
|
Study of the K_{L}→π^{0}νν[over ¯] Decay at the J-PARC KOTO Experiment. PHYSICAL REVIEW LETTERS 2021; 126:121801. [PMID: 33834796 DOI: 10.1103/physrevlett.126.121801] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 02/18/2021] [Indexed: 06/12/2023]
Abstract
The rare decay K_{L}→π^{0}νν[over ¯] was studied with the dataset taken at the J-PARC KOTO experiment in 2016, 2017, and 2018. With a single event sensitivity of (7.20±0.05_{stat}±0.66_{syst})×10^{-10}, three candidate events were observed in the signal region. After unveiling them, contaminations from K^{±} and scattered K_{L} decays were studied, and the total number of background events was estimated to be 1.22±0.26. We conclude that the number of observed events is statistically consistent with the background expectation. For this dataset, we set an upper limit of 4.9×10^{-9} on the branching fraction of K_{L}→π^{0}νν[over ¯] at the 90% confidence level.
Collapse
|
25
|
Direct Measurement of the Cosmic-Ray Carbon and Oxygen Spectra from 10 GeV/n to 2.2 TeV/n with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2020; 125:251102. [PMID: 33416351 DOI: 10.1103/physrevlett.125.251102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 09/01/2020] [Accepted: 11/19/2020] [Indexed: 06/12/2023]
Abstract
In this paper, we present the measurement of the energy spectra of carbon and oxygen in cosmic rays based on observations with the Calorimetric Electron Telescope on the International Space Station from October 2015 to October 2019. Analysis, including the detailed assessment of systematic uncertainties, and results are reported. The energy spectra are measured in kinetic energy per nucleon from 10 GeV/n to 2.2 TeV/n with an all-calorimetric instrument with a total thickness corresponding to 1.3 nuclear interaction length. The observed carbon and oxygen fluxes show a spectral index change of ∼0.15 around 200 GeV/n established with a significance >3σ. They have the same energy dependence with a constant C/O flux ratio 0.911±0.006 above 25 GeV/n. The spectral hardening is consistent with that measured by AMS-02, but the absolute normalization of the flux is about 27% lower, though in agreement with observations from previous experiments including the PAMELA spectrometer and the calorimetric balloon-borne experiment CREAM.
Collapse
|
26
|
Differential expression levels of CD151 enable enrichment of atrial cardiomyocytes derived from human induced-pluripotent stem cell. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.3579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
Human iPSCs-derived cardiomyocytes (hiPSCs-CMs) are heterogeneous populations that contain ventricular-like CMs (VCMs), atrial-like CMs (ACMs) and pacemaker cells. Isolation of pure populations of each hiPSCs-CM subtype corresponding to the target regions of the heart enables effective drug screening process and stable engraftment of hiPSCs-CMs (e.g. ventricular cardiomyocytes without impurities).
Purpose
Atrial and ventricular cardiomyocytes develop from distinct mesoderm populations, and many of different genes are expressed between two subtypes. Since our method of cardiomyocytes differentiation from hiPSCs mimics in vivo cardiomyocytes development, we hypothesized that two subtypes could be separated by differentially expressed genes in hiPSCs-CMs differentiation process. In this study, we focused cell surface genes which are useful for analysis by flow cytometry, and then identified cell surface marker that can distinguish atrial and ventricular cardiomyocytes from hiPSCs-CMs.
Methods
We performed an antibody-based screening using hiPSCs-CMs induced under atrial induction condition (AIC) and ventricular induction condition (VIC) by flow cytometry. To identify cell surface markers which enable discrimination of cardiac subtypes, we isolated the cell populations using the antibodies against the cell surface markers. Quantitative PCR was performed to analyze expression levels of subtype-specific genes in sorted cells. We confirmed subtype classification of cells using patch-clamp method.
Results
We identified CD151 as a novel candidate of atrial/ventricular selectable marker. The expression level of CD151 was low in most hiPSCs-CMs under AIC. In these cells, CD151-low cells highly expressed atrial genes compared to CD151-high cells. In contrast, the expression level of CD151 was high in most hiPSCs-CMs under VIC. In these cells, CD151-high cells highly expressed ventricular genes compared to CD151-low cells. Furthermore, we investigated the electrophysiological properties of CD151-high and -low cells using patch-clamp experiments. As expected, the cells showing atrial type action potential were enriched in AIC with low expression of CD151 (n=17). On the other hand, CD151-high cells (n=16) contained no atrial CMs, but mostly nodal like cells. In addition, CD151-low cells in AIC were affected with action potential duration by exposure of atrial specific channel blocker (4-aminopyridine) and activator (carbachol). In VIC, CD151-high cells (n=16) demonstrated ventricular type action potential property compared to CD151-low cells (n=21).
Conclusion
These results suggest that CD151 is a useful marker which can enrich ACMs from hiPSCs-CMs. Because these enriched ACMs are uniform population, it may be appropriate for atrial-selective drug screening. Additionally, this marker can reduce contaminated ACMs from hiPSCs-CMs cultured in VIC.
Action potential of CD151-high/low CMs
Funding Acknowledgement
Type of funding source: Other. Main funding source(s): Takeda pharmaceutical company limited, Japan society for the promotion of science(JSPS) KAKENHI
Collapse
|
27
|
Development of matured hiPSCs-derived 3D cardiac tissue using ERR gamma agonist and mechanical stress and application for Hypertrophic Cardiomyopathy (HCM) model. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.3668] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
Tissue engineering using human induced pluripotent stem cells-derived cardiomyocytes (hiPSCs-CMs) is one of the potential tools to replicate human heart in vitro. Although there are many publications on 3 dimensional (3D) heart tissues (1), these tissues show fetal like phenotypes. For that reason, several maturation methods such as electrical stimulation and mechanical stress have been investigated (2, 3). However, these methods have been inadequate in differentiating fetal like phenotype tissue from adult tissues. Previously, we identified a novel compound, T112, which induced hiPSCs-CMs maturation from approximately 9,000 compounds using Troponin I1-EmGFP and Troponin I3-mCherry double reporter hiPSCs-CMs. This compound enhanced morphological and metabolic maturation of hiPSCs-CMs via estrogen-rerated receptor gamma activation
Purpose
We hypothesized that our novel compound, T112, in combination with mechanical stress could result in further maturation of 3D heart tissue. Therefore, our specific aim is to develop a novel maturation method applicable to genetic disease model of HCM using 3D heart tissue combined with T112.
Methods
We constructed 3D heart tissue mixed with fibroblast and double reporter hiPSCs-CMs by the hydrogel methods using Flex cell system®. We added T112 with or without mechanical stretching to 3D tissue from 7 to 15 days after 3D heart tissue was constructed. Then we measured maturation related phenotype such as sarcomere gene expression, mitochondrial DNA content and cell size.
Results
Similar to hiPSCs-CM, the addition of T112 to the constructed 3D heart tissue significantly increased TNNI3 mRNA compared to that of DMSO. Furthermore, T112 treated 3D heart tissue showed increased cell size and oblong shape. Next, in order to promote more maturation of 3D heart tissue, we performed mechanical stretching with the addition of T112. The combination of T112 with mechanical stretching showed higher expression of mCherry, a reporter protein for TNNI3 expression, and higher isotropy of sarcomere alignment in 3D heart tissue than that with the static condition. Furthermore, 3D heart tissue in the treatment of T112 with or without mechanical stretching showed higher mitochondrial DNA content compared to the respective DMSO controls. Interestingly, we applied this combination method to hiPSCs carrying MYH7 R719Q mutation which is known to cause hypertrophic cardiomyopathy, and the 3D heart tissue composed of cardiomyocytes derived from mutant iPSCs demonstrated increased sarcomere disarray compared to isogenic wild-type 3D heart tissue.
Conclusion
These results suggest that the combination of T112 and mechanical stretching promotes metabolic and structural maturation of 3D heart tissue and would be useful for creating a HCM disease model.
Funding Acknowledgement
Type of funding source: Private company. Main funding source(s): T-CiRA project, Takeda Pharmaceutical Company Limited
Collapse
|
28
|
REGISTRIES, CARE, QUALITY OF LIFE, MANAGEMENT OF NMD. Neuromuscul Disord 2020. [DOI: 10.1016/j.nmd.2020.08.333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
29
|
New MRI Findings in Fukuyama Congenital Muscular Dystrophy: Brain Stem and Venous System Anomalies. AJNR Am J Neuroradiol 2020; 41:1094-1098. [PMID: 32439644 DOI: 10.3174/ajnr.a6577] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 04/03/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Leptomeningeal glioneuronal heterotopia of the brain stem and cerebral migration abnormality were pathologically reported in Fukuyama congenital muscular dystrophy, but the radiologic assessments of the brain stem and cerebral venous system (which may be involved in the development of the anomaly) were insufficient. Here, we evaluated the brain stem and cerebral veins on MR imaging in patients with Fukuyama congenital muscular dystrophy. MATERIALS AND METHODS We retrospectively reviewed the MR imaging findings of 27 patients with Fukuyama congenital muscular dystrophy. We visually assessed the hypoplasia, superficial structures, and signal intensity of the brain stem on T2WI, FLAIR, and double inversion recovery images and the cerebral, superficial, and deep veins with and without hemorrhage on T2WI and SWI. RESULTS Brain stem fluffy structures were seen in 96.3% of the cases on T2WI. Superficial high signal intensity on T2WI and FLAIR images was seen in 96.3% and 92.6%, respectively. Abnormally located superficial vessels beneath the cortex were seen in 11.1% on T2WI. Hypoplasia of the superficial cerebral veins was noted in all patients who underwent SWI. Dilated and tortuous subependymal veins were seen in 40.0% on SWI. Hemorrhages were seen in 11.1% on T2WI and in 60.0% on SWI. CONCLUSIONS Superficial brain stem structural and signal abnormalities would be useful MR imaging findings to diagnose Fukuyama congenital muscular dystrophy as well as venous system abnormalities. Clinicians must keep in mind that this disease has a high risk of hemorrhage.
Collapse
|
30
|
Acetazolamide-Loaded Dynamic 7T MR Quantitative Susceptibility Mapping in Major Cerebral Artery Steno-Occlusive Disease: Comparison with PET. AJNR Am J Neuroradiol 2020; 41:785-791. [PMID: 32299799 DOI: 10.3174/ajnr.a6508] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 03/01/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Dynamic changes in cerebrovascular reactivity after acetazolamide administration vary markedly among patients with major cerebral arterial steno-occlusive disease. MR quantitative susceptibility mapping can dynamically quantify the cerebral magnetic susceptibility. The purpose of this study was to determine whether dynamic changes in susceptibility after administration of acetazolamide on 7T quantitative susceptibility mapping are associated with pre-existing states of CBV and the cerebral metabolic rate of oxygen in the cerebral hemispheres with major cerebral arterial steno-occlusive disease. MATERIALS AND METHODS Sixty-five patients underwent 7T MR imaging at baseline and at 5, 10, 15, and 20 minutes after acetazolamide administration. Differences between the susceptibility of venous structures and surrounding brain tissue were calculated in the quantitative susceptibility mapping images. Susceptibility differences at 5, 10, 15, and 20 minutes after acetazolamide administration relative to baseline were calculated in 97 cerebral hemispheres with major cerebral arterial steno-occlusive disease. CBV and the cerebral metabolic rate of oxygen were also calculated using 15O-gas PET in the resting state. RESULTS Dynamic changes of susceptibility after acetazolamide administration were classified into 3 patterns: abnormally increasing 5 or 10 minutes after acetazolamide administration; abnormally decreasing within 20 minutes after acetazolamide administration; and remaining unchanged after acetazolamide administration. CBV was significantly greater in the first pattern than in the latter 2. The cerebral metabolic rate of oxygen differed significantly in descending order from the first to middle to last pattern. CONCLUSIONS Dynamic changes of susceptibility after acetazolamide administration on 7T MR quantitative susceptibility mapping are associated with pre-existing states of CBV and the cerebral metabolic rate of oxygen in major cerebral arterial steno-occlusive disease.
Collapse
|
31
|
Patient-derived tumour model by new culture method leading to the precision medicine. Ann Oncol 2019. [DOI: 10.1093/annonc/mdz421.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
32
|
Multicenter phase II trial of axitinib monotherapy for advanced biliary tract cancer refractory to gemcitabine-based chemotherapy. Ann Oncol 2019. [DOI: 10.1093/annonc/mdz247.064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
33
|
P.344Assessment of longitudinal developmental milestones in Fukuyama congenital muscular dystrophy. Neuromuscul Disord 2019. [DOI: 10.1016/j.nmd.2019.06.458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
34
|
APPLICATION OF THE FOREST SHIELDING FACTOR TO THE MAXIMUM-LIKELIHOOD EXPECTATION MAXIMIZATION METHOD FOR AIRBORNE RADIATION MONITORING. RADIATION PROTECTION DOSIMETRY 2019; 184:400-404. [PMID: 31165889 DOI: 10.1093/rpd/ncz095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The maximum-likelihood expectation maximization (ML-EM) method is expected to improve the accuracy of airborne radiation monitoring using an unmanned aerial vehicle. The accuracy of the ML-EM method depends on various parameters, including detector efficiency, attenuation factor, and shielding factor. In this study, we evaluate the shielding factor of trees based on several field radiation measurements. From the actual measurement, the shielding factors were well correlated with the heights of the trees. The evaluated shielding factors were applied to the ML-EM method in conjunction with the measured data obtained from above the Fukushima forest. Compared with the conventional methods used for calculating the dose rate, the proposed method is found to be more reliable.
Collapse
|
35
|
E-POSTERS – MITOCHONDRIAL / METABOLIC DISEASES –CASE REPORTS. Neuromuscul Disord 2019. [DOI: 10.1016/j.nmd.2019.06.131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
36
|
Assessment of Changes of the Distance from Liver Surface to Isocenter during Proton Beam Treatment for Liver Cancer. Int J Radiat Oncol Biol Phys 2019. [DOI: 10.1016/j.ijrobp.2019.06.1986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
37
|
MON-PO405: Prolonging Factors of the Duration of Parenteral Nutrition in Patients Treated with Hematopoietic Stem Cell Transplantation. Clin Nutr 2019. [DOI: 10.1016/s0261-5614(19)32238-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
38
|
[A Case of Ascending Colon Cancer Probably Arising from a Diverticulum]. Gan To Kagaku Ryoho 2019; 46:1199-1201. [PMID: 31296831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
A 70's male was admitted to our hospital with complaints of anorexia and abdominal pain. CT showed thickening of the ascending colon. Colonoscopy revealed multiple diverticula of the ascending colon, but no tumor on the mucosa. The patient was diagnosed as a case of diverticulitis of the ascending colon and was advised laparoscopic ileocecal resection. The resected specimen showed wall thickening; however, no remarkable findings were observed, with the exception of multiple diverticula on the mucosal surface. Histological examination showed well-differentiated tubular adenocarcinoma extending into the serosa probably arising from the diverticulum. Chemotherapy was performed after surgery. The patient died due to peritoneal dissemination from the ascending colon cancer 14 months after surgery.
Collapse
|
39
|
Radiologic and Pathologic Features of the Transmantle Sign in Focal Cortical Dysplasia: The T1 Signal Is Useful for Differentiating Subtypes. AJNR Am J Neuroradiol 2019; 40:1060-1066. [PMID: 31097427 DOI: 10.3174/ajnr.a6067] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Accepted: 03/27/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE The transmantle sign is a characteristic MR imaging finding often seen in focal cortical dysplasia type IIb. The transmantle sign is typically hyperintense on T2WI and FLAIR and hypointense on T1WI. However, in some cases, it shows T1 high signal. We evaluated the imaging and pathologic findings to identify the causes of the T1 high signal in the transmantle sign. MATERIALS AND METHODS We retrospectively reviewed the preoperative imaging data of 141 consecutive patients with histologically proved focal cortical dysplasia. We selected 25 patients with focal cortical dysplasia with the transmantle sign and divided them into groups based on the pathologic focal cortical dysplasia subtype and T1 signal of the transmantle sign. We evaluated the clinical, radiologic, and pathologic findings, including the number of balloon cells and dysmorphic neurons and the severity of gliosis or calcifications and compared them among the groups. RESULTS Nine of the 25 patients had a T1-high-signal transmantle sign; the other 16 patients did not. All 9 patients with a T1-high-signal transmantle sign were diagnosed as type IIb (group A). Of the 16 patients with no T1-high-signal transmantle sign, 13 were diagnosed as having type IIb (group B), and the other 3 patients, as type IIa (group C). The number of balloon cells was significantly higher in group A than in the other groups, but there were no differences regarding dysmorphic neurons, the severity of gliosis, or calcifications. CONCLUSIONS Approximately 6% (9/141) of this patient series had a T1-high-signal transmantle sign, and all were type IIb. The signal may reflect a rich density of balloon cells. This finding could support the differentiation of subtypes, especially type IIb.
Collapse
|
40
|
Direct Measurement of the Cosmic-Ray Proton Spectrum from 50 GeV to 10 TeV with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2019; 122:181102. [PMID: 31144869 DOI: 10.1103/physrevlett.122.181102] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2018] [Revised: 03/03/2019] [Indexed: 06/09/2023]
Abstract
In this paper, we present the analysis and results of a direct measurement of the cosmic-ray proton spectrum with the CALET instrument onboard the International Space Station, including the detailed assessment of systematic uncertainties. The observation period used in this analysis is from October 13, 2015 to August 31, 2018 (1054 days). We have achieved the very wide energy range necessary to carry out measurements of the spectrum from 50 GeV to 10 TeV covering, for the first time in space, with a single instrument the whole energy interval previously investigated in most cases in separate subranges by magnetic spectrometers (BESS-TeV, PAMELA, and AMS-02) and calorimetric instruments (ATIC, CREAM, and NUCLEON). The observed spectrum is consistent with AMS-02 but extends to nearly an order of magnitude higher energy, showing a very smooth transition of the power-law spectral index from -2.81±0.03 (50-500 GeV) neglecting solar modulation effects (or -2.87±0.06 including solar modulation effects in the lower energy region) to -2.56±0.04 (1-10 TeV), thereby confirming the existence of spectral hardening and providing evidence of a deviation from a single power law by more than 3σ.
Collapse
|
41
|
Search for K_{L}→π^{0}νν[over ¯] and K_{L}→π^{0}X^{0} Decays at the J-PARC KOTO Experiment. PHYSICAL REVIEW LETTERS 2019; 122:021802. [PMID: 30720307 DOI: 10.1103/physrevlett.122.021802] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 12/14/2018] [Indexed: 06/09/2023]
Abstract
A search for the rare decay K_{L}→π^{0}νν[over ¯] was performed. With the data collected in 2015, corresponding to 2.2×10^{19} protons on target, a single event sensitivity of (1.30±0.01_{stat}±0.14_{syst})×10^{-9} was achieved and no candidate events were observed. We set an upper limit of 3.0×10^{-9} for the branching fraction of K_{L}→π^{0}νν[over ¯] at the 90% confidence level (C.L.), which improved the previous limit by almost an order of magnitude. An upper limit for K_{L}→π^{0}X^{0} was also set as 2.4×10^{-9} at the 90% C.L., where X^{0} is an invisible boson with a mass of 135 MeV/c^{2}.
Collapse
|
42
|
The CALorimetric Electron Telescope (CALET) on the International Space Station: Results from the First Two Years of Operation. EPJ WEB OF CONFERENCES 2019. [DOI: 10.1051/epjconf/201920813001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The CALorimetric Electron Telescope (CALET) space experiment, which has been developed by Japan in collaboration with Italy and the United States, is a high-energy astroparticle physics mission on the International Space Station (ISS). The primary goals of the CALET mission include investigation of possible nearby sources of high-energy electrons, detailed study of galactic cosmic-ray acceleration and propagation, and search for dark matter signatures. With a long-term observation onboard the ISS, the CALET experiment measures the flux of cosmic-ray electrons (including positrons) up to 20 TeV, gamma-rays to 10 TeV, and nuclei up to 1,000 TeV based on its charge separation capability from Z = 1 to 40. Since the start of science operation in mid-October, 2015, a continuous observation has been maintained without any major interruptions. The number of triggered events over 10 GeV is nearly 20 million per month. By using the data obtained during the first two-years, here we present a summary of the CALET observations: 1) Electron+positron energy spectrum, 2) Nuclei analysis, 3) Gamma-ray observation with a characterization of the on-orbit performance. The search results for the electromagnetic counterparts of LIGO/Virgo gravitational wave events are also discussed.
Collapse
|
43
|
Influence of loading rate and limb position on patellar tendon mechanical properties in vivo. Clin Biomech (Bristol, Avon) 2019; 61:52-57. [PMID: 30471637 DOI: 10.1016/j.clinbiomech.2018.11.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2018] [Revised: 11/04/2018] [Accepted: 11/09/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND The aims of this study were to clarify the changes of patellar tendon length during isometric knee joint extension and the double leg squat position using ultrasonography. METHODS The left legs of 17 healthy adults were investigated. Isometric knee extension motion was performed at three positions of knee flexion 30° (knee 30°), knee flexion 60° (knee 60°), knee flexion 90° (knee 90°), and at each limb position, 0% (0% peak torque (PT)), 40% (40% PT), 50% (50% PT), and 60% (60% PT) of the maximum knee joint extension torque were executed at random. Both double leg squat motions were randomly performed in three positions: hip flexion 30°, knee flexion 30°, ankle dorsiflexion 10° (squat 30°); hip joint flexion 60°, knee joint flexion 60°, ankle dorsiflexion 20° (squat 60°); and hip joint flexion 90°, knee joint flexion 90°, ankle dorsiflexion 30° (squat 90°). Ultrasonography was used to measure patellar tendon length. FINDINGS There were no significant changes in patellar tendon length and strain between knee flexion angles of 30°, 60°, and 90° in isometric knee joint extension and the double leg squat limb position. INTERPRETATION The loading rate and limb position do not appear to affect the length and strain of the patellar tendon.
Collapse
|
44
|
Hemodynamic response to orthostatic stress immediately after dialysis session in chronic hemodialysis patients. RENAL REPLACEMENT THERAPY 2018. [DOI: 10.1186/s41100-018-0189-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
|
45
|
A model based on a new inflammation–nutrition score and TNM stage for predicting overall survival of patients with colorectal cancer. Ann Oncol 2018. [DOI: 10.1093/annonc/mdy431.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
46
|
FSHD / OPMD / EDMD / DMI. Neuromuscul Disord 2018. [DOI: 10.1016/j.nmd.2018.06.415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
47
|
Predictive factors of outcome in patients with advanced biliary tract cancer receiving gemcitabine plus cisplatin as first-line chemotherapy. Ann Oncol 2018. [DOI: 10.1093/annonc/mdy282.150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
48
|
|
49
|
Multimessenger observations of a flaring blazar coincident with high-energy neutrino IceCube-170922A. Science 2018; 361:science.aat1378. [DOI: 10.1126/science.aat1378] [Citation(s) in RCA: 451] [Impact Index Per Article: 75.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Accepted: 06/08/2018] [Indexed: 11/02/2022]
Abstract
Previous detections of individual astrophysical sources of neutrinos are limited to the Sun and the supernova 1987A, whereas the origins of the diffuse flux of high-energy cosmic neutrinos remain unidentified. On 22 September 2017, we detected a high-energy neutrino, IceCube-170922A, with an energy of ~290 tera–electron volts. Its arrival direction was consistent with the location of a known γ-ray blazar, TXS 0506+056, observed to be in a flaring state. An extensive multiwavelength campaign followed, ranging from radio frequencies to γ-rays. These observations characterize the variability and energetics of the blazar and include the detection of TXS 0506+056 in very-high-energy γ-rays. This observation of a neutrino in spatial coincidence with a γ-ray–emitting blazar during an active phase suggests that blazars may be a source of high-energy neutrinos.
Collapse
|
50
|
Extended Measurement of the Cosmic-Ray Electron and Positron Spectrum from 11 GeV to 4.8 TeV with the Calorimetric Electron Telescope on the International Space Station. PHYSICAL REVIEW LETTERS 2018; 120:261102. [PMID: 30004739 DOI: 10.1103/physrevlett.120.261102] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2018] [Revised: 05/21/2018] [Indexed: 06/08/2023]
Abstract
Extended results on the cosmic-ray electron + positron spectrum from 11 GeV to 4.8 TeV are presented based on observations with the Calorimetric Electron Telescope (CALET) on the International Space Station utilizing the data up to November 2017. The analysis uses the full detector acceptance at high energies, approximately doubling the statistics compared to the previous result. CALET is an all-calorimetric instrument with a total thickness of 30 X_{0} at normal incidence and fine imaging capability, designed to achieve large proton rejection and excellent energy resolution well into the TeV energy region. The observed energy spectrum in the region below 1 TeV shows good agreement with Alpha Magnetic Spectrometer (AMS-02) data. In the energy region below ∼300 GeV, CALET's spectral index is found to be consistent with the AMS-02, Fermi Large Area Telescope (Fermi-LAT), and Dark Matter Particle Explorer (DAMPE), while from 300 to 600 GeV the spectrum is significantly softer than the spectra from the latter two experiments. The absolute flux of CALET is consistent with other experiments at around a few tens of GeV. However, it is lower than those of DAMPE and Fermi-LAT with the difference increasing up to several hundred GeV. The observed energy spectrum above ∼1 TeV suggests a flux suppression consistent within the errors with the results of DAMPE, while CALET does not observe any significant evidence for a narrow spectral feature in the energy region around 1.4 TeV. Our measured all-electron flux, including statistical errors and a detailed breakdown of the systematic errors, is tabulated in the Supplemental Material in order to allow more refined spectral analyses based on our data.
Collapse
|